22 Prescott Street_WDDO
Salem Historical Commission
98 WASHINGTON STREET, SALEM, MASSACHUSETTS 01970
(978) 619-5685
WAIVER OF THE DEMOLITION DELAY ORDINANCE
It is hereby certified that the Salem Historical Commission has waived the Demolition Delay Ordinance
for the proposed demolition as described below, as per the requirements set forth in the Historic District's
Act (M.G.L. Ch. 40C) and the Salem Historic Districts Ordinance.
Address of Property: 22 Prescott Street
Name of Record Owner: Arsenio Delarosa
Description of Demolition Work Proposed:
Demolish more than 50% of roof on building older than 50 years.
Per the Demolition Delay Ordinance, the Commission made the following findings:
1) The Commission voted unanimously to find the building not historically significant.
Dated: August 6, 2025 SALEM HISTORICAL
COMMISSION
By:
THIS IS NOT A DEMOLITION OR BUILDING PERMIT. Please be sure to obtain the
appropriate permits from the Inspector of Buildings (or any other necessary permits or approvals)
prior to commencing work.
APPLICABLE CODES:
2021 INTERNATIONAL RESIDENTIAL CODE2021 INTERNATIONAL MECHANICAL CODE2021 PLUMBING CODE2021 INTERNATIONAL ENERGY CODECITY OF SALEM ZONING ORDINANCE
BUILDING CONSTRUCTION:
ROOF - WOOD FRAME W/ ASPHALT SHINGLES ROOFINGFLOOR - WOOD FRAME EXTERIOR WALLS - VINYL SIDING, PVC TRIM W/ STUD BACKUPINTERIOR WALLS - WOOD STUD W/ BLUEBOARD & PLASTER FINISH
BUILDING INFORMATION:
1.
2.
3.
4.
5.
6.
7.
8.
9.
GENERAL NOTES:
CONSTRUCTION TO BE IN ACCORDANCE WITH THE MA (STATE) BUILDING CODE, NINTH EDITION (FOR ONE & TWO FAMILY DWELLINGS) (MA) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC 2021).
THE CONTRACTOR IS RESPONSIBLE FOR ALL LABOR, MATERIALS, MEANS, AND METHODS OF CONSTRUCTION ASSOCIATED WITH THIS PROJECT.
CONTRACTOR SHALL CONFIRM ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE DRAWINGS.
THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE CONTRACT DRAWINGS, ANY DISCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER OR ENGINEER BEFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUBSTITUTIONS OF STRUCTURAL MATERIAL OR DETAILS FROM THOSE DEPICTED ON THE DRAWINGS MAY BE MADE ONLY WITH THE PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION, OR INSTALLATION.
CONTRACTOR SHALL MAINTAIN SMOKE FREE PREMISES CLEAN AND FREE OF ALL TRASH DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILILNG, PAINT OVERSPRAY, ETC. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON CMPLETIOTN OF THE PROJECT.
ALL MANUFACTURER'S PRINTED WARNINGS FOR HANDLING OF PRODUCTS MUST BE STRICTLY OBSERVED. SAVE ALL MATERIAL FOR OWNER.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB SAFETY DURING CONSTRUCTION INCLUDING BUT NOT LIMITED TO SHEETING, SHORING, AND GUYING STRUCTURES, BARRIERS, AND SIGNAGE.
DO NOT SCALE THE DRAWINGS. DIMENSION STRINGS HAVE BEEN PROVIDED AND REPRESENT THE ACTUAL MEASUREMENT AS NOTED.
