440 HIGHLAND AVENUE_WALMART_2022_3City of Salem Sign Permit Application Worksheet
Zoning (res/non-res)BPD nonresidential
Entrance Corridor (Y/N)Y
Lot frontage 625 feet
Building or tenant frontage 332 feet
# of businesses on site 2
Bldng dist from street center 100-399 feet
Multiplier 1.25
Building and Blade Signs
maximum area permitted 415.00 sq ft
total proposed sign area 352.32 sq ft
Wall Sign - Walmart 298.40 sq ft
width 447.60 inches
height 96.00 inches
Wall Sign - Pickup 33.32 sq ft
width 117.60 inches
height 40.80 inches
Wall Sign - Pharmacy 20.60 sq ft
width 123.60 inches
height 24.00 inches
Wall Sign - Outdoor 7.14 sq ft
width 61.20
height 16.80
Freestanding Signs
maximum area permitted 65.00 sq ft (per side)
maximum # of signs permitted 2 signs
maximum height permitted 25.00 ft tall
sign 1
proposed sign area 246.50 sq ft
length 408.00 inches
height 87.00 inches
Application meets guidelines set
forth in the Salem Sign Ordinance Yes
Recommend approval Yes
31-Jan-22
Walmart
440 Highland Avenue
Notes:The freestanding sign is a reface of the existing sign. The
proposed nonconforming freestanding signage (proposed area of
signage is larger than typically allowed in an entrance corridor) falls
within the previously approved total proposed sign area.
EXISTING SIGNAGE SCHEDULE NEW SIGNAGE SCHEDULE
TOTAL AREAQTY COLOR
INDIVIDUAL
AREA
1Walmart
SF
WHITE
SIGNAGE LOCATION
FRONT SIGNAGE
SIZE
* (Spark)1 SF SF
LIGHTED
LED
LED YELLOW
5'-6"
8'-0"298.00 298.00
355.85
TOTAL AREAQTY COLOR
INDIVIDUAL
AREA
1
Pickup
Walmart
SF SF
1
1
WHITE
WHITE
WHITE
SIGNAGE LOCATION
FRONT SIGNAGE
SIZE
* (Spark)1
LIGHTED
LED
LED
LED
N/A
YELLOW
4'-3"
8'-0"
2'-6"
2'-0" 20.50 20.50
SF SF32.22 32.22
N/A
Outdoor
TOTAL FRONT SIGNAGE SF359.61
Outdoor Living
TOTAL FRONT SIGNAGE
1
1
WHITE
WHITEN/A 2'-0"
1'-0"
SF SF49.47 49.47
Pharmacy
SF299.04 SF299.04
SF SF8.38 8.38 SF SF1WHITEN/A 1'-0" 7.85 7.85Pharmacy
299.04 SF
1'-3"
5'-6"
8'-0"
28'-7 1/2"1'-6"7'-1 1/2"
37'-3"
INTERNALLY ILLUMINATED
T Y P
6 0 °
T Y P2'-7 3 /8 "
WHITE PLASTIC LETTERS
32.22 SF
3'-4"
2'-6"
9'-8"
INTERNALLY
ILLUMINATED
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING
THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS,
CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN
AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE.
PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES.
NOTE:
ALL SIGN PENETRATIONS ABOVE
ROOF LEVEL MUST BE A CLEAR
MINIMUM OF 8" ABOVE DECK
6
A2.1
_______
20.50 SF
2' - 0"
10' - 3"
7
A2.1
_______
7.85 SF
1'-4 1/8"
1'-0"
5'-10 1/8"
7
A2.1
_______
SIGNAGE GENERAL NOTES
1.
2.
A.
B.
C.
3.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
SIGNAGE FURNISHED BY WALMART AND INSTALLED BY GC.
ALL EXISTING WALMART EXTERIOR SIGNAGE IS TO REMAIN IN PLACE ON THE
BUILDING UNTIL THE GC SIGN COMPANY IS ONSITE. THE EXISTING SIGNAGE WILL
THEN BE REMOVED, PATCH AND REPAIR WORK WILL BE COMPLETED AT SIGN
LOCATIONS, AND NEW SIGNAGE WILL BE INSTALLED PER PLANS.
