Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
11 DODGE STREET (HAMPTON INN) OUTLET COVER CERTIFICATE 7-21-2026
o� z w nPr 64 o M v c w (A 3 m cn OQ c 000 c O `t O A CA 4-.Z ( cn v K n x f - 0 n ° W 'C ry CCD 0 w `C T a O o -' `- O n o 3 CD o -o • o v o_ m, C O c a v o o O N Ch CD CD ••,fi M ro U) c t7 `D C o ram- to ' � N 00 ro0 ao C CD Ln� D � ISDUALSWG8 RevA HAYWARIY DUAL SUBMERGED SUCTION OUTLET SET and REPLACEMENT COVERS [Commonly called main drains] Owner's Manual InstallationContents For Models:WG1030,WG1048,WG1049,WG1051,WG1052,WG 1053,WG1054,WG1153,WG1154 Covers:WGX1048E,WGX1048EDGR,WGX1048EGR,WGX1048EBLK which are suitable for these models When installing and using this equipment basic safety precautions shall always be followed including the following: IMPORTANT SAFETY INSTRUCTIONS READ, FOLLOW AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS A This is the safety-alert symbol.When you see this symbol on your equipment or in this manual, look for one of the following signal words and be alert to the potential for personal injury. A WARNING warns about hazards that could cause serious personal injury, death or major property damage and if ignored presents a potential hazard. A CAUTION warns about hazards that will or can cause minor or moderate personal injury and/or property damage and if ignored presents a potential hazard. It can also make consumers aware of actions that are unpredictable and unsafe. Hayward Industries Inc. 400 Connell Drive Suite 61oo Berkeley Heights, N)07922 Phone: (908)355.7995 www.hayward-pool.com USE ONLY HAYWARD GENUINE REPLACEMENT PARTS f 0HAYWARD A WARNING - READ, FOLLOW AND UNDERSTAND ALL WARNINGS AND INSTRUCTIONS this owner's manual and on the equipment.Failure to follow instructions can cause severe injury and/or death. A WARNING —Suction Entrapment Hazard. Suction in suction outlets and/or suction outlet covers which are,damaged,broken,cracked,missing,or improperly secured can cause severe injury and/or death due to the following entrapment hazards: rrt Hair Entrapment-Hair can become entangled in suction outlet cover. Limb Entrapment-A limb inserted into an opening of a suction outlet sump or suction outlet coverthat is damaged,broken, cracked,missing,or not securely attached can result in a mechanical bind or swelling of the limb. Body Suction Entrapment-A negative pressure applied to a large portion of the body or limbs can result in an entrapment. Evisceration/Disembowelment-A negative pressure applied directly to the intestines through an unprotected suction outlet sump or suction outlet cover which is,damaged,broken,cracked,missing,or unsecured can result in evisceration/ disembowelment. Mechanical Entrapment-There is potential for jewelry,swimsuit,hair decorations,finger,toe or knuckle to be caught in an opening of a suction outlet cover resulting in mechanical entrapment. A WARNING -To Reduce the risk of Entrapment Hazards: o When outlets are small enough to be blocked by a person,a minimum of two functioning suction outlets per pump must be installed. Suction outlets in the same plane(i.e.floor or wall),must be installed a minimum of three feet(3') [i meter] apart,as measured from center to center. o Dual suction fittings installed closer than three feet center to center shall be located on two different lanes,i.e.one suction fitting assembly shall be on the pool floor,and one shall be located on a vertical wall,or one fitting shall be located on each of two separate walls. o Suction fittings shall not be located on seating areas or on the backrest for such seating areas. '1 o The maximum system flow rate shall not exceed the flow rating of as listed on Table i for the Branch piping. o The maximum specific flow rating of the Suction Outlet Assembly shall not be exceeded at any time the pool is open to bathers. o never use Pool or Spa if any suction outlet component is damaged,broken,cracked,missing,or not securely attached. o Replace damaged,broken,cracked,missing,or not securely attached suction outlet components immediately,before bathers are allowed to use the pool. o In addition to two or more suction outlets per pump which should be installed in accordance with