14 Gallows Hill Road Elevation Plan and Floor PlanTHE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
GENERAL NOTES:
1.THESE DRAWINGS ARE INTENDED TO ILLUSTRATE THE SCOPE OF WORK AND TO FACILITATE CONSTRUCTION. THE
CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND SITE CONDITIONS PRIOR TO THE COMMENCEMENT OF
WORK.
2.ANY DISCREPANCIES BETWEEN THESE DRAWINGS AND ACTUAL FIELD CONDITIONS SHALL BE REPORTED TO THE
DESIGNER BEFORE PROCEEDING WITH THE WORK.
3.ALL CONSTRUCTION SHALL COMPLY WITH THE MASSACHUSETTS STATE BUILDING CODE (780 CMR – 10TH EDITION),
BASED ON THE 2021 INTERNATIONAL RESIDENTIAL CODE (IRC), THE MASSACHUSETTS ENERGY CODE, LOCAL
ZONING REGULATIONS, AND ALL APPLICABLE STATE AND FEDERAL REGULATIONS.
4.THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS AND INSPECTIONS PRIOR TO COMMENCING WORK.
5.ALL WORK SHALL BE PERFORMED BY LICENSED PROFESSIONALS IN ACCORDANCE WITH APPLICABLE CODES AND
REGULATIONS.
6.THE CONTRACTOR SHALL COORDINATE ALL WORK WITH SUBCONTRACTORS AND ENSURE THAT CONSTRUCTION IS
PERFORMED IN A SAFE AND ORDERLY MANNER.
7.EXISTING STRUCTURAL ELEMENTS THAT INTERFERE WITH NEW CONSTRUCTION SHALL BE INSPECTED AND
REINFORCED AS REQUIRED TO MAINTAIN STRUCTURAL INTEGRITY.
8.THE TRANSITION BETWEEN NEW CONSTRUCTION AND EXISTING CONSTRUCTION SHALL BE PROPERLY SEALED
AND WEATHERPROOFED TO PREVENT WATER INFILTRATION.
9.THE CONTRACTOR SHALL PROTECT ALL EXISTING AREAS OF THE RESIDENCE THAT ARE NOT PART OF THE
CONSTRUCTION SCOPE.
10.ANY STRUCTURAL MODIFICATIONS SHALL BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL AND
STRUCTURAL ENGINEER PRIOR TO EXECUTION.
PROJECT ADDRESS:
14 Gallows Hill Rd. - Salem, MA
REMODELING/ ADDITION
PLUMBING, MECHANICAL AND ELECTRICAL (PME) NOTES:
1.ALL PLUMBING, MECHANICAL, AND ELECTRICAL WORK SHALL COMPLY WITH ALL APPLICABLE STATE AND
LOCAL CODES.
2.ALL WORK SHALL BE PERFORMED BY PROPERLY LICENSED TRADESPERSONS IN ACCORDANCE WITH
MASSACHUSETTS REGULATIONS.
3.SUBCONTRACTORS SHALL OBTAIN REQUIRED PERMITS FOR THEIR RESPECTIVE TRADES AND SCHEDULE
ALL REQUIRED INSPECTIONS.
4.STRUCTURAL MEMBERS SHALL NOT BE CUT, DRILLED, OR MODIFIED WITHOUT APPROVAL FROM THE
DESIGN PROFESSIONAL.
5.ALL INSTALLATIONS SHALL FOLLOW MANUFACTURER SPECIFICATIONS AND ACCEPTED CONSTRUCTION
PRACTICES.
6.EQUIPMENT AND SYSTEMS SHALL BE INSTALLED IN A MANNER THAT ALLOWS ACCESS FOR INSPECTION,
MAINTENANCE, AND REPAIR.
STRUCTURAL DESIGN CRITERIA – MASSACHUSETTS (NO GEOTECHNICAL REPORT)
1.NO GEOTECHNICAL (SOIL) INVESTIGATION WAS PERFORMED FOR THIS PROJECT. FOUNDATION DESIGN IS
BASED ON A PRESUMPTIVE ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF IN ACCORDANCE WITH IRC
2021 TABLE R401.4.1.
2.ACTUAL SOIL CONDITIONS SHALL BE VERIFIED ON SITE DURING EXCAVATION BY THE CONTRACTOR AND
THE BUILDING INSPECTOR.
3.IF UNSUITABLE SOIL CONDITIONS, ORGANIC MATERIALS, UNCONTROLLED FILL, OR GROUNDWATER
CONDITIONS ARE ENCOUNTERED, THE ENGINEER AND OWNER SHALL BE NOTIFIED IMMEDIATELY FOR
FURTHER EVALUATION AND POSSIBLE DESIGN REVISIONS.
**** STRUCTURAL NOTES: IT IS THE CONTRACTOR’S AND/OR SUBCONTRACTOR’S
RESPONSIBILITY TO UNDERSTAND THE INTENDED LOAD PATHS AND ENSURE THE PROPER
VERTICAL ALIGNMENT OF ALL LOAD-BEARING COMPONENTS PRIOR TO PERMANENT
INSTALLATION. THE CONTRACTOR/SUBCONTRACTOR SHALL NOTIFY THE DESIGN
PROFESSIONAL IN WRITING OF ANY CHANGES OR VARIATIONS. IF THE ACTUAL SITE
DIMENSIONS VARY MORE THAN 1" TO 2" FROM WHAT HAS BEEN DESIGNED AT ANY
LOCATION, THE CONTRACTOR/SUBCONTRACTOR MUST OBTAIN WRITTEN PERMISSION
FROM THE DESIGN PROFESSIONAL BEFORE EXECUTING THE WORK. ****
FINISH NOTES:
1.RENDERINGS ARE NOT TO SCALE. ALL RENDERINGS ARE FOR
ILLUSTRATIVE PURPOSES ONLY. PLAN UPDATES MAY NOT BE
REFLECTED IN THE RENDERINGS. RENDERINGS SHALL NOT BE USED
FOR CONSTRUCTION.
2.BASEBOARDS SHALL BE 6 INCHES IN HEIGHT IN ALL ROOMS, UNLESS
NOTED OTHERWISE (UNO).
3.FINAL FINISHES SHALL BE CONFIRMED WITH THE HOMEOWNER PRIOR
TO INSTALLATION.
4.THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISTRIBUTING THE
DRAWINGS TO ALL SUBCONTRACTORS UNDER THEIR JURISDICTION.
5.THE CONTRACTOR SHALL COORDINATE THE WORK OF ALL
SUBCONTRACTORS, INCLUDING THE TIMING AND SCHEDULING OF
THEIR WORK AND THE LAYOUT OF THEIR SYSTEMS. THE CONTRACTOR
SHALL PROVIDE ALL SUBCONTRACTORS WITH THE NECESSARY
POWER, ACCESS, AND REQUIRED CONNECTIONS THROUGH
FOUNDATION WALLS AS NEEDED.
6.THE CONTRACTOR ACKNOWLEDGES THAT CONSTRUCTION SITES ARE
INHERENTLY HAZARDOUS ENVIRONMENTS. ALL NECESSARY
PRECAUTIONS SHALL BE TAKEN TO ENSURE THE SAFETY AND
GENERAL WELL-BEING OF WORKERS. THE CONTRACTOR SHALL
PROVIDE GUARDS, RAILS, BARRICADES, FENCES, CATCH PLATFORMS,
BRIDGING, AND OTHER SAFETY MEASURES AS REQUIRED.
7.CONTRACTORS AND SUBCONTRACTORS SHALL FURNISH SAMPLES OF
ALL MATERIALS AND FINISHES SPECIFIED FOR CONSTRUCTION WHEN
REQUESTED BY THE DESIGNER, OWNER, OR GENERAL CONTRACTOR.
LIST OF DRAWINGS:
A-1
PROJECT INFORMATION SHEET
NOTES AND LEGENDS
ILLUSTRATIVE IMAGES
A-2
PROJECT INFORMATION SHEET
NOTES AND LEGENDS
A-3
EXISTING PLANS
A-4
EXISTING PLANS
A-5
EXISTING EXTERIOR ELEVATIONS
A-6
DEMOLITION PLANS
A-7
DEMOLITION PLANS
A-8
PROPOSED PLANS
A-9
PROPOSED PLANS
PROPOSED 3D VIEW
A-10
PROPOSED PLANS
SCHEDULES
A-11
PROPOSED EXTERIOR ELEVATIONS
A-12
PROPOSED FRAME PLANS
A-13
PROPOSED FRAME PLANS
A-14
PROPOSED CROSS SECTIONS
A-15
PROPOSED INTERIOR ELEVATIONS
D -0
DETAILS
PROJECT INFORMATION
SHEET, NOTES AND LEGENDS
SHEET:
SCALE:
DATE:
04/28/2026
A-1
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROJECT SCOPE:
THIS IS A RESIDENTIAL REMODELING AND ADDITION PROJECT LOCATED AT 14
GALLOWS HILL RD., SALEM, MA, DEVELOPED WITH A FOCUS ON MODERNIZING
THE INTERIOR SPACES, EXPANDING THE USABLE AREA, AND ENHANCING THE
COMFORT OF ITS RESIDENTS. THE PROPOSAL INCLUDES THE RECONFIGURATION
OF THE EXISTING INTERIOR LAYOUT, INCLUDING THE REMODELING OF THE
KITCHEN, LIVING ROOM, AND BATHROOMS, AS WELL AS THE EXPANSION OF THE
DECK, INCORPORATING NEW SUPPORT SPACES SUCH AS A LAUNDRY ROOM,
STORAGE AREAS, AND MULTIFUNCTIONAL ROOMS. THE PROJECT ALSO PROVIDES
FOR THE CREATION OF NEW SUITES, ADDITIONAL BEDROOMS, AN OFFICE, A
WALK-IN CLOSET, AND A MASTER SUITE WITH A PRIVATE BATHROOM,
DISTRIBUTED ACROSS NEW LEVELS, INCLUDING A SECOND FLOOR AND A
FINISHED ATTIC SPACE. EXTERNALLY, THE RESIDENCE RECEIVES NEW
ELEVATIONS, VOLUMETRIC EXPANSION WITH DORMERS ON THE ROOF, AND
STRUCTURAL AS WELL AS ARCHITECTURAL ADJUSTMENTS, PROMOTING A
CONTEMPORARY DESIGN LANGUAGE WHILE MAINTAINING INTEGRATION WITH
THE EXISTING CONSTRUCTION. THE ENTIRE INTERVENTION WAS DESIGNED IN
COMPLIANCE WITH THE MASSACHUSETTS STATE BUILDING CODE AND IRC 2021,
PRIORITIZING FUNCTIONALITY, STRUCTURAL SAFETY, THERMAL COMFORT, AND
OPTIMIZED USE OF SPACE.
NO SCALE
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-2
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROJECT INFORMATION
SHEET, NOTES AND LEGENDS
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
a. Spans are given in feet and inches.
b. Spans are based on minimum design properties for No. 2 grade lumber of Douglas fir-larch, hem-fir, Southern pine, and
spruce-pine-fir.
c. Building width is measured perpendicular to the ridge. For widths between those shown, spans are permitted to be
interpolated.
d. NJ = Number of jack studs required to support each end. Where the number of required jack studs equals one, the header is
permitted to be supported by an approved framing anchor attached to the full-height wall stud and to the header.
e. Spans are calculated assuming the top of the header or girder is laterally braced by perpendicular framing. Where the top of
the header or girder is not laterally braced (for example, cripple studs bearing on the header), tabulated spans for headers
consisting of 2 × 8, 2 × 10, or 2 × 12 sizes shall be multiplied by 0.70 or the header or girder shall be designed.
SEE R301.2(1) TABLE FOR FOOT NOTES
GROUND
SNOW LOAD
WIND
SPEED
TABLE
R301.2(2)
55 PSF
TABLE
R301.2(2)
110 MPH
SEISMIC
DESIGN
N/A
N/A
WEATHER!
NG
FROST
LINE
TERMITE DECAY WINTER
DESIGN
TEMP
FIGURE
5301.2(3)
48 INCHES.
FOR FROST
PROTECTED
SHALLOW
FOUNDATIO
NS, SEE
R403.3.
SEVERE 48 inches (4 ft)
FIGURE
5301.2(6)
MODERATE
TO HEAVY
FIGURE
5301.2(7)
SLIGHT TO
MODERATE
APPENDIX
780 CMR
120.J TABLE
120.J.3.2.1
10ºF
ICE SHIELD
UNDERLAYMENT
REQUIRED
AS REQUIRED BY
THE EXTERIOR
ROOF
COVERING
MANUFACTURER
ROOF PITCH AND
LOCAL CLIMATE
MUST
ALSO BE
CONSIDERED
R905.1.2
FLOOD
HAZARD
REFER TO
APPLICABLE
FLOOD
INSURANCE
RATE MAP
(FIRM)
REFER TO
FEMA FIRM
AIR FREEZING
INDEX
ONLY UTILIZED
IN THE DESIGN
AND
CONST. OF
FROST
PROTECTED
SHALLOW
FOUNDATION
SEE NOTE J
TABLE 5301.2(1)
MEAN ANNUAL
TEMP
ONLY UTILIZED
IN DESIGN AND
CONST. OF
FROST
PROTECTED
SHALLOW
FOUNDATIONS
SEE NOTE K
TABLE 5301.2(1)
TABLE R301.7
ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa.b.c.d,e
ALLOWABLE STRUCT. MEMBER DEFLECTION
RAFTERS HAVING SLOPES GREATER THAN
3: 12 WITH NOFINISHED CEILING ATTACHED TO RAFTERS L/180
INTERIOR WALLS AND PARTITIONS H/180
FLOORS AND PLASTERED CEILINGS L/360
ALL OTHER STRUCTURAL MEMBERS L/240
EXTERIOR WALLS WITH OLASTER OR STUCCO FINISH H/360
EXTERIOR WALLS-WIND LOAD SITH BRITTLE FINISHES H/240
EXTERIOR WALLS-WIND LOADS WITH FLEXIBLE FINISHES L/120
LINTELS SUPPORTING MASONRY VENEER WALLS L/600
Note:
L = span length, H = span height.
A.THE WIND LOAD SHALL BE PERMITTED TO BE TAKEN AS 0.7 TIMES THE COMPONENT AND
CLADDING LOADS FOR THE PURPOSEOF THE DETERMINING DEFLECTION LIMITS HEREIN.
B.FOR CANTILEVER MEMBERS, L SHALL BE TAKEN AS TWICE THE LENGTH OFTHE CANTILEVER.
C.FOR ALUMINUM STRUCTURAL MEMBERS OR PANELS USED IN ROOFS OR WALLS OF SUNROOM
ADDITIONS OR PATIO COVERS, NOT SUPPORTING EDGE OF GLASS OR SANDWICH PANELS,
THE TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/60. FOR CONTINUOUS ALUMINUM
STRUCTURAL MEMBERS SUPPORTING EDGEOF GLASS, THE TOTAL LOAD DEFLECTION SHALL
NOT EXCEED L/175 FOR EACH GLASS LITE OR L/60 FOR THE ENTIRE LENGTH OF THE MEMBER,
WHICHEVER IS MORE STRINGENT. FOR SANDWICH PANELS USED IN ROOFS OR WALLS
OFSUNROOM ADDITIONS OR PATIO COVERS, THE TOTAL LOAD DEFLECTION SHALL
NOTEXCEED L/120.
