Loading...
1BlockHouseSq-CofA-solar Salem Historical Commission 98 WASHINGTON STREET, SALEM, MASSACHUSETTS 01970 (978) 619-5685 CERTIFICATE OF APPROPRIATENESS It is hereby certified that the Salem Historical Commission has determined that the proposed: ✓ Construction  Moving  Reconstruction  Alteration  Demolition  Painting  Signage  Other work as described below will be appropriate to the preservation of said Historic District, as per the requirements set forth in the Historic District's Act (M.G.L. Ch. 40C) and the Salem Historic Districts Ordinance. District: Derby Street Address of Property: 1 Block House Square Name of Record Owner: Luz Villarreal Description of Approval of Work: ▪ Install roof solar array per attached plans with the following conditions: ▪ Solar panels to be aligned symmetrically as shown on attached marked-up image; ▪ All conduits to be placed on interior except for main conduit, which is to be located on Fort Avenue (north) elevation; ▪ Electric meter to remain in building interior; ▪ Associated electrical equipment for solar to be placed on Fort Avenue (north) elevation of building; ▪ Commission to be updated on contact with National Grid concerning meter location; ▪ Solar provider to submit an updated plan that incorporates conditions to Commission staff for review and final signoff before installation. Dated: August 5, 2026 SALEM HISTORICAL COMMISSION By: The homeowner has the option not to commence the work (unless it relates to resolving an outstanding violation). All work commenced must be completed within one year from this date unless otherwise indicated. THIS IS NOT A BUILDING PERMIT. All applicable building permits to be obtained prior to work commencing. Red circle – move panels to the right to symmetrical placement over dormer Move mechanical equipment to Fort Avenue/North elevation Keep electric meter in building interior COVER PAGE PROJECT INFO SOLAR PERMIT PACKAGE 12.040 KW GRID TIED PV SYSTEM SHEET SIZE 11" X 17" PROJECT # DATE DRAWN DRAWN BY SHEET # 0 7/2/26 AMES TITLE REV DESCRIPTION DATE NA M E : LU Z V I L L A R R E A L AD D R E S S : 1 B L O C K H O U S E S Q U A R E SA L E M MA 0 1 9 7 0 PV - CONTRACTOR INFO SOLGRID SOLAR SOLGRID INC 45 DAN RD CANTON MA 92021 design@solgridsolar.com 1 GENERAL NOTES: • THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE CONSTRUCTION PHASE. • JOB SAFETY AND CONSTRUCTION PROCEDURES ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. • REFER TO ELECTRICAL DRAWING PV-4 FOR PANEL DETAILED INFORMATION. • IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. • THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING INFORMATION SHOWN (DIMENSIONS, ROOFTOP PROJECTIONS, ETC.) AND NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATION OF THE PV