Loading...
232 HIGHLAND AVENUE - BUILDING INSPECTION Certificate No: Sign Permit No.: 530-05 Commonwealth of Massachusetts OQ City of Salem G Building Electrical Mechanical Permits This is to Certify that the BUSINESS located at -..-._......_....-Dwelling Type .................. 0232 HIGHLAND AVENUE 234 in the CITY OF SALEM ---------------......-..-------------'------ ------------------------ .----------------------------- _------------ ------------ Address TowrvCity Name IS HEREBY GRANTED A PERMANENT CERTIFICATE OF OCCUPANCY Commercial Carwash i I This permit is granted in conformity with the Statutes and ordinances relating thereto,and expires ............_-__ __...... ........... unless sooner suspended or revoked. Expiration Date Issued On:Tue Jul 27,2010 - — --------------------------- - rV G /,���LV1/ GeoTMS®2010 Des Lauriers Municipal Solutions,Inc. ------ -tf+�-- - -TM�'�"'"""'""""-""-"-"""""""-" -- - -- -- X ' ,, /r Ht Y&P_*,qPTA'ND TAPPE INC. ARCHITECTS AND PLANNERS 462 BOYLSTON STREET BOSTON, MASS. 02116 (617) 536-6451 JUL 23 10 5s Pk�i '73 MEMORANDUM RFOCIVPD CITY OF SALE;4,l,;ASS, JOB NO: 7311 ❑ TELEPHONE JOB NAME: HIGHLAND GREEN 91 MEETING DATE: 17 July 1973 L❑ OTHER AT: Office of the Building Inspector City of Salem, Massachusetts Present: Daniel O'Brien, Building Pttspector John R. Serafini, Attorney Frank DiMella Huygens and Tappe' Edward Snow 1 . Mr. Serafini stated that he has been beginning preliminary discussions with each department on this project so as to "break the ice" in an easy, informal manner. 2. Mr. O'Brien said that this was acceptable, however, in the future, meetings should be held with representatives of all affected groups present. H & T, Inc. concurred and agreed to notify Mr. O'Brien several days prior to a proposed meeting date so that he could notify all the groups. he suggested the following list: Fire chief, Building Inspector, Plumbing Inspector, Electrical Inspector, a representative of the Planning Board, the City Engineer, a representative of the Electric Co:, and the Gas Co, and the City Couns-llor re- presenting the area. 3. H & T explained to Mr. O'Brien the siting BOCA code requirements and design of the project. The following comments and questions were raised: a. Where a fire wall is used, it cannot be penetrated between units, but--if it extends beyond or below the abutting section of the units it may be penetrated. " e . doorway below bedroom bridge to lower two (2) B.R, flat. BY. Edward D. Snow �+ •.' DISTRI BUTTON: H & T, Messrs. Serafini, O'Brir_r ` Kaufman and Broad (R. Fish, R Docksel.),._A1ociece�`and Gnry (K.iicFct-Gary)• M, T; F 'x b. H & T will research for backup from wallboard manufacturers on eliminating strapping. C. Mr. O'Brien did not want to immediately comment on possible four (4) story units and will look into them further. d. Mr. O'Brien did state that if four (4) story units are required at a section of an extended building, only that area that is four stories need be constructed to BOCA type 3-B requirements. The change to BOCA type 4-A requirements will be at the nearest firewalls. e. Smoke detectors will be required. f. Mr. O'Brien did not want to immediately comment on the proposed exposed wood frame automobile shelters. He will look into the possibility further. 4. The meeting ended with H & T, Inc. , suggesting a general meeting in approximately two (2) weeks. F I HIGHLAND GREEN - SALEM Job #7311 I. BOCA CODE REQUIREMENTS A. Building use group is classified as L-2, Residential, Multifamily. (BOCA Code Section 210.2). B. In general construction type is 4A, Frame-Protected. (BOCA Code Section 218.0). C. Fire resistance"required for construction type 4A as applied to this project (BOCA Code Table 5). 