Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
376 HIGHLAND AVENUE - BUILDING INSPECTION
E HIGH*ANI) a F; January 2, 2007 Thomas St. Pierre, Salem Building Inspector Salem Building Department 120 Washington Street Salem, Massachusetts 01970 Re: Proposed Commercial Building Project 376 Highland Avenue, Salem, MA The following is intended to clarify the gross square footage, construction type and sprinkler requirements of the proposed commercial building project and at 376 Highland Avenue, Salem, MA. Building Use (Proposed) Business (B) 7,335 Square Feet (1"Floor) (7,335 / 100= 74 occupants) Mechanical Space (2"a Floor)(0 occupants) General Building Limits Construction Type 5B(Combustible Un-Protected Frame) Allowable Height&Area (T503) 2 Story (30'-0") 7,200 sf Actual Height &Area 2 Story (30'-0") 7,335 sf* Area Modifications * Street Frontage Increase (506.2) Where the building perimeter fronting on a street or other un-occupied space exceeds 25%, the area limits in(T503) shall be increased by 2% for each 1% of such excess frontage. Total Building Perimeter 363'-0" (100%) 25% of Building Perimeter 90'-9" (25%) Building Perimeter with un-occupied space as defined in(506.2) 242'-3" (66.7%) (1) continued..... RFK. K. Mornnt � Co. , Inc. P.O. Box 4485 ❑ Salem, Massachusetts 01970 978.744.5354 Fax 978.7408.740 .9161 Email: stafF@hhmorantncom 376 Highland Avenue Project January 2, 2007 Page 2 66.7% - 25% =41.7% Open Perimeter 41.7% Open Perimeter x 2 = 83.4%Allowable Increase The actual increase from 7,200 sf to 7,335 sf is approximately 2% which falls well below the allowable increase at 83.4%. This increase also falls below the 7,500 sf threshold(chapter 148, section 26G MGL) requiring sprinklers. The proposed 7,335 sf building is allowed by 780 CMR—Sixth Edition without an automatic sprinkler system based on section 506.2. If you have any questions regarding these or other issues for the proposed commercial building project at 376 Highland Avenue,please call my office. Respectfully submitted, Stephen W. Livermore Project Architect SWL/squarefootageltr1 On cl%wAd/,P fwp/yy L F.; Certificate No: 593-08 Building Permit No.: 593-08 Commonwealth of Massachusetts City of Salem Building Electrical Mechanical Permits This is to Certify that the BUSINESS located at ----------------------------------------------------- Dwelling Type 0370 HIGHLAND AVENUE 376 in the CITY OF SALEM ------ ------------------------ ----- ------------------------- Address Town/City Name IS HEREBY GRANTED A PERMANENT CERTIFICATE OF OCCUPANCY ST. JEANS CREDIT UNION This permit is granted in conformity with the Statutes and ordinances relating thereto,and expires ......... unless sooner suspended or revoked. Expiration Date --------------------------- Issued On: Thu May 22,2008 ---- --------- -------------------------------------------------------------- GeoTMS®2008 Des Lauriers Municipal Solutions,Inc. ---------------------------------------------------------------------------- a �� plviTlS�� *CN t►,�s r. 0370 HIGHLX ND AVENUE 376 --^ � 593-08 GIS#: i COMMONWEALTH OF MASSACHUSETTS Map: 03 9�— Block: CTTY ON JPILr:l'VY _f Lot: 0063 Category: New Building Pro # 593-08 UILDING PERMIT Projecect# JS-2008-000887 Est.Cost: $698,000.00 \ ` Fee Charged: $7,691.00 Balance Due: $:00 PERMISSION IS HEREBY GRANTED TO: Const Class: Contractor., License: Expires Use Group: NEW ENGLAND DESIGN ASSOCIATE Lot Size(sq.ft.): 36984 Owner: PULED REALTY TRUST Zoning: B2 Units Gained: Applicant: NEW ENGLAND DESIGN ASSOCIAAS Units Lost AT. 0370 HIGHLAND AVENUE 376 Dig Safe#: ISSUED ON. 20-Nov-2007 AMENDED ON. EXPIRES ON. 20-May-2008 TO PERFORM THE FOLLOWING WORK: NEW ST.JEANS CREDIT UNION jhb POST THIS CARD SO IT IS VISIBLE FROM THE STREET Electric Gas Plumbing Building Underground: Underground: Underground: Excavation: Service: / Meter: ,�,L� / �A Footings: Rough:`/`� Rough.