64-445 - HARMONY GROVE ROAD - CONSERVATION COMMISSION C DEP 64- Plans' 4-Plans --- - - - - - - - -- - - - - r YihVMon N Consulting Engineers GENERAL 53 Southampton Road G1 Structural work shall conform to Massachusetts State Building Code, latest edition, Westfield, Massachusetts including most recent addenda, and Contract Documents. In case of conflict, most I (413) 562-1600 stringent requirement shall govern. 8" CMU INFILL — G2 Contractor shall verif and coordinate dimensions related to this project. I www.tighebond.com Y P I B TYP BOTH ENDS ( ) G3 Steel plates shall conform to ASTM A572 Grade B - 50 KSI. G4 All steel exposed to weather shall be hot dipped galvanized in conformance with REINFORCED - I I 2- 5 TOP ASTM A123. CONCRETE BEAM I # • (TYP) � I I FIN. GRADE L 14 I I I I I I p I I #4 TiES AT 12" OC REINFORCEMENT I I I I I O w Rt Detailing, fabrication, and erection of reinforcement, unless otherwise noted, shall I I I ( I to " " 5 HOOKED BARS DRILLED conform to ACI Building Code Requirements for Reinforced Concrete (ACI 318) — � iI I I I 'A" THICK GALVANIZED I � o I I & EPDXY GROUTED INTO and ACI "Manual of Standard Practice for Detailing Reinforced Concrete Structures �T I II II I I I STEEL DIAMOND PLATE I OI I I I I EXISTING CONCRETE WALL �`N 6F MAs (ACI 315)", latest edition. �/ I I I II II, I I COVER 2 PIECES (FIELDI N (1 PER END EACH BEAM, TYP) ��" S90 I I I ULJI CAULK JOINT BETWEEN I o a, oa TODD M.R2t Steel reinforcement ,unless otherwise shown shall conform to ASTM A615 Grade 60 I I I } � eaowN�� _ PLATES) I SANITARYminimum (yield strength 60,000 psi). 1z , .I O No.37634 R3 Provide and schedule on shop drawings, all necessary,accessories to hold reinforcement A I I I ;� 1 2 90 aFsecurely in position: minimum requirements shall be: high chairs, 4'-0" on center, #5 _ 1 Q toEX/SANG CONCRETE SLABsupport bar for high chairs, slab bolsters, S-6" on center, all wire chairs and bolsters to I be plastic tipped. - - - -- - -� 6. ($*7 R4 The concrete protective covering for reinforcement shall be 2" clear to beam stirrups. T 2—#7 BOTTOM, HOOKED n EXlSANG CONCRETE WALL R5 Where reinforcement is not shown on drawings, provide reinforcement In accordance I I . with applicable typical details or similar to that shown for most nearly similar situations, 4 HOOKED BARS AT 24" OC as determined by the Engineer. In no case shall reinforcement be less than minimum 5'-0" S-4" �C = STRUCTURE 'M' DRILLED & EPDXY GROUTED INTO reinforcement permitted by the applicable codes. " EXISTING CONCRETE 4 MIN. EMBED R6 Where reinforcement is called for in section, reinforcement is considered typical EXISTING CMU WALLS OVER SLAB wherever the section applies. I REMOVED PRIOR TO PLACEMENT OF R7 Reinforcement coupler splices shall be mechanical devices capable of transmitting the NEW REINFORCED CONC BEAMS �a��e OF Ifgsf ultimate tensile and compressive strength of the bar. PLAN o�� qo: R8 Installation of reinforcement shall be completed at least 24 hours prior to scheduled SECTION B POPLEARQZYK 1/4"=1=_0" CIVIL concrete placement. Notify Engineer of completion at least 24 hours prior to scheduled No.374M ti completion of placement or reinforcement. R9 Reinforcement shall be set before placing concrete. Setting any reinforcement mss/oNAL EV' Into wet concrete is prohibited. 0 HARMONY GROVE ROAD G lo-7 CONCRETE L§" THICK GALVANIZED STEEL DIAMOND 2'X5' HATCH GRANITE CURB PLATE (2 PIECES). TOP OF PLATES 67 Concrete work shall conform to the latest editions of the building code requirements for _ MANHOLE FLUSH WITH TOP OF SIDEWALK. reinforced concrete (ACI 318), and specifications for structural concrete for building 1 S" 2'-0" 8" (ACI 301). %NDIA COUNTERSUNK 304 S.S. P P I BOLTS AT•18 OC (ANTI-SIEZE DROP—IN N IN HDI—L T 1 S.S. C2 Concrete shall be controlled concrete„ proportioned, mixed and laced under the ^ supervision of on approved concrete testing agency or the Engineer. COMPOUND APPLIED PRIOR TO DROP-IN INSERTS AT IN OC & INSTALLATION, TYP 1 AT EA. END (3Y'i" MIN. EMBED) C3 Concrete shall be normal weight concrete and shall have a compressive strength of 4000 STRUCTURE M' ) psi at 28 days, unless otherwise noted. and shall be air entrained. FIN. GRADE C4 Exposed edges of concrete elements shall have chamfered corners. 7s" /N7ERCEPTOR \ ` 2:- 5 ( II I 2 C5 No concrete shall be placed In water or on frozen ground. 