LOCATIONS IS SEATING ON ZONING "R-AG" -RES/AGR DIST
ZONING REQUIREMENTS:
FRONT SETBACKS 15'-0"
REAR SETBACKS 30'-0"
SIDE SETBACKS 10'-0"
BUILDING HEIGHT 35'-0"
REQUIRED:PROPOSED:ZONING REQUIREMENTS:
MAX. BUILDING COVERAGE 30%
MAX. NUMBER OF STORIES 2.5 STORIES
SHEET INDEX
A0.0 COVER SHEET & PROJECT INFORMATION
A0.1 GENERAL INFORMATION
AEXST1.1 EXISTING - BASEMENT & 1ST FLOOR PLAN
AEXST1.2 EXISTING 2ND & ATTIC FLOOR PLAN
AEXST1.3 EXISTING-TOP OF ROOF
AEXST 2.1 EXISTING LEFT & RIGHT EXTERIOR ELEVATIONS
AEXST 2.2 EXISTING FRONT & REAR ELEVATIONS
DM1.0 DEMOLITION PLAN - BASEMENT & 1ST FLOOR
DM1.1 DEMOLITION PLAN - 2ND & 3RD FLOOR
A1.0 PROPOSED - BASEMENT & 1ST FLOOR PLAN
A1.1 PROPOSED 2ND & ATTIC FLOOR PLAN
A1.2 PROPOSED TOP OF ROOF
A2.0 PROPOSED FRONT & REAR EXTERIOR ELEVATIONS
A2.1 PROPOSED LEFT & RIGHT EXTERIOR ELEVATIONS
A3.0 PERSPECTIVE VIEWS
A3.1 PERSPECTIVE VIEWS 2
LOCUS MAP
22 Prescott St, Salem, MA 01970
CLIENT:
24 x 36
Date
CONTRACTOR:DESIGNER:
5/24/2025 3:37:08 PM
PROP. NEW DORMERS &INT.RENOVATION
PROP. NEW DORMERS & INT.RENOVATION
05/24/2025
22 Prescott St, Salem, MA 01970
EXISTING CONDITION
05/24/2025
Arsenio Delarosa
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
Arsenio.dlr@gmail.comPHONE# 978-979-8600
DELAROSA CONSTRUCTION
?
LUX DESIGN GROUP
51 Main Street Topsfield, MA 01983Phone # 774-386-3441
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
2 EXISTING AXONOMETRIC VIEW 1 PROPOSED AXONOMETRIC VIEW
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
PROPOSED 3 STORIES
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
Scale
Date
5/24/2025 3:37:17 PM
1/4" = 1'-0"
AEXST 2.1
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
EXISTING LEFT & RIGHTEXTERIOR ELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1/4" = 1'-0"2 EXISTING REAR ELEVATION
1/4" = 1'-0"1 EXISTING FRONT ELEVATION
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
1/4" = 1'-0"2 EXISTING RIGHT ELEVATION
1/4" = 1'-0"1
EXISTING LEFT ELEVATION
Scale
Date
5/24/2025 3:37:13 PM
1/4" = 1'-0"
AEXST 2.2
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
EXISTING FRONT & REARELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1.
2.
3.
4.
PROVIDE ALL NECESSARY STRUCTURAL BLOCKING AND RELATED WORK FOR DOOR, FRAME, AND HARDWARE INSTALLATION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
NO THROUGH-BOLTING WILL BE ACCEPTED. DOOR TO BE REINFORCED INTERNALLY.
ALL DOORS SHALL BE NEW WOOD FINISH DOORS. THICKNESS TO BE 1-3/4" EXCEPT WHERE NOTED.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECT REVIEW AND APPROVAL PRIOR TO ORDERING.
GENERAL DOOR NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
ALL SILLS TO BE HISTORIC PROFILE: 2"+. EXTEND TO OUTSIDE OF CASING OR AS INDICATED ON DRAWINGS.
ALL MULLIONS TO BE 7/8" SIMULATED DIVIDED LIGHTS WITH SHADOW BARS.
ALL DOUBLE HUNG (CASEMENT AND AWNING TO HAVE FULL SCREENS) WITH HI TRANSPARENCY MESH.
PROVIDE CORRECT JAMB EXTENSIONS AS REQUIRED FOR WALL THICKNESS.
REFER TO EXTERIOR ELEVATIONS FOR MUNTIN LAYOUT.
EXTERIOR JAMB TRIM TO BE 5/4" X 5" OR AS INDICATED ON DRAWINGS.
ALL GLASS TO BE INSULATING, LOW E 368 WITH ARGON, TEMPER WHERE REQUIRED BY CODE.
MODEL NUMBERS AND ROUGH OPENINGS ARE FOR (MANUFACTURER/SERIES) UNLESS OTHERWISE NOTED. HEAD R.O. INDICATED ON SCHEDULE UNLESS NOTED OTHERWISE ON DRAWINGS. SUBSTITUTE WINDOWS TO MEET ENERGY CODE AND MATCH MANUFACTURER ATTRIBUTES.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECTURE REVIEW PRIOR TO ORDERING.
