12-18 FRONT STREET - BUILDING INSPECTION { 12-.18 FRONT STREET n 0Y,. I wug of 'Stttem, assarljusetts dire Ocpartttuni Bradgaarirra February 6. 1975 James F. Brennan, Chief Rel J, J. Welch & Sons Salem Fire Dept. . Front St. Restoration Sirs 12-16-Front Street As a result of an inspection conducted at 2190 P.M. this date of the above construction area, the following recommendations are made which will be in the interest of fire prevention and required to comply with the code prior to certification by this office. 1. It is to be noted for the record that this office was requested at the Noon hour to make an inspection of this new restoration area for an approval of same. While it is our policy due to a lack of experienced specialists in this office, to request an appointment for said inspections at least 48 hours in advance, I did provide this inspection on short notice, because I was told it would create a hardship on the developers if not done immediately. and the work was completed. 2. Upon inspection I found the following work was not done as noted$ a. Sprinkler systems 1. No notice for proper test has been received from the installer. This is a requirement of the various codes. 2. The plans were approved on Dec. 17, 1974, which it shallbe noted was long after the construction began. 3. Upon inspection I find no electric bell in place for sprinkler alarm notification. ( The water motor gong requirement has been eliminated as a deviation rec_uest for aesthetic reasons. ) 4. The fire department connection appears in proper order, but no test could be madeq because of advance notice lacking and it was found that an opening was still existing on this supply line in the basement. This would have flodded the basement if used. 3. The supply side pressure gage on the O. S, & Y valve was not working because it lacked a plug on the piping. 6. No pressure gage is installed at the inspectors pipe on the third floor. This shall be installed on the system side of the valve to show the static pressure at the high p6int and the residual pressure upon a flow test. This shall be a per- manant part of the system. 7' In the center stairwell between the second and third floor, one sprinkler head was installed at a point directly in the path of the partition. This necessitated the sheet rock being _gut out which left an opening in the wall and will also make the head deficient in operation. 8. It is also to be noted that the sprinklers are to remain behind the lowered ceiling tiles. This was not approved as part of the installation by this office. The subsequent samples submitted to this office latter in the afternoon i Inspection report of Welch Properties 12-18 Front St. Page #2. 8i ..Continued: were manufactured by Preferred Plastics Inc. and the data sheets attached did not show this product to have an under- writer of factory mutual approval for use below sprinklers. Upon further investigation in my office I can not find this company or product listed as approved in my copies of the Building Materials Directory, This material to be .acceptable under sprinklerso must therefore be certified by some testing labatory in writing for acceptance by this office, 3. It has been found that the stairways to the third floor are open from the second floor and it is hereby requested of the building inspector to check for proper classification of the stairwell doors. $. As of this date certain areas have been occupied prior to approval. i On the first floor a clothing shop has occupied one section. On the second floor a suite has been occupied by an attorneys office and also an architect and others. 5. Carpeting has been installed in the second floor corridors and the offices as well as the Hardiman dress shop, without any certification as to the flame spread and smoke contribution. . Said certification shall be made by the installers of the carpeting as required by code. 6. An appointment has been made with Mr. Vini Amanti to re-inspect for approval the sprinkler systemo at 200 P.M. on Monday Feb. 4 log 1975. 