1 a #4 12" a Upgrade of 8" CMU INFILL I . . AT 12" OC W STRUCTURE M BEYOND m Peabody Metering #4 TiES (GROUT CELLS o AT 12" OC ' Facilities N BAR SIZE. DEVELOPMENT SPLICE LENGTH z— I I 2— fi DESIGNATION LENGTH (INCHES) EL 252 (INCHES) ENGLISH METRIC CLASS B CLASS B EL 0.75 00 South Essex Ld TOP BARS Sewerage District #3 #10 15 19 25 #4 HOOKED BARS AT 24" OC n } 12" ts'-ou 12" DRILLED & EPDXY GROUTED INTO II EX/SANG CONCRETE SLAB Contract NO. �6'2 #4 #13 19 25 33 EXISTING• CONCRETE (4" MIN. EMBED) `I BARS DRILLED & EPDXY GROUTED SECTION A INTO EXISTING CONCRETE WALL #5 #16 24 31 40 Salem, Massachusetts 1/4"=1'-0" - GROUT PROVIDED TO SMOOTH (2 AT EACH END WALL, TYP) ROUGHENED CONCRETE SURFACES #6 #19 29 37 48 AROUND OPENING (SIKADUR 45 EPOCEM OR EQUAL) #7 #22 42 54 70 DETAIL 1 #8 #25 48 62 81 3'-4" #9 #29 54 70 91 PLATE #10 #32 61 79 103 lh"DIA LIFTING HOLE WITH o0 I L4"DIA 304 S.S. NUT r WWELDED ELD OF 4O UNDERSIDE i I -H REBAR SPLICE LENGTH SCHEDULE I I 'A N "DIA COUNTERSUNK 304 S.S. BOLT AT EACH HOLE (ANTI-SIEZE COMPOUND I I ao g o NOTES: 1. IF CLEAR SPACING BETWEEN THE REBARS IS LESS THAN THREE BAR APPLIED PRIOR TO I I -{ I 1. IMPROVEMENTS SHOWN ON THIS SHEET ADDED IN ACCORDANCE WITH DIAMETERS, OR IF COVER IS LESS THAN TWO BAR DIAMETERS, INSTALLATION) I I 00 a N CHANGE ORDER NO. 1. INCREASE THE SPLICE LENGTH BY AN ADDITIONAL 507. 4-1h"DIA 304 S.S. EYE I I I 2. THE MINIMUM REBAR SPLICE LENGTH SCHEDULE IS BASED ON BOLTS INSTALLED FOR USE I I ;H 1 o Mac Date aRewrPlans F'c= 4,000 PSI AND Fy= 60,000- PSI. ADJUST FOR OTHER WHEN REMOVING COVER I I te Descrlp0on STRENGTHS USING ACI-318. PLATES I I 1 PROJECT NO: S152612 3. FOR HORIZONTAL REINFORCEMENT SO PLACED THAT MORE THAN I N FILE: S15261SHEET6 12 INCHES OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW, L J co DRAWN BY: RWK INCREASE THE DEVELOPMENT LENGTH BY AN ADDITIONAL 30% CHECKED: MPM,DJP 4. WHEN BARS OF DIFFERENT SIZE ARE LAP SPLICED, THE SPLICE LENGTH APPROVED BY: TMB SHALL BE THE LARGER OF EITHER THE DEVELOPMENT LENGTH OF THE 20" 20^ STRUCTURE 'M' STRUCTURAL LARGER BAR OR THE SPLICE LENGTH OF THE SMALLER BAR. _ IMPROVEMENTS - PLAN, PLAN-COVER PLATES SECTIONS, DETAIL, AND NOTES RECORD PLAN SCALE: AS SHOWN THIS RECORD PLAN WAS PREPARED BASED ON LIMITED INFORMATION GATHERED DURING CONSTRUCTION OF THE PROJECT AND INDICATES ONLY SIGNIFICANT CHANGES MADE FROM THE DESIGN PLANS DURING CONSTRUCTION. SHEET 6 7/2e/os __ — ........... -- Tighe&Bond _. P NEIL T7'10 5HL'N2E r7LA3 ��$,� 0SCD ST•A'-L ARW4a ,���� ���,��$AR°.r�>xb Consulting Engineers B ` vHG-,.1-L`. oR A"PRAc, rgaujAI , tTyPi 53 Southampton Road �---1 '9^I. 1 S•1 Y"X w1 -7 LI } B�["w,•I••YUirbR O AND I I £L.ILTS3 r1 FaAT ERPOS['b RODS AND I 511 '.. „ 3_ WAAE.7N BURLAP. j EL.18::Tt_ q_n-gmt(cyR) Westfield, IIb•9^ ,no � �- � � � 6 _ I• •anm s.c�YY) (4 Massachusetts3) 5 �• -- - \ b d I I .�i B PIAN K8 �� 6�0 I I C---------J� gEvr.T6'"� ..1Wuf .4.b2 A _ .�-._._._ --- www.tighe on .com I I R.C.plp! -•-- ST 8 4f tD fTt F• - y ' '' TIMBER BIILTIHEAOB O I *, Y'Oa T' ^ .... IE1{15.Ca..PEABODY .__ ___ "5 _ ST4"IgoaTi�WI ,: .. SE.E"NOTE�kLTFRq 'J/ �\ j B Q p r T I ICBMs& 4 CRIT _ _ - -- ] I ,. , - L FRT A• 1•_rd � iI P cpeMBc¢ _ G - I I z;a`CRQ35 �\ A ^ r-----�-'-- / o R 0P c { I y:4 ^I 4 s f v STIn-2 ? 4 c I BRAC I G sxls t.pipe ,h _--- -- � � ' •} @ \ •'\ -REMOVABLE n -_ I. , -('I I I I i n I k'LAElL .. :5 N ,® _ NV \ `\v / CONC.SLAB t.. n >{J I^ I - _.�. ; � BOLT w,' t R � \ " _j n . INV.:.tL:l I- ,` il` f I n -.�....__.. . .I a -J f �r--- I . _$ 11.814•SIGBS) .. OOTLE� ,_r. r .t,.t,2.5E T . L:¢.9 ; } / ¢ 1 y-i4v.e :34 u I� Y4Y TI -- - ST4:180.1.5.502 i --- - ,�.,� I (I 'I n,u) •,p._, --- I 3 STEEL BELL R81,G \ / . . - '•"�::.".,u.: _. .L_. ter•:: . -*4f&9 'W/.ANCHORS TO SU1T S^REMOV45Le COgr-.- JT. ErS'G C04C.GRAU1_ ' 8>.'. - �'dIDE. (TYP AI_L R.C"PIPE). SEALER / REN.O1tAEiLJ<. `g8v.1:7K Qr I " Si O•-- �a�9 o•F• /� i SP SE.W+ -T B `tN Of MA R.c.PIPR �" NREADBD-INSERTS/ � � ��-. S _2StP'_'_Pt�li . w/SaEu.RxI+c LG.s� � / ,/ --- y\�P y SeALE. .I-A•' itO.C•.^THREADONEJ .�__ . 'NOTE: ! J/ a •r,10" r -_ - Or TODD M. END ONLY. --- £L.-5.00 TIMISF9 BULKHEAD'S TO BE 3^e8 y` V SF BROWN rn --- TONGUE:AICD GROOVE..PLANKS REMoveBLE SLABS 2�� G {O I V m Lo Td.Td.FIT:TH5TDE:THE o SANITARY - I \ 1 SCALEa/d-•t=o^ y.$ " NG.37634 t" 4'.VJD':'7E."�D:I A...OERNIN6.9_JN . T y} [� N. CROSS 5 SRAGE'W�VKAIL'AE.VERTHE 5TRI SCAL ex4 Ore:[/V6- •' �� L- 1 -7� oP.NE W'e.c.p1p! EL .