Elevation and Floor PlanNO SCALE GENERAL NOTES: DRAWINGS ARE REPRESENTATIVE DOCUMENTS TO FACILITATE CONSTRUCTION. CONTRACTOR SHOULD FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. THE HEIGHTS OF GRADE INDICATED ON THE DRAWINGS ARE APPROXIMATE AND ARE PROVIDED FOR INFORMATION ONLY. THE ACTUAL GRADE ELEVATIONS SHOULD BE IDENTIFIED IN A SITE PLANS BY A REGISTERED LAND SURVEYOR. NOTIFY DESIGNER OF ANY ALTERATIONS OR DISCREPANCIES BEFORE PROCEEDING WITH WORK AND IMMEDIATELY UPON DISCOVERY. SECTIONS AND DETAILS SHOWN, WHILE DRAWN FOR SPECIFIC LOCATIONS ARE INTENDED TO ESTABLISH THE GENERAL TYPES OF DETAILS TO BE USED THROUGHOUT. WORK NOT INDICATED ON A PART OF THE DRAWINGS BUT REASONABLY IMPLIED TO BE SIMILAR TO THAT SHOWN AT CORRESPONDING PLACES, SHALL BE REPEATED. SHOULD THE CONTRACTOR AND/OR OWNER DESIRE ANY ALTERATIONS TO THIS SET OF PLANS, OR IF ANY DISCREPANCIES OR OMISSIONS ARE IDENTIFIED, THE SAME MUST BE PRESENTED/ COMMUNICATED IN WRITING IMMEDIATELY. UNDER NO CIRCUMSTANCE SHALL THE WORK CONTINUE UNTIL A REASONABLE SOLUTION IS AGREED UPON BETWEEN ALL STAKEHOLDERS. CONTRACTOR TO VERIFY AND/OR ESTABLISH ALL EXISTING CONDITIONS AND DIMENSIONS AT THE SITE AND TO NOTIFY OWNER/DESIGNER OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM DRAWINGS. PROPOSED REMEDIES, IF REQUIRING ADDITIONAL WORK, ARE TO BE SUBMITTED FOR APPROVAL IN THE FORM OF WRITTEN CHANGE ORDERS TO THE OWNER IN ACCORDANCE WITH THE TERMS OF THE CONTRACT BEFORE ORDERING MATERIAL OR COMMENCING WITH WORK. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DRAWINGS SHALL NOT BE SCALED BY HAND. USE ONLY PRINTED DIMENSIONS TO IDENTIFY SIZE AND DIMENSION OF MATERIALS AS SHOWN. CONTACT THE DESIGNER TO VERIFY ANY DIMENSION THAT HAS BEEN OMITTED FROM THESE PLANS. CONTRACTOR AND SUB-CONTRACTORS SHALL PERFORM ALL CUTTING AND PATCHING REQUIRED TO COMPLETE WORK, OR MAKE PARTS FIT TOGETHER PROPERLY WITHOUT COMPROMISING QUALITY OF WORK. MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEM ARE INDICATED ON ARCHITECTURAL DRAWINGS FOR COORDINATION ONLY. BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. ALL NAILS AND FASTENERS IN AREAS PRONE TO MOISTURE SHALL BE "HOT DIPPED GALVANIZED" UNLESS OTHERWISE NOTED. THE CONTRACTOR AND SUBCONTRACTORS SHALL KEEP SUFFICIENT WORKMEN ON THE JOB SITE AT ALL TIMES TO PERFORM WORK IN THE MOST EXPEDITIOUS MANNER CONSISTENT WITH GOOD WORKMANSHIP, SOUND BUSINESS PRACTICE AND IN THE BEST INTEREST OF THE OWNER. INCOMPETENT WORKERS WILL NOT BE RETAINED ON THE JOBSITE. FIRE SAFETY: STORE ALL CONSTRUCTION MATERIALS IN A SECURE AND LOCKED AREA CONTROLLED BY THE CONTRACTOR. AT NO TIME DURING THE WORK SHALL STORED MATERIALS OR TOOLS BLOCK OR IMPEDE A PATH OF EMERGENCY MEANS OF EGRESS. DO NOT ALTER OR NEGATE THE FIRE-RATING OF EXISTING CONSTRUCTION TO REMAIN. MAINTAIN FULL AND PROPER OPERATION OF THE BUILDING FIRE ALARM SYSTEM FOR THE DURATION OF THE WORK. PROVIDE FIRESAFING AT ALL PENETRATIONS MADE THROUGH NEW AND ETR FIRE-RATED CONSTRUCTION TO PROVIDE/MAINTAIN REQUIRED FIRE SEPARATION RATING. PROJECT INFORMATION SHEET, NOTES AND LEGENDS PROJECT ADDRESS: 17 LINCOLN RD. - SALEM, MA ADU ADDITION - RESIDENTIAL - 563 sqft LICENSES: PLUMBING, FIRE PROTECTION, ELECTRICAL AND TELEDATA WORK SHALL BE PERFORMED BY QUALIFIED, EXPERIENCED PERSONS CURRENTLY LICENSED IN THEIR RESPECTIVE TRADE. WORK HOURS: COORDINATE THE SCHEDULING OF ALL WORK WITH THE OWNER, OR BUILDING MANAGER TO MINIMIZE DISRUPTIONS TO THE BUILDING OPERATIONS, AND ITS OCCUPANTS. OBTAIN AND FOLLOW AVAILABLE RULES AND PROCEDURES FOR WORK PERFORMED WITHIN THE BUILDING. COORDINATE WORK PROCEDURES WITH THE REQUIREMENTS OF THE LOCAL AUTHORITIES (WHERE APPLICABLE). PROTECTION OF FURNISHINGS: PROTECT ETR FURNITURE AND EQUIPMENT FROM DAMAGE AND DUST. COORDINATE TEMPORARY REMOVAL AND STORAGE OF FURNITURE AND EQUIPMENT WITH THE OWNER. CONTROLS: TAKE ALL REASONABLE MEASURES TO LIMIT DEMOLITION AND CONSTRUCTION NOISE FROM DISRUPTING EXISTING BUILDING OCCUPANTS. MAINTAIN OR PROVIDE APPROPRIATE EXITS AND EXITWAYS THROUGHOUT CONSTRUCTION. PLUMBING, MECHANICAL AND ELECTRICAL (PME) NOTES: TYPICAL TO ALL CONDITIONS UNLESS OTHERWISE INDICATED OR SPECIFIED: 1)STRUCTURAL MEMBERS SHALL NOT BE IMPAIRED OR UNDERMINED BY IMPROPER CUTTING OR DRILLING. 2)ALL PME WORK SHALL COMPLY WITH ALL APPLICABLE CODES, BE PERFORMED BY A LICENSED TRANSPERSONAL AND BE COMPLETED IN ACCORDANCE WITH THE DIRECTION OF ALL LOCAL BUILDING CODE OFFICIALS. SUB-CONTRACTORS AND TRADES-PERSONS ARE RESPONSIBLE FOR OBTAINING REQUIRED PERMITS FOR THEIR TRADE, SCHEDULING AND COMPLETING REQUIRED INSPECTIONS AND OPERATING ON A REASONABLE AND EFFICIENT SCHEDULE THAT DOES NOT DELAY THE WORK OF OTHER TRADES. 3)ALL MATERIALS SHALL BE SIZED IN ACCORDANCE WITH THE PROPOSED PLANS, ALLOWING FOR FUTURE EXPANSION IF INDICATED. ALL WORK SHALL BE INSTALLED SO THAT REQUIRED PARTS ARE READILY AVAILABLE AND ACCESSIBLE FOR INSPECTION, OPERATION, MAINTENANCE AND REPAIR. 4)ALL PRODUCTS, MATERIALS AND FIXTURES SHALL BE INSTALLED IN A MANNER CONSISTENT WITH SOUND PRACTICE AND QUALITY WORKMANSHIP. FRAMING NOTES: (USE BELOW UNLESS OTHERWISE NOTED) 1- USE STRONG DRIVE CONNECTORS AT ALL COLUMN TO BEAM CONNECTIONS. 2- ALL MULTI PLY BEAMS SHALL BE FASTENED PER MANUFACTURER'S RECOMMENDATION, UNLESS OTHERWISE SPECIFIED. 3- 3/4" T&G SUBFLOORING SHALL BE GLUED AND NAILED TO FRAMING MEMBERS AT 6" O.C.MIN. USE RING SHANK 8(d) NAILS. 4- USE STRONG DRIVE JOIST HANGERS AT ALL FLUSH CONNECTIONS TO BEARING BEAMS 5- COLUMNS SHALL BE CONTINUOUS TO FOUNDATION OR FOOTINGS IN BASEMENTS. CONSULT WITH DESIGN PROFESSIONAL IF CONTINUITY IS NOT POSSIBLE 6- SEE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ENGINEERED STRUCTURAL COMPONENTS. NO HOLES OR NOTCHES SHALL BE MADE TO ANY BEAM WITHOUT APPROVAL OF DESIGN PROFESSIONAL UNLESS ALLOWED IN MANUFACTURER'S INSTALLATION INSTRUCTIONS. 7- USE SIMPSON® METAL CONNECTORS AT ALL COLUMN TO BEAM CONNECTIONS AS WELL AS AT ALL COLUMN BOTTOM ATTACHMENTS. ALSO USE SIMPSON METAL CONNECTORS AT ALL JOIST TO BEAM AND BEAM TO BEAM CONNECTIONS. CONSULT WITH DESIGN PROFESSIONAL IF ANY CONNECTOR IS NOT SPECIFIED IN PLANS. 8- ALL STEEL BEAMS AND COLUMNS TO CONSIST OF Fy=50KSI STEEL GRADE 9- ALL KD & PT WOOD SHALL SET ALL CONSIST OF SPF#2 OR BETTER 10- INSTALL FIRE BLOCKING BETWEEN STORIES PER IRC R302.11, R602.8 11- ALL COLUMNS WHICH PENETRATE ANY HORIZONTAL FRAMED ASSEMBLY SHALL BE SOLID BLOCKED WITH GLUE AND NAILED KD 2X'S BLOCKING TO INSURE LOAD PATH CONTINUITY BETWEEN STORIES. ALL LOAD BEARING COLUMNS SHALL EVENTUALLY REACH A FOUNDATION WALL, FOOTING AND/OR A TRANSITIONAL BEAM. ANY DISCREPANCIES, IF ENCOUNTERED MUST BE COMMUNICATED WITH DESIGN PROFESSIONAL BEFORE PROCEEDING. 12- REPLACE EXISTING DAMAGED JOISTS/STUDS/RAFTERS. 13- ALL WINDOWS WITH THE EXPOSED FRAMING MUST BE REPLACED AS HEADER FOR A MINIMUM DBL 1 1/2" X 9 1/4" WITH DBL JACK STUDS. 