Loading...
95 Boston Street U2 Floor Plan and Elevation PlanAPPLICABLE CODES & REGULATIONS (9th EDITION 780 CMR) Applicable CodeCode Type 780 CMR: Massachusetts State Building Code -9th EditionMA Building 521 CMR: Massachursetts Architectural Access Board RegulationsAccessibility Plumbing As a reminder, the new, ninth edition code is based on modified versions of the following 2015 codes as published by the International Code Council (ICC). Residential International Residential Code 2015 (IRC 2015) Existing Buildings International Existing Building Code (IEBC) Energy International Energy Conservation Code (IECC) 248 CMR 10.00: Uniform State Plumbing Code PROJECT DESCRIPTION Design of an interior renovation of an existing condominium unit located at 95 Boston Street. Scope includes refresh of the kitchen, addition of a new full bath on the second floor and a new dormer on the third floor for a new full primary suite bathroom. PROJECT ZONING INFORMATION (LOCAL REGULATIONS) R2Property Class Parcel ID 15-0218-802 Neighborhood McIntire Zoning Ordinance Salem MA Zoning Ordinance Zoning Data Required Existing Proposed Use N/A units Residential # of Dwelling Units* 2 units 2 units Use & Lot 35 ftBuilding Height ETR ft ETR ft 15Front Yard Setback ETR ETRftft ft 30Rear Yard Setback ETR ETRftft ft 10Side Yard Setback (left) ETR ETRftft ft 10Side Yard Setback (right) ETR ETRftft ft 100Street Frontage ETR ETRftft ft Building Setbacks LOCUS MAP 95 BOSTON STREET, SALEM MA 34 3 M e d f o r d S t r e e t , S u i t e 4 C S o m e r v i l l e , M A 0 2 1 4 5 t: + 1 ( 6 1 7 ) 7 6 4 - 3 5 9 3 e: a s k j o e @ j o e t h e a r c h i t e c t . c o m ww w . j o e t h e a r c h i t e c t . c o m FOR PERMIT WARNING: This document may not be secure, may be corrupted in transmission or due to software incompatibility and/or may be amended or altered by third parties after leaving Joe The Architect LLC’s possession. Joe The Architect LLC is not responsible for and accepts no liability for such matters. Subject only to any conflicting provision within any prior binding agreement by Joe The Architect LLC (which agreement may also contain additional conditions relating to this document and its use): 1. the content of this document is confidential and copyright in it belongs to Joe The Architect LLC. They are permitted only to be opened, read and used by the addressee. 2. all users of this document must carry out all relevant investigations and must examine, take advice as required and satisfy themselves concerning the contents, correctness and sufficiency of the attachment and its contents for their purposes. 3. to the extent permitted by law, all conditions and warranties concerning this document or any use to which they may be put (whether as to quality, outcome, fitness, care, skill or otherwise) whether express or implied by statute, common law, equity, trade, custom or usage or otherwise are expressly excluded. 4. any person using or relying document releases and indemnifies and will keep indemnified Joe The Architect LLC against all claims, liabilities, loss, costs and expenses arising directly or indirectly out of or in connection with such use or reliance including without limitation any misrepresentation, error or defect in this document. JO E T H E A R C H I T E C T Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. All work to comply with I.B.C. Statutory Authorities and relevant American Standards. © 2023- all rights reserved 7/ 1 7 / 2 0 2 5 4 : 2 1 : 1 9 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 1 9 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t 95 B O S T O N R E S I D E N C E <S E T P H A S E > PR O J E C T N U M B E R : 9 3 5 DA T E : 0 7 / 1 7 / 2 5 95 BOSTON ST. SALEM, MA 01970 95 BOSTON RESIDENCE PROJECT NUMBER: 935 CLIENT CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 (805) 559-5778-T CONTACT: CHELSEA MCDONALD EMAIL: devinandchelseamcdonald@gmail.com ARCHITECT JOE THE ARCHITECT 343 MEDFORD STREET, SUITE 4C SOMERVILLE, MA 02145 (617) 764-3593-T CONTACT: CAMILLE SCHAPPLER EMAIL: CAMILLE@JOETHEARCHITECT.COM SHEET NUMBER SHEET NAME 01-GENERAL 0 0.00 COVER SHEET G 0.01 GENERAL NOTES, STANDARDS & ABBREVIATIONS 04-ARCHITECTURAL D 1.00 DEMOLITION PLAN - LEVEL 2 & 3 D 2.00 DEMOLITION REFLECTING CEILING PLAN - LEVEL 2 & 3 A 1.00 FLOOR PLAN - LEVEL 2 & 3 A 2.00 REFLECTED CEILING PLAN - LEVEL 2 & 3 A 3.00 EXTERIOR ELEVATIONS A 5.00 ENLARGED PLANS & INTERIOR ELEVATIONS A 5.01 ENLARGED PLANS & INTERIOR ELEVATIONS A 7.00 FINISH PLAN - LEVEL 2 & 3 A 7.30 SWITCHING PLAN - LEVEL 2 & 3 GENERAL NOTES AND LEGENDS 1. THE DRAWINGS HAVE BEEN COMPILED FROM THE BEST AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF WORK. THE CONTRACTOR MAY UNCOVER HIDDEN CONDITIONS NOT SHOWN IN THIS CONTRACT SET. 2. THE CONTRACTOR SHALL PERFORM ALL WORK DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS AND SHALL PROVIDE ALL ITEMS REQ'D FOR A COMPLETE FUNCTIONING SYSTEM, INCLUDING APPROPRIATE BLOCKING FOR WALL MOUNTED FIXTURES, SHELVING, ACCESSORIES, ETC. 3. WORK SHOWN BUT NOT INCLUDED IN THIS CONTRACT IS NOTED "N.I.C.". ITEMS TO BE PROVIDED BY OWNER AND INSTALLED BY G.C. ARE SO NOTED. 4. GENERAL CONTRACTOR SHALL MAKE ALL SUB-CONTRACTORS AND SUPPLIERS AWARE OF THE REQUIREMENTS OF THESE NOTES. 5. ALL WORK SHALL BE PERFORMED IN COMPLIANCE WITH ALL APPLICABLE LOCAL, STATE AND NATIONAL BUILDING, LIFE SAFETY, ELECTRICAL AND PLUMBING CODES HAVING JURISDICTION OVER THIS PROJECT. 6. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL PERMITS NECESSARY FOR THE COMPLETION OF THE WORK SHOWN THROUGHOUT THE CONTRACT DOCUMENTS. 7. GENERAL CONTRACTOR SHALL LAYOUT IN THE FIELD THE ENTIRE WORK TO BE PERFORMED TO VERIFY DIMENSIONAL RELATIONSHIPS BEFORE PROCEEDING WITH THE CONSTRUCTION AND SHALL VERIFY ALL EXISTING CONDITIONS AND LOCATIONS / BENCHMARKS BEFORE PROCEEDING WITH WORK / INSTALLATION. 8. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DIMENSIONAL REQUIREMENTS BETWEEN THE WORK OF THE REQUIRED TRADES AND SUB-CONTRACTORS. 9. DRAWINGS SHALL NOT BE SCALED FOR DIMENSIONS AND / OR SIZES. DRAWINGS MAY HAVE BEEN REPRODUCED AT A SCALE DIFFERENT THEN THAT ORIGINALLY DRAWN. 