-6•TS IP f, 9fCISTERE� E! AIFTG.MOOK fTv - 0 E X0440"TC.C. AND.SMALL A OPD AT .2•[5 FxYi1C.CRA04 EL.16:03' � L 9 ILC" T ENING --- - .' - •o iTYP pus7c.STRUCTURE. W4LL - C' I I. s/E"sFL.pLeTe LI EL lits± scALe R/8"=1=0' 9.1 E I o 6 18 0 SESD MAMNOLE A L_� MOORBCL•r(Yllk,, j'x3°aLm9? �COVER CFRa}/E I . ,T - , T SEL V_TAILB TN155FI'. ; _ , +f4m q-t.0 ,TYR) -rauLK•OGRNr4G5 VAlFwAY wfJllTE: FILL REuaiupEROF _ r._ -` C1JIE,L O . -STEL SLEEETHOVGH 1NOTPAUR :P .W 2-x5' -41 Sw7m, Cw ISTG:pE600? ACR OfC \ J--.' :QB VxALL TO SUIT 4#'C.L OVTLR I IW tR[f IIILSFL)IS3T- PI Pe.CAULK AS DIRECTED t=0".WALL (. ] 9�L1-. - __ 94.89=•F•< YP.) BY.T.H4 EN'GINEeR.. . L._;_. n,.._. , ! . ._80L_T5 W/'NASM439 Ike "_--�IkIJ'I I _- R-0d-`,.I_•wt.I- { iI - _- - IIII , III r2V. iIr"5IT16y9P,)O.P II•lls) I•1�.':l•e'a - - \ 1� 418'STL.. i /✓` , ( / "`.I �/�� x%` \O\/'I,' � OAAn.p IPE.BPIdEG* .... A_n,,txt To 1---7t4 a RAKs.4�l a f.. �. 1 1 q' ' I ¢ STEEL. ELL -�EX19T. TOP 'W/ARCUQRS 1050,7 1 �n `ZN OF MA AA S RL,0 .75 It L-6 C LL.S kGPI t . S5T6 I J. 1 •e' POPIEL�ARCZYK 0 s o B. �' 1`\ I ys• / °•V� ( jy CIVIL --, I `AXIST. 46 C.-,.OUTLET I 4r'! xJ) No.97491 Et. I - -- -... I ,, .><ROFA GREA3R4GR17 ____ _ " -, IAV,EL.694 111 / `FdNv i34 9 9 O Ab,� pl''"1' _ S9 �Q f-. ..1 CJiAMRVRC.E . REMAIN ! M .y nwdh °,rf, 1 IN SERVICE � ' �'✓� s. I -'tMl)nl.� --- _- �_---1 11 �II I / /`tel sib A E�6 E[i9T. CDNC.CRADLE r_ ___ 1--'4x4./°2 LS.Y�ALWLII2E'-S S�p- \ �.h10P PL ANION" `'-3/4' 'CAIVA)112ED 441CN0¢` \/ / ESO LTS.W/w48.MCrL.tm..l2" o..G.(4-sq.EB) ALL 6EXUrl AS NOT ---- /I 3CAk1,{i4.1'"O•' 9•I - 6�4"-ROO'(4-REQrD) d5(J g EXCEPT AS gOTED �Y /v $'s Lie yi p S E/tO I.1 2 . ,••tia4gTv gcALe:ttf".Y-o' S.2 _.�E TAIL OF ROOF CO,SCT3OOID AIJCNOO RANK�RODV �tie NOTES: PL .1N-S:CTiON scaLE: aye°�Iao• 1. DETAILS ARE HALF OF ORIGINAL SCALE SHOWN. STRUCTURE M 2. DETAILS ARE FROM CONSTRUCTION OF STRUCTURES M AND N IN 1971 AND ARE BEING PROVIDED BECAUSE THE STRUCTURE N SCALE - SEE NOTE 1 CONTRACTOR WILL NEED TO PROVIDE ISOLATION OF THE WORK AREA IN! STRUCTURE M, INSTALL A SLIDE GATE IN SCALE - SEE NOTE 1 STRUCTURE M, AND INSTALL A NEW PIPE THROUGH THE STRUCTURE M WALL. IN ADDITION, THE CONTRACTOR MAY Upgrade of NEED TO ENTER STRUCTURE N AS PART OF THE FLOW DIVERSION REQUIRED AROUND THE METERING CHAMBER. THE CONTRACTOR WILL BE RESPONSIBLE FOR INSPECTING THE STRUCTURES AT THE BEGINNING OF THE PROJECT TO Peabody Metering IDENTIFY CHANGES MADE SINCE THE STRUCTURES WERE CONSTRUCTED IN 1971. 3. DRAWINGS ABOVE DO NOT REFLECT AS-BUILT CONDITIONS OF STRUCTURE M IDENTIFIED DURING CONSTRUCTION, Facilities WHICH ARE SHOWN ON SHEETS 3 AND 4. STRUCTURAL NOTES: South Essex GENERAL REINFORCEMENT Sewerage District G1 CONTRACTOR SHALL INSPECT EXISTING STRUCTURE M PRIOR TO CUTTING WALL. R1 DETAILING, FABRICATION, AND ERECTION OF REINFORCEMENT, UNLESS OTHERWISE: Contract No. 0V-2 TO IDENTIFY ANY FEATURES THAT MAY IMPACT THE PROPOSED OPENING NOTED, SHALL CONFORM TO ACI "BUILDING CODE REQUIREMENTS FOR REINFORCED SIZE/LOCATION. CONCRETE (ACI 318)" AND ACI "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI 315)", LATEST EDITION. Salem, Massachusetts G2 THE ENGINEER SHALL HAVE THE RIGHT TO POSTPONE OR STOP CONCRETE OPERATIONS WHEN IN HIS R2 STEEL REINFORCEMENT, UNLESS OTHERWISE SHOWN, SHALL CONFORM TO ASTM JUDGMENT, REINFORCEMENT AND EMBEDDED ITEM INSTALLATION HAS NOT BEEN PROPERLY A615 GRADE 60 MINIMUM (YIELD STRENGTH - 60,000 PSI). COMPLETED OR THE QUALITY OF CONSTRUCTION WILL IMPAIR STRENGTH AND DURABILITY OR DESIRED FINISHED PRODUCT. COSTS ARISING FROM DELAYS DUE TO NONCOMPLIANCE WILL NOT BE R3 WHERE REINFORCEMENT IS NOT SHOWN ON DRAWINGS, PROVIDE REINFORCEMENT IN CONSIDERED. ACCORDANCE WITH APPLICABLE TYPICAL DETAILS OR SIMILAR TO THAT SHOWN FOR MOST NEARLY SIMILAR SITUATIONS, AS DETERMINED BY THE ENGINEER. G3 GROUT SHALL BE A READY-TO-USE, NON-METALLIC, NON-SHRINK AGGREGATE PRODUCT REQUIRING ONLY THE ADDITION OF WATER AT THE JOB SITE. GROUT SHALL BE AS MANUFACTURED BY FIVE R4 WHERE REINFORCEMENT IS CALLED FOR IN SECTION, REINFORCEMENT IS STAR PRODUCTS, INC.; EUCLID CHEMICAL COMPANY; MASTER BUILDERS; OR APPROVED EQUAL. CONSIDERED TYPICAL WHEREVER THE SECTION APPLIES. GROUT SHALL BE EASILY WORKABLE AND SHALL HAVE NO DRYING SHRINKAGE AT ANY AGE. R5 INSTALLAT10N OF REINFORCEMENT SHALL BE COMPLETED AT LEAST 24 HOURS PRIOR TO COMPRESSIVE STRENGTH OF GROUT (2 INCH BY 2 INCH CUBES) SHALL