A TEMPORARY BANNER WILL BE INSTALLED PRIOR TO REMOVAL OF EXISTING
EXTERIOR SIGNAGE. BANNER WILL REMAIN IN PLACE UNTIL ALL MODIFICATIONS
AND/OR REPAIRS HAVE BEEN COMPLETED AND NEW SIGNAGE IS INSTALLED.
TEMPORARY BANNER WILL BE APPROXIMATELY 125 SF (5'X25').
EXTERIOR SIGN WORK NEEDS TO BE SCHEDULED, COORDINATED, AND
COMPLETED DURING WEEK 6 OF THE CONSTRUCTION SCHEDULE.
GENERAL CONTRACTOR RESPONSIBILITIES
BY END OF FIRST WEEK OF CONSTRUCTION, REVIEW EXISTING CONSTRUCTION
WHERE SIGN(S) WILL BE INSTALLED. IF EXISTING CONDITIONS DO NOT MATCH
SIGN ATTACHMENT DETAILS SHOWN, REQUEST APPROVAL FROM CONSTRUCTION
MANAGER TO SUBMIT RFI IN ACCORDANCE WITH SECTION 01255. NOTE
DIFFERENCES IN CONSTRUCTION, INCLUDING DIMENSIONS, AND INCLUDE
PHOTOGRAPHS FOR CLARIFICATION.
PROVIDE SUBSTRATE SUITABLE FOR INSTALLATION OF SIGNAGE. REFER TO SIGN
DETAILS FOR LIGHTED ID/LOGO SIGNS.
PROVIDE JUNCTION BOXES AND CIRCUITRY TO NEW "Walmart" and "spark"
SIGNAGE. EXISTING BOXES FROM "WALMART" SIGNAGE MAY BE REUSED.
PROVIDE JUNCTION BOXES AND CIRCUITRY TO TENANT SIGNAGE LOCATION
SHOWN. REFER TO ELECTRICAL.
INSTALL ACCESS DOORS AND FRAMES IN GYPSUM BOARD CEILINGS IF REQUIRED
BY RELOCATION OF EXISTING TENANT SIGNAGE.
VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED SIGNAGE. REFER TO
ELECTRICAL
MAKE FINAL TERMINATIONS ON LIGHTED SIGNAGE.
REMOVE ALL LIT ID/LOGO SIGNS AND UNLIT EXTERIOR STUD MOUNTED BUILDING
SIGNS. UNLESS NOTED OTHERWISE.
MAKE REQUIRED EXTERIOR WALL PENETRATIONS, INSTALL CONDUIT, AND SEAL
PENETRATIONS PER SPECIFICATION SECTION 07900.
INSTALL SIGNAGE PER DETAILS.
REF CIVIL PLANS
FOR SIGN
LOCATION
EXISTING LIGHT
POLE
2'-0"
5'-0"
18'-0"
WHITE LETTERS
FLEX FACE, COLOR
PMS 285C BLUE
YELLOW SPARK,
COLOR PMS 1235C
REPLACE FACE ON
EXISTING SIGN
EXISTING SIGN
SUPPORTS
FV
FV
ILLUMINATED SIGN
INFORMATION
SIGN BACKING MATERIAL: .80 ALUMINUM
3105 h14 00-A-250/2-ASTM-B209
WEIGHT OF LETTERS (IN LBS):
5'-6" SIGN
w 70
a 40
l 25
m 55
a 40
r 25
t 30
spark 15
REF BLDG EL
BO SIGNAGE
1/2" ALL-THREAD CUT TO WITHIN
1/4" OF NUT AND GRIND END
SMOOTH, TYP
SIGN CAN WITH
.080 ALUMINUM BACKING
FULL BED OF
MULTI-COMPONENT SEALANT
AT PERIMETER OF CONDUIT
DRILL HOLE AND FEED
WHIP THROUGH PARAPET
EXISTING WATERPROOFING
MEMBRANE
SEALANT AT PERIMETER AND
ANCHORS OF REMOTE
POWER SUPPLY ENCLOSURE
EXISTING FRAMING
EXISTING ROOFING
SYSTEM
EXISTING EXTERIOR PLYWOOD
SHEATHING
1" OD NEOPRENE/SS BONDED
WASHER PROVIDED BY WALMART
IN BED OF CONTINUOUS
MULTI-COMPONENT SEALANT BY
GC
FULL BED OF
MULTI-COMPONENT SEALANT
AT PERIMETER OF SPACER, TYP
PVC SPACER TO PREVENT
COMPRESSION OF EIFS, 3/4"
OUTER DIAMETER AND 5/8"
INSIDE DIAMETER, TYP
5/8" EXTERIOR PLYWOOD
SHEATHING
EXISTING
PLYWOOD
SHEATHING
NOTE:
LOCATE ALL-THREADS PER SIGN
ATTACHMENT TEMPLATE.
