440 HIGHLAND AVENUE_WALMART_2022_1City of Salem Sign Permit Application Worksheet
Zoning (res/non-res)BPD nonresidential
Entrance Corridor (Y/N)Y
Lot frontage 625 feet
Building or tenant frontage 332 feet
# of businesses on site 2
Bldng dist from street center 100-399 feet
Multiplier 1.25
Building and Blade Signs
maximum area permitted 415.00 sq ft
total proposed sign area 352.32 sq ft
Wall Sign - Walmart 298.40 sq ft
width 447.60 inches
height 96.00 inches
Wall Sign - Pickup 33.32 sq ft
width 117.60 inches
height 40.80 inches
Wall Sign - Pharmacy 20.60 sq ft
width 123.60 inches
height 24.00 inches
Wall Sign - Outdoor 7.14 sq ft
width 61.20
height 16.80
Freestanding Signs
maximum area permitted 65.00 sq ft (per side)
maximum # of signs permitted 2 signs
maximum height permitted 25.00 ft tall
sign 1
proposed sign area 246.50 sq ft
length 408.00 inches
height 87.00 inches
Application meets guidelines set
forth in the Salem Sign Ordinance Yes
Recommend approval Yes
31-Jan-22
Walmart
440 Highland Avenue
Notes:The freestanding sign is a reface of the existing sign. The
proposed nonconforming freestanding signage (proposed area of
signage is larger than typically allowed in an entrance corridor) falls
within the previously approved total proposed sign area.
SHEET NOTES
P5E
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
PATCH AND REPAIR EXTERIOR WALL SURFACES, DAMAGED OR EXPOSED DUE TO
REMOVAL OF BUILDING MOUNTED ITEMS, TO MATCH ADJACENT AS REQUIRED.
REFER TO DETAILS ON SHEET A2.1 FOR SUBSTRATE AND FINISH REQUIREMENTS AT
LOCATIONS OF BUILDING MOUNTED SIGNS.
RESURFACE EXISTING EIFS WHERE SHOWN ON ELEVATIONS.
NOT USED.
PRIOR TO PAINTING WALL AT LOCATION(S) OF LIT ID/LOGO SIGN(S), COORDINATE SCOPE
OF WORK WITH WALMART CM.
IF PAINTING ADJACENT PAINT HOLLOW METAL STEEL DOORS, FRAMES, AND
DOWNSPOUTS, EXPOSED METAL FLASHING, HANDRAILS, AND EXPOSED
MISCELLANEOUS STEEL TO MATCH ADJACENT BUILDING COLOR UNO.
PAINT ANY NEW ROOFTOP GAS PIPING WHERE EXTERIOR WALL IS BEING
PAINTED, GAS PIPE ALONG SIDE WALL TO GRADE SHOULD MATCH ADJACENT BUILDING.
DO NOT PAINT METER OR VALVES.
IF PAINTING ADJACENT WALLS PAINT CANOPY STRUCTURAL STEEL AND FLASHING TO
MATCH ADJACENT WALL.
WHERE CANOPIES ARE VISIBLE TO AND ACCESSED BY CUSTOMERS, PAINT UNDERSIDE
OF CANOPY DECK DO NOT PAINT CANOPY DECK IF NOT PREVIOUSLY PAINTED.
PAINT ALL EXTERIOR BOLLARDS TO MATCH EXISTING COLOR UNLESS NOTED TO
RECEIVE PLASTIC BOLLARD SLEEVE.
NOT USED.
DO NOT PAINT LED WALL PACK HOUSINGS.
NOT USED.
NOT USED.
NOT USED.
NOT USED.
REF 9 - A2.1 FOR REFACING THE WALMART SIGN ON THE EXISTING MULTI-TENANT PYLON
SIGN.
P33E
COLOR LEGEND
LIGHT GRAY
BLACK
WALMART BLUE (URETHANE-LIKE)
MEDIUM GRAY
COLOR NAME
P81E
P#
P76U
P134E
P135E
BLACK GRAYP162E
DARK GRAYP49E
DOMINOP36E
SAFETY REDP21E
SAFETY YELLOW OSHA STANDARDP5E
DOVER WHITEP33E
12345678910
P135E P49EP135EP134E P49E P135E P134E P135E
P134E
P135EP134E
2' - 0"
NEW SIGN
REF 2 - A2.1
P76U
NEW SIGN
REF 3 - A2.1
P134E
P49E
P134E P49E
P49E
P134E P134E
DOORS
CAP CAP
P134E P134EFENCING SHOWN DASHED FOR CLARITY.