7. The Boiler room door is off its hinges and no emergency lights exist. Re pectf ly subm' tted, ` ieut. David J. / ogg' " I Salem Fire Mars. al ccs Building Insp. Powers Mayor Jean A. Levesque J.J. Welch & Sons. City Electrician Condon. Itnama Associates Inc. WOODMAN INSURANCE AGENCY, INC. 221 ESSEX STREET SALEM, MASSACHUSETTS 01970 )—(l EDWARD R.CARROL:L -e1cphone EDWARD R.C:ARROU-JR. ?+ 7442557 October 25 , 1983 ON 26 1983 SALEM PLANNING DEPT. I Mr. Greg Senko Planning Board , City of Salem "`' One Salem Green Salem, MA 01970 Q, �ii�l� . ✓ Re: Toy Emporium Co. LTD 1 11rt10` r,0- Bond #06S86093BCA & v U Bond #06S86111BCA � Dear Mr. Senko: 0 The above has been out of business for some time. Would you kindly respond releasing the City's interest in the two Sign Permit Bonds mentioned above. This will allow us to process cancellation of these bonds. Thank you for your cooperation. Sincerely, WOODMAN INSURANCE AGENCY, INC. Edward R. Carroll, Jr. ERCj COMMONWEALTHOF MASSACHUSETTS CITY/` @Wi- OF S A L E M APPLICATION FOR CERTIFICATE OF INSPECTION Date 7-5-79 ( ) Fee Required (Amount ) ( ) No Fee Required In accordance with the provisions of the Massachusetts State Building Code , Section 108 ,15 , I hereby apply for a Certificate of Inspection for . the below-named premises located at the following address : Street and Number 24 Front Street Name of Premises Kate Hardiman Purpose for Which Premises is Used women' s apparel License( s ) or Permit ( s ) Required for the Premises by Other Governmental Agencies : License or Permit Agency , Certificate to be Issued to Kate Hardiman Address 24 Front Street, Salem, MA Owner 'of Record of Building Welch Family Trust Address 8 Front Street, Salem MA Name of Present Holder of Certificate same Name of Agent , if any SIGNATURE OF PERSON TO WHOM TITLE CERTIFICATE IS ISSUED OR HIS AUTHORIZED AGENT DATE INSTRUCTIONS : 1 ) Make check payable to : CITY OF SALEM 2 ) Return this application with your check to : John B. Powers, Inspector of Buildings, City Hall Annex, One Salem Green, Salem, Massachusetts 01970 PLEASE NOTE : 1 ) Application form with accompanying fee must be submitted for each build- ing or structure or part thereof to be certified. 2 ) Application and fee must be received before the certificate will be issued . 3 )' The building official shall be notified within ten ( 10) days of any change in the above information. CERTIFICATE N EXPIRATION DATE : FORM SBCC-3-74 PERIODIC INSPECTION INFORMATION SHEET Instructions: This information sheet is not an inspection checklist. Each time a permanent file card is typed for a new building or a new card for an old build- ing, this information sheet can be prepared by the building inspector as a work sheet from which the file card can be typed. The items of information on this sheet are identical to the items on the file card. If all the information on this sheet cannot be entered on the file card, this sheet should be filled out and not discarded. Street and Number 24 Front Street Name of Premises Kate Hardiman Other Licenses or Permits Required NONE Owner of Record of Building Welch Family Trust Address 8 Front Street, Salem, MA Certificate to be Issued to Kate Hardiman Address Use Group Classification Purpose Used woman's apparel Public or privateublic Number of Stories 3 Class of Construction woodDate Erected 1850 Certified Capacity (By Story or Type) Number of Rooms - Hospitals, Schools, Hotels (By Story or Type) Number of Dwelling Units Per Story NONE Emergency Lighting System WET Means of Detecting and Extinguishing Fire Sprinkler System Fire Alarm System through Automatic Sprinkler Number of Elevators NONE How Heated forced hot water Boiler or Other Heating Apparatus boiler How Lighted gas How Ventilated flue Place of Assembly: Yes—No X Purpose Used Commercial In Which Story first Standard Booth Installed Location Fixed Seating NONE Number of Aisles and Width of Each Fire Resistance of Curtains or Draperies Number of Sanitaries 1 Location Adiacent Number of Grade Floor Means of Egress Doorways two Number of Separate Stairways Accessible Per Story three Number of Approved Independent Exitways Per Story, three Remarks: Date Certificate Issued Date Certificate