10 BARNES AVENUE TITLE V INSPECTION REPORT 4-28-26
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 1 of 19
Inspection results must be submitted on this form. Inspection forms may not be altered in any way. Please see
completeness checklist at the end of the form.
A. Inspector Information
1. Inspector:
Nicholas Geneseo
Name of Inspector
Wind River Environmental
Company Name
46 Lizotte Drive Suite 1000
Company Address
Marlborough MA 01752
City/Town State Zip Code
508-233-0552 SI 13988
Telephone Number License Number
B. Certification
I certify that: I am a DEP approved system inspector in full compliance with Section 15.3 40 of Title 5 (310 CMR
15.000); I have personally inspected the sewage disposal system at the property address listed above; the information
reported below is true, accurate and complete as of the time of my inspection; and the inspection was performed
based on my training and experience in the proper function and maintenance of on-site sewage disposal systems.
After conducting this inspection I have determined that the system:
Passes
Conditionally Passes
Needs Further Evaluation by the Local Approving Authority
Fails
Apr 28, 2026
Inspector's Signature Date
The system inspector shall submit a copy of this inspection report to the Approving Authority (Board of Health or
DEP) within 30 days of completing this inspection. If the system has a design flow of 10,000 gpd or greater, the
inspector and the system owner shall submit the report to the appropriate regional office of the DEP. The original
should be sent to the system owner and copies sent to the buyer, if appl icable, and the approving authority.
Please note: This report only describes conditions at the time of inspection and under the conditions of
use at that time. This inspection does not address how the system will perform in the future under the
same or different conditions of use.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 2 of 19
C. Inspection summary
Inspection Summary: Complete 1, 2, 3, or 5 and all of 4 and 6.
1) System Passes:
I have not found any information which indicates that any of the failure criteria described
in 310 CMR 15.303 or in 310 CMR 15.304 exist. Any failure criteria not evaluated are indicated below.
Comments:
2) System Conditionally Passes:
One or more system components as described in the "Conditional Pass" section need to be replaced
or repaired. The system, upon completion of the replacement or repair, as approved by the Board of
Health, will pass
Check the box for "yes", "no" or "not determined" (Y, N, ND) for the following statements. If "not
determined," please explain.
The septic tank is metal and over 20 years old* or the septic tank (whether metal or not) is structurally unsound,
exhibits substantial infiltration or exfiltration or tank failure is imminent. System will pass inspection if the
existing tank is replaced with a complying septic tank as approved by the Board of Health.
* A metal septic tank will pass inspection if it is structurally sound, not leaking and if a Certificate of
Compliance indicating that the tank is less than 20 years old is available.
Y N ND (Explain below)
The system is working as designed at this time.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 3 of 19
C. Inspection summary (cont.)
2) System Conditionally Passes (cont.):
Pump Chamber pumps/alarms not operational. System will pass with Board of Health approval if
pumps/alarms are repaired.
Observation of sewage backup or break out or high static water level in the distribution box due to
broken or obstructed pipe(s) or due to a broken, settled or uneven distribution box. System will pass
inspection if (with approval of Board of Health):
broken pipe(s) are replaced Y N ND (Explain below):
obstruction is removed Y N ND (Explain below):
distribution box is leveled or replaced Y N ND (Explain below):
The system required pumping more than 4 times a year due to broken or obstructed pipe(s). The system
will pass inspection if (with approval of the Board of Health):
broken pipe(s) are replaced Y N ND (Explain below):
obstruction is removed Y N ND (Explain below):
3) Further Evaluation is Required by the Board of Health:
Conditions exist which require further evaluation by the Board of Health in order to determine if the
system is failing to protect public health, safety or the environment.
a. System will pass unless Board of Health determines in accordance with 310 CMR 15.303(1)(b) that the
system is not functioning in a manner which will protect public health, safety and the environment:
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 4 of 19
C. Inspection summary (cont.)
Cesspool or privy is within 50 feet of a surface water
Cesspool or privy is within 50 feet of a bordering vegetated wetland or a salt marsh
b. System will fail unless the Board of Health (and Public Water Supplier, if any) determines that the
system is functioning in a manner that protects the public health, safety and environment:
The system has a septic tank and soil absorption system (SAS) and the SAS is within 100 feet of a surface
water supply or tributary to a surface water supply.
