342 Highland Ave Pre Construction Review PackageDesign Review Board Recommendation 342 Highland Avenue Pre-Construction Review of Entrance Corridor Project Meeting Date: August 27, 2025 Members Present: Paul Durand, Chair, Kate Martin, Catherine Miller, Elizabeth Murray, Marc Perras Members Absent: Leeann Leftwich, Sarah Tarbet At a regular meeting of the Design Review Board (DRB), upon a motion duly made and seconded, it was unanimously voted to recommend design approval to the City Planner of the pre-construction documents of the A.L. Prime gas/service station and associated site improvements. Referenced Plans and Documents 1.Document titled ‘Narrative and List of Plan Changes for DRB’ dated August 6, 2025. 2.Set of plans with red pen revisions titled ‘New Gas Station and C-Store A.L. Prime #161’, prepared by A.L. Prime Energy Consultant, Inc., 18 Lark Avenue, Saugus, MA 01906 and Derby Square Architects, 11 Derby Square STE 4, Salem, MA 01970, dated 7/18/24. Design Recommendations Overall, the DRB found that the proposed changes to the project are minimal and align with guidance from the Planning Board and MA DOT. The proposed changes also account for architectural revisions, which were conducted by Derby Square Architects. The Board recognized that the changes were captured in a clear and comprehensive way, with red markings on the revised plans, a narrative and list of changes, and a presentation of the revised plans side by side with the previously reviewed plans. Upon discussion and deliberation, the Board offers the following recommendations for the City Planner’s consideration: •Minimal Changes: The Board recognized that the proposed changes from their previous review are minimal and align with direction from the Planning Board and MA DOT. Additionally, the changes encompass refinements from an architect. •Architectural Revisions: The architectural revisions substituted previous plans and offer more detail. The substitutions are outlined in the narrative and list of plan changes. Signature of the DRB By the signature below, I certify that this recommendation accurately reflects the actions of the Design Review Board. __________________________________ Paul Durand 9-4-25 Date Chair NARRATIVE AND LIST OF PLAN CHANGES FOR DRB A.L. Prime Energy Proposed Convenience Store and Motor Fuel Facility 342 Highland Avenue, Salem, Massachusetts Salem Assessor Map 8 – Parcels 14 & 15 6 August 2025 This narrative and list of changes is submitted to the DRB for consideration in their determination of whether the plans submitted for permitting are consistent with the plans as previously approved by the DRB. A set of the plans submitted for permitting has been also submitted with red markup highlighting all of the specific plan revisions. This document provides a listing of those changes. All sheets in the permit set are commented on below. General – The general site layout, building footprint and elevations, driveway locations, grading, lighting, parking, and signage have