Loading...
13 CHESTNUT STREET_CofA_WINDOWS_CHIMNEY Salem Historical Commission 98 WASHINGTON STREET, SALEM, MASSACHUSETTS 01970 (978) 619-5685 CERTIFICATE OF APPROPRIATENESS It is hereby certified that the Salem Historical Commission has determined that the proposed:  Construction  Moving  Reconstruction ✓ Alteration ✓ Demolition  Painting  Signage  Other work as described below will be appropriate to the preservation of said Historic District, as per the requirements set forth in the Historic District's Act (M.G.L. Ch. 40C) and the Salem Historic Districts Ordinance. District: McIntire Address of Property: 13 Chestnut Street Name of Record Owner: Jennifer Rousseau and Nick Kiefer (Judianne Brugger new owner) Description of Approval of Work: ▪ Replace three (3) first story windows on rear elevation with new 6/6 double hung, true-divided, single pane wood windows to match existing dimensions, trim, material, and details of original windows on house per attached images; and ▪ Remove rear exterior chimney per attached images. Approval granted for chimney removal due to fact that chimney is not character defining and was constructed for utilitarian purpose at rear of building Dated: December 22, 2025 SALEM HISTORICAL COMMISSION By: The homeowner has the option not to commence the work (unless it relates to resolving an outstanding violation). All work commenced must be completed within one year from this date unless otherwise indicated. THIS IS NOT A BUILDING PERMIT. All applicable building permits to be obtained prior to work commencing Location of building alterations Existing conditions on rear elevation Approved changes to rear elevation 13 Chestnut Street Existing Conditions South Elevation 11.25.2025 Perspective View 13 Chestnut Street Proposed Changes South Elevation 11.25.2025 Perspective View New windows at first floor South Elevation to match size and style of existing second floor windows above. See window maker’s detail drawings. 
 NOTES: 1.This conceptual plan is illustrative of suggested alterations and must be examined and verified by certified professionals/General Contractor/subcontractors prior to any work. 2.Any planned work relating to the health and safety of the occupants and the public must be authorized by certified engineers (i.e. structural, mechanical, etc.) hired by others and by regulating agencies. 3.Field measurements and existing conditions must be verified by the General Contractor prior to the commencement of any work and reported . CONCEPTUAL DRAWING FOR PRICING (Not for Construction) 13 Chestnut Street - Proposed Window Changes 1/4” = 1-0” November 25, 2025 
 CONCEPTUAL DRAWING FOR PRICING (Not for Construction) NOTES: 1.This conceptual plan is illustrative of suggested alterations and must be examined and verified by certified professionals/General Contractor/subcontractors prior to any work. 2.Any planned work relating to the health and safety of the occupants and the public must be authorized by certified engineers (i.e. structural, mechanical, etc.) hired by others and by regulating agencies. 3.Field measurements and existing conditions must be verified by the General Contractor prior to the commencement of any work and reported . RESIDENCE at 13 CHESTNUT STREET, SALEM PRELIMINARY KITCHEN ELEVATIONS Sink Wall October 29, 2025 1/2” = 1’ - 0” A. This drawing represents approximate height of existing windows. Window heights/locations to be reviewed following demolition of existing interior finishes. Window at the range area should align with existing window above at second floor 13 Chestnut Street - Proposed Window Changes 1/2” = 1-0” November 25, 2025 RECIPIENT: Red Phoenix Construction 13 Chestnut Street Salem, Massachusetts 01970 Phone: 978-833-8961 SENDER: Window Woman of New England 44R Elm Street Amesbury, Massachusetts 01913 Phone: 1-978-532-2070 Email: Info@window-woman-ne.com Website: https://www.window-woman.com/ Product/Service Description Qty.Unit Price Total Custom Build Build new sash to replace leaded windows in first floor kitchen. Fabricate new six-over-six sash to fit opening, with jambs and exterior trim. Glaze sash with antique glass. Prime only (no finish paint) on interior and exterior sash, jambs, and trim. Price includes delivery but no sash pulls or installation. 