10. GENERAL CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS INCLUDING DIMENSIONS, STRUCTURE, UTILITY LINES, ETC. ANY DISCREPANCIES FOUND IN THE PLANS, DIMENSIONS, EXISTING CONDITIONS OR ANY APPARENT ERROR IN THE CLASSIFYING OF A PRODUCT, MATERIAL OR METHOD OF ASSEMBLY IS TO BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY. SK DRAWINGS WILL BE ISSUED WHEN OR AS REQUIRED. 11. G.C. & ALL TRADES, ARE RESPONSIBLE FOR COORDINATION OF THE LOCATIONS OF ALL MECH., ELEC., PLUMB. FIXTURES & DEVICES. IF CONFLICT EXIST BTW DRAWINGS, EXACT LOCATIONS SHALL BE PER ARCHITECTURAL DRAWINGS OR PER FIELD INSTRUCTION OF ARCHITECT. 12. G.C. & EA. TRADE SUBCONTRACTOR ARE RESPONSIBLE FOR REVIEWING & COORDINATING ALL TRADES' EQUIPMENT AND DISTRIBUTION INCLUDING PIPES, CONDUIT, ETC. TO ENSURE THAT ALL FIT IN THE ALLOCATED SPACE. ANY CONFLICT SHOULD BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND APPROPRIATE ENGINEER IMMEDIATELY, IN WRITING. 13. PROTECT ALL EXISTING WALLS, DOORS, ETC. TO REMAIN. THE CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF ALL FINISHES, FRAMING, AND UTILITIES DAMAGED OR DISTURBED DURING THE COURSE OF THE WORK, INCLUDING SHOP APPLIED FINISHES. EXISTING FINISHES DISTURBED DURING THE COURSE OF THE WORK SHALL BE REPAIRED SUCH THAT PATCHES WILL NOT BE DETECTABLE & THE NEW SURFACE WILL BE CONTINUOUS W/ ADJACENT SURFACES. WALL SURFACES SHALL BE SMOOTH, DURABLE, AND STABLE, FREE OF CRACKS, HOLES, DENTS ETC. 14. WHERE NEW WALLS OR CONSTRUCTION ARE TO MEET EXISTING, REPAIR OR REPLACE EXISTING ADJACENT FINISHES AS REQ. SUCH THAT THE JOINT IS SMOOTH, FLUSH AND INVISIBLE WHEN COMPLETED. 15. G.C. AND TRADES SHALL CUT PENETRATIONS FOR MEP/FP, SECURITY AND DATA SYSTEMS, THROUGH WALL, THROUGH CEILING, THROUGH FLOOR AND THROUGH ROOF AS REQUIRED. PATCHING OF ALL SURFACES W/ MATERIALS THAT MATCH AND ALIGN W/ THAT CUT SHALL BE ACCOMPLISHED UNDER THE BASE CONTRACT, WHETHER SPECIFICALLY SHOWN OR NOT. EACH TRADE IS RESPONSIBLE FOR PROVIDING APPROPRIATE FIRE RATED, FIRE RATED CAULK, ETC FOR ALL PENETRATIONS IN FIRE RATED SEPARATIONS IN ORDER TO MAINTAIN/RESTORE FIRE RATING. 16. DIMENSIONS: 1. -ALL PARTITION DIMENSIONS SHOWN ARE TO FACE OF STUD @ NEW WALL CONSTRUCTION U.O.N. 2. -DIMENSIONS NOTED AS "CLR." MEAN CLEAR DIM. TO FACE OF FINISH. 3. -ALL HORIZ. DIMS ARE SHOWN ON PLANS AND VERT. DIMS ON INTERIOR & EXTERIOR ELEVATIONS WHERE RELEVANT. 4. -VERTICAL DIMENSIONS ARE TO T.O. SUBFLOOR, U.O.N. 17. ALIGN ELECTRICAL DEVICES INCLUDING SWITCHES, OUTLETS, FIRE ALARM DEVICES, EMERGENCY LIGHTS, ETC. VERTICALLY & HORIZONTALLY, WHEREVER IN CLOSE PROXIMITY TO EACH OTHER, AND UNLESS PREVENTED BY CODE. SEE MOUNTING HEIGHTS SCHEDULE FOR TYP. HEIGHTS, SEE ELEVATIONS FOR SPECIFIC EXCEPTIONS. ALIGN CEILING DEVICES INCLUDING SMOKE DETECTORS, SPRINKLER HEADS, ETC., WITH CEILING MOUNTED LIGHTING FIXTURES UNLESS OTHERWISE NOTED. CENTER ALL BETWEEN ELEMENTS OR WITHIN GRID IN BOTH DIRECTIONS U.O.N. 18. EA. TRADE IS RESPONSIBLE FOR SEALING AIR TIGHT ANY PENETRATIONS MADE THROUGH AIR & VAPOR BARRIERS. 19. ALL METAL & MEMBRANE FLASHINGS TO BE LAPPED POSITIVELY TO DRAIN. 20. SEPARATE DISSIMILAR METALS. GENERAL NOTES AND LEGENDS ABBREVIATIONS the preceding list of abbreviations is presented as a general guide and does not necessarily show all abbreviations used. other generally accepted abbreviations may be found among the drawings. FPRF fireproof FRG fiber reinforced gypsum FRP fiber reinforced panel FRT fire retardant treatment FS full size FSP fire standpipe FTR fire treated FTG footing FURR furring F&I furnish and install FUT future G GA gauge GALV galvanized GB grab bar GC general contractor GFRC glass fiber reinforced concrete GFRG glass fiber reinforced gypsum GL glass / glazing GND ground GT grout GSF gross square foot GWB gypsum wall board GYP gypsum H H high HB hose bib HC hollow core HWD hardwood HDWE hardware HDWR hardware HM hollow metal HORIZ horizontal HPT highpoint HR hour HT height HGT height I ID inside diameter; inside dimension IN inch INFO information INSUL insulation INT interior J JAN janitor JT joint JST joist K KIT kitchen L LAB laboratory LAM laminate LAV lavatory LB pound LED light emitting diode LF linear feet LH left hand LKR locker LT light LVL laminated veneer lumber LVR louver LVT luxury vinyl tile M MAX maximum MC medicing cabinet MDF medium density fiberboard MDL modular MECH mechanical MEMB membrane MEP mechanical, electrical, plumbing MFR manufacturer MH manhole MIN minimum MIR mirror MISC miscellaneous MLD moulding MO masonry opening MTD mounted MTL metal MUL mullion MWK millwork N NC new construction NIC not in contract NO. or #number NOM nominal NSF net square footage NTS not to scale O OA overall OBS obscure OC on center OCC occupancy OD outside diamete (DIM.) OFF office OF/CI owner furnished/constractor installed OF/OI owner furnished/owner installed OFD overflow drain OHDR overhead door OH opposite hand OPNG opening OPP opposite ORIG original P P pendant PBF prefabricated PBL plumbing fixture PCC precast concrete PCF pounds per cubic foor PERF perforated PL plate PLAM plastic laminate PLA plaster PLF pounds per linear foot PLYWD plywood POS point of sale PR pair PRCST precast PRT partition PSF pounds per square foot PSI pounds per square inch PT paint PTD paper towel dispenser PTD/R combination paper towel dispenser and receptacle PTL pressure treated lumber PTR pressure treated PVMT pavement &and L angle @ at AL align CL centerline DIA.diameter PERP.perpendicular C channel #number or pound /per or divide A A/C air condition ACT acoustic ceiling tile AD area drain ADJ adjustable AFF above finished floor AGGR aggregate ALUM aluminum AP acoustic panel APPX approximate APT apartment ARCH architectural ASB asbestos ASPH asphault AVG average B BD board BITUM bimtuminous BLDG building BLK block BLKG blocking BM beam BO bottom of B/O by others BOD basis of design BOS bottom of steel BR bedroom BSMT basement BTB back to back C C celcius CAB cabinet CB catch basin CER ceramic CF/CI contractor furnished/ contractor installed CF/OI contractor furnished/ owner installed CG corner guard CH coat hook CI cast iron CIP cast in place CJ construction joint; control joint CL centerline CLG ceiling CLR clear CLO closet