NOT BE LESS THAN 5000 SCHEDULED) CONCRETE PLACEMENT. NOTIFY ENGINEER OF COMPLETION AT LEAST 24 PSI AT 7 DAYS, AND 7500 PSI AT 28 DAYS. HOURS PRIOR TO SCHEDULED COMPLETION OF PLACEMENT OF REINFORCEMENT. R6 REINFORCEMENT SHALL BE SET BEFORE PLACING CONCRETE. SETTING ANY REINFORCEMENT INTO WET CONCRETE IS PROHIBITED. R7 REINFORCEMENT SHALL BE ACCURATELY PLACED IN ACCORDANCE WITH CONTRACT DOCUMENTS AND SHALL BE IFIRMLY SECURED IN POSITION BY WIRE TIES, CHAIRS, SPACERS, AND HANGERS, EACH OF TYPE APPROVED BY THE ENGINEER. FOR SLABS, GRADE BEAMS, ETC. WHERE CONCRETE IS POURED ON GRADE, USE ADDITIONAL SETUP BARS AND CONCRETE BRICK TO PROVIDE REQUIRED COVER OVER REINFORCEMENT. R8 BEFORE CONCRETE IS PLACED, RENFORCEMENT SHALL BE FREE OF EXCESSIVE RUST, DIRT, OIL, t o7/06 Record Plans SCALE OR OTHER FOREIGN MATTER THAT WILL DESTROY OR REDUCE BOND REQUIREMENTS. REINFORCEMENT EXPECTED TO BE EXPOSED TO WEATHER FOR A CONSIDERABLE LENGTH OF TIME Mark I Date IDescription SHALL BE (PAINTED WITH A HEAVY COAT OF CEMENT GROUT. PROTECT STORED MATERIALS SO AS PROJECT NO: 5152612 NOT TO BEND OR DISTORT BARS IN ANY WAY. BARS THAT BECOME DAMAGED WILL BE REJECTED. FILE: SHEETS R9 WHERE REINFORCING STEEL BARS ARE CALLED FOR TO BE EPDXY GROUTED INTO EXISTING DRAWN BY: TMF CONCRETE, THE SYSTEM SHALL CONFORM TO HILT] HVA ADHESIVE OR HIT C-100 ANCHORING CHECKED: MPM, DJP SYSTEMS, POWERS, POWER-FAST SYSTEM, OR APPROVED EQUAL. ANCHORAGE SHALL DEVELOP AN APPROVED BY: TMB ALLOWABLE BOND STRENGTH EQUAL TO 24,000 PSI TIMES THE AREA OF THE BAR, OR AN ULTIMATE STRENGTH EQUAL TO THE TENSILE STRENGTH OF THE BAR. STRUCTURAL NOTES AND STRUCTURES M AND N R10 THE MINIMUM CONCRETE COVER OVER REINFORCING SHALL BE Y, TYPICAL. REINFORCING BARS RECORD PLAN REFERENCE DETAILS SHALL EXTEND A MINIMUM OF 6" INTO NEW CONCRETE/GROUT. THIS RECORD PLAN WAS PREPARED BASED ON LIMITED INFORMATION SCALE: AS SHOWN GATHERED DURING CONSTRUCTION OF THE PROJECT AND INDICATES ONLY SIGNIFICANT CHANGES MADE FROM THE DESIGN PLANS DURING CONSTRUCTION. SHEET 5 7/25/08 4" DRAIN WITH FLANGED PLUG VALVE AT I Tighe(,�[Bond 36" COUPLING BOTTOM OF PIPE-HANDWHEEL OPERATOR EXISTING LOCATED AT EDGE OF PIPE I ELECTRICAL NOTES: Consulting ErigineerS STEEL SLEEVE COUPLING INSTALLED 36" DI PIPE O I 1. EXISTING SIGNAL/CONTROL AND GROUND WIRING RECONNECTED TO NEW ELECTROMAGNETIC FLOW SENSORS. 53 Southampton Road UNDER CHANGE ORDER NO. 11 WATERSTOPS AROUND PERIMETER OF PIPE I Westfield, Massachusetts 36" MJxMJ GATE VALVE AND WALL OPENING-ANNULAR SPACE ' GENERAL NOTES (413) 562-1600 36" DI PIPE AND BOX FILLED HATH NON-SHRINK GROUT I 1. NEW BURIED GATE VALVE RESTRAINED WITH RETAINER GLANDS. SEE SPECIFICATION SECTION 02514. WWWtigheBond.com 4't LG 10" DEWATERING PIPE LEFT IN' PLACE WITH 1958 FRAME AND COVER I 2. CONTRACTOR ARRANGED FOR A MANUFACTURER'S SERVICE TECHNICIAN TO INSPECT AND TEST NEW (PROVIDED BY THE DISTRICT) FOR I METER ONCE IT WAS REINSTALLED. REFER TO SPECIFICATION SEC71ON 13420. FUTURE USE NEW 36" MAGNETIC STRUCTURE M I 3. WASTEWATER BYPASS OF THE METERING CHAMBER WAS MAINTAINED BY THE CONTRACTOR DURING FLOW METER I CONSTRUCTION UNTIL ALL PIPING, FLOW METER, WIRING AND ALL OTHER RELATED IMPROVEMENTS SEE NOTE 6 WERE COMPLETED AND APPROVED BY THE ENGINEER. SLIDE GATE 4. CONTRACTOR CORED OPENING FOR NEW 36" DI PIPE ALONG SAME CENTERLINE AS EXISTING 24" DI PIPE IN THE METERING CHAMBER, AS SHOWN. CONTRACTOR SAW-CUT OPENING FOR NEW 36" DI PIPE ABOVE EXISTING 36" DI PIPE OPENING IN STRUCTURE M AND REPAIRED CONCRETE WITH A - - - - — - _ — - - _- _ _ _ — _ i - _ _ — _ — A NON-SHRINK GROUT, AS SHOWN. ' N Of 5. FOR INFORMATION REGARDING STRUCTURES M AND N, SEE SHEET 5. o� TODD M. �y 12" I 6. A NEW MAGNETIC FLOW METER WAS INSTALLED TO REPLACE THE EXISTING MAGNETIC FLOW METER. o SANII ARY N� I I I REFER TO CHANGE ORDER NO. 3. a No.37 + h ❑ ------- q°�,���ISTeRE� COUPLING STEEL ANGLES IN TALLED I 1 G uENnlanoN 36" TRANSITION TO TEMPORARILY ISOLATE 6•/$•�7 FAN ABOVE METERING CHAMB R-LEFT BRICK CHIMNEY 36" SS IN PLACE FOR FUTURE " OFFSET PIPE DISTRICT USE 2 OPERATING NUT 2x5' ALUM PLATE HATCH N FOUNDATION FROM DECOMMISSIONED FACILITY I EL 15.501 EL 15.50± t SAMPLE PUMP AND GRINDER 78" RC INTERCEPTING SEWER--------'e EL 12.67 BASEMENT �ZN OF M,qs FFE 3.5 B ��a 1P I - Or DAVID J. yG 36" SS SLIDE - POPIELAROZYK GATE AND FRAME cnnL .. - 12•' Je No.374M I STRUCTURE M V �SIO� G ¢ EL 3_.25 I ` VENI7LAT/ON FAN