14- BUILD TEMPORARY WALLS TO SUPPORT FLOORS AND BEAM SYSTEMS DURING REMOVAL AND REINSTALLATION OF NEW BEAMS, COLUMNS AND JOISTS 15- ALL STAIRCASE, HANDRAILS AND GUARDRAILS TO COMPLY WITH PROVISIONS OF IRC2015 CHAPTER 3 SECTIONS R311 AND R312 AND MA/CMR780 9th EDITION AMENDMENTS. **** IT IS THE CONTRACTOR'S AND/OR SUBCONTRACTOR'S RESPONSIBILITY TO UNDERSTAND THE INTENDED LOAD PATHS AND ENSURE VERTICAL ALIGNMENT OF ALL LOAD BEARING COMPONENTS BEFORE PERMANENT INSTALLATION. THE CONTRACTOR/SUBCONTRACTOR MUST ALSO NOTIFY THE DESIGN PROFESSIONAL IN WRITING OF SUCH CHANGES/VARIATIONS. IF THE ACTUAL SITE DIMENSIONS VARY/CHANGE MORE THAN 1" TO 2" FROM WHAT HAS BEEN DESIGNED AT ANY LOCATION, THE CONTRACTOR/SUBCONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM DESIGN PROFESSIONAL BEFORE EXECUTING THE WORK. ADDITIONALLY CONCRETE SLABS SHALL NOT BE POURED UNTIL ALL COLUMN BEARING FOOTINGS HAVE BEEN POURED AT THEIR DESIGNATED LOCATIONS**** FINISH NOTES: RENDERINGS ARE NOT TO SCALE; ALL RENDERINGS ARE FOR ARTISTIC DEPICTION ONLY. PLAN UPDATES MAY NOT BE REFLECTED IN RENDERINGS. RENDERINGS SHALL NOT BE USED FOR CONSTRUCTION. BASE BOARDS SHALL BE 6" IN ALL ROOMS, UNO. FINAL FINISHES SHALL BE CONFIRMED WITH THE HOME OWNER PRIOR TO APPLICATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISTRIBUTION OF DRAWINGS TO THE SUB-CONTRACTORS UNDER HIS JURISDICTION. THE CONTRACTOR IS TO COORDINATE THE WORK OF ALL SUB-CONTRACTORS, INCLUDING THE TIMING AND SCHEDULING OF THEIR WORK AND THE LAYOUT OF THEIR SYSTEMS. THE CONTRACTOR SHALL PROVIDE ALL SUB-CONTRACTORS WITH NECESSARY POWER AND ACCESS AND CONNECTIONS THROUGH FOUNDATION WALLS AS REQUIRED. THE CONTRACTORS SHALL ACKNOWLEDGE THAT CONSTRUCTION SITES ARE DIFFICULT AND DANGEROUS PLACES TO WORK BY NATURE. AS SUCH, ALL NECESSARY PRECAUTIONS WILL BE TAKEN TO ENSURE SAFETY AND GENERAL WELL BEING OF HIS EMPLOYEES. CONTRACTOR SHALL PROVIDE GUARDS, RAILS, BARRICADE, FENCES, CATCH PLATFORMS, BRIDGING, ETC., AS REQUIRED. CONTRACTORS AND SUB-CONTRACTORS SHALL FURNISH SAMPLES OF ALL MATERIALS, AND/OR FINISHES AS SPECIFIED FOR CONSTRUCTION AT THE REQUEST OF THE DESIGNER, OWNER OF GENERAL CONTRACTOR. LIST OF DRAWINGS: A-1 PROJECT INFORMATION SHEET NOTES AND LEGENDS ILLUSTRATIVE IMAGES A-2 PROJECT INFORMATION SHEET NOTES AND LEGENDS A-3 EXISTING PLANS EXISTING EXTERIOR ELEVATIONS EXISTING 3D VIEW A-4 DEMOLITION PLANS A-5 PROPOSED PLANS, SCHEDULES A-6 PROPOSED PLAN PROPOSED 3D VIEW A-7 EXTERIOR ELEVATIONS A-8 PROPOSED FRAME PLANS A-9 PROPOSED ELECTRICAL PLAN A-10 PROPOSED CROSS SECTIONS PROPOSED INTERIOR ELEVATIONS A-11 ILLUSTRATIVE IMAGES D-0 DETAILS SHEET: SCALE: DATE: 12/18/2025 A-1 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY LIST OF DRAWINGS: A-1 PROJECT INFORMATION SHEET NOTES AND LEGENDS ILLUSTRATIVE IMAGES A/2 PROJECT INFORMATION SHEET A-3 EXISTING BASEMENT PLAN EXISTING FIRST FLOOR PLAN EXISTING SECOND FLOOR PLAN EXISTING ROOF PLAN EXISTING 3D VIEW A-4 EXISTING EXTERIOR ELEVATION A-5 DEMOLITION BASEMENT FLOOR PLAN DEMOLITION FIRST FLOOR PLAN DEMOLITION SECOND FLOOR PLAN DEMOLITION ROOF PLAN A-6 PROPOSED BASEMENT PLAN PROPOSED FIRST FLOOR PLAN PROPOSED SECOND FLOOR PLAN PROPOSED ROOF PLAN A-7 PROPOSED EXTERIOR ELEVATION A-8 PROPOSED FIRST FLOOR FRAME PROPOSED SECOND FLOOR FRAME PROPOSED CEILING FRAME PROPOSED ROOF FRAME A-9 TYPICAL CROSS SECTIONS PROPOSED INTERIOR ELEVATIONS A-10 PROPOSED ILLUSTRATIVE IMAGES A-11 CONSTRUCTION DETAILS PROJECT SCOPE: THIS PROJECT CONSISTS OF THE CONSTRUCTION OF AN ACCESSORY DWELLING UNIT (ADU) WITH A FUNCTIONAL LAYOUT THAT INCLUDES A FULL KITCHEN WITH ISLAND, INTEGRATED LIVING AREAS, ONE BEDROOM, ONE BATHROOM, A LAUNDRY ROOM, AND A CENTRAL HALLWAY THAT ENSURES GOOD CIRCULATION. THE PROJECT WAS DESIGNED TO PROVIDE COMFORT, PRIVACY, AND FLEXIBILITY, AND IS IN COMPLIANCE WITH THE REQUIREMENTS OF THE IRC 2021. STRUCTURAL DESIGN CRITERIA: SOIL MATERIAL SHALL BE INSPECTED DURING EXCAVATION BY SDA ASSOCIATES AND THE BUILDING INSPECTOR BEFORE FOUNDATIONS ARE PLACED. DESIGN IS BASED ON A MINIMUM SOIL LOAD-BEARING PRESSURE OF 2,000 PSI. USE LIVE LOAD (PSF) DEAD LOAD (PSF) SLEEPING ROOMS 30 10 OTHER THAN SLEEPING ROOMS 40 10 ROOF 50 (GROUND SNOW LOAD) 15 INDICATED SHEET: SCALE: DATE: 12/18/2025 A-2 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY PROJECT INFORMATION SHEET, NOTES AND LEGENDS ARCHITECTURAL: A1.MINIMUM 4-MIL POLYETHYLENE VAPOR RETARDER OVER THE INSULATION ON THE INSIDE (WARM SIDE) OF ALL EXTERIOR WALLS AND ROOF CEILINGS - IRC 2021- R702.7 A2.EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTIVE EXTERIOR WALL ENVELOPE. PROVIDE WEATHER-RESISTIVE BARRIER FLASHING DETAILS FOR WINDOWS, DOOR AND OTHER OPENINGS IN THE BUILDING ENVELOPE, INCLUDE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ALSO PROVIDE FLASHING DETAILS FOR OVER DOORS, WINDOWS, SILLS, AT FOUNDATION, COLUMNS, AND OTHER LOCATIONS REQUIRING FLASHING - IRC 2021- R703.1 A3.THE DRAWINGS THAT INSPECTIONS ARE REQUIRED FOR ALL STUCCO AND EIFS SYSTEMS. PROVIDE PRODUCT SPECIFICATIONS AND ICBO EVALUATION REPORT (OR EQUAL) FOR ANY STUCCO OR EIFS SYSTEM USED - IRC 2021- R703.7, R703.9 A4.SILLS OF EXTERIOR WINDOWS WHICH ARE LOCATED MORE THAN 6 FEET ABOVE GRADE, AND LESS THAN 24 INCHES ABOVE THE INTERIOR FLOOR SURFACE MUST MEET SOME NEW REQUIREMENTS. THE AREA OF THE WINDOW LESS THAN 24 INCHES ABOVE THE INTERIOR FLOOR SURFACE MUST NOW BE FIXED OR HAVE AN OPENING OR A GUARD WHICH DOES NOT ALLOW THE PASSAGE OF A 4 INCH DIAMETER SPHERE - IRC 2021- R312.2 A5.A PERMANENT CERTIFICATE SHALL BE POSTED ON OR IN THE ELECTRICAL DISTRIBUTION PANEL LISTING THE PREDOMINANT R-VALUES OF INSULATION INSTALLED IN OR ON CEILING /ROOF, WALLS, FOUNDATION, (SLAB, BASEMENT WALL, CRAWLSPACE WALL AND /OR FLOOR) AND DUCTS OUTSIDE THE CONDITIONED SPACES; U-FACTORS OF WINDOWS, AND THE SOLAR HEAT GAIN COEFFICIENT OF WINDOWS. THE TYPE AND EFFICIENCY OF HEATING, COOLING AND SERVICE WATER HEATING EQUIPMENT SHALL ALSO BE LISTED. NOTE: THE LISTING WILL NOT ALLOW YOU TO DRILL OR MODIFY THE PANEL OR COVER IN ANY WAY TO ACCOMPLISH THIS - IRC N1101.9 A6.STAIR RISER HEIGHT. THE MAXIMUM RISER HEIGHT SHALL BE 8-1/4"INCHES (196 MM). THE RISER SHALL BE MEASURED VERTICALLY BETWEEN LEADING EDGES OF THE ADJACENT TREADS. STATE AMENDMENT TO THE IRC. IF OPEN RISERS ARE PROVIDED, THE OPENINGS SHALL BE LESS THAN 4" - IRC- 2021 R311.7.5.1 (SEE ITEM A63(1) THAT MAY APPLY TO EXTERIOR STAIRS) A7.THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE SMALLEST BY MORE THAN J INCH (9.5 MM) - IRC- 2021 R311.7.5.1 A8.STAIR TREAD DEPTH. THE MINIMUM TREAD DEPTH SHALL BE 9 INCHES (254 MM). THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH - IRC- 2021 R311.7.5.2 A9.STAIR TREAD NOSING: THE RADIUS OF CURVATURE AT THE LEADING EDGE OF THE TREAD SHALL BE NO GREATER THAN 9/16 INCH (914.3 MM). A NOSING NOT LESS THAN¾ INCH (19 MM) BUT NOT MORE THAN 1 ¼ INCHES (32 MM) SHALL BE PROVIDED ON STAIRWAYS WITH SOLID RISERS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST NOSING PROJECTION BY MORE THAN 3/8 INCH (9.5 MM) BETWEEN TWO STORIES, INCLUDING THE NOSING AT THE LEVEL OF FLOORS AND LANDINGS. BEVELING OF NOSING SHALL NOT EXCEED½ INCH (12.7 MM). RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE LEADING EDGE OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES (0.51 RAD) FROM THE VERTICAL. OPEN RISERS ARE PERMITTED, PROVIDED THAT THE OPENING BETWEEN TREADS DOES NOT PERMIT THE PASSAGE OF A 4 INCH (102 MM) DIAMETER SPHERE. IRC- 2021 R311.7.5.3 STRUCTURAL: S1.PROVIDE DOUBLE JOISTS UNDER BEARING PARTITIONS WHICH ARE PARALLEL TO FLOOR JOISTS - IRC-2021 R502.4 S2.PROVIDE SOLID BLOCKING AT BEARING POINTS ON FLOOR JOISTS OR RAFTERS - IRC-2021 R502.7 S3.PROVIDE T&G UNDERLAY-GRADE PLYWOOD AND NAILING SCHEDULE FOR SUBFLOOR IF THERE IS NOT ADDITIONAL PARTICLEBOARD - IRC-2021 R503.2 S4.EXTERIOR WALLS MORE THAN 10' HIGH SHOULD BE INVESTIGATED TO DETERMINE THE ABILITY OF THE STUDS TO RESIST THE REQUIRED WIND LOADS, COMBINED WITH ANY AXIAL LOADS - IBC 2306 S5.FIRE BLOCK STUD SPACES AT SOFFITS, FLOOR AND CEILING JOIST LINES, AT 10 FT VERTICALLY AND HORIZONTALLY, AND AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY SPACES FOR FACTORY-BUILT CHIMNEYS, AND AT ANY OTHER LOCATIONS NOT SPECIFICALLY MENTIONED WHICH COULD AFFORD PASSAGE FOR FLAMES - IRC-2021 R302.11 S6.PROVIDE HURRICANE TIES ON ALL RAFTERS AND TRUSSES - IRC-2021 R802.11.1 S7.CONTRACTOR RESPONSIBLE TO ENSURE NO STRUCTURAL BEARING WALL ARE REMOVED WITHOUT THE INSPECTION OF THE DESIGN ENGINEER AND BUILDING INSPECTOR. ADDITIONALLY, IF ANY EXISTING STRUCTURAL ELEMENTS TO REMAIN SHOULD BE IN GOOD CONDITION. IF NOT SHOULD BE REPLACED. IT IS AT THE DISCRETION OF THE CONTRACTOR TO DETERMINE IF SOMETHING IS IN GOOD CONDITION OR NOT. 5502.3 ALLOWABLE JOIST SPANS. SPANS FOR FLOOR JOISTS SHALL BE IN ACCORDANCE WITH 780 CMR TABLES 5502.3.1(1) AND 5502.3.1(2). FOR OTHER GRADES AND SPECIES AND FOR OTHER LOADING CONDITIONS, REFER TO THE AF&PA SPAN TABLES FOR JOISTS AND RAFTERS, OR THE AF&PA MAXIMUM SPAN CALCULATOR FOR JOISTS & RAFTERS. R802.3.1 CEILING JOIST AND RAFTER CONNECTIONS. WHERE CEILING JOISTS ARE NOT CONNECTED TO THE RAFTERS AT THE TOP WALL PLATE, JOISTS CONNECTED HIGHER IN THE ATTIC SHALL BE INSTALLED AS RAFTER TIES, OR RAFTER TIES SHALL BE INSTALLED TO PROVIDE A CONTINUOUS TIE. WHERE CEILING JOISTS ARE NOT PARALLEL TO RAFTERS, RAFTER TIES SHALL BE INSTALLED. RAFTER TIES SHALL BE NOT LESS THAN 2 INCHES BY 4 INCHES (51 MM BY 102 MM) (NOMINAL), INSTALLED IN ACCORDANCE WITH THE CONNECTION REQUIREMENTS IN TABLE R802.5.1(9), OR CONNECTIONS OF EQUIVALENT CAPACITIES SHALL BE PROVIDED. WHERE CEILING JOISTS OR RAFTER TIES ARE NOT PROVIDED, THE RIDGE FORMED BY THESE RAFTERS SHALL BE SUPPORTED BY A WALL OR GIRDER DESIGNED IN ACCORDANCE WITH ACCEPTED ENGINEERING PRACTICE. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. a. Spans are given in feet and inches. b. Spans are based on minimum design properties for No. 2 grade lumber of Douglas fir-larch, hem-fir, Southern pine, and spruce-pine-fir. c. Building width is measured perpendicular to the ridge. For widths between those shown, spans are permitted to be interpolated. d. NJ = Number of jack studs required to support each end. Where the number of required jack studs equals one, the header is permitted to be supported by an approved framing anchor attached to the full-height wall stud and to the header. e. Spans are calculated assuming the top of the header or girder is laterally braced by perpendicular framing. Where the top of the header or girder is not laterally braced (for example, cripple studs bearing on the header), tabulated spans for headers consisting of 2 × 8, 2 × 10, or 2 × 12 sizes shall be multiplied by 0.70 or the header or girder shall be designed. SEE R301.2(1) TABLE FOR FOOT NOTES GROUND SNOW LOAD WIND SPEED TABLE R301.2(2) 50 PSF TABLE R301.2(2) 115 MPH SEISMIC DESIGN N/A N/A WEATHER! NG FROST LINE TERMITE DECAY WINTER DESIGN TEMP FIGURE 5301.2(3) 48 INCHES. FOR FROST PROTECTED SHALLOW FOUNDATIO NS, SEE R403.3. SEVERE 48 inches (4 ft) FIGURE 5301.2(6) MODERATE TO HEAVY FIGURE 5301.2(7) SLIGHT TO MODERATE APPENDIX 780 CMR 120.J TABLE 120.J.3.2.1 6ºF ICE SHIELD UNDERLAYMENT REQUIRED AS REQUIRED BY THE EXTERIOR ROOF COVERING MANUFACTURER ROOF PITCH AND LOCAL CLIMATE MUST ALSO BE CONSIDERED R905.1.2 FLOOD HAZARD REFER TO APPLICABLE FLOOD INSURANCE RATE MAP (FIRM) REFER TO FEMA FIRM AIR FREEZING INDEX ONLY UTILIZED IN THE DESIGN AND CONST. OF FROST PROTECTED SHALLOW FOUNDATION SEE NOTE J TABLE 5301.2(1) MEAN ANNUAL TEMP ONLY UTILIZED IN DESIGN AND CONST. OF FROST PROTECTED SHALLOW FOUNDATIONS SEE NOTE K TABLE 5301.2(1) TABLE R301.7 ALLOWABLE DEFLECTION OF STRUCTURAL MEMBERSa.b.c.d,e ALLOWABLE STRUCT. MEMBER DEFLECTION RAFTERS HAVING SLOPES GREATER THAN 3: 12 WITH NOFINISHED CEILING ATTACHED TO RAFTERS L/180 INTERIOR WALLS AND PARTITIONS H/180 FLOORS AND PLASTERED CEILINGS L/360 ALL OTHER STRUCTURAL MEMBERS L/240 EXTERIOR WALLS WITH OLASTER OR STUCCO FINISH H/360 EXTERIOR WALLS-WIND LOAD SITH BRITTLE FINISHES H/240 EXTERIOR WALLS-WIND LOADS WITH FLEXIBLE FINISHES L/120 LINTELS SUPPORTING MASONRY VENEER WALLS L/600 Note: L = span length, H = span height. A.THE WIND LOAD SHALL BE PERMITTED TO BE TAKEN AS 0.7 TIMES THE COMPONENT AND CLADDING LOADS FOR THE PURPOSEOF THE DETERMINING DEFLECTION LIMITS HEREIN. B.FOR CANTILEVER MEMBERS, L SHALL BE TAKEN AS TWICE THE LENGTH OFTHE CANTILEVER. C.FOR ALUMINUM STRUCTURAL MEMBERS OR PANELS USED IN ROOFS OR WALLS OF SUNROOM ADDITIONS OR PATIO COVERS, NOT SUPPORTING EDGE OF GLASS OR SANDWICH PANELS, THE TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/60. FOR CONTINUOUS ALUMINUM STRUCTURAL MEMBERS SUPPORTING EDGEOF GLASS, THE TOTAL LOAD DEFLECTION SHALL NOT EXCEED L/175 FOR EACH GLASS LITE OR L/60 FOR THE ENTIRE LENGTH OF THE MEMBER, WHICHEVER IS MORE STRINGENT. FOR SANDWICH PANELS USED IN ROOFS OR WALLS OFSUNROOM ADDITIONS OR PATIO COVERS, THE TOTAL LOAD DEFLECTION SHALL NOTEXCEED L/120. D.DEFLECTION FOR EXTERIOR WALLS WITH INTERIOR GYPSUM BOARD FINISH SHALL BE LIMITED TO AN ALLOWABLE DEFLECTION OF H/180.E. REFER TO SECTION R703.7.2. TABLE R301.5 MINIMUM UNIFORMLY DISTRIBUTED LIVE LOADS (in pounds per square foot) USE LIVE LOAD Attics w/o storage'b 10 Fire escapes 40 Attics with limited storage"b,g 20 Guardrails and handrails'd 200 Habitable attics and attics served 30 Rooms other than sleeping room 40 with fixed stairs Sleeping rooms 30 Balconies (exterior) 40 and decks'e Stairs 40 TABLE R402.1.1 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT CLIMATE ZONE 5 SKYLIGHT(b) U-FACTOR .30 GLAZED FENESTRATION U-FACTOR .55 GLAZED FENESTRATION SHGC NR CEILING R-VALUE 49 WOOD FRAME WALL R-VALUE 20 or 13+5(h) MASS WALL R-VALUE(k) 13/17 FLOOR R-VALUE 30(g) BASEMENT WALL(c) FLOOR 15/19 BASEMENT SLAB(d) AND DEPTH R-VALUE 10,2 FT CRAWL WALL SPACE (c) R-VALUE 15/19 FOR SI: 1 FOOT = 304.8 MM. a.R-VALUES ARE MINIMUMS. U-FACTORS AND SHGC ARE MAXIMUMS. WHEN INSULATION IS INSTALLED IN A CAVITY WHICH IS LESS THAN THE LABEL OR DESIGN THICKNESS OF THE INSULATION, THE INSTALLED R-VALUE OF THE INSULATION SHALL NOT BE LESS THAN THE R-VALUE SPECIFIED IN THE TABLE. b.THE FENESTRATION U-FACTOR COLUMN EXCLUDES SKYLIGHTS. THE SHGC COLUMN APPLIES TO ALL GLAZED FENESTRATION. EXCEPTION: SKYLIGHTS MAY BE EXCLUDED FROM GLAZED FENESTRATION SHGC REQUIREMENTS IN CLIMATE ZONES 1 THROUGH 3 WHERE THE SHGC FOR SUCH SKYLIGHTS DOES NOT EXCEED 0.30. c."15/19 MEANS R-15 CONTINUOUS INSULATION ON THE INTERIOROR EXTERIOR OF THE HOME OR R-19 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL. "15/19" SHALL BE PERMITTED TO BE MET WITH R-13 CAVITY INSULATION ON THE INTERIOR OF THE BASEMENT WALL PLUS R-5 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE HOME. "10/13" MEANS R-10 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR OF THE HOME OR R-13 CAVITY INSULATION AT THE INTERIOR OF THE BASEMENT WALL. d.R-5 SHALL BE ADDED TO THE REQUIRED SLAB EDGER-VALUES FOR HEATED SLABS. INSULATION DEPTH SHALL BE THE DEPTH OF THE FOOTING OR 2 FEET, WHICHEVER IS LESS IN CLIMATE ZONES 1 THROUGH 3 FOR HEATED SLABS. e. THERE ARE NO SHGC REQUIREMENTS IN THE MARINE ZONE. f. BASEMENT WALL INSULATION IS NOT REQUIRED IN WARM-HUMID LOCATIONS AS DEFINED BY FIGURE R301.1 AND TABLE R301.1. 