-Cl o° Rough:�(�''—I ,I Foundation: Fins: �tr3 ,27 Final: Final 0/4'c' ��j®� Rough Frame: Tw,(, ( L7 ^� —ob' D.P.W. Fire Health Fireplace/Chimney: �1' Qz'— Insulation: Tw-ir�'�04- Meter: Oil w�v11 > �tl Final:' 91.'�Gi� House W .. � Smoke. r/ /�t/Ui A Treasury: Water: Alarm: Sewer: Sprinklers: -, THIS PERMIT MAY BE REVOKED BY THE CITY OF SALE PON VIOLATION OF AN,XOF ITS RULES AND REGULATIONS. I Sig daiuret Fee Type: Receipt No: Date Paid: Check No: Amount: BUILDING REC-2008-001100 20-Nov-07 28987 $7,691.00 e nCmy IMQQRTANT: r r G ' i !< i i j An �. upon ccmp et t-i, cib.Cr; , 1Gase call ext. 38'5 GcoTMS®2007 Des Lauriers Municipal Solutions,Inc. _ Y. 4 [7 A � e 4y4ti 111u 41 w n � � q YSCYE •G CITY OF SALEM BUILDING PERMIT + 1-44-r 3 Zo 6 2— CITY CITY OF SALEM ROUTING SLIP NEW CONSTRUCTION_¢ CERTIFICATE OF OCCUPANCY LOCATION: :E3?O Ava"DATES 1 09 APPLICANT• G��m G'�rysn�JGrzc�� O� / �q A RU4LI I��OYa 1 1}. lic klo, DATE: (93 WashingtonStreet) . CITY CLERK CHERYL LAPOINTE DATE: (93 Washington Street) r1 PUBLICS SERVICES /ZZ/�4,eve BRUCE THgton S _ DATE: �`—(l20 Washington Strut 4FlWATER !e DOTTIE THIBODEAU DATE: 102 U (120 Washington Street)4th !1 CROSS CONNECT SUP v BRIAN THIBODEAU (5 Jefferson Avenue) PLANMNG F'- "K. T.xrw 'n2 /Z U� (/�—J DATE: (120 Washington Street)3's Floor CONSERVATION COMMISSION FRANK TAORM DATE: (120 Washington Street)3n/Floor ELECTRICAL DATE: JOHN GIARDI (48 Lafayette Street) FIRE PREVENTION ERIN GRIFFIN DATE: (29 Fort Avenue) HEALTH ry , JOANNE SCOTTDATE: (120 Washington Street)4ib Floor BUILDING THOMAS ST.PIERRE DATE: (120 Washington Street) 3a Floor 05/22/2008 13:14 19782191170 STJEANS PAGE 01/01 MAY-21-2008 46:19 NEW ENIiLAND IPS'MIN 3-1 (a HlC�klLra�trJ (�,Aj , �. BAY STATE ll E S I G L4 ARMTEC'I URAL--FINAL AFFIDAVIT To the Building Commissioner of the City of Salem: " 1. certify, pursuant to 7€0 CMR of the Nbssaebusetts State Building Code, that I, or my authorized representative, have observed the work associated with the Architectural portions of ,the interior renovations for S6 Jean's Credit Union at 376 Highland Avenue. To the I-Mst,,of my knowledge, information and belief, the work has been done in conformance with the approved pians, and with the provisions of the Massachusetts state Building Code and the City of Salcm codes and ordinances. Brian P. O'Donnell _ #4161 Architect—Registration No. Architect",,;Signature BAY State Design,Ino. Company Data 70 Tower Office Park = Woburn,MA 01801 Address SEAIz xl' 52 � 781 932-2467 r� M Al Phone "�\�SS?iS A amu• THEN PERSONALLY APPEARED THE ABOVE NAMED AND MAIL OATH THAT THE ABOVE STATEMENTS BY THEM ARE TRIM. BEFORE ME, 4NOTARY LIC DATE 1:Mt,IFNTS',(fcK7F.NERAL1hIISCrtrch•ALGdm4o-Si.7mn',c M',I_08,dat r TOTAL P.00i May 19, 2008 Mr. Thomas St. Pierre Building Commissioner City of Salem 120 Washington Street Salem, Massachusetts 01970 Re: Proposed Commercial Facility(Shell), 376 Highland Avenue Dear Mr. St. Pierre, Based on multiple site visits through 05/16/08, proposed commercial facility(shell only), 376 Highland Avenue, Salem, MA has been reviewed, and to the best of my knowledge and ability, the project has proceeded in accordance with the drawings prepared by HHM (dated 04/3/07 w/revisions dated through 07/30/07 & on-site siding/trim material changes). Further, to the best of my knowledge and ability and based on documentation provided by the Contractors, the