GENERAL WINDOW NOTES:
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR
18' - 4"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
EGRESS
WINDOW
EGRESS
WINDOW
EGRESS
WINDOW
THE SCOPE OF WORK
EXISTING 1ST FLOOR
0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR18' - 4"
GROUND LEVEL-1' - 10"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
EGRESS
WINDOW
EGRESS
WINDOW
EGRESS
WINDOW
EGRESS
WINDOW
THE SCOPE OF WORK
THE SCOPE
OF WORK
1/4" = 1'-0"2 PROPOSED FRONT ELEVATION
Scale
Date
5/24/2025 3:37:24 PM
1/4" = 1'-0"
A2.0
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PROPOSED FRONT &REAR EXTERIORELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1/4" = 1'-0"1 PROPOSED REAR ELEVATION
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR
18' - 4"
GROUND LEVEL
-1' - 10"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
THE SCOPE OF WORK
1.
2.
3.
4.
5.
6.
7.
8.
9.
ALL SILLS TO BE HISTORIC PROFILE: 2"+. EXTEND TO OUTSIDE OF CASING OR AS INDICATED ON DRAWINGS.
ALL MULLIONS TO BE 7/8" SIMULATED DIVIDED LIGHTS WITH SHADOW BARS.
ALL DOUBLE HUNG (CASEMENT AND AWNING TO HAVE FULL SCREENS) WITH HI TRANSPARENCY MESH.
PROVIDE CORRECT JAMB EXTENSIONS AS REQUIRED FOR WALL THICKNESS.
REFER TO EXTERIOR ELEVATIONS FOR MUNTIN LAYOUT.
EXTERIOR JAMB TRIM TO BE 5/4" X 5" OR AS INDICATED ON DRAWINGS.
ALL GLASS TO BE INSULATING, LOW E 368 WITH ARGON, TEMPER WHERE REQUIRED BY CODE.
MODEL NUMBERS AND ROUGH OPENINGS ARE FOR (MANUFACTURER/SERIES) UNLESS OTHERWISE NOTED. HEAD R.O. INDICATED ON SCHEDULE UNLESS NOTED OTHERWISE ON DRAWINGS. SUBSTITUTE WINDOWS TO MEET ENERGY CODE AND MATCH MANUFACTURER ATTRIBUTES.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECTURE REVIEW PRIOR TO ORDERING.
GENERAL WINDOW NOTES:
1.
2.
3.
4.
PROVIDE ALL NECESSARY STRUCTURAL BLOCKING AND RELATED WORK FOR DOOR, FRAME, AND HARDWARE INSTALLATION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
NO THROUGH-BOLTING WILL BE ACCEPTED. DOOR TO BE REINFORCED INTERNALLY.
ALL DOORS SHALL BE NEW WOOD FINISH DOORS. THICKNESS TO BE 1-3/4" EXCEPT WHERE NOTED.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECT REVIEW AND APPROVAL PRIOR TO ORDERING.
GENERAL DOOR NOTES:
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR
18' - 4"
GROUND LEVEL
-1' - 10"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
THE SCOPE OF WORK
1/4" = 1'-0"1 PROPOSED LEFT ELEVATION
Scale
Date
5/24/2025 3:37:30 PM
1/4" = 1'-0"
A2.1
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PROPOSED LEFT & RIGHTEXTERIOR ELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1/4" = 1'-0"2 PROPOSED RIGHT ELEVATION
2 FRONT-LEFT PERSPECTIVE VIEW
1 REAR-RIGHT PERSPECTIVE VIEW
Scale
Date
5/24/2025 3:37:42 PM
A3.0
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PERSPECTIVE VIEWS
05/24/2025
22 Prescott St, Salem, MA 01970
Scale
Date
5/24/2025 3:37:56 PM
A3.1
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PERSPECTIVE VIEWS 2
05/24/2025
22 Prescott St, Salem, MA 01970
1 FRONT-RIGHT PERSPECTIVE VIEW
2 REAR-LEFT PERSPECTIVE VIEW
APPLICABLE CODES:
2021 INTERNATIONAL RESIDENTIAL CODE2021 INTERNATIONAL MECHANICAL CODE2021 PLUMBING CODE2021 INTERNATIONAL ENERGY CODECITY OF SALEM ZONING ORDINANCE
BUILDING CONSTRUCTION:
ROOF - WOOD FRAME W/ ASPHALT SHINGLES ROOFINGFLOOR - WOOD FRAME EXTERIOR WALLS - VINYL SIDING, PVC TRIM W/ STUD BACKUPINTERIOR WALLS - WOOD STUD W/ BLUEBOARD & PLASTER FINISH
BUILDING INFORMATION:
1.