P162E
CANOPY
NEW SIGN
REF 1 - A2.1 P76UP134E
CAP
P135E
ADJACENT BUILDING
EXISTING ADDRESS DIGITS TO BE REPLACED
WITH NEW BOGLE FONT DIGITS. INSTALL
NEW DIGITS AT ALL EXISTING LOCATIONS.
10'-0"
10"
P134E P134E
CAP CAP
10' - 0"
EQ
EQ
NEW SIGN
REF 4 - A2.1
EQ EQ
11' - 2"20' - 0"
NEW PICKUP
DOOR
P135E
20' - 0"
P135E
20' - 0"
1 2 3 4 5 6 7 8 9 10
FENCING SHOWN DASHED FOR CLARITY.
P134E P134E
P134E P134E
P134E
P134E P134EP134E
P134E P134E
P134E P134E P134E
P162E
ADJACENT BUILDING
CAP
CAP
CAP CAP
CANOPY
DOOR
HOOD
DOOR DOOR DOORS
P134E
ABCDEFGHJKLMNOPQRS
P49EP134EP134EP134EP134EP134EP134E
P134E
P162E
P76U
P134E
CANOPY
P134E
P134EP134EP134E
CAP
CAPCAP
DOOR
CAP
GARDEN CENTER FENCING
SHOWN DASHED FOR CLARITY.
P134EP134E
CAP CAP
P134E
CAP
P134E
A B C D E F G H J K L M N O P Q R S
FENCING SHOWN DASHED FOR CLARITY.
P134E P134EP134E P134EP134EP134EP49E
P162E
P134E
P76U
CANOPY
FENCING SHOWN
DASHED FOR CLARITY DOORS DOORS DOOR
ADJACENT BUILDING
CAP
P49E
P134E P134E
CAP
P134E
P134E
CAP
CAP
P134E
DOOR
HOOD
DEMOLITION NOTES
1.
2.
NOT USED.
REMOVAL OF BUILDING MOUNTED ITEMS, SHOWN OR
NOTED TO BE DEMOLISHED OR AS REQUIRED BY SCOPE
OF WORK, SHALL OCCUR PRIOR TO PAINTING BUILDING.
COORDINATE DEMOLITION WORK SO EXTERIOR
PAINTING WILL OCCUR PRIOR TO INSTALLATION OF
BUILDING MOUNTED ITEMS.
architecture
2809 Ajax Avenue Suite 100
Rogers Arkansas 72758
Phone: 479.636.3545
Fax: 479.636.1209
+engineering
Architect of Record
William Douglas Hurley
Massachusetts License No. 10506
STIPULATION FOR REUSE
THIS DRAWING WAS PREPARED FOR
USE ON A SPECIFIC SITE AT:
CONTEMPORANEOUSLY WITH ITS ISSUE
DATE ON AND IT IS NOT
SUITABLE FOR USE ON A DIFFERENT
PROJECT SITE OR AT A LATER TIME. USE
OF THIS DRAWING FOR REFERENCE OR
EXAMPLE ON ANOTHER PROJECT
REQUIRES THE SERVICES OF PROPERLY
LICENSED ARCHITECTS AND ENGINEERS.
REPRODUCTION OF THIS DRAWING FOR
REUSE ON ANOTHER PROJECT IS NOT
AUTHORIZED AND MAY BE CONTRARY TO
THE LAW.