9. OR INSULATION SUFFICIENT TO FILL THE FRAMING CAVITY, R-19 MINIMUM. h. FIRST VALUE IS CAVITY INSULATION, SECOND IS CONTINUOUS INSULATION OR INSULATED SIDING, SO "13+5" MEANS R-13 CAVITY INSULATION PLUS R-5 CONTINUOUS INSULATION OR INSULATED SIDING. IF STRUCTURAL SHEATHING COVERS 40 PERCENT OR LESS OF THE EXTERIOR, CONTINUOUS INSULATION R-VALUE SHALL BE PERMITTED TO BE REDUCED BY NO MORE THAN R-3 IN THE LOCATIONS WHERE STRUCTURAL SHEATHING IS USED- TO MAINTAIN A CONSISTENT TOTAL SHEATHING THICKNESS. i.THE SECOND -VALUE APPLIES WHEN MORE THAN HALF THE INSULATION IS ON THE INTERIOR OF THE MASS WALL Check sources for availability of lumber in lengths greater than 20 feet. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. a. Span exceeds 26 feet in length. EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING WINDOW DN 10' 11'-11" 8'-11 1/2" 8'-8" 10'-10" 8'-7" 3'-9" 11" 11'-6" 11'-11" 10'-0" X 11'-11" 6'-9" X 8'-7" 9'-7" X 13'-6" 11'-6" X 11'-11" EXISTING BEAM TO REMAIN FLOOR JOISTS FLOOR JOISTS PROPOSED EXTERIOR WALL · BUILDING UNDERLAYMENT · 1/2" CDX PLYWOOD SHEATHING · 2x6 #2 SPF STUDS, @ 16" OC · INSULATION, MIN R30 · 1/2" GWB CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 2''X12" RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 5" PITCH R-56 MINERAL WOOL ATTIC INSULATION CEILING ASSEMBLY: R-60 INSULATION 2x10 CEILING JOIST @ 16 O.C. 1/2" PLASTER BOARD W/ VENEER PLASTER COAT EXISTING DEMOLITON PROPOSED PRIMARY BEDROOM BATH BEDROOM PORCH EXISTING STAIR TO THE PORCH EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN TYPICAL WALL SECTION 01TYPICAL WALL SECTION 02TYPICAL WALL SECTION 03TYPICAL GARAGE SECTION EXISTING WINDOW EXISTING WINDOW 28'-9 1/2" 8' 4'-7" 9'-10 1/2" 5'-3 1/2" 14'-1" 7'-8" 4'-7" 3'-3" EXISTING FOUNDATION TO REMAIN EXISTING FOUNDATION TO REMAIN EXISTING FOUNDATION EXISTING PORCH ABOVE EXISTING STAIR TO THE PORCH ABOVE WALL SCHEDULE 2D SYMBOL WALL TYPE EXISTING EXTERIOR WALL EXISTING INTERIOR WALL DECK RAILING/FENCE EXISTING CONCRETE WALL EXISTING PORCH SKIRTING WINDOW SCHEDULE 3D EXTERIOR ELEVATION EXISTING BEAM TO REMAIN FLOOR JOISTS FLOOR JOISTS PROPOSED EXTERIOR WALL · BUILDING UNDERLAYMENT · 1/2" CDX PLYWOOD SHEATHING · 2x6 #2 SPF STUDS, @ 16" OC · INSULATION, MIN R30 · 1/2" GWB CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 2''X12" RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 5" PITCH R-56 MINERAL WOOL ATTIC INSULATION CEILING ASSEMBLY: R-60 INSULATION 2x10 CEILING JOIST @ 16 O.C. 1/2" PLASTER BOARD W/ VENEER PLASTER COAT EXISTING DEMOLITON PROPOSED EXISTING STAIR TO THE PORCH EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN TYPICAL WALL SECTION 01 TYPICAL WALL SECTION 02 TYPICAL WALL SECTION 03 TYPICAL GARAGE SECTION EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWEXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWEXISTING WINDOW EXISTING GROUND LEVEL 0' - 0" EXISTING FIRST FLOOR LEVEL 3' - 1" EXISTING ATTIC LEVEL 11' - 11" EXISTING ROOF LEVEL 21' - 3" EXISTING HOUSE TO REMAIN EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWEXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWEXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOW EXISTING DOOR EXISTING WINDOW EXISTING HOUSE TO REMAIN EXISTING GROUND LEVEL 0' - 0" EXISTING FIRST FLOOR LEVEL 3' - 1" EXISTING ATTIC LEVEL 11' - 11" EXISTING ROOF LEVEL 21' - 3" EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOW EXISTING DOOR EXISTING WINDOW 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF SHEET: SCALE: DATE: 12/18/2025 A-3 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY EXISTING BASEMENT PLAN SCALE: 1/4" = 1'-0"EXISTING FRONT EXTERIOR ELEVATION SCALE: 1/4" = 1'-0" EXISTING RIGHT EXTERIOR ELEVATION SCALE: 1/4" = 1'-0" EXISTING FIRST FLOOR PLAN SCALE: 1/4" = 1'-0" EXISTING ROOF PLAN SCALE: 1/4" = 1'-0" EXISTING 3D VIEW SCALE: NO SCALE INDICATED EXISTING PLANS EXISTING EXTERIOR ELEVATION 3D VIEW EXISTING WINDOW EXISTING WINDOW DEMOLITION WINDOW EXISTING WINDOW EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING WINDOW DN 10' 11'-11" 8'-11 1/2" 8'-8" 10'-10" 8'-7" 3'-9" 11" 11'-6" 11'-11" 10'-0" X 11'-11" 6'-9" X 8'-7" 9'-7" X 13'-6" 11'-6" X 11'-11" EXISTING BEAM TO REMAIN FLOOR JOISTS FLOOR JOISTS PROPOSED EXTERIOR WALL · BUILDING UNDERLAYMENT · 1/2" CDX PLYWOOD SHEATHING · 2x6 #2 SPF STUDS, @ 16" OC · INSULATION, MIN R30 · 1/2" GWB CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 2''X12" RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 5" PITCH R-56 MINERAL WOOL ATTIC INSULATION CEILING ASSEMBLY: R-60 INSULATION 2x10 CEILING JOIST @ 16 O.C. 1/2" PLASTER BOARD W/ VENEER PLASTER COAT EXISTING DEMOLITON PROPOSED PRIMARY BEDROOM BATH BEDROOM PORCH EXISTING STAIR TO THE PORCH EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN DEMOLITION RAILING TEMPORARY SUPPORTS MUST BE PLACED BEFORE THE REMOVAL OF THE ROOF SUPPORT. DEMOLITION POST DEMOLITION POST DEMOLITION POST TYPICAL WALL SECTION 01TYPICAL WALL SECTION 02TYPICAL WALL SECTION 03TYPICAL GARAGE SECTION 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF EXISTING ROOF DEMOLITION ROOF WALL SCHEDULE 2D SYMBOL WALL TYPE EXISTING EXTERIOR WALL EXISTING INTERIOR WALL DECK RAILING/FENCE EXISTING CONCRETE WALL EXISTING PORCH SKIRTING WINDOW SCHEDULE 3D EXTERIOR ELEVATION EXISTING BEAM TO REMAIN FLOOR JOISTS FLOOR JOISTS PROPOSED EXTERIOR WALL · BUILDING UNDERLAYMENT · 1/2" CDX PLYWOOD SHEATHING · 2x6 #2 SPF STUDS, @ 16" OC · INSULATION, MIN R30 · 1/2" GWB CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 2''X12" RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 5" PITCH R-56 MINERAL WOOL ATTIC INSULATION CEILING ASSEMBLY: R-60 INSULATION 2x10 CEILING JOIST @ 16 O.C. 1/2" PLASTER BOARD W/ VENEER PLASTER COAT EXISTING DEMOLITON PROPOSED EXISTING STAIR TO THE PORCH EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN TYPICAL WALL SECTION 01 TYPICAL WALL SECTION 02 TYPICAL WALL SECTION 03 TYPICAL GARAGE SECTION SHEET: SCALE: DATE: 12/18/2025 A-4 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY DEMOLITION PLANS DEMOLITION FIRST FLOOR PLAN SCALE: 1/4" = 1'-0" INDICATED DEMOLITION ROOF PLAN