PB_Hawthorne Boulevard 13 - architectural plans (dates added) - 2020.02.13CONSULTANT TITLE:
CONSULTANT TITLE:
CONSULTANT TITLE:
MECHANICAL, PLUMBING, ELECTRICAL & FIRE PROTECTION ENGINEER:
CIVIL ENGINEER:
STRUCTURAL ENGINEER:
PROJECT TEAM:
LOCUS MAP:
OWNER/DEVELOPER:
ARCHITECT:
PL
O
T
T
E
D
O
N
:
ISSUE DATE:
ICON ARCHITECTURE
101 Summer Street, Boston, MA 02110
617.451.3333
2/
1
2
/
2
0
2
0
3
:
5
6
:
3
8
P
M
13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
FEBRUARY 13, 2020
NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.
SITE PLAN REVIEW
NORTH SHORE COMMUNITY DEVELOPMENT COALITION
96 LAFAYETTE STREET, SALEM, MA 01970
LIM CONSULTANTS, INC
6 PLEASANT ST, MALDEN, MA 02148
NITSCH ENGINEERING, INC
2 CENTER PLZ #430, BOSTON, MA 02108
WOZNY BARBAR & ASSOCIATES, INC
1076 WASHINGTON ST, HANOVER, MA 02339
VHB
99 HIGH ST #10, BOSTON, MA 02110
IRWIN ENGINEERS INC
33 W CENTRAL ST, NATICK, MA 01760
X
X
?
21
2
1
20
19
19
18
17
15
16
17
1
5
16
19
1
8
1
7
16
17
17
17
18
1
8
roof
drain
roof
drain
roof
drain
UTILITY
POLE
2" pipe-capped
Water-3"
Electric
Gas
1-1/2" COPPER
CITY NOTES
wood fence
X X X X X X X
X
X
X
X
X
X
X
X
X
iron fence
GG GG
GENERAL NOTES
1. WITHIN CLASSROOMS:
A. ALL EXISTING MILLWORK, INCLUDING BUT NOT LIMITED TO, WAINSCOT, FLOOR
BASE, CHALKBOARD RAILS, CHALKBOARDS, SCOTIA MOULDING, AND EXISTING
DOORS AND TRIM, TO BE REMOVED,CATALOGUED, AND PROTECTED, TO BE
REINSTALLED IN SELECT LOCATIONS AS HIGHLIGHTED.
B. ALL EXISTING MILLWORK CABINETS TO BE REMOVED, CATALOGUED &
PROTECTED, TO BE RESTORED & REINSTALLED, WHERE POSSIBLE, IN SELECT
LOCATIONS AS HIGHLIGHTED.
C. EXISTING CLASSROOM BUILT-IN CABINETRY TO BE RETAINED WHERE POSSIBLE
D. EXISTING CLASSROOM CHALKBOARDS & RAILS TO BE REINSTALLED IN LIVING
ROOM & BEDROOM SPACES WHERE POSSIBLE.
E. ITEMS NOT REINSTALLED ARE TO BE RETURNED TO OWNER.
F. EXISTING CLASSROOM WALLS TO BE RETAINED WHERE POSSIBLE.
G. EXISTING HARWOOD FLOORS TO BE RETAINED & REFINISHED WHERE POSSIBLE.
2. WITHIN CORRIDORS:
A. WAINSCOT IN HALLWAY TO REMAIN AND BE RESTORED.
B. EXISTING WOOD HANDRAILS & MILLWORK AT STAIR TO BE RESTORED.
C. EXISTING DOOR TRIM AT HALLWAY SIDE OF DOORS TO REMAIN AND BE
RESTORED.
D. EXISTING PLASTER AT WALLS TO REMAIN.
E. HISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN
POSITION, TYP.
3. REFER TO ENLARGE UNIT PLANS FOR TYPICAL APPROACH FOR UNIT LAYOUTS
4. EXISTING DOORS TO BE STORED ON SITE FOR DETERMINATION ON HISTORICAL
SIGNIFICANCE.