DRAWN BY:
CHECKED BY:
DOCUMENT DATE:
PROTO:
PROTO CYCLE:
DOCUMENTS THAT DO NOT
HAVE THE ARCHITECT OR
ENGINEER OF RECORD SEAL
AND SIGNATURE SHALL BE
CONSIDERED NOT FOR
CONSTRUCTION
SHEET:
ISSUE BLOCK
PROTO:
2022 SUPER BUNDLE
C:\Users\corysimons\Documents\2640_Salem_MA_L_96_ARCH_V20_cory.simons@pb2ae.com.rvt
SALEM, MASSACHUSETTS
01/18/22
CL/CS
SL
DIV1
10/29/21
01/18/22
EXTERIOR
ELEVATIONS
A2
SALEM, MASSACHUSETTS
STORE NO.2640-233
JOB NUMBER: 2021.1165
DIV1
450 HIGHLAND AVE
1/16" = 1'-0"1 FRONT ELEVATION
1/16" = 1'-0"2 REAR ELEVATION
1/16" = 1'-0"3 LEFT ELEVATION
1/16" = 1'-0"4 RIGHT ELEVATION
EXISTING SIGNAGE SCHEDULE NEW SIGNAGE SCHEDULE
TOTAL AREAQTY COLOR
INDIVIDUAL
AREA
1Walmart
SF
WHITE
SIGNAGE LOCATION
FRONT SIGNAGE
SIZE
* (Spark)1 SF SF
LIGHTED
LED
LED YELLOW
5'-6"
8'-0"298.00 298.00
355.85
TOTAL AREAQTY COLOR
INDIVIDUAL
AREA
1
Pickup
Walmart
SF SF
1
1
WHITE
WHITE
WHITE
SIGNAGE LOCATION
FRONT SIGNAGE
SIZE
* (Spark)1
LIGHTED
LED
LED
LED
N/A
YELLOW
4'-3"
8'-0"
2'-6"
2'-0" 20.50 20.50
SF SF32.22 32.22
N/A
Outdoor
TOTAL FRONT SIGNAGE SF359.61
Outdoor Living
TOTAL FRONT SIGNAGE
1
1
WHITE
WHITEN/A 2'-0"
1'-0"
SF SF49.47 49.47
Pharmacy
SF299.04 SF299.04
SF SF8.38 8.38 SF SF1WHITEN/A 1'-0" 7.85 7.85Pharmacy
299.04 SF
1'-3"
5'-6"
8'-0"
28'-7 1/2"1'-6"7'-1 1/2"
37'-3"
INTERNALLY ILLUMINATED
T Y P
6 0 °
T Y P2'-7 3 /8 "
WHITE PLASTIC LETTERS
32.22 SF
3'-4"
2'-6"
9'-8"
INTERNALLY
ILLUMINATED
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING
THROUGH PRIMARY HOLE IS OBSTRUCTED BY REBAR, METAL STUDS,
CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY HOLE IN SIGN CAN
AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE.
PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES.
NOTE:
ALL SIGN PENETRATIONS ABOVE
ROOF LEVEL MUST BE A CLEAR
MINIMUM OF 8" ABOVE DECK
6
A2.1
_______
20.50 SF
2' - 0"
10' - 3"
7
A2.1
_______
7.85 SF
1'-4 1/8"
1'-0"
5'-10 1/8"
7
A2.1
_______
SIGNAGE GENERAL NOTES
1.
2.
A.
B.
C.
3.
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
SIGNAGE FURNISHED BY WALMART AND INSTALLED BY GC.
ALL EXISTING WALMART EXTERIOR SIGNAGE IS TO REMAIN IN PLACE ON THE
BUILDING UNTIL THE GC SIGN COMPANY IS ONSITE. THE EXISTING SIGNAGE WILL
THEN BE REMOVED, PATCH AND REPAIR WORK WILL BE COMPLETED AT SIGN
LOCATIONS, AND NEW SIGNAGE WILL BE INSTALLED PER PLANS.
A TEMPORARY BANNER WILL BE INSTALLED PRIOR TO REMOVAL OF EXISTING
EXTERIOR SIGNAGE. BANNER WILL REMAIN IN PLACE UNTIL ALL MODIFICATIONS
AND/OR REPAIRS HAVE BEEN COMPLETED AND NEW SIGNAGE IS INSTALLED.
TEMPORARY BANNER WILL BE APPROXIMATELY 125 SF (5'X25').
EXTERIOR SIGN WORK NEEDS TO BE SCHEDULED, COORDINATED, AND
COMPLETED DURING WEEK 6 OF THE CONSTRUCTION SCHEDULE.