latest ASME,APSP Standards and CPSC guidelines,all applicable National,State,and Local codes should be followed. o Installation of a vacuum release or vent system,which relieves entrapping suction,is recommended. o Only Hayward specified fasteners(screws)shall be used to secure the suction outlet cover. A WARN I NG —Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets can result in an increase potential for suction entrapment as described above. A WARN NG —Failure to keep suction outlet components clear of debris,such as leaves,dirt,hair,paper and other material can result in an increased potential for suction entrapment as described above. A WARNING —Suction outlet components have a finite life. The cover/grate and screws should be inspected frequently and replaced at least every seven years or if found to be damaged,broken,cracked,missing,or not securely attached.All other SOFA components should be inspected frequently and replaced at least every 28 years or if found to be damaged, broken,cracked.Service life begins in the month and year of installation. A CAUTION —Components such as the filtration system,pumps and heater must be positioned so as to prevent their being used as means of access to the pool by young children. To reduce risk of injury,do not permit children to use or climb on these products. Closely supervise children at all times. Components such as the filtration system,pumps,and heaters must be positioned to prevent children from using them as a means of access to the pool. A WARNING — Hazardous Pressure. Pool and spa water circulation systems operate under hazardous pressure during start up,normal operation,and after pump shut off. Stand clear of circulation system equipment during pump start up. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover,and/or filter housing and clamp due to pressure in the system,which could cause property damage,severe personal injury,or death. Before servicing pool and spa water circulation system,all system and pump controls must be in off position and filter manual air relief valve must be in the open position. Before starting system pump,all system valves must be set in a position to allow system water to return back to the pool. Do not change the filter control valve position while the system pump is running. Before starting the system pump,fully open filter manual air relief valve. Do not close filter manual air relief valve until a steady stream of water(not air or air and water) is discharged. A WARNING —Separation Hazard. Failure to follow safety and operation instructions could result in violent separation of pump and/or filter components. The strainer cover must be properly secured to pump housing with the strainer cover lock ring. Before servicing a pool and spa circulation system,the filter's manual air relief valve must be in the open position. Do not operate a pool and spa circulation system if a system component is not assembled properly,damaged,or missing. Do not operate pool and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body. Never operate or test the circulation system at more than 5o PSI. Do not purge the system with compressed air. Purging the system with compressed air can cause components to explode,with risk of severe injury or death to anyone nearby. Use only a low pressure(below 5 PSI),high volume blower when air purging the pump,filter,or piping. Any modification that increases the flow rate of the circulation system shall require re-evaluation of the cover/grate and sump to ensure that the flow rating of the Suction Outlet Fitting Assembly(SOFA) is not exceeded. Missing, broken,or cracked covers/grates,sumps,mud-frames,or any other SOFA component shall be replaced before bathers are allowed to use the pool. Loose cover/grates shall be reattached before bathers are allowed to use the pool. 7 L USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 0HAYWARKY ACCEPTABLE PIPE SIZE FOR MAXIMUM RECOMMENDED SYSTEM The Cover and Sump combination are rated at FLOW RATE PER APSP-7 the following Maximum Allowable Flow Rates (6 FT/SEC IN THE BRANCH LINE) Pipe Size Flow rate GPM Pipe Size Flow rate 2"Side Port Floor-Mounted 116GPM [mm] [LPM] [mm] GPM[Liter/Min] 2"Bottom Port Floor-Mounted 123GPM 1 12 (IO 2" (3 2"Side Port Wall-Mounted 66GPM 1/2 [150] L751 [2 3 2"Bottom Port Wall-Mounted 59 GPM 11/2"Side Port Floor-Mounted 107 GPM CHART 1 11/2"Side Port Wall-Mounted 72 GPM 11/2"Bottom Port Floor-Mounted 122 GPM The Head loss curves were measured in schedule 40 piping of the size 11/2"Bottom Portwa -Mounted 64GPM of the sump port,24 inches from the sump with the cover installed. Piping loss was accounted for on these curves. Chart 2 Head Loss Curves WG1048E on Sump =7-5 - 2'Side Port RECOMMENDED SYSTEM L 2 - -2"Bottom Port SPECIFICATIONS: 1.5 ---.I 1/2"Side Port 1 WG10 8E2,WG10 8E2GR WG10 8E2DGR and 0 o.s � � -••••• 11/2"Bottom Port 4 4 4 0 WG1048E2BLK Suction Outlet Covers are rated for the Floor 0 20 40 60 Bo 100 120 140 and the Wall per chart 2.The Suction Outlet Fitting Flow Rate in GPM assemblies that include the listed covers are considered "Blockable"by the latest APSP-16 standard. In new pools the Suction Outlet Assemblies shall be installed in multiples. In existing pools with a single"Blockable"Suction Outlet Assembly,the flow rating is the flow rating of the Suction Outlet Assembly,only when also installed in conjunction with an additional device or system designed and qualified to ASME 112.19.17 to prevent suction entrapment. A Suction Outlet Assembly in a system that does not also include one of the additional devices or systems shall result, in a flow rating of zero.The flow rating for pools with multiple blockable SOFAS in one body of water without isolation valves:combine all SOFAS minus the flow rate of one.If all are not equal,use the largest flow rate. The flow ratings of the Suction outlet Assemblies are performance based. These flow limits are designed to prevent suction entrapment. No field modifications shall be made to a Suction Outlet fitting structure or flow path. In the event of one suction outlet being blocked,the remaining suction outlets serving that system shall have a flow rating capable of the full flow of the pump(s)forthe specific suction system. Skimmers,gutters,and other outflow systems may not always be operational and could divert all the pump(s)flow through the Suction Outlet Fitting Assembly suction system,therefore the flow capacity of the Skimmers,gutters and other outflow systems shall not be Included when evaluating an individual suction system flow rating. Example: In the System shown in Diagram 1,two(2)suction outlet covers are selected and mounted on the floor with 2"piping on a WG1049 sump. These covers are individually rated for 122 GPM. The pump is rated at a maximum flow rate of 63 GPM. At the desired flow of 63 GPM one cover could be partially blocked and the other suction outlet flow would be below the rated 122 GPM of the"Floor" mounted suction outlet cover.Since there are two outlets flowing in normal operation,the same pipe size is recommended in the interconnecting piping. Example: In the System shown in Diagram 2,one(i)suction outlet cover mounted in the floor on a WGioi54 sump,rated at 123 GPM,and one(i)suction outlet cover mounted on the wall on a WG1154 sump with 2"piping,rated at 59 GPM. For a desired flow rate through the PUMP of 5o GPM,these are 2"sumps. At the desired flow of 5o GPM either cover could be totally blocked.The other suction outlet flow rate would be below the rated 59 GPM of the wall mounted suction outlet cover. Note:Flow maybe limited by entrapping force in dual suction systems. Minimum distance g reet Dual Outlets on Different Wanes (Pipe centerline) Flooroutlets (Elevation or Plan View) -44 wall Interconnecting • ti �PiDing Interconnecting Piping Floor System System Branch Piping Diagam a Branch piping `a l ftffnIR12 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 0HAYWARa INSTALLATION INSTRUCTIONS: -All SOFA's shall be installed according to these instructions. NOTICE: When installing WGi03oAVPAK2 refer to Fig i or Fig 2 below on the minimum dimensional requirements for construction of a field- fabricated sump to comply with the latest APSP-16 standard. The ring WG1058C must be securely attached to the pool structure,and flat to the pool finished surface. The WG1058C ring has been qualified for 11/2"and 2"piping only. Suction outlets for a pool with a vinyl liner or for fiberglass pools(WG1048AVPAK2 series for 1 1/2"pipe or WG1o49AVPAK2 series for 2" pipe)are provided with a WG1048B mounting ring and two(2)gaskets. The gaskets should be placed such that they sandwich the liner or fiberglass,that is,one gasket on each side. The ring(WG1048B)is attached to the suction outlet sump by eight(8)screws that pass through both gaskets and the liner. See diagram below. MOIL ossscxaws owaoYe � 5k' r+�-.