D.DEFLECTION FOR EXTERIOR WALLS WITH INTERIOR GYPSUM BOARD FINISH SHALL BE
LIMITED TO AN ALLOWABLE DEFLECTION OF H/180.E. REFER TO SECTION R703.7.2.
TABLE R301.5
MINIMUM UNIFORMLY
DISTRIBUTED LIVE LOADS
(in pounds per square foot)
USE LIVE LOAD
Attics w/o storage'b 10 Fire escapes 40
Attics with limited storage"b,g 20 Guardrails and handrails'd 200
Habitable attics and attics served 30 Rooms other than sleeping room 40
with fixed stairs Sleeping rooms 30
Balconies (exterior) 40
and decks'e Stairs 40
TABLE R402.1.1 INSULATION AND FENESTRATION
REQUIREMENTS BY COMPONENT
CLIMATE ZONE 5
SKYLIGHT(b) U-FACTOR .30
GLAZED FENESTRATION U-FACTOR .55
GLAZED FENESTRATION SHGC NR
CEILING R-VALUE 49
WOOD FRAME WALL R-VALUE 20 or 13+5(h)
MASS WALL R-VALUE(k) 13/17
FLOOR R-VALUE 30(g)
BASEMENT WALL(c) FLOOR 15/19
BASEMENT SLAB(d) AND DEPTH R-VALUE 10,2 FT
CRAWL WALL SPACE (c) R-VALUE 15/19
FOR SI: 1 FOOT = 304.8 MM.
a.R-VALUES ARE MINIMUMS. U-FACTORS AND SHGC ARE MAXIMUMS. WHEN
INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR
DESIGN THICKNESS OF THE INSULATION, THE INSTALLED R-VALUE OF THE
INSULATION SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE.
b.THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS. THE SHGC
COLUMN APPLIES TO ALL GLAZED FENESTRATION. EXCEPTION: SKYLIGHTS MAY
BE EXCLUDED FROM GLAZED FENESTRATION SHGC REQUIREMENTS IN CLIMATE
ZONES 1 THROUGH 3
WHERE THE SHGC FOR SUCH SKYLIGHTS DOES NOT EXCEED 0.30.
c."15/19 MEANS R-15 CONTINUOUS INSULATION ON THE INTERIOROR EXTERIOR OF
THE HOME OR R-19 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL.
"15/19"
SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR
OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR
EXTERIOR OF THE HOME. "10/13" MEANS R-10 CONTINUOUS INSULATION ON THE
INTERIOR OR EXTERIOR OF THE HOME OR R-13 CAVITY INSULATION AT THE
INTERIOR OF THE BASEMENT WALL.
d.R-5 SHALL BE ADDED TO THE REQUIRED SLAB EDGER-VALUES FOR HEATED
SLABS.
INSULATION DEPTH SHALL BE THE DEPTH OF THE FOOTING OR 2 FEET, WHICHEVER
IS LESS IN CLIMATE ZONES 1 THROUGH 3 FOR HEATED SLABS.
e. THERE ARE NO SHGC REQUIREMENTS IN THE MARINE ZONE.
f. BASEMENT WALL INSULATION IS NOT REQUIRED IN WARM-HUMID LOCATIONS AS
DEFINED BY FIGURE R301.1 AND TABLE R301.1.
9. OR INSULATION SUFFICIENT TO FILL THE FRAMING CAVITY, R-19 MINIMUM.
h. FIRST VALUE IS CAVITY INSULATION, SECOND IS CONTINUOUS INSULATION OR
INSULATED
SIDING, SO "13+5" MEANS R-13 CAVITY INSULATION PLUS R-5 CONTINUOUS
INSULATION OR INSULATED SIDING. IF STRUCTURAL SHEATHING COVERS 40
PERCENT OR LESS OF THE EXTERIOR, CONTINUOUS INSULATION R-VALUE SHALL
BE PERMITTED TO BE REDUCED BY NO MORE THAN R-3 IN THE LOCATIONS WHERE
STRUCTURAL SHEATHING IS USED- TO MAINTAIN A CONSISTENT TOTAL SHEATHING
THICKNESS. i.THE SECOND -VALUE APPLIES WHEN MORE THAN HALF THE
INSULATION IS ON THE INTERIOR OF THE MASS WALL
Check sources for availability of lumber in lengths greater than 20 feet.
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa.
a. Span exceeds 26 feet in length.
ARCHITECTURAL:
A1. PROVIDE A MINIMUM 4-MIL POLYETHYLENE VAPOR RETARDER OVER INSULATION ON THE INTERIOR
(WARM SIDE) OF ALL EXTERIOR WALLS AND ROOF/CEILING ASSEMBLIES IN ACCORDANCE WITH IRC 2021
SECTION R702.7.
A2. EXTERIOR WALLS SHALL PROVIDE A WEATHER-RESISTIVE EXTERIOR WALL ENVELOPE. PROVIDE
WEATHER-RESISTIVE BARRIER AND FLASHING DETAILS FOR WINDOWS, DOORS, AND OTHER OPENINGS
IN THE BUILDING ENVELOPE. INSTALLATION SHALL COMPLY WITH MANUFACTURER SPECIFICATIONS.
PROVIDE FLASHING AT DOORS, WINDOWS, SILLS, FOUNDATIONS, COLUMNS, AND OTHER LOCATIONS
REQUIRING MOISTURE PROTECTION IN ACCORDANCE WITH IRC 2021 SECTION R703.1.
A3. INSPECTIONS ARE REQUIRED FOR ALL STUCCO AND EIFS SYSTEMS. PROVIDE PRODUCT
SPECIFICATIONS AND EVALUATION REPORTS FOR ANY STUCCO OR EIFS SYSTEM USED IN ACCORDANCE
WITH IRC 2021 SECTIONS R703.7 AND R703.9.
A4. WINDOW SILLS LOCATED MORE THAN 6 FEET ABOVE GRADE AND LESS THAN 24 INCHES ABOVE THE
INTERIOR FLOOR SHALL COMPLY WITH FALL PROTECTION REQUIREMENTS. THE PORTION OF THE
WINDOW OPENING BELOW 24 INCHES ABOVE THE FLOOR SHALL BE FIXED OR PROTECTED BY A GUARD
THAT PREVENTS THE PASSAGE OF A 4-INCH DIAMETER SPHERE IN ACCORDANCE WITH IRC 2021 SECTION
R312.2.
A5. A PERMANENT CERTIFICATE SHALL BE POSTED ON OR NEAR THE ELECTRICAL DISTRIBUTION PANEL
LISTING INSULATION R-VALUES FOR CEILINGS/ROOFS, WALLS, FOUNDATIONS (SLABS, BASEMENT WALLS,
CRAWLSPACE WALLS, AND FLOORS), AND DUCTS LOCATED OUTSIDE CONDITIONED SPACES. THE U-
FACTOR OF WINDOWS AND THE SOLAR HEAT GAIN COEFFICIENT (SHGC) OF FENESTRATION SHALL ALSO
BE LISTED, ALONG WITH THE TYPE AND EFFICIENCY OF HEATING, COOLING, AND SERVICE WATER
HEATING EQUIPMENT IN ACCORDANCE WITH IRC 2021 SECTION N1101.9.
A6. STAIR RISER HEIGHT SHALL NOT EXCEED 8-1/4 INCHES (196 MM). RISERS SHALL BE MEASURED
VERTICALLY BETWEEN THE LEADING EDGES OF ADJACENT TREADS. OPEN RISERS ARE PERMITTED
PROVIDED THE OPENING DOES NOT ALLOW PASSAGE OF A 4-INCH DIAMETER SPHERE IN ACCORDANCE
WITH IRC 2021 SECTION R311.7.5.1 AND MASSACHUSETTS AMENDMENTS.
A7. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY
MORE THAN 3/8 INCH (9.5 MM) IN ACCORDANCE WITH IRC 2021 SECTION R311.7.5.1.
A8. STAIR TREAD DEPTH SHALL BE A MINIMUM OF 9 INCHES (254 MM), MEASURED HORIZONTALLY
BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A
RIGHT ANGLE TO THE TREAD’S LEADING EDGE IN ACCORDANCE WITH IRC 2021 SECTION R311.7.5.2.
A9. STAIR TREAD NOSING SHALL HAVE A RADIUS OF CURVATURE AT THE LEADING EDGE NOT EXCEEDING
9/16 INCH. A NOSING PROJECTION BETWEEN 3/4 INCH AND 1-1/4 INCHES SHALL BE PROVIDED ON
STAIRWAYS WITH SOLID RISERS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE
SMALLEST BY MORE THAN 3/8 INCH. BEVELING OF THE NOSING SHALL NOT EXCEED 1/2 INCH. RISERS
SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE TREAD ABOVE AT AN ANGLE NOT
GREATER THAN 30 DEGREES FROM VERTICAL. OPEN RISERS SHALL NOT ALLOW PASSAGE OF A 4-INCH
DIAMETER SPHERE IN ACCORDANCE WITH IRC 2021 SECTION R311.7.5.3.
STRUCTURAL:
S1. PROVIDE DOUBLE JOISTS UNDER BEARING PARTITIONS WHICH ARE PARALLEL TO FLOOR JOISTS. IRC
2021 SECTION R502.4.
S2. PROVIDE SOLID BLOCKING AT BEARING POINTS ON FLOOR JOISTS OR RAFTERS. IRC 2021 SECTION
R502.7.
S3. PROVIDE TONGUE-AND-GROOVE (T&G) UNDERLAYMENT-GRADE PLYWOOD SUBFLOOR WITH
APPROPRIATE NAILING SCHEDULE WHERE NO ADDITIONAL PARTICLEBOARD UNDERLAYMENT IS
PROVIDED. IRC 2021 SECTION R503.2.
S4. EXTERIOR WALLS EXCEEDING 10'-0" IN HEIGHT SHALL BE VERIFIED FOR THEIR ABILITY TO RESIST
REQUIRED WIND LOADS COMBINED WITH AXIAL LOADS. IBC SECTION 2306.
S5. FIREBLOCK STUD SPACES AT SOFFITS, FLOOR AND CEILING JOIST LINES, AT 10 FEET VERTICALLY
AND HORIZONTALLY, AND AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY SPACES FOR FACTORY-
BUILT CHIMNEYS, AND AT ANY OTHER LOCATIONS WHICH COULD ALLOW THE PASSAGE OF FLAMES. IRC
2021 SECTION R302.11.
S6. PROVIDE HURRICANE TIES AT ALL RAFTERS AND TRUSSES. IRC 2021 SECTION R802.11.1.
S7. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT NO STRUCTURAL BEARING WALLS ARE
REMOVED WITHOUT INSPECTION BY THE DESIGN ENGINEER AND BUILDING INSPECTOR. ANY EXISTING
STRUCTURAL ELEMENTS INTENDED TO REMAIN SHALL BE VERIFIED TO BE IN GOOD CONDITION. IF
DEFICIENT, THEY SHALL BE REPLACED.
ALLOWABLE JOIST SPANS
R502.3. FLOOR JOIST SPANS SHALL COMPLY WITH 780 CMR TABLES 5502.3.1(1) AND 5502.3.1(2). FOR
OTHER GRADES, SPECIES, OR LOADING CONDITIONS, REFER TO AF&PA SPAN TABLES FOR JOISTS AND
RAFTERS OR THE AF&PA MAXIMUM SPAN CALCULATOR.
CEILING JOIST AND RAFTER CONNECTIONS
R802.3.1. WHERE CEILING JOISTS ARE NOT CONNECTED TO RAFTERS AT THE TOP WALL PLATE, JOISTS
INSTALLED HIGHER IN THE ATTIC SHALL BE INSTALLED AS RAFTER TIES, OR RAFTER TIES SHALL BE
PROVIDED TO CREATE A CONTINUOUS TIE.
WHERE CEILING JOISTS ARE NOT PARALLEL TO RAFTERS, RAFTER TIES SHALL BE INSTALLED.
RAFTER TIES SHALL BE NOT LESS THAN 2 INCHES BY 4 INCHES (NOMINAL) AND SHALL BE INSTALLED IN
ACCORDANCE WITH TABLE R802.5.1(9), OR CONNECTIONS OF EQUIVALENT CAPACITY SHALL BE
PROVIDED.
WHERE CEILING JOISTS OR RAFTER TIES ARE NOT PROVIDED, THE RIDGE FORMED BY THESE RAFTERS
SHALL BE SUPPORTED BY A WALL OR GIRDER DESIGNED IN ACCORDANCE WITH ACCEPTED
ENGINEERING PRACTICE.
5'-5"5'-4 1/2"5'-4"
16'-8"
16'-5"8'-4"
16'-11 1/2"
31'-4"
22'-4"
23'-9 1/2"
24'-6 1/2"
8'-10 1/2"
12'-1"
22'-4"
20'-11 1/2"
30'
21'-1 1/2"
21'-10 1/2"
11'-5" X 21'-0"
30'-0" X 21'-10"
EXISTING DROPPED BEAM
EXISTING FAMILY
ROOM ABOVE
EXISTING DECK
ABOVE
EXISTING STAIR TO
DECK ABOVE
EXISTING POST WITH
SONOTUBE
EXISTING POST WITH
SONOTUBE
EXISTING POST WITH
SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
GARAGE
EXISTING FOUNDATION
ASSUMED EXISTING FOUNDATION WALL – VERIFY IN FIELD
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
DOORWAY
EXISTING
BUILT-IN CABINET
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
UP
12'-9"
14'-11 1/2"
16'-2"
20'-9"
3'-8"4'-10"
6'-1"
9'-7"
6'-5 1/2"
3'-2"
31'-5 1/2"
10'-9"
8'-9"
11'-4"
21'
4'-11"
3'-5"
4'-4 1/2"
1'-10"
7"
5'-2"
3'-5"
4'-7"
10'-6"
5'-5"5'-4 1/2"5'-4"
16'-8"
16'-5"8'-4"
16'-11 1/2"
21'-4" X 4'-7"
EXISTING OPEN
MECHANICAL AREA
LOW CEILING
CLOSET
EXISTING COUNTER
EXISTING
FIREPLACE
EXISTING DROPPED BEAMASSUMED BEARING WALL – VERIFY IN FIELD
GARAGE LEVEL
0' - 4"
EXISTING WALL-MOUNTED SHELVES
EXISTING DROPPED BEAM
EXISTING FAMILY
ROOM ABOVE
EXISTING DECK
ABOVE
EXISTING STAIR TO
DECK ABOVE
EXISTING POST WITH
SONOTUBE
EXISTING POST WITH
SONOTUBE
EXISTING POST WITH
SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
EXISTING COLUMN LALLY
WITH SONOTUBE
PORCH
9'-7"
EXISTING POST EXISTING POST
WALL SCHEDULE
2D SYMBOL WALL TYPE
16" CONCRETE STEM WALL
EXISTING CONCRETE WALL
EXISTING EXTERIOR BRICK WALL
EXISTING EXTERIOR WALL
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL - 6
EXISTING INTERIOR WALL - 8
INTERIOR RAILING
ROOM DIVIDER
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-3
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
EXISTING PLANS
EXISTING GROUND PLAN
SCALE: 1/4" = 1'-0"
EXISTING FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
***NOTE – EXISTING FOUNDATION CONDITIONS:
EXISTING FOUNDATION WALLS AND BEARING CONDITIONS ARE BASED ON LIMITED OBSERVATION AND
SHALL BE VERIFIED IN FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
ANY DISCREPANCIES SHALL BE REPORTED TO THE DESIGN PROFESSIONAL. NO WORK SHALL PROCEED
IN AFFECTED AREAS UNTIL DIRECTION IS PROVIDED.