GENERAL CONTRACTOR RESPONSIBILITIES
BY END OF FIRST WEEK OF CONSTRUCTION, REVIEW EXISTING CONSTRUCTION
WHERE SIGN(S) WILL BE INSTALLED. IF EXISTING CONDITIONS DO NOT MATCH
SIGN ATTACHMENT DETAILS SHOWN, REQUEST APPROVAL FROM CONSTRUCTION
MANAGER TO SUBMIT RFI IN ACCORDANCE WITH SECTION 01255. NOTE
DIFFERENCES IN CONSTRUCTION, INCLUDING DIMENSIONS, AND INCLUDE
PHOTOGRAPHS FOR CLARIFICATION.
PROVIDE SUBSTRATE SUITABLE FOR INSTALLATION OF SIGNAGE. REFER TO SIGN
DETAILS FOR LIGHTED ID/LOGO SIGNS.
PROVIDE JUNCTION BOXES AND CIRCUITRY TO NEW "Walmart" and "spark"
SIGNAGE. EXISTING BOXES FROM "WALMART" SIGNAGE MAY BE REUSED.
PROVIDE JUNCTION BOXES AND CIRCUITRY TO TENANT SIGNAGE LOCATION
SHOWN. REFER TO ELECTRICAL.
INSTALL ACCESS DOORS AND FRAMES IN GYPSUM BOARD CEILINGS IF REQUIRED
BY RELOCATION OF EXISTING TENANT SIGNAGE.
VERIFY VOLTAGE AT CIRCUITS FEEDING LIGHTED SIGNAGE. REFER TO
ELECTRICAL
MAKE FINAL TERMINATIONS ON LIGHTED SIGNAGE.
REMOVE ALL LIT ID/LOGO SIGNS AND UNLIT EXTERIOR STUD MOUNTED BUILDING
SIGNS. UNLESS NOTED OTHERWISE.
MAKE REQUIRED EXTERIOR WALL PENETRATIONS, INSTALL CONDUIT, AND SEAL
PENETRATIONS PER SPECIFICATION SECTION 07900.
INSTALL SIGNAGE PER DETAILS.
REF CIVIL PLANS
FOR SIGN
LOCATION
EXISTING LIGHT
POLE
2'-0"
5'-0"
18'-0"
WHITE LETTERS
FLEX FACE, COLOR
PMS 285C BLUE
YELLOW SPARK,
COLOR PMS 1235C
REPLACE FACE ON
EXISTING SIGN
EXISTING SIGN
SUPPORTS
FV
FV
ILLUMINATED SIGN
INFORMATION
SIGN BACKING MATERIAL: .80 ALUMINUM
3105 h14 00-A-250/2-ASTM-B209
WEIGHT OF LETTERS (IN LBS):
5'-6" SIGN
w 70
a 40
l 25
m 55
a 40
r 25
t 30
spark 15
REF BLDG EL
BO SIGNAGE
1/2" ALL-THREAD CUT TO WITHIN
1/4" OF NUT AND GRIND END
SMOOTH, TYP
SIGN CAN WITH
.080 ALUMINUM BACKING
FULL BED OF
MULTI-COMPONENT SEALANT
AT PERIMETER OF CONDUIT
DRILL HOLE AND FEED
WHIP THROUGH PARAPET
EXISTING WATERPROOFING
MEMBRANE
SEALANT AT PERIMETER AND
ANCHORS OF REMOTE
POWER SUPPLY ENCLOSURE
EXISTING FRAMING
EXISTING ROOFING
SYSTEM
EXISTING EXTERIOR PLYWOOD
SHEATHING
1" OD NEOPRENE/SS BONDED
WASHER PROVIDED BY WALMART
IN BED OF CONTINUOUS
MULTI-COMPONENT SEALANT BY
GC
FULL BED OF
MULTI-COMPONENT SEALANT
AT PERIMETER OF SPACER, TYP
PVC SPACER TO PREVENT
COMPRESSION OF EIFS, 3/4"
OUTER DIAMETER AND 5/8"
INSIDE DIAMETER, TYP
5/8" EXTERIOR PLYWOOD
SHEATHING
EXISTING
PLYWOOD
SHEATHING
NOTE:
LOCATE ALL-THREADS PER SIGN
ATTACHMENT TEMPLATE.
