Loading...
126.5 Federal Street_CofNA_roofandskylightSalem Historical Commission 98 WASHINGTON STREET, SALEM, MASSACHUSETTS 01970 (978) 619-5685 CERTIFICATE OF NON-APPLICABILITY It is hereby certified that the Salem Historical Commission has determined that the proposed:  Construction  Moving x Reconstruction  Alteration  Demolition  Painting  Signage  Other Work as described below does not involve an exterior architectural feature or involves a feature covered by the exemptions or limitations set forth in the Historic District's Act (M.G.L. Ch. 40C) and the Salem Historic Districts Ordinance. District: McIntire Address of Property: 126 ½ Federal Street Name of Record Owner: Joy and Scott Marchand Davis Description of Work Proposed: Roof Replacement • Replace the water damaged and decaying roof over first-floor bay window o Water-damaged shingles are irreparable and must be replaced o No change in materials or design (red cedar shingles at a 5" exposure and clapboard) Skylight Replacement • Replace leaking skylight o Replace water damaged skylight with similar o Repair the adjacent clapboard and asphalt roofing to prevent further damage Not applicable due to being in-kind work or not visible from the public way. *NOTE: Historic materials and details must be retained and repaired except where material is not salvageable and must be replaced. If replacement is necessary, new elements must replicate existing details, dimensions and materials. Should any changes to materials, design or outward appearance be determined necessary, Applicant must submit a new application for review. Upon completion of the above work, please notify Historical Commission staff as final sign-off is required to document compliance with this Certificate and approved plans. Dated: March 11, 2026 SALEM HISTORICAL COMMISSION: By: The homeowner has the option not to commence the work (unless it relates to resolving an outstanding violation). All work commenced must be completed within one year from this date unless otherwise indicated. THIS IS NOT A BUILDING PERMIT. Please be sure to obtain the appropriate permits from the Inspector of Buildings (or any other necessary permits or approvals) prior to commencing work. Bay Window Exterior Bay Window Exterior Bay Window Exterior – View from Right Skylight Skylight View from Federal Street Skylight Interior View Skylight Interior View FS A21 Product Data Sheet Starting Production Code: 34AX08A Description General FS - Fixed Deck Mounted Skylight, consisting of the following integrated components – an interior condensation drainage gasket, pre-finished white wooden frame, exterior maintenance free aluminum cladding and counter flashing, corner keys, and a insulating thermal pane glass unit with two seals, warm edge spacer system, three coats of low e silver to increase visible light transmittance while reducing solar heat. Primary seal between glazing and cladding is a silicone based glazing sealant. And lastly, the skylights are mounted to the roof deck by fastening the continuous deck seal mounting system with durable foam seal directly to the roof deck. Variant FS xxx 200xB Installation Instructions Installation Instructions included in every box and are listed at www.VELUXusa.com or contact VELUX at 800-888-3589. Installation instructions provided with each unit. VAS 452197 Applications Single unit and combi applications. Orientation The skylight has a specific top and bottom and can not be rotated. Roof Pitch 0° - 10° Install with site built curb to elevate the pitch of the glass to 14 degrees. Then install a VELUX ECB counter flashing kit to create a water tight joint between the skylight and the site built curb. Drawings and instructions are available on the VELUXusa web site. 14° - 85° Mount the skylight directly to the roof deck by aligning and securing the continuous deck sealing mounting system direclty to the roof deck. Under 20° Condensation drippage from the pane interior can be expected. Compatibility Flashings EDL - single unit installation with thin roofing material (Shingles, Slates). EKL - side by side and or over and under combinations with thin roofing materials EDW - single unit installation with high (tile) profile roofing material EKW - side be side and or over and under combinations with high profiled (tile) roofing materials EDM - single unit installation with metal roofing panels. ECB - site build curb installations with roof pitch less than 14 degrees. Interior Accessories Manual & Electric - Blackout blinds, Roller blinds, Venetian Blinds. Solar - Blackout blinds, Roller blinds FS A21 Product Data Sheet Starting Production Code: 34AX08A Materials Wood Ponderosa pine finished white in the factory or as a special order, natural wood with a short term colorless wood perservative . Stain grade units are available as special order. Cladding Lacquered aluminum, neutral gray color with Kynar 500 top finish to prevent fading. 0.065mm thick. Copper - untreated mill finish. Special color cladding not available. Glazing Standard stocked glazing are type 04, 05, 06, 10. Contact VELUX for stocked sizes of 06 & 10 glazings. Consult with customer service for special glazing options and delivery. 