EXISTING EIFS
REFER TO SIGNAGE
GENERAL
NOTES FOR ADDITIONAL
REQUIREMENTS
REMOTE POWER SUPPLY
ENCLOSURE
LOW VOLTAGE WIRE
SEALANT AT PERIMETER AND
ANCHORS OF REMOTE
POWER SUPPLY ENCLOSURE
3/4" LIQUID TIGHT FLEXIBLE
METAL CONDUIT
REF FOR ROOF
PENETRATION DETAIL
SEALANT AT LOW VOLTAGE
WIRE PENETRATIONS
MEMBRANE PATCH OVER
FASTENER CONNECTION
(2) LAYERS OF MEMBRANE
UNDER NUT AND WASHER
THROUGH WALL
PROTECTION TUBE.
INSTALL PER MFR
RECOMMENDATIONS
3' TO 4' ABOVE ROOF SURFACE
TOP OF PARAPET
12" MIN
PREFERRED MOUNTING HEIGHT
12" MIN
8" MIN
IF WALL CAVITY IS
INACCESSIBLE USE
LIBERTY ANCHOR:
THROUGH WALL
PROTECTION TUBE
FURNISHED BY WALMART
INSTALLED BY GC PER
MFR RECOMMENDATIONS
FULL BED OF MULTI-
COMPONENT SEALANT AT
PERIMETER OF CONDUIT
INSTALL LETTER BACK
PRIOR TO INSTALLATION
INDIVIDUAL PLASTIC
ILLUMINATED CHANNEL
LETTERS
INSTALL LETTER FACES
W/ SET SCREWS, TYP
LOCATE ANCHORS AND
WIRING/CONDUIT PENETRATIONS
PER SIGN ATTACHMENT TEMPLATE
PROVIDED BY WALMART
SEALANT ALL AROUND
ELECTRICAL TO
JUNCTION BOX
REMOTE POWER SUPPLY
ENCLOSURE
HILTI HPS 1/4" X 1 5/8"
SLEEVE ANCHOR
PROVIDED BY WALMART
AT EACH SIGN
CONNECTION POINT
INSTALLED BY GC
LOW VOLTAGE WIRE
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING THROUGH PRIMARY HOLE IS
OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY
HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE.
PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE
HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.
ELECTRICAL PENETRATIONS
(TYP) FIELD VERIFY EXACT
LOCATIONS
ALTERNATE SIGN
MOUNTING LOCATION (TYP)
FIELD VERIFY EXACT
LOCATIONS
SIGN MOUNTING
LOCATION (TYP) FIELD
VERIFY EXACT
LOCATIONS
ROOF LINE
JOIST BEARING
ELEVATION LINE
REF BLDG ELEVATIONS
BO SIGN
NOTE:
ALL SIGN PENETRATIONS
ABOVE ROOF LEVEL MUST BE A
CLEAR MINIMUM OF 8" ABOVE
DECK
5
A2.1
_______
EXISTING
FRAMING
PLASTIC NON-ILLUMINATED
CHANNEL LETTER
PLASTIC MOUNT FOR
ALL-THREAD STUD,
TYP
INSTALL 1/8" DIA ALL-
THREAD STUDS INTO
PLASTIC MOUNTS, TYP
3/8" DIA HOLE FILLED
WITH ADHESIVE
SEALANT, TYP
MOUNTING HOLE PATTERNS FOR NON-
ILLUMINATED SIGN INSTALLATION
PROVIDED BY WALMART
"ADHESIVE SEALANT" IS TO BE
PRODUCT LN-950 BY LIQUID NAILS OR
SIMILAR POLYURETHANE
CONSTRUCTION ADHESIVE, MEETING
ASTM D3498 AND C557 STANDARDS,
EXTERIOR APPLICATION, WEATHER
RESISTANT, LOW VOC, WITH A
MINIMUM SHEAR STRENGTH OF 250
PSI
PRIOR TO PERFORMING THIS WORK,
VERIFY EXISTING SUBSTRATE
MATERIAL. IF EXISTING SUBSTRATE IS
CMU OR PLYWOOD (5/8" OR THICKER),
SUBSTRATE REPLACEMENT IS NOT
REQ'D
VARIES
REFER TO SIGNAGE
GENERAL
NOTES FOR ADDITIONAL
REQUIREMENTS
1/4" SPACER BETWEEN
FACE OF BUILDING
FINISH AND CHANNEL
LETTER
architecture
2809 Ajax Avenue Suite 100
Rogers Arkansas 72758