DN
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOORWAY
EXISTING
PASS-THOROUGH
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
DOOR
DN
9'-10"
12'-11"
9'-5"
8'-8"
3'-1 1/2"
11'-2"
9'-11"
13'-3"7'-5"
11'-6"
15'-3"
16'-1"
9'-11"
23'-4 1/2"
12'-11"
9'-11 1/2"
7'-10"
11'-5 1/2"
5'-8"
10'-1"
5'
5'
5'-1"
31'-5 1/2"
15'-3" X 23'-5"
13'-3" X 9'-11"
7'-5" X 9'-11"
2'-4" X 4'-6"
1'-4" X 4'-6"
7'-5" X 7'-11"
8'-8" X 9'-5"
15'-3" X 16'-1"
9'-10" X 12'-11"
1'-4" X 4'-6"
11'-2" X 3'-2"
3'-9" X 1'-1"
1'-7" X 3'-11"
11'-6" X 9'-11"
8'-4" X 17'-0"
LIVING
CLOSET
BEDROOM
CLOSET
FAMILY ROOM
CLOSET
BEDROOM
STAIRWELL
HALL
PRIMARY
BEDROOM
CLOSET
CLOSET
KITCHEN
BATH
EXISTING
FIREPLACE
EXISTING DROPPED BEAM
EXISTING DROPPED BEAM
EXISTING BAY WINDOW
DECK
EXISTING STAIR TO
DECK ABOVE
EXISTING
AWNING
EXISTING
AWNING
ASSUMED BEARING WALL – VERIFY IN FIELDVERIFY IN FIELD IF A FLUSH BEAM EXISTS
IN THIS AREA UPON CEILING OPENING
CHIMNEY USE AND CONDITION
SHALL BE VERIFIED IN FIELD.
ANY UNUSED OR ABANDONED
FLUES SHALL BE PROPERLY
CAPPED AND SEALED.
3 : 12 3 : 12
4 : 12
4 : 12
3 : 12
9'-7"9'-7"
28'-4 1/2"
13'-8"
13'-8"
47'-7 1/2"
10'-2"
14'-4"
17'-2"
17'
1'-6"
2'-4 1/2"
1'-6"
EXISTING ROOF
EXISTING ROOF
EXISTING ROOFEXISTING ROOF
EXISTING LOWER ROOF
WALL SCHEDULE
2D SYMBOL WALL TYPE
16" CONCRETE STEM WALL
EXISTING CONCRETE WALL
EXISTING EXTERIOR BRICK WALL
EXISTING EXTERIOR WALL
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL - 6
EXISTING INTERIOR WALL - 8
INTERIOR RAILING
ROOM DIVIDER
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-4
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
EXISTING PLANS
3D VIEW
EXISTING FIRST FLOOR PLAN
SCALE: 1/4" = 1'-0"
EXISTING ROOF PLAN
SCALE: 1/4" = 1'-0"
EXISTING 3D VIEW
SCALE: NO SCALE
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
DOOR
EXISTING
BAY WINDOW
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
EXISTING ROOF LEVEL
20' - 10"
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
DOOR
EXISTING
VENT
EXISTING
DOOR
EXISTING
DOOR
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
EXISTING ROOF LEVEL
20' - 10"
EXISTING
VENT
EXISTING
DOOR
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOWEXISTING
WINDOWEXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
EXISTING ROOF LEVEL
20' - 10"
EXISTING
WINDOW
EXISTING
WINDOWEXISTING
WINDOWEXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOWEXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
VENT
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
EXISTING ROOF LEVEL
20' - 10"
EXISTING
WINDOW
EXISTING
WINDOWEXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
VENT
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-5
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
EXISTING EXTERIOR
ELEVATIONS
EXISTING ELEVATION - FRONT
SCALE: 1/4" = 1'-0"
EXISTING ELEVATION - LEFT
SCALE: 1/4" = 1'-0"
EXISTING ELEVATION - BACK
SCALE: 1/4" = 1'-0"
EXISTING ELEVATION - RIGHT
SCALE: 1/4" = 1'-0"
5'-5"5'-4 1/2"5'-4"
16'-8"
16'-5"8'-4"
16'-11 1/2"
31'-4"
22'-4"
23'-9 1/2"
24'-6 1/2"
8'-10 1/2"
12'-1"
22'-4"
20'-11 1/2"
21'-10 1/2"
21'-1 1/2"
11'-5" X 21'-0"
30'-0" X 21'-10"
DEMOLITION DROPPED BEAM
DEMOLITION FAMILY
ROOM ABOVE
DEMOLITION DECK
ABOVE
DEMOLITION STAIR
TO DECK ABOVE
DEMOLITION POST
WITH SONOTUBE
DEMOLITION POST
WITH SONOTUBE
DEMOLITION POST
WITH SONOTUBE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
GARAGE
EXISTING FOUNDATION
ASSUMED EXISTING FOUNDATION WALL – VERIFY IN FIELD
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
DEMOLITION
DOOR
EXISTING
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
EXISTING
DOORWAY
EXISTING
BUILT-IN CABINET
UP
12'-9"
14'-11 1/2"
16'-2"
20'-9"
3'-8"4'-10"
6'-1"
9'-7"
6'-5 1/2"
3'-2"
31'-5 1/2"
10'-9"
8'-9"
11'-4"
21'
4'-11"
3'-5"
4'-4 1/2"
1'-10"
7"
5'-2"
3'-5"
4'-7"
10'-6"
8'-4"
16'-11 1/2"
5'-5"5'-4 1/2"5'-4"
16'-9"
16'-5"
21'-4" X 4'-7"
EXISTING OPEN
MECHANICAL AREA
DEMOLITION
CLOSET
EXISTING COUNTER
EXISTING
FIREPLACE
EXISTING DROPPED BEAMASSUMED BEARING WALL – VERIFY IN FIELD
GARAGE LEVEL
0' - 4"
EXISTING WALL-MOUNTED SHELVES
PORCH
DEMOLITION DECK
ABOVE
DEMOLITION STAIR
TO DECK ABOVE
DEMOLITION POST
WITH SONOTUBE
DEMOLITION POST
WITH SONOTUBE
DEMOLITION POST
WITH SONOTUBE
DEMOLITION DROPPED BEAM
DEMOLITION FAMILY
ROOM ABOVE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
DEMOLITION COLUMN
LALLY WITH SONOTUBE
ASSUMED BEARING WALL – VERIFY IN FIELD
EXISTING WALL TO REMAIN – MODIFY AS
REQUIRED TO SUPPORT NEW CONSTRUCTION
9'-7"
EXISTING POST EXISTING POST
WALL SCHEDULE
2D SYMBOL WALL TYPE
16" CONCRETE STEM WALL
DEMOLITION EXTERIOR WALL
DEMOLITION INTERIOR WALL
EXISTING CONCRETE WALL
EXISTING EXTERIOR BRICK WALL
EXISTING EXTERIOR WALL
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL - 6
DEMOLITION INTERIOR WALL - 8
INTERIOR RAILING
ROOM DIVIDER
EXISTING INTERIOR WALL - 8
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-6
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
DEMOLITION PLANS
DEMOLITION GROUND PLAN
SCALE: 1/4" = 1'-0"
DEMOLITION FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
**NOTE - DEMOLITION / SELECTIVE REMOVAL: EXISTING FOUNDATION- WHERE INDICATED, EXISTING
FOUNDATION ELEMENTS, BEARING POINTS, AND ANY NONCOMPLIANT OR INADEQUATE SUPPORT CONDITIONS
SHALL BE SELECTIVELY REMOVED, MODIFIED, OR ABANDONED AS REQUIRED TO ACCOMMODATE THE
PROPOSED CONSTRUCTION.- ANY EXISTING FOUNDATION COMPONENTS FOUND TO BE DISCONTINUOUS,
UNSTABLE, IMPROPERLY BEARING, OR OTHERWISE UNSUITABLE FOR CONTINUED STRUCTURAL SUPPORT
SHALL NOT BE RELIED UPON AND SHALL BE REMOVED OR SUPPLEMENTED AS REQUIRED.- CONTRACTOR
SHALL PROVIDE TEMPORARY SHORING AND SUPPORT OF THE STRUCTURE DURING ALL DEMOLITION AND
FOUNDATION WORK OPERATIONS.- IF UNFORESEEN CONDITIONS ARE ENCOUNTERED, INCLUDING BUT NOT
LIMITED TO UNDOCUMENTED FOUNDATION ELEMENTS, VOIDS, OR UNSUITABLE BEARING MATERIALS,
CONTRACTOR SHALL STOP WORK IN THE AFFECTED AREA AND NOTIFY THE DESIGN PROFESSIONAL PRIOR TO
PROCEEDING.
***NOTE– DEMOLITION / SELECTIVE REMOVAL NOTE – EXISTING EXTERIOR WALLS- WHERE INDICATED, EXISTING
WALL FINISHES, DETERIORATED WOOD COMPONENTS, NONCOMPLIANT MATERIALS, AND ANY OTHER UNSOUND
PORTIONS OF THE EXISTING EXTERIOR WALL ASSEMBLY SHALL BE SELECTIVELY REMOVED AS REQUIRED TO
ALLOW FOR PROPER REPAIR AND INTEGRATION WITH THE PROPOSED CONSTRUCTION.- ANY WOOD MEMBERS
FOUND TO BE ROTTED, SPLIT, LOOSE, MOISTURE-DAMAGED, OR OTHERWISE UNSUITABLE FOR CONTINUED
SERVICE SHALL BE REMOVED AND REPLACED.- CONTRACTOR SHALL PROTECT ALL PORTIONS INTENDED TO
REMAIN AND SHALL MAINTAIN TEMPORARY BRACING AND WEATHER PROTECTION AS REQUIRED DURING
DEMOLITION AND REPAIR OPERATIONS.- IF CONCEALED STRUCTURAL DEFICIENCIES ARE ENCOUNTERED,
CONTRACTOR SHALL STOP WORK IN AFFECTED AREA AND NOTIFY THE DESIGN PROFESSIONAL PRIOR TO
PROCEEDING.
NOTE: THIS PROJECT INVOLVES THE RESTRUCTURING OF THE EXISTING RESIDENCE, INCLUDING
MODIFICATIONS AND PARTIAL DEMOLITION OF BUILDING AND STRUCTURAL ELEMENTS AS INDICATED IN THE
DRAWINGS. EXISTING STRUCTURAL COMPONENTS — INCLUDING FLOOR SLABS, BEAMS, COLUMNS,
FOUNDATIONS, AND BEARING WALLS — MAY BE ALTERED, REMOVED, OR REINFORCED IN AREAS AFFECTED BY
THE WORK. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY TEMPORARY SHORING,
BRACING, AND SUPPORTS TO MAINTAIN STRUCTURAL STABILITY DURING ALL DEMOLITION AND CONSTRUCTION
OPERATIONS. ALL NEW LOADS SHALL BE PROPERLY TRANSFERRED AND DISTRIBUTED IN ACCORDANCE WITH
THE STRUCTURAL CALCULATIONS AND IN COMPLIANCE WITH APPLICABLE CODES.
NOTE: THIS PROJECT INVOLVES THE RESTRUCTURING OF THE EXISTING RESIDENCE, INCLUDING
MODIFICATIONS AND PARTIAL DEMOLITION OF BUILDING AND STRUCTURAL ELEMENTS AS INDICATED IN THE
DRAWINGS. EXISTING STRUCTURAL COMPONENTS — INCLUDING FLOOR SLABS, BEAMS, COLUMNS,
FOUNDATIONS, AND BEARING WALLS — MAY BE ALTERED, REMOVED, OR REINFORCED IN AREAS AFFECTED BY
THE WORK. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY TEMPORARY SHORING,
BRACING, AND SUPPORTS TO MAINTAIN STRUCTURAL STABILITY DURING ALL DEMOLITION AND CONSTRUCTION
OPERATIONS. ALL NEW LOADS SHALL BE PROPERLY TRANSFERRED AND DISTRIBUTED IN ACCORDANCE WITH
THE STRUCTURAL CALCULATIONS AND IN COMPLIANCE WITH APPLICABLE CODES.