SYSTEM. • THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING OPENINGS, ROOFTOP UNITS, VENT PIPES, ETC., SHOWN ON DRAWINGS. IF THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE CONTRACTOR’S/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER PRIOR TO PERFORMING THE WORK. • ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH ALL APPLICABLE TOWN, COUNTY, & STATE REGULATIONS AND/OR ANY OTHER GOVERNING BODIES. • DO NOT SCALE THESE DRAWINGS. USE DIMENSIONS. CONTRACTOR MUST CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR TO INSTALLATION. IF THERE IS A DISCREPANCY, IT IS THE CONTRACTOR'S/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER IMMEDIATELY. • LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS DOORS OR WINDOWS. ELECTRICAL NOTES: • ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR ITS APPLICATION. • ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V, 90°C & 75°C WET ENVIRONMENT. • WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE NEAREST RIDGE, HIP, OR VALLEY. • WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL EQUIPMENT SHALL COMPLY WITH CEC 110.26. • DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS, AND ACCESSORIES TO FULFILL APPLICABLE CODES AND STANDARDS. • WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. • ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND READILY VISIBLE. CODE INFORMATION: 2021 INTERNATIONAL BUILDING CODE 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL EXISTING BUILDING CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 INTERNATIONAL ENERGY CONSERVATION CODE 2021 INTERNATIONAL FIRE CODE 2023 NATIONAL ELECTRICAL CODE PV SYSTEM SUMMARY: (N) 28 - Q.TRON BLK M-G2.H+ (430W) - MODULES (N) 28 - ENPHASE IQ8HC-72-M-DOM-US - MICRO-INVERTERS (N) JUNCTION BOX (E) 125A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER (N) 60A FUSIBLE AC DISCONNECT (N) ENPHASE IQ COMBINER BOX 5 DESIGN CRITERIA: ROOF TYPE: SHINGLE FRAME: 2"X8" RAFTERS @ 16" O.C. STORY: TWO STORIES SNOW LOAD: 50 WIND SPEED: 119 MPH WIND EXPOSURE: C RISK CATEGORY: II COORDINATE: 42.52621, -70.88026 PHOTOVOLTAIC ROOF MOUNT SYSTEM LUZ VILLARREAL 1 BLOCK HOUSE SQUARE SALEM MA 01970 28 MODULES-ROOF MOUNTED - 12.040 kWDC SHEET INDEX VICINITY VIEW AERIAL VIEW COVER PAGE SITE PLAN ROOF PLAN STRUCTURAL ELECTRICAL SLD LABELS MICROINVERTER CHART SPEC. SHEETS PV-1.0 PV-2.0 PV-3.0 PV-4.0 PV-5.0 PV-6.0 PV-7.0 PV-8.0+ STRUCTURAL ONLY 07/09/2026 JB MSPUM ACD CB 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 18" F I R E P A T H W A Y 18" F I R E P A T H W A Y EXISTING DRIVEWAY N SITE PLAN PROJECT INFO SOLAR PERMIT PACKAGE 12.040 KW GRID TIED PV SYSTEM SHEET SIZE 11" X 17" PROJECT # DATE DRAWN DRAWN BY SHEET # 0 7/2/26 AMES TITLE REV DESCRIPTION DATE NA M E : LU Z V I L L A R R E A L AD D R E S S : 1 B L O C K H O U S E S Q