CM crown moulding CMU concrete masonry unit CNTR counter COL column CONC concrete CONT continuous CORR corridor CPT carpet CSW casework CTSK countersunk CT ceramic tile CTR center CUH cabinet unit heater CW curtain wall D D deep DBL double DEMO demolition DEPT department DET detail DF drinking fountain DH double hung DIA diameter DIM dimension DISP dispenser DN down DO door opening DR door DS downspout DSP dry stand pipe DW dishwasher DWG drawing(s) DWR drawer E E existing (E)east EA each EIFS exterior insulation and finish system EJ expansion joint EL elevation ELEC electrical ELVTR elevator EMER emergency ENCL enclosure EOS edge of slab EP electrical panel EPX epoxy EQ equal EQPT equipment ERD existing roof drain EWC electrical water cooler EXH exhaust EXIST existing EXP exposed EXT exterior F F fahrenheit FA fire alarm FACP fire alarm control panel FB flat bar FBO furnished by others FEC fire extinguisher cabinet FD floor drain FDC fire department connection FDN foundation FE fire extinguisher FEC fire extinguisher cabinet FHC fire hose cabinet FIN finish FLUOR flourescent FO finished opening FOC face of concrete FOM face of masonry FOS face of stud FOW face of wall FPL fireplace FPR fire protection riser Q QT quarry tile QTY quantity R R riser; right RA return air RAD radius RB resilient base RBR rubber base RCP reflected ceiling plan RD roof drain REF reference REFR refrigerator RELOC relocate REINF reinforced REQ'D required RESIL resilient REST restroom RGTR register RH right hand RM room RP resilient panel RO rough opening RSF resilient sheet flooring RTU rooftop unit RWD redwood RWL rain water leader S SA supply air SAB sound attenuation blankets SC solid core SCD seat cover dispenser SCHED schedule SD smoke detector SECT section SF square footage SH shelf SHR shower SHT sheet SIM similar SKL skylight SND sanitary napkin dispenser SNR sanitary napkin receptacle SNT sealant SOB symbol on background SO south SPD soap dispenser SPEC specification SQ square SS solid surface SSK service sink SST stainless steel ST stone STA station STD standard STL steel STOR storage STRL structural SUSP suspended SYM symmetrical T T tile TB towel bar TBD to be determined TC top of curb TEL telephone TEMP temporary TER terrazzo T&G tongue and groove THK thick TOC top of concrete TOP top of pavement TOS top of slab;top of steel TOW top of wall TPD toilet paper dispenser TR tread TV television TX textile upholstery TYP typical U UL underwriters' laboratories UNF unfinished UON unless otherwise noted UR urinal V VAR varnish VB vapor barrier VCT vinyl composition tile VERT vertical VEST vestibule VIF verify in field VNR veneer W W west W/ with WB wall base WC wall covering WD wood W/O without WP waterproof WSCT wainscot WT weight WTC water closet WWM welded wire mesh GENERAL NOTES AND LEGENDS SYMBOL LEGEND see discipline sheets for discipline specific symbols NORTH ARROW sheet # sequence sheet # SHEET NUMBER sheet series discipline true north project northA100 N GRID BUBBLES Plan or Detail Callout View Scale PLAN OR DETAIL TITLE Plan or Detail Callout 1 View Name 1/8" = 1'-0" 0 0 EXTERNAL ELEVATION REFERENCE INTERNAL ELEVATION REFERENCE Exterior elevation callout Sheet on which elevation is drawn A101 1 Ref 1 Re f 1 Ref 1 Re f A101 1 Ref 1 Re f 1 Ref 1 Re f Exterior elevation callout Sheet on which elevation is drawn BUILDING SECTION REFERENCE WALL SECTION REFERENCE DETAIL SECTION REFERENCE DETAIL CALLOUT REFERENCE A101 SIM A 1 A101 SIM Building section number Sheet on which section is drawn Building section number Sheet on which section is drawn STAIR TAG SPOT ELEVATION LEVEL HEADS MATCHLINE REFERENCE CENTERLINE TAG WALL TAG CEILING TAG REVISION CALLOUT AND CLOUD FLOW ARROW REFERENCE DETAIL SECTION REFERENCE DETAIL CALLOUT REFERENCE ROOM NAME W/ ROOM NUMBER W/AREA WINDOW TAGDOOR TAGS FURNITURE TAG FINISH TAGCASEWORK TAG OFFICE OFFICE G.01 OFFICE G.01 150 SF 1.2 W1 R @ 7 1/2"20 CE1 +9'-0" A.F.L S1-2000 WT-1 Name Elevation TypeMark 2 /MATCHLINE SEE: 1 A101 Callout section number Sheet on which callout is drawn A101 1 SIM EGRESS DOOR TAG 1.2 Mark frame type 101 1 P6 3 1t 36 48 mark panel type hardware set A1 WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 0 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 0 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:20 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 GENERAL NOTES, STANDARDS & ABBREVIATIONS G 0.01 <S E T P H A S E > 935 CW AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 UP UP EXISITING SOLID PARTITION TO BE DEMOLISHED EXISTING DOOR AND FRAME TO BE DEMOLISHED EXISITING FULL HEIGHT SOLID, GLAZER OR PART GLAZED PARTITION TO REMAIN EXISTING DOOR AND FRAME TO REMAIN DEMOLITION LEGEND NIC - NOT IN CONTRACT HATCH EXISITING GLAZED OR PARTIALLY GLAZED PARTITION TO BE DEMOLISHED GENERAL NOTES - DEMOLITION 1. SEE GENERAL CONSTRUCTION NOTES ON SHEET G 0.01. 2. THE DRAWINGS HAVE BEEN COMPILED FROM THE BEST AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF WORK. THE CONTRACTOR MAY UNCOVER HIDDEN CONDITIONS NOT SHOWN IN THIS CONTRACT SET. IN SUCH AN EVENT, THE CONTRACTOR SHALL CONTACT THE ARCHITECT IMMEDIATELY. 3. SELECTIVELY DEMO WALLS, CEILING, AND FLOOR FINISHES AS SHOWN AND AS REQUIRED FOR NEW LAYOUT AND SYSTEMS. 4. GC TO COORDINATE CUTTING OF NEW DOOR OPENINGS WITH REQUIRED DIMS FOR UNITS AS SHOWN ON FLOOR PLANS, ELEVATIONS, AND DOOR SCHEDULE. NOTIFY ARCHITECT OF ANY CONFLICTS. 5. THE CONTRACTOR SHALL PERFORM DEMO AS REQUIRED FOR WALL MOUNTED FIXTURES, SHELVING, ACCESSORIES, ETC, WHETHER SPECIFICALLY SHOWN OR NOT. 6. WHERE REMOVAL OF EXSITING CONSTRUCTION IS REQUIRED FOR PERFORMANCE OF ANY WORK UNDER THIS CONTRACT, REMOVAL & REINSTALLATION SHALL BE ACCOMPLISHED UNDER THE BASE CONTRACT, WHETHER SPECIFICALLY SHOWN OR NOT, INCLUDING RESTORATION OF UTILITIES AND ANY TEMPORARY SHORING OF STRUCTURAL COMPONENTS. 7. PROTECT ALL EXISTING WALLS, DOORS, ETC. TO REMAIN. THE CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF ALL FINISHES, FRAMING, AND UTILITIES DAMAGED OR DISTURBED DURING THE COURSE OF THE WORK, INCLUDING SHOP APPLIED FINISHES. 