DN
EXISTING
DOOR
DEMOLITION
WINDOW
DEMOLITION
WINDOW
EXISTING
WINDOW
DEMOLITION
DOOR
DEMOLITION
DOOR
DEMOLITION
DOORWAY
DEMOLITION
PASS-THOROUGH
EXISTING
WINDOW
DEMOLITION
WINDOW
EXISTING
WINDOW
DEMOLITION
WINDOW
DEMOLITION
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
DEMOLITION
WINDOW
DEMOLITION
WINDOW
DEMOLITION
WINDOW
EXISTING
DOOR
DEMOLITION
DOOR
DEMOLITION
DOOR
DN
9'-10"
12'-11"
9'-5"
8'-8"
3'-1 1/2"
11'-2"
9'-11"
13'-3"7'-5"
11'-6"
15'-3"
16'-1"
9'-11"
23'-4 1/2"
12'-11"
9'-11 1/2"
7'-10"
11'-5 1/2"
5'-8"
10'-1"
5'
5'
5'-1"
15'-3" X 23'-5"
13'-3" X 9'-11"
9'-10" X 12'-11"
7'-5" X 9'-11"
2'-4" X 4'-6"
1'-4" X 4'-6"
7'-5" X 7'-11"
8'-8" X 9'-5"
15'-3" X 16'-1"
1'-4" X 4'-6"
11'-2" X 3'-2"
3'-9" X 1'-1"
1'-7" X 3'-11"
11'-6" X 9'-11"
8'-4" X 17'-0"
LIVING
CLOSET
BEDROOM
CLOSET
FAMILY ROOM
CLOSET
BEDROOM
STAIRWELL
HALL
PRIMARY
BEDROOM
CLOSET
CLOSET
KITCHEN
BATH
EXISTING
FIREPLACE
DEMOLITION DROPPED BEAM
DEMOLITION DROPPED BEAM
DEMOLITION BAY WINDOW
DEMOLITION DECK
DEMOLITION STAIR
TO DECK ABOVE
DEMOLITIO
N AWNING
DEMOLITIO
N AWNING
ASSUMED BEARING WALL – VERIFY IN FIELD
DEMOLITION FLUSH BEAM
EXISTING WALL TO REMAIN – MODIFY AS REQUIRED TO SUPPORT NEW CONSTRUCTION
DEMOLITION OF EXTERIOR WALL TO
CREATE DOOR OPENING
DEMOLITION OF
EXTERIOR WALL TO
CREATE WINDOW
OPENING
DEMOLITION OF
EXTERIOR WALL TO
CREATE WINDOW
OPENING
3 : 12 3 : 12
4 : 12
4 : 12
3 : 12
9'-7"9'-7"
28'-4 1/2"
13'-8"
13'-8"
47'-7 1/2"
10'-2"
14'-4"
17'-2"
17'
1'-6"
2'-4 1/2"
1'-6"
DEMOLITION ROOF
DEMOLITION ROOF
DEMOLITION ROOFDEMOLITION ROOF
EXISTING LOWER ROOF
WALL SCHEDULE
2D SYMBOL WALL TYPE
16" CONCRETE STEM WALL
DEMOLITION EXTERIOR WALL
DEMOLITION INTERIOR WALL
EXISTING CONCRETE WALL
EXISTING EXTERIOR BRICK WALL
EXISTING EXTERIOR WALL
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL - 6
DEMOLITION INTERIOR WALL - 8
INTERIOR RAILING
ROOM DIVIDER
EXISTING INTERIOR WALL - 8
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-7
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
DEMOLITION FIRST FLOOR PLAN
SCALE: 1/4" = 1'-0"
DEMOLITION ROOF PLAN
SCALE: 1/4" = 1'-0"
DEMOLITION PLANS
NOTE: THIS PROJECT INVOLVES THE RESTRUCTURING OF THE EXISTING RESIDENCE, INCLUDING
MODIFICATIONS AND PARTIAL DEMOLITION OF BUILDING AND STRUCTURAL ELEMENTS AS INDICATED IN THE
DRAWINGS. EXISTING STRUCTURAL COMPONENTS — INCLUDING FLOOR SLABS, BEAMS, COLUMNS,
FOUNDATIONS, AND BEARING WALLS — MAY BE ALTERED, REMOVED, OR REINFORCED IN AREAS AFFECTED BY
THE WORK. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL NECESSARY TEMPORARY SHORING,
BRACING, AND SUPPORTS TO MAINTAIN STRUCTURAL STABILITY DURING ALL DEMOLITION AND CONSTRUCTION
OPERATIONS. ALL NEW LOADS SHALL BE PROPERLY TRANSFERRED AND DISTRIBUTED IN ACCORDANCE WITH
THE STRUCTURAL CALCULATIONS AND IN COMPLIANCE WITH APPLICABLE CODES.
S1
14
S1
14
S2
14
S2
14
S3
14
S3
14
S4
14
S4
14
32'-8 1/2"
22'-4"
23'-9 1/2"
8'-10 1/2"
12'-1"
22'-4"
20'-11 1/2"
14'-9"
15'-10"
21'-10 1/2"
21'-1 1/2"
3'-8 1/2"
3'-2 1/2"
6'-7 1/2"
6'-7 1/2"
7 1/2"
5'-7 1/2"2'-9 1/2"
9'-4 1/2"
10'-3 1/2"
4'-3"25'-9 1/2"
11'-5" X 21'-0"
30'-0" X 21'-10"
14'-9" X 15'-10"
GARAGE
EXISTING FOUNDATION
PROPOSED
SLAB-ON-GRADE
EXISTING FOUNDATION WALL
PROPOSED FOUNDATION WALL
USE HYDRAULIC CEMENT AT JOINT BETWEEN FOUNDATIONS
WHILE BELOW GRADE AFTER DE-FORMING.
INSTALL #5 REBARS AT 12" O.C. W/ 10" MIN. EMBEDMENT EACH
WAY. INTO EXISTING FOUNDATION WALL AND NEW CONCRETE
FOUNDATION WALL. USE 2 PART EPOXY ADHESIVE TO EMBED
REBARS INTO EXISTING FOUNDATION WALL
FOUNDATION WALLS: REFER TO
FOUNDATION NOTES ON SHEET A-8
PROPOSED FOUNDATION WALL
EXISTING FOUNDATION WALL
FOUNDATION WALLS: REFER TO
FOUNDATION NOTES ON SHEET A-8
F1/F2
D-0
F1/F2
D-0
F1/F2
D-0
F1/F2
D-0
F1/F2
D-0
F1/F2
D-0
***STEM WALL FOUNDATION WITH SLAB-ON-GRADE: CONTINUOUS
CONCRETE FOOTING LOCATED 48" BELOW FINISHED GRADE (FROST
DEPTH). CONCRETE 3,000 PSI MINIMUM. FOOTINGS REINFORCED WITH
(2) #4 REBARS CONTINUOUS, ONE NEAR THE TOP AND ONE NEAR THE
BOTTOM OF THE FOOTING. 10" CONCRETE FOUNDATION WALLS
REINFORCED PER STRUCTURAL NOTES. INTERIOR STEM WALL
FOUNDATION TO REMAIN SOIL OR RECEIVE NON-STRUCTURAL MUD
SLAB (OPTIONAL). PROVIDE TERMITE PROTECTION AND FOUNDATION
INSULATION AS REQUIRED BY LOCAL CODE.
STEM WALL FOUNDATION WITH SLAB-ON-GRADE –
REFER TO FOUNDATION NOTES ON SHEET A-8.
PROPOSED 10" CONCRETE
FOUNDATION WALL ON 24" X
12" CONTINUOUS CONCRETE
FTG. 3000 PSI CONCRETE MIN.
BOTTOM OF FTG ON
UNDISTURBED SOIL.
PROPOSED 10" CONCRETE
FOUNDATION WALL ON 24" X
12" CONTINUOUS CONCRETE
FTG. 3000 PSI CONCRETE MIN.
BOTTOM OF FTG ON
UNDISTURBED SOIL.
PROPOSED 10" CONCRETE FOUNDATION WALL
ON 24" X 12" CONTINUOUS CONCRETE FTG. 3000
PSI CONCRETE MIN. BOTTOM OF FTG ON
UNDISTURBED SOIL.
ASSUMED EXISTING FOUNDATION WALL – VERIFY IN FIELD
PROPOSED 6" X 6" PT
POST WITH ALIGNED
FOUNDATION WALL
PROPOSED STAIR TO
DECK ABOVE
PROPOSED DECK
ABOVE
PROPOSED 6" X 6" PT POST WITH
SONOTUBE 12" W/ 48" DEEP
PROPOSED 6" X 6" PT
POST WITH SONOTUBE
12" W/ 48" DEEP
PROPOSED 6" X 6" PT
POST WITH SONOTUBE
12" W/ 48" DEEP
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
PROPOSED 6" X 6" PT
POST WITH ALIGNED
FOUNDATION WALL
PROPOSED 3 1/2" Ø LALLY COLUMN
WITH 24" x 24" x 12" FOOTING PAD W/
#5 HORIZONTAL BARS – TYP.
C08C08C08C08
C10C10
C32C32
C32C32
EXISTING
DOOR W01W01
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
DOOR
D02D02 EXISTING
DOORWAY
EXISTING
BUILT-IN CABINET
W03W03
D03D03
W04W04 W04W04
D04D04
D01D01
UP
SD
SD
SD
HD
CO/SD
E2
11
E2
11 S1
14
S1
14
S2
14
S2
14
S3
14
S3
14
S4
14
S4
14
IE1
15
IE1
15
IE2
15
IE2
15
12'-9"
14'-9"
12'-9"
20'-9"
10'-9"
8'-9"
11'-4"
21'
3'-5"
4'-7"
16'-1"
15'-3"
3'-10"7'-7"3'-10"
4'-2"
1'-10"
10'-1"
6'-3 1/2"
3'-3 1/2"
3'-8 1/2"
3'-2 1/2"
6'-7 1/2"
6'-7 1/2"
7 1/2"
5'-7 1/2"2'-9 1/2"
2'-11 1/2"
11'-4" X 21'-0"
14'-7" X 15'-10"
14'-9" X 12'-9"
12'-9" X 10'-9"
20'-9" X 9'-7"8'-11" X 9'-7"
3'-1" X 4'-11"
21'-4" X 4'-7"
EXISTING OPEN
MECHANICAL AREA
TO REMAIN
EXISTING
FIREPLACE
TO REMAIN
EXISTING DROPPED BEAM TO REMAIN
ASSUMED BEARING WALL – VERIFY IN FIELD
GARAGE LEVEL
0' - 4"
EXISTING WALL-MOUNTED SHELVES
PORCH TO PORCH
TOOL ROOM
FAMILY ROOM
UTILITY & PLAY AREA
BATH/
LAUNDRY
ENTRY
GARAGE TO REMAIN
STORAGE
PROPOSED STAIR
TO FIRST FLOOR
PROPOSED STAIR TO
DECK ABOVE
PROPOSED DECK
ABOVE
PROPOSED 6" X 6" PT POST WITH
SONOTUBE 12" W/ 48" DEEP
PROPOSED 6" X 6" PT
POST WITH SONOTUBE
12" W/ 48" DEEP
PROPOSED 6" X 6" PT
POST WITH SONOTUBE
12" W/ 48" DEEP
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
PROPOSED INTERIOR FIRE-RATED WALL (1-HOUR
ASSEMBLY):- 5/8" TYPE X GYPSUM BOARD EACH SIDE-
2" x 4" SPF #2 STUDS @ 16" OC- CAVITY INSULATION:
MINERAL WOOL OR R-13 FIBERGLASS BATT (WHERE
REQUIRED)- ASSEMBLY CONFORMS TO ASTM E119 / UL
U305 OR EQUIVALENT
WF2
D-0
WF2
D-0
W2
D-0
W2
D-0
PROPOSED 6" X 6" PT
POST WITH ALIGNED
FOUNDATION WALL
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
W1
D-0
W1
D-0PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
PROPOSED 3 1/2" Ø LALLY COLUMN
WITH 24" x 24" x 12" FOOTING PAD W/
#5 HORIZONTAL BARS – TYP.
9'-7"
EXISTING POST
TO REMAIN
EXISTING POST
TO REMAIN
9'-7"
8'-10 1/2"
22'-2 1/2"
WALL SCHEDULE
2D SYMBOL WALL TYPE
16" CONCRETE STEM WALL
EXISTING CONCRETE WALL
PORPOSED CONCRETE WALL
EXISTING EXTERIOR BRICK WALL
EXISTING EXTERIOR WALL
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL - 6
EXISTING INTERIOR WALL - 8
PROPOSED EXTERIOR WALL
PROPOSED BEARING INTERIOR WALL
PROPOSED INTERIOR WALL
GLASS SHOWER
PROPOSED FIRE RESISTANCE WALL
INTERIOR RAILING
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-8
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED PLANS
PROPOSED GROUND PLAN
SCALE: 1/4" = 1'-0"
PROPOSED FOUNDATION PLAN
SCALE: 1/4" = 1'-0"
NOTE 01 – FOUNDATION AND SLAB REQUIREMENTS
FROST PROTECTION:
ALL FOUNDATIONS SHALL EXTEND TO A MINIMUM DEPTH OF 48
INCHES BELOW FINISHED GRADE TO COMPLY WITH FROST LINE
REQUIREMENTS PER IRC 2021 SECTION R403.1.4.1 AND APPLICABLE
LOCAL CODE AMENDMENTS.
FROST WALL CONSTRUCTION:
PROVIDE A 10-INCH CONCRETE FROST WALL ALONG THE
TRANSITION BETWEEN THE EXISTING BASEMENT FOUNDATION AND
THE NEW SLAB-ON-GRADE AREA. THE FROST WALL SHALL BE
REINFORCED AND EXTEND AT LEAST 48 INCHES BELOW GRADE.
THERMAL INSULATION:
PROVIDE A MINIMUM R-15 CONTINUOUS RIGID INSULATION ON THE
EXTERIOR FACE OF THE FROST WALL PER IRC 2021 SECTION
N1102.2.10 (R402.2.10) AND IECC 2021 TABLE R402.1.3 FOR SLAB
EDGE INSULATION IN CLIMATE ZONE 5.
VAPOR BARRIER:
A VAPOR RETARDER SHALL BE PROVIDED BENEATH THE SLAB
USING A MINIMUM 6-MIL POLYETHYLENE SHEET, LAPPED AT LEAST
6 INCHES AND SEALED, AS REQUIRED BY IRC 2021 SECTION
R506.2.3.
COMPACTED BASE:
SLABS SHALL BE POURED OVER A MINIMUM OF 4 INCHES OF CLEAN,
COMPACTED GRAVEL OR CRUSHED STONE PER IRC 2021 SECTION
R506.2.2.
SLAB REINFORCEMENT (IF REQUIRED):
REINFORCE SLAB WITH WELDED WIRE MESH OR REINFORCING
BARS AS SPECIFIED IN THE STRUCTURAL DESIGN.
REINFORCEMENT SHALL BE PROPERLY SUPPORTED AND SHALL
NOT BE PLACED DIRECTLY ON THE SUB-BASE.
CONNECTION TO EXISTING FOUNDATION:
PROVIDE MECHANICAL CONNECTION BETWEEN NEW AND EXISTING
FOUNDATIONS USING DOWELS OR EPOXY-SET REINFORCING BARS
TO ENSURE STRUCTURAL CONTINUITY AND MINIMIZE DIFFERENTIAL
MOVEMENT.
TRANSITION DETAIL:
PROVIDE A THERMAL BREAK AND WATERPROOFING AT THE
INTERFACE BETWEEN THE SLAB-ON-GRADE AND THE EXISTING
BASEMENT WALL TO PREVENT THERMAL BRIDGING AND WATER
INTRUSION.
FOUNDATION DRAINAGE (IF APPLICABLE):
WHERE REQUIRED BY SITE CONDITIONS, PROVIDE A PERIMETER
DRAINAGE SYSTEM IN ACCORDANCE WITH IRC 2021 SECTION
R405.1.
INSPECTION REQUIREMENTS:
ALL FOUNDATION EXCAVATION AND WORK SHALL BE SUBJECT TO
INSPECTION AND APPROVAL BY THE TOWN OF WINDHAM BUILDING
DEPARTMENT PRIOR TO BACKFILLING AND CONCRETE PLACEMENT.
TRIM AND FINISH NOTES
1. CONTRACTOR SHALL VERIFY ALL TRIM DETAILS IN THE FIELD. IN
THE EVENT OF ANY DISCREPANCIES, NOTIFY THE DESIGNER
IMMEDIATELY.
2. ALL TRIM SHALL BE APPLIED USING STAINLESS STEEL FINISH
NAILS.
3. NAIL HOLES SHALL BE FILLED AND SANDED SMOOTH WITH WOOD
FILLER OR BONDO PRIOR TO FINISHING.