ABOVE I - I - - INV EL 1.75 --- -- - - EL 0.75 ; ' SS OFFSET PIPE <` BASEMENT PLAN SLIDE GATEUpgrade of ELEVATION '00B DETAIL 1 Peabody Metering 1"=5' _ 1"=5' - Facilities NEW STRUCTURE M ACCESS South Essex INSTALLED UNDER CHANGE ORDER FENCE NO. 1-SEE SHEET 6 Sewerage District GRANITE CURB Contract 1 o. 06-2 5'x4' HATCH MANHOLE i5,X5' HATCH 2x5' HATCH MANHOLE l� EL 16.50 HARMONY _______ BITUARNO S GROVE ROAD r BITUMINOUS DRIVEWAY WALK 3 WATERSTOP WELDED TO EL 1s.s CONTINUOUS WATERSTOP AT PERIMETER OF SAW-CUT 12 PIPE PERIMETER (3/8 MIN. Salem, Massachusetts r i i i OPENING. THICKNESS) " DECOMMISSIONED GREASE i ' I EL 12.67 AND GRIT FACILITY 8" THICK CONCRETE SLAB —Jj_ • I 48" DIr METER NON-SHRINK GROUT (TYP) CORED iOPENIN 78" INTERCEPTOR EL 7.33 I I STRUCTURE M EL 3.25 METERING 36" DI PIPE T 2" i _ — CHAMBER -� I �"L 3.25 DRILLEE & EPDXIED #3 DOWELS EL 2.52 9" O.C. AT BOTTOM AND. #3 DOWELS EL 1.50 �`�,_ % _ _ _ _ _ _�r ® 12" O.C. TOP AND SIDES — - — - — - - — - EL o.75 (3b8" MIN EMBEDMENT) rz STRUCTURE M 36" SS SLIDE GATE ANC) EL —3.17 i FRAME i STEEL ANGLES NEW 36" SS OFFSET ' SEE DETAIL 1 INSTALLED TO TEMPORARILY PIPE WITH 3" t o7loa Record Plans NEW MAGNETIC FLOW - ------ - ELECTRICAL NOTES: I V` oil SUMP PUMP I Consulting Engineers 1. EXISTING SIGNAL/CONTROL AND GROUND WIRING DISCONNECTED FROM EXISTING ELECTROMAGNETIC FLOW SENSOR. 53 Southampton Road Westfield, Massachusetts F PIP 2. LOOSE CABLE ASSEMBLY STRAPPED TO EXISTING CONDUIT FOR PRO CTION DURING CONSTRUCTION. LENGTH 0 E TE DU G REMOVED COORDINATED WITH NEW ' (413) 562-1600 WORK SHOWN ON SHEET 4 /y Www.fighebOnd.COm 78" RC INTERCEPTING SEWER (BYPASS) I BELOW GROUND GENERAL NOTES: STRUCTURE FROM B DECOMMlSS/ONED. FACILITY w C I 1. CONTRACTOR REMOVED, CLEANED AND REVIEWED CONDITION OF EXISTING MAGNETIC FLOW TEST PIT EXCAVATED TO _ srRucruR� M METER. o VERIFY DISTANCE BETWEEN STRUCTURES 2. CONTRACTOR ARRANGED FOR A MANUFACTURER'S SERVICE TECHNICIAN TO INSPECT AND TEST SAMPLING PORT THE NEW METER FOR DEFECTS AND CONFIRMED METER ACCURACY IMMEDIATELY FOLLOWING 5x4' HATCH ABOVE ACC's PORT WITH s" PIPE INSTALLATION AND REACTIVATION OF THE SANITARY FLOWS THROUGH THE METERING CHAMBER ' OPENING IN CONCR CUT PIPING. FOR INSTAL ATION F NEW L 00 55 P 3. FOR INFORMATION REGARDING THE STRUCTURES N AND M, SEE SHEET 5. A i i i i i i i _ _ g PIPE i - . 4. A NEW MAGNETIC FLOW METER WAS INSTALLED TO REPLACE THE EXISTING MAGNETIC FLOW 36"C/ I I I I I I - +I, METER. REFER TO CHANGE ORDER NO. 3. �P`�N OF Mgffq - - -=E3a13_3"f oar' TODD M. �yG 11 TI ! OPENING . BROWN N ---- ---- o SANITARY . I ❑ LADDER No.37634 VVENTILATION FAN I 36"x24" REDUCER I 9ofFSF /sit% W C METERING ABOVE " BRICK CHIMNEY PLATE GUIDES - I - FACILITY REMOVED AND B DISPOSED OF 5'x5' HATCH : I EL 16.50 EL 15.50 IC W METER SAMPLE PUMP SEENETGENERAL NOTES 1-4 AND GRINDER BASEMENT FFE 3.5 FOUNDA77ON FROM DECOMMISSIONED FACILITYI oVA of Af yrcy DAVID J. G m 78" RC INTERCEPT/NG SEWER POPIELARCZYK I o CIVIL J.o No.374M DECOMMISSIONEDAND GRITFACILI Y SE CHAMBER METERING METRASEMENTING S TA TION sit ON SS1ON VENTILATION FAN BASEMENT FFE 3.5 ABOVE tvli8�o7 PW PW I 9 EL 1.50 INV EL 0.00 LADDER BASEMENT PLAN EL -3.17 1"=5' Upgrade of Peabody Metering Facilities SECTION e 1"=5 - 2' WIDE CONCRETE OPENING South ESS@X ADDITIONAL CONCRETE CUT INTO ROOF SLAB AS PART DEMOLITION WORK COMPLETED FENCE OF CHANGE ORDER NO. 1 UNDER CHANGE ORDER NO. 1 GRANITE CURB Sewerage District 5'x4" HATCH MANHOLE �I 5'x5' HATCH 2'x5' ALUM MANHOLE n �+ n' (� J1_ EL 16.50 BITUMINOUS PLAIT£ Contract 1 o. 06-2 _-__--_-_ HATCH BITUMINOUS HARMONY EL 15.50 - - DRIVEWAY WALK GROVE' ROAD Salem, Massachusetts. DECOMMISSIONED GREASE i i i EL 12.67 AND GRIT FACILITY i 8" THICK " CONCRETE SLAB 2'x5' HATCH 4"X16" STELEL £L 15.501 36" Cl 3s" D/ REMOVED ; SHELF EL 8.85 78" INTERCEPTOR EL 7.33 CHANN 14" STRUCTURE M 24 TO 36" TAP (RED P/PI,' EL 5.17 SEE SHEET 5 £L 12.6 71 METERING , FOR DETAILS CHAMBER C.I. WALL , SLEEVE rREMOVED AND STRUCTURE M \ 1 DISPOSED OF PLATE EL 2.52 g EL 1.50 GUIDES - — - — - - - - — - - — - — - - OPENING CUT IN CONCRETE PE I EL 0.75 FOR INSTALLATION OF NEW I I . 