not changed. New plan sheets have been added or substituted to provide architect and structural engineer stamped plans detailing the building and MA DOT plans required for the permitting of the abandoned utility disconnects and new driveway on Highland Avenue. C-0 Cover – - Updated the index to include new or substituted sheets. - Added an additional applicant contact - Made minor updates to the code summary per architect comments F1920 Existing Conditions Plan - (Eastern Land Survey) - No changes C-1.0 Proposed Site Layout – - Slight modifications to Highland Ave driveway per Planning Board and MA DOT comments - Added sidewalk along Barcelona as requested by Planning Board - Removed retaining wall along Highland Ave property line per request of Planning Board - Added notes per MA DOT permit approval - Added Highland Avenue bike lane and revised street pavement markings per recent MA DOT work A-1.0 Floor Plan - Substituted plan by Derby Square Architects Narrative and List of Changes for DRB Page | 2 A.L. Prime 342 Highland Avenue, Salem Massachusetts - No change to building footprint, doors, or windows A-2.1 Bldg Elevations - Plan by Derby Square Architects substituted for A-2.0 in DRB set - Raised top of fascia along 9” and top of parapet 4” - Added storefront detail and energy notes A-2.2 Bldg Elevations - Plan by Derby Square Architects substituted for A-2.1 in DRB set - Raised top of fascia along 9” and top of parapet 4” C-2 Grading - General site grading the same. Adjusted some spot grades per MA DOT comments and added some notes per MA DOT review comments - Changed catch basins at Highland Ave driveway to trench drains to better prevent runoff from reaching MA DOT drainage system - Increased infiltration area to include runoff from Barcelona and part of property across Barcelona per Planning Board peer review comments L-1 Landscape (KDTurner Design) - Added sidewalk along Barcelona and adjusted landscape areas - Added trees and landscape as requested by Planning Board - Removed retaining wall along Highland Ave prop line as requested by Planning Board SG-1 Sign and Graphics - Made price signage on canopy smaller as requested by Planning Board 7266-S1 Lighting Plan (RLA) - No change to photometrics, base plan updated to match changes to site plan such as sidewalk on Barcelona A2.3 Canopy Elevations - No changes other than to reduce size of price sign digits to match signage plan as requested by Planning Board Plans added into permit set, not in the original DRB set: - A1.1 – Life Safety - A-3.0 and A-3.1 Roof - A-4.0 Bldg sections - A-5.0 Ceiling - P-1.0 Plumbing Narrative and List of Changes for DRB Page | 3 A.L. Prime 342 Highland Avenue, Salem Massachusetts - S1 thru S6 Structural - C-1.1 Demo - C-3 Utilities - ER-1 Erosion Control - TK-1 and TK-2 UG Tank and Piping - SD-2 Site Details - C-2.1 ROW cross sections for MA DOT - DOT Plans – CC1/CC2/TMP1-3/UT-1 - FSP-1 and FSP-2 Fuel Island Fire Suppression - TR-1 Vehicle Swept Path - SW-1 Stormwater Areas 300 ' RAD I U S SITE 8-15 8-14 7-73 7-41 7-40 8-12 8-13 7-46 8-09 8-11 8-01 8-147 8-02 8-10 8-08 8-16 8-102 7-42 8-145 F O R E S T RIVER SCALE PROJECT ADDRESS SHEET VICINITY MAP APPROX SCALE DWG FILE COVER SHEET DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. REFERENCE - CITY OF SALEM GIS PROJECT A.L. PRIME ENERGY SAUGUS MA 01906 (781) 246-0201 18 LARK AVENUE CONSULTANT, INC. A.L. PRIME #161 SALEM, MASS 342 HIGHLAND AVENUE NEW GAS STATION and C-STORE APPLICANT CONTACT: BRIAN HUGHES -- MOBILE 781-929-2831 PROJECT INFORMATION SITE ADDRESS - 342 HIGHLAND AVE AND 2 BARCELONA AVE, SALEM, MA ASSESSOR MAP 8, PARCELS 14 & 15 OWNER - A.L. PRIME ENERGY CONSULTANT, INC., 18 LARK AVENUE, SAUGUS, MA 01906 APPLICANT - A.L. PRIME ENERGY CONSULTANT, INC., 18 LARK AVE, SAUGUS MA -BRIAN HUGHES, DIR OF CONST - 781-929-2831 -ANTHONY GUBA, ENGR - 512-745-6400 -NASSER ABU-EID, VP - 617-212-3551 EMERGENCY - 911 || DIGSAFE - 811 SALEM INSPECTIONAL SVCS AND BLDG DEPT - 978-619-5641 SALEM FIRE DEPT (NON EMERGENCY) - 978-744-1235 SALEM POLICE (BUSINESS) - 978-744-0171 SALEM PUBLIC SERVICES - 978-744-3302 SALEM WATER AND SEWER - 978-619-5674 SALEM HEALTH - 978-741-1800 ELECTRIC UTILITY - NATIONAL GRID GAS UTILITY - NATIONAL GRID CODES SUMMARY CODES: -MA STATE BUILDING CODE 780, 9TH EDITION BASED ON MODIFIED VERSION OF INTERNATIONAL CODES AS PUBLISHED BY INTL CODE COUNCIL (ICC): ---2015 IBC - INTL BUILDING CODE ---2021 IECC - INTL ENERGY CONSERVATION CODE ---2015 IMC - INTL MECHANICAL CODE ---2015 IFC - PORTIONS OF INTL FIRE CODE -MA STATE FIRE CODE 527 CMR 1.00 -MA ELECTRICAL CODE 527 CMR 12.00 (NFPA 70) -MA UNIFORM STATE PLUMBING CODE 248 CMR 10 -ARCHITECTURAL ACCESS BOARD REGULATIONS CMR 521 CMR -EPA GEN CONST PERMIT - DISTURBED AREA LESS THAN ONE ACRE. GC TO VERIFY THAT NPDES PERMIT IS NOT REQ'D PRIOR TO CONST OCCUPANCY - USE GROUP M MERCANTILE - CONVENIENCE STORE AND GAS STATION TOTAL GROSS AREA - ~3,353 GFA CONVENIENCE STORE CONSTRUCTION TYPE - IIIB - NON COMBUSTIBLE EXT WALLS, STEEL ROOF FRAMING/DECK HEIGHT - ~20'-2" (SINGLE STORY) EGRESS: -MAX EGRESS TRAVEL DISTANCE - 75 FT - SINGLE STORY -PROVIDED EGRESS WIDTH - (1ea) 72" AT FRONT CENTER, AND (1ea) 36" AT REAR -OCCUPANCY CALC - 40 EACH = (35ea) MERCANTILE + (5ea) STORAGE -NON SPRINKLER OCCUPANCY LESS THAN 50 WITH EGRESS PATH >75' REQUIRES SECONDARY EGRESS FIRE PROTECTION - NFPA 91: UNPROTECTED CONSTRUCTION. PROVISIONS MADE FOR SMOKE DETECTORS, EMERGENCY LIGHTING AND SIGNAGE, HORN AND STROBE ANNUNCIATORS AS SHOWN ON LIFE SAFETY SHEET. PLUMBING: -COMPLY WITH STATE PLUMBING AND FUEL GAS CODES (248 CMR) -MIN OF ONE ADA RESTROOM FOR MEN & ONE RESTROOM FOR WOMEN (per 248 CMR TABLE 1) -COMPLY WITH BOARD OF HEALTH REQUIREMENTS ENERGY: 2021 IECC TABLE C402.1.3, C402.1.4, and C402.4 FOR CLIMATE ZONE 5A WALLS - R 23 + R 3.8 ci ABOVE ROOF DECK - R30 c.i. UNHEATED SLAB - R 15 FOR 24" BELOW WINDOWS AND STOREFRONT - U .33 (Fixed) ENTRANCE DOOR - U .63 OPAQUE DOOR - U .37 PROJECT GENERAL SCOPE OF WORK THIS PROJECT PURPOSE IS TO CONSTRUCT A NEW