LEGEND
AREA OF FLOOR INFILL
AREA OF HISTORIC TRIM
AREA OF HISTORIC CHALK
BOARDS & RAILS
A-201
2
A-201
1
ACCESSIBLE ROUTE
774 SF
1BR
G05
470 SF
ST
G18
835 SF
2BR
G11
660 SF
1BR
G10
675 SF
1BR
G09
648 SF
1BR
G04
675 SF
1BR
G03
666 SF
1BR
G02
656 SF
1BR
G01
473 SF
STUDIO
G08
495 SF
STUDIO
G07
7' - 11 1/8"
UNASSIGNED
UNASSIGNED
REMOVE EXISTING CONCRETE LOADING DOCK
INFILL EXISTING BOILER ROOM FLOOR TO MEET
CORRIDOR ELEVATION
INFILL EXISTING GYMNASIUM FLOOR TO MEET
CORRIDOR ELEVATION
NEW RESILIENT FLOORING AT CORRIDORS
EXPOSED BLOCK TO BE RETAINED &
REFINISHED, TYP
INFILL EXISTING OPENING TO PROVIDE UNIT SEPARATION;
REMOVE EXISTING DOOR HARDWARE, DOOR & FRAME.
HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION
ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL
WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO
BE RETAINED/REINSTALLED WHERE POSSIBLE.
AREA OF RAMP & STAIR ABOVE
NEW WINDOW WELL
DEMO EXISTING EXT STAIR & DOOR BELOW;
PROVIDE NEW WINDOW & WINDOW WELL
EXISTING STAIR TO BE REMOVED
DEMO EXISTING EXT STAIR & DOOR BELOW;
PROVIDE NEW WINDOW & WINDOW WELL
LONG TERM
BIKE STORAGE
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
1
0
P
M
A-101
GARDEN LEVEL PLAN13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
4'0 8'16'
NO
R
T
H
MARK DATE DESCRIPTION
?
21
21
2
1
20
19
19
18
15
16
17
1
5
16
19
1
8
1
7
16
17
16
17
17
18
1
8
1
9
20
wood fence
X X X X X X X
X
X
X
X
X
X
X
X
X
X
X
X
c
h
a
i
n
l
i
n
k
f
e
n
c
e
iron fence
U
N
I
O
N
S
T
R
E
E
T
GG GG
DOUBLE HEIGHT
STAGE
683 SF
1BR
101
665 SF
1BR
102
1001 SF
2BR
106
654 SF
1BR
104
675 SF
1BR
103
251 SF
MANAGEMENT
G001A
REMOVE EXISTING CONCRETE LOADING DOCK
REMOVE RETROFIT INFILL AT HISTORIC MASONRY OPENINGS
TO ACCOMODATE NEW WINDOW & DOOR SYSTEMS
NEW RAMP FROM ACCESSIBLE PARKING TO SECONDARY ENTRY
INFILL EXISTING OPENING TO PROVIDE UNIT SEPARATION; REMOVE
EXISTING DOOR HARDWARE, DOOR & FRAME. HISTORIC DOOR TO BE
FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/
RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM &
HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.
REMOVE EXISTING RETROFIT DOOR & TRANSOM ASSEMBLY; PROVIDE
NEW GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING RETROFIT DOOR AND PARTITIONS; PROVIDE NEW
GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL
CONFIGURATIONS PER ORIG. DWGS, TYP
NEW RESILIENT FLOORING AT CORRIDORS
HISTORIC CLASSROOM ENTRY DOORS TO BE
RETAINED & FIXED IN OPEN POSITION, TYP.
HISTORIC TRIM [INC WAINSCOT, FLOOR
BASE, CHALK RAILS, SCOTIA MOULDINGS]
TO BE RETAINED & RESTORED AS
HIGHLIGHTED, TYP
REMOVE EXISTING RETROFIT DOOR &
TRANSOM ASSEMBLY; PROVIDE NEW GLAZED
METAL DOOR SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS,
TYP.
EXISTING WOOD FLOORING AT AUDITORIUM AND
STAGE TO BE RETAINED & RESTORED. PROTECT
DURING DEMO & CONSTRUCTION.
INFILL EXISTING OPENING TO PROVIDE UNIT SEPARATION; REMOVE
EXISTING DOOR HARDWARE, DOOR & FRAME. HISTORIC DOOR TO BE
FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/
RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM &
HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.
REMOVE EXISTING RETROFIT DOOR & TRANSOM ASSEMBLY; PROVIDE
NEW GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
PROTECT & MAINTAIN EXISTING CORRIDOR
DOOR & GLAZING SYSTEM
REMOVE EXISTING RETROFIT DOOR & TRANSOM ASSEMBLY; PROVIDE
NEW GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP. (BOTH SIDES)
U
U
U
U
U
U
EXISTING CLASROOM BUILT-IN CASEWORK
TO BE RETAINED WHERE POSSIBLE
HISTORIC TRIM [INC WAINSCOT, FLOOR BASE,
CHALK RAILS, SOCITA MOULDINGS] TO BE
RETAINED & RESTORED AS HIGHLIGHTED, TYP.