2.
3.
4.
5.
6.
7.
8.
9.
GENERAL NOTES:
CONSTRUCTION TO BE IN ACCORDANCE WITH THE MA (STATE) BUILDING CODE, NINTH EDITION (FOR ONE & TWO FAMILY DWELLINGS) (MA) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC 2021).
THE CONTRACTOR IS RESPONSIBLE FOR ALL LABOR, MATERIALS, MEANS, AND METHODS OF CONSTRUCTION ASSOCIATED WITH THIS PROJECT.
CONTRACTOR SHALL CONFIRM ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE DRAWINGS.
THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE CONTRACT DRAWINGS, ANY DISCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER OR ENGINEER BEFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUBSTITUTIONS OF STRUCTURAL MATERIAL OR DETAILS FROM THOSE DEPICTED ON THE DRAWINGS MAY BE MADE ONLY WITH THE PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION, OR INSTALLATION.
CONTRACTOR SHALL MAINTAIN SMOKE FREE PREMISES CLEAN AND FREE OF ALL TRASH DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILILNG, PAINT OVERSPRAY, ETC. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON CMPLETIOTN OF THE PROJECT.
ALL MANUFACTURER'S PRINTED WARNINGS FOR HANDLING OF PRODUCTS MUST BE STRICTLY OBSERVED. SAVE ALL MATERIAL FOR OWNER.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB SAFETY DURING CONSTRUCTION INCLUDING BUT NOT LIMITED TO SHEETING, SHORING, AND GUYING STRUCTURES, BARRIERS, AND SIGNAGE.
DO NOT SCALE THE DRAWINGS. DIMENSION STRINGS HAVE BEEN PROVIDED AND REPRESENT THE ACTUAL MEASUREMENT AS NOTED.
LOCATIONS IS SEATING ON ZONING "R-AG" -RES/AGR DIST
ZONING REQUIREMENTS:
FRONT SETBACKS 15'-0"
REAR SETBACKS 30'-0"
SIDE SETBACKS 10'-0"
BUILDING HEIGHT 35'-0"
REQUIRED:PROPOSED:ZONING REQUIREMENTS:
MAX. BUILDING COVERAGE 30%
MAX. NUMBER OF STORIES 2.5 STORIES
SHEET INDEX
A0.0 COVER SHEET & PROJECT INFORMATION
A0.1 GENERAL INFORMATION
AEXST1.1 EXISTING - BASEMENT & 1ST FLOOR PLAN
AEXST1.2 EXISTING 2ND & ATTIC FLOOR PLAN
AEXST1.3 EXISTING-TOP OF ROOF
AEXST 2.1 EXISTING LEFT & RIGHT EXTERIOR ELEVATIONS
AEXST 2.2 EXISTING FRONT & REAR ELEVATIONS
DM1.0 DEMOLITION PLAN - BASEMENT & 1ST FLOOR
DM1.1 DEMOLITION PLAN - 2ND & 3RD FLOOR
A1.0 PROPOSED - BASEMENT & 1ST FLOOR PLAN
A1.1 PROPOSED 2ND & ATTIC FLOOR PLAN
A1.2 PROPOSED TOP OF ROOF
A2.0 PROPOSED FRONT & REAR EXTERIOR ELEVATIONS
A2.1 PROPOSED LEFT & RIGHT EXTERIOR ELEVATIONS
A3.0 PERSPECTIVE VIEWS
A3.1 PERSPECTIVE VIEWS 2
LOCUS MAP
22 Prescott St, Salem, MA 01970
CLIENT:
24 x 36
Date
CONTRACTOR:DESIGNER:
5/24/2025 3:37:08 PM
PROP. NEW DORMERS &INT.RENOVATION
PROP. NEW DORMERS & INT.RENOVATION
05/24/2025
22 Prescott St, Salem, MA 01970
EXISTING CONDITION
05/24/2025
Arsenio Delarosa
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
Arsenio.dlr@gmail.comPHONE# 978-979-8600
DELAROSA CONSTRUCTION
?