1 . Exterior Walls, Bearing - 3/4 hour Non bearing at pass through - 3,/4 hour Non bearing - 0 2. Interior Walls, Bearing - 3/4 hour Non Bearing - 0 3. Fire Walls - 2 hours 4. Fire Division (1 ', hours per table 161, but as required by DPS Commissioner Cosgrove if apartments have only one exit - 2 hours 5. Shafts - 3/4 hour 6. Columns and girders - 3,/4 hour 7. Floor construction - 3/4 hour 8. Roof construction - 3/4 hour 9. Structural members supporting wall above. - equal to wall above. D. Maximum height for above construction is three floors/40 feet (BOCA Code Tabel 6). i' w I E. Maximum area between fire walls is 11 ,500 square feet (BOCA Code i Table 6 modified for frontage and height factors). II. BUILDING CONSTRUCTION A. Party (Fire Division) walls, bearing or non-bearing (Meets U.L. Con- struction U301, 2 hours). 1 . 2 x 4 wood studs, staggered, 8" o.c. , firestopped. 2. Two layers 5/8" fire resistive gypsum wallboard (F.R.G .W.B.) on each side. 3. 32" fiberglas in cavity. 4. Single 6" nom. plate. B. Fire Walls, Non-bearing (meets old U.L. Construction designation Design 1-2 hours). 1 . 8" nominal concrete masonry units (CMU), loyed in full bed of cement mortar. 2. Furring as needed each side. 3. '-" G .W.B. each side. 4. No combustible materials used within the CMU face dimension. C. Exterior walls, bearing and at pass through areas (similar to or exceeds U.L. Construction U-317, 3/4 hour). 1 . 2 x 4 wood studs, 16" o.c. , firestopped. 2.. 2" F.R.G.W.B., interior face. 3. }" F.R. Asphalt impregnated gypsum sheathing, exterior face. 4. 3 " fiberalas insulation. 5. Exterior siding (e.g., brick, wood, metal, etc.). If siding is brick, tie back with galvanized corrugated Pies nailed to each stud 16"o.c. vertically. r� D, Exterior Walls, Non-bearing a 1 . 2 x 4 wood studs, 16" o.c. , firestopped. 2. " G .W.B., interior face. I 3. 2" Asphalt impregnated gypsum sheathing, exterior face. 4. 3'"" fiberglas insulation. 5. Exterior siding. E. Interior Bearing Walls (meets U.L. construction U-317, 3/4 hour). 1 . 2 x 4 wood studs, 16" a.c. , fire stopped. 2. F.R.G.W.B., each face. F. Interior Non-bearing Walls 1 . 2 x 3 or 2 x 4 studs 16" o.c. firestopped. 2 G .W B., each face. G. Horizontal separation between apartments (similar to old U.L. construction designation Design 217-2 hrs.) 1 . Wood joists sized as required, 16"' a.c. 2. Two (2) layers 5j8" F.R.G :W.B. at ceiling separated by resilient furring channels 16" o.c. 3. exterior grade plywood subfloor, edge-blocked. 4. Carpeting and/or floor tile. 5. 32" fiberglass acoustical insulation. H . Horizontal separation within apartments (Similar to U.L . Construction L-522 1 hr.). 1 . Wood joists, sized as required, 16" o.c. 2. Strapping. 3. Z" F.R.G.W.B. ceiling. 4. " exterior grade plywood, edge-blocked. 5. Carpeting or floor tile. I . Roof Construction (Similar to U.L. Construction L-515 or FM FC2-1 hr.) 1 . Joists and/or trusses as required. 2. Strapping. 3. F.R.G.W.B. ceiling. 4. 6" Fiberglas insulation. 5. 1," exterior erode plywood, edae-blocked. 6. Mineral granule faced, fire resistant asphaltic shingles. 7. Continuous ridge and air vents. J. Foundations - 10" min. concrete walls on footincs sized per soil capocities. Foundation walls to be reinforced as required. Where necessary, foundation walls and footines shall be designed as ref iinine walls. K. Slabs on grade - 4" min. concrete slobs on b" rain. compacted gravel . 6 mil polyetheline shall be placed below slab. I" x 24" closed cell styrofoam insu- lation laid below slab at all exterior walls. Slabs to be reinforced as required. In general, slabs within units shall be carpeted. III. WHERE BUILDINGS EXCEED THREE STORIES IN HEIGHT A. BOCA Code Requirements 1. Construction type is type 3B, Exterior Masonry wall buildings with interior wood fire protected structural elements (BOCA Code Section 218.2). 