LINE OF EXISTING
BALCONY OVERHEAD
DOUBLE
HEIGHT
HA
W
T
H
O
R
N
E
B
L
V
D
A-201
2
A-201
1
A-202.
3
P
PROTECT & MAINTAIN BULLETIN BOARD CASES
IN CORRIDORS WHERE POSSIBLE, TYP
RES
ENTRY
PUBLIC
ENTRY
LOBBY
ACCESSIBLE
ROUTE
3509 SF
NON-RESIDENTIAL
G001
WC WC
726 SF
1BR
105
RAMP DOWN
RAMP DOWN
RA
M
P
DO
W
N
NEW WINDOW WELL
DEMO EXISTING EXT STAIR &
DOOR BELOW; PROVIDE NEW
WINDOW & WINDOW WELL
EXISTING STAIR TO BE REMOVED
DEMO EXISTING EXT STAIR & DOOR BELOW;
PROVIDE NEW WINDOW & WINDOW WELL
646 SF
NON-RESIDENTIAL
G001F
MAX OCC: 234
B IK E P A R K I N G
B
I
K
E
P
A
R
K
I
N
G
GENERAL NOTES
1. WITHIN CLASSROOMS:
A. ALL EXISTING MILLWORK, INCLUDING BUT NOT LIMITED TO, WAINSCOT, FLOOR
BASE, CHALKBOARD RAILS, CHALKBOARDS, SCOTIA MOULDING, AND EXISTING
DOORS AND TRIM, TO BE REMOVED,CATALOGUED, AND PROTECTED, TO BE
REINSTALLED IN SELECT LOCATIONS AS HIGHLIGHTED.
B. ALL EXISTING MILLWORK CABINETS TO BE REMOVED, CATALOGUED &
PROTECTED, TO BE RESTORED & REINSTALLED, WHERE POSSIBLE, IN SELECT
LOCATIONS AS HIGHLIGHTED.
C. EXISTING CLASSROOM BUILT-IN CABINETRY TO BE RETAINED WHERE POSSIBLE
D. EXISTING CLASSROOM CHALKBOARDS & RAILS TO BE REINSTALLED IN LIVING
ROOM & BEDROOM SPACES WHERE POSSIBLE.
E. ITEMS NOT REINSTALLED ARE TO BE RETURNED TO OWNER.
F. EXISTING CLASSROOM WALLS TO BE RETAINED WHERE POSSIBLE.
G. EXISTING HARWOOD FLOORS TO BE RETAINED & REFINISHED WHERE POSSIBLE.
2. WITHIN CORRIDORS:
A. WAINSCOT IN HALLWAY TO REMAIN AND BE RESTORED.
B. EXISTING WOOD HANDRAILS & MILLWORK AT STAIR TO BE RESTORED.
C. EXISTING DOOR TRIM AT HALLWAY SIDE OF DOORS TO REMAIN AND BE
RESTORED.
D. EXISTING PLASTER AT WALLS TO REMAIN.
E. HISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN
POSITION, TYP.
3. REFER TO ENLARGE UNIT PLANS FOR TYPICAL APPROACH FOR UNIT LAYOUTS
4. EXISTING DOORS TO BE STORED ON SITE FOR DETERMINATION ON HISTORICAL
SIGNIFICANCE.
LEGEND
AREA OF FLOOR INFILL
AREA OF HISTORIC TRIM
AREA OF HISTORIC CHALK
BOARDS & RAILS
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
1
4
P
M
A-102
FIRST FLOOR PLAN13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
1/8" = 1'-0"1 FIRST FLOOR PLAN
4'0 8'16'
NO
R
T
H
MARK DATE DESCRIPTION
DN
1001 SF
2BR
207
463 SF
STUDIO
202
685 SF
1BR
201
465 SF
STUDIO
203
653 SF
1BR
205
682 SF
1BR
204
927 SF
2BR
206
A-500
2BR
A-500
1BR
A-500
ST
CL OF BEAM OVERHEAD, VIF
INFILL EXISTING OPENING TO PROVIDE UNIT SEPARATION; REMOVE
EXISTING DOOR HARDWARE, DOOR & FRAME. HISTORIC DOOR TO BE
FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/
RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM &
HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.
NEW RESILIENT FLOORING AT
CORRIDORS
HISTORIC CLASSROOM ENTRY DOORS TO BE
RETAINED & FIXED IN OPEN POSITION, TYP.
HISTORIC TRIM [INC WAINSCOT, FLOOR
BASE, CHALK RAILS, SCOTIA MOULDINGS]
TO BE RETAINED & RESTORED AS
HIGHLIGHTED, TYP
INFILL EXISTING OPENING TO PROVIDE UNIT SEPARATION; REMOVE
EXISTING DOOR HARDWARE, DOOR & FRAME. HISTORIC DOOR TO BE
FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/
RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM &
HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.