Expires Date Orders Issued Date Orders Complied Inspector Date FORM SBCC-1-74 1 • w�T,.coew,�t e 6p��u OF FA^F u�♦'�+rruc ca�� ��Uri O tnpa CITY OF SALEM HEALTH DEPARTMENT U `l7 $aIeBOARD MassaOchuset�ts 011970 CITY of.. L`r AC {d SS ' ROBERT E. BLENKHORN 9 NORTH STREET HEALTH AGENT August 7, 1987 (617) 741-1800 Ms. Deborah Spillane Copley Investments / Suite 417 (6/ One Salem Green I Salem, MA 01970 I�' Dear Ms. Spillane, This letter is a clearification of the July 27, 1987 Building Inspector's Department correspondence (see enclosed) . On Friday July 24, 1987 Robert E. Blenkhorn, Health Agent, and William Burke, R.S. , met with a member of the building Inspector's Office for a site assessment of the airconditioning unit located on Front Street. Mr. Blenkhorn stated that the noise was not ex- cessive; however, the large fan was not operating during the time of ob- servation. The Health Department requests anon site meeting with you and any other individuals you feel necessary to get the whole scope of the problem. The Health Department appreciates your cooperation in this matter. If you have any questions feel free to contact this office. at 741-1800. FOR THE BOARD OF HEALTH t' R0OB E. BLENKHORN, C.H.O. HEALTH AGENT cc: Building Inspector's Office Lenard O'Leary, Councillor Steve Jepsky, 20 Central Street, Apt. 408, Salem, MA 01970 Alfred Cicconi, 10 Newbury Street, Boston, MA 02116 Ctu of Gam. 3 �ublir Properfu Pepartuieut rl' uillitiq epurtmetlt (nnr nlrm (4rern 743-0213 William H. Munroe Director of Public Property Maurice M. Martineau, Asst Inspector Inspector of Buildings Edgar J. Paquin, Asst Inspector Zoning Enforcement Officer John L. LeClerc, Plumbing/Gas Insp. July 27, 1987 Dc �� EAUG 6 1987 Leonard F. O'Leary, President City Council Ll . t OF SALEM 93 Washington St. HEALTH DEPT. Salem, MA 01970 A RE: Central Plaza Dear Councillor O'Leary: In response to the attached Order this Department, accompanied by Robert E. Blenkhorn, Health Agent, investigated the complaint. ' In Mr. BlenkhornIs professional opinion the-noise emitted by this unit does not constitute noise polution and the complaint would not appear to be inforceable. Respectfully, William H. Munroe Director of Public Property WHM:bms cc: Ms. Deborah Spillane Copley Investments i Suite 417. One Salem Green I. Enclosure: ( 1 ) i CERTIFICATE DATA EXPIRES ISSUED CERTIFICATE NO. INSPECTOR Change Usel 6 2/80 48-80 Mansur Occupancy '- ' ORDERS • ISSUED COMPLIED ISSUED COMPLIED 19 19 19 19 19 19 19 19 19 19 19 19 REMARKS STREET & NUMBER 16 Front St. DATE OTHER LICENSES OR PERMITS REQUIRED OWNER OF RECORD OF BUILDING Welch Family Trust ADDRESS 8 Front St. , Salem, MA. CERTIPICATE ISSUED TO Toy Emporium Company Ltd. ADDRESS 16 Front St. , Salem, MA NAME OR ADDRESS I JAN FEB MARAPR MAY JUN I JUL JAUG SEP OCT NOV DEC USE YEAR 16 Front St. (The Toy Emporium Co. , Ltd.) M 80 P 16 Front Street (Toy Emporium Co, Ltd.) I M 80 -1 NAME OR ADDRESS I JANI FEOMAqAPRIMAY[JUNIJULl AU SEP OCT NI OEC USE YEAR PURPOSE USED toy store PROVIDE THE FOLLOWING INFORMATION AS APPLICABLE # OF STORIES 3 CLASS OF CONSTRUCTION masonry wood DATE ERECTED 18550 CERTIFIED CAPACITY: (BY STORY OR TYPE) Toy Store-30-First Floor NUMBER OF ROOMS - HOSPITALS, SCHOOLS, HOTELS: (BY STORY OR TYPE) NUMBER OF DWELLING UNITS PER STORY • FORM SBCC-274 • EMERGENCY LIGHTING SYSTEM WET MEANS OF DETECTING AND EXTINGUISHING FIRE Sprinkler System # OF ELEVATORS NONE HOW HEATED forced hot water BOILER OR OTHER HEATING APPARATUS boiler HOW LIGHTED gas HOW VENTILATED flue PLACE OF ASSEMBLY: YES NO X PURPOSE USED IN WHICH STORY first STANDARD BOOTH INSTALLED LOCATION FIXED SEATING NONE # OF AISLES AND WIDTH FIRE RESISTANCE OF CURTAINS OR DRAPERIES # OF SANITARIES 1 LOCATION Adjacent # OF GRADE FLOOR MEANS OF EGRESS DOORWAYS two # OF SEPARATE STAIRWAYS ACCESSIBLE PER STORY three # OF APPROVED INDEPENDENT EXITWAYS PER STORY tree Vilols Associates Arcnilecis/Planners !230 Sailer Office Building -- 20slon, MA 02115 617-482-!990 - 7 Q n!t f V. Victors Vitcls. AIA U Liviu Brill. Ala Marquis G. Major, AIA CII; Bailey S. Silbert, AIA orif'�O' William B. Fitzpatrick In Mellon H. Martin Stockman Hirosm Yoneyama October 14 , 1987 THE WELCH GROUP , INC . 