SCALE: 1/4" = 1'-0" NOTE: THIS PROJECT DOES NOT INCLUDE ANY GENERAL RESTRUCTURING OF THE EXISTING HOUSE. ALL EXISTING STRUCTURAL COMPONENTS OF THE HOUSE — INCLUDING FLOOR SLABS, BEAMS, COLUMNS, FOUNDATIONS, AND BEARING WALLS — SHALL REMAIN UNALTERED, EXCEPT IN THE AREA DIRECTLY AFFECTED BY THE NEW ADU ADDITION. LOCALIZED STRUCTURAL REINFORCEMENT, SUCH AS THE INSTALLATION OF A NEW POST OR SUPPORT SYSTEMS, WILL BE PROVIDED SOLELY TO ACCOMMODATE THE REMOVAL OF THE PORCH POSTS THAT CURRENTLY SUPPORT THE ROOF, ENSURING THE CONTINUED STRUCTURAL INTEGRITY OF THE BUILDING. NO OTHER AREAS OF THE EXISTING HOUSE WILL BE MODIFIED. ALL NEW LOADS WILL BE PROPERLY TRANSFERRED AND DISTRIBUTED IN ACCORDANCE WITH THE STRUCTURAL CALCULATIONS AND IN COMPLIANCE WITH APPLICABLE CODES. TECHNICAL NOTE BEFORE PARTIALLY DEMOLISHING THE ROOF IN THE DESIGNATED AREA, PROVIDE ADEQUATE TEMPORARY SHORING TO ENSURE THE STABILITY OF THE EXISTING STRUCTURE. THE SHORING SHALL BE PROPERLY DESIGNED AND INSTALLED TO SUPPORT ALL ROOF LOADS DURING THE DEMOLITION WORK AND SHALL REMAIN IN PLACE UNTIL THE NEW PERMANENT STRUCTURAL SUPPORTS ARE FULLY INSTALLED AND COMPLETED. TECHNICAL NOTE BEFORE REMOVING THE PORCH POSTS THAT SUPPORT THE ROOF, PROVIDE ADEQUATE TEMPORARY SHORING TO ENSURE THE STABILITY OF THE EXISTING STRUCTURE. THE SHORING SHALL BE PROPERLY DESIGNED AND INSTALLED TO SUPPORT ALL ROOF LOADS DURING THE REMOVAL PROCESS AND SHALL REMAIN IN PLACE UNTIL THE NEW PERMANENT STRUCTURAL SUPPORTS ARE FULLY INSTALLED AND COMPLETED. C03C03 C02C02 C04C04 C01C01C01C01 C03C03 C02C02 C04C04 C01C01C01C01 C06C06 C05C05 C07C07 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR EXISTING DOOR D04D04 EXISTING WINDOW W05W05 W03W03 D03D03 W01W01 D02D02 D01D01 D02D02 D05D05 DN DN S1S1 S2S2 S3S3 IE1IE1 IE2IE2 IE3IE3 IE4IE4 IE5IE5 IE6IE6 10' 14'-8" 2'-6 1/2" 8 1/2" 10'-0 1/2" 4'-1" 12'-5"12'-9" 10'-0" X 11'-11" 136 SQ FT 9'-7" X 13'-3" 106 SQ FT 11'-6" X 11'-11" 150 SQ FT 3'-0" X 4'-0" 16 SQ FT 11'-8" X 11'-10" 154 SQ FT 3'-0" X 6'-9" 24 SQ FT 8'-8" X 7'-6" 76 SQ FT 24'-0" X 13'-8" 270 SQ FT PRIMARY BEDROOM BEDROOM PORCH EXISTING STAIR TO THE PORCH EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN CLOSET HALL BEDROOM BATH W1 D-0 W1 D-0 PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH W1 D-0 W1 D-0 PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH W1 D-0 W1 D-0 PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH ALL INSULATION IN THIS WALL WILL BE REPLACED WITH FIRE- RESISTANT: . (UL305 FIRE RESISTANCE 1 . HOUR) WITH 2 LAYERS 5/8" . TYPE X GYP BD AND PLASTER . ON BOTH SIDES, AND 3 1/2" . ROXUL® R-15 MINERAL WOOL INSULATION WF2 D-0 WF2 D-0 PROPOSED INTERIOR WALL: - 2" x 4" SPF #2 STUDS @ 16" OC - CAVITY INSULATION: R-13 MIN (WHERE REQUIRED) - 1/2" GYPSUM BOARD (BOTH SIDES) W2 D-0 W2 D-0 PROPOSED INTERIOR WALL: - 2" x 4" SPF #2 STUDS @ 16" OC - CAVITY INSULATION: R-13 MIN (WHERE REQUIRED) - 1/2" GYPSUM BOARD (BOTH SIDES) W2 D-0 W2 D-0 W2 D-0 W2 D-0 PROPOSED INTERIOR WALL: - 2" x 4" SPF #2 STUDS @ 16" OC - CAVITY INSULATION: R-13 MIN (WHERE REQUIRED) - 1/2" GYPSUM BOARD (BOTH SIDES) PROPOSED INTERIOR WALL: - 2" x 4" SPF #2 STUDS @ 16" OC - CAVITY INSULATION: R-13 MIN (WHERE REQUIRED) - 1/2" GYPSUM BOARD (BOTH SIDES) EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN KITCHEN ALL INSULATION IN THIS WALL WILL BE REPLACED WITH FIRE- RESISTANT: . (UL305 FIRE RESISTANCE 1 . HOUR) WITH 2 LAYERS 5/8" . TYPE X GYP BD AND PLASTER . ON BOTH SIDES, AND 3 1/2" . ROXUL® R-15 MINERAL WOOL INSULATION ***TEMPORARY SUPPORTS MUST BE PLACED BEFORE THE REMOVAL OF THE ROOF SUPPORT. LINEN 3' 0" X 2' 2" EXTERIOR EXHAUST VENT — REAR- VENTED DIRECTLY TO THE BACK, SERVING AS THE DEDICATED MICROWAVE EXHAUST OUTLET. PROPOSED NICHE PROPOSED 6" X 6" POST ALIGNED WITH THE FOUNDATION WALL PROPOSED 6" X 6" POST ALIGNED WITH THE FOUNDATION WALL PROPOSED 4" X 6" POST ALIGNED WITH THE FOUNDATION WALL PROPOSED 4" X 6" POST ALIGNED WITH THE FOUNDATION WALL PROPOSED STRUCTURAL FLUSHED BEAM: (3)1-3/4"x14" LVLs PROPOSED FUTURE BIDET CONNECTION POINT PROPOSED MINI- SPLIT SYSTEM PROPOSED MINI- SPLIT SYSTEM 5'-2" X 3'-3" 21 SQ FT W02W02 LAUNDRY 10' 11'-11" 8'-7" 8'-8" 10'-10" 8'-7" 3'-9" 1'-2 1/2" 12'-1" 11'-11" 22'-1" 25'-2" 11'-9 1/2" 11'-7 1/2" 3'8'-7 1/2" 7'-5 1/2" 4' 9'-4" 16'-7 1/2"7'-4" 6'-2" 2'-9 1/2" 3'-3" 3'-4" 3'-4 1/2"3'-1 1/2"2'-11 1/2" 7'-6 1/2" 2'-5 1/2" 1'-9 1/2" 3' 6'-8 1/2" 5'-11" 1'-6 1/2" 2'-2" 5'-3 1/2" 3' 3' 3'-8 1/2" 4'-7" 3' 8'-3 1/2" 5'-2" 3'-3" SD CO/SD SD DP EXISTING WINDOW EXISTING WINDOW W07W07 W07W07 W07W07 S1S1 S2S2 S3S3 28'-5 1/2" 7'-11" 4'-7" 5'-3 1/2" 12'-11 1/2" 7'-8" 4'-7" 3'-3" 21'-3" 13'-6" 6'-6 1/2" 22'-11" 14'-8 1/2" 7'-9" 14'-5 1/2"9'-0 1/2" 23'-6" 21'-3" 12'-5" 23'-6" X 21'-3" 571 SQ FT EXISTING FOUNDATION TO REMAIN EXISTING FOUNDATION TO REMAIN EXISTING FOUNDATION EXISTING PORCH ABOVE EXISTING STAIR TO THE PORCH ABOVE LANDING ABOVE PROPOSED STAIR ACCESS TO ADU CRAWL SPACE PROPOSED FOUNDATION EXISTING FOUNDATION TO REMAIN USE HYDRAULIC CEMENT AT JOINT BETWEEN FOUNDATIONS WHILE BELOW GRADE AFTER DE-FORMING. INSTALL #5 REBARS AT 12" O.C. W/ 10" MIN. EMBEDMENT EACH WAY. INTO EXISTING FOUNDATION WALL AND NEW CONCRETE FOUNDATION WALL. USE 2 PART EPOXY ADHESIVE TO EMBED REBARS INTO EXISTING FOUNDATION WALL CRAW SPACE FOUNDATION: PLEASE, SEE FOUNDATION NOTE 01 ON PAGE A-4PROPOSED FOUNDATION EXISTING FOUNDATION TO REMAIN USE HYDRAULIC CEMENT AT JOINT BETWEEN FOUNDATIONS WHILE BELOW GRADE AFTER DE-FORMING. INSTALL #5 REBARS AT 12" O.C. W/ 10" MIN. EMBEDMENT EACH WAY. INTO EXISTING FOUNDATION WALL AND NEW CONCRETE FOUNDATION WALL. USE 2 PART EPOXY ADHESIVE TO EMBED REBARS INTO EXISTING FOUNDATION WALL CRAW SPACE FOUNDATION: PLEASE, SEE FOUNDATION NOTE 01 ON PAGE A-4 IF THE EXISTING FOUNDATION DOES NOT HAVE INSULATION, IT MUST BE INSTALLED WITH THE SAME SPECIFICATIONS AS THE INSULATION PROPOSED FOR THE NEW FOUNDATION. PROPOSED 10" CONCRETE FOUNDATION WALL ON 24" X 12" CONTINUOUS CONCRETE FTG. 3000 PSI CONCRETE MIN. BOTTOM OF FTG ON UNDISTURBED SOIL. PROPOSED 10" CONCRETE FOUNDATION WALL ON 24" X 12" CONTINUOUS CONCRETE FTG. 3000 PSI CONCRETE MIN. BOTTOM OF FTG ON UNDISTURBED SOIL.F1 D-0 F1 D-0 F2 D-0 F2 D-0 F1 D-0 F1 D-0 ***CRAWL SPACE FOUNDATION: CONTINUOUS CONCRETE FOOTING LOCATED 48" BELOW FINISHED GRADE (FROST DEPTH). CONCRETE 3, 000 PSI MINIMUM. FOOTINGS REINFORCED WITH (2) #4 REBARS CONTINUOUS, ONE NEAR THE TOP AND ONE NEAR THE BOTTOM OF THE FOOTING. 