PROTECT & MAINTAIN EXISTING CORRIDOR
DOOR & GLAZING SYSTEM
EXISTING CLASROOM BUILT-IN CASEWORK
TO BE RETAINED WHERE POSSIBLE, TYP
PROTECT & MAINTAIN EXISTING CORRIDOR
DOOR & GLAZING SYSTEM
HISTORIC CLASSROOM ENTRY DOORS TO
BE RETAINED & FIXED IN OPEN POSITION,
TYP. EXISTING DOOR TRIM AT CORRIDOR
SIDE OF DOORS TO BE RETAINED &
RESTORED, TYP
U
U
U
U
U
U
U
EXISTING CLASSROOM BUILT-IN CASEWORK
TO BE RETAINED WHERE POSSIBLE
EXISTING CLASROOM BUILT-IN CASEWORK
TO BE RETAINED WHERE POSSIBLE, TYP
EXISTING CLASROOM CHALK RAILS TO BE
REINSTALLED WHERE POSSIBLE
PROTECT, MAINTAIN & RESTORE EXISTING
HARDWOOD FLOORS AT CLASSROOMS WHERE
POSSIBLE, TYP
OPEN TO BELOW
UNASSIGNED
869 SF
NON-RESIDENTIAL
G001M
OPEN TO
BELOW
GENERAL NOTES
1. WITHIN CLASSROOMS:
A. ALL EXISTING MILLWORK, INCLUDING BUT NOT LIMITED TO, WAINSCOT, FLOOR
BASE, CHALKBOARD RAILS, CHALKBOARDS, SCOTIA MOULDING, AND EXISTING
DOORS AND TRIM, TO BE REMOVED,CATALOGUED, AND PROTECTED, TO BE
REINSTALLED IN SELECT LOCATIONS AS HIGHLIGHTED.
B. ALL EXISTING MILLWORK CABINETS TO BE REMOVED, CATALOGUED &
PROTECTED, TO BE RESTORED & REINSTALLED, WHERE POSSIBLE, IN SELECT
LOCATIONS AS HIGHLIGHTED.
C. EXISTING CLASSROOM BUILT-IN CABINETRY TO BE RETAINED WHERE POSSIBLE
D. EXISTING CLASSROOM CHALKBOARDS & RAILS TO BE REINSTALLED IN LIVING
ROOM & BEDROOM SPACES WHERE POSSIBLE.
E. ITEMS NOT REINSTALLED ARE TO BE RETURNED TO OWNER.
F. EXISTING CLASSROOM WALLS TO BE RETAINED WHERE POSSIBLE.
G. EXISTING HARWOOD FLOORS TO BE RETAINED & REFINISHED WHERE POSSIBLE.
2. WITHIN CORRIDORS:
A. WAINSCOT IN HALLWAY TO REMAIN AND BE RESTORED.
B. EXISTING WOOD HANDRAILS & MILLWORK AT STAIR TO BE RESTORED.
C. EXISTING DOOR TRIM AT HALLWAY SIDE OF DOORS TO REMAIN AND BE
RESTORED.
D. EXISTING PLASTER AT WALLS TO REMAIN.
E. HISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN
POSITION, TYP.
3. REFER TO ENLARGE UNIT PLANS FOR TYPICAL APPROACH FOR UNIT LAYOUTS
4. EXISTING DOORS TO BE STORED ON SITE FOR DETERMINATION ON HISTORICAL
SIGNIFICANCE.
LEGEND
AREA OF FLOOR INFILL
AREA OF HISTORIC TRIM
AREA OF HISTORIC CHALK
BOARDS & RAILS
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
1
8
P
M
A-103
SECOND FLOOR
PLAN13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
1/8" = 1'-0"1 SECOND FLOOR PLAN
4'0 8'16'
NO
R
T
H
MARK DATE DESCRIPTION
685 SF
1BR
301
463 SF
STUDIO
302
476 SF
STUDIO
303
680 SF
1BR
304
653 SF
1BR
305
INFILL EXISTING OPENING TO PROVIDE UNIT SEPARATION; REMOVE
EXISTING DOOR HARDWARE, DOOR & FRAME. HISTORIC DOOR TO BE
FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/
RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM &
HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.
NEW RESILIENT FLOORING AT CORRIDORS
HISTORIC CLASSROOM ENTRY DOORS TO BE
RETAINED & FIXED IN OPEN POSITION, TYP.