2. Fire resistance required for construction type 3B as applied to this project (BOCA Code Table 5). a. Exterior walls, bearing (non combustible) - 2 hours Non-bearing at pass through - 2 hours Non-bearing -0 b. Interior Walls, bearing (non combustible) - 3/4 hour Non-bearing -0 C. Fire Walls (non combusfible) - 2 hours d. Fire Division (non combustible) - 2 hours e. Shafts - 2 hours A f. Columns and girders - 3/4 hour g. Floor construction - 3/4 hour h. Roof Construction - 3/4 hour i. Structural members supporting wall above - equal to wall above 3. Maximum height for above construction is four (4) floors/50ft. (BOCA Code Table b). 4. Maximum area between fire walls is 14,000 square feet (BOCA Code Table b modified for frontage and height factors). 1 9 B. Building Construction .1 . Party (fire division) walls, bearing or non-bearing non combustible construction (meets Factory Mutual construction FM W7-2). a. 3 5/8" steel screw studs 24' o.c. max. R b. Two (2) layers 5/8" F.R.G .W.B. each face, first layer applied vertically, second layer applied horizontally. All F.R.G.W.B. attached with screws. C. 21" fiberglass in cavity. t d. Continuous caulking at top and bottom of each layer of F.R.G.W.B. 2. Fire walls, non-bearing (meets old U.L. construction designation 1-2 hours). a. 8" nom. C.M.U. toyed in full bed of cement mortar, extended T' to footings. e b. Furring and 1" G .W.B. as needed. C. No combustible materials used within the C.M.U. face dimension. 3. Exterior walls, bearing and non-bearing (similar to and meets or exceeds U.L. construction U-301). a. 3 5/8" steel screw studs 16" o,c. b. Two layers 5/8" F.R.G.W — a i id b. 2 ' G.W.B. each face. '9 6. Horizontal separation between apartments (similar to old U.L. construction designation Design 217-2 hours). a. Wood joists sized as required, 16" o.c. b. Two (2) layers 5/8" F.R.G.W.B. at ceiling separated by resilient furring channels 16". o.c. C. 2" exterior grade plywood sub floor, edge blocked. t d 9 d. Low flame spread carpeting and/or floor tile. 9 e. 32" fiberglass acoustical insulation. { 7. Horizontal separation within apartments (Similar to U.L. Construction L-522 I hour). 1 a. Wood joists, sized as required 16" o.c. b. Strapping. c. 2" F.R.G.W.B. ceiling. d, exterior grade plywood, edge-blocked. e. Carpeting or floor tile. 8. Roof Construction (Similar to U. L. Construction L-515 or FM FC2-1 hr.). a. Joists and/or trusses as required. b. Strapping. c. 2 ' F.R.G.W.B. ceiling. d. 6" fiberglass insulation. e. 2" exterior grade plywood, edge-blocked. YUY iSENS 'SNL • • A s Y 9. Foundations: 10" min. concrete walls on footings sized per soil capacities. Foundation walls to be reinforced as required. Where necessary, foundation walls and footings shall be designed as re- taining walls. 10. Slabs on Grade: 4" min. concrete slabs on 6 " min. compacted gravel . 6 mil . polyetheline shall be placed below slab. 1 " x 24" closed cell styrofoam insulation laid below slab at all exterior walls. Slabs to be reinforced as required. In general, slobs within units shall be car- peted. 0d,eo EUILDIHG DEPT S ^ (fttu gponf "intrut, assdjusetts r � APR Z is PZIrf #t ent of Public 3Mvrks �s�wwe mpe 4 �d RALPH w. TCITY OF SALEM,CITY ENGINEERNEER EM,MASS. April 1, 1974 Mr. Daniel O'Brien Inspector of Buildings 5 Broad Street Salem, Mass. Dear Sir: It is the opinion of this office that no further building permits should be issued that would require connec- tions to existing sewers. The suspension of building permits should be continued until the Division of Water Pollution Con- trol releases its directive of November 30, 1973, or grants conditional approvals for entry into the sewer. Application for releases are being made, and pending. Very truly yours, mh ` c.c.Mayor