4. CLEAN ALL TRIM SURFACES PRIOR TO PAINTING WITH
DENATURED ALCOHOL IMMEDIATELY BEFORE APPLICATION.
5. TRIM SHALL RECEIVE A MINIMUM OF TWO COATS OF 100%
ACRYLIC PAINT, SUCH AS SHERWIN-WILLIAMS DURATION OR
APPROVED EQUAL.
6. APPLY PRIMER AND TWO FINISH COATS OF PAINT. FINAL COLOR
AND FINISH SHALL BE APPROVED BY THE OWNER.
7. CONTRACTOR SHALL PROVIDE PROPER FLASHING AT ALL
APPLICABLE LOCATIONS.
8. PROVIDE WATER BARRIER AND VAPOR BARRIER AS REQUIRED.
***NOTE – EXISTING FOUNDATION CONDITIONS – FIELD VERIFICATION REQUIRED- EXISTING FOUNDATION AND BEARING
CONDITIONS ARE PARTIALLY CONCEALED AND COULD NOT BE FULLY VERIFIED AT THE TIME OF DOCUMENTATION. BASED ON
LIMITED OBSERVATIONS, THE STRUCTURE APPEARS TO BE SUPPORTED BY A COMBINATION OF DISCONTINUOUS CMU ELEMENTS,
ISOLATED BEARING POINTS, AND DIRECT BEARING ON SOIL/ROCK.- THE CONTRACTOR SHALL FULLY EXPOSE AND VERIFY ALL
EXISTING FOUNDATION AND BEARING CONDITIONS PRIOR TO THE START OF CONSTRUCTION, INCLUDING DEPTH,
EXTENT, CONTINUITY, AND STRUCTURAL CAPACITY.- ANY EXISTING ELEMENTS FOUND TO BE INADEQUATE, DETERIORATED,
UNSUPPORTED, OR NOT MEETING CURRENT CODE REQUIREMENTS SHALL NOT BE RELIED UPON FOR STRUCTURAL SUPPORT
AND SHALL BE REPAIRED, REPLACED, OR SUPPLEMENTED AS REQUIRED TO SAFELY SUPPORT ALL IMPOSED LOADS.- ALL NEW
AND FINAL FOUNDATION WORK SHALL BE CONSTRUCTED IN ACCORDANCE
WITH THE PROPOSED FOUNDATION SYSTEM INDICATED IN THESE DRAWINGS. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY
THE DESIGN PROFESSIONAL IF FIELD
CONDITIONS DIFFER FROM THOSE ASSUMED, AND NO STRUCTURAL WORK SHALL
PROCEED UNTIL APPROPRIATE DIRECTION IS PROVIDED.- EXISTING FOUNDATION AND BEARING CONDITIONS ARE PARTIALLY
CONCEALED AND COULD NOT BE FULLY VERIFIED AT THE TIME OF DOCUMENTATION. BASED ON LIMITED OBSERVATIONS, THE
STRUCTURE APPEARS TO BE SUPPORTED BY A COMBINATION OF DISCONTINUOUS FOUNDATION ELEMENTS, ISOLATED BEARING
POINTS, AND AREAS BEARING DIRECTLY ON SOIL AND/OR ROCK.- THE EXTENT, DEPTH, CONTINUITY, AND STRUCTURAL
ADEQUACY OF THE EXISTING
FOUNDATION SYSTEM REMAIN UNKNOWN DUE TO CONCEALED BELOW-GRADE
CONDITIONS.- CONTRACTOR SHALL VERIFY ALL EXISTING FOUNDATION AND BEARING CONDITIONS IN FIELD PRIOR TO THE
COMMENCEMENT OF WORK AND NOTIFY THE DESIGN
PROFESSIONAL OF ANY DISCREPANCIES, DEFICIENCIES, OR CONDITIONS REQUIRING
MODIFICATION.
***NOTE – STEM WALL FOUNDATION WITH SLAB-ON-GRADE- FROST PROTECTION: ALL FOUNDATION FOOTINGS AND
STEM WALLS SHALL EXTEND TO A MINIMUM DEPTH OF 48 INCHES BELOW FINISHED GRADE, IN ACCORDANCE WITH
2021 IRC SECTION R403.1.4.1 AND LOCAL FROST DEPTH REQUIREMENTS.- STEM WALLS: PROVIDE 10" REINFORCED
CONCRETE STEM WALLS FORMING THE PERIMETER OF THE FOUNDATION SYSTEM. WALLS SHALL BE REINFORCED
PER STRUCTURAL DESIGN AND SHALL BEAR ON CONTINUOUS CONCRETE FOOTINGS PLACED ON UNDISTURBED
SOIL.- SLAB-ON-GRADE: PROVIDE A REINFORCED CONCRETE SLAB-ON-GRADE AS SPECIFIED IN STRUCTURAL
DOCUMENTS. SUBGRADE SHALL BE PROPERLY COMPACTED AND PREPARED TO RECEIVE VAPOR CONTROL AND
INSULATION, WHERE REQUIRED.- VAPOR BARRIER: INSTALL A 6-MIL (MIN.) POLYETHYLENE VAPOR RETARDER
DIRECTLY BELOW THE SLAB-ON-GRADE, WITH 6" MINIMUM OVERLAP AND SEALED JOINTS, IN ACCORDANCE WITH
IRC SECTION R506.2.3.- CONNECTION TO EXISTING FOUNDATION: PROVIDE MECHANICAL CONNECTION BETWEEN
NEW AND EXISTING FOUNDATION WALLS USING DOWELS OR EPOXY-SET #4 REBAR, PER STRUCTURAL DESIGN, TO
ENSURE CONTINUITY AND MINIMIZE DIFFERENTIAL MOVEMENT.- THERMAL INSULATION – FOUNDATION WALLS:
WHEN REQUIRED BY ENERGY CODE, PROVIDE MINIMUM R-10 CONTINUOUS INSULATION ON THE INTERIOR OR
EXTERIOR FACE OF THE STEM WALLS, PER 2021 IRC SECTION N1102.2.10 (R402.2.10) AND IECC CLIMATE ZONE 5
REQUIREMENTS.- SLAB INSULATION (WHEN REQUIRED): WHERE ENERGY CODE MANDATES, PROVIDE SLAB-EDGE
INSULATION PER IECC REQUIREMENTS FOR CLIMATE ZONE 5.- TERMITE PROTECTION: PROVIDE TERMITE
PROTECTION AT ALL STEM WALLS, SLAB PENETRATIONS, AND PERIMETERS AS REQUIRED BY IRC SECTION R318
AND LOCAL CODES.- FOUNDATION DRAINAGE: WHERE REQUIRED BY SITE CONDITIONS, INSTALL A PERIMETER
DRAINAGE SYSTEM IN ACCORDANCE WITH IRC SECTION R405.1, INCLUDING FILTER FABRIC, GRAVEL BEDDING, AND
DISCHARGE TO AN APPROVED OUTLET.- INSPECTIONS: ALL EXCAVATION, FOOTINGS, STEM WALLS, DAMP-
PROOFING, VAPOR CONTROL, SLAB PREPARATION, AND CONNECTIONS TO EXISTING FOUNDATION SHALL BE
SUBJECT TO BUILDING DEPARTMENT INSPECTION AND APPROVAL PRIOR TO CONCRETE PLACEMENT AND FRAMING.
***NOTE – EXISTING EXTERIOR WALL CONDITION NOTE-EXISTING EXTERIOR WALL ASSEMBLIES ARE OF OLDER WOOD PLANK
CONSTRUCTION AND WERE OBSERVED IN AGED AND WEATHERED CONDITION AT THE TIME OF DOCUMENTATION. - CONCEALED
CONDITIONS MAY EXIST WITHIN WALL CAVITIES AND FRAMING CONNECTIONS. THE EXTENT OF DETERIORATION, AIR LEAKAGE,
MOISTURE DAMAGE, AND STRUCTURAL
ADEQUACY COULD NOT BE FULLY VERIFIED WITHOUT SELECTIVE REMOVAL OF FINISHES AND/OR WALL COMPONENTS.-
CONTRACTOR SHALL VERIFY ALL EXISTING WALL CONDITIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK AND NOTIFY THE
DESIGN PROFESSIONAL OF ANY CONCEALED DAMAGE,
DETERIORATION, SETTLEMENT, DEFLECTION, OR STRUCTURAL DEFICIENCY REQUIRING ADDITIONAL REPAIR OR MODIFICATION.-
ALL EXISTING EXTERIOR WALLS TO REMAIN SHALL BE REPAIRED AND UPGRADED AS REQUIRED TO PROVIDE A SOUND, CODE-
COMPLIANT WALL ASSEMBLY. REPAIR WORK SHALL INCLUDE
REPLACEMENT OF DETERIORATED OR DEFICIENT WOOD FRAMING AND SHEATHING COMPONENTS AS NECESSARY TO CREATE A
STABLE SUBSTRATE FOR NEW CONSTRUCTION.- PROVIDE NEW WEATHER-RESISTIVE BARRIER, AIR SEALING, INSULATION, AND
INTERIOR/EXTERIOR FINISHES AS REQUIRED BY THE PROPOSED DESIGN AND APPLICABLE ENERGY CODE.
WHERE EXISTING WALL CONSTRUCTION DOES NOT PERMIT THE INTENDED ASSEMBLY, CONTRACTOR SHALL PROVIDE FURRING,
REFRAMING, OR OTHER APPROVED CORRECTIVE MEASURES
AS REQUIRED TO ACHIEVE THE SPECIFIED WALL SYSTEM AND THERMAL PERFORMANCE.- FINAL WALL ASSEMBLY SHALL COMPLY
WITH THE APPROVED DRAWINGS, IRC 2021, 780 CMR, AND APPLICABLE MASSACHUSETTS ENERGY CODE REQUIREMENTS
C22C22C22C22
C24C24C24C24
C24C24C24C24
C08C08C08C08
C23C23C23C23C23C23C23C23C23C23C23C23
DN
C19C19
C13C13C13C13
C11C11
C12C12
C26C26
C05C05
C26C26
C19C19
C13C13C13C13
C11C11
C12C12
C26C26
C05C05
C26C26
C18C18
C15C15
C16C16
C15C15
C16C16
C20C20
C21C21
EXISTING
DOOR W02W02 W01W01 EXISTING
WINDOW
D05D05D01D01
W03W03
W03W03
W03W03
EXISTING
WINDOWW06W06
EXISTING
WINDOW
W03W03
D06D06
D04D04D01D01D01D01
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
D07D07
W03W03W05W05W03W03
UP
UP
CO/SD
SD
SD
SD
SD
SD
S1
14
S1
14
S2
14
S2
14
S3
14
S3
14
S4
14
S4
14
IE3
15
IE3
15
IE4
15
IE4
15
IE5
15
IE5
15
IE6
15
IE6
15
IE7
15
IE7
15
IE8
15
IE8
15
IE9
15
IE9
15
5'
3'-1 1/2"
9'-5"
6'
3'-1 1/2"
15'-7"
9'-11"
9'-2"
15'-3"
16'-1"
23'-4 1/2"
7'-10"
9'-11"
5'-4"
4'-7"
9'-5"
14'-2 1/2"
14'-11"
8'-3"
7'
12'-9 1/2"
4'
3'-4 1/2"
3'
3'-1"3'-1"5'-5"3'-4"
4'-9"
7'-6"
5'-10 1/2"
1'-7 1/2"
27'-3 1/2"
3'
3'
5'-1 1/2"3'
3'
7'-4 1/2"
3'
3'
2'-1"
15'-4" X 13'-1"
9'-2" X 9'-11"
15'-3" X 16'-1"
2'-4" X 4'-3"
3'-9" X 7'-11"
6'-0" X 9'-5"
14'-2" X 9'-5"
15'-5" X 3'-4"
13'-10" X 10'-3"
7'-6" X 9'-11"
12'-5" X 10'-3"
5'-0" X 3'-2"
7'-0" X 15'-10"
LIVING
PANTRY
FAN PLAY
ROOM
SP BEDROOM 1
STAIRWELL
C. OFFICE
CLOSET
EXISTING
FIREPLACE
TO REMAIN
ASSUMED BEARING WALL – VERIFY IN FIELDPROPOSED FLUSH BEAM: STEEL BEAM W10×77
PROPOSED 6" X 6" HSS STEEL POST
WITH ALIGNED FOUNDATION WALL
DINING
CLOSET
BATH
KITCHEN
DECK
PROPOSED STAIR
TO SECOND FLOOR
PROPOSED
STAIR TO DECK
PROPOSED INTERIOR FIRE-RATED WALL (1-HOUR
ASSEMBLY):- 5/8" TYPE X GYPSUM BOARD EACH SIDE-
2" x 4" SPF #2 STUDS @ 16" OC- CAVITY INSULATION:
MINERAL WOOL OR R-13 FIBERGLASS BATT (WHERE
REQUIRED)- ASSEMBLY CONFORMS TO ASTM E119 / UL
U305 OR EQUIVALENT
WF2
D-0
WF2
D-0
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
EXTERIOR WALL TO REMAIN
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
HALL
PROJECTION: PROPOSED 6" X 6" POST
WITH ALIGNED THE BEAM
D4
D-0
D4
D-0
D1/D2/D5
D-0
D1/D2/D5
D-0
D1/D2/D5
D-0
D1/D2/D5
D-0
E1/E3
D-0
E1/E3
D-0
E1/E2
D-0
E1/E2
D-0
C09C09
C04C04
C02C02
C04C04
PROPOSED 6" X 6" HSS STEEL POST
WITH ALIGNED BEARING WALL
C03C03
10'-5 1/2"
C01C01
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
7'-7"
SB1/PB
D-0
SB1/PB
D-0
C06C06
18'-7 1/2"
26'-2 1/2"
DN
C27C27
C07C07
C07C07
C25C25 C29C29C31C31
C27C27
C07C07
C07C07
C25C25 C29C29C31C31
C17C17
C14C14
C28C28 C30C30
W03W03
W03W03
D02D02
W03W03
D01D01D01D01
W01W01 W01W01 W03W03
W03W03
D01D01
D06D06
D06D06
D01D01D09D09D01D01
D08D08
D01D01
W03W03W03W03W03W03W03W03
D06D06
D01D01
D01D01
SD
SD
SD
SD
SD
SD
CO/SD
CO/SD
S1
14
S1
14
S2
14
S2
14
S3
14
S3
14
S4
14
S4
14
IE10
15
IE10
15
IE11
15
IE11
15
IE12
15
IE12
15
IE13
15
IE13
15
IE14
15
IE14
15 IE15
15
IE15
15
IE16
15
IE16
15
6'-11"
8'-10"
15'-3"
16'-1 1/2"
12'-11"
9'-8"
2'-4"
4'-6"
4'-5"
2'-4"
9'-3"
9'-3"
14'-11"3'
13'-3"
9'-11"
9'-11"
5'-4"
4'-7"
4'-10"
7'-6"
3'-1"
5'
9'-10 1/2"
3'
4'-6 1/2"
8'-9"
3'-3 1/2"
9'-8"
3'-4"
23'-0 1/2"
3'-10 1/2"11'-4 1/2"
7'-11"
13'-0" X 9'-3"
15'-3" X 8'-10"
13'-10" X 13'-9"
9'-8" X 12'-11"8'-9" X 9'-3"
3'-3" X 8'-8"
2'-4" X 4'-5"
2'-4" X 4'-6"
2'-10" X 1'-0"
4'-10" X 9'-11"
1'-6" X 5'-11"
13'-3" X 9'-11"
7'-6" X 9'-11"
2'-4" X 4'-3"
3'-0" X 5'-0"
23'-0" X 3'-4"
WALK-IN CLOSET
SP BEDROOM 2
CLOSET
CLOSET
SP. ROOM
CLOSET
T OFFICE
PROPOSED FLUSH BEAM: STEEL BEAM W8×40
PROPOSED 6" X 6" HSS STEEL
POST WITH ALIGNED THE BEAM
PROPOSED 6" X 6" HSS STEEL
POST WITH ALIGNED THE BEAM CLOSET
R. BEDROOM
BATH
SHOWERMASTER BEDROOM
MASTER BATH
STAIRWELL
HALL
PROPOSED BEARING WALL
PROPOSED ATTIC LADDER
CLOSET
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
PROPOSED INTERIOR WALL:
- 2" x 6" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
PROPOSED INTERIOR BEARING WALL:
- 2" x 6" SPF No.2 STUDS @ 16" O.C.