HISTORIC TRIM [INC WAINSCOT, FLOOR
BASE, CHALK RAILS, SCOTIA MOULDINGS]
TO BE RETAINED & RESTORED AS
HIGHLIGHTED, TYP
INFILL EXISTING OPENING TO PROVIDE UNIT SEPARATION; REMOVE
EXISTING DOOR HARDWARE, DOOR & FRAME. HISTORIC DOOR TO BE
FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/
RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM &
HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.
PROTECT & MAINTAIN EXISTING CORRIDOR
DOOR & GLAZING SYSTEM
EXISTING CLASROOM BUILT-IN CASEWORK
TO BE RETAINED WHERE POSSIBLE
PROTECT & MAINTAIN EXISTING CORRIDOR
DOOR & GLAZING SYSTEM
HISTORIC CLASSROOM ENTRY DOORS TO
BE RETAINED & FIXED IN OPEN POSITION,
TYP. EXISTING DOOR TRIM AT CORRIDOR
SIDE OF DOORS TO BE RETAINED &
RESTORED, TYP
EXISTING CLASROOM BUILT-IN CASEWORK
TO BE RETAINED WHERE POSSIBLE
U
U
U
U
U
A-201
2
A-201
1
A-202.
3
A-202.
4
PROTECT, MAINTAIN & RESTORE EXISTING
HARDWOOD FLOORS AT CLASSROOMS
WHERE POSSIBLE, TYP
GENERAL NOTES
1. WITHIN CLASSROOMS:
A. ALL EXISTING MILLWORK, INCLUDING BUT NOT LIMITED TO, WAINSCOT, FLOOR
BASE, CHALKBOARD RAILS, CHALKBOARDS, SCOTIA MOULDING, AND EXISTING
DOORS AND TRIM, TO BE REMOVED,CATALOGUED, AND PROTECTED, TO BE
REINSTALLED IN SELECT LOCATIONS AS HIGHLIGHTED.
B. ALL EXISTING MILLWORK CABINETS TO BE REMOVED, CATALOGUED &
PROTECTED, TO BE RESTORED & REINSTALLED, WHERE POSSIBLE, IN SELECT
LOCATIONS AS HIGHLIGHTED.
C. EXISTING CLASSROOM BUILT-IN CABINETRY TO BE RETAINED WHERE POSSIBLE
D. EXISTING CLASSROOM CHALKBOARDS & RAILS TO BE REINSTALLED IN LIVING
ROOM & BEDROOM SPACES WHERE POSSIBLE.
E. ITEMS NOT REINSTALLED ARE TO BE RETURNED TO OWNER.
F. EXISTING CLASSROOM WALLS TO BE RETAINED WHERE POSSIBLE.
G. EXISTING HARWOOD FLOORS TO BE RETAINED & REFINISHED WHERE POSSIBLE.
2. WITHIN CORRIDORS:
A. WAINSCOT IN HALLWAY TO REMAIN AND BE RESTORED.
B. EXISTING WOOD HANDRAILS & MILLWORK AT STAIR TO BE RESTORED.
C. EXISTING DOOR TRIM AT HALLWAY SIDE OF DOORS TO REMAIN AND BE
RESTORED.
D. EXISTING PLASTER AT WALLS TO REMAIN.
E. HISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN
POSITION, TYP.
3. REFER TO ENLARGE UNIT PLANS FOR TYPICAL APPROACH FOR UNIT LAYOUTS
4. EXISTING DOORS TO BE STORED ON SITE FOR DETERMINATION ON HISTORICAL
SIGNIFICANCE.
LEGEND
AREA OF FLOOR INFILL
AREA OF HISTORIC TRIM
AREA OF HISTORIC CHALK
BOARDS & RAILS
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
2
0
P
M
A-104
THIRD FLOOR PLAN13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
1/8" = 1'-0"1 THIRD FLOOR 4'0 8'16'
NO
R
T
H
MARK DATE DESCRIPTION
ROOF NOTES
- SLOPE CANNOT EXCEED 1" RISE MAX ACROSS CONDENSING UNITS
- ALL ROOF VENTS MUST BE SEPERATED BY AT LEAST 12" O.C.
- REMOVE ALL COPPER GUTTERS, CAPS & FLASHING THAT ARE CORRODED
OR DAMAGED BEYOND REPAIR.
ROOF BELOW
NEW ROOFTOP EQUIPMENT
OFFSET MIN 10'-0" FROM ROOF EDGE
EXISTING CAST STONE CAP W/
COPPER FLASHING, TYP. REFURBISH
WHERE POSSIBLE
EXISTING CAST STONE CAP W/
COPPER FLASHING, TYP.