The system has a septic tank and SAS and the SAS is within a Zone 1 of a public water supply.
The system has a septic tank and SAS and the SAS is within 50 feet of a private water supply well.
The system has a septic tank and SAS and the SAS is less than 100 feet but 50 feet or more from a private
water supply well**.
Method used to determine distance:
** This system passes if the well water analysis, performed at a DEP certified laboratory, for fecal coliform
bacteria indicates absent and the presence of ammonia nitrogen and nitrate nitrogen is equal to or less than 5
ppm, provided that no other failure criteria are triggered. A copy of the analysis must be attached to this form.
c. Other:
4) System Failure Criteria Applicable to All Systems:
You must indicate "Yes" or "No" to each of the following for all inspections:
Yes No
Backup of sewage into facility or system component due to overloaded or clogged SAS
or cesspool
Discharge or ponding of effluent to the surface of the ground or surface waters due to
an overloaded or clogged SAS or cesspool
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 5 of 19
C. Inspection summary (cont.)
4) System Failure Criteria Applicable to All Systems: (cont.)
Yes No
Static liquid level in the distribution box above outlet invert due to an overloaded or
clogged SAS or cesspool
Liquid depth in cesspool is less than 6" below invert or available volume is less than ½
day flow
Required pumping more than 4 times in the last year NOT due to clogged or obstructed
pipe(s). Number of times pumped:
Any portion of the SAS, cesspool or privy is below high ground water elevation.
Any portion of cesspool or privy is within 100 feet of a surface water supply or tributary
to a surface water supply.
Any portion of a cesspool or privy is within a Zone 1 of a public well.
Any portion of a cesspool or privy is within 50 feet of a private water supply well.
Any portion of a cesspool or privy is less than 100 feet but greater than 50 feet from a
private water supply well with no acceptable water quality analysis. [This
system passes if the well water analysis, performed at a DEP certified laboratory,
for fecal coliform bacteria indicates absent and the presence of ammonia
nitrogen and nitrate nitrogen is equal to or less than 5 ppm, provided that no
other failure criteria are triggered. A copy of the analysis and chain of custody
must be attached to this form.]
The system is a cesspool serving a facility with a design flow of 2000gpd -10,000gpd.
The system fails. I have determined that one or more of the above failure criteria exist
as described in 310 CMR 15.303, therefore the system fails. The system owner should
contact the Board of Health to determine what will be necessary to correct the failure.
5) Large Systems: To be considered a large system the system must serve a facility with a design flow of
10,000 gpd to 15,000 gpd.
For large systems, you must indicate either "yes" or "no" to each of the following, in addition to the questions in
Section C.4.
Yes No
the system is within 400 feet of a surface drinking water supply
the system is within 200 feet of a tributary to a surface drinking water supply
the system is located in a nitrogen sensitive area (Interim Wellhead Protection Area -
IWPA) or a mapped Zone II of a public water supply well
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 6 of 19
C. Inspection summary (cont.)
If you have answered "yes" to any question in Section C.5 the system is considered a significant threat, or
answered "yes" in Section C.4 above the large system has failed. The owner or operator of any large system
considered a significant threat under Section C.5 or failed under Section C.4 shall upgrade the system in
accordance with 310 CMR 15.304. The system owner should contact the appropriate regional office of the
Department.
6. You must indicate "yes" or "no" for each of the following for all inspections:
Yes No
Pumping information was provided by the owner, occupant, or Board of Health
Were any of the system components pumped out in the previous two weeks?
Has the system received normal flows in the previous two week period?
Have large volumes of water been introduced to the system recently or as part of this
inspection?
N/A Were as built plans of the system obtained and examined? (If they were not available
note as N/A)
Was the facility or dwelling inspected for signs of sewage back up?
Was the site inspected for signs of break out?
Were all system components, excluding the SAS, located on site?
Were the septic tank manholes uncovered, opened, and the interior of the tank
inspected for the condition of the baffles or tees, material of construction, dimensions,
depth of liquid, depth of sludge and depth of scum?
Was the facility owner (and occupants if different from owner) provided with information
on the proper maintenance of subsurface sewage disposal systems? The size and
location of the Soil Absorption System (SAS) on the site has been determined
based on:
Existing information. For example, a plan at the Board of Health.