- CAVITY INSULATION: R-13 MIN. (WHERE REQUIRED)
- 1/2" GYPSUM BOARD EACH SIDE
PROPOSED INTERIOR BEARING WALL:
- 2" x 6" SPF No.2 STUDS @ 16" O.C.
- CAVITY INSULATION: R-13 MIN. (WHERE REQUIRED)
- 1/2" GYPSUM BOARD EACH SIDE
PROPOSED BEARING WALL
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH SIDES)
WF2
D-0
WF2
D-0
WF2
D-0
WF2
D-0
WF2
D-0
WF2
D-0
PROPOSED INTERIOR FIRE-RATED WALL (1-HOUR
ASSEMBLY):- 5/8" TYPE X GYPSUM BOARD EACH SIDE-
2" x 4" SPF #2 STUDS @ 16" OC- CAVITY INSULATION:
MINERAL WOOL OR R-13 FIBERGLASS BATT (WHERE
REQUIRED)- ASSEMBLY CONFORMS TO ASTM E119 / UL
U305 OR EQUIVALENT
EXISTING BRICK CHIMNEY TO
REMAIN AND EXTEND THROUGH
NEW CONSTRUCTION TO
TERMINATE ABOVE ROOF IN
COMPLIANCE WITH IRC 2021.
PROPOSED ATTIC LADDER
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
WALL SCHEDULE
2D SYMBOL WALL TYPE
16" CONCRETE STEM WALL
EXISTING CONCRETE WALL
PORPOSED CONCRETE WALL
EXISTING EXTERIOR BRICK WALL
EXISTING EXTERIOR WALL
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL - 6
EXISTING INTERIOR WALL - 8
PROPOSED EXTERIOR WALL
PROPOSED BEARING INTERIOR WALL
PROPOSED INTERIOR WALL
GLASS SHOWER
PROPOSED FIRE RESISTANCE WALL
INTERIOR RAILING
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-9
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED PLANS
PROPOSED FIRST FLOOR PLAN
SCALE: 1/4" = 1'-0"
PROPOSED SECOND FLOOR PLAN
SCALE: 1/4" = 1'-0"
***NOTE – EXISTING EXTERIOR WALL CONDITION NOTE-EXISTING EXTERIOR WALL ASSEMBLIES ARE OF OLDER WOOD PLANK
CONSTRUCTION AND WERE OBSERVED IN AGED AND WEATHERED CONDITION AT THE TIME OF DOCUMENTATION. - CONCEALED
CONDITIONS MAY EXIST WITHIN WALL CAVITIES AND FRAMING CONNECTIONS. THE EXTENT OF DETERIORATION, AIR LEAKAGE,
MOISTURE DAMAGE, AND STRUCTURAL
ADEQUACY COULD NOT BE FULLY VERIFIED WITHOUT SELECTIVE REMOVAL OF FINISHES AND/OR WALL COMPONENTS.-
CONTRACTOR SHALL VERIFY ALL EXISTING WALL CONDITIONS IN FIELD PRIOR TO COMMENCEMENT OF WORK AND NOTIFY THE
DESIGN PROFESSIONAL OF ANY CONCEALED DAMAGE,
DETERIORATION, SETTLEMENT, DEFLECTION, OR STRUCTURAL DEFICIENCY REQUIRING ADDITIONAL REPAIR OR MODIFICATION.-
ALL EXISTING EXTERIOR WALLS TO REMAIN SHALL BE REPAIRED AND UPGRADED AS REQUIRED TO PROVIDE A SOUND, CODE-
COMPLIANT WALL ASSEMBLY. REPAIR WORK SHALL INCLUDE
REPLACEMENT OF DETERIORATED OR DEFICIENT WOOD FRAMING AND SHEATHING COMPONENTS AS NECESSARY TO CREATE A
STABLE SUBSTRATE FOR NEW CONSTRUCTION.- PROVIDE NEW WEATHER-RESISTIVE BARRIER, AIR SEALING, INSULATION, AND
INTERIOR/EXTERIOR FINISHES AS REQUIRED BY THE PROPOSED DESIGN AND APPLICABLE ENERGY CODE.
WHERE EXISTING WALL CONSTRUCTION DOES NOT PERMIT THE INTENDED ASSEMBLY, CONTRACTOR SHALL PROVIDE FURRING,
REFRAMING, OR OTHER APPROVED CORRECTIVE MEASURES
AS REQUIRED TO ACHIEVE THE SPECIFIED WALL SYSTEM AND THERMAL PERFORMANCE.- FINAL WALL ASSEMBLY SHALL COMPLY
WITH THE APPROVED DRAWINGS, IRC 2021, 780 CMR, AND APPLICABLE MASSACHUSETTS ENERGY CODE REQUIREMENTS.
PROPOSED 3D VIEW
SCALE: NO SCALE
***NOTE – CHIMNEY:
PROPOSED EXTENSION OF EXISTING
EXTERIOR MASONRY CHIMNEY. THE
CHIMNEY SHALL BE MAINTAINED AS A
CONTINUOUS VERTICAL ELEMENT
EXTENDING THROUGH THE ROOF, WITH
NO FIREPLACE CONNECTION AT THE
SECOND FLOOR LEVEL, AND SHALL BE
FULLY ENCLOSED WITHIN A FRAMED
CHASE. PROVIDE REQUIRED CLEARANCE
BETWEEN MASONRY CHIMNEY AND
COMBUSTIBLE FRAMING IN ACCORDANCE
WITH APPLICABLE CODES; DO NOT ALLOW
DIRECT CONTACT. CHIMNEY HEIGHT
ABOVE ROOF SHALL COMPLY WITH IRC
2021 SECTION R1003.9. PROVIDE
APPROVED FLASHING AND
COUNTERFLASHING AT THE CHIMNEY/
ROOF INTERSECTION PER IRC R903.2.
VERIFY CHIMNEY STRUCTURAL STABILITY
AND SUPPORT CONDITIONS FOR THE
PROPOSED EXTENSION HEIGHT.
***ALL EXISTING WALLS SHALL BE VERIFIED IN FIELD FOR LOCATION, DIMENSIONS, AND STRUCTURAL CAPACITY.
ANY WALLS SUPPORTING NEW LOADS SHALL BE EVALUATED AND REINFORCED AS REQUIRED.
***NOTE – EXISTING STRUCTURE: THE EXISTING STRUCTURE HAS NOT BEEN FULLY VERIFIED. ALL LOAD-BEARING
ELEMENTS, INCLUDING WALLS, BEAMS, AND FOUNDATIONS, SHALL BE FIELD VERIFIED FOR ADEQUACY TO SUPPORT NEW
LOADS. ANY DEFICIENCIES SHALL BE REPORTED AND CORRECTED PRIOR TO CONTINUATION OF WORK.
W07W07
W07W07
W07W07
S1
14
S1
14
S2
14
S2
14
S3
14
S3
14
S4
14
S4
14
15'-3"
16'-8"
28'-4 1/2"
23'-4 1/2"
43'-7 1/2"
40'-0 1/2"
11'-8 1/2"
11'-8"
28'-1"
11'-11 1/2"
7'-7 1/2"7'-7 1/2"
STORAGE
43'-7" X 23'-4"
PROPOSED ATTIC LADDER
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER
SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5
CONTINUOUS EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2X6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
W1
D-0
W1
D-0
8 : 12
4 : 12
8 : 12
8 : 12
8 : 12
8 : 12
19'
17'-2"
16'-11 1/2"
13'-7"
28'-4"
13'-1"
13'-3 1/2"
13'-8 1/2"
47'-4"
13'-2"
1 3 '-5 1 /2 "
9'-6"9'-6"
26'-8"
3'-7"
PROPOSED ROOF
PROPOSED ROOF
***BOTH ROOF SYSTEMS ARE NEW.
THE SMALLER ROOF IS LOCATED ABOVE AND
OVER THE MAIN ROOF AT A DIFFERENT
ELEVATION, CHARACTERIZING AN OVERLAY
CONDITION.
NO DIRECT FRAMING CONNECTION IS
INTENDED BETWEEN THE TWO ROOF SYSTEMS.
EXISTING LOWER ROOF
SD
D-0
SD
D-0
R2
D-0
R2
D-0
SD
D-0
SD
D-0
R2
D-0
R2
D-0
SD
D-0
SD
D-0
R2
D-0
R2
D-0
SD
D-0
SD
D-0
R2
D-0
R2
D-0
R1
D-0
R1
D-0
R1
D-0
R1
D-0
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
PROPOSED ROOF PROPOSED ROOF
WINDOW SCHEDULE
3D EXTERIOR
ELEVATION NUMBER QTY WIDTH HEIGHT R/O EGRESS U-FACTOR DESCRIPTION
W01 4 32 "30 "33"X31"0.3 SINGLE AWNING
W02 1 32 "36 "33"X37"0.3 DOUBLE CASEMENT-LHL/RHR
W03 16 32 "48 "33"X49"0.3 DOUBLE HUNG
W04 2 44 "48 "45"X49"0.3 DOUBLE HUNG
W05 1 36 "48 "37"X49"0.3 FIXED GLASS
W06 1 32 "36 "33"X37"0.3 DOUBLE HUNG
W07 3 28 "22 "29"X23"0.3 LOUVERED
DOOR SCHEDULE
3D EXTERIOR
ELEVATION NUMBER HEIGHT WIDTH QTY U-FACTOR R/O DESCRIPTION
D01 80 "30 "12 0.3 32"X82 1/2"HINGED-DOOR P04
D02 80 "30 "2 0.3 61 1/4"X82 1/2"POCKET-DOOR P04
D03 80 "36 "1 0.3 38"X83"EXT. HINGED-DOOR E01
D04 80 "48 "2 0.3 50"X82 1/2"SLIDER-DOOR P04
D05 80 "29 1/2 "2 0.3 31 1/2"X82 1/2"HINGED-DOOR P04
D06 80 "42 "4 0.3 44"X82 1/2"SLIDER-DOOR P04
D07 80 "60 "1 0.3 62"X83"EXT. SLIDER-GLASS PANEL
D08 80 "60 "1 0.3 62"X82 1/2"SLIDER-DOOR P04
D09 80 "24 "1 0.3 26"X82 1/2"2 DR. BIFOLD-LOUVERED
WALL SCHEDULE
2D SYMBOL WALL TYPE
16" CONCRETE STEM WALL
EXISTING CONCRETE WALL
PORPOSED CONCRETE WALL
EXISTING EXTERIOR BRICK WALL
EXISTING EXTERIOR WALL
EXISTING INTERIOR WALL
EXISTING INTERIOR WALL - 6
EXISTING INTERIOR WALL - 8
PROPOSED EXTERIOR WALL
PROPOSED BEARING INTERIOR WALL
PROPOSED INTERIOR WALL
GLASS SHOWER
PROPOSED FIRE RESISTANCE WALL
INTERIOR RAILING
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-10
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED ATTIC PLAN
SCALE: 1/4" = 1'-0"PROPOSED PLANS
SCHEDULES
PROPOSED ROOF PLAN
SCALE: 1/4" = 1'-0"
EXISTING
DOOR
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
W06W06
W03W03 W03W03W05W05
W03W03 W03W03W03W03 W03W03
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
PROPOSED ROOF LEVEL
33' - 7"
PROPOSED SECOND FLOOR LEVEL
16' - 10"
PROPOSED ATTIC LEVEL
25' - 3"
EXISTING
DOOR
EXISTING
DOOR
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
W06W06
W03W03 W03W03W05W05
W03W03 W03W03W03W03 W03W03
W03W03W03W03W03W03
W03W03
W07W07
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
PROPOSED ROOF LEVEL
33' - 7"
PROPOSED SECOND FLOOR LEVEL
16' - 10"
PROPOSED ATTIC LEVEL
25' - 3"
W03W03W03W03W03W03
W03W03
W07W07
W01W01
W04W04 W04W04
W03W03
W01W01 W01W01
W07W07
W02W02
EXISTING
WINDOW
W01W01
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
PROPOSED ROOF LEVEL
33' - 7"
PROPOSED SECOND FLOOR LEVEL
16' - 10"
PROPOSED ATTIC LEVEL
25' - 3"
W01W01
W04W04 W04W04
W03W03
W01W01 W01W01
W07W07
W02W02
EXISTING
WINDOW
W01W01
EXISTING
WINDOW
EXISTING
WINDOW
EXISTING
WINDOW
D03D03
W03W03
EXISTING
WINDOW
EXISTING
WINDOWW03W03
D07D07
W03W03W03W03 W03W03
W07W07
EXISTING GARAGE LEVEL
0' - 4"
EXISTING GROUND LEVEL
0' - 0"
EXISTING FIRST FLOOR LEVEL
8' - 5"
PROPOSED ROOF LEVEL
32' - 7"
PROPOSED SECOND FLOOR LEVEL
16' - 10"
PROPOSED ATTIC LEVEL
25' - 3"
D03D03
W03W03
EXISTING
WINDOW
EXISTING
WINDOWW03W03
D07D07
W03W03W03W03 W03W03
W07W07
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-11
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED EXTERIOR ELEVATIONS
PROPOSED ELEVATION - FRONT
SCALE: 1/4" = 1'-0"
PROPOSED ELEVATION - LEFT
SCALE: 1/4" = 1'-0"
PROPOSED ELEVATION - BACK
SCALE: 1/4" = 1'-0"
PROPOSED ELEVATION - RIGHT
SCALE: 1/4" = 1'-0"
3'-8 1/2"
5 1/2"
6'-7 1/2"
5'-7 1/2"2'-9 1/2"
6'-7 1/2"
7 1/2"
2'-11 1/2"
EXISTING DROPPED BEAM TO REMAIN
ASSUMED BEARING WALL – VERIFY IN FIELD
PROPOSED STAIR TO
DECK ABOVE
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0
SO
D-0SO
D-0
SO
D-0
0101
0101
0101
0101 01010101
0101
0101
0101
0202
0202
0303 0303 0303
2X8" PT DECK JOISTS @ 16" O.C
please, see the table R507.6
2X8" PT LEDGER CARRIAGE
BOLTS @ 16" O.C
RL1/RL2
D-0
RL1/RL2
D-0
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
PROPOSED 3 1/2" Ø LALLY COLUMN WITH 24" x 24" x 12"
FOOTING PAD W/ #5 HORIZONTAL BARS – TYP.