8. IT IS THE INTENT OF THE DEMOLITION SCOPE TO REMOVE ALL EXISTING ITEMS THAT WILL CONFLICT WITH NEW WORK WHETHER SHOWN OR NOT. ALL EXISTING NON-STRUCTURAL PARTITIONS, CEILINGS, CASEWORK, MEP/FP ITEMS, FURR-OUTS, FINISH MATERIALS, STAIRS, DOORS, WINDOWS AND INDUSTRIAL EQUIPMENT SHALL BE REMOVED. THE CONTRACTOR SHALL VISIT THE SITE PRIOR OF THE START OF ANY WORK TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS. 9. ROOFING SUBCONTRACTOR IS RESPONSIBLE FOR REMOVAL OF ALL ROOFING, INCLUDING NON-STRUCTURAL SUBSTRATES, GUTTERS, AND ASSOCIATED FLASHINGS. REMOVED MATERIAL SHALL BE DISPOSED OF BY THE GENERAL CONTRACTOR. 10. COORDINATE ALL DEMOLITION WITH HAZARDOUS MATERIAL REMOVAL/ABATEMENT REQUIREMENTS. 11. GENERAL CONTRACTOR IS RESPONSIBLE FOR DISPOSAL OF ALL EXCESS SALVAGED ITEMS NOT USED IN THE PROJECT OR REQUESTED TO BE RETURNED TO THE OWNER. 12. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND REVIEW WITH ALL TRADES THE EXTENT OF DEMOLITION REQUIRED. 13. THE CONTRACTOR SHALL PROTECT ALL MATERIALS AND EQUIPMENT NOTED TO REMAIN. ALL MATERIAL INDICATED TO BE SALVAGED OR REINSTALLED SHALL BE STORED AND PROTECTED FROM DAMAGE UNTIL READY TO BE PERMANENTLY REINSTALLED. 14. ALL MATERIAL INDICATED TO BE REMOVED SHALL BE DISPOSED OF IN ACCORDANCE TO APPLICABLE CODES AND LAWS. THE OWNER RETAINS THE RIGHT TO RECLAIM ANY EXISTING MATERIAL. SUCH MATERIAL SHALL BE PROTECTED FROM DAMAGE AND DELIVERED TO THE OWNER AS PER OWNER’S REQUIREMENTS AND COMPLIANCE WITH SUSTAINABLE PRACTICES. AT THE END OF DEMOLITION, LEAVE THE AREA FREE AND CLEAR. BROOM CLEAN FOR THE APPLICATION OF NEW WORK. 15. THE CONTRACTOR SHALL PROVIDE PROTECTION AROUND AND OVER ALL FLOOR OPENINGS. COORDINATE ALL NEW FLOOR OPENING DIMENSIONS WITH ARCHITECTURAL DRAWINGS. 16. WHERE FLOOR FINISH REMOVAL IS INDICATED, REMOVE FLOORING MATERIALS DOWN TO SUBSTRATE. 17. CLEAN ANY RESIDUE FROM CONCRETE SURFACE. PREP SUBSTRATE TO RECEIVE FINISH AS INDICATED ON FINISH SCHEDULE AND PER FLOORING MANUFACTURES RECOMMENDATIONS. 18. WHERE CEILING REMOVAL IS INDICATED, REMOVE ALL COMPONENTS OF EXISTING CEILING SYSTEMS INCLUDING ALL FASTENERS. ALL MATERIALS AND EQUIPMENT SHALL BE REMOVED TO UNDERSIDE OF STRUCTURE ABOVE. PREP SURFACE OF UNDERSIDE OF STRUCTURE FOR NEW FINISH PER FINISH SCHEDULE. 19. CONTRACTOR TO PROVIDE TEMPORARY PROTECTION FOR INTERIOR SIDE OF ALL EXTERIOR WALLS AND SURFACES WHICH WILL REMAIN AFTER DEMOLITION. 20. PROVIDE TEMPORARY ENCLOSURE OF ALL EXTERIOR OPENINGS CREATED AS A RESULT OF DEMOLITION UNTIL PERMANENT ENCLOSURES ARE INSTALLED 21. PROVIDE TEMPORARY SHORING AT ALL DEMOLITION OF NEW OPENINGS TO INSTALL NEW LINTEL AS INDICATED. 22. ALL 'MEP/FP' WORK IS TO BE PROVIDED BY THE GENERAL CONTRACTOR ON A DESIGN/BUILD BASIS. D2 D4 D5 D3 D1 D1 D1 D1 D12 D6 D7 D8 D9 D6 WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 0 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 0 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:20 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 DEMOLITION PLAN - LEVEL 2 & 3 D 1.00 <S E T P H A S E > 935 CS AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 KEY NOTES_DEMOLITION D1 EXISTING FLOOR TO REMAIN UNLESS OTHERWISE NOTED, PROTECT DURING CONSTRUCTION D2 CLIENT TO REMOVE FURNITURE PEICE BEFORE NEW CABINET INSTALLATION D3 DEMO EXISTING COUNTERTOP BACKSPLASH & PREP GWB WALL FOR NEW BACKSPLASH TILE INSTALLATION D4 DEMO EXISTING FOE BEADBOARD AND EXISTING TRIM, PREP WALLS FOR NEW PAINT D5 EXSITING WOOD FLOOR TO BE DEMOLISHED, EXISTING WOOD FLOORS TO BE SALVAGED TO BE USED AT STAIR OPENING. GC TO TAKE CARE DURING DEMO TO SAVE AS MUCH AS POSSIBLE FOR REUSE. D6 EXTERIOR WALL TO BE DEMOLISHED TO PREP FOR NEW DORMER D7 DEMO EXISTING FLOOR PREP FOR NEW TILE APPLICATION D8 DEMO ALL EXISTING BATHROOM ELEMENTS INCLUDING THE BEADBOARD WAINSCOTTING ON THE REMAINING WALLS D9 DEMO EXISTING WINDOW D10 DEMO EXISTING SLOPED CEILING MAINTAINING WHATS NEEDED TO MEET NEW DORMER CEILING. SEE SHEET A3.00 FOR MORE INFORMATION ON NEW DORMER D11 DEMO EXISTING PENDANT LIGHTS, D12 EXISTING DOOR TO BE RUSED, TAKE CARE DURING DEMO TO ENSURE REUSE IN NEW LOCATION. D13 EXISTING LIGHT FIXTURE TO BE SALVAGED AND RELOCATED. 1/4" = 1'-0"D 1.00 1 DEMOLITION PLAN - LEVEL 2 1/4" = 1'-0"D 1.00 2 DEMOLITION PLAN - LEVEL 3 N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 S ASD S ASD S ASD DEMOLITION LEGEND - REFLECTED CEILING PLAN EXISTING LIGHT FIXTURE TO BE DEMOLISHED EXISTING LIGHT FIXTURE TO REMAIN NIC -NOT IN CONTRACT EXISTING CEILING TO BE DEMOLISHED EXISTING CEILING TO REMAIN GENERAL NOTES DEMOLITION REFLECTED CEILING PLAN 1. SEE GENERAL CONSTRUCTION NOTES ON SHEET G 0.01. 2. THE DRAWINGS HAVE BEEN COMPILED FROM THE BEST AVAILABLE INFORMATION AND ARE NOT INTENDED TO LIMIT THE SCOPE OF WORK. THE CONTRACTOR MAY UNCOVER HIDDEN CONDITIONS NOT SHOWN IN THIS CONTRACT SET. IN SUCH AN EVENT, THE CONTRACTOR SHALL CONTACT THE ARCHITECT IMMEDIATELY. 3. SELECTIVELY DEMO CEILING AS SHOWN AND AS REQUIRED FOR NEW LAYOUT AND SYSTEMS. 4. THE CONTRACTOR SHALL PERFORM DEMO AS REQUIRED FOR CEILING MOUNTED FIXTURES, ACCESSORIES, ETC, WHETHER SPECIFICALLY SHOWN OR NOT. 5. WHERE REMOVAL OF EXSITING CONSTRUCTION IS REQUIRED FOR PERFORMANCE OF ANY WORK UNDER THIS CONTRACT, REMOVAL & REINSTALLATION SHALL BE ACCOMPLISHED UNDER THE BASE CONTRACT, WHETHER SPECIFICALLY SHOWN OR NOT, INCLUDING RESTORATION OF UTILITIES AND ANY TEMPORARY SHORING OF STRUCTURAL COMPONENTS. 6. PROTECT ALL EXISTING WALLS, DOORS, ETC. TO REMAIN. THE CONTRACTOR IS RESPONSIBLE FOR THE REPAIR OR REPLACEMENT OF ALL FINISHES, FRAMING, AND UTILITIES DAMAGED OR DISTURBED DURING THE COURSE OF THE WORK, INCLUDING SHOP APPLIED FINISHES. 7. SEE ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION DRAWINGS AND SPECIFICATIONS FOR RELEVANT INFO AND COORDINATION FOR SYSTEMS WORK. CUT PENETRATIONS FOR MEP/FP, SECURITY AND DATA SYSTEMS, THROUGH WALL, THROUGH CEILING, THROUGH FLOOR AND THROUGH ROOF AS REQUIRED. 8. ALL NEW SPRINKLERS & PIPING SHALL BE INSTALLED PRIOR TO DEMOLISHING THE (E) SYSTEM & MAKING FINAL CONNECTIONS, IN ORDER TO MINIMIZE THE IMPACTS OF SHUTDOWNS, DRAIN DOWN, SYSTEM RE- FILL, AND FIRE WATCHES. 9. GENERAL CONTRACTOR IS RESPONSIBLE FOR DISPOSAL OF ALL EXCESS SALVAGED ITEMS NOT USED IN THE PROJECT OR REQUESTED TO BE RETURNED TO THE OWNER. 10. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND REVIEW WITH ALL TRADES THE EXTENT OF DEMOLITION REQUIRED. 11. THE CONTRACTOR SHALL PROTECT ALL MATERIALS AND EQUIPMENT NOTED TO REMAIN. ALL MATERIAL INDICATED TO BE SALVAGED OR REINSTALLED SHALL BE STORED AND PROTECTED FROM DAMAGE UNTIL READY TO BE PERMANENTLY REINSTALLED. 12. ALL MATERIAL INDICATED TO BE REMOVED SHALL BE DISPOSED OF IN ACCORDANCE TO APPLICABLE CODES AND LAWS. THE OWNER RETAINS THE RIGHT TO RECLAIM ANY EXISTING MATERIAL. SUCH MATERIAL SHALL BE PROTECTED FROM DAMAGE AND DELIVERED TO THE OWNER AS PER OWNER’S REQUIREMENTS AND COMPLIANCE WITH SUSTAINABLE PRACTICES. 13. SEE MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL DRAWINGS FOR SCOPE OF MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL DEMOLITION. CUT, CAP, AND MAKE SAFE ALL PIPING, CONDUIT, AND WIRING AS INDICATED ON RELATED DRAWINGS. 14. LOCATIONS OF (E) SPRINKLER HEADS, LIGHTING, HVAC DIFFUSERS/REGISTERS, ETC, AND A.C.T. GRIDS ARE NOT FIELD DIMENSIONED. G.C. TO VERIFY LOCATIONS WHERE IN PROXIMITY OF WORK. 15. SPRINKLER HEADS, LIGHTING, HVAC DIFFUSERS/REGISTERS, ETC, AND A.C.T. GRIDS ARE EXISTING TO REMAIN U.O.N. 16. ALL 'MEP/FP' WORK IS TO BE PROVIDED BY THE GENERAL CONTRACTOR ON A DESIGN/BUILD BASIS. D13 D10 D11 WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 0 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 0 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:20 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 DEMOLITION REFLECTING CEILING PLAN - LEVEL 2 & 3 D 2.00 <S E T P H A S E > 935 CS AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 KEY NOTES_DEMOLITION D1 EXISTING FLOOR TO REMAIN UNLESS OTHERWISE NOTED, PROTECT DURING CONSTRUCTION D2 CLIENT TO REMOVE FURNITURE PEICE BEFORE NEW CABINET INSTALLATION D3 DEMO EXISTING COUNTERTOP BACKSPLASH & PREP GWB WALL FOR NEW BACKSPLASH TILE INSTALLATION D4 DEMO EXISTING FOE BEADBOARD AND EXISTING TRIM, PREP WALLS FOR NEW PAINT D5 EXSITING WOOD FLOOR TO BE DEMOLISHED, EXISTING WOOD FLOORS TO BE SALVAGED TO BE USED AT STAIR OPENING. GC TO TAKE CARE DURING DEMO TO SAVE AS MUCH AS POSSIBLE FOR REUSE. D6 EXTERIOR WALL TO BE DEMOLISHED TO PREP FOR NEW DORMER D7 DEMO EXISTING FLOOR PREP FOR NEW TILE APPLICATION D8 DEMO ALL EXISTING BATHROOM ELEMENTS INCLUDING THE BEADBOARD WAINSCOTTING ON THE REMAINING WALLS D9 DEMO EXISTING WINDOW D10 DEMO EXISTING SLOPED CEILING MAINTAINING WHATS NEEDED TO MEET NEW DORMER CEILING. SEE SHEET A3.00 FOR MORE INFORMATION ON NEW DORMER D11 DEMO EXISTING PENDANT LIGHTS, D12 EXISTING DOOR TO BE RUSED, TAKE CARE DURING DEMO TO ENSURE REUSE IN NEW LOCATION. D13 EXISTING LIGHT FIXTURE TO BE SALVAGED AND RELOCATED. 1/4" = 1'-0"D 2.00 1 DEMOLITION REFLECTED CEILING PLAN - LEVEL 2 1/4" = 1'-0"D 2.00 2 DEMOLITION REFLECTED CEILING PLAN - LEVEL 3 N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 DW UP UP UP GENERAL NOTES - CONSTRUCTION 1. SEE INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION ON WALL FINISH MATERIALS AND TYPICAL MOUNTING HEIGHTS REQUIRED. 2. SEE GENERAL CONSTRUCTION NOTES ON SHEET G001. 3. SEE REFLECTED CEILING PLANS FOR CEILING FINISH MATERIALS. 4. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AFTER DEMOLITION IS COMPLETED. 5. ALL LOCATIONS WHERE INFILL WALLS MEET EXISTING WALLS WITH NEW GWB FINISH SURFACES SHALL ALIGN AT ADJACENT EDGES UNLESS OTHERWISE NOTED. 6. EXISTING WALLS SHOWN WITH ADDITIONAL LINES GRAPHICALLY REPRESENT NEW FINISHES AND SHOULD NOT BE SCALED OR DIMENSIONED FROM. PARTITIONS SHOULD BE BUILT AND FINISHED ACCORDING TO PARTITION AND FINISH SCHEDULE. 7. COORDINATE AREAWAY DRAINS AND FLOOR DRAINS WITH PLUMBING DRAWINGS. 8. PROVIDE BLOCKING FOR GRAB BARS, PLUMBING FIXTURES, MILL WORK AT ALL REQUIRE LOCATIONS. 9. ALL DIMENSIONS INDICATED WITH A ± REPRESENT FIELD MEASUREMENTS TO BE PROVIDED TO ARCHITECT AND VERIFIED BY CONTRACTOR. 10. ALL NEW DOORS & TRIM TO MATCH EXISTING. 11. ALL GLASS WITHIN 18”A.F.F. AND/OR WITHIN 4’-0”OF A DOOR SWING SHALL BE TEMPERED SAFETY GLASS. 12. ALL EXISTING WALLS TO BE PATCHED WHERE EXISTING WALLS WERE REMOVED. 13. PROVIDE LEVELING COMPOUND OVER ALL EXISTING CONCRETE FLOOR AREAS TO RECEIVE NEW FLOOR COVERING. NO FLOORING TRANSITIONS ARE TO EXCEED 1/2" IN HEIGHT. 14. PROVIDE IN-WALL BLOCKING AS REQUIRED. 15. PROVIDE IN-WALL BLOCKING FOR ALL FUTURE BUILT-IN CASEWORK WHERE INDICATED. 16. PATCH EXISTING GWB AT ALL LOCATIONS WHERE A PARTITION HAS BEEN REMOVED. 17. SEAL AIR TIGHT ANY PENETRATIONS MADE THROUGH AIR & VAPOR BARRIERS. 18. PAINT ALL (N) AND (E) GWB & PLASTER FINISHES IN WORK AREA UNLESS NOTED 19. INTERIOR DIMENSIONS ARE INDICATED TO FINISH WALL (CMU OR GYPSUM BOARD) MATERIALS. U.N.O. 20. EXTERIOR MASONRY DIMENSIONS ARE INDICATED TO CENTERLINE OF JOINTS. 21. WINDOW DIMENSIONS ARE TO CENTER LINE OF OPENING; DIMENSIONS ARE NOMINAL. SEE CURTAIN WALL, DOOR & WINDOW SCHEDULE AND DETAILS FOR ACTUAL OPENING DIMENSION REQUIRED. 22. PROVIDE LEVELING COMPOUND AS REQ. FOR PROPER TILE INSTALLATION TO ACHIEVE SMOOTH, LEVEL, FLUSH FINISH. 23. ALL MATERIAL INSTALLATION TO BE LEVEL & PLUMB. 24. SEE A7.00 SERIES FOR ALL FINISHES. 25. ALL 'MEP/FP' WORK IS TO BE PROVIDED BY THE GENERAL CONTRACTOR ON A DESIGN/BUILD BASIS. CONSTRUCTION LEGEND EXISTING DOOR TO REMAIN NIC -NOT IN CONTRACT HATCH NEW GWB PARTITION EXISTING GWB PARTITION TO REMAIN EXISTING GLAZED PARTITION TO REMAIN NEW DOOR AND FRAME NEW GLAZED PARTITION SYMBOL DEFINITION A 5.00 6 A 5.00 1 A 5.00 4 KITCHEN DINING ROOM LIVING ROOM BEDROOM 2 BATHROOM LAUNDRY ROOM BEDROOM 1 P1 A 3.002 6'-2" 2' - 0 " 6" 3' - 1 " 1'-10"+/ - 3' - 0 " P5 A 5.01 1 P2 A 3.00 1 P3P4 P6 WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 1 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 1 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:21 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 FLOOR PLAN - LEVEL 2 & 3 A 1.00 <S E T P H A S E > 935 CS AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 KEY NOTES_PROPOSED PLAN P1 NEW DOOR LOCTION, DOOR TO BE REUSED OR NEW TO MATCH EXISTING DOOR PANEL. TRIM TO MATCH EXISTING P2 NEW HALF HEIGHT WALL WITH QUARTZ WALL CAP P3 DEEP ADJUSTABLE SHELVES TO BE INSTALLED WITHIN CLOSET P4 NEW DOOR TO MATCH EXISTING ADJACENT P5 NEW 18" X 24" TRANSUM WINDOWS TO BE INSTALLED IN NEW WALL. GC TO COORDIANTE WITH CLIENT ON WINDOW SPEC. SEE ELEVATIONS FOR MORE INFORMATION ON MOUNTING HEIGHTS P6 NEW FINISHED LEDGE, GC TO COORDINATE WITH CLIENT ON FINAL FINISH. 