LUX DESIGN GROUP
51 Main Street Topsfield, MA 01983Phone # 774-386-3441
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
2 EXISTING AXONOMETRIC VIEW 1 PROPOSED AXONOMETRIC VIEW
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
PROPOSED 3 STORIES
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
Scale
Date
5/24/2025 3:37:17 PM
1/4" = 1'-0"
AEXST 2.1
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
EXISTING LEFT & RIGHTEXTERIOR ELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1/4" = 1'-0"2 EXISTING REAR ELEVATION
1/4" = 1'-0"1 EXISTING FRONT ELEVATION
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR
9' - 4"
EXISTING 3RD FLOOR18' - 4"
EXISTING TOP OF
ROOF LEVEL
29' - 8 7/8"
1/4" = 1'-0"2 EXISTING RIGHT ELEVATION
1/4" = 1'-0"1
EXISTING LEFT ELEVATION
Scale
Date
5/24/2025 3:37:13 PM
1/4" = 1'-0"
AEXST 2.2
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
EXISTING FRONT & REARELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1.
2.
3.
4.
PROVIDE ALL NECESSARY STRUCTURAL BLOCKING AND RELATED WORK FOR DOOR, FRAME, AND HARDWARE INSTALLATION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
NO THROUGH-BOLTING WILL BE ACCEPTED. DOOR TO BE REINFORCED INTERNALLY.
ALL DOORS SHALL BE NEW WOOD FINISH DOORS. THICKNESS TO BE 1-3/4" EXCEPT WHERE NOTED.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECT REVIEW AND APPROVAL PRIOR TO ORDERING.
GENERAL DOOR NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
ALL SILLS TO BE HISTORIC PROFILE: 2"+. EXTEND TO OUTSIDE OF CASING OR AS INDICATED ON DRAWINGS.
ALL MULLIONS TO BE 7/8" SIMULATED DIVIDED LIGHTS WITH SHADOW BARS.
ALL DOUBLE HUNG (CASEMENT AND AWNING TO HAVE FULL SCREENS) WITH HI TRANSPARENCY MESH.
PROVIDE CORRECT JAMB EXTENSIONS AS REQUIRED FOR WALL THICKNESS.
REFER TO EXTERIOR ELEVATIONS FOR MUNTIN LAYOUT.
EXTERIOR JAMB TRIM TO BE 5/4" X 5" OR AS INDICATED ON DRAWINGS.
ALL GLASS TO BE INSULATING, LOW E 368 WITH ARGON, TEMPER WHERE REQUIRED BY CODE.
MODEL NUMBERS AND ROUGH OPENINGS ARE FOR (MANUFACTURER/SERIES) UNLESS OTHERWISE NOTED. HEAD R.O. INDICATED ON SCHEDULE UNLESS NOTED OTHERWISE ON DRAWINGS. SUBSTITUTE WINDOWS TO MEET ENERGY CODE AND MATCH MANUFACTURER ATTRIBUTES.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECTURE REVIEW PRIOR TO ORDERING.
GENERAL WINDOW NOTES:
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR
18' - 4"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
EGRESS
WINDOW
EGRESS
WINDOW
EGRESS
WINDOW
THE SCOPE OF WORK
EXISTING 1ST FLOOR
0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR18' - 4"
GROUND LEVEL-1' - 10"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
EGRESS
WINDOW
EGRESS
WINDOW
EGRESS
WINDOW
EGRESS
WINDOW
THE SCOPE OF WORK
THE SCOPE
OF WORK
1/4" = 1'-0"2 PROPOSED FRONT ELEVATION
Scale
Date
5/24/2025 3:37:24 PM
1/4" = 1'-0"
A2.0
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PROPOSED FRONT &REAR EXTERIORELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1/4" = 1'-0"1 PROPOSED REAR ELEVATION
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR
18' - 4"
GROUND LEVEL
-1' - 10"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
THE SCOPE OF WORK
1.
2.
3.
4.
5.
6.
7.
8.
9.
ALL SILLS TO BE HISTORIC PROFILE: 2"+. EXTEND TO OUTSIDE OF CASING OR AS INDICATED ON DRAWINGS.
ALL MULLIONS TO BE 7/8" SIMULATED DIVIDED LIGHTS WITH SHADOW BARS.
ALL DOUBLE HUNG (CASEMENT AND AWNING TO HAVE FULL SCREENS) WITH HI TRANSPARENCY MESH.
PROVIDE CORRECT JAMB EXTENSIONS AS REQUIRED FOR WALL THICKNESS.
REFER TO EXTERIOR ELEVATIONS FOR MUNTIN LAYOUT.
EXTERIOR JAMB TRIM TO BE 5/4" X 5" OR AS INDICATED ON DRAWINGS.
ALL GLASS TO BE INSULATING, LOW E 368 WITH ARGON, TEMPER WHERE REQUIRED BY CODE.