0505 0505
0505
0404
0505
0505
0404 0404
0404 0404
0404
0404
0505
0505
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
CP1
D-0
CP1
D-0
EXISTING POST
TO REMAIN
EXISTING POST
TO REMAIN
7'-5"13'-3"
9'-10"1'-4"
16'-3"
16'-6"
10'-8 1/2"
13'-8"
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAINEXISTING JOIST TO REMAIN
EXISTING JOIST TO REMAIN
ASSUMED BEARING WALL – VERIFY IN FIELDPROPOSED FLUSH BEAM: STEEL BEAM W10×77
PROPOSED 6" X 6" HSS STEEL POST
WITH ALIGNED FOUNDATION WALL PROPOSED 6" X 6" HSS STEEL POST
WITH ALIGNED BEARING WALL
DECK
PROPOSED
STAIR TO DECK
PROPOSED (2) 2"X8" FLOOR JOISTS
PROPOSED (2) 2"X8" FLOOR JOISTS
PROPOSED (2) 2"X8" FLOOR JOISTS
PROPOSED (2) 2"X8" FLOOR JOISTS
PROPOSED HEADER (2) 2"X8"
PROPOSED HEADER (2) 2"X8"
PROPOSED HEADER (2) 2"X8"
PROJECTION: PROPOSED 6" X 6" POST
WITH ALIGNED THE BEAM
0404
0505
0505
0505 0505 04040404
0404
04040505
0505
0505
0505
0505 0505
0505
0505
0505
0505
2X10" FLOOR JOISTS @ 16" O.C.
PLEASE, SEE THE TABLE R502.3.1 (2)
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
PLEASE SEE NOTE "EXISTING FLOOR JOISTS –
FIELD VERIFICATION REQUIRED" ON PAGE A-12.
NOTE SCHEDULE
PROPOSED 6" X 6" PT POST
PROPOSED STRUCTURAL: (3) 2"X12" PT DROOPED BEAM
1
2
PROPOSED STRUCTURAL: (3) 2"X10" PT DROOPED BEAM3
EXISTING HEADER: SEE TABLE 4
NEW HEADER: SEE TABLE R602.7(2)5
NOTE SCHEDULE
PROPOSED 6" X 6" PT POST
PROPOSED STRUCTURAL: (3) 2"X12" PT DROOPED BEAM
1
2
PROPOSED STRUCTURAL: (3) 2"X10" PT DROOPED BEAM3
EXISTING HEADER: SEE TABLE 4
NEW HEADER: SEE TABLE R602.7(2)5
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-12
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED FRAME PLANS
PROPOSED SECOND FLOOR FRAME PLAN
SCALE: 1/4" = 1'-0"PROPOSED FIRST FLOOR FRAME PLAN
SCALE: 1/4" = 1'-0"
TECHNICAL NOTE 1 – EVALUATION AND INTERVENTION OF WOOD FRAME STRUCTURE:
ALL COMPONENTS OF THE WOOD FRAME BUILDING SHALL BE INDIVIDUALLY EVALUATED IN THE FIELD DURING
CONSTRUCTION. EACH STRUCTURAL ELEMENT SHALL BE INSPECTED FOR ITS CONDITION, STRUCTURAL
INTEGRITY, AND COMPLIANCE WITH THE APPROVED PLANS AND APPLICABLE CODES.
IF ANY DAMAGE, DETERIORATION, DECAY, BIOLOGICAL ATTACK, EXCESSIVE DEFORMATION, OR NON-
COMPLIANCE IS IDENTIFIED, THE AFFECTED COMPONENT SHALL BE REPLACED OR REINFORCED, AS
APPLICABLE, IN ACCORDANCE WITH SOUND ENGINEERING PRACTICES AND APPLICABLE STANDARDS.
THIS EVALUATION INCLUDES, BUT IS NOT LIMITED TO:
• STUDS;
• FLOOR JOISTS;
• ROOF RAFTERS;
• TOP PLATES AND BOTTOM PLATES;
• BEAMS, BRACING, AND ALL OTHER STRUCTURAL WOOD MEMBERS.
ALL REPLACEMENTS AND REINFORCEMENTS SHALL BE PERFORMED USING SUITABLE STRUCTURAL-GRADE
LUMBER, PRESSURE-TREATED WHERE REQUIRED, AND SHALL COMPLY WITH THE APPROVED STRUCTURAL
DESIGN DOCUMENTS.
GENERAL STRUCTURAL NOTE:
ALL STRUCTURAL CALCULATIONS FOR THIS PROJECT ARE
INCLUDED IN THE STRUCTURAL CALCULATION REPORT.
REFER TO THIS DOCUMENT FOR COMPLETE DESIGN
CRITERIA, LOAD ASSUMPTIONS, AND SIZING OF STRUCTURAL
ELEMENTS.
***FIELD CONDITIONS SHALL BE VERIFIED PRIOR TO
CONSTRUCTION. THIS DESIGN IS BASED ON ASSUMED
EXISTING CONDITIONS. IF ACTUAL FIELD CONDITIONS DIFFER
FROM THOSE ASSUMED, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE DESIGNER AND SHALL NOT
PROCEED WITH WORK IN THE AFFECTED AREA UNTIL
FURTHER INSTRUCTION IS PROVIDED.
GENERAL STRUCTURAL NOTE:
ALL STRUCTURAL CALCULATIONS FOR THIS PROJECT ARE
INCLUDED IN THE STRUCTURAL CALCULATION REPORT.
REFER TO THIS DOCUMENT FOR COMPLETE DESIGN
CRITERIA, LOAD ASSUMPTIONS, AND SIZING OF STRUCTURAL
ELEMENTS.
***FIELD CONDITIONS SHALL BE VERIFIED PRIOR TO
CONSTRUCTION. THIS DESIGN IS BASED ON ASSUMED
EXISTING CONDITIONS. IF ACTUAL FIELD CONDITIONS DIFFER
FROM THOSE ASSUMED, THE CONTRACTOR SHALL
IMMEDIATELY NOTIFY THE DESIGNER AND SHALL NOT
PROCEED WITH WORK IN THE AFFECTED AREA UNTIL
FURTHER INSTRUCTION IS PROVIDED.
NOTE: EXISTING FLOOR JOISTS – FIELD VERIFICATION
REQUIRED
ALL EXISTING FLOOR JOISTS SHALL BE FIELD VERIFIED UPON
OPENING OF THE FLOOR ASSEMBLY. IF ANY JOISTS ARE
FOUND TO BE DAMAGED, DETERIORATED, UNDERSIZED, OR
NOT IN COMPLIANCE WITH CURRENT CODE REQUIREMENTS
(IRC 2021 AND 780 CMR), THEY SHALL BE REPAIRED OR
REINFORCED AS REQUIRED.
TYPICAL CORRECTIVE MEASURES MAY INCLUDE SISTERING
JOISTS, REPLACING MEMBERS, OR INSTALLING NEW
STRUCTURAL ELEMENTS AS NEEDED. FINAL SIZING AND
REINFORCEMENT METHOD SHALL BE CONFIRMED BASED ON
ACTUAL FIELD CONDITIONS AND, IF REQUIRED,
COORDINATED WITH THE STRUCTURAL ENGINEER.
11'-1 1/2"
13'-10"
10'-6 1/2"
33'-0 1/2"
10'-8 1/2"
13'-8"
16'-3"
16'-8"
PROPOSED FLUSH BEAM: (3) 1-3/4" x 11-7/8" LVL BEAM
PROPOSED 6" X 6" POST WITH
ALIGNED THE BEAM
PROPOSED 6" X 6" POST WITH
ALIGNED THE BEAM
PROPOSED BEARING WALL
PROPOSED BEARING WALL
2x 8" CEILING JOISTS @ 16" O.C.
please, see the table R802.5.1 (2)
2x 8" CEILING JOISTS @ 16" O.C.
please, see the table R802.5.1 (2)
2x 8" CEILING JOISTS @ 16" O.C.
please, see the table R802.5.1 (2)
2x 8" CEILING JOISTS @ 16" O.C.
please, see the table R802.5.1 (2)
2x 8" CEILING JOISTS @ 16" O.C.
please, see the table R802.5.1 (2)
2x 8" CEILING JOISTS @ 16" O.C.
please, see the table R802.5.1 (2)
2x 8" CEILING JOISTS @ 16" O.C.
please, see the table R802.5.1 (2)
0505 0505 0505
0505
0505
0505
0505
0505
0505
0505
05050505
0505
0505
0505
0505
0505
0505
0505
0505
0505
0505
0505
NOTE – FLOOR FRAMING AT WALL:
FLOOR JOISTS SHALL BE ORIENTED PERPENDICULAR TO
AND BEAR ON TOP OF THE WALL. ON THE OPPOSITE SIDE,
THE USE OF A DROPPED BEAM MAY RESULT IN A
SIGNIFICANT STEP IN CEILING ELEVATION; COORDINATE
FRAMING TO MINIMIZE LEVEL DIFFERENCES AND MAINTAIN
A UNIFORM CEILING PROFILE WHERE POSSIBLE.
PROPOSED ATTIC LADDER
(2) 2x 8" CEILING JOISTS
(2) 2x 8" CEILING JOISTS
(2) 2x 8" CEILING JOISTS
FOA/AL
D-0
FOA/AL
D-0
19'
17'-2"
16'-11 1/2"
13'-7"
28'-4"
13'-1"
13'-3 1/2"
13'-8 1/2"
47'-4"
13'-2"
1 3 '-5 1 /2 "
9'-6"9'-6"
26'-8"
3'-7"
RIDGE BOARD 2"x12"
RIDGE BOARD 2"x12"
COLLAR TIE ON
EACH RAFTERS (2X6)
COLLAR TIE ON
EACH RAFTERS (2X6)
2X10" @16 O.C ROOF RAFTERS SEE
TABLE R802.4.1(5) RAFTERS SPANS
2X10" @16 O.C ROOF RAFTERS SEE
TABLE R802.4.1(5) RAFTERS SPANS
2X10" @16 O.C ROOF RAFTERS SEE
TABLE R802.4.1(5) RAFTERS SPANS
2X10" @16 O.C ROOF RAFTERS SEE
TABLE R802.4.1(5) RAFTERS SPANS
V A L L E Y S R A F T E R (2 ) 1 ½" × 1 1 ¼V
A
L
L
E
Y
S
R
A
F
T
E
R
(
2
)
1
½
"
×
1
1
¼
RD
D-0
RD
D-0
RD
D-0
RD
D-0
CT1/CT2
D-0
CT1/CT2
D-0
CT1/CT2
D-0
CT1/CT2
D-0
PROPOSED ROOF
PROPOSED ROOF
***BOTH ROOF SYSTEMS ARE NEW.
THE SMALLER ROOF IS LOCATED ABOVE AND
OVER THE MAIN ROOF AT A DIFFERENT
ELEVATION, CHARACTERIZING AN OVERLAY
CONDITION.
NO DIRECT FRAMING CONNECTION IS
INTENDED BETWEEN THE TWO ROOF SYSTEMS.
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-13
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED FRAME PLANS
PROPOSED ROOF FRAME PLAN
SCALE: 1/4" = 1'-0"
PROPOSED CEILING FRAME PLAN
SCALE: 1/4" = 1'-0"
FRAMING DETAILS:
RAFTERS SHALL BE FRAMED TO RIDGE BOARD OR TO EACH OTHER WITH A
GUSSET PLATE AS A TIE. RIDGE BOARD SHALL BE AT LEAST ONE-INCH
(25.4mm) NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT END
OF THE RAFTER. AT ALL VALLEYS AND HIPS THERE SHALL BE A VALLEY OR
HIP RAFTER NOT LESS THAN TWO-INCH (51mm) NOMINAL THICKNESS AND
NOT LESS IN DEPTH THAN THE CUT END OF THE RAFTER. HIP AND VALLEY
RAFTERS SHALL BE SUPPORTED AT THE RIDGE BY A BRACE TO A BEARING
PARTITION OR BE DESIGNED TO CARRY AND DISTRIBUTE THE SPECIFIC
LOAD AT THAT POINT. WHERE THE ROOF PITCH IS LESS THAN THREE UNITS
VERTICAL IN 12 UNITS HORIZONTAL (25% SLOPE), STRUCTURAL MEMBERS
THAT SUPPORT RAFTERS AND CEILING JOISTS, SUCH AS RIDGE BEAMS, HIPS
AND CEILING JOISTS, SUCH RIDGE BEAMS, HIPS AND VALLEYS, SHALL
BE DESIGNED AS
GENERAL STRUCTURAL NOTE:
ALL STRUCTURAL CALCULATIONS FOR THIS PROJECT ARE
INCLUDED IN THE STRUCTURAL CALCULATION REPORT.
REFER TO THIS DOCUMENT FOR COMPLETE DESIGN
CRITERIA, LOAD ASSUMPTIONS, AND SIZING OF STRUCTURAL
ELEMENTS.
GENERAL STRUCTURAL NOTE:
ALL STRUCTURAL CALCULATIONS FOR THIS
PROJECT ARE INCLUDED IN THE STRUCTURAL
CALCULATION REPORT. REFER TO THIS
DOCUMENT FOR COMPLETE DESIGN CRITERIA,
LOAD ASSUMPTIONS, AND SIZING OF
STRUCTURAL ELEMENTS.
EXISTING
DOOR
W04W04
EXISTING
DOOR
D02D02
W02W02
W01W01
EXISTING
WINDOW
W01W01
W03W03
W01W01
W07W07
7'
7'-5"
7'-5"
3'
3'
1'-7"
2'-10"
3'
2'-4"
5'-1"
7'-5"
3'3'
UTILITY &
PLAY AREA
SMOKE DETECTOR
BATH/
LAUNDRY
GARAGE
DINING KITCHEN BATH OFFICE
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
BATH
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
BATH
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
R. BEDROOMMASTER
BEDROOM
CONSTRUCTION CEILING:
· 1/2" GYPSUM BOARD (GWB);
· 1X3 WOOD STRAPPING · CEILING JOIST @ 16" O.C.;
· R-30 INSULATION BETWEEN JOISTS;
· VAPOR BARRIER (IF REQUIRED BY CLIMATE ZONE);
· CEILING FINISH
2X10" @16 O.C ROOF RAFTERS SEE
TABLE R802.4.1(5) RAFTERS SPANS
2 X 1 0 " @ 1 6 O .C R O O F R A F T E R S 2
X
10"
@
16 O.C R
O
O
F R
A
F
T
E
R
S
COLLAR TIE ON EACH
RAFTERS (2X6)
CT1/CT2
D-0
CT1/CT2
D-0
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
2x 8" CEILING JOISTS @ 16" O.C. 2x 8" CEILING JOISTS @ 16" O.C.