10" CONCRETE FOUNDATION WALLS REINFORCED PER STRUCTURAL NOTES. INTERIOR CRAWL SPACE FLOOR TO REMAIN SOIL OR RECEIVE NON- STRUCTURAL MUD SLAB (OPTIONAL). PROVIDE TERMITE PROTECTION AND FOUNDATION INSULATION AS REQUIRED BY LOCAL CODE. CRAW SPACE FOUNDATION: PLEASE, SEE FOUNDATION NOTE 01 ON PAGE A-4 PROPOSED 6x6 PT POST WITH SONOTUBE 12'' W/ 48" DEEP PROPOSED 6x6 PT POST WITH SONOTUBE 12'' W/ 48" DEEP PROPOSED FOUNDATION EXISTING FOUNDATION TO REMAIN SO D-0 SO D-0 SO D-0 SO D-0 PROPOSED STRUCTURAL DROPPED BEAM: (3) 1-3/4" x 18" LVLs BP D-0 BP D-0 BP D-0 BP D-0 25'-2" 12'-9" DOOR SCHEDULE 3D EXTERIOR ELEVATION NUMBER QTY FLOOR WIDTH HEIGHT R/O DESCRIPTION D01 1 1 30 "80 "32"X82 1/2"2 DR. BIFOLD-LOUVERED D02 2 1 30 "80 "62"X82 1/2"POCKET-DOOR P04 D03 1 1 32 "80 "34"X83"EXT. HINGED-DOOR E21 D04 1 1 36 "80 "38"X83"EXT. HINGED-DOOR E21 D05 1 1 52 "80 "54"X82 1/2"4 DR. BIFOLD-LOUVERED CABINET SCHEDULE 3D ELEVATION NUMBER QTY FLOOR WIDTH DEPTH HEIGHT C01 2 1 24 "14 "36 " C02 1 1 32 "24 "42 " C03 1 1 30 "24 "36 " C04 1 1 32 "24 "36 " C05 1 1 36 "28 "26 " C06 1 1 26 "36 "96 " C07 1 1 30 "12 "40 " WINDOW SCHEDULE 3D EXTERIOR ELEVATION NUMBER QTY R/O WIDTH HEIGHT EGRESS DESCRIPTION W01 1 40"X64"39 "63 "YES DOUBLE HUNG W02 1 21"X53"20 "52 "DOUBLE HUNG W03 1 23"X27"22 "26 "SINGLE HOPPER W04 1 17"X9"16 "8 "LOUVERED W05 1 27"X41"26 "40 "DOUBLE HUNG W07 3 33"X17"32 "16 "LOUVERED NOTE SCHEDULE NEW HEADER: SEE TABLE R602.7(2) WALL SCHEDULE 2D SYMBOL WALL TYPE EXISTING CONCRETE WALL EXISTING EXTERIOR WALL EXISTING INTERIOR WALL DECK RAILING/FENCE EXISTING PORCH SKIRTING PORPOSED CONCRETE WALL-10 PROPOSED EXTERIOR RESISTANCE FIRE WALL PROPOSED INTERIOR WALL PROPOSED EXTERIOR WALL EXISTING STAIR TO THE PORCH EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAINEXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN ELECTRICAL SCHEDULE 2D SYMBOL DESCRIPTION CO/SMOKE DETECTOR CAGED LANTERN SCONCE DUPLEX ELECTRIC RANGE ELECTRICAL PANEL EXHAUST GFCI GARBAGE DISPOSAL GARBAGE DISPOSAL SWITCH CO/SDCO/SD DP SHEET: SCALE: DATE: 12/18/2025 A-5 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY PROPOSED FIRST FLOOR PLAN SCALE: 1/4" = 1'-0" PROPOSED BASEMENT PLAN SCALE: 1/4" = 1'-0"PROPOSED PLANS, SCHEDULE INDICATED NOTE 01 – CRAWL SPACE FOUNDATION 1. FROST PROTECTION: ALL FOUNDATION FOOTINGS AND WALLS SHALL EXTEND TO A MINIMUM DEPTH OF 48 INCHES BELOW FINISHED GRADE IN ACCORDANCE WITH 2021 IRC SECTION R403.1.4.1 AND LOCAL FROST DEPTH REQUIREMENTS. 2. CRAWL SPACE FOUNDATION WALLS: PROVIDE 10" REINFORCED CONCRETE FOUNDATION WALLS FORMING THE PERIMETER OF THE CRAWL SPACE. WALLS SHALL BE REINFORCED PER STRUCTURAL DESIGN AND SHALL BEAR ON CONTINUOUS CONCRETE FOOTINGS PLACED ON UNDISTURBED SOIL. 3. CRAWL SPACE FLOOR: CRAWL SPACE FLOOR SHALL BE EXPOSED EARTH OR OPTIONAL NON-STRUCTURAL MUD SLAB, PER 2021 IRC SECTION R408. WHERE EXPOSED EARTH REMAINS, PROVIDE GROUND VAPOR CONTROL PER ITEM 4. 4. VAPOR BARRIER (WHEN REQUIRED): WHEN THE CRAWL SPACE IS CONDITIONED OR WHEN WALL INSULATION IS PROVIDED, INSTALL A 6-MIL POLYETHYLENE VAPOR RETARDER OVER EXPOSED EARTH WITH 6" MINIMUM OVERLAP AND SEALED JOINTS, IN ACCORDANCE WITH IRC SECTION R408.3. 5. CONNECTION TO EXISTING FOUNDATION: PROVIDE MECHANICAL CONNECTION BETWEEN NEW AND EXISTING FOUNDATION WALLS USING DOWELS OR EPOXY-SET #4 REBAR PER STRUCTURAL DESIGN TO PROVIDE STRUCTURAL CONTINUITY AND MINIMIZE DIFFERENTIAL MOVEMENT. 6. THERMAL INSULATION – FOUNDATION WALLS: WHEN THE FLOOR ABOVE THE CRAWL SPACE IS PART OF THE CONDITIONED BUILDING ENVELOPE, PROVIDE MINIMUM R-15 CONTINUOUS INSULATION ON THE INTERIOR OR EXTERIOR FACE OF THE FOUNDATION WALLS, PER 2021 IRC SECTION N1102.2.10 (R402.2.10) AND IECC CZ-5 REQUIREMENTS. INSULATION SHALL EXTEND FROM THE FLOOR LEVEL TO THE TOP OF THE FOOTING. 7. CRAWL SPACE VENTILATION OR CONDITIONING: CRAWL SPACE SHALL BE EITHER VENTED OR CONDITIONED PER 2021 IRC SECTION R408. A) VENTED OPTION: PROVIDE VENT OPENINGS EQUAL TO 1 SQ. FT. PER 150 SQ. FT. OF CRAWL SPACE AREA (UNLESS VAPOR BARRIER IS PROVIDED). B) UNVENTED/CONDITIONED OPTION: PROVIDE WALL INSULATION, AIR SEALING, AND SUPPLY/RETURN AIR AS REQUIRED BY SECTION R408.3. 8. TERMITE PROTECTION: PROVIDE TERMITE PROTECTION AT ALL FOUNDATION WALLS AND PENETRATIONS AS REQUIRED BY IRC SECTION R318 AND LOCAL CODE REQUIREMENTS. 9. FOUNDATION DRAINAGE: WHERE REQUIRED BY SITE CONDITIONS, INSTALL A PERIMETER DRAINAGE SYSTEM IN ACCORDANCE WITH IRC SECTION R405.1, INCLUDING FILTER FABRIC, GRAVEL BEDDING, AND DISCHARGE TO APPROVED OUTLET. 10. INSPECTIONS: ALL EXCAVATION, FOOTINGS, FOUNDATION WALLS, DAMP-PROOFING, VAPOR CONTROL, AND CONNECTIONS TO EXISTING FOUNDATION SHALL BE SUBJECT TO BUILDING DEPARTMENT INSPECTION AND APPROVAL PRIOR TO BACKFILL AND FRAMING. 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 8 : 12 3 : 12 3 : 12 3 : 12 23'-6" 28'-10 1/2" 22'-1" 13'-11 1/2"13'-11 1/2" 6'-9 1/2" 27'-11" 6'-2 1/2" 6'-3" 8'-9 1/2" 13'-11 1/2" EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN PROPOSED ROOF PROPOSED ROOF R1 D-0 R1 D-0 RD D-0 RD D-0 R1 D-0 R1 D-0 R2 D-0 R2 D-0 R1 D-0 R1 D-0 SD D-0 SD D-0 R1 D-0 R1 D-0 R2 D-0 R2 D-0 R1 D-0 R1 D-0 SD D-0 SD D-0 ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT -ASPHALT SHINGLES OVER 1 LAYER OF APPROVED UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX PLYWOOD SHEATHING (IRC R803). - 2"X10" RAFTERS @ 16" O.C., WITH SIMPSON H2.5A HURRICANE TIES (IRC R802.11) AND RAFTER HANGERS WHERE REQUIRED. - 2"X12" RIDGE BOARD WITH FULL BEARING SUPPORT (IRC R802.3). - ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 – MASSACHUSETTS). - 1"X3" WOOD STRAPPING FOR CEILING SYSTEM. - 1/2" GWB CEILING FINISH (IRC R702.3). - ROOF PITCH 3:12. ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT -ASPHALT SHINGLES OVER 1 LAYER OF APPROVED UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX PLYWOOD SHEATHING (IRC R803). - 2"X10" RAFTERS @ 16" O.C., WITH SIMPSON H2.5A HURRICANE TIES (IRC R802.11) AND RAFTER HANGERS WHERE REQUIRED. - 2"X12" RIDGE BOARD WITH FULL BEARING SUPPORT (IRC R802.3). - ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 – MASSACHUSETTS). - 1"X3" WOOD STRAPPING FOR CEILING SYSTEM. - 1/2" GWB CEILING FINISH (IRC R702.3). - ROOF PITCH 3:12. Static Vent Type - Fixed aluminum attic vent for passive ventilation Static Vent Type - Fixed aluminum attic vent for passive ventilation EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN PROPOSED CRICKET ROOF TECHNICAL NOTE: DURING CONSTRUCTION, THE CONTRACTOR SHALL VERIFY ON SITE ANY POTENTIAL INTERFERENCE BETWEEN THE NEW ROOF AND THE EXISTING DORMER WINDOW. IF ANY IMPACT OR OBSTRUCTION IS IDENTIFIED, THE WINDOW SHALL BE REPLACED AS NECESSARY TO ENSURE PROPER FIT AND FUNCTIONALITY. SHEET: SCALE: DATE: 12/18/2025 A-6 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY PROPOSED PLAN 3D VIEW INDICATED PROPOSED ROOF PLAN SCALE: 1/4" = 1'-0" PROPOSED 3D VIEW SCALE: NO SCALE PROPOSED 3D VIEW SCALE: NO SCALE PROPOSED ROOF PROPOSED CRICKET ROOF PROPOSED 3D VIEW SCALE: NO SCALE EXISTING DOOR EXISTING WINDOW EXISTING WINDOW W05W05 W07W07 EXISTING DOOR EXISTING WINDOW EXISTING WINDOW W05W05 W07W07 EXISTING HOUSE TO REMAIN EXISTING GROUND LEVEL 0' - 0" EXISTING FIRST FLOOR LEVEL 3' - 1" EXISTING ATTIC LEVEL 11' - 11" EXISTING ROOF LEVEL 21' - 3" EXISTING DOOR EXISTING WINDOW EXISTING WINDOW W05W05 W07W07 EXISTING DOOR EXISTING WINDOW EXISTING WINDOW W05W05 W07W07 W01W01 W07W07 W01W01 W07W07 EXISTING WINDOW W02W02 D03D03 EXISTING WINDOW W02W02 D03D03 EXISTING HOUSE TO REMAIN EXISTING GROUND LEVEL 0' - 0" EXISTING FIRST FLOOR LEVEL 3' - 1" EXISTING ATTIC LEVEL 11' - 11" EXISTING ROOF LEVEL 21' - 3" W01W01 W07W07 W01W01 W07W07 EXISTING WINDOW W02W02 D03D03 EXISTING