05 - A LoE3 double sealed insulated panes filled with warm edge technology, stainless steel spacer, 95% Argon gas and coated with three layers of microscopic silver particles to increase thermal performance. This glazing in improved over prior in that it allow in more visible light while blocking out more solar heat gain (spectrally selective). Replaces type 75 comfort. Over all pane thickness is 17.2mm. 04 - LoE3 Laminated - All the benefits of the 05 LoE3 Glass plus a laminated interior pane for safety and maximum protection from both heat gain and fading with Neat coated exterior. Replaces type 74 Comfort Plus. Over all pane thickness is 17.6mm. Laminate 06 - Impact - Laminated heat strengthened with tempered LoE3 with Neat coated exterior. Over all pane thickness is 18.2mm. Laminate material is 0.90 PVB 08 - White laminated - Laminated heat strengthened with tempered LoE3. Same as 04 but a white inner layer. Over all pane thickness is 17.6mm. Laminate material is 0.30 PVB. 10 - Snow load - Laminated tempered with tempered LoE3 with Neat coated exterior. Over all pane thickness is 18.2mm. Laminate material is 0.30 Gaskets Patented engineered rubber gasket gaskets to prevent air infiltration and water penetration. Primary seal at glazing and cladding is silicone based glazing sealant. Deck Seal Mounting Flange Pre-engineered Deck Seal mounting system with a anti corrosive coating. The Deck Seal mounting system is pre- attached all the way around the perimeter of the skylight and has a durable closed cell foam that seals the skylight to the roof deck. Deck seal size: 1-1/4" up the frame and 1-1/4" away from the skylight frame. Flange attached to roof decking with 1-1/4" ring shank nails provided with skylight unit. FS A21 Product Data Sheet Starting Production Code: 34AX08A Sizes Standard Size A06, C01, C04, C06, C08, C12, D26, D06, M02, M04,M06, M08, S01 Special sizes Not available Special color Special color cladding not available Rough Opening Dimensions Size Width Size Height A06 14.1/2" D26 22 15/16" C01, C04, C06, C08 21" C01, S01 26 7/8" D25, D06 22 1/2" M02 30" M02, M04, M06, M08 30 1/16" C04, M04 37 7/8" S01, S06 44 1/4" A06 C06, D06, M06, S06 45 3/4" C08, M08 54 7/16" C12 70 1/4" Certification General Hallmark certified, Florida Product approval. Exceeds International Building Code (IBC), International Residential Code (IRC) and International Energy Conservation Code (IECC). Air, water, Structural WDMA Hallmark Certification. Architectural Testing Inc Code Compliant Research Report CCRR Thermal NFRC certified and labeled to Exceed Energy Star U-value and Solar Heat Gain (SHGC) requirements for all climate zones. Product Warranty Frame 10 years from the date of purchase, VELUX warrants that the skylight will be free from defects in material and workmanship Glass 20 years from the date of purchase, VELUX warrants that the insulated glass pane will not develop a material obstruction of vision due to a failure of the glass seal. Accessories 5 years from the date of purchase, VELUX warrants that VELUX blinds and control systems will be free from defects in material and workmanship. Installation 10 Years from the date of installation provided the skylight is installed with the three layers of protection per the manufactures instructions. Changes from Earlier Versions Exterior N/A Interior N/A Type Sign Example FS C06 2004 01AR05A Location Top left corner from out on the roof. Other Information Features & Benefits FS Tested Performance Information Glass Description (VELUX Glazing Code) Laminated (04) Impact (06) White- Laminated (08) Snowload (10) Laminated i89 (89) Thermal Performance (All listed thermal performance values are NFRC certified) U-Factor (Btu/hr·ft2·°F) 0.43 0.42 0.43 0.41 0.37 SHGC 0.23 0.24 0.23 0.24 0.23 VT 0.54 0.55 0.49 0.54 0.54 UV Protection % (300-380 nm) 99.9 99.9 99.9 99.9 99.9 Fading Protection % Krochmann Damage Function (300-600 nm) 83.1 84.6 88.4 83.2 85.1 Acoustical Ratings STC (Sound Transmission Class) 32 n.r. 32 n.r. 32 OITC (Outdoor-Indoor Transmission Class) 27 n.r. 27 n.r. 27 Certified Air Infiltration/Exfiltration CFM/ft2 0.01 0.02 0.01 0.11 0.01 Certified Water Resistance Lbs/ft2 15 15 15 15 15 Certified Structural Performance (lbs/ft2) Performance Grade or DP in accordance with AAMA/WDMA/CSA 101/I.S.2/A440-17 Tested Size Negative Design Pressure - Uplift (Hurricane) S06 70 50 70 65 70 M08 105 90 105 100 105 C06 n.r. n.r. n.r. 65 n.r. Tested Size Positive Design Pressure - Download (Snowload) S06 330 180 330 720 330 M08 240 200 240 640 240 C06 n.r. n.r. n.r. 1350 n.r. Fall Protection Testing Results Tested Size Testing is 200 lb sandbag dropped from indicated height to middle of glass without glass breakage. S06 1200 lbf-ft (6' drop) 1200 lbf-ft* (6' drop) 1200 lbf-ft* (6' drop) n.r. 1200 lbf-ft* (6' drop) M08 n.r. n.r. n.r. n.r. n.r. Wind-Borne Debris Impact Ratings for Impact (06) Glazing Tested Size Cycle Pressure (psf) Missile Level Maximum Wind Zone Florida Product Approval High Velocity Hurricane Zone S06 +/- 50 C 3 Yes No M08 +/- 50 C 3 Yes No 04 glass: Tempered with LoE 366 over clear laminated heat strengthened (0.030" interlayer) 06 glass: Tempered with LoE 366 over clear laminated heat strengthened (0.090" interlayer) 08 glass: Same as 04, with white interlayer 10 glass: Tempered with LoE 366 over clear laminated tempered (0.030" interlayer) 89 glass: Same as 04, with i89 coating on interior laminated surface * Indicates that the Laminated glass (04) test report should also cover this indicated glazing as it is equal to or stronger than the Laminated glazing n.r. = No report 3/28/2025