Determined in the field (if any of the failure criteria related to Part C is at issue
approximation of distance is unacceptable) [310 CMR 15.302(5)]
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 7 of 19
D. System Information
1. Residential Flow Conditions:
Number of bedrooms (design): 3 Number of bedrooms (actual): 3
DESIGN flow based on 310 CMR 15.203 (for example: 110 gpd x # of bedrooms): 330
Description:
Number of current residents: 2
Does residence have a garbage grinder? Yes No
Does residence have a water treatment unit? Yes No
If yes, discharges to:
Is laundry on a separate sewage system? (Include laundry system inspection
information in this report.)
Yes No
Laundry system inspected? Yes No
Seasonal use? Yes No
Water meter readings, if available (last 2 years usage (gpd)): 73 gpd
Detail:
Sump pump? Yes No
Last date of occupancy: Currently occupied
Date
Used last two years water records. Water Consumption Report from the town is attached on Page 18.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 8 of 19
D. System Information (cont.)
2. Commercial/Industrial Flow Conditions:
Type of Establishment:
Design flow (based on 310 CMR 15.203):
Gallons per day (gpd)
Basis of design flow (seats/persons/sq.ft., etc.):
Grease trap present? Yes No
Water treatment unit present? Yes No
If yes, discharges to
Industrial waste holding tank present? Yes No
Non-sanitary waste discharged to the Title 5 system? Yes No
Water meter readings, if available:
Last date of occupancy/use:
Date
Other (describe below):
General Information
3. Pumping Records:
Source of information: The homeowner and Wind River Environmental are the sources of
the information. Last pump out by Wind River Environmental was
4/6/2026.
Was system pumped as part of the inspection? Yes No
If yes, volume pumped:
gallons
How was quantity pumped determined?
Reason for pumping:
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 9 of 19
D. System Information (cont.)
4. Type of System:
Septic tank, distribution box, soil absorption system
Single cesspool
Overflow cesspool
Privy
Shared system (yes or no) (if yes, attach previous inspection records, if any)
Innovative/Alternative technology. Attach a copy of the current operation and maintenance
contract (to be obtained from system owner) and a copy of latest inspection of the I/A system by
system operator under contract
Tight tank. Attach a copy of the DEP approval.
Other (describe):
Approximate age of all components, date installed (if known) and so urce of information:
Tank and SAS 1979, the distribution box 2019
Were sewage odors detected when arriving at the site? Yes No
5. Building Sewer (locate on site plan):
Depth below grade: 1.5
feet
Material of construction:
cast iron 40 PVC other (explain):
Distance from private water supply well or suction line: N/A
feet
Comments (on condition of joints, venting, evidence of leakage, etc.):
Building sewer is clear with good flow and no leaks or obstructions.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 10 of 19
D. System Information (cont.)
6. Septic Tank (locate on site plan):
Depth below grade: 0.8
feet
Material of construction:
concrete metal fiberglass polyethylene other (explain)
If tank is metal, list age:
years
Is age confirmed by a Certificate of Compliance? (attach a copy of certificate) Yes No
Dimensions: 8’x5’x4’
Sludge depth: 7”
Distance from top of sludge to bottom of outlet tee or baffle 29”
Scum thickness 1”
Distance from top of scum to top of outlet tee or baffle 5”
Distance from bottom of scum to bottom of outlet tee or baffle 15”
How were dimensions determined? Tape measure
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels
as related to outlet invert, evidence of leakage, etc.):
Liquid level is normal with a filter and risers installed to grade. The tank still appears to be in good condition with
no leaks or concrete loss. Recommend cleaning the filter and pumping annually.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 11 of 19
D. System Information (cont.)
7. Grease Trap (locate on site plan):
Depth below grade:
feet
Material of construction:
concrete metal fiberglass polyethylene other (explain):
Dimensions:
Scum thickness
Distance from top of scum to top of outlet tee or baffle
Distance from bottom of scum to bottom of outlet tee or baffle
Date of last pumping:
Date
Comments (on pumping recommendations, inlet and outlet tee or baffle condition, structural integrity, liquid levels
as related to outlet invert, evidence of leakage, etc.):
8. Tight or Holding Tank (tank must be pumped at time of inspection) (locate on site plan):
Depth below grade:
Material of construction:
concrete metal fiberglass polyethylene other (explain):
Dimensions:
Capacity:
gallons
Design Flow:
gallons per day
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 12 of 19
D. System Information (cont.)
8. Tight or Holding Tank (cont.)
Alarm present: Yes No
Alarm level: Alarm in working order: Yes No
Date of last pumping:
Date
Comments (condition of alarm and float switches, etc.):
* Attach copy of current pumping contract (required). Is copy attached? Yes No
9. Distribution Box (if present must be opened) (locate on site plan):
Depth of liquid level above outlet invert 0
Comments (note if box is level and distribution to outlets equal, any evidence of solids carryover, any evidence of
leakage into or out of box, etc.):
Three outlet distribution box was replaced in 2019 and riser installed to grade. The box is watertight and level
with equal distribution. No runback is present and there is minimal carryover.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 13 of 19
D. System Information (cont.)
10. Pump Chamber (locate on site plan):
Pumps in working order: Yes No*
Alarms in working order: Yes No*
Comments (note condition of pump chamber, condition of pumps and appurtenances, etc .):
* If pumps or alarms are not in working order, system is a conditional pass.
11. Soil Absorption System (SAS) (locate on site plan, excavation not required):
If SAS not located, explain why:
Type:
leaching pits number:
leaching chambers number:
leaching galleries number:
leaching trenches number, length: 3, 38’ each
leaching fields number, dimensions:
overflow cesspool number:
innovative/alternative system
Type/name of technology:
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 14 of 19
D. System Information (cont.)
11. Soil Absorption System (SAS)(Cont.)
Comments (note condition of soil, signs of hydraulic failure, level of ponding, damp soil, condition of vegetation,
etc.):
12. Cesspools (cesspool must be pumped as part of inspection) (locate on site plan):
Number and configuration
Depth - top of liquid to inlet invert
Depth of solids layer
Depth of scum layer
Dimensions of cesspool
Materials of construction
Indication of groundwater inflow Yes No
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.):
There was no evidence of hydraulic failure at the time of this inspection. No breakout or overgrowth was
observed. Ran a scope out each trench and found no ponding.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 15 of 19
D. System Information (cont.)
13. Privy (locate on site plan):
Materials of construction:
Dimensions
Depth of solids
Comments (note condition of soil, signs of hydraulic failure, level of ponding, condition of vegetation, etc.):
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 16 of 19
D. System Information (cont.)
14. Sketch Of Sewage Disposal System:
Provide a view of the sewage disposal system, including ties to at least two permanent reference landmarks or
benchmarks. Locate all wells within 100 feet. Locate where public water supply enters the building. Check one of
the boxes below:
hand-sketch in the area below
drawing attached separately
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 17 of 19
D. System Information (cont.)
15. Site Exam:
Check Slope
Surface water
Check cellar
Shallow wells
Estimated depth to high ground water: 6’
feet
Please indicate all methods used to determine the high ground water elevation:
Obtained from system design plans on record
If checked, date of design plan reviewed:
Date
Observed site (abutting property/observation hole within 150 feet of SAS)
Checked with local Board of Health - explain:
Checked with local excavators, installers - (attach documentation)
Accessed USGS database - explain:
You must describe how you established the high ground water elevation:
Before filing this Inspection Report, please see Report Completeness Checklist on next page.
Dug a hole to a depth of 6’ off the edge of the property with no water or dampness.
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 18 of 19
E. Report Completeness Checklist
Complete all applicable sections of this form inclusive of:
A. Inspection information: Complete all fields in this section.
B. Certification: Signed & Dated and 1, 2, 3, or 4 checked
C. Inspection Summary:
1, 2, 3, or 5 completed as appropriate
4 (Failure Criteria) and 6 (Checklist) completed
D. System Information:
For 8: Tight/Holding Tank - Pumping contract attached
For 15: Sketch of Sewage Disposal System drawn on pg. 16 or attached
For 16: Explanation of estimated depth to high groundwater included
Water Consumption Report
Owner
information is
required for every
page.
Commonwealth of Massachusetts
Title 5 Official Inspection Form
Subsurface Sewage Disposal System Form - Not for Voluntary Assessments
Property Address
Maria Evelyn Torigian
Owner's Name
Salem MA 01970 Apr 28, 2026
City/Town State Zip Code Date of Inspection
10 Barnes Avenue
t5ins.doc rev. 7/26/2018 Title 5 Official Inspection Form: Subsurface Sewage Disposal System Page 19 of 19