36" SS PIPE EL 6.38 - SAW-CUT OPENING IN , t16 CONCRETE FOR INSTALLATION; EL -3.17 f OF PROPOSED 36" SS PIPE i i 4" DRAIN ------ ---------------j 1 07/08 Record Plans EXISTING CONCRETE I PIPE SUPPORT _ i Mark Date Descripfion j (TYP OF 3) MAGNETIC FLOW METER - i j FOUNDATION FROM SEE GENERAL NOTES 1-4 I DECOMMISSIONED FACILITY PROJECT NO: S152612 L----------------------------------------------------------------------------- ---------------------L-- FILE: SHEET3 ' 36"x24' REDUCER ADDITIONAL CONCRETE DRAWN BY: TMF DEMOLITION WORK COMPLETED CHECKED: MPM,Dip PIPE STAND UNDER CHANGE ORDER NO. 2. APPROVED BY: T'MB TO BE REUSED METERING CHAMBER- EXISTING SECTION C CONDITIONS AND DEMOLITION RECORD PLAN '"=5' PLAN - ® SECTION A THIS RECORD PLAN WAS PREPARED BASED ON LIMITED INFORMATION SCALE: 1"=5' EQUIPMENT TO BE REMOVED AND DISPOSED OF 1"=5' GATHERED DURING CONSTRUCTION OF THE PROJECT AND INDICATES ONLY SIGNIFICANT CHANGES MADE FROM THE DESIGN PLANS DURING CONSTRUCTION. C+LJCC� �7r,CC a/t/oe Tigh!t1!!nnd LIMITS OF 100-FOOT BUFFER ZONE GENERAL NOTES: eers (AND PEABODY 100-FOOT NO DISTURB ZONE) �� 1. EXISTING BASEMAP INFORMATION BASED ON THE FOLLOWING: 53 Southampton Road ® � tts BACKFILL WITH STANDARD 00 A. 1975 PEABODY-SALEM INTERCEPTING SEWER, SHEETS C-3, S-1 AND S-2, PREPARED BY METCALF & EDDY, INC., DATED (413)Westfield, Massachusetts DMH ce GRAVEL BORROW 4 7 75. 100 / /00 www.tighebond.com HARMONYB. SOUTHERN SUBCHAMBER DETAILS, 36—INCH DUCTILE IRON REPLACEMENT PIPE, DRAWING NO. 6, ADDENDUM NO. 2, PREPARED BY GROVE_ '00 ATC ENVIRONMENTAL DATED 11/21/95. 75" RC INTERCEPTING SEWER 52 BR/CK INTERCEPT/NG SEWER ROAD ' DMH STRUCTURE M C. REMOTE FACILITIES UPGRADE, PEABODY GREASE AND GRIT FACILITY PLANS AND SECTIONS, PREPARED BY MALCOM PIRNIE AND 10 SEE SHEET 5 WESTON & SAMPSON ENGINEERING, INC. DATED 1/9/98. \ CB 76' RC /NTERCEPTI/yG WER SEOMH / ` B?PASS + �� \ D. GRIT AND GREASE CHAMBER AT SALEM-PEABODY LINE, SHEETS 1-20, PREPARED BY METCALF & EDDY, DATED DECEMBER 1945. _ - FOUNDATION FROM \ _ _ DECOMMISSIONED FACILITY / E. FIELD MEASUREMENTS. WALK 2• LOCATIONS OF EXISTING PIPES, STRUCTURES, UNDERGROUND UTILITIES AND OTHER SITE FEATURES SHOWN IN THESE CONSTRUCTION BITUM/NOUS WALK - _ BITUMINOUS INLET CHANNEL of ' -- „ - - _ �% DOCUMENTS ARE NOT WARRANTED TO BE EXACT, NOR IS IT WARRANTED THAT ALL UNDERGROUND STRUCTURES ARE SHOWN. DECOMMISSIONED GREASE LIMIT OF SILTATION FENCE SERu TER - --- - A%% CONTRACTOR IS RESPONSIBLE FOR VERIFYING AND CONFIRMING ALL DIMENSIONS AND LOCATIONS. AND GRIT CHAMBER 2'xs' ACCESS HATCH '` � SEE DETAIL THIS SHEET (TYP) / \ 3. SOIL BORING ADVANCED BY NEW HAMPSHIRE BORING OF DERRY, NEW HAMPSHIRE ON DECEMBER 27, 2006. SEE SPECIFICATIONS, STRUCTURE N SUMP PUMP ' B a PIPIN O O APPENDIX B FOR BORING LOG. �H OF M.. SEE SHEET f IMPROVEMENT MANHOLE 2 TODD M. y FOR DETAILS SEE SHEET Q\N 4. ALL AREAS DISTURBED BY THE CONTRACTOR, NOT OTHERWISE COVERED WITH PAVEMENT, STONE OR STRUCTURES UNDER THIS BROWN N s'xs' AccEss � CONTRACT SHALL RECEIVE 6" OF LOAM AND SEED, UNLESS OTHERWISE DIRECTED BY THE ENGINEER. o SANITARY HAT H ELECTRICAL AND STOP LOG YPASS RING TELEPHONE � 9 No 37&34 ti _ PING - OVERHEAD WIRES '00 G\�•� 5. CONTRACTOR SHALL COORDINATE METERING STATION BYPASS NTH THE OWNER AND ENGINEER. CONTRACTOR SHALL SUBMIT REDIRECTION EVICES CHAMBE DETAILED PLANS AND SPECIFICATIONS OF BYPASS OPERATIONS TO ENGINEER FOR REVIEW AND APPROVAL 30 DAYS PRIOR TO f SEE NOTE 5 EET 4 , E EDGE OF PAVEMENT `% SCHEDULED BYPASS INITIATION DATE. BYPASS SHALL BE CONSTRUCTED SUCH THAT NO WASTEWATER SHALL FLOW INTO THE LEGEND 36 Dl "' �� WORKSITE PIPING AND WORK AREAS. REFER TO SECTION 01510. 6•IS�� i♦ ,.• 00 do / 6. UPON COMPLETION OF BYPASS, CONTRACTOR SHALL PUMP REMAINING CONTENTS OF METERING STATION PIPING AND ASSOCIATED PZ/• / / STRUCTURE M BYPASS/ISOLATED AREA TO THE ACTIVE SANITARY SEWER SYSTEM IN STRUCTURE M. CONTRACTOR SHALL SUBMIT / ..1'' _ - � THE DEWATERING AND DISPOSAL METHOD TO THE ENGINEER FOR REVIEW AND APPROVAL. BUILD G 00� / _ � , _ LIMITS OF FEMA / / �� FLOODWAY 7• CONTRACTOR SHALL MAINTAIN WASTEWATER FLOW THROUGHOUT THE CONSTRUCTION PERIOD. CONTRACTOR SHALL NOT OPERATE ABOVE- ADE CONCRETE SLAB i Pi•' FROM BELO GROUND STRUCTURE / ./�• DISTRICT WASTEWATER FACILITIES. CONTRACTOR SHALL REQUEST REQUIRED DISTRICT ASSISTANCE WITH OPERATING DISTRICT FROM DECOMMISSIONED •/ , / N P`�' EQUIPMENT A MINIMUM OF 72 HOURS IN ADVANCE OF NEEDED ACTIVITY. BIIUMINOU PAVEMENT �0 0 ACCESS w-Wrrr / GP WPcsl Bt SOIL BORIN FACILITY (TYP) O �P4 • j R��fER PND WPtER 8. LIMIT OF WORK SHALL BE WITHIN THE FENCE LINE ON THE SOUTH ESSEX SEWERAGE DISTRICT OWNED PROPERTY AND WITHIN THE VA OF IV4,r �S'x� HA rCH ABOVE / . . . . . . �,(vQ / ORS WP�R g00tE PUBLIC WAY, HARMONY GROVE ROAD, ALONG WITH EASTERLY BOUNDARY OF THE PROPERTY. o�� DAVID J. any` UTILITY POLE O�Q TOP OF BANK ,. (�P D Ur10ER 9. ALL SURPLUS EXCAVATED MATERIAL ON THE PROJECT SITE SHALL BE REMOVED AND DISPOSED OF AT A PERMITTED OFF—SITE POPICe�czvrc . FACILITY IN ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS. EXCAVATED MATERIAL MAY CONTAIN URBAN DEBRIS, pR0 374B1a e HA2 WETLAND FL CE AREA ��/� ' FORMER DISCHARGE PLUGGED OUILEr o �o/SIE ,'� BOUNDARY FLAG OCAl10N �j� /••/' } SUCH AS COAL AND COAL ASH. SOIL TRANSPORTED OFF—SITE SHALL BE ACCOMPANIED BY ABILL—OF—LADING OR MATERIAL fss BACKFILL WITH NATIVE MATERIAL SHIPPING RECORD TO BE SUBMITTED TO THE ENGINEER. r — — — — — WETLAND RESOUR AREA G\ REMOVED FROM EXCAVATION 10. CONTRACTOR SHALL INSPECT EROSION AND SEDIMENTATION CONTROL BARRIERS AFTER EACH STORM EVENT AND REPAIR AS NEEDED BOUNDARY OR DIRECTED BY THE ENGINEER. -a--0---o— SILTATION FENCE LO TION � EXISTING CHAIN LINK FENCE - LOCATION APPROXIMATE 11. ELEVATIONS ARE BASED ON SOUTH ESSEX SEWERAGE DISTRICT DATUM WHICH IS MEAN LOW WATER AND IS 4.46 FEET BELOW USGS LIMITS OF FLOODWAY MEAN SEA LEVEL DATUM. __ --- FENCE LINE AND LIMIT OF WORK IMPROVEMENTS 12. IF A PORTION OF THE PERMANENT FENCE IS REMOVED DURING CONSTRUCTION, PROVIDE A TEMPORARY BARRICADE DURING THE SITE PLAN HOURS WHEN THE CONTRACTOR IS NOT ON SITE TO SECURE THE DISTRICT FACILITY AND PREVENT UNAUTHORIZED ACCESS. 1"=20' TEMPORARY BARRICADE WILL BE SUBJECT TO REVIEW AND APPROVAL OF ENGINEER. 13. APPLY ANTI-SEIZE COMPOUND SUCH AS NEVER-SEEZ OR APPROVED EQUAL TO ALL FASTENERS. 14. CONTRACTOR SHALL BE RESPONSIBLE FOR. PROVIDING SUITABLE SIGNAGE, TEMPORARY FENCING, TEMPORARY BARRICADES, TEMPORARY PLATES, AND ANY OTHER TEMPORARY FACILITIES TO PROTECT THE PUBLIC DURING THE WORK, INCLUDING ESPECIALLY Upgrade of THE WORK AT STRUCTURE M, A PORTION OF WHICH IS LOCATED BELOW HARMONY GROVE ROAD. 'I'A" CLASS I BITUMINOUS CONCRETE Peabody Metering TOP COURSE 11h" CLASS I BITUMINOUS CONCRETE Facilities BINDER COURSE APPLY SEED CONSERVATION COMMISSION NOI NOTES: SAW CUT (TYP) 6" LOAM 1. PEABODY ASSESSORS MAP 86, LOT 135A. EXISTING PAVEMENT 12 EXISTING VEGETATION South Essex 2. SALEM ASSESSORS MAP 16, LOT 240. \ \ 3. ESSEX COUNTY REGISTRY OF DEEDS, BOOK 3462, PAGE 541. Sewerage District w w = opo O \ � 4• PARCEL OWNED BY SOUTH ESSEX SEWERAGE DISTRICT. � Z N po8�o80 0 // // // // // / Contract No. 06-2 5. ACCORDING TO FEMA FIRMS 250999 0001B (PEABODY) AND 250102A (SALEM), THE PROJECT AREA IS U, Z �� `�' APPROXIMATE LIMIT OF SITUATED WITHIN THE LIMITS OF 1010-YEAR FLOODING (ie. BORDERING LAND SUBJECT TO FLOODING). o0 F W 8 DISTURBED AREA Salem Massachusetts om � . ' � . �. � : z 5 N MECHANICALLY COMPACT 12" "' PROCESSED GRAVEL BASE IN 6" �a °°•'` LIFTS FOR PAVEMENT REPAIR ¢ w 12" ' 12" MECHANICALLY COMPACT TRENCH MIN. MIN. BACKFILL MATERIAL IN 1 FOOT LIFTS. 3 3 SEE NOTE 1. _j Ate, WORK ZONE o APPROXIMATE LIMIT OF- DISTURBED PAVEMENT A� SILT FENCE ELAN fO Z z " " SILT FENCE �: • . . . ST KES SPACED WOOD POSTS AT 4'-5't O.C. SILT FENCE FINISHED SUITABLE BACKFILL EXCAVATION IN EXCAVATION IN GRADE -7 1 07/08 Record Plans SILT FENCE SUITABLE EARTH LEDGE Mark Date Description PROJECT NO: 5152612 NOTE; fO RUNOFF FILE: SHEET2 1. THE CONTRACTOR SHALL BE ALLOWED TO USE NATIVE MATERIAL REMOVED /�\ DRAWN BY: TMF �\ . /~�/ DURING EXCAVATION FOR THE PROPOSED WORK FOR BACKFILL IF THE «: ��\, \/ CHECKED: MPM, DJP MATERIAL COMPLIES WITH SECTION 02315 OF THE SPECIFICATIONS, UNLESS °00 GRADE ? APPROVED 3Y: TMB NOTED OTHERWISE. MATERIAL IDENTIFIED AS UNSUITABLE IN THE m. SPECIFICATIONS OR DURING CONSTRUCTION SHALL BE REPLACED WITHSEE DETAIL A 6" MIN. PROPOSED SITE PLAN STANDARD GRAVEL BORROW IN ACCORDANCE WITH SECTION 02320 OF THE FABRIC SPECIFICATIONS. BACKFILL PROCEDURE SHALL COMPLY WITH SECTION 02315. RECORD PLAN SECTION A-A DETAIL A TRENCH DETAIL SILT FENCE SCALE: AS SHOWN THIS RECORD PLAN WAS PREPARED BASED ON LIMITED INFORMATION NO SCALE NO SCALE GATHERED DURING CONSTRUCTION OF THE PROJECT AND INDICATES ONLY SIGNIFICANT CHANGES MADE FROM THE DESIGN PLANS DURING CONSTRUCTION. SHEET 2 SHEET 7/25/08 UPGRADE OF PEABODY METER-ING FACILITIES SOUTH ESSEX SEWERAGE DISTRICT SALEM , MASSACHUSETTS CONTRACT 06 =2 NO . JUIV2007SOUTH ESSEXSOUTH ESSEX SEWERAGE BOARD SEWERAGE DISTRICT STAFF WALTER A. DEFILIPPI , P . E . Xti \ �` T � k' . y•'1 HAROLD G . NEWHALL CHAIRMAN EXECUTIVE DIRECTOR 9NTERCH RICHARD M . CARNEVALE P . E . L. S . P . A. HT, JR. , P . E . DIRECTOR OF PUBLIC SERVICES PEABODY sy ARTHUR KNIGHT, . .