GENERAL CERTIFICATE OF CONFORMITY
Contains:WG1048E2,WG1048E2BLK,WG1048E2GR, or WG1048E2DGR
Description: 8" Round Suction Outlet Cover
rSafety
ngs: Open Area, 8.1 Sf1-111 ETheCover and Sump combination are rated at
ollowing Maximum Allowable Flow Rates
ied to Comply with Section 1404 of the Ulrginia Graeme Baker Act(VGB)Pool&Spa Port Floor Mounted 116 GPM
at on by Act freports dated Jied at 16 CFR part 1450,when uly 2019 and/or installed
2020n the listed and Ma chp2009 is below.
2"Bottom Port Floor-Mounted 123 GPM
Manufactured.After Oct 1,2020,by a Division of Hayward Industries,Inc.at K4-A,214028 - Side Port Wall-Mounted I 66 GPM
Block K4-A,Export Processing Zone Wuxi New District Jiangsu Province PRO 214028,
China; or at One Hayward Industrial Drive,Clemmons,NO 27012. 2"Bottom Port Wall-Mounted 59 GPM
-------------
Certified by Hayward Industries 1415 Vantage Park Dr, ,Suite 400 Charlotte,NO 28203 1 1/2"Side Port Floor-Mounted 107 GPM
Phone 908-355-7995.Contact at www.hayward-pool.com 1 1/2"Side Port Wall-Mounted 72 GPM
Record Custodian is Customer Service at www,hayward-pool.com. 1 1/2"Bottom Port Floor-Mounted 122 GPM
Email: https://www.hayward-pool.com/shop/en/pools/contactForm 1 1/2"Bottom Port Wall-Mounted 64 GPM
Hayward Pool Products P.O.Box 5100 Clemmons, NO 27012-5100, Phone:908-355-7995
To our customers,the Serial Number is a 17 digit number,preceded by letters"SN".The Serial#Code:21121005456789001
•First 2 digits are"21",conforming to UCC-128 symbology,signifying a serial#
*The 3rd—4th digits are the manufacturing"plant"code (12 for Clemmons,21 for Wuxi,China)
•The 5th—8th are"year&month"of the date of manufacture and assembly
*The 9th—17th are"unique serialized number"for each product
Tested to: t.Tested by NSF
Road,Ann Arbor,MI 481113,Phone Section 1404 34-769-8010 in 201 the i8 Virginia
a:http:///nfo n f..org/Certified/Po to sL ist ngs.asp?Company International,21600 789 Dixboro
Date of Installation;
Suction outlet components have a finite life,the cover/grate as well as the hardware shall be inspected frequently and replaced at least every 7 years from
the date of installation,or if found to be damaged, broken,cracked,missing,or not securely attached.If the cover/grate cannot be securely attached into
the sump, a replacement insert kit WG1048EKIT,with instructions, is available. If this kit fails to allow the cover to be securely attached,the sump shall
be replaced.
Hayward Pool Products acknowledges that it is a federal crime to knowingly and willingly make materially false,fictitious,or fraudulent statements,repre-
sentations,or omissions on this certification.
SVCnt9nget ies USED ON THE FOLLOWING SERIES �� mhpY I A�]P.I
AND NO OTHER: 1,
WG1030
61411
WG1048
WG1049
WG1051
N"dia. � WG1052
Suction outletr3k ! WG1053
cover WG1048E — ;
WG1054
Ta.®� v 1
'� WG1153
WG1154
lk
A Warning - Suction Entrapment Hazard
Suction in suction outlets and/or suction outlet covers which are installed in a small area and/or below the surrounding surface can cause severe injury
or death due to body entrapment hazard.
To reduce the risk of body entrapment,installation of the field fabricated sumps must be such that the top of the mounted cover is a minimum of 1 1/2"
above the finished pool surface over an area larger than 40"on a diagonal.