building(Shell) is substantially complete and ready to occupy. If you have any questions regarding this project, please call my office. Sincerely yours, ED 4R LIVE 9� 0 m No. 5294 n S n . Livermore SALEM, 00 MASS. , P ide (hhm) of% ►5�a'` SWL/shell-SCltr#2 ■■ II. II. Moran. & Co., Inc. PO Box 4485/221 Washington &reet (Delivery) Salem, MawaehaseLts 01970 Phone (978) 744-5354 Pax (978) 740-9161 BAY STATE D E S I G N ARCHITECTURAL - FINAL AFFIDAVIT To the Building Commissioner of the City of Salem: I certify, pursuant to 780 CMR of the Massachusetts State Building Code, that I, or my authorized representative, have observed the work associated with the Architectural portions of the interior renovations for St. Jean's Credit Union at 376 Highland Avenue. To the best of my knowledge, information and belief, the work has been done in conformance with the approved plans, and with the provisions of the Massachusetts State Building Code and the City of Salem codes and ordinances. Brian P. O'Donnell - #4161 Architect—Registration No. Architect's Signature Bay State Design, Ind— ��12-/0 Company Date 70 Tower Office Park `'''' Woburn, MA 01801 BR,q1 Address SEALS '. (781) 932-2467 Phone THEN PERSONALLY APPEARED THE ABOVE NAMED AND MADE OATH THAT THE ABOVE STATEMENTS BY THEM ARE TRUE. BEFORE ME, NOTARY U LIC DATE 1:\CLIENTS\@GENERAL\MISC\Arch-Affidavit-St.Jean's 05.I2.08.doe d 14 pawe SA� 04.A A44&4U#. Mat R~- 1301 M.c i.,acl,s" 02105-1618 Pl" (617) 727-3200 F" (617) 727-5?32 FINAL CONSTRUCTION CONTROL DOCUMENT (for Professional Engineers/Architects responsible for only a portion of a controlled project) Project Title: St. Jean's Credit Union Date: May 21,2008 Project Location: 376 Highland Avenue, Salem,Massachusetts Scope of Project: Renovations In accordance with Section 127.0 of the Massachusetts State Building Code sixth edition I,Evert O.Lindgren,Jr. Mass. Registration Number 22425 being a registered professional Engineer hereby CERTIFY that I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: [ ] Entire Project [ ] Architectural ( ] Structural [ ] Mechanical [ ] Fire Protection [X] Electrical [ ] Other(specify) for the above named project and that to the best of my knowledge, such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code, all acceptable engineering practices and all applicable laws for the proposed project. I further certify that I have performed the necessary professional services and I or my Representative have been present on the construction site on a regular and periodic basis to determine that the work has proceeded in accordance with the documents approved for the building permit and shall be responsible for the following as specified in Secion 116.2.2. 1. Review for conformance to the design concept, shop drawings, samples and other submittals which are submitted by the Contractor in accordance with the requirements of the construction documents. 2. Review and approval of the quality control procedures for all code-required controlled materials. 3. Be present at intervals appropriate to the state of construction to become generally familiar with the progress and quality of the work and to determine in general if the work is being performed in a manner consistent with the construction documents. Pursuant to Secion 116.4,I have submitted progress.reports together with pertinent comments to the Building Inspector. Upon completion of the work, I am submitting this Final Report as to the satisfactory completion of the work and readiness of the project for occupancy. Fb a�� ass9cy Signature and Seal of registered professional: = EVERT S 0. LINDGREN, J P.E L