__ 9�'!s covmro Y�mrnox 't' ;; -11. lr.� F omYEr. _ ....�, raua l � 1 m Suction outlets components and fastener receptacles must be free of dirt during installation. Field Fabricated Sumo Fie i Suction outlets WG1051AVPAK2 series for a concrete or gunite pools are designed to be plastered with the top surface flush to the pool surface. Suction Outlet Fitting Assemblies WGi153AVPAK2 series come with an Adjustable Collar to allow plasteringthe ring flush to - 5 g 53 the pool finished surface. Since both the WG10 6C ring and the WG11 B Collar are held ' in place by the interior finish of the pool,the finished surface shall be free of deterioration and voids.Those sumps not using the seal ring MUST use the long WGX103oZ1AM screw. Two machine screws(WGXi030Z2AM)or(WGX103oZiAM)MUST be used to secure the cover to the suction outlet fitting. The screws are designed to be started by hand to ensure proper thread engagement and to prevent cross threading. Finish assembling both screws by hand to a torque of 15 in*lb. Check by hand the snugness of the cover to the sump or frame after installation. DO NOT USE POWER TOOLS TO INSTALL FASTENERS. Unauthorized field modifications void the SOFA certification ' No modifications can be made to SOFA structure/flow without recertifying. If the sump cannot be identified as a Hayward sump,Hayward does not have an approved cover replacement Winterization: -�E Unless the suction outlet fitting is wall mounted and contains a manufactured sump,there is no need to winterize it. For wall mounted suction outlet fittings in areas where the Field Fabricated Sump Fig 2 piping is above the freeze line,it is recommended that the cover be removed,an air blower be utilized to remove the water in the line and a plug with an O-ring(SP1022C 11/2",SP1022C28LK 2")be installed to keep the water out of the pipe for the winter. A WARNING Suction Entrapment Hazard. Failure to remove Winterization plug can create I cova a Suction Entrapment Hazard that can cause severe injury and/or death.To avoid it is important to remove the winterizing plug before swimmers are allowed in the pool. Fastener/threaded insert repair or reinstallation: The integrity of the suction outlet fitting assembly relies on having the covers firmly attached to r the mating frame or sump. The screws that attach the cover must be inspected for thread damage,and/or corrosion,every time the cover is removed. If there is visible damage to the screws,they couwroa must be replaced,by pushing on,the end and unscrewing. Please be aware there are two lengths °BE of machine screws,they must be replaced by like screws from Hayward to assure proper attachment of the suction outlet cover. If the threaded inserts are damaged,or not installed in the sump they shall be removed and replaced through the use of the WG1048EKIT. Full instructions are included with the kit. NOTE: If self tapping screws are securing the suction outlet cover,the sump shall be replaced or modified to use the WG1048EKIT. A WARNING—Suction outlet components have a finite life,the cover/grate and screws should be inspected frequently and replaced at least every seven years,other components should be inspected frequently and replaced at least every 28 years. Components must be replaced if found to be damaged,by change in color,have brittle components with missing pieces,cracked,missing,or have stripped screw holes,not securely attached or no longer integral to the pool interior surface. The use of adhesives or other cover/grate attachment methods that prevent access to suction piping or SOFA components requiring servicing is prohibited. By design and per the latest APSP16 standard,covers when