U A R E SA L E M MA 0 1 9 7 0 PV - CONTRACTOR INFO SOLGRID SOLAR SOLGRID INC 45 DAN RD CANTON MA 92021 design@solgridsolar.com 2 SITE PLAN SCALE: 1/16" = 1'-0"1 NOTE: * 3/4" OR GREATER IMC, RMC, FMC, LFMC, PVC, HDPE, NUCC, RTRC, LFNC, FMT, ENT OR EMT CONDUIT RUN EXPOSED CONDUIT RUN SHALL BE MIN. 7/8" ABOVE ROOF. * ROMEX RUN INSIDE ATTIC ALL ELECTRICAL EQUIPMENT, INVERTERS, DISCONNECTS, MAIN SERVICE PANELS, ETC. SHALL NOT BE INSTALLED WITHIN 3' OF THE GAS METERS’ SUPPLY OR DEMAND PIPING. LEGEND (E) UTILITY METER (E) MAIN SERVICE PANEL (N) AC DISCONNECT (N) IQ COMBINER BOX 5 (N) JUNCTIONS BOX SETBACK CONDUIT MICROINVERTERS UM MSP ACD CB JB MODULE TYPE, DIMENSIONS & WEIGHT: NUMBER OF MODULES = 28 MODULE TYPE = Q.TRON BLK M-G2.H+ (430W) MODULE WEIGHT = 46.7 LBS. MODULE DIMENSIONS = 5.64' X 3.72' = 20.98 SF UNIT WEIGHT OF ARRAY = 2.23 PSF 5.64' 3.72' PHOTOVOLTAIC SOLAR MODULE Q.TRON BLK M-G2.H+ (430W) ROOF ACCESS POINT SHALL BE LOCATED IN AREAS THAT DO NOT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. (N) ENPHASE IQ COMBINER BOX 5(N) AC DISCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL ROOF 2 CONDUIT TO BE RUN ON THE WALL (N) JUNCTION BOX (N) ENPHASE IQ8HC-72-M-DOM-US MICRO-INVERTERS ARRAY AREA & ROOF AREA CALC'S TOTAL ARRAY AREA SQ.FT 587.46 TOTAL ROOF AREA SQ.FT TOTAL ROOF AREA COVERED BY ARRAY (%) 18.59 %3160.47 18.59 % (AREA OF ARRAY< 33% OF ROOF AREA) ROOF 1 ROOF 3 ROOF 4 FRONT YARD REAR YARD BLOCK HOUSE SQUARE (N) 3/4" OR GREATER EMT CONDUIT RUN (7/8 INCHES ABOVE ROOF) STRUCTURAL ONLY 07/09/2026 JB MSPUM ACD CB 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 1 8 " F I R E P A T H W A Y 18" F I R E P A T H W A Y 18" F I R E P A T H W A Y N PROJECT INFO SOLAR PERMIT PACKAGE 12.040 KW GRID TIED PV SYSTEM SHEET SIZE 11" X 17" PROJECT # DATE DRAWN DRAWN BY SHEET # 0 7/2/26 AMES TITLE REV DESCRIPTION DATE NA M E : LU Z V I L L A R R E A L AD D R E S S : 1 B L O C K H O U S E S Q U A R E SA L E M MA 0 1 9 7 0 PV - CONTRACTOR INFO SOLGRID SOLAR SOLGRID INC 45 DAN RD CANTON MA 92021 design@solgridsolar.com 3 ROOF PLAN SCALE: 1/16" = 1'-0"1 LEGEND (E) UTILITY METER (E) MAIN SERVICE PANEL (N) AC DISCONNECT (N) IQ COMBINER BOX 5 (N) JUNCTIONS BOX SETBACK CONDUIT RAFTERS ATTACHMENT RAILS UM MSP ACD CB JB 5.64' 3.72' ARRAY AREA & ROOF AREA CALC'S TOTAL ARRAY AREA SQ.FT 587.46 TOTAL ROOF AREA SQ.FT TOTAL ROOF AREA COVERED BY ARRAY (%) 18.59 %3160.47 18.59 % (AREA OF ARRAY< 33% OF ROOF AREA) PHOTOVOLTAIC SOLAR MODULE Q.TRON BLK M-G2.H+ (430W) ROOF MODULES ARRAY AREA ROOF AREA ROOF AREA COVERD BY ARRAY % SHINGLEROOF TYPE ROOF DESCRIPTION ROOF 1: 14 MODULES AZIMUTH: 134.42° PITCH: 35.00° (N) Q.TRON BLK M-G2.H+ (430W) MODULES ROOF PLAN ROOF 2: 2 MODULES AZIMUTH: 44.42°; PITCH: 36.00° ROOF 3: 6 MODULES AZIMUTH: 314.42°; PITCH: 36.00° ROOF 4: 6 MODULES