r .2 S SC ED AND O T BEFORE METHIS DAY OF 2008. sT ENGv� mr l /COMMISSION EXPIRES Mag,201 ` r- N0T Y PUBLIC 0 =1141a* 1301 $"zt., M",4, lw 0210 -161 S ?41" (617) 727-3200 F" (617) 727-5732 FINAL CONSTRUCTION CONTROL DOCUMENT (for Professional Engineers/Architects responsible for only a portion of a controlled project) Project Title: St. Jean's Credit Union Date: May 21,2008 Project Location: 376 Highland Avenue, Salem,Massachusetts Scope of Project: Renovations In accordance with Section 127.0 of the Massachusetts State Building Code sixth edition I, Charles P. Sharples Mass. Registration Number 28940 being a registered professional Engineer hereby CERTIFY that I have prepared or directly supervised the preparation of all design plans, computations and specifications concerning: [ ] Entire Project [ ] Architectural [ ] Structural [X] Mechanical [ ] Fire Protection [ ] Electrical [ ] Other(specify) for the above named project and that to the best of my knowledge, such plans, computations and specifications meet the applicable provisions of the Massachusetts State Building Code,all acceptable engineering practices and all applicable laws for the proposed project. I further certify that I have performed the necessary professional services and I or my Representative have been present on the construction site on a regular and periodic basis to determine that the work has proceeded in accordance with the documents approved for the building permit and shall be responsible for the following as specified in Secion 116.2.2. 1. Review for conformance to the design concept, shop drawings, samples and other submittals which are submitted by the Contractor in accordance with the requirements of the construction documents. 2. Review and approval of the quality control procedures for all code-required controlled materials. 3. Be present at intervals appropriate to the state of construction to become generally familiar with the progress and quality of the work and to determine in general if the work is being performed in a manner consistent with the construction documents. Pursuant to Secion 116.4,I have submitted progress reports together with pertinent comments to the Building Inspector. Upon completion of the work,I am submitting this Final Report as to the satisfactory completion work and readiness of the project for occupancy. pP M ?� p CHARLES Z Signature and Seal of registered professional: P. s SHARPLES 28940 SC ED of TO BEFORE ME THIS DAY OF 2008. COMMISSION EXPIRES May 19, 201 NAR PUBLIC er in, rt�'_� Arthur W Rose, P.E.PLLC Structural Engineer 33 South Commercial Street Manchester, NH 03101 (603) 622-6066 (603) 624-2244 Fax March 27, 2008 Mr. Tim McCain - Morton Buildings, Inc . 885 Londonderry Turnpike Auburn.: NH 0_1032-7.616 Re: Morton Building for Puleo Realty Trust 376 Highland Ave. Salem, MA Morton Job # 118-2366 Dear'. Mr.:r;McCa n:; This :letter-.-report will ;confi,rm our.-conversation subsequent to our-,recent ,meet,i-ng .at -the, above. referenced,building,_site. The purpose of my meeting with you was to review the construction of the .mezzanine structure-within the building as designed by Morton Buildings,,.:Inc..,- The building :is ,to be occupied by .St . , Jean' s . Credit Union.: .ba cd -6.. :y* ob^er'"aifi o ,and -peri cnra 4_t-- i +-1 ,q mtr nr'ni n,n fih�.t the construction .of the mezzanine framing, having a design live load.of 80 psf has been constructed in accordance with the approved Morton Building framing plans and.