December 4 , 1987
Al Valley
THE WELCH GROUP
15 Front Street
Salem, MA 01970
Dear Al:
As per your request I have contacted City officials
concerning two issues in the Essex Court Project:
_ a) fire treated blocking requirements, and b) pool
drain line tie-ins. Regarding the first issue, Mr.
Bill Monroe of the Salem Building Department
informed me that we will need fire-treated blocking
only at the townhouse elevation along the 23 line,
at all openings and behind any trimwork. Other than
this area, the remainder of the project does not
require fire-treated blocking.
Regarding the second issue, Mr . Dennis Ross
(Plumbing Inspector) informed me that pool drain
line tie-ins will have to be made to storm lines
either at Church Street or in the courtyard. Bob
Carter of H . W. Moore confirmed this possibility and
suggested a tie-in be made to the courtyard drainage
system as this precludes the need for an additional
sump. An SK will be generated and forwarded to you
as soon as possible showing this new condition.
Sincerely,
VITOLS ASSOCIATES
Denise Carcia
cc: Richard Ness, Development Group
William Monroe, Building Inspector, City of Salem
Dennis Ross, Plumbing Inspector, City of Salem
fit# ofttlem, tt�s�zcl#use##s
ff4rr Irpwamrnt Fr0quurtrrs
Tames X- Armmm
QIhief
June 20, 1974
John Powers
Building Inspector Rei Front St. Property
City of Salem J. J. Welch, Owner
Five Broad street
Salem, Mass. 01970
Sirs
As provided for in the Salem Fire Code, I have this date reviewed
project plans for the proposed Front Street Property Development.
The following recommendations are hereby made in the interest of
fire prevention and/or to correct conditions that are or may become
dangerous as a fire hazard or are in violation of law.
1.Plan R-2s Second floor plan-Bldg. R-6 section-It appears that
the door to the hall leading to the third floor opens inward, and
should open outward in the direction of egress.
2. Plan R-2s Second floor plan-Bldg. R-8 section-It appears that the
door to the hall leading to the third floor opens inward, and should
open outward in the direction of egress.
3.Plan R-2s First floor plan-Bldgs. R-6 and R-8 sections-It appears
that both basement stairway doors at top of stairs open into base-
ment and should open outward in direction of egress.
4. 2taxxRxkxxkixs:txftmnzxpixRxBj:r;gxxkiiaxsm:tim"xi txappxaxaxt
:tkaxi2aaxmtRftxttfaixxjtXxtdmmxxnplxxxinxxxtxmiixa3amxttxmpaanxmn:tw a"
iRx6tft*1t*ilaj1xfafx*gltlamx. Voided.
5. Plan R-2s First floor plan-Bldg R-8 section-Four rear egress
doors open inward and should open in direction of egress.
6. Plan R-3s Third floor plan-Bldg. R-6 section-It appears that the
stairway door down opens inward to third floor and .should open
in the direction of egress.
7. Plan R-3s Basement floor plan-Bldgs. R-6 and R-8 sections- It
appears that both basement stairway doors open inward and should
open in direction of egress.
8. Plan R-6s First floor plan-Bldg. R-6 section-Same as Item #3.
9. Plan R-7s Second floor plan-Bldg. R-6 section-Item #1 above has
been corrected in this plan.
,10. Plan R-6s First floor plan-Bldg. R-6 section-Front doors shown
opening inward, and different than shown on Plan R-2. Your atten-
tion is called to note concerning occupancy load.
Page #2-Front Street Property (J. J. Welch, Owner)
11. Plan R-13s First floor. plan-Bldg. R-8 section-All four rear doors
appear to open inward, and should open in the direction of egress.
12. Plan H-Iii Basement floor plan- It shall be noted that the
boiler room shall conform to all pertinent provisions for enclosure
in commercial structures.
13. It shall be noted that all air conditioning and duct work shall
comply fully with the conditions as set forth in N.F.P.A. Standard
# 90A as to installation and fire protection.
14. This structure being used as a three story occupancy shall comply
completely with the provisions of Section 7A1`tYa 7A2 of the Salem
Fire code, relating to installation of Sprinklers and fire alarm
equipment. As of this date no plans have been submitted to the
Fire Prevention Bureau for approval as per Section 8 of the Salem
Fire Code.
;R a
Lieut. David J. G gin
Salem Fire Marshal
cc% James H. Ballou. A. I.A.
J.J. Welch, owner
prJiL:�1NC f��f'�
��a 9
�p`l �
RrCENEOff SS.
CItY 0V SAI
aCANCELLATION NOTICE THE (ETNA CASUALTY AND SURETY COMPANY
THE STANDARD FIRE INSURANCE COMPANY
UFE&CA,SUALT Hartford, Connecticut 06115
Office at Boston
Date August 7 1985
CERTnUED MAIL - RETURN RBCEM REWWrM
F
City of Salem 1 Mob 6 C
City Rall
Salem, Massachusetts
You are hereby notified that this Company elects to cancel:
a) Individual Bond No.
covering
(Name & Address)
Goo& Bond or Policy No. nF s An%nM James J. Welsh & Co., 15 Front Streetr Salem, P
r
❑ c) Coverage under Bond or Policy No.
insofar as the acts of are concerned.
❑ d) Insuring Agreement(s) of Policy No.
This cancellation is to take effect on the
7th day of Oct
ober 1Y .1,,,198E
in accordance with the terms of said Bond or Policy. 1•: .•