0003 BRADLEY ROAD, BPA-19-151 WEE
Boise Cascade Double 1-3/4" x 7-1/4" VERSA-LAM(g) 2.0 3100 SP PASSED
FB01 (Floor Beam)
BC CALCO Member Report Dry 11 span I No cant. February 11, 2019 10:06:54
Build 7082
Job name: 3 BRADLEY RD File name:
Address: 3 BRADLEY RD Description:
City, State, Zip: SALEM, MA Specifier:
Builder: CHARLIE GAMBALE Designer: TOM LYONS
Code reports: ESR-1040 Company: MOYNIHAN LUMBER N READING
—r
BI 10-00-00
132
Total Horizontal Product Length=10-00-00
Reaction Summary (Down / Uplift) (lbs)
Bearing Live Dead Snow Wind Roof Live
B1, 3-1/2" 837/0
B2, 3-1/2" 837/0
Load Summary Live Dead Snow Wind Roof Tributary
Live
Tag Description Load Type Ref. Start End Loc. 100% 90% 115% 160% 125%
0 Self-Weight Unf. Lin. (Ib/ft) L 00-00-00 10-00-00 Top 7 00-00-00
1 ATTIC W/SCUTTLE Unf.Area (Ib/ftZ) L 00-00-00 10-00-00 Top 10 16-00-00
HOLE
Controls Summary Value %Allowable Duration Case Location
Pos. Moment 1904 ft-lbs 25.3 % 90% 0 05-00-00
End Shear 687 lbs 15.8% 90% 0 00-10-12
Total Load Deflection L/816 (0.14") 29.4% n\a 0 05-00-00
Max Defl. 0.14" 14.0 % n\a 0 05-00-00
Span/Depth 15.8
%Allow %Allow
_Bearing Supports Dim (LxW) Value Support Member Material
61 Wall/Plate 3-1/2"x 3-1/2" 837 lbs n\a 9.1 % Unspecified
B2 Wall/Plate 3-1/2"x 3-1/2" 837 lbs n\a 9.1 % Unspecified
Notes
Design meets Code minimum (L/240)Total load deflection criteria.
Design meets arbitrary(1")Maximum Total load deflection criteria.
Calculations assume member is fully braced.
BC CALCO analysis is based on IBC 2018.
Design based on Dry Service Condition.
Install Screws with screw heads in the loaded ply.
Member has no side loads.
Connection Diagram: Full Length of Member
b -. d
a
C
e
Page 1 of 2
Boise Cascade Double 1-3/4" x 7-1/4" VERSA-LAM®2.0 3100 SP PASSED
FB01 (Floor Beam)
BC CALCO Member Report Dry 11 span I No cant. February 11, 2019 10:06:54
Build 7082
Job name: 3 BRADLEY RD File name:
Address: 3 BRADLEY RD Description:
City, State,Zip: SALEM, MA Specifier:
Builder: CHARLIE GAMBALE Designer: TOM LYONS
Code reports: ESR-1040 Company: MOYNIHAN LUMBER N READING
Connection Diagram: Full Length of Member
a minimum = 1-1/2" c=4-1/4"
b minimum =4" d =24"
e minimum = 1"
Install Screws with screw heads in the loaded ply.
Member has no side loads.
Connectors are: SDS 1/4 x 3-1/2
Disclosure
Use of the Boise Cascade Software is
subject to the terms of the End User
License Agreement(EULA).
Completeness and accuracy of input
must be reviewed and verified by a
qualified engineer or other appropriate
expert to assure its adequacy,prior to
anyone relying on such output as
evidence of suitability for a particular
application.The output here is based on
building code-accepted design
properties and analysis methods.
Installation of Boise Cascade
engineered wood products must be in
accordance with current Installation
Guide and applicable building codes.To
obtain Installation Guide or ask
questions,please call(800)232-0788
before installation.
BC CALCO,BC FRAMER@,AJSTM,
ALLJOIST@, BC RIM BOARDT.,BCI@,
BOISE GLULAMTM,BC FloorValue@,
VERSA-LAW,VERSA-RIM PLUS@,
Page 2 of 2