-the Commonweaith. of Massachusetts StateBuildingCode. Please do_ not- hes:itate to contact me- should-you have any .questions :or,;comments- regarding this matter e y prulyu;y_ours, ��ZHOFPggss3^ P S SE V ROSE *rthur;%� ose, P . �YG E `'�', .STP' c, URAL y AWR/zp Na30734 �,10,\:.1S T Efit, aid Arthur W Rose, P.E.PLLC Structural Engineer 33 South Commercial Street Manchester, NH 03101 (603) 622-6066 (603) 624-2244 Fax November 9, 2007 Mr. Tim McCain Morton Buildings, Inc. 885 Londonderry Turnpike p„burn, DTu 03032-161 r Re: Morton Building for Puleo Realty Trust 376 Highland Ave. Salem, MA Morton Job # 118-2366 Dear Mr. ;McCain,-' This letter, report will ,confirm out conversation this date subsequent to our meeting at the above referenced building site. The purpose of my meeting with you was to review the on going construction of the 60 ft x 12 ft x 120 ft wood framed building structure as designed by Morton Buildings, Inc. Based upon my observationsand experience it is my opinion that th,-: a:ood framing For the building, which- is to h uccupied by the St. Jean' s Credit Union, is . approximately 95 complete to date. The framing as observed is in accordance with the approved Morton Building framing plans and the Commonwealth of Massachusetts State Building Code. Please do not hesitate , to contact me should you have any questions .or. comments +regarding this matter. Very. truly...yours, _ IN OF AU ARTHUR W. rthur W. se, P.E. ROSE AWR/zp STRUCTURAL y No.30734 °9�F9FOISTEP����``� FSS/OHAI ENS' Arthur W Rose, P.E.PLLC Structural Engineer 33 South Commercial Street Manchester, NH 03101 (603) 622-6066 (603) 624-2244 Fax October 25, 2007 Mr. Tim McCain Morton Buildings, Inc . 885 Londonderry Turnpike Auburn, NH 03032-1616 Re: Morton Building for Puleo Realty Trust 376 Highland Ave. Salem, MA Morton Job # 118-2366 Dear Mr. McCain: This' let'te'r 'repor`t will confirm our conversation this. date subsequent to our meeting at the above referenced building site. The purpose of my meeting with you .was ' to -review the on going construction of the 60 ft x 12 ft x 120- ft wood framed building structure as designed by Morton Buildings, Inc. Based upon my observations and experience ,it is my opinion that the wood framing for the building, which is to be occupied by. the St. jeai,' s Creel il.on has Dein to date. appr� .atr:l-,: 70 percent.. ` The framing as observedisin accordance with the approved Morton. Building framing plans and the Commonwealth of Massachusetts State Building Code. Please do not hesitate to contact me should you have any:. questions-or comments regarding this matter. .Vezy hr. Y60 �ZN OF M4SS9� Arth W. ose, P.E. �� ARTHUR W- ROSE AWR/zp n STRUCTURAL y v No.30734 9FGISTEA������Q FSS/ONAI ENG JAMES HOWLAND BALLOU, A.I.A. ARCHITECT pu ru.iNo ' . Dary- j'ib i`iynl�ind Avenue Salem old, Ol970Jitno 1.6, 1989 < N C Lo re: 'lita1 F_iei.(; Reoort o� "' rn � fM y� f•, 17)E+t4_r Chuck., "3 n rm w o Enc-i osed herewl Li: Jr � ( O- Y' 6: .n.l .i-..tc r.ec Lorl, ftl F the (; ,,... _r tqv May 30 Fie.,! Report of your pro ect. I .ail 4 tnth �. � : 'cu and '.:lc: Salem Bu.JA' dincj D.�, iar'tment a. c.-)V)i on =•1ay .:0th. As far as :C am concerned, a11. work prepared. by my o]`r; ice. !.ne 3::chi'.ec ure ::nn_ :', ur_tural engineering, has been compiCted as a.i.1 pJ.ans an(! Uur- ineS 8t>ecified.. The buildinq _.s ready for u-se anct occupancy. t, m enciosj.n two copJicc9 of this Lette_r fOI' whatlever corker-'ns n8cess2ry; mile of Sa�.