REFURBISH WHERE POSSIBLE
RD
RD
REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP
EXISTING BRICK PARAPET W/
COPPER CAP & FLASHING, TYP;
REFURBISH WHERE POSSIBLE
EXISTING BRICK PARAPET W/
COPPER CAP & FLASHING, TYP;
REFURBISH WHERE POSSIBLE
EXISTING COPPER ROOF TO BE
REFURBISHED, WHERE POSSIBLE, TYP
EXISTING COPPER ROOFING AND FLASHING
TO BE REFURBISHED WHERE POSSIBLE, TYP
EXISTING COPPER CAP & FLASHING, TYP;
REFURBISH WHERE POSSIBLE
REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP
A-201
2
A-201
1
A-202.
3
A-202.
4
REMOVE EXISTING FLAT ROOFING
SYSTEM & PROVIDE NEW
MEMBRANE ROOF SYSTEM
REMOVE EXISTING FLAT ROOFING SYSTEM &
PROVIDE NEW MEMBRANE ROOF SYSTEM
EXISTING SLATE SHINGLE ROOF
TO BE REPAIRED IN KIND
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
2
2
P
M
A-105
ROOF PLAN13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
4'0 8'16'
NO
R
T
H
MARK DATE DESCRIPTION
FIRST FLOOR
24' -10"
SECOND FLOOR
37' -10"
GARDEN LEVEL
12' -10"
ROOF
64' -10"
THIRD FLOOR
50' -10"
CEILING
62' -4"
NEW CEILING
44' -7 3/4"
VI
F
11
'
-
6
"
VI
F
13
'
-
0
"
VI
F
13
'
-
0
"
VI
F
12
'
-
0
"
REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP
REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP
REMOVE EXISTING RETROFIT DOOR & TRANSOM
ASSEMBLY; PROVIDE NEW GLAZED METAL
DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL
CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
EXISTING COPPER FLASHING & GUTTERS TO REMAIN;
REFURBISH WHERE POSSIBLE
A-800
4
FRONT ENTRY
THRESHOLD
(SURVEY)
21' -4 143/256"
B.O. STAIR
(SURVEY)
17' -3 77/128"
FIRST FLOOR
24' -10"
SECOND FLOOR
37' -10"
GARDEN LEVEL
12' -10"
ROOF
64' -10"
THIRD FLOOR
50' -10"
CEILING
62' -4"
EXISTING
GYMNASIUM
FLOOR
7' -10"
NEW CEILING
44' -7 3/4"
VI
F
5'
-
0
"
VI
F
12
'
-
0
"
VI
F
13
'
-
0
"
VI
F
13
'
-
0
"
VI
F
11
'
-
6
"
NEW RAMP FROM ACCESSIBLE PARKING
TO SECONDARY ENTRY
REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP
REMOVE EXISTING RETROFIT DOOR & TRANSOM
ASSEMBLY; PROVIDE NEW GLAZED METAL
DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL
CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
EXISTING COPPER FLASHING & GUTTERS TO REMAIN;
REFURBISH WHERE POSSIBLE
EXISTING COPPER FLASHING & GUTTERS TO REMAIN;
REFURBISH WHERE POSSIBLE
REMOVE EXISTING WINDOW AND CASING TRIM,
CATALOGUE & STORE ONSITE, REFINISH & REINSTALL
IN LOCATION OF REMOVAL-TYP. REFERENCE
SPECIFICATIONS FOR REFINISHING PROCEDURES.
A-800B
1
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
2
7
P
M
A-201
BUILDING
ELEVATIONS13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
1/8" = 1'-0"2 PROPOSED - WEST ELEVATION
1/8" = 1'-0"1 PROPOSED - NORTH ELEVATION
2
1
4'0 8'16'
MARK DATE DESCRIPTION
FIRST FLOOR
24' -10"
FIRST FLOOR
24' -10"
SECOND FLOOR
37' -10"
GARDEN LEVEL
12' -10"
ROOF
64' -10"
THIRD FLOOR
50' -10"
CEILING
62' -4"
EXISTING
PLATFORM LEVEL
37' -4"
EXISTING
GYMNASIUM
FLOOR
7' -10"
3
A-500B
NEW CEILING
44' -7 3/4"
VI
F
11
'
-
6
"
VI
F
13
'
-
0
"
VI
F
13
'
-
0
"
VI
F
12
'
-
0
"
VI
F
12
'
-
6
"
VI
F
17
'
-
0
"
REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP
REMOVE EXISTING RETROFIT DOOR & TRANSOM
ASSEMBLY; PROVIDE NEW GLAZED METAL
DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL
CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
EXISTING COPPER FLASHING & GUTTERS TO REMAIN;
REFURBISH WHERE POSSIBLE
EXISTING COPPER FLASHING & GUTTERS TO REMAIN;
REFURBISH WHERE POSSIBLE
REMOVE EXISTING WINDOW AND CASING TRIM,
CATALOGUE & STORE ONSITE, REFINISH & REINSTALL
IN LOCATION OF REMOVAL-TYP. REFERENCE
SPECIFICATIONS FOR REFINISHING PROCEDURES.