installed shall not protrude more than 2"from the finished surface of the pool. For installations utilizing a hydrostatic relief valve(SP1056),using a collectortube(SPi055)will maintain a clear path to the hydrostatic valve. At least one hydrostatic relief valve in a set of suction outlets will allow hydrostatic uplift pressure caused by ground water to be relieved into the pool or spa. 5 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS (07-) HAYWARD OPERATION: Each operational day the covers, including the fasteners, shall be observed for damage or tampering During installation of the cover and fasteners the Suction Outlet fitting assembly components, including the fasteners shall be clean and free of debris and/or obstructions. Replace damaged, broken,cracked, missing, or not securely attached suction outlet components, including fasteners and threaded inserts immediately. Loose cover/grates shall be reattached before bathers are allowed to use the pool. Since both the WG1056C ring and the WG11S3B Collar are held in place by the interior finish of the pool,the finished surface shall be free of deterioration and voids. SPARE PARTS LISTS ITEM SPARE PART DESCRIPTION QTY 1 WGXi03OZ2AM MACHINE SCREW SET i5/WLG i *WGX1048E WHITE COVER g .- *WGX1048EDGR DARK GRAY COVER 2 2 *WGX1048EGR GRAY COVER 1 "WGX1048EBLK BLACK COVER 3 _ t root WGX1048B WHITE RING a POOL 3 WGX1048BDGR DARK GRAY RINGLINER 1 WGX1048BGR GRAY RING _ WGX1048BBLK BLACK RING 4 SPX1048D GASKET 2 5 SPX1051Z1 1112 IN PLASTIC PIPE PLUG 1 5,6 6 SPX1053Z1 2 IN PLASTIC PIPE PLUG 1 7 SPX1039Z18 SCREW SET 1 NOTES: All color variations of WG1048AVPAK2/WG1049AVPAK2 have 1 1/2"NPT Plug for the bottom port. WG1048AVPAK2 / WG1049AVPAK2 *-SPARE COVER INCLUDES SCREWS FOR ALL VARIATIONS OF WG1048AVDGRPAK2 /WG1049AVDGRPAK2 SUMPS,WITH METAL INSERTS. For rings(WG1048B)without WG1048AVGRPAK2 /WG1049AVGRPAK2 metal inserts it is required that the rings be replaced to WGlo 8AVBLKPAK2 /WG10 AVBLKPAK2 Provide proper cover attachment utilizing new machine 4 49 screws during cover replacement. ' ITEM SPARE PART DESCRIPTION QTY 1 WGX103oZ1AM MACHINE SCREW SETT 1/4" 1.0 *WGX1o48E WHITE COVER *WGX1048EDGR DARK GRAY COVER �-� 2 *WGX1048EGR GRAY COVER i.o *WGXio 8EBLK BLACK COVER 3 SPX1051Z1 1112 IN PLASTIC PIPE PLUG i.o 4 SPX1053Z1 2 IN PLASTIC PIPE PLUG 1.0 _may NOTES: WG1051AVPAK2 /WGio52AVPAK2 have 11/2"NPT Plug fi r WG1053AVPAK2/WG10S4AVPAK2 have 2"NPT Plug •,� BODY ! =� J *-SPARE COVER INCLUDES SCREWS FOR ALL VARIATIONS OF SUMPS,WITH METAL INSERTS. For sumps without metal WG10 1AVPAK2/ WG10 2AVPAK2 inserts it is required that inserts be installed,following the S 5 instructions in the WG1048EKIT.This should provide proper WG1053AVPAK2/WG1054AVPAK2 cover attachment utilizing new machine screws during cover replacement. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 6 ITEM SPARE PART DESCRIPTION QTY F - 1 WGX303oZ1AM MACHINE 1.0 HAYWARD' *WGX1048E WHITE COVER 1 *WGX1048EDGR DARK GRAY COVER 2 1.0 1� *WGX1048EGR GRAYCOVER *WGX1048EBLK BLACK COVER WGX11S3B WHITE COLLAR WGXii53BDGR DARK GRAY COLLAR 3 1.0 WGX1153BGR GRAY COLLAR WGX1153BBLK BLACK COLLAR i 4 SPX1051Z1 11/2 IN PLASTIC PIPE 1.0 PLUG 5 SPX1053Z1 2 IN PLASTIC PIPE PLUG 1.0 " NOTES: �2- _ WG1153AVPAK2/WG1154AVPAK2 have 2"NPT Plug / WG2154SxxPAK2 has a 2"pipe socket as well as 2"NPT Plug BODY *-SPARE COVER INCLUDES SCREWS FOR ALL VARIATIONS OF SUMPS,WITH METAL INSERTS. For Collars without metal inserts it is required that inserts be installed,following the instructions in the WG1048EKIT,or the ring replaced.This should provide WG1153AVPAK2 / WG1154AVPAK2 proper cover attachment utilizing new machine screws during cover replacement. WG1154SPAK2 / WG1154SBLKPAK2 Since the WG1153B Collar is held in place by the interior finish of WG1154SDGRPAK2 / WG1154SGRPAK2 the pool,the finished surface shall be free of deterioration and voids. SEE NOTICE ON PAGE 5 FOR FIELD FABRICATED OUTLETS 1 ITEM SPARE PART DESCRIPTION QTY ! 