RIDGE BOARD 2" X 12"
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING SLAB-ON-GRADE TO REMAIN
EXISTING FLOOR JOIST TO REMAIN
EXISTING FLOOR JOIST TO REMAIN EXISTING FLOOR JOIST TO REMAIN
W2
D-0
W2
D-0
W2
D-0
W2
D-0
EXISTING EXTERIOR
WALL TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W1
D-0
W1
D-0
W1
D-0
W1
D-0
EXISTING
DOOR
W04W04
EXISTING
DOOR
D02D02
W02W02
W01W01
EXISTING
WINDOW
W01W01
W03W03
W01W01
W07W07
D02D02
EXISTING
DOOR
EXISTING
DOORWAY
D05D05D05D05D01D01
D01D01
W02W02
D01D01
W07W07
7'
7'-5"
7'-5"
3'
FAMILY
ROOM
SMOKE DETECTOR
ENTRY GARAGE
DINING KITCHEN CLOSET
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
HALL
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
R. BEDROOMMASTER
BEDROOM
CONSTRUCTION CEILING:
· 1/2" GYPSUM BOARD (GWB);
· 1X3 WOOD STRAPPING · CEILING JOIST @ 16" O.C.;
· R-30 INSULATION BETWEEN JOISTS;
· VAPOR BARRIER (IF REQUIRED BY CLIMATE ZONE);
· CEILING FINISH
2X10" @16 O.C ROOF RAFTERS SEE
TABLE R802.4.1(5) RAFTERS SPANS
2 X 1 0 " @ 1 6 O .C R O O F R A F T E R S 2
X
10"
@
16 O.C R
O
O
F R
A
F
T
E
R
S
COLLAR TIE ON EACH
RAFTERS (2X6)
CT1/CT2
D-0
CT1/CT2
D-0
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
2x 8" CEILING JOISTS @ 16" O.C. 2x 8" CEILING JOISTS @ 16" O.C.
STORAGE
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
HALL
COLLAR TIE ON EACH
RAFTERS (2X6)CT1/CT2
D-0
CT1/CT2
D-0
PROPOSED FLUSH BEAM:
(3) 1-3/4" x 11-7/8" LVL BEAM
SMOKE DETECTOR
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING SLAB-ON-GRADE TO REMAIN
EXISTING FLOOR JOIST TO REMAIN
W2
D-0
W2
D-0
PROPOSED 6" X 6" HSS STEEL POST
WITH ALIGNED FOUNDATION WALL
EXISTING EXTERIOR
WALL TO REMAIN
W2
D-0
W2
D-0
W1
D-0
W1
D-0
W1
D-0
W1
D-0
W2
D-0
W2
D-0
PROPOSED 6" X 6" HSS STEEL POST
WITH ALIGNED BEARING WALL
PROPOSED 6" X 6" POST WITH
ALIGNED FOUNDATION WALL
PROJECTION: PROPOSED 6" X 6" POST
WITH ALIGNED THE BEAM
PROPOSED FLUSH BEAM: STEEL BEAM W10×77
PROPOSED 3 1/2" Ø LALLY COLUMN WITH
24" x 24" x 12" FOOTING PAD W/ #5
HORIZONTAL BARS – TYP.
PROPOSED FOOTING PAD W/ #5
HORIZONTAL BARS – TYP.
EXISTING BEAM TO REMAIN. VERIFY IN FIELD (VIF) ITS EXISTENCE AND CONDITION. IF FOUND TO BE NONCOMPLIANT, CONTACT THE DESIGNER.
D02D02
EXISTING
DOOR
EXISTING
DOORWAY
D05D05D05D05D01D01
D01D01
W02W02
D01D01
W07W07
W03W03
W03W03
W07W07
7'-5"
7'
7'-5"
3'
7'
7'-5"
UTILITY &
PLAY AREA
SMOKE DETECTOR
FAMILY
ROOM
TOOL
ROOM
DININGLIVING FAN PLAY
ROOM
PROPOSED INTERIOR WALL:
- 2" x 6" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
T. OFFICE
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
WALK-IN CLOSETMASTER
BEDROOM
CONSTRUCTION CEILING:
· 1/2" GYPSUM BOARD (GWB);
· 1X3 WOOD STRAPPING · CEILING JOIST @ 16" O.C.;
· R-30 INSULATION BETWEEN JOISTS;
· VAPOR BARRIER (IF REQUIRED BY CLIMATE ZONE);
· CEILING FINISH
2X10" @16 O.C ROOF RAFTERS SEE
TABLE R802.4.1(5) RAFTERS SPANS
2 X 1 0 " @ 1 6 O .C R O O F R A F T E R S 2
X
10"
@
16 O.C R
O
O
F R
A
F
T
E
R
S
COLLAR TIE ON EACH
RAFTERS (2X6)
CT1/CT2
D-0
CT1/CT2
D-0
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
2x 8" CEILING JOISTS @ 16" O.C. 2x 8" CEILING JOISTS @ 16" O.C.
COLLAR TIE ON EACH
RAFTERS (2X6)CT1/CT2
D-0
CT1/CT2
D-0
SMOKE DETECTOR
2x 8" CEILING JOISTS @ 16" O.C.
PROPOSED FLUSH BEAM:
(3) 1-3/4" x 11-7/8" LVL BEAM
SMOKE DETECTOR
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
RIDGE BOARD 2" X 12"
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING SLAB-ON-GRADE TO REMAIN
EXISTING FLOOR JOIST TO REMAIN
EXISTING FLOOR JOIST TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
W2
D-0
W2
D-0
W2
D-0
W2
D-0
W1
D-0
W1
D-0
W1
D-0
W1
D-0
EXISTING BEARING
WALL TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
W1
D-0
W1
D-0
PROPOSED FLUSH BEAM:
STEEL BEAM W10×77
PROPOSED 6" X 6" HSS STEEL POST
WITH ALIGNED FOUNDATION WALL
PROJECTION: PROPOSED 6" X 6" POST WITH
ALIGNED FOUNDATION WALL
EXISTING EXTERIOR
WALL TO REMAIN
PROPOSED 3 1/2" Ø LALLY COLUMN WITH
24" x 24" x 12" FOOTING PAD W/ #5
HORIZONTAL BARS – TYP.
PROPOSED FOOTING PAD W/ #5
HORIZONTAL BARS – TYP.
EXISTING BEAM TO REMAIN. VERIFY IN FIELD (VIF) ITS
EXISTENCE AND CONDITION. IF FOUND TO BE
NONCOMPLIANT, CONTACT THE DESIGNER.
W03W03
W03W03
W07W07
EXISTING
DOOR
D06D06D01D01D06D06
W07W07
3'
7'-5"
7'-5"
ENTRYBATH/
LAUNDRY
HALLBATH PANTRY
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
BATH
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
PROPOSED EXTERIOR WALL:
- WEATHER-RESISTANT BARRIER OVER SHEATHING
- 1/2" CDX PLYWOOD SHEATHING
- 2x6 SPF #2 STUDS @ 16" OC
- CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS
EXTERIOR INSULATION
- 1/2" GYPSUM BOARD INTERIOR FINISH
OFFICE
CONSTRUCTION CEILING:
· 1/2" GYPSUM BOARD (GWB);
· 1X3 WOOD STRAPPING · CEILING JOIST @ 16" O.C.;
· R-30 INSULATION BETWEEN JOISTS;
· VAPOR BARRIER (IF REQUIRED BY CLIMATE ZONE);
· CEILING FINISH
2 X 1 0 " @ 1 6 O .C R O O F R A F T E R S 2
X
10"
@
16 O.C R
O
O
F R
A
F
T
E
R
S
COLLAR TIE ON EACH
RAFTERS (2X6)
CT1/CT2
D-0
CT1/CT2
D-0
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT
-ASPHALT SHINGLES OVER 1 LAYER OF APPROVED
UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX
PLYWOOD SHEATHING (IRC R803).
- 2"X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5).
- 2" x 12" RIDGE BOARD
- ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 –
MASSACHUSETTS).
- 1"X3" WOOD STRAPPING FOR CEILING SYSTEM.
- 1/2" GWB CEILING FINISH (IRC R702.3).
- ROOF PITCH 8:12.
2x 8" CEILING JOISTS @ 16" O.C.
SMOKE DETECTOR
SMOKE DETECTOR
SMOKE DETECTOR
HALL
PROPOSED INTERIOR WALL:
- 2" x 4" SPF #2 STUDS @ 16" OC
- CAVITY INSULATION: R-13 MIN
(WHERE REQUIRED)
- 1/2" GYPSUM BOARD (BOTH
SIDES)
PROPOSED BEARING
INTERIOR WALL:
- 2" x 6" SPF #2 STUDS
@ 16" OC
- CAVITY INSULATION:
R-13 MIN (WHERE
REQUIRED)
- 1/2" GYPSUM BOARD
(BOTH SIDES)
CLOSET
2x 8" CEILING JOISTS @ 16" O.C.
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING FOUNDATION
WALL TO REMAIN
EXISTING SLAB-ON-GRADE TO REMAIN
EXISTING FLOOR JOIST TO REMAIN
EXISTING FLOOR JOIST TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
EXISTING EXTERIOR
WALL TO REMAIN
W2
D-0
W2
D-0
W1
D-0
W1
D-0
W1
D-0
W1
D-0
ASSUMED BEARING
WALL – VERIFY IN FIELD
EXISTING EXTERIOR
WALL TO REMAIN
EXISTING POST
TO REMAIN
ASSUMED BEARING
WALL – VERIFY IN FIELD
W2
D-0
W2
D-0
EXISTING BEAM TO REMAIN. VERIFY IN FIELD (VIF) ITS
EXISTENCE AND CONDITION. IF FOUND TO BE
NONCOMPLIANT, CONTACT THE DESIGNER.
EXISTING
DOOR
D06D06D01D01D06D06
W07W07
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-14
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED CROSS SECTIONS
PROPOSED CROSS SECTION - S1
SCALE: 1/4" = 1'-0"
PROPOSED CROSS SECTION - S2
SCALE: 1/4" = 1'-0"
PROPOSED CROSS SECTION - S3
SCALE: 1/4" = 1'-0"
PROPOSED CROSS SECTION - S4
SCALE: 1/4" = 1'-0"
84"
24"
28"28"
30"
12"
56"
BATH/LAUNDRY
36"
36"
20 1/2"15"
BATH/LAUNDRY
36"
36"
89"
46"
21"15"
BATH
28"
61"
26"
26"
28"
24"
61"
24"
70"
32"
48"
C. OFFICE
89"
32"44"
36"
36"
14"
14"
16"
12"
14"
14"
PANTRY
36"
36"36"
44"
36"
PANTRY
36"
12 1/2"
36"26"12"34 1/2"
16"
72"
36"
34"
26"24"22"
19"
36"
44"
KITCHEN
36"
26"
26"
36"
19"
34"
24"18"28"12"
34"
19"
KITCHEN
36"
30"30"30"
34"
12"
36"
24"
19"
KITCHEN
36"
36"46"
89"
15"21"
BATH
36"
32"
20"
32"
89"
19"15"
MASTER BATH
89"
52"42"42"
21"
21"
23"29"
WALK-IN CLOSET
89"
28"
36"42 1/2"
44"
21"
22"
21"
24"
WALK-IN CLOSET
89"
42"42"
28"
24"
WALK-IN CLOSET
89"
42"36"36"
21"21"
21"
21"
WALK-IN CLOSET
28"
34"38"44"
61"
61"
34"44"
48"
48"
32"
T. OFFICE
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-15
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
PROPOSED INTERIOR ELEVATION - IE1
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE2
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE3
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE4
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE5
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE6
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATIONS
PROPOSED INTERIOR ELEVATION - IE7
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE8
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE9
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE10
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE11
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE12
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE13
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE14
SCALE: 1/4" = 1'-0"PROPOSED INTERIOR ELEVATION - IE15
SCALE: 1/4" = 1'-0"
PROPOSED INTERIOR ELEVATION - IE16
SCALE: 1/4" = 1'-0"
D3 - ATTACHING TO BUILDING (LEDGER DETAIL)
SB1 - STEEL BEAM CONNECT
For SI: 1 inch = 25.4 mm
RD - RIDGE DETAIL
06 - FOUNDATION CONNECTION
09 - TOP OF DECK STAIR-STRIGER ATTACH11 - LATERAL CONNECTOR
D1 - DECK DETAIL
THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY
SHEET:
SCALE:
DATE:
04/28/2026
A-16
PROJECT ADDRESS:
14 Gallows Hill Rd. -
Salem, MA
INDICATED
DETAILS
D-0
W1 - EXTERIOR WALL ASSEMBLY
SD - SOFFIT DETAIL
WF2 - FIRE RESISTANCE WALLW2 - INTERIOR WALL
CT1 - COLLAR TIE
DISTANCE X=2/3
THE RAFTER LENGTH
CT2 - COLLAR TIE
(1) LAYER 5/8'' GWB, PTD
CON'T VAPOR RETARDER
2X6 WOOD STUDS AT 16'' O.C.
CAVITY INSULATION R-20 MIN
1/2'' CDX PLWD SHEATHING
CON'T AIR AND WATER BARRIER
EXTERIOR SIDING
U-RATING: U-0.044 MAX
SIM UL U408
R-5 CONTINUOUS EXTERIOR
INSULATION
RL1 - CONNECTION TO BUILDING
MC - METAL CONNECTOR OPTIONS
FOR WOOD STRUCTURES
FL1 - FLOOR DETAIL
LF1 - LEDGER FASTENER SPACING
B1 - (BEAM DETAIL)
CONSTRUCTION FIRST FLOOR:
FLOOR ASSEMBLY: FLOOR FINISH
3/4" T&G PLYWOOD SUBFLOOR
JOIST @16" O.C. WITH R-30 INSULATION
AIR-SEALING OF THE FLOOR ASSEMBLY TO PREVENT
TEMPERATURE AND AIR TRANSFER
F2 - FOUNDATION CONNECTIONF1 - STEM WALL FOUNDATION
WITH SLAB-ON-GRADE
RD1 - RIDGE BOARD DETAIL
D5 - GUARD CONSTRUCTION
D2 - LATERAL CONNECTOR D4 - TOP OF DECKS STAIR-STRIGER ATTACH
E1 - (STAIR DETAIL)E2 - (STAIR DETAIL)E3 - STAIR BASE FOOTING