REMOVE EXISTING RETROFIT DOOR & TRANSOM
ASSEMBLY; PROVIDE NEW GLAZED METAL
DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL
CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
REFERENCE SPECIFICATIONS FOR STONE
RESTORATION
A-800B
2
A-800B
1
Sim
EXISTING SLATE SHINGLE ROOF; REPAIR IN KIND
FIRST FLOOR
24' -10"
SECOND FLOOR
37' -10"
GARDEN LEVEL
12' -10"
ROOF
64' -10"
THIRD FLOOR
50' -10"
CEILING
62' -4"
EXISTING
GYMNASIUM
FLOOR
7' -10"
NEW CEILING
44' -7 3/4"
REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP
EXISTING COPPER FLASHING & GUTTERS TO REMAIN;
REFURBISH WHERE POSSIBLE
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
REMOVE EXISTING WINDOW SYSTEMS & FRAMES &
PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
3
4
P
M
A-202.
BUILDING
ELEVATIONS13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
4'0 8'16'
1/8" = 1'-0"3 PROPOSED- SOUTH ELEVATION
1/8" = 1'-0"4 PROPOSED - EAST ELEVATION
3
4
MARK DATE DESCRIPTION
ETR EXTERIOR WALL
REUSE EXISTING WINDOW
CASING OR MATCH EXISTING,
TYP
PT WD BLOCKING AS REQ'D
ETR STONE SILL, TYP; REF SPECS
FOR STONE RESTORATION
ETR EXTERIOR WALL
NEW JAMB FLASHING BYND
NEW ALUM WINDOW SYSTEM, TYP
MEETING RAIL
BRICK BEYOND
APPLIED MUNTIN
SPACER BAR AT APPLIED MUNTIN
APPLIED VERT MUNTIN BYND
APPLIED MUNTIN
SPACER BAR AT APPLIED MUNTIN
FILL VOIDS WITH LOW
EXPANDING FOAM INSUL (NEW)
NEW WD STOOL & APRON TO
MATCH EXISTING, TYP.
NEW JAMB FLASHING BYND
NEW SELF ADHERED
MEMBRANE FLASHING
NEW MTL SILL PAN FLASHING
W/ UPTURNED LEG
NEW ALUM PANNING
2
1
/
4
"
REVEAL WINDOW UNIT VARIES, VIF
INTERIOREXTERIOR
INTERIOR WINDOW SCREEN
INTERIOR WINDOW SCREEN
REINSTALL EXISTING TRIM OR
MATCH EXISTING, TYP
NEW PTD GWB, TYP.
NEW PT WD BLOCKING, TYP
NEW PTD GWB RETURN
REINSTALL EXISTING TRIM OR
MATCH EXISTING, TYPBRICK BEYOND
NEW PTD GWB RETURN
NEW PTD GWB RETURN
FILL VOIDS W/ LOW
EXPANSION FOAM INSUL
EXISTING STEEL LINTEL TO BE
PRIMED/PAINTED, AS REQ'D
VARIES
5"
.
13
/
1
6
"
5"
13
/
1
6
"
ETR STONE SILL & BANDING; REFERENCE
SPECIFICATIONS FOR STONE RESTORATION, TYP.