WINDOW W02W02 D03D03 W04W04 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW W03W03 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWW07W07 EXISTING GROUND LEVEL 0' - 0" EXISTING FIRST FLOOR LEVEL 3' - 1" EXISTING ATTIC LEVEL 11' - 11" EXISTING ROOF LEVEL 21' - 3" EXISTING HOUSE TO REMAIN W04W04 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW W03W03 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWW07W07 SHEET: SCALE: DATE: 12/18/2025 A-7 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY PROPOSED FRONT EXTERIOR ELEVATION SCALE: 1/4" = 1'-0" PROPOSED RIGHT EXTERIOR ELEVATION SCALE: 1/4" = 1'-0" PROPOSED BACK EXTERIOR ELEVATION SCALE: 1/4" = 1'-0" PROPOSED EXTERIOR ELEVATIONS INDICATED 2'-11" 3' 4'-5 1/2" 4'-7 1/2" 3'-8" 3' 4'-1" 9'-6 1/2" 25'-2" 22'-11" 21'-3" 12'-5"12'-9" 2X8" PT JOISTS @ 16" O.C PROPOSED STAIR ACCESS TO ADU PROPOSED 6x6 PT POST WITH SONOTUBE 12'' W/ 48" DEEP PROPOSED 6x6 PT POST WITH SONOTUBE 12'' W/ 48" DEEP EXISTING FLOOR JOIST TO REMAIN (3) 2"X8" PT BEAM 2X8" PT LEDGER CARRIAGE BOLTS @ 16" O.C (2) 2X8" PT JOISTS (2) 2X8" PT RIM 2X10" FLOOR JOISTS @ 16" O.C. please, see the table R502.3.1 (2) 2X10" FLOOR JOISTS @ 16" O.C. please, see the table R502.3.1 (2) PROPOSED STRUCTURAL DROPPED BEAM: (3) 1-3/4" x 18" LVLs EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN 22'-6 1/2" 6'-5" 22'-6 1/2" 12'-4"12'-8" PROPOSED STAIR ACCESS TO ADU EXISTING FLOOR JOIST TO REMAINEXISTING FLOOR JOIST TO REMAIN EXISTING FLOOR JOIST TO REMAIN EXISTING FLOOR JOIST TO REMAIN EXISTING FLOOR JOIST TO REMAINEXISTING FLOOR JOIST TO REMAIN EXISTING FLOOR JOIST TO REMAIN NOTE SCHEDULE NEW HEADER: SEE TABLE R602.7(2) EXISTING HEADER: SEE TABLE 1 2 TRIPLE 1-3/4" × 9-1/2" VERSA- LAM® LVL 2.1E 2800 PROPOSED 6" X 6" POST ALIGNED WITH THE FOUNDATION WALL PROPOSED 6" X 6" POST ALIGNED WITH THE FOUNDATION WALL PROPOSED STRUCTURAL FLUSHED BEAM: (3) 1-3/4"x14" LVLs PROPOSED 4" X 6" POST ALIGNED WITH THE FOUNDATION WALL PROPOSED 4" X 6" POST ALIGNED WITH THE FOUNDATION WALL 2x 8" CEILING JOISTS @ 16" O.C. please, see the table R802.5.1 (1) 2x 8" CEILING JOISTS @ 16" O.C. please, see the table R802.5.1 (1) EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN 22 22 2222 22 22 22 11 11 11 11 11 11 11 11 11 11 11 11 27'-11" 13'-11 1/2"13'-11 1/2" 23'-6"22'-1" 28'-10 1/2" 1 1 '-1 1 " 3'-11 1/2" 6'-7 1/2" 7'-9" 9'-3" 6'-3" 8'-7 1/2" 6'-2 1/2" EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN RD D-0 RD D-0 SD D-0 SD D-0 R2 D-0 R2 D-0 SD D-0 SD D-0 R2 D-0 R2 D-0 CT1/CT2 D-0 CT1/CT2 D-0 2X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5) RAFTERS SPANS 2X10" @16 O.C ROOF RAFTERS SEE TABLE R802.4.1(5) RAFTERS SPANS COLLAR TIE ON EACH RAFTERS (2X6) RIDGE BOARD 2"x12" V A L L E Y S R A F T E R (2 ) 1 ½" × 1 1 ¼ VALLEYS RAFTER (2) 1 ½" × 11 ¼ PROPOSED ROOF PROPOSED ROOF CRICKET ROOF NOTE SCHEDULE NEW HEADER: SEE TABLE R602.7(2) EXISTING HEADER: SEE TABLE 1 2 EXISTING HOUSE TO REMAIN EXISTING HOUSE TO REMAIN SHEET: SCALE: DATE: 12/18/2025 A-8 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY INDICATED PROPOSED FIRST FLOOR FRAME PLAN SCALE: 1/4" = 1'-0" PROPOSED FRAME PLANS PROPOSED CEILING FRAME PLAN SCALE: 1/4" = 1'-0" PROPOSED ROOF FRAME PLAN SCALE: 1/4" = 1'-0" FRAMING DETAILS: RAFTERS SHALL BE FRAMED TO RIDGE BOARD OR TO EACH OTHER WITH A GUSSET PLATE AS S TIE. RIDGE BOARD SHALL BE AT LEAST ONE-INCH (25.4mm) NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT AND OF THE RAFTER. AT ALL VALLEYS AND HIPS THERE SHALL BE A VALLEY OR HIP RAFTER NOT LESS THAN TWOINCH (51mm) NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT AND OF THE RAFTER. HIP AND VALLEY RAFTERS SHALL BE SUPPORTED AT THE RIDGE BY A BRACE TO A BEARING PARTITION OR BE DESIGNED TO CARRY AND DISTRIBUTE THE SPECIFIC LOAD AT THAT PONT. WHERE THE ROOF PITCH IS LESS THAN THREE UNITS VERTICAL IN 12 UNITS HORIZONTAL (25% SLOPE), STRUCTURAL MEMBERS THAT SUPPORT RAFTERS AND CEILING JOISTS, SUCH AS RIDGE BEAMS, HIPS AND CEILING JOISTS, SUCH RIDGE BEAMS, HIPS AND VALLEYS, SHALL BE DESIGNED AS BEAMS. DN DN GFCI M RA GD GD R GFCI EP R R R RR R R R R R 3 3 3 3 PRIMARY BEDROOM BEDROOM PORCH CLOSET HALL BEDROOM BATH PROPOSED ELECTRICAL PANEL KITCHEN EXISTING HOUSE TO REMAIN DP DP LAUNDRY SD CO/SD SD R R GFCIGFCI R R 3 3 TV GFCI R PROPOSEDELECTRICALPANEL ELECTRICAL SCHEDULE 2D SYMBOL DESCRIPTION COMMENTS CO/SMOKE DETECTOR CAGED LANTERN SCONCE DUPLEX ELECTRIC RANGE ELECTRICAL PANEL EXHAUST GFCI GARBAGE DISPOSAL GARBAGE DISPOSAL SWITCH MICROWAVE RECESSED DOWN LIGHT 6 REFRIGERATOR SINGLE POLE SMOKE DETECTOR 1 TELEVISION JACK THREE WAY DISC PENDANT CO/SD RA EP GFCI GD GD M R R SD TV 3 CO/SD RA EP GFCI GD GD M R R SD TV 3 EXISTING HOUSE TO REMAIN DP DP SHEET: SCALE: DATE: 12/18/2025 A-9 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY INDICATED PROPOSED ELECTRICAL PLAN PROPOSED ELECTRICAL PLAN SCALE: 1/4" = 1'-0" W04W04 D05D05 W04W04 W07W07 3' 8' CRAW SPACE LIVING KITCHEN PROPOSED 6x6 PT POST WITH SONOTUBE 12'' W/ 48" DEEP SO D-0 SO D-0 PROPOSED SONOTUBE 12'' W/ 48" DEEP F1 D-0 F1 D-0 F1 D-0 F1 D-0 PROPOSED 10" CONCRETE FOUNDATION WALL ON 24" X 12" CONTINUOUS CONCRETE FTG. 3000 PSI CONCRETE MIN. BOTTOM OF FTG ON UNDISTURBED SOIL. W1 D-0 W1 D-0 PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH DOUBLE OUTLET DOUBLE OUTLET TV DOUBLE SWITCH LIGHTING LIGHTING LIGHTING REFRIGERATOR OUTLET LIGHTING LIGHTING PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH W1 D-0 W1 D-0 CONSTRUCTION CEILING · 1/2" GYPSUM BOARD (GWB) · 1X3 WOOD STRAPPING · JOIST @ 16" O.C. · R-49 INSULATION BETWEEN JOISTS · VAPOR BARRIER (IF REQUIRED BY CLIMATE ZONE) · CEILING FINISH TO MATCH COLOR AND MATERIAL OF LIVING ROOM CEILING 2x 8" CEILING JOISTS @ 16" O.C. FL1 D-0 FL1 D-0 ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT -ASPHALT SHINGLES OVER 1 LAYER OF APPROVED UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX PLYWOOD SHEATHING (IRC R803). - 2"X10" RAFTERS @ 16" O.C., WITH SIMPSON H2.5A HURRICANE TIES (IRC R802.11) AND RAFTER HANGERS WHERE REQUIRED. - 2"X12" RIDGE BOARD WITH FULL BEARING SUPPORT (IRC R802.3). - ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 – MASSACHUSETTS). - 1"X3" WOOD STRAPPING FOR CEILING SYSTEM. - 1/2" GWB CEILING FINISH (IRC R702.3). - ROOF PITCH 3:12. ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT -ASPHALT SHINGLES OVER 1 LAYER OF APPROVED UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX PLYWOOD SHEATHING (IRC R803). - 2"X10" RAFTERS @ 16" O.C., WITH SIMPSON H2.5A HURRICANE TIES (IRC R802.11) AND RAFTER HANGERS WHERE REQUIRED. - 2"X12" RIDGE BOARD WITH FULL BEARING SUPPORT (IRC R802.3). - ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 – MASSACHUSETTS). - 1"X3" WOOD STRAPPING FOR CEILING SYSTEM. - 1/2" GWB CEILING FINISH (IRC R702.3). - ROOF PITCH 3:12. SD/R2 D-0 SD/R2 D-0 SD/R2 D-0 SD/R2 D-0 R1 D-0 R1 D-0 2 X 1 0 " @ 1 6 O .C R O O F R A F T E R S 2X10" @16 O.C ROOF RAFTERS CT1/CT2 D-0 CT1/CT2 D-0 COLLAR TIE (2X6) CONSTRUCTION FIRST FLOOR: FLOOR ASSEMBLY: FLOOR FINISH 3/4" T&G PLYWOOD SUBFLOOR JOIST @16" O.C. WITH R-30 INSULATION AIR-SEALING OF THE FLOOR ASSEMBLY TO PREVENT TEMPERATURE AND AIR TRANSFER 2X10" FLOOR JOISTS @ 16" O.C.2X10" FLOOR JOISTS @ 16" O.C. PROPOSED STRUCTURAL DROPPED BEAM: (3) 1-3/4" x 18" LVLs PROPOSED STRUCTURAL FLUSHED BEAM: (3 )1-3/4"x14" LVLs 2x 8" CEILING JOISTS @ 16" O.C. TRIPLE 1-3/4" × 9-1/2" VERSA-LAM® LVL 2.1E 2800 W04W04 D05D05 W04W04 W07W07 W02W02 D03D03 W02W02 D03D03 W01W01W01W01 W07W07 CRAW SPACE LIVING BEDROOM F1 D-0 F1 D-0 F1 D-0 F1 D-0 PROPOSED 10" CONCRETE FOUNDATION WALL ON 24" X 12" CONTINUOUS CONCRETE FTG. 3000 PSI CONCRETE MIN. BOTTOM OF FTG ON UNDISTURBED SOIL. W1 D-0 W1 D-0 DOUBLE OUTLET SWITCH LIGHTING LIGHTING SMOKE DETECTOR PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH W1 D-0 W1 D-0 CONSTRUCTION CEILING · 1/2" GYPSUM BOARD (GWB) · 1X3 WOOD STRAPPING · CEILING JOIST @ 16" O.C. · R-49 INSULATION BETWEEN JOISTS · VAPOR BARRIER (IF REQUIRED BY CLIMATE ZONE) · CEILING FINISH TO MATCH COLOR AND MATERIAL OF LIVING ROOM CEILING FL1 D-0 FL1 D-0 ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT -ASPHALT SHINGLES OVER 1 LAYER OF APPROVED UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX PLYWOOD SHEATHING (IRC R803). - 2"X10" RAFTERS @ 16" O.C., WITH SIMPSON H2.5A HURRICANE TIES (IRC R802.11) AND RAFTER HANGERS WHERE REQUIRED. - 2"X12" RIDGE BOARD WITH FULL BEARING SUPPORT (IRC R802.3). - ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 – MASSACHUSETTS). - 1"X3" WOOD STRAPPING FOR CEILING SYSTEM. - 1/2" GWB CEILING FINISH (IRC R702.3). - ROOF PITCH 3:12. SD/R2 D-0 SD/R2 D-0 2X10" @16 O.C ROOF RAFTERS CT1/CT2 D-0 CT1/CT2 D-0 COLLAR TIE (2X6) LIGHTING DOUBLE OUTLETDOUBLE OUTLET W2 D-0 W2 D-0 PROPOSED INTERIOR WALL: - 2" x 4" SPF #2 STUDS @ 16" OC - CAVITY INSULATION: R-13 MIN (WHERE REQUIRED) - 1/2" GYPSUM BOARD (BOTH SIDES) CONSTRUCTION FIRST FLOOR: FLOOR ASSEMBLY: FLOOR FINISH 3/4" T&G PLYWOOD SUBFLOOR JOIST @16" O.C. WITH R-30 INSULATION AIR-SEALING OF THE FLOOR ASSEMBLY TO PREVENT TEMPERATURE AND AIR TRANSFER PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH 2X10" FLOOR JOISTS @ 16" O.C. 2x 8" CEILING JOISTS @ 16" O.C. W02W02 D03D03 W02W02 D03D03 W01W01W01W01 W07W07 D02D02D02D02 W05W05W05W05 W07W07 EXISTING WINDOW EXISTING WINDOW 3' 8' CRAW SPACE KITCHENCLOSET F1 D-0 F1 D-0 F1 D-0 F1 D-0 PROPOSED 10" CONCRETE FOUNDATION WALL ON 24" X 12" CONTINUOUS CONCRETE FTG. 3000 PSI CONCRETE MIN. BOTTOM OF FTG ON UNDISTURBED SOIL. W1 D-0 W1 D-0 PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH ELECTRICAL PANEL GARBAGE DISPOSAL SWITCH LIGHTINGCO/SMOKE DETECTOR PROPOSED EXTERIOR WALL: - WEATHER-RESISTANT BARRIER OVER SHEATHING - 1/2" CDX PLYWOOD SHEATHING - 2X6 SPF #2 STUDS @ 16" OC - CAVITY INSULATION R-20 MIN + R-5 CONTINUOUS EXTERIOR INSULATION - 1/2" GYPSUM BOARD INTERIOR FINISH W1 D-0 W1 D-0 CONSTRUCTION CEILING · 1/2" GYPSUM BOARD (GWB) · 1X3 WOOD STRAPPING · CEILING JOIST @ 16" O.C. · R-49 INSULATION BETWEEN JOISTS · VAPOR BARRIER (IF REQUIRED BY CLIMATE ZONE) · CEILING FINISH TO MATCH COLOR AND MATERIAL OF LIVING ROOM CEILING FL1 D-0 FL1 D-0 ROOF CONSTRUCTION – IRC 2021 & 780 CMR COMPLIANT -ASPHALT SHINGLES OVER 1 LAYER OF APPROVED UNDERLAYMENT (IRC R905.2), -INSTALLED ON 5/8" CDX PLYWOOD SHEATHING (IRC R803). - 2"X10" RAFTERS @ 16" O.C., WITH SIMPSON H2.5A HURRICANE TIES (IRC R802.11) AND RAFTER HANGERS WHERE REQUIRED. - 2"X12" RIDGE BOARD WITH FULL BEARING SUPPORT (IRC R802.3). - ATTIC INSULATION R-49 MINIMUM (IRC N1102.1.3, CZ 5 – MASSACHUSETTS). - 1"X3" WOOD STRAPPING FOR CEILING SYSTEM. - 1/2" GWB CEILING FINISH (IRC R702.3). - ROOF PITCH 3:12. SD/R2 D-0 SD/R2 D-0 2X10" @16 O.C ROOF RAFTERSCT1/CT2 D-0 CT1/CT2 D-0 COLLAR TIE (2X6) W2 D-0 W2 D-0 PROPOSED INTERIOR WALL: - 2" x 4" SPF #2 STUDS @ 16" OC - CAVITY INSULATION: R-13 MIN (WHERE REQUIRED) - 1/2" GYPSUM BOARD (BOTH SIDES) LIGHTINGLIGHTING HALL ELECTRIC RANGE OUTLET JOIST RIM BOARD 2" x 12 CONSTRUCTION FIRST FLOOR: FLOOR ASSEMBLY: FLOOR FINISH 3/4" T&G PLYWOOD SUBFLOOR JOIST @16" O.C. WITH R-30 INSULATION AIR-SEALING OF THE FLOOR ASSEMBLY TO PREVENT TEMPERATURE AND AIR TRANSFER DOUBLE OUTLET SWITCH DOUBLE OUTLET 2x 8" CEILING JOISTS @ 16" O.C. 2X10" FLOOR JOISTS @ 16" O.C. D02D02D02D02 W05W05W05W05 W07W07 EXISTING WINDOW EXISTING WINDOW 30" 36" 14" 32" 36" 40" 28"26" KITCHEN LIGHTING LIGHTING DOUBLE OUTLET DOUBLE OUTLET 30" 67" 36" 26" LIVING KITCHEN DOUBLE OUTLET DOUBLE OUTLET DOUBLE SWITCH LIGHTING LIGHTING LIGHTING BEDROOM DOUBLE OUTLETDOUBLE OUTLET PROPOSED MINI-SPLIT LIGHTING 42" 32" 28 1/2" LAUNDRY LIGHTING EXHAUST 36" 30" 21" 30" BATH VANITY LIGHTING EXHAUST DOUBLE OUTLET SHOWER PROPOSED NICHE 96" 26" 10" SHOWERLINEN LIGHT SHEET: SCALE: DATE: 12/18/2025 A-10 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY INDICATED PROPOSED CROSS SECTION - S1 SCALE: 1/4" = 1'-0" PROPOSED CROSS SECTIONS PROPOSED INTERIOR ELEVATIONS PROPOSED INTERIOR ELEVATION - IE1 SCALE: 1/2" = 1'-0" PROPOSED CROSS SECTION - S2 SCALE: 1/4" = 1'-0" PROPOSED CROSS SECTION - S3 SCALE: 1/4" = 1'-0" PROPOSED INTERIOR ELEVATION - IE2 SCALE: 1/2" = 1'-0" PROPOSED INTERIOR ELEVATION - IE3 SCALE: 1/2" = 1'-0" PROPOSED INTERIOR ELEVATION - IE4 SCALE: 1/2" = 1'-0" PROPOSED INTERIOR ELEVATION - IE5 SCALE: 1/2" = 1'-0" PROPOSED INTERIOR ELEVATION - IE6 SCALE: 1/2" = 1'-0" SHEET: SCALE: DATE: 12/18/2025 A-11 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY ILLUSTRATIVE IMAGES ILLUSTRATIVE IMAGES NO SCALE NO SCALE For SI: 1 inch = 25.4 mm RD - RIDGE DETAIL 06 - FOUNDATION CONNECTION SHEET: SCALE: DATE: 12/18/2025 A-12 PROJECT ADDRESS: 17 LINCOLN RD. SALEM, MA THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY DETAILS D-0 W1 - EXTERIOR WALL ASSEMBLY SD - SOFFIT DETAIL WF1 - FIRE RESISTANCE WALLW2 - INTERIOR WALL CT1 - COLLAR TIE DISTANCE X=2/3 THE RAFTER LENGTH CT2 - COLLAR TIE (1) LAYER 5/8'' GWB, PTD CON'T VAPOR RETARDER 2X6 WOOD STUDS AT 16'' O.C. CAVITY INSULATION R-20 MIN 1/2'' CDX PLWD SHEATHING CON'T AIR AND WATER BARRIER EXTERIOR SIDING U-RATING: U-0.044 MAX SIM UL U408 R-5 CONTINUOUS EXTERIOR INSULATION RL1 - CONNECTION TO BUILDING SO - SONOTUBE DETAIL MC - METAL CONNECTOR OPTIONS FOR WOOD STRUCTURES FL1 - FLOOR DETAIL LF1 - LEDGER FASTENER SPACING NOTES 1 CONTRACTOR IS RESPONSIBLE TO VERIFY IN FIELD ALL TRIM DETAILS, IN THE CASE OF ANY DISCREPANCIES CONTACT DESIGNER IMMEDIATELY. 2 ALL TRIM IS TO BE APPLIED w/ STAINLESS STEEL FINISH NAILS 3 NAIL HOLES TO BE FILLED AND SANDED w/ BONDO 4 ALL CELLULAR PVC TRIM TO BE WIPED DOWN WITH DENATURED ALCOHOL IMMEDIATELY PRIOR TO PAINTING. ALL TRIM TO RECEIVE TWO COATS MINIMUM 100% ACRYLIC PAINT. DURATION FROM SHERWIN WILLIAMS OR APPROVED EQUAL. 5 TO RECEIVE PRIMER AND TWO COATS OF FINISH PAINT. TO BE APPROVED BY OWNER. 6 CONTRACTOR RESPONSIBLE FOR FLASHING DETAILS. 7 WATER, VAPOR BARRIER F1 - CRAW SPACE FOUNDATION F2 - FOUNDATION CONNECTION CONSTRUCTION FIRST FLOOR: FLOOR ASSEMBLY: FLOOR FINISH 3/4" T&G PLYWOOD SUBFLOOR JOIST @16" O.C. WITH R-30 INSULATION AIR-SEALING OF THE FLOOR ASSEMBLY TO PREVENT TEMPERATURE AND AIR TRANSFER B1 - (BEAM DETAIL) BP - BEAM POCKETS 6X6 PT POST