EXISTING EIFS
REFER TO SIGNAGE
GENERAL
NOTES FOR ADDITIONAL
REQUIREMENTS
REMOTE POWER SUPPLY
ENCLOSURE
LOW VOLTAGE WIRE
SEALANT AT PERIMETER AND
ANCHORS OF REMOTE
POWER SUPPLY ENCLOSURE
3/4" LIQUID TIGHT FLEXIBLE
METAL CONDUIT
REF FOR ROOF
PENETRATION DETAIL
SEALANT AT LOW VOLTAGE
WIRE PENETRATIONS
MEMBRANE PATCH OVER
FASTENER CONNECTION
(2) LAYERS OF MEMBRANE
UNDER NUT AND WASHER
THROUGH WALL
PROTECTION TUBE.
INSTALL PER MFR
RECOMMENDATIONS
3' TO 4' ABOVE ROOF SURFACE
TOP OF PARAPET
12" MIN
PREFERRED MOUNTING HEIGHT
12" MIN
8" MIN
IF WALL CAVITY IS
INACCESSIBLE USE
LIBERTY ANCHOR:
THROUGH WALL
PROTECTION TUBE
FURNISHED BY WALMART
INSTALLED BY GC PER
MFR RECOMMENDATIONS
FULL BED OF MULTI-
COMPONENT SEALANT AT
PERIMETER OF CONDUIT
INSTALL LETTER BACK
PRIOR TO INSTALLATION
INDIVIDUAL PLASTIC
ILLUMINATED CHANNEL
LETTERS
INSTALL LETTER FACES
W/ SET SCREWS, TYP
LOCATE ANCHORS AND
WIRING/CONDUIT PENETRATIONS
PER SIGN ATTACHMENT TEMPLATE
PROVIDED BY WALMART
SEALANT ALL AROUND
ELECTRICAL TO
JUNCTION BOX
REMOTE POWER SUPPLY
ENCLOSURE
HILTI HPS 1/4" X 1 5/8"
SLEEVE ANCHOR
PROVIDED BY WALMART
AT EACH SIGN
CONNECTION POINT
INSTALLED BY GC
LOW VOLTAGE WIRE
NOTE TO SIGN INSTALLER:
ALL PRIMARY MOUNTING HOLES MUST BE UTILIZED . IF MOUNTING THROUGH PRIMARY HOLE IS
OBSTRUCTED BY REBAR, METAL STUDS, CHANNELS, OR OTHER MISC METAL, SEAL PRIMARY
HOLE IN SIGN CAN AND MOUNT THROUGH THE NEAREST ALTERNATE MOUNTING HOLE.
PRIMARY HOLES ARE INDICATED WITH PREDRILLED HOLES THROUGH WASHERS. ALTERNATE
HOLES ARE INDICATED WITH WASHERS ONLY OR ARE OTHERWISE MARKED.
ELECTRICAL PENETRATIONS
(TYP) FIELD VERIFY EXACT
LOCATIONS
ALTERNATE SIGN
MOUNTING LOCATION (TYP)
FIELD VERIFY EXACT
LOCATIONS
SIGN MOUNTING
LOCATION (TYP) FIELD
VERIFY EXACT
LOCATIONS
ROOF LINE
JOIST BEARING
ELEVATION LINE
REF BLDG ELEVATIONS
BO SIGN
NOTE:
ALL SIGN PENETRATIONS
ABOVE ROOF LEVEL MUST BE A
CLEAR MINIMUM OF 8" ABOVE
DECK
5
A2.1
_______
EXISTING
FRAMING
PLASTIC NON-ILLUMINATED
CHANNEL LETTER
PLASTIC MOUNT FOR
ALL-THREAD STUD,
TYP
INSTALL 1/8" DIA ALL-
THREAD STUDS INTO
PLASTIC MOUNTS, TYP
3/8" DIA HOLE FILLED
WITH ADHESIVE
SEALANT, TYP
MOUNTING HOLE PATTERNS FOR NON-
ILLUMINATED SIGN INSTALLATION
PROVIDED BY WALMART
"ADHESIVE SEALANT" IS TO BE
PRODUCT LN-950 BY LIQUID NAILS OR
SIMILAR POLYURETHANE
CONSTRUCTION ADHESIVE, MEETING
ASTM D3498 AND C557 STANDARDS,
EXTERIOR APPLICATION, WEATHER
RESISTANT, LOW VOC, WITH A
MINIMUM SHEAR STRENGTH OF 250
PSI
PRIOR TO PERFORMING THIS WORK,
VERIFY EXISTING SUBSTRATE
MATERIAL. IF EXISTING SUBSTRATE IS
CMU OR PLYWOOD (5/8" OR THICKER),
SUBSTRATE REPLACEMENT IS NOT
REQ'D
VARIES
REFER TO SIGNAGE
GENERAL
NOTES FOR ADDITIONAL
REQUIREMENTS
1/4" SPACER BETWEEN
FACE OF BUILDING
FINISH AND CHANNEL
LETTER
architecture
2809 Ajax Avenue Suite 100
Rogers Arkansas 72758
Phone: 479.636.3545
Fax: 479.636.1209
+engineering
Architect of Record
William Douglas Hurley
Massachusetts License No. 10506
STIPULATION FOR REUSE
THIS DRAWING WAS PREPARED FOR
USE ON A SPECIFIC SITE AT:
CONTEMPORANEOUSLY WITH ITS ISSUE
DATE ON AND IT IS NOT
SUITABLE FOR USE ON A DIFFERENT
PROJECT SITE OR AT A LATER TIME. USE
OF THIS DRAWING FOR REFERENCE OR
EXAMPLE ON ANOTHER PROJECT
REQUIRES THE SERVICES OF PROPERLY
LICENSED ARCHITECTS AND ENGINEERS.