4 $3,875.00 $15,500.00* * Non-taxable Subtotal $15,500.00 No Tax Sales (0.0%)$0.00 Total $15,500.00 Lead time for replica sash would be about six to eight weeks. This quote is valid for the next 6 months. The price named in the quote is a good faith estimate based on an initial evaluation. The actual cost may change once the windows have been evaluated in greater detail. The client will be informed as soon as possible of any changes in cost. Changes requested by the client to quantities or scope of work may lead to additional charges and changes to the project timeline. We are committed to your satisfaction, and we stand behind the quality of our work. We will use our best efforts to perform our obligations under this agreement. Often the fit of windows changes from season to season, we are always happy to tweak the fit in the first year after work is completed at no additional charge. We do not use chemical paint strippers, only heat, steam, and manual removal. We practice safe lead paint handling and removal processes. Our team has completed the EPA RPP certification training and we have received our Certification to Conduct Lead Based Paint Activities and Renovations. Window Woman of New England was established in 2003. A list of references is available on request. Home Improvement Contractor registration #166056. We are fully insured. 1 of 2 pages ESTIMATE #860 SENT ON: Nov 20, 2025 Signature: _____________________ Date: _____________ 2 of 2 pages ESTIMATE #860 SENT ON: Nov 20, 2025 Inspected by: Stephen Verbeek Lic #601 888-808-2566 Home Inspection Report 13 Chestnut St Salem, Ma 01970 Prepared for: Judianne Brugger Roof Recommend consulting the seller, broker, association or roofer to determine or confirm roof age and any known issues. NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection S Satisfactory Item is functioning as originally intended with no visible defect. NP Not Present Item not present or not found. NR Not Rated Item not rated due to lack of power, turned off, in an unworkable condition, not visible or partially visible at time of inspection. A Advisory Item is not functioning as originally intended and may show visible defects. Consultation with the appropriate tradesperson is recommended. S NP NR A Main Roof Surface Method of Inspection: Binoculars (12x25), Walked On Flat Section Type: Pitched Approx Age: Unknown Material: Asphalt Shingles, Rubber Membrane - Limited visual access due to roof design, trees and surrounding homes. A full evaluation of the roof could not be made. Recommend consulting a roofer for a more thorough evaluation. Unable to identify number of roof layers present. Recommend no more than two roofing layers be present. Consult a roofer as needed. Trim back tree branches from roof. Remove any debris which may be present and inspect for damage. Manufacturers of asphalt shingles, on average, provide a fifteen to twenty year lifespan. Do not confuse this with actual roof life as predicting this is not possible due to numerous factors. Manufacturers of synthetic rubber membrane roofs, on average, provide a twenty year lifespan. Do not confuse this with actual roof life as predicting this is not possible due to numerous factors. Plumbing Vents: PVC Flashing: Flashing should be inspected yearly. Limited visual access. See notes on roofing material. Roof, Side of House Chimney Chimney(s) (excluding liners): Brick - Many municipalities require the presence of a flue liner when using certain flues. Consult local building authorities for more information. Recommend installing rain cap/spark arrestor at top of chimney(s). Chimney at rear appears to have settled away from home. Gaps are noted between brick and home and will allow for water penetration. Areas crumbling and deteriorated. Areas crumbling and deteriorated. Areas need repointing. Painting brick is destructive to the material. A lyme wash is a better alternative. Consult a mason. Talon Home Inspection 5 of 22 Palm-Tech Inspector, Copyright © 1998-2025, Palm-Tech Talon Home Inspection Kitchen (Continued) Ceiling: Drop - Areas cracked and/or sagging. Windows: Window(s) are deteriorated and appear to be at or approaching the end of their lifespan. It's not unreasonable to expect replacement soon. Doors: Ventilator: Disposal: Dishwasher: Stove Top/Oven: Induction unit. Unable to test. Check at walkthrough. HVAC Source: Diffuser, 90-100 Degrees Bathroom NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection S Satisfactory Item is functioning as originally intended with no visible defect. NP Not Present Item not present or not found. NR Not Rated Item not rated due to lack of power, turned off, in an unworkable condition, not visible or partially visible at time of inspection. A Advisory Item is not functioning as originally intended and may show visible defects. Consultation with the appropriate tradesperson is recommended. S NP NR A 1st Floor Bathroom Type of Bath: 1/2 Bath 3/4 Bath Full Bath Master Bath Outlets: Sink: Ventilator: Counter/Cabinet: Tub/Surround: Shower/Surround: Toilet: Loose toilet noted. Remove, check wax ring, repair and re-fasten. Floors: Tile Walls: Gypsum-based Talon Home Inspection 16 of 22 Palm-Tech Inspector, Copyright © 1998-2025, Palm-Tech Talon Home Inspection