MODEL NUMBERS AND ROUGH OPENINGS ARE FOR (MANUFACTURER/SERIES) UNLESS OTHERWISE NOTED. HEAD R.O. INDICATED ON SCHEDULE UNLESS NOTED OTHERWISE ON DRAWINGS. SUBSTITUTE WINDOWS TO MEET ENERGY CODE AND MATCH MANUFACTURER ATTRIBUTES.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECTURE REVIEW PRIOR TO ORDERING.
GENERAL WINDOW NOTES:
1.
2.
3.
4.
PROVIDE ALL NECESSARY STRUCTURAL BLOCKING AND RELATED WORK FOR DOOR, FRAME, AND HARDWARE INSTALLATION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
NO THROUGH-BOLTING WILL BE ACCEPTED. DOOR TO BE REINFORCED INTERNALLY.
ALL DOORS SHALL BE NEW WOOD FINISH DOORS. THICKNESS TO BE 1-3/4" EXCEPT WHERE NOTED.
MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECT REVIEW AND APPROVAL PRIOR TO ORDERING.
GENERAL DOOR NOTES:
EXISTING 1ST FLOOR0' - 0"
EXISTING 2ND FLOOR9' - 4"
EXISTING 3RD FLOOR
18' - 4"
GROUND LEVEL
-1' - 10"
EXISTING TOP OF
ROOF LEVEL29' - 8 7/8"
THE SCOPE OF WORK
1/4" = 1'-0"1 PROPOSED LEFT ELEVATION
Scale
Date
5/24/2025 3:37:30 PM
1/4" = 1'-0"
A2.1
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PROPOSED LEFT & RIGHTEXTERIOR ELEVATIONS
05/24/2025
22 Prescott St, Salem, MA 01970
1/4" = 1'-0"2 PROPOSED RIGHT ELEVATION
2 FRONT-LEFT PERSPECTIVE VIEW
1 REAR-RIGHT PERSPECTIVE VIEW
Scale
Date
5/24/2025 3:37:42 PM
A3.0
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PERSPECTIVE VIEWS
05/24/2025
22 Prescott St, Salem, MA 01970
Scale
Date
5/24/2025 3:37:56 PM
A3.1
EXISTING CONDITION
05/24/2025
PROP. NEW DORMERS& INT.RENOVATION
SCOPE: PROP. NEW DORMERS & INT. RENOVATION
PERSPECTIVE VIEWS 2
05/24/2025
22 Prescott St, Salem, MA 01970
1 FRONT-RIGHT PERSPECTIVE VIEW
2 REAR-LEFT PERSPECTIVE VIEW
APPLICATION FOR WAIVER OF THE DEMOLITION DELAY ORDINANCE
Pursuant to the Historic District's Act (M.G.L. Chapter 40C) and Salem Code 2-1572, application is hereby
made for issuance of a Waiver of the Demolition Delay Ordinance for demolition as described below.
Address of Property:
Name of Record Owner (s):
Owner Mailing Address:
Original Building Construction Date, if known:
Is the property listed on the National Register of Historic Places or contributing to a NR District?
Yes No Unknown
Description of Demolition Work Proposed:
Please attach any historical data and photographs, building plans, structural reports, or other pertinent information and
submit at least a week before the scheduled meeting. Applicants who omit this information or submit their application less
than a week before the meeting date should expect to attend additional meeting(s). A site visit of the property may be
requested.
Briefly describe the extent of the demolition:
Briefly describe the reason/justification for demolition:
Briefly describe any proposal for future construction/development:
Applications must include photos of existing conditions, taken from all public ways.
Name of Applicant: Owner Contractor Tenant Other:
Tel. #: E-mail Address:
Certificate will be mailed to the owner unless otherwise indicated here:
Certificate should be mailed to: Name
Mailing address: City: State: Zip:
22 Prescott Street Salem, MA 01970
ARSE1,O 'E/AROSA
1915
x
Demo of the existing roof and adding new dormers on both sides of the house.
Adding more sf to the 2nd dwelling unit since the residential needs in Salem is in demand.
Adimir Toska x
978-473-0699 adimirtoska@gmail.com
Adimir Toska
26 Beaver Park Danvers MA 01923
AddLnJ more sf to the 2nd dZellLnJ XnLt sLnce the resLdentLal needs Ln Salem Ls Ln demand
arsenLodlr#JmaLlcom