REPRODUCTION OF THIS DRAWING FOR
REUSE ON ANOTHER PROJECT IS NOT
AUTHORIZED AND MAY BE CONTRARY TO
THE LAW.
DRAWN BY:
CHECKED BY:
DOCUMENT DATE:
PROTO:
PROTO CYCLE:
DOCUMENTS THAT DO NOT
HAVE THE ARCHITECT OR
ENGINEER OF RECORD SEAL
AND SIGNATURE SHALL BE
CONSIDERED NOT FOR
CONSTRUCTION
SHEET:
ISSUE BLOCK
PROTO:
2022 SUPER BUNDLE
SALEM, MASSACHUSETTS
01/18/22
CS
SL
DIV1
10/29/21
01/18/22
EXTERIOR
SIGNAGE
A2.1
SALEM, MASSACHUSETTS
STORE NO.2640-233
JOB NUMBER: 2021.1165
DIV1
450 HIGHLAND AVE
1/4" = 1'-0"1 5'-6" WALMART SIGN
1/4" = 1'-0"2 2'-6" PICKUP
1/4" = 1'-0"3 2'-0" OUTDOOR
1/4" = 1'-0"4 1'-0" PHARMACY
3/16" = 1'-0"8
TEMPORARY PICKUP BANNER
AT EXISTING LIGHT POLE
3/16" = 1'-0"9 MULTI-TENANT SIGN
1 1/2" = 1'-0"5 SIGN ATTACHMENT AT EIFS ABOVE ROOF LINE
1 1/2" = 1'-0"6 SIGNAGE ATTACHMENT
1/4" = 1'-0"1A 5'-6" WALMART SIGN MOUNTING DIAGRAM
1 1/2" = 1'-0"7
SIGN ATTACHMENT AT EIFS
AND METAL STUD WALL
BCommonwealth of Massachusetts
City of Salem
120 Washington St, 3rd Floor Salem, MA 01970 (978) 745-9595 x5641
Permit No. SP-22-3
FEE PAID: $0.00
DATE ISSUED: February 22, 2022 PERMIT TO BUILD SIGN Expiration Date: August 22, 2022
This certifies
that:
Jennifer Paquin
has permission to erect a
sign(s) on :440 HIGHLAND AVENUE Map/Lot #: 03-0004-0
Detailed as
follows:Sign #1:Wall Sign, , Sign #2: Wall Sign , Sign #3: Wall Sign
Contractor Name: Philadelphia Sign company
DBA:
Installer:
Building Official :
Issued Date: February 22,
2022
This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six months after issuance. The Building Official may grant one or
more extensions not to exceed six months each upon written request.
All work authorized by this permit shall conform to the approved application and the approved construction documents for which this permit has been granted.
All construction, alterations and changes of use of any building and structures shall be in compliance with the local zoning by-laws and codes.
This permit shall be displayed in a location clearly visible from access street or road and shall be maintained open for public inspection for the entire duration of the work until the
completion of the same.
HIC #:
Restrictions:
BBuilding plans are to be available on site.
All Permit Cards are the property of the PROPERTY OWNER.