�`IP., Ct1e arming DepT.;. , or the State if so re qui,ed.. It nas been a real- ::1.e.asure workiag w,; ;-'h you.. i relish You the >e- t of uck w,.t ;--he new ice cream parlor. Si Q4�'�S g H:BgCy�Fp " No.13911 ? SALEM t ; AS y OF MPSSP��, 14 Cambridge Street P.O. Box 807 Salem, Ma. 01970 (617) 745-1354 June 9, 1989 n c� � = w City of Salem A m Building Department cnC or One Salem Green ',-M o a Salem, Massachusetts 01970 m e Re : Encroachment Problem n Puleo' s Dairy Cn. cco Highland Avenue Dear Sir or Madam: We are aware of the encroachment of the existing ice cream stand onto the property occupied by the new dairy building. As previously communicated to you, our intention was to have the building removed by the prospective new tenant which would lease the premises containing the ice cream stand. The arrangement with Scott Foods has fallen through; therefore, the undersigned agrees with the Building Department that the stand will be removed so that the encroachment will be corrected. This work will be accomplished before sixty (60) days from this date. PULEO REALTY TRUST BY:CL. Charles Puleo lda PU LEO'S DAIRY TEL. DAIRY: 744.4860 376 HIGHLAND AVENUE TEL. RES: 744-4957 SALEM. MASSACHUSETTS Charles M. Puleo Owner / Manager 4 Puleo' s Dairy a Salem, Ma. est a—kn U47: Q _ Sept. 30, 1988 el"tity Of Salem Muilding Inspector aw -ig)ne Sal.em Green Cs .Pal4m, Ma. This letter is to inform you and assure you of my intention to remove the existing ice cream stand, Puleo ' s Dairy Bar, which is encroaching on the lot, line. Removal will begin as soon as the renovations have progressed at the dairy next door. If there are any questions pertaining to the work involved, please call or bring it to my attention during inspections. Sincerely, arles M. Puleo \v P �T,PEE T J 2B � . A �4B9 P 1 A 24G H �7 n LOTS P4S N 3� 27,9 i � - EXisridG 27--� ' 0 - - -�=s�f�`- -- - - �//Gf/Gf',�/O fes'✓E.,l��/E /7G G Fit/TE'F�G ST �f�UGU il�l/9 SS. 0 4�0 nc i `1 i i. i Kn I � I v 0 v ov h 0h � Jj tNi \j t i Y 1 V .� ..y...._.v.,..�.......... V 19 � O U V I� m fo V i e ,k l F Cite of Oatem, Alaaacbm5etto Public Propertp Mepartment g �3uilbing ?rgepartment One balem Oreen 745-9595 Cxt. 380 William H. Munroe Director of Public Property Inspector of Buildings Zoning Enforcement Officer October 4, 1988 Charles M. Puleo 376 Highland Avenue Salem,MA. 01970 RE: 376 Highland Avenue Dear Mr. Puleo, Your application for renovations at 376 Highland Avenue have been approved. Please be advised that the following must be addressed. I . Emergency lighting 2. Rear exist handicapped accessable. 3. Parking plan drawn to scale. 4. Railings for handicap ramp. 5. Panic hardware for egress doors. Progress reports shall be submitted on a bi-weekly basis from your Architect . Sincerely, :, (,/ 2 'r�' /( David J. Harris Assistant Building Inspector C.C. James Ballou Dennis Monico City Solicitor Ward Councillor JAMES H. BALLOU, A.LA. / LETTER ARCHITECT ' I�/ IN REFERENCE TO: P. 0. BOX 807 SALEM, MA 01970 FIRST CLASS MAIL INTER-OFFICE /�f �1(.'J� �/ HOW TO USE THIS FOR UP/� LETTER TO SAVE TIME. �� G� /3UL�iN�� �' Type or write your reply in the space below. Then mail the white copy to us and keep the pink copy for your files. '- f/ --''-( •�-I�/ '---- - -- -" '"--- You'll save time and effort, and we'll have your answer S/�✓_f'�`� Q��' ����® much faster! Thank you. rol.o DATE .f �`.�C1C _-__ DATE. _.__ .. - MUD •. dS._...-. SIGNED SIGNED DAYTIMERS RE ORDER Na. 2352—Prrretl n USA CONSTRUCTION C2N5ldO .1N4 `qT PROJECT NUMBER: PROJECT TITLE: ,ADO)TI %f b WtU j 004W 4o RM °88 PROJECT LOCATION: H(40L poo RECE" �m NAME OF BUILDING: NATURE OF PROJECT: I(r- am4m PAJeLUY2 Fh_) 'rj0q -rd 601-rIN4 r$UI�DII��j IN ACCORDANCE WITH SECTION 127.0 OF THE MASSACHUSETTS STATE BUILDING CODE, I, PrM� +I - (NLfWC V Registration No. I5 BEING A REGISTERED PROFESSIONAL ENGINEER ARCHITECT HEREBY CERTIFY THAT I HAVE PREPARED OR DIRECTLY SUPERVISED THE PREPARATION OF ALL DESIGN PLANS, COMPUTATIONS AND SPECIFICA- TIONS CONCERNING: ENTIRE PROJECT ARCHITECTURAL ✓ STRUCTURAL FIRE PROTECTION ELECTRICAL MECHANICAL OTHER (specify) 12�(-r(!