1 — WGX103oZ1AM MACHINE SCREW SET11/4" 1.0 +N 2 *WGX1048E WHITE COVER *WGX1048EDGR DARK GRAY COVER 2 1.0 *WGX1048EGR GRAYCOVER *WGX1048EBLK BLACK COVER NOTES: *-SPARE COVER INCLUDES SCREWS FOR ALL VARIATIONS OF SUMPS,WITH OR WITHOUT METAL INSERTS.. For round frames without metal inserts it is required that inserts be installed,following the instructions in the WG1048EKIT or the ring replaced.This should provide proper cover attachment utilizing new machine screws during cover replacement. WG103oAVPAK2 /WG103oAVDGRPAK2 Since the WG1058C frame is held in place by the interior finish of the pool,the finished surface shall be free of WG103oAVGRPAK2 / WG103oAVBLKPAK2 deterioration and voids. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 7 i OHAYWAREY HAYWARD®LIMITED WARRANTY FTo Buyer,as original purchaser of this equipment,Hayward Industries Inc.400 Connell Drive Suite 61oo,Berkeley Heights,NJ, warrants its products free from defects in materials and workmanship for a period of ONE(i)year from the date of purchase. Parts which fail or become defective during the warranty period,except as a result of freezing,negligence,improper installation, use,or care,shall be repaired or replaced,at our option,without charge,within 90 days of the receipt of defective product, barring unforeseen delays. To obtain warranty replacements or repair,defective components or parts should be returned,transportation paid,to the place of purchase,orto the nearest authorized Hayward service center. For further Hayward dealer or service center information, contact Hayward customer service department. No returns may be made directly to the factory without the express written authorization of Hayward Pool Products. To original purchasers of this equipment,Hayward Pool Products warrants its products to be free from defects in materials and workmanship for a period of ONE(i)year from the date of purchase. Filters which become defective during the warranty period,except as a result of freezing,negligence,improper installation,use or care,shall be repaired or replaced,at our option,without charge.All other conditions and terms of the standard warranty apply. Hayward shall not be responsible for cartage,removal and/or reinstallation labor or any other such costs incurred in obtaining warranty replacements. The Hayward Pool Products warranty does not apply to components manufactured by others. For such products,the warranty established by the respective manufacturer will apply. Some states do not allow a limitation on how long an implied warranty lasts,or the exclusion or limitation of incidental or consequential damages,so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights,and you may also have other rights,which vary from state to state. Hayward Industries Inc. 400 Connell Drive Suite 61oo,Berkeley Heights,NJ 07922 Supersedes all previous publications. PRODUCT REGISTRATION (Retain For Your Records) DATE OF INSTALLATION Serial# _ Please place the date of installation on the"INSTALLATION INFORMATION LABEL"included with each cover. These labels shalt be permanently posted as near as feasible to the pump control. ♦Retain this Warranty Certificate(upper portion)in a safe and convenient location for your records. DETACH HERE:Fill out bottom portion completely and mail within io days of purchase/installation or register online. ------------------------------------------------------------------------------------------------------------------------------------- DUAL SUCTION OUTLET SET Warranty Card Registration Please Print Clearly: Years Pool has been in service First Name_ Last Name «year 1-3 4-5 6-io 11-15 >15 Street Address _ __ i Purchased from __ _ State Zip _ Builder Retailer Pool Service Internet/Catalog City Company Name_ Phone Number Purchase Date------ - Address E-Mail Address _ _—_ _ __ city State Zip Model Number Serial# Phone- Pool Capacity (U.S.Gallons) Type of Pool: Please include me on all e-mail communications regarding Hayward®Equipment or promotions. Concrete/Gunite Vinyl Fiberglass Mail to: Hayward Industries Inc. Attn:Warranty Dept, other 400 Connell Drive,Suite 61oo,Berkeley Heights, NJ 07922 New Installation Replacement Or REGISTER YOUR WARRANTY ON-LINE AT "AIW.HAYWARD-POOL.COM NMI Installation for:Hayward is a registered trademark of Hayward Industries,Inc. In Ground Above Ground Spa ©xozo Hayward Industries.Inc. USE ONLY HAYWARD GENUINE REPLACEMENT PARTS