AZIMUTH: 224.42°; PITCH: 36.00° MAX SPACING BETWEEN TWO ATTACHMENTS: 48" #1 14 293.73 664.93 44.17% #2 2 41.96 427.78 6.31% #3 6 125.88 618.35 18.93% #4 6 125.88 423.48 18.93% (N) ENPHASE IQ COMBINER BOX 5(N) AC DISCONNECT (E) UTILITY METER (E) MAIN SERVICE PANEL CONDUIT TO BE RUN ON THE WALL (N) JUNCTION BOX (N) 3/4" OR GREATER EMT CONDUIT RUN (7/8 INCHES ABOVE ROOF) STRUCTURAL ONLY 07/09/2026 PROJECT INFO SOLAR PERMIT PACKAGE 12.040 KW GRID TIED PV SYSTEM SHEET SIZE 11" X 17" PROJECT # DATE DRAWN DRAWN BY SHEET # 0 7/2/26 AMES TITLE REV DESCRIPTION DATE NA M E : LU Z V I L L A R R E A L AD D R E S S : 1 B L O C K H O U S E S Q U A R E SA L E M MA 0 1 9 7 0 PV - CONTRACTOR INFO SOLGRID SOLAR SOLGRID INC 45 DAN RD CANTON MA 92021 design@solgridsolar.com 4 STRUCTURAL B 7.0 1" F 7.0 D 7.0 C 7.0 36.00° IRONRIDGE RAIL QUICKMOUNT HUG H 7.4 J 7.4 PV MODULE FRAME IRONRIDGE UNIVERSAL FASTENING OBJECT 38" PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE UNIVERSAL FASTENING OBJECT PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE END IRONRIDGE RAIL 1"FASTENING OBJECT PV MODULE L REFERENCE CERT LETTER GUIDELINES E 7.0 G 7.0 J 7.4 IRONRIDGE UNIVERSAL FASTENING OBJECT IRONRIDGE END QUICKMOUNT HUG FASTENING OBJECT 1" PV MODULE FRAME IRONRIDGE RAIL IRONRIDGE END FASTENING OBJECT 1" Scale: 1"=1'-0"A PLAN VIEW, HUG RAFTER, PORTRAIT MODULE Scale: 1"=1'-0"B SIDE VIEW, HUG RAFTER, PORTRAIT MODULE Scale: 6"=1'-0"F DETAIL, END CLAMP (EFO) PLAN Scale: 6"=1'-0"G DETAIL, END CLAMP (EFO) FRONT Scale: 6"=1'-0"D DETAIL, MID CLAMP PLAN Scale: 6"=1'-0"E DETAIL, MID CLAMP FRONT Scale: 1"=1'-0"C FRONT VIEW, HUG RAFTER, PORTRAIT MODULE STRUCTURAL ONLY 07/09/2026 M L (E) 100A (N) LINESIDE TAP VIA LISTED CONNECTORS (N) GROUNDING WIRE #6 BARE COPPER 120V/240V, 60Hz 1-PHASE, 3-W, UTILTY METER METER NO# 12653524 (E) 125A MAIN SERVICE PANEL WITH (E) 100A MAIN BREAKER (E) 100A MAIN BREAKER C POWER LINE COMMUNICATION G INV(N) 10 - Q.TRON BLK M-G2.H+ (430W) MODULES STRING 1 (N) 10 - ENPHASE IQ8HC-72-M-DOM-US MICRO-INVERTRS JUNCTION BOX (2) Q-CABLE (1) PV #6 BARE CU GND (N) 20A (N) 20A (N) 20A (N) 15A (N) ENPHASE IQ GATWAY (N) ENPHASE IQ COMBINER BOX 5 G INV(N) 9 - Q.TRON BLK M-G2.H+ (430W) MODULES STRING 2 (N) 9 - ENPHASE IQ8HC-72-M-DOM-US MICRO-INVERTRS INV(N) 9 - Q.TRON BLK M-G2.H+ (430W) MODULES STRING 3 (N) 9 - ENPHASE IQ8HC-72-M-DOM-US MICRO-INVERTRS A G WIRE SCHEDULE WIRE TAG CONDUIT WIRE QTY WIRE GUAGE WIRE TYPE TEMP. RATING WIRE AMPACITY TEMP. DERATE CONDUIT FILL DERATE DERATED AMPACITY INVERTER QTY NOC CEC CORRECTION DESIGN CURRENT GROUND SIZE GROUND WIRE TYPE A MIN 3/4" EMT/PVC 6 THWN-2 90°40 0.91 0.8 29.12 10 1.58 1.25 19.75 10 AWG THWN-2 B MIN 3/4" EMT/PVC 3 THWN 75°65 0.88 1.0 57.20 28 1.58 1.25 55.30 6 AWG THWN C -- 6 AWG 10 AWG MIN 3/4" EMT/PVC 3 THWN 75°65 0.88 1.0 