(LAL rZ02t2-1 1-4. Q%)MPF P,JF - $*01(4. Nbl FOR THE ABOVE NAMED PROJECT AND THAT, TO THE BEST OF MY KNOWLEDGE, SUCH PLANS, COMPUTATIONS AND SPECIFICATIONS MEET THE APPLICABLE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE, ALL ACCEPTABLE ENGINEERING PRACTICES AND APPLICABLE LAWS AND ORDINANCES FOR THE PROPOSED USE AND OCCUPANCY. I FURTHER CERTIFY THAT I SHALL PERFORM THE NECESSARY PROFESSIONAL SERVICES AND BE PRESENT ON THE CONSTRUCTION SITE ON A REGULAR AND PERIODIC BASIS TO DETERMINE THAT THE WORK IS PROCEDING IN ACCORDANCE WITH THE DOCUMENTS APPROVED FOR THE BUILDING PERMIT AND SHALL BE RESPONSIBLE FOR THE FOLLOWING AS SPECIFIED IN SECTION 127.2.2: 1 . Review of shop drawings, samples and other submittals of the contractor as required by the construction contract docure is as submitted for building permit, and approval for conformance to the design concept. 2. Review and approval of the quality control procedures for all code-required controlled materials. 3. Special architectural or engineering professional inspection of critical construction components requiring controlled materials or construction specified in the accepted engineering practice standards listed in Appendix B. PURSUANT TO SECTION 127.2.3, I SHALL SUBMIT PERIODICALLY, A PROGRESS REPORT TOGETHER. WITH PERTINENT COMMENTS TO THE STATE BUILDING INSPECTOR. UPON COMPLETION OF THE WORK, I SHALL SUBMIT A FINAL REPOR AS TO THE SATISFACTORY COMPLETION AND READINESS OF THE PROJECT FOR OCCUPANCY. SIGNATURE SUBSC& BED AND SWO N TO BEFORE ME THIS OF 7rJr5 1998 8 TSCS9 R P[IR LTC MV rnMMTgQTrMi RVPTPVq WEARCHITECT'SITECT'S ARCHITECT a RALLOU aull&INC:� �. `• ; i1 O7� CONSULTANT ❑ SG rAr veiD .r- ST FIELD REPORT coNsu • P. 0. OBD;: G�e77 AIA DOCUMENT 6711' �^ FIELD ❑K,t��, qq SALEM• MA 011D70 GL[lS )�` / w�l IdT Ff UIORT NO �7G N14H[9tio r{u RECEIN�,�� CONTRACT: r SJ�1 Nam CITY _4F 5AL�Rp�;�.1T'S PROJECT NO: S j DATE TIME 22 ' 36p� WEATHER CLOY OY TEMP. RANGE 6z o' cJ /�✓ EST.°J. OF COMPLETION 10 . CONFORMANCE WITH SCHEDULE WORK IN PROGRESS PRESENT AT SITE `7257 ��/sy�c>t„u' Siv�,>� �xc,��✓s9-yic�✓ - OBSERVATIONS oN SoL/a L E%�, vr2.�cia.� 73 7::5'LL cc�ar 'jZ �FvEL jor, �✓7/N�j -Q �ryys I • /��i�2iNS ��iq�i7y ,s /�iJ•�ci�'h'TE • � ITEMS TO VERIFY INFORMATION OR ACTION REQUIRED A c:.,:9 O.EiCMiTr=CT • ATTACHMENTS 'ice -AMr ST. ALCM, itiA 9°97Q REPORT B AIA DOCU T 6711 • ARCHITECT'S FIELD REPORT • OCTOBER 1972 EDITION • AIA© • m 1972 THE AMERICAN INSTITUTE OF ARCHITECTS,1735 NEW YORK AVE., NW, WASHINGTON,D.C.20006 page of pages � I RALLOU ARCHITECT'S OWNE ARCITECT o B. JL$71N3 °T FIELD REPORT CONSULTANT s� cns��"aE� ,r ;}T• i''. e+. CSD:: d�e97 AIA UOCUMCM 6771' f- FIELD ❑ SALEM. MA 01:'9'0 PROJECT: �LLvJ 39', FUpLp � 1�,�1f'� a.�al tlaiV FI'EL7D REPORT N0 CONTRACT: 5tlt,A14 LNw� � CITY OF SALRECEl'EFFipJygflCI IITECT'S PROJECT NO: S �'� DATE lC - 17-90 TII,ME3�j� WEATHER CLoy t/, -1 TEMP.RANGE EST.°Io OF COMPLETION d. %U CONFORMANCE WITH SCHEDULE 1+ WORK IN PROGRESS PRESENT AT SITE �110/j4:-. �L!�25�7 //�./sPf'7ll,c.l S/.4��,� �c'�/��✓s�"y/J�✓ Gi �JCld �c �AICI t/�c2 1//siTa /J S»� L/�JT ��✓��� OBSERVATIONS yS /Al 7 /7 I ITEMS TO VERIFY INFORMATION OR ACTION REQUIRED r. 9 L:.� • AF2C1-0I'i'r=CT . ATTACHMENTS 't�` '7AML.