1/4" = 1'-0"A 1.00 1 FLOOR PLAN - LEVEL 2 1/4" = 1'-0"A 1.00 2 FLOOR PLAN - LEVEL 3 N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 S S ASD S ASD S ASD REFLECTED CEILING PLAN LEGEND EXISTING CEILING TO REMAIN NEW CEILING (REFER TO TYPE SCHEDULE) EXISTING LIGHTING NEW LIGHTING (REFER TO LIGHTING SCHEDULED) LED-1 R-1L-1 FIXTURE TYPE TAG NIC -NOT IN CONTRACT HATCH SYMBOL DEFINITION EX EX EX REFLECTED CEILING NOTES 1. REFER TO GENERAL CONDITIONS, SPECIFICATIONS AND SCHEDULED FOR ALL WORK. 2. CONFIRM WITH ARCHITECT THAT THESE DRAWINGS ARE THE MOST CURRENT ISSUE BEFORE BEGINNING LAYOUT AND CONSTRUCTION. 3. ELECTRICAL SUBCONTRACTOR TO COORDINATE LIGHT FIXTURE TYPES, LOCATIONS AND INSTALLMENT WITH REFLECTED CEILING PLAN. THE SUBCONTRACTOR IS TO NOTIFY THE GENERAL CONTRACTOR AND THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO BID SUBMISSION AND INSTALLATION. 4. PROVIDE ANY ADDITIONAL CEILING BRACING AS REQUIRED BY LOCAL BUILDING CODES. 5. ALL FIXTURES NOT LOCATED BY DIMENSIONS OR SHOWN CLEARLY BY THIS DRAWING SET MUST HAVE THEIR LOCATION APPROVED BY THE ARCHITECT. 6. ALIGN ALL ENDS OF FIXTURE "RUNS" WITH EACH OTHER WHEN SHOWN PARALLEL IN RCPS, UNLESS OTHERWISE NOTED. 7. ALL DIMENSIONS ARE CENTER LINE OF FIXTURE AND FACE OF WLL UNLESS OTHERWISE NOTED. 8. ALL 'MEP/FP' WORK IS TO BE PROVIDED BY THE GENERAL CONTRACTOR ON A DESIGN/BUILD BASIS. LIVING ROOM BEDROOM 1 BEDROOM 2 BATHROOM DINING ROOM KITCHEN LAUNDRY ROOM 3' - 0 " 4'-1"2'-6" RC1 10" EX EX EX EX EX R1 EX EX EX R1 R1 R1 F1 1' - 3 " LED1 LED1 RC4 R1 R1 R1 R1 2'-4"4'-1" 3'-5" 1' - 2 " LED1 RC2 CF1 S1 S1 RC3 BATHROOM PRIMARY BEDROOM RC1 RC1 WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 2 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 2 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:22 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 REFLECTED CEILING PLAN - LEVEL 2 & 3 A 2.00 <S E T P H A S E > 935 CS AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 KEY NOTES_RCP RC1 NEW GYP CEILING TO MATCH EXISTING GYP CEILING HEIGHT, PAINT TO MATCH RC2 FOE BEAM TO BE INSTALLED ON TOP OF EXISTING BEAM TO PROVIDE MOUNTING SPACE FOR CEILING FAN, FOE BEAM TO BE WOOD FINISH TO MATCH OTHER EXISTING WOOD STRUCTURE RC3 EXISTING SLOPE CEILING TO BE PAINTED PT-4. EXPOSED WOOD STRUCTURE FINISH TO REMAIN RC4 NEW LIGHT FIXTURE LOCATION FOR SALVAGED FIXTURE IN EXSITING POWDER ROOM 1/4" = 1'-0"A 2.00 1 REFLECTED CEILING PLAN - LEVEL 2 1/4" = 1'-0"A 2.00 2 REFLECTED CEILING PLAN - LEVEL 3 LIGHTING SCHEDULE_ Type Mark Description Manufacturer Model Finish LF_Dimensions Remarks CF1 CEILING FAN WITH LIGHT TBD TBD TBD 48" D MAX GC TO CHECK IN WITH CLIENT ON CEILING FAN SELECTION F1 EXHAUST FAN LIGHT Delta Products Corporation ITG50LED WHITE GC TO CHECK IN WITH CLIENT BEFORE PURCHASE, LOCATION MAY DIFFER DEPENDING ON APPROVED SPEC LED1 LED STRIP LIGHT (WATERPROOF) ASPECT LED AL-SL-LR-U-WW-12 7/16" W GC TO INSTALL USING IN WALL RECESSED CHANNEL FROSTED LENSE. SEE DETAILS ON A5.00 & A5.01 FOR MORE DETAIL ON PLACEMENT. LIGHTS TO BE INSTALLED ON DIMMER R1 ROUND SURFACE MOUN DOWNLIGHT COOPER LIGHTING SOLUTIONS SMD4R -6-932700K-WT WHITE 4" D LIGHTS TO BE INSTALLED ON DIMMER S1 DECORATIVE WALL SCONCE MITZI LOLA WALL SCONCE AGED BRASS LIGHTS TO BE INSTALLED ON DIMMER DELTA BREEZ N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 Floor 01 0' -0" Floor 02 7' -11 1/2" Floor 03 16' -2" Roof 23' -6" SIDING TO MATCH EXISTING WINDOWS TO BE TEMPERED LOW SLOPE EPDM ROOF 363 363 363363 Floor 01 0' -0" Floor 02 7' -11 1/2" Floor 03 16' -2" Roof 23' -6" SIDING TO MATCH EXISTING LOW SLOPE EPDM ROOF Floor 03 16' -2" Roof 23' -6" CEILING JOISTS NEW BEAM TBD WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 3 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 3 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:23 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 EXTERIOR ELEVATIONS A 3.00 <S E T P H A S E > 935 JD CS CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 1/4" = 1'-0"A 3.00 1 RIGHT ELEVATION 1/4" = 1'-0"A 3.00 2 REAR ELEVATION JtA_WINDOWS Type Mark Note Family Type Count Height Width 26 WN_Casement-Transom 24" x 18" 3 18" 24" 363 TEMPERED GLASS WN_Double Hung Single w Mullions_FV 28x44 3 38" 23" 1/2" = 1'-0"A 3.00 3 BATHROOM DORMER SECTION N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 A 5.00 2 3 2'-10"5'-2" 1'-6" A B C DE F G HI J K BATHROOM 6' - 7 " A 5.00 5 1' - 0 " 2'-7" LAUNDRY ROOM 2' - 9 " OPEN 2' - 3 " D E G PORCELAIN WALL TILE FULL HEIGHT, PWT-1 SHOWER NICHE TILED W/ PWT-1 WOOD LOOK PORCELAIN TILE SILL, WPT-1 CASED OUT NICHE PAINTED TO MATCH WALL GYP WALL PAINTED, PT-3 9 A 5.00 Sim 8 A 5.00 Sim TRANSOM WINDOWS 5' - 7 " 4' - 0 " J WALL TO BE PAINTED, PT-3 PORCELAIN WALL TILE, PWT-1 C RECESSED LED STRIP LIGHT WITHIN NICHE,TYP. W D OPEN O P E N O P E N 3' - 3 " HINGED CASEWORK PANEL PAINTED TO MATCH ADJACENT WALL1' - 0 " SOLID WOOD COUNTERTOP, BB-1 HINGED ON WINDOW SIDE TO FLIP UP. HINGED ON RIGHT OFF OF WINDOW SILL WHITE CUBBY WITH OPEN ADUSTABLE SHELF, MOVABLE GYP WALL PAINTED, PT-2 E2 E3 2' - 8 " 3' - 0 " E1 EX EX 2' - 6 " 1' - 6 " GYP WALL PAINTED, PT-1 BACKSPLASH TILE, PWT-3 COUNTERTOP TO MATCH EXISTING BASE CORNER CABINET STYLE AND COLOR TO MATCH EXISTING 12" BASE CABINET WITH HIDDEN PULL OUT DRAWERS, SYLE AND COLOR TO MATCH EXISTING ULTRA SLIM UPPER CABINET STYLE TO MATCH EXISTING 1' - 0 " WOOD LOOK PORCELAIN TILE STILL MITERED EDGE, TYP. RECESSED LED STRIP LIGHT, LED-1 WALL TO BE TILED, PWT-1 1/ 2 " WALL TO BE TILED, PWT-1 4" 1' - 0 " GYPSUM WALL PAINTED, PT-3 WOOD LOOK PORCELAIN TILE STILL MITERED EDGE, TYP. RECESSED LED STRIP LIGHT, LED-1 GYPSUM WALL PAINTED, PT-3 ALL EXPOSED FACES 1/ 2 " WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 4 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 4 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:24 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 ENLARGED PLANS & INTERIOR