15 Front Street Salem, MA 01970 ATTENTION : Bob Cervone Al Valley Dear Sirs: Enclosed please find a letter from Rona Associates outlining their suggestions regarding structural issues on Essex Court,,specifically column base plate repairs , cold weather concreting and structural steel inspection. These last two issues are addressed in detail in the Specifications , under Division 3 and 5 respectively. As far as the base plate repairs are concerned, these should be undertaken as soon as possible, before further loads are applied, and ought to be completed - subject to the approval of the Architect and Engineer - before any concrete slabs are poured on the Essex Street building. Please forward your proposals for repair to me and to Rona Associates as soon as possible . If you have any further questions regarding these matters , please let me know. Sincerely , VITOLS ASSOCIATES Denise Carcia CC: Richard Ness Stanley Sidney Rona Associates Bill Monroe , Building Inspector Thomas Rona Associates, Inc. Consulting Engineers Thomas S. Rona 711 Boylston Street Roger J. Hobeika Boston. Massachusetts 02116 Karl A.Anderson (617) 536--9800 October 9 , 1987 Vitols Associates , Architects/Planners 1230 Statler Office Building Boston, MA. 02116 Attn: Ms . Denise Garcia Dear Denise : This letter adresses structural issues outstanding as of October 7 , 1987 . 1) Grout at column base plates : under ,no_ circumstances should the -thickness,-of-grout-under-said base. plates exceed the �3/4' specified in-.�:dr_aw,� gs . In the future, The Welch Group should have sufficient leveling plates at the site to use in compensation of errors of elevations of tops of footings . For_ hbase plates already�set[on—more than 3/4" of grout-an on wd hiccolumns have been erected,tThe_Welcti Group is re- quested-to -submit proposals fon reDairlsub7ect to the ap- '. proval of the architect and the engineer. 2) Cold Weather Concreting: the project specifications , divi- sion 3, section 03310 treats procedures for pouring conn- crete in cold weather conditions . Said section generally refers to ACI Code requirements . 3) Structural_,Steel Inspection: uality control of structural steel is treated _qted in division 5 , section 015120 . More , 1 specifically, moment connections should be tested as per Massachusetts Building Code requirements using ultrasonic testing. Bolted connections should-be_tested according to .the latest edition of the -AISC-Code as specified- in- the chapter -entitled Strutural Joints Using ASTM A325-_or. �—A490 Bolts _ I trust these issues are now resolved to your satisfaction. Should you have further inquiry, please inform me as soon as possible . Respectfully, irmando Castro AC/ac ARCHITECT ' S SITE INSPECTION REPORT PROJECT: Essex Court Condominium, Salem, MA ARCHITECT: Vitols Associates CLIENT/OWNER: Essex Court Development Corp. CONTRACTOR: The Welch Group OFFICE NUMBER: 8631 DATE: 10/14/87 INSPECTED BY: Denise Garcia ATTENDING : Richard Ness, Stanley Sidney, Victor Vitols , Elliott Steinberg , Bob Cervone , Al Valley, Armando Castro WEATHER CONDITIONS : Sunny, 60 ' s EQUIPMENT ON SITE: One steel erection crane OBSERVATIONS : 1 . Last 3 '-0 " portion of strip footing @ 5-line adjacent to elevator #2 - unsuitable fill beneath has been chased out. Concrete to be poured (Friday) to within 3 " of bottom of footing and remaining cavity packed with grout. 2 . Well point system on around pump chamber in courtyard - re-excavation to begin when water table has dropped sufficiently (el . 2 '-0 " - 3 '-0 " ) . Elliot Steinberg to supervise stabilizing of footing @ D-12 and resetting of pump chamber to proper elevation. 3 . Steel erection: structural steel up to 5th level on Essex St. building . Bar joists tack welded to level 2 , and metal decking in place. 4 . Underslab drainage system - PVC piping being installed in last portion of link building , to approximately P-line. SIGNED : COPIES TO: Richard Ness , Real Estate Development Group, Inc. Bill Monroe, Salem Building Department VITOLS ASSOCIATES 482-1990