57.20 28 1.58 1.25 55.306 AWG (N) 60A FUSED VISIBLE- BLADE AC DISCONNECT WITH 60A FUSES B G N NEUTRAL TO GROUND BOUNDING PROJECT INFO SOLAR PERMIT PACKAGE 12.040 KW GRID TIED PV SYSTEM SHEET SIZE 11" X 17" PROJECT # DATE DRAWN DRAWN BY SHEET # 0 7/2/26 AMES TITLE REV DESCRIPTION DATE NA M E : LU Z V I L L A R R E A L AD D R E S S : 1 B L O C K H O U S E S Q U A R E SA L E M MA 0 1 9 7 0 PV - CONTRACTOR INFO SOLGRID SOLAR SOLGRID INC 45 DAN RD CANTON MA 92021 design@solgridsolar.com 5 LINE DIAGRAM NOTE: CONDUIT AND CONDUCTORS SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. ALL CONDUCTORS NOT UNDER ARRAY ARE TO BE IN CONDUIT MINIMUM 7/8" ABOVE ROOF WITH PROPER JUNCTION BOX AT EACH END PER 690.31A SYSTEM SPECIFICATIONS: SYSTEM TYPE: GRID-TIED MOUNTING METHOD: ROOF MOUNT MODULES: Q.TRON BLK M-G2.H+ (430W) INVERTERS: ENPHASE IQ8HC-72-M-DOM-US _380 VA TOTAL DC SYSTEM SIZE: 12.040 KW TOTAL AC SYSTEM SIZE: 10.640 KVA NUMBER OF MODULES: 28 NUMBER OF MICRO-INVERTERS: 28 SINGLE LINE DIAGRAM1 MANUFACTURER & MODEL NO. ENPHASE IQ8HC-72-M-DOM-US INVERTER SPECIFICATION MAX DC VOLT RATING 60V MAX POWER AT 240W 380W NOMINAL AC VOLTAGE 240V MAX AC CURRENT 1.58A MAX EFFICIENCY 97.3% MANUFACTURER & MODEL NO. Q.TRON BLK M-G2.H+ (430W) MODULE SPECIFICATION VOC 39.32V VMP 32.94V ISC 13.74A IMP 13.05A STC RATING 430W SERVICE FEED: OVERHEAD NOTE: ALL CONSTRUCTION NEEDS TO ABIDE BY THE ESB 750 & ESB 756. INSTALLATIONS CANNOT INCLUDE ANY KIND OF TAPS, METER COLLARS, OR ADAPTERS INSIDE NATIONAL GRID OWNED AND MAINTAINED EQUIPMENT, METER SOCKETS, METER CABINETS, OR ANYWHERE THERE ARE UN-METERED CONDUCTORS. ANY NEW METERING AND DISCONNECT EQUIPMENT WILL NEED TO BE GROUPED, POTENTIALLY LOCATED OUTSIDE AND 24/7 LOCKABLE AND ACCESSIBLE, IN ACCORDANCE WITH ESB 7.1.1. ALL EQUIPMENT LOCATIONS WILL NEED TO BE APPROVED BY NATIONAL GRID METERING DEPARTMENT PRIOR TO INSTALLATION. 07/09/2026 Proposed New Electrical Only PROJECT INFO SOLAR PERMIT PACKAGE 12.040 KW GRID TIED PV SYSTEM SHEET SIZE 11" X 17" PROJECT # DATE DRAWN DRAWN BY SHEET # 0 7/2/26 AMES TITLE REV DESCRIPTION DATE NA M E : LU Z V I L L A R R E A L AD D R E S S : 1 B L O C K H O U S E S Q U A R E SA L E M MA 0 1 9 7 0 PV - CONTRACTOR INFO SOLGRID SOLAR SOLGRID INC 45 DAN RD CANTON MA 92021 design@solgridsolar.com 6 LABEL 240 PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OPERATING CURRENT AMPS AC NOMINAL OPERATING VOLTAGE VOLTS 55.30A IN CASE OF EMERGENCY CALL SOLGRID INC 617-704-3400LABEL LOCATION: AC DISCONNECT(S), PHOTOVOLTAIC SYSTEM POINT OF INTERCONNECTION. PER CODE(S): NEC 2022: 690.54 LABEL LOCATION: SERVICE PANEL IF SUM OF BREAKERS EXCEEDS PANEL RATING NEC 705.12 (B)(3)(4) LABEL LOCATION: UTILITY SERVICE ENTRANCE/METER (WITHIN 3 FEET), INVERTER/DC DISCONNECT IF REQUIRED BY LOCAL AHJ, OR OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. PER CODE(S): NEC 2022: 690.56(C)(2) 1.NEC ARTICLES 690 AND 705 AND NEC SECTION R324 MARKINGS SHOWN HEREON. 