ELEVATIONS A 5.00 <S E T P H A S E > 935 CS AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 1/2" = 1'-0"A 5.00 1 ENLARGED PLAN - LEVEL 2 BATHROOM 1/2" = 1'-0"A 5.00 4 ENLARGED PLAN - LAUNDRY ROOM 1/2" = 1'-0"A 5.00 2 2ND FLOOR BATHROOM NORTH 1/2" = 1'-0"A 5.00 3 2ND FLOOR BATHROOM EAST 1/2" = 1'-0"A 5.00 5 LAUNDRY ROOM 1/2" = 1'-0"A 5.00 6 KITCHEN NORTH RESTROOM PLUMBING FIXTURE & ACCESSORIES SCHEDULE TAG DESCRIPTION MANUFACTURE MODEL # COMMENTS PROVIDED BY A UNDERMOUNT SINK TBD TBD COORDINATE WITH VANITY TOP BY CLIENT B FAUCET TBD TBD COORDINATE WITH VANITY TOP BY CLIENT C 48" VANITY TBD TBD SOLID WOOD WITH STONE TOP BY CLIENT D GLASS SHOWER ENCLOSURE TBD TBD BY CLIENT E 60" TUB TBD TBD BY CLIENT F SHOWER HEAD & SHOWER THERMOSTATIC TBD TBD BY CLIENT G TOILET TBD TBD BY CLIENT H TP HOLDER TBD TBD BY CLIENT I 30" - 36" TOWEL BAR TBD TBD BY CLIENT J 30"D BACKLIT MIRROR TBD TBD BY CLIENT K HAND TOWEL HOLDER TBD TBD BY CLIENT L 60" VANITY TBD TBD SOLID WOOD WITH STONE TOP BY CLIENT M UNDERMOUNT SINK TBD TBD COORDINATE WITH VANITY TOP BY CLIENT N FAUCET TBD TBD COORDINATE WITH VANITY TOP BY CLIENT O 30" X 48" MIRROR TBD TBD BY CLIENT P GLASS SHOWER ENCLOSURE TBD TBD BY CLIENT Q SHOWER HEAD & SHOWER THERMOSTATIC TBD TBD BY CLIENT R RAIN SHOWER HEAD/ SECOND SHOWER HEAD TBD TBD STYLE TO MATCH Q BY CLIENT S TP HOLDER TBD TBD BY CLIENT T 30" - 36" TOWEL BAR TBD TBD BY CLIENT U HAND TOWEL HOLDER TBD TBD BY CLIENT EQUIPMENT SCHEDULE TAG DESCRIPTION MANUFACTURE MODEL DIMENSIONS PROVIDED BY E1 UNDER COUNTER BEVERAGE REFRIGERATOR TBD TBD 24" WIDE BY CLIENT E2 STACKABLE WASHER TBD TBD 24" WIDE BY CLIENT E3 STACHABLE DRYER TBD TBD 24" WIDE BY CLIENT 1 1/2" = 1'-0"A 5.00 8 DETAIL - BATHROOM SHOWER NICHE 1 1/2" = 1'-0"A 5.00 9 DETAIL - BATHROOM NICHE STACKED N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 A 5.014 2 3 L M M N N O P Q U S T T 8' - 7 " 3' - 1 " 2' - 6 " 5" 2' - 1 0 " BATHROOM G V.I.F - EXISTING WIDTH OF STAIR 5'-1" 3' - 7 1 / 2 " 15'-5" 2'-10" ALIGN 1' - 6 " 4'-7" PORCELAIN WALL TILE, PWT-1 Q O L GYP WALL PAINTED, PT-5 CE N T E R L I N E O F M I R R O R 5' - 3 " 3"4'-7" R P PORCELAI WALL TILE, PWT-1 GYP WALL TO BE PAINTED, PT-5 NEW WINDOWS TO HAVE FROSTED FILM APPLIED TO GLAZING QUARTZ LIP, SS-14" 3" 1' - 0 " GYP WALLS TO BE PAINTED, PT-5 PORCELAIN WALL TILE, PWT-1 2X TILED SHOWER NICHES, TILE TO MATCH ADACENT WALL SILL AT NICHE TO BE WPT-1 WALL CAP TO BE, SS-1 SHOWER BENCH TOP, SS-1 SHOWER BENCH TO BE TILED TO MATCH ADJACENT WALLS G 5 A 5.01 Sim 1' - 6 " 1' - 0 " 1' - 0 " 4" WALL TO BE TILED, PWT-1 3" WOOD LOOK PORCELAIN TILE STILL MITERED EDGE, TYP. 1/ 2 " WALL TO BE TILED, PWT-1 WOOD LOOK PORCELAIN TILE STILL MITERED EDGE, TYP. 1/ 2 " LED STRIP LIGHT, LED-1 LED STRIP LIGHT, LED-1 WALL TO BE TILED, PWT-1 1/2" QUARTZ COUNTERTOP, SS-1 BENCH FACE TO BE TILED, PWT-1 1/2" 1' - 6 " WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 5 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 5 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:25 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 ENLARGED PLANS & INTERIOR ELEVATIONS A 5.01 <S E T P H A S E > 935 CS AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 1/2" = 1'-0"A 5.01 1 ENLARGED PLAN - LEVEL 3 BATHROOM 1/2" = 1'-0"A 5.01 2 LEVEL 3 BATHROOM - EAST ELEVATION 1/2" = 1'-0"A 5.01 3 LEVEL 3 BATHROOM - SOUTH ELEVATION 1/2" = 1'-0"A 5.01 4 LEVEL 3 BATHROOM - WEST ELEVATION RESTROOM PLUMBING FIXTURE & ACCESSORIES SCHEDULE TAG DESCRIPTION MANUFACTURE MODEL # COMMENTS PROVIDED BY A UNDERMOUNT SINK TBD TBD COORDINATE WITH VANITY TOP BY CLIENT B FAUCET TBD TBD COORDINATE WITH VANITY TOP BY CLIENT C 48" VANITY TBD TBD SOLID WOOD WITH STONE TOP BY CLIENT D GLASS SHOWER ENCLOSURE TBD TBD BY CLIENT E 60" TUB TBD TBD BY CLIENT F SHOWER HEAD & SHOWER THERMOSTATIC TBD TBD BY CLIENT G TOILET TBD TBD BY CLIENT H TP HOLDER TBD TBD BY CLIENT I 30" - 36" TOWEL BAR TBD TBD BY CLIENT J 30"D BACKLIT MIRROR TBD TBD BY CLIENT K HAND TOWEL HOLDER TBD TBD BY CLIENT L 60" VANITY TBD TBD SOLID WOOD WITH STONE TOP BY CLIENT M UNDERMOUNT SINK TBD TBD COORDINATE WITH VANITY TOP BY CLIENT N FAUCET TBD TBD COORDINATE WITH VANITY TOP BY CLIENT O 30" X 48" MIRROR TBD TBD BY CLIENT P GLASS SHOWER ENCLOSURE TBD TBD BY CLIENT Q SHOWER HEAD & SHOWER THERMOSTATIC TBD TBD BY CLIENT R RAIN SHOWER HEAD/ SECOND SHOWER HEAD TBD TBD STYLE TO MATCH Q BY CLIENT S TP HOLDER TBD TBD BY CLIENT T 30" - 36" TOWEL BAR TBD TBD BY CLIENT U HAND TOWEL HOLDER TBD TBD BY CLIENT 1 1/2" = 1'-0"A 5.01 5 DETAIL - BATHROOM SHOWER NICHE STACKED N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 DW UP UP UP FINISH LEGEND LOCATION OF FLOORING TRANSITION FINISH TAG ROOM FINISH INDICATOR NIC -NOT IN CONTRACT ROOM NAME ROOM # X X X WALL FINISH WALL BASE FINISH FLOOR FINISH SYMBOL DEFINITION WT-1 FINISH NOTES 1. REFER TO GENERAL CONDITIONS, SPECIFICATIONS AND SCHEDULES FOR ALL WORK 2. DRAWINGS LISTED UNDER THE "DRAWING LIST" MUST READ IN CONJUNCTION WITH THE DRAWING FOR COMPLETE INFORMATION. 3. CONFIRM WITH ARCHITECT THAT THESE DRAWINGS ARE THE MOST CURRENT ISSUE BEFORE LAYOUT & CONSTRUCTION 4. EXCEPTIONS TO SPECIFICATIONS WILL BE NOTED IN LEGEND OR DRAWINGS. 5. REFER TO DRAWINGS FOR EXACT LOCATIONS, STOPS, STARTS AND PATTERNS OF MATERIALS. 6. ALL NEW DOORS & TRIM TO MATCH EXISTING. 7. ALL GWB CEILINGS AND SOFFITS TO BE PAINTED WHITE, FLAT FINISH, UNLESS OTHERWISE NOTED, REFER TO RCP. 8. *ALL WALL PAINT SHALL BE EGGSHELL *WD DOORS AND DOOR FRAMES TO BE PAINTED SEMI GLOSS UNLESS OTHERWISE NOTED. *ALL PAINTS TO BE LOW VOC 9. ALL RESILIENT BASE TO BE STRAIGHT AT CARPET AND COVE AT HARD FLOORING. 10. FLOORING MATERIAL CHANGES TO OCCUR BENEATH FOOR LEAF WHEN CLOSED, REFER TO TRANSITION DETAILS FOR ADDITIONAL INFORMATION. 11. START FLOORING MATERIALS WITH PATERNS, GRID OR REPEATS CENTER OF THE ROOM, UNLESS OTHERWISE NOTED. 12. ALL ACCESS/ELECTICAL PANELS TO BE PAINTED WITH APPORIATE PRODUCT TO MATCH THE WALL IT IS LOCATED ON. 13. REFER TO ELEVATION AND FINISH SCHEDULE FOR ADDITIONAL INFORMATION AND DETAILS. 