Loading...
CONFIRM. OF REQUESTED REVISIONS I'l Fri BOSTON. ,� MA6S- Jw tt LANG ASSOCIATES, ARCHITECTS 150 LINCOLN STREET BOSTON, MASSACHUSETTS 02111 617-423-5807 30 lune 1987 Mr. William H. Munroe Inspector of Buildings City of Salem One Salem Green Salem, Massachusetts 01970 Subject: Confirmation of Requested Revisions Cogswell Residences Renovations to No. 5 School Street, Salem, MA Dear Bill: This letter is in response to your request made during our telephone conversation yesterday regarding our recent submission covered by my earlier letter to you of 25 June 1987. Revisions to "Permit Set" You requested confirmation of the following revisions to be made to our drawings for the above-noted project: o Emergence Light and Exit Sign locations, previously agreed to in discussions with Captain Turner and annotated by electrician Kerry Conner on our prints on file, will also be depicted on our plans: o Self-closing Hinges will be called out on the schedule for all unit entry doors: o ;Mechanical Ventilation, per Code. will be required for all bathrooms: o Ducted Makeup Air will be provided to all utility closets for the mechanical equipment located therein: (Continued) Mr. William H. Munroe a0 ,lune 1987, Page Two o Ship s Ladders to the roof decks will be deleted and satisfactory alternate access will be provided; o Conventional Stairsteps will be provided beneath the roof skylights as as egressway, in lieu of the steeper ladder-like elements shown: o Acoustical Insulation, probably a layer of "Deciban" sheathing, will be added to Partition Type #5, for use on demising walls between units: o Fire Separation of unit demising walls will be confirmed to extend continuously from the basement slab to the roof sheathing in the attic: o Bedroom Skylights will be confirmed to be manually operable and shall have a 4 inch minimum curb (per Code Section 925.;.3); o Replacement Windows will be fitted with insulating glass and shall conform to the provisions of the Energy Code required for the project; o Trash Rooms shall be sprinklered; o Vent Stacks at Roof shall be either 2 feet high or 10 feet away from skylights; Supplemental Drawings Also per your request, we will forward one "Permit Set' of our drawings, reflecting the afforementioned revisions, as soon as they are completed. Subsequent Submission In addition, we understand that you will require a separate submission at a later date concerning the fire ratings of carpets to be utilized in the building. We will do so during early in the construction process, after carpeting is selected but before it is installed. (Continued) a Mr. William H. Munroe 30 ,June 1987, Page Three Conclusion Thank you.for your prompt and thorough review of our submission as well as for your w=illingness to issue the general building permit to my client upon receipt of this letter. We appreciate your responsiveness to the scheduling constraints of the project. Very truly yours, 0 loge P. Lang rin ipal LA ASSO AT , ARCHITECTS RPL,rl Encl. as noted XC: Jessica B. Herbert. Colin G. Simson, P.E. VIA MARATHON COURIER