2.ALL MARKING SHALL CONSIST OF THE FOLLOWING: A.UV RESISTANT SIGN MATERIAL WITH ENGRAVED OR MACHINE PRINTED LETTERS OR ELECTRO-PLATING. B.RED BACKGROUND COLOR WHITE TEXT AND LINE WORK. C.AERIAL FONT. 3. ALL SIGNS SHALL BE SIZED APPROPRIATELY AND PLACED IN THE LOCATIONS SPECIFIED. SIGNAGE CANNOT BE HAND-WRITTEN. 4. SIGNS SHALL BE ATTACHED TO THE SERVICE EQUIPMENT WITH POP-RIVETS OR SCREWS. LABEL LOCATION: POINTS OF CONNECTION/BREAKER CODE: NEC 705.12(B)(3)(3) LABEL LOCATION: AC DISCONNECT NEC 690.13(B) LABEL LOCATION: MAIN PANEL (IF APPLICABLE). PER CODE(S): NEC 2022: NEC 706.15 (C)(4) & NEC 690.13(B) ! WARNING THIS EQUIPMENT FED BY MULTIPLE SOURCES TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR RAPID SHUTDOWN SWITCH FOR SOLAR SYSTEM PV SYSTEM DISCONNECT POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE ! WARNING ELECTRICAL SHOCK HAZARD TERMINALS ON LINE AND LOAD SIDES MAYBE ENERGIZED IN THE OPEN POSITION ! WARNING PLACARD LOCATION: MAIN SERVICE DISCONNECT / UTILITY METER (PER CODE: NEC 690.13(B)) MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: EMT/CONDUIT RACEWAYS (PER CODE: NEC690.31(D)(2) PHOTOVOLTAIC POWER SOURCE DUAL POWER SOURCE SECOND SOURCE IS PHOTOVIOLTAIC SYSTEM ! WARNING LABEL LOCATION: POINT OF INTERCONNECTION PRODUCTION METER NEC 705.12(B)(3)(3) & NEC 690.59) SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS SECTION OF THE PV SYSTEM THAT ARE NOT SHUTDOWN WHEN RAPID SHUTDOWN SWITCH IS OPERATED TURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SECTION OF THE PV SYSTEM THAT ARE SHUTDOWN WHEN RAPID SHUTDOWN SWITCH IS OPERATED SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS SECTION OF THE PV SYSTEM THAT ARE NOT SHUTDOWN WHEN RAPID SHUTDOWN SWITCH IS OPERATED TURN RAPID SHUTDOWNSWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY SECTION OF THE PV SYSTEM THAT ARE SHUTDOWN WHEN RAPID SHUTDOWN SWITCH IS OPERATED 07/09/2026 Proposed New Electrical Only N PROJECT INFO SOLAR PERMIT PACKAGE 12.040 KW GRID TIED PV SYSTEM SHEET SIZE 11" X 17" PROJECT # DATE DRAWN DRAWN BY SHEET # 0 7/2/26 AMES TITLE REV DESCRIPTION DATE NA M E : LU Z V I L L A R R E A L AD D R E S S : 1 B L O C K H O U S E S Q U A R E SA L E M MA 0 1 9 7 0 PV - CONTRACTOR INFO SOLGRID SOLAR SOLGRID INC 45 DAN RD CANTON MA 92021 design@solgridsolar.com 7 MICROINVERTER CHART MICROINVERTER CHARTSTICKERS 1# 2# 3# 4# 5# 6# 7# 8# 9# 10# 11# 12# 13# 14# 15# 16# 17# SR NO#SR NO#STICKERS MICROINVERTER CHART 19# 20# 21# 22# 23# 24# 25# 26# 27# 28# 29# 30# 31# 32# 33# 34# 18# 35# 36# 37# 38# 39# 40# 41# 42# 43# 44# 45# 46# 47# 48# 49# 50# 51# 52# 54# 55# 56# 57# 58# 59# 60# 61# 62# 63# 64# 65# 66# 67# 68# 69# 53# 70#