14. DETAILS KEYED AT TYPICAL LOCATIONS APPLY TO ALL LOCATIONS NOT KEYED WITHIN THE SCOPE OF WORK. IF DISCREPANCIES OCCUR AND/OR CLARIFICATION IS REQUIRED, GC IS TO NOTIFY THE ARCHITECT 15. FINISHES CONTINUE INTO CLOSETS WITHIN ROOMS/SPACES SHARING ROOM NUMBERS. KITCHEN EX EX PT-1 BATHROOM FT-1 PWT-1 PT-3 LAUNDRY ROOM EX WB-1 PT-2 F1 F2 WT-1 F5 F6 DINING ROOM LIVING ROOM BEDROOM 1 BEDROOM 2 PRIMARY BEDROOM BATHROOM FT-3 PWT-1 PT-5 F3 F4 F8 WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 6 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 6 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:26 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 FINISH PLAN - LEVEL 2 & 3 A 7.00 <S E T P H A S E > 935 CS AC CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 KEY NOTES_FINISH F1 EXISTING TILE TO BE FINISHED, GC TO COORDINATE WITH CLIENT BEFORE EQUIPMENT INSTALLATION F2 GC TO INSTALL TILE BORDER USING FT-2,SEE GREY HATCH FOR DESIRED PATTERN & PLACEMENT F3 GC TO INSTALL TILE BORDER USING FT-4, SEE GREY HATCH FOR DESIRED PATTERN & PLACEMENT F4 EXISTING SLOPED CEILING TO BE PAINTED PT-4. EXPOSED STRUCTURE FINISH TO REMAIN F5 ENTIRE LIVING ROOM TO BE PAINTED, PT-6 OR WALLPAPERED. GC TO COORDIANTE FINAL PAINT/ WALLPAPER SELECTION F6 BEDROOM 2 TO BE REPAINTED, PT-7 F8 NEW WALLS AND FINISHED LEDGE TO BE PAINTED, PT-8. 1/4" = 1'-0"A 7.00 1 FINISH PLAN - LEVEL 2 1/4" = 1'-0"A 7.00 2 FINISH PLAN - LEVEL 3 FINISH SCHEDULE MARK DESCRIPTION MANUFACTURER MODEL # SIZE FINISH/COLOR INSTALLATION COMMENTS BB-1 WOOD COUNTERTOP PROVIDED BY GC CLIENT TO SELECT FINISH FT-1 1.5" X 1.5" HEXIGON MOSAIC TILE GARDEN STATE TILE HEXA - AEGEAN BLUE 1.5" X 1.5" MATTE GROUT: LATICRETE - 09 FROSTY GC TO CHECK IN WITH CLIENT BEFORE PURCHASING TILE FOR FINAL COLOR APPROVAL FT-2 1.5" X 1.5" HEXIGON MOSAIC TILE GARDEN STATE TILE HEXA - LEMON SORBET 1.5" X 1.5" MATTE GROUT: LATICRETE - 09 FROSTY FT-3 2" X 2" HEXIGON MOSAIC TILE BEDROSIANS LE CAFE HEXAGON PORCELAIN MOSAIC - WHITE 2" X 2" MATTE GROUT: LATICRETE - 09 FROSTY FT-4 2" X 2" HEXIGON MOSAIC TILE BEDROSIANS LE CAFE HEXAGON PORCELAIN MOSAIC - BLACK 2" X 2" MATTE GROUT: LATICRETE - 09 FROSTY PT-1 WALL PAINT (KITCHEN) TBD TBD - - - GC TO CHECK IN WITH CLIENT FOR PAINT COLOR SELECTION PT-2 WALL PAINT (LAUNDRY ROOM) TBD TBD - - - GC TO CHECK IN WITH CLIENT FOR PAINT COLOR SELECTION PT-3 WALL PAINT (BATHROOM) BENJAMIN MOORE PURE WHITE OC-64 - EGGSHELL - GC TO CHECK IN WITH CLIENT FOR FINAL APPROVAL BEFORE INSTALLATION PT-4 WALL PAINT (PRIMARY BEDROOM) TBD TBD - -GC TO CHECK IN WITH CLIENT FOR PAINT COLOR SELECTION PT-5 WALL PAINT (BATHROOM) BENJAMIN MOORE SYCAMORE CC-350 - EGGSHELL WALLS & CEILING GC TO CHECK IN WITH CLIENT FOR FINAL APPROVAL BEFORE INSTALLATION PT-6 WALL PAINT (LIVING ROOM) TBD TBD - - - GC TO CHECK IN WITH CLIENT FOR ANY CHANGES TO PAINT COLOR SELECTION/ IF CHANGING TO WALLPAPER PT-7 WALL PAINT (BEDROOM 2) TBD TBD - - - GC TO CHECK IN WITH CLIENT FOR FINAL APPROVAL BEFORE INSTALLATION PT-8 WALL PAINT (STAIRWELL) TBD TBD - - - GC TO CHECK IN WITH CLIENT FOR PAINT COLOR SELECTION SS-1 QUARTZ COUNTERTOP CAESARSTONE 500 H - HONED GC TO COORDINATE WITH CLIENT ON MATCHING COUNTERTOPS OF VANITIES WB-1 WOOD WALL BASE MATCH EXISTING WD-1 WOOD FINISH FOR CASEWORK TO MATCH BB-1 WPT-1 WOOD LOOK PORCELAIN TILE TBD TBD 4" WIDE AT LEAST FINISH TO BE CLOSEST MATCH TO VANITY WOOD FINISH AT SHOWER & WALL NICHES SEE DETAIL ON SHEETS A5.00 & A5.01 WT-1 MOSAIC WALL TILE DALTILE REVALIA REMIX - CALMING WHITE RV13 1" X 4" PICKET GLOSSY GROUT: LATICRETE - 44 BRIGHT WHITE WT-1 N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 S S ASD S ASD S ASD GENERAL NOTES AND LEGENDS POWER NOTES 1. REFER TO GENERAL DEMOLITION NOTES FOR ADDITIONAL REQUIREMENTS. 2. RECEPTACLES, SWITCHES AND DEVICES SHALL BE INSTALLED AT MOUNTING HEIGHTS AND LOCATIONS AS INDICATED ON THE ARCHITECTURAL ELEVATIONS, PART PLANS AND DETAILS. CONTRACTOR SHALL REFER TO THE ARCHITECTURAL DRAWINGS FOR INFORMATION. 3. CIRCUIT NUMBERS ARE SHOWN FOR DESCRIPTIVE PURPOSES ONLY. EXACT NUMBERS SHALL BE DETERMINED IN FIELD AND SHALL BE NOTED ON THE CONTRACTORS AS-BUILT DRAWINGS. 4. COORDINATE EXACT LOCATION OF ALL MECHANICAL EQUIPMENT WITH HVAC, PLUMBING AND FIRE PROTECTION DRAWINGS. 5. CONDUITS AND LIGHT FIXTURE CHAINS WILL BE MASK OFF AND PROTECT FROM BEING PAINTED OVER. 6. GC TO PROTECT ALL CAT 5E AND ANY OTHER POWER DEVICE WIRES CLOSE TO CEILING PRIOR TO PAINTING. 7. ALL LIGHTS TO BE INSTALLED ON DIMMERS. LIVING ROOM BEDROOM 1 BEDROOM 2 BATHROOM DINING ROOM KITCHEN LAUNDRY ROOM 3' - 0 " EX EX EX EX EX R1 EX EX EX R1 R1 R1 F1 1' - 3 " LED1 LED1 R1 R1 R1 R1 1' - 2 " LED1 CF1 S1 S1 BATHROOM PRIMARY BEDROOM WARNING: Joe The Architect, Inc., all drawings and written material herein constitute the original and unpublished work of the architect, and the same may not be duplicated, used, or disclosed without the written consent of the architect. Contractors to use Architectural drawings for set out. Contractors to check and verify all Dimensions on Site prior to Construction/Fabrication. Figured Dimensions take precedence over Scaled Dimensions. Any discrepancies should be immediately referred to the Architect. The project manager shall be notified in writing of any discrepancies prior to proceeding with the work. The scale of drawings may change when copied or faxed. All work to comply with I.B.C. Regulations and relevant American Standards. © 2021- all rights reserved FOR PERMIT CLIENT SEAL CONSULTANT KEY PLAN PROJECT INFORMATION ISSUE CHART SHEET NUMBER SHEET NAME SCALE APPROVED CHECKED PROJECT NUMBER DESIGN FIRM Joe The Architect, LLC 343 Medford Street, Suite 4C Somerville, MA 02145 t: +1(617) 764-3593 e: askjoe@joethearchitect.com www.joethearchitect.com 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 6 P M 7/ 1 7 / 2 0 2 5 4 : 2 1 : 2 6 P M C: \ U s e r s \ c w o o d s \ D o c u m e n t s \ 9 3 5 9 5 B o s t o n R e s c a n C E N T RA L _ c a m i l l e J P C 3 B . r v t As indicated 7/17/2025 4:21:26 PM 95 BOSTON RESIDENCE 95 BOSTON ST. SALEM, MA 01970 SWITCHING PLAN - LEVEL 2 & 3 A 7.30 <S E T P H A S E > 935 Checker Approver CHELSEA & DEVIN MCDONALD 95 BOSTON ST. SALEM, MA 01970 1/4" = 1'-0"A 7.30 1 SWITCHING PLAN - LEVEL 2 1/4" = 1'-0"A 7.30 2 SWITCHING PLAN - LEVEL 3 E1 KEY NOTES_POWER E1 LIGHT HAVE DOOR JAMB SWITCH N ISSUE DATE 1 ISSUED FOR PERMIT 07/17/25 CS AC