�e;l�C''+` ST. ALLM, NSA 2w7Q REPORT B AIA ROCU T 0711 • ARCHITECT'S FIELD REPORT OCTOBER 1972 EDITION • AIA© • m 1972 THE AMERICAN INSTITUTE OF ARCHITECTS,1735 NEW YORK AVE., NW, WASHINGTON,D.C.20006 page of pages CONSTRUCTION CONTROL PROJECT NUMBER: PROJECT TITLE: PROJECT LOCATION: NAME OF BUILDING: NATURE OF PROJECT: �/J/J/T/�A/ G� /C�� C/l,EA�'9 f'r9,Ae'lco 9E j/P/ f,E �T IN ACCORDANCE WITH SECTION 127.0 OF THE MASSACHUSETTS STATE BUILDING CODE, I> L/��£� TJ, �T/�Qy Registration No. /3 BEING A REGISTERED PROFESSIONAL EiiffNEE /ARCHITECT HEREBY CERTIFY THAT I HAVE PREPARED OR DIRECTLY SUPERVISED THE PREPARATION OF ALL DESIGN PLANS, COMPUTATIONS AND SPECIFICA- TIONS CONCERNING: ENTIRE PROJECT ARCHITECTURAL !/ STRUCTURAL -0- FIRE FIRE PROTECTION ELECTRICAL •MECHANICAL OTHER (specify) FOR THE ABOVE NAMED PROJECT AND THAT, TO THE BEST OF MY KNOWLEDGE, SUCH PLANS, COMPUTATIONS AND SPECIFICATIONS MEET THE APPLICABLE PROVISIONS OF THE MASSACHUSETTS STATE BUILDING CODE, ALL ACCEPTABLE ENGINEERING PRACTICES AND APPLICABLE LAWS AND ORDINANCES FOR THE PROPOSED USE AND OCCUPANCY. I FURTHER CERTIFY THAT I SHALL PERFORM THE NECESSARY PROFESSIONAL SERVICES AND BE PRESENT ON THE CONSTRUCTION SITE ON A REGULAR AND PERIODIC BASIS TO DETERMINE THAT THE WORK IS PROCEDING IN ACCORDANCE WITH THE DOCUMENTS APPROVED FOR THE BUILDING PERMIT AND SHALL BE RESPONSIBLE FOR THE FOLLOWING AS SPECIFIED IN SECTION 127.2.2: 1 . Rcvic.. of s tidn-gs5:p p dr , ly i�Fm and cthor citta-s of trw contractor as remised by the construction contract documents as sutmitted for building permit, and approval for conformance to the design concept. 2. Review and approval of the quality control procedures for all code-required controlled materials. 3. Special architectural or engineering professional inspection of critical construction components requiring controlled materials or construction specified in the accepted erigineerinlg practice standards listed in Appendix B. PURSUANT TO SECTION 127.2.3, I SHALL SUBMIT PERIODICALLY, A PROGRESS REPORT TOGETHER WITH PERTINENT COMMENTS TO THE STATE BUILDING INSPECTOR. UPON COMPLETION OF THE WORK, I SHALL SUBMIT A FINAL REPORT AS TO THE SATISFACTORY COMPLETION AND READINESS OF THE PROJECT FOR OCCUPANCY. �4 c: SIGNATURE SUBSCRIBED AND SWORN TP BEFORE ME THIS /-�/ DAY OF 1VyjWKZ1 19 TARY PUBLIC i am L. a oney, � r MY COMMISSION EXPIRES riay 6, 1988 cl< 'I'UL-6-0 P/f 12—/ 7cle g44fft4ND QNB �'?E�156� f'UEL�o D912Y PA2.vNl.� SA V6 NA S7 ZO% 95- 36j 53G,Z76 ± 5.F n°IN I j h . c AcK up t HL OUT IN A/ HZ P SERED qq 35 10, 0"K 20-0 5nactis ,��.5 c".r Z IZ' 0 +C ZO. O o No. 13 9] SALEM h =� MASS. y V� y�<TH OF M-'� Arthur W Rose, P.E.PLLC Structural Engineer 33 South Commercial Street Warichester, NH 03101 (603) 622-6066 (603) 624-2244 Fax Octobei:�'12,"2'007 Mr. Tim McCain Morton Buildings, Inc. 885 Londonderry Turnpike Auburn, NH 03032-1616 Re: Morton Building for Puleo Realty Trust 376 Highland Ave. Salem, MA Morton Job' '# 118-2366 Dear Mr. McCain: This letter report will: corfirm our conversation this date subsequent- to our meeting at the above referenced building site. The purpose of my meeting with you was to review the completed construction of the 60 ft x 12 ft x 120 ft wood framed building structure as designed by Morton Buildings, Inc . Based upon my observations and experience it is my opinion that the wood framing for the building, which is to be occupied bv_ the St . Jean' s Credit Union, has been constructed to date in accordance with the approved Morton Building framing plans and the Commonwealth of Massachusetts State Building Code. Thank you for this opportunity to be of service to you and please do not hesitate to contact me should you have any questions or comments regarding this mat tht y^ t my yours, UR W.OSESTROOTURALhur W. ose, P.E. NO.30734 AWR/zp °9O Q 0o FGISTEPE �`� r' . FSS�ONAL