5' - 4" MO, VIF 1' - 8" VIF 11' - 0" MO, VIF
9'
-
1
3
/
8
"
M
O
,
V
I
F
5"
13
/
1
6
"
2
1
/
2
"
5"
5"13/16"5"13/16"
5"
13
/
1
6
"
2
1
/
2
"
5"
7"
EXISTING WOOD WINDOW REPLACEMENT SCOPE:
• REMOVE ALL EXT & INT SCREENS
• REMOVE ALL INFILL MATERIALS
• REMOVE EXISTING WINDOW, FRAME & TRIM; CATALOGUE & STORE TRIM ONSITE
• COORDINATE ALL PROCEDURES PER ENVIRONMENTAL CONSULTANT
• PROVIDE NEW WINDOW SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG DWGS, TYP
• REFINISH & REINSTALL EXISTING WINDOW TRIM IN LOCATION OF REMOVAL; OR MATCH EXISTING TYP
INTERIOREXTERIOR
5"
13
/
1
6
"
2
1
/
2
"
13
/
1
6
"
5"
VARIES
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
3
6
P
M
A-800
WINDOW DETAILS
REPLACEMENT -
HISTORIC APPROACH
13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
3" = 1'-0"2 PROPOSED
3/4" = 1'-0"4 WINDOW ELEVATIONS, TYP
3" = 1'-0"1 EXISTINGEXISTING CLASSROOM WINDOW TO BE REPLACED/REPLICATED, TYP
MARK DATE DESCRIPTION
EXISTING WOOD WINDOW RESTORATION SCOPE:
• REMOVE EXISTING WINDOW & CASING TRIM; CATALOGUE &
STORE ONSITE DURING DEMOLITION
• REMOVE EXISTING PAINT; COORDINATE ALL PROCEDURES
PER ENVIRONMENTAL CONSULTANT
• REGLAZE
• PROVIDE NEW HARDWARE INCLUDING POWER ASSIST
• PAINT AND REFINISH PER SPECIFICATIONS
• REINSTALL IN LOCATION OF REMOVAL
• PROVIDE NEW INTERIOR ENERGY STORMS
ETR STONE SILL; REFERENCE SPECIFICATIONS FOR
STONE RESTORATION, TYP.
10
'
-
3
"
,
V
I
F
VI
F
12
'
-
1
0
"
M
O
,
V
I
F
6' - 10" MO, VIF
5"13/16"
6"
2"
5"
.
EXISTING WOOD WINDOW REPLACEMENT SCOPE:
• REMOVE ALL EXT & INT SCREENS
• REMOVE ALL INFILL MATERIALS
• REMOVE EXISTING WINDOW, FRAME & TRIM;
CATALOGUE & STORE TRIM ONSITE
• COORDINATE ALL PROCEDURES PER
ENVIRONMENTAL CONSULTANT
• PROVIDE NEW WINDOW SYSTEM TO REPLICATE
ORIGINAL CONFIGURATIONS PER ORIG DWGS, TYP
• REFINISH & REINSTALL EXISTING WINDOW TRIM IN
LOCATION OF REMOVAL; OR MATCH EXISTING TYP3'
-
8
3
/
4
"
M
O
,
V
I
F
6' - 0" MO, VIF
3
3
/
4
"
13
/
1
6
"
1
3
/
4
"
1 3/4"13/16"
INTERIOREXTERIOR
2
3
/
4
"
13
/
1
6
"
3
3
/
4
"
INTERIOREXTERIOR
MASONRY BEYOND
NEW JAMB FLASHING BYND
FILL VOIDS W/ LOW
EXPANDING FOAM INSUL
NEW MTL SILL PAN FLASHING
W/ UPTURNED LEG
NEW ALUM PANNING
SAMF
ETR EXT WALL
APPLIED MUNTIN
VERT. APPLIED MUNTIN
SPACER BAR
NEW PT WD BLOCKING, TYP
SHIM AS REQ'D
ETR STONE SILL
INTERIOR WINDOW SCREEN
PAINT ETR RETURN
3
3
/
4
"
13
/
1
6
"
2
3
/
4
"
ETR EXT WALL
PT WD BLOCKING AS REQ'D
EXTR STEEL LINTEL TO BE
PRIMED/PAINTED, AS REQ'D
FILL VOIDS W/ LOW EXPANSION
FOAM INSUL
NEW ALUM WINDOW SYSTEM TYP
NEW JAMB FLASHING BYND
VERT. APPLIED MUNTIN
ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE
PROJECT NUMBER:
DRAWN BY:
CHECKED BY:
8/31/2018 MHC SUBMISSION
2/
1
2
/
2
0
2
0
3
:
5
6
:
3
8
P
M
A-800B
WINDOW DETAILS
RESTORATION -
HISTORIC APPROACH
13 HAWTHORNE BLVD
SALEM HISTORIC SCHOOLS
NORTH SHORE COMMUNITY DEVELOPMENT
COALITION, INC.218010.2
BD
Checker
3/4" = 1'-0"1 RESTORED WINDOW ELEVATION, TYP
EXISTING WOOD AUDITORIUM
WINDOW TO BE RESTORED, TYP
3/4" = 1'-0"2 REPLICATED WINDOW ELEVATION, TYP
3" = 1'-0"3
BASEMENT REPLACEMENT WINDOW
SECTION
MARK DATE DESCRIPTION