^�f•a� R Ce y �..y !' -� . . GdI Cw•ae �` h'" '$.ftC ��%9 •��� DISTRICT ENGINEER. Pk KRICHARD RENNARD ALAN F TAUBER. TJR• , P . E DIRECTOR OF PUBLIC SERVICES SALEM tws, FRANK J . KILLILEA, JR. , P . E . COMMISSIONER OF PUBLIC WORKS, BEVERLYPROJECT LOCATION „f RICHARD P . RODGERS P . E . .�, j TOWN ENGINEER DANVERS , � `,; :• - _�„ DANA E . SNOWk SUPERINTENDENT OF WATER AND SEWER ` �r ' t •4 dc f, DEPARTMENT, MARBLEHEAD �� , scm .� ��� yPelm SHEET NO. <e� TITLEPak 1 COVER SHEET x, � << , . 4 ..� , he&Bond � ;�_ f��l � r . _,�';,,. �.'+ �fa•� '2 PROPOSED PLAN , ,� GOtlDpuRc � �*� •t. .� - Consulting Engineers 3 METERING CHAMBER - EXISTING CONDITIONS SCALE: 1 :25000 AND DEMOLITION PLAN t� �F M �P� D 4 P`AN OF Mqs. �� TODM. �y � '&`�` BROWN "n �� DAVID J G o SANITARY PDPIEIARCZVK m 4 METERING CHAMBER - PROPOSED IMPROVEMENTS 9 9 37 No 37481 �f�SSC,STERN 90,>�.SECiSTEA4G\���� 5 STRUCTURAL NOTES AND STRUCTURES M AND N S�ONA E REFERENCE DETAILS 6 STRUCTURE "M" STRUCTURAL IMPROVEMENTS- RECORD PLAN PLAN, SECTIONS, DETAIL, AND NOTES (ADDED BY THIS RECORD PLAN WAS PREPARED BASED LIMITED INFORMATION COMPLETE SET 6 SHEETS GATHERED DURING CONSTRUCTION OF THE PROJECT AND INDICATES ONLYCHANGE ORDER NO. 1 ) SIGNIFICANT CHANGES MADE FROM THE DESIGN PLANS DURING CONSTRUCTION. 7/28/08 51526\COVER Tighe&Bond Consulting Engineers LIMITS OF 100—FOOT BUFFER ZONE N, 53 Southampton Road (AND PEABODY 100—FOOT NO DISTURB ZONE) Westfield, Massachusetts s ® � 100 00 562-1600 www.tighebond.com 78" RC INTERCEPTING SEWER HARMONY GROVE ROAD00 00 to ® LEGEND — - 78" RC INTERCEPTING SEWER (BYPASS) � ' BITUMINOUS WALK 100 ® UCTURBUILDING 0 FOUNO A srRr-OUNDE M /,- `\ BITUMINOUS PAVEMENT --'-- — ---___ A7/ON FROM DECOMMISSIONED FACILITY �'� ABOVE—GRADE CONCRETE SLAB 0 _ x -- - - Bt SOIL BORING APPROXIMATE LIMIT OF WORK e _� — = T' v ----- _ _ UTILITY POLE ' INLET CHANNEL OF LIMIT OF SILTATION FENCE DECOMMISSIONED GREASE SUMP PUMP B7 IA2 WETLAND RESOURCE AREA \ - O � O AND GRIT CHAMBER �y-PROPOSED PIPINGBITUMINOUS / �` � BOUNDARY FLAG LOCATION IMPROVEMENTS WALK i STRUCTURE N EDGE OrPAVEMENT, 0 \y BOUNDARY RESOURCE AREA RING CHAMB 00 E s I ���� "' F• 0 ° ° SILTATION FENCE LOCATION MANHOLE PLwc PORT (LOCA TION APPROXIMATE LIMIT OF WORK BASEMET N :y APPROXIMATESAMPLE PUMP �' _ BELOW a � �"'� � . . . . . . LIMITS OF FLOODWAY AND GRINDER �„ •' VENTILATION �•.�' _ — _ - _ ..� FAN AB O\ OACCESS PORT BELOW GROUND 10 STRUCTURE FROM �i x0 W/HH®TTCH ABO VE ,� �•,i'•� � �/��� G PN P W YS) DECOMMISSIONED FACILITY u O - A / 1 \N P O� O� TOP OF BANK IN R� Es PND / (� iQ� P5 NOR�ER WPZER g0D (n\ LIMITS OF FEMA FLOODWAY-1/ O� 6 0���/ \ O / �-P'' i FORMER DISCHARGE PLUGGED OUTLET I G\ NOTES: 1. PEABODY ASSESSORS MAP 86, LOT 135A. 2• SALEM ASSESSORS MAP 16, LOT 240. 3. ESSEX COUNTY REGISTRY OF DEEDS, BOOK 3462, PAGE 541. 4, PARCEL OWNED BY SOUTH ESSEX SEWERAGE DISTRICT. 5. ACCORDING TO FEMA FIRMS 250999 0001B (PEABODY) AND 250102A (SALEM), THE PROJECT AREA IS Peabody Metering SITUATED WITHIN THE LIMITS OF 100—YEAR FLOODING (ieB . BORDERING LAND SUBJECT TO FLOODING). of �) Ii WORK ZONE li � Chamber PROPOSED IMPROVEMENTS Improvements SITE PLAN 1"=20' B South Essex SILT FENCE SEE DETAIL A Sewerage District PLAN 2"x2" WOOD STAKES SPACED AT 4'-5'f O.C. Salem, Massachusetts EXISTING GROUND WORK ZONE SILT FENCE /\\/\\/ SECTION B-;,@ toRUNOFF METERING CHAMBER 5'x5' HATCH 2x5' HATCH MANHOLE 5'x4' HATCH MANHOLE GRANITE EL 15.5 CURB SILT FENCE DECOMMISSIONED GREASE i u SILT FENCE SUITABLE BACKFILL � GRADE AND GRIT FACILITY i WOOD POSTS EL s.so 7 E78" INTERCEPTOR SEE DETAIL B 36'" DI � EL 7.33 j STRUCTURE M FINISHED DETAIL A METERING CHAMBER GRADE g EL 1.50 , EL 2.52 EL 0.75 /�\�\\� i I i EL -3.17 i I Mark I Date IDescription 36" C/ i --" -'--- \\�\\� PROJECT NO. 51526 t --- Z U FILE. Figure1_Dsize L------------------------------------ ------ ----- -- --- --j PROPOSED 36" SLIDE GATE m DRAWN BY: TMF REINSTALLED MAGNETIC PROPOSED a FLOW METER 6" MIN. CHECKED: MPC, DJP 11-1/4' BEND REPAIR EXISTING 36 DI OPENING RELOCATED 4" DRAIN (TYP OF TWO) WITH NON—SHRINK GROUT FABRIC APPROVED BY: TMB DETAIL B PROPOSED SITE PLAN - PROPOSED SECTION A—A LINK SEAL (TYP) SILTATION FENCE IMPROVEMENTS 1"=10' NO SCALE SCALE: AS SHOWN SHEET X 512010;