Phone: 479.636.3545
Fax: 479.636.1209
+engineering
Architect of Record
William Douglas Hurley
Massachusetts License No. 10506
STIPULATION FOR REUSE
THIS DRAWING WAS PREPARED FOR
USE ON A SPECIFIC SITE AT:
CONTEMPORANEOUSLY WITH ITS ISSUE
DATE ON AND IT IS NOT
SUITABLE FOR USE ON A DIFFERENT
PROJECT SITE OR AT A LATER TIME. USE
OF THIS DRAWING FOR REFERENCE OR
EXAMPLE ON ANOTHER PROJECT
REQUIRES THE SERVICES OF PROPERLY
LICENSED ARCHITECTS AND ENGINEERS.
REPRODUCTION OF THIS DRAWING FOR
REUSE ON ANOTHER PROJECT IS NOT
AUTHORIZED AND MAY BE CONTRARY TO
THE LAW.
DRAWN BY:
CHECKED BY:
DOCUMENT DATE:
PROTO:
PROTO CYCLE:
DOCUMENTS THAT DO NOT
HAVE THE ARCHITECT OR
ENGINEER OF RECORD SEAL
AND SIGNATURE SHALL BE
CONSIDERED NOT FOR
CONSTRUCTION
SHEET:
ISSUE BLOCK
PROTO:
2022 SUPER BUNDLE
SALEM, MASSACHUSETTS
01/18/22
CS
SL
DIV1
10/29/21
01/18/22
EXTERIOR
SIGNAGE
A2.1
SALEM, MASSACHUSETTS
STORE NO.2640-233
JOB NUMBER: 2021.1165
DIV1
450 HIGHLAND AVE
1/4" = 1'-0"1 5'-6" WALMART SIGN
1/4" = 1'-0"2 2'-6" PICKUP
1/4" = 1'-0"3 2'-0" OUTDOOR
1/4" = 1'-0"4 1'-0" PHARMACY
3/16" = 1'-0"8
TEMPORARY PICKUP BANNER
AT EXISTING LIGHT POLE
3/16" = 1'-0"9 MULTI-TENANT SIGN
1 1/2" = 1'-0"5 SIGN ATTACHMENT AT EIFS ABOVE ROOF LINE
1 1/2" = 1'-0"6 SIGNAGE ATTACHMENT
1/4" = 1'-0"1A 5'-6" WALMART SIGN MOUNTING DIAGRAM
1 1/2" = 1'-0"7
SIGN ATTACHMENT AT EIFS
AND METAL STUD WALL
BCommonwealth of Massachusetts
City of Salem
120 Washington St, 3rd Floor Salem, MA 01970 (978) 745-9595 x5641
Permit No. SP-22-5
FEE PAID: $55.00
DATE ISSUED: March 10, 2022 PERMIT TO BUILD SIGN Expiration Date: September 10, 2022
This certifies
that:
Jennifer Paquin
has permission to erect a
sign(s) on :440 HIGHLAND AVENUE Map/Lot #: 03-0004-0
Detailed as
follows:Sign #1:Free Standing,
Contractor Name: Philadelphia Sign Co
DBA:
Installer:
Building Official :
Issued Date: March 10,
2022
This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six months after issuance. The Building Official may grant one or
more extensions not to exceed six months each upon written request.
All work authorized by this permit shall conform to the approved application and the approved construction documents for which this permit has been granted.
All construction, alterations and changes of use of any building and structures shall be in compliance with the local zoning by-laws and codes.
This permit shall be displayed in a location clearly visible from access street or road and shall be maintained open for public inspection for the entire duration of the work until the
completion of the same.
HIC #:
Restrictions:
BBuilding plans are to be available on site.
All Permit Cards are the property of the PROPERTY OWNER.