CONVENIENCE STORE AND GAS STATION. THE WORK WILL INCLUDE: -DEMOLISH ALL EXISTING IMPROVEMENTS AT THE PROPERTY -INSTALL NEW STORMWATER STRUCTURES INCLUDING SUBSURFACE INFILTRATION -CONSTRUCT NEW ~3,353 SF CONVENIENCE STORE. -INSTALL ALL NEW UTILITIES -CONSTRUCT TWO NEW STEEL CANOPIES OVER FUELING AREAS -INSTALL UG MOTOR FUEL STORAGE TANKS AND ASSOCIATED UG PIPING TO INCLUDE DIESEL, FUEL DISPENSERS, ISLANDS, AND DRY CHEMICAL FIRE SUPPRESSION SYSTEM AT FUELING AREA -INSTALL ALL NEW CURBING, PAVING, ACCESS DRIVEWAYS AND SITE LANDSCAPE -THE BUSINESS IS PROPOSED TO OPERATE 24 HRS C-0AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 01 L E G E N D ANTHONY GUBA -- MOBILE 512-745-6400 24 M A Y 2 0 2 1 0 AG OR I G I N D A T E O F D R A W I N G 20 J U L 2 0 2 1 1 AG RE V P E R P L N G B D - R E D U C E P V M N T , A D D T R E E S , E T C . 23 A U G 2 0 2 1 2 AG AD D T R E E S A L O N G R E A R P L P E R D R B C M T S 02 S E P 2 0 2 1 3 AG RE V I S E D D R I V E W A Y P E R M A D O T C M T S 08 N O V 2 0 2 1 4 AG RE V P E R P E E R R E V I E W 03 D E C 2 0 2 1 5 AG RE V P E R P L N G B D C M T S 01 J U L 2 0 2 3 6 AG MI N O R R E V T O I N C L M A D O T A P P C U R B C U T L A Y O U T LAST REV COVER, LOCUS, CODE SUMMARY ORIG DATE DRAWING INDEX REV DATE C-0 PROPOSED SITE LAYOUTC-1.0 GRADING C-2 LIFE SAFETY PLAN, RESTROOM ADAA1.1 EXTERIOR ELEVATIONS 1 A2.0 ROOF PLANA3.0 TANK AND PIPING DETAILS EXSTG CONDITIONS (EASTERN LAND SURVEY ASSOC, INC)F19120 SELF SERVICE FIRE SUPPRESSION LANDSCAPE (KDTurner Design) EROSION CONTROL LIGHTING (RED LEONARD ASSOC) 05 APR 2021 L-1 ER-1 TK-2 FSP-1 SITE DETAILSSD-1 SITE DETAILSSD-2 NONE N/A BUILDING SECTIONSA4.0 NONE N/A EXTERIOR ELEVATIONS 2A2.1 UTILITIESC-3 TANK AND PIPING LAYOUT TK-1 5 24 MAR 2021 SELF SERVICE FIRE SUPPRESSIONFSP-2 STORMWATER AREASSW-1 7266-S1 17 MAR 2021 01 02 03 05 06 07 08 09 10 11 12 13 14 15 17 18 19 20 21 2 24 MAY 2021 24 MAY 2021 24 MAY 2021 24 MAY 2021 24 MAY 2021 24 MAY 2021 24 MAY 2021 24 MAY 2021 24 MAY 2021 THIS SET FOR BUILDING PERMIT APPLICATION 5 4 DEMOLITION PLANC-1.1 08 NOV 2021 7 4 24 MAR 2024 02 DEC 2021 3 6 1 18 NOV 2021 2 24 MAR 2024 24 MAR 2024 ARCHITECTURAL (DERBY SQUARE) STRUCTURAL (McBRIE) 22 24 SIGN AND GRAPHICSSG-1 25 37 FLOOR PLAN, FINISH & DOOR SCHEDULEA1.0 NONE N/A18 JUL 2024 REFLECTED CEILING PLANA5.0 16 23 26 GENERAL NOTES AND SPECIFICATIONS (McBRIE)N/ANONE 24 MAY 2021 2 24 MAR 2024 8 21 SEP 2024 ROOF DETAILSA3.1 27 PROGRAM OF STRUCTURAL TESTS & SPECIAL INSP (McBRIE) FOUNDATION PLAN AND DETAILS (McBRIE) CANOPY ELEVATIONS S1 S2 S3 23 JUL 2024 28 ROOF FRAMING PLAN & DETAILS (McBRIE)S4 29 DETAILS (McBRIE)S5 39 FRAMING ELEVATION & DETAILS (McBRIE)S6 CROSS SECTIONS AT R.O.W.C-2.1 23 MAR 2024 NONE N/A 04 24 M A R 2 0 2 4 7 AG RE V P E R M A D O T R E V I E W C M T s SITE MA DOT CURB CUT & TRAFFIC MGMNT (CHAPPELL) MISC CANOPY 30 38 40 VEHICLE SWEPT PATHS NONE N/A18 JUL 2024 NONE N/A18 JUL 2024 NONE N/A18 JUL 2024 NONE N/A18 JUL 2024 NONE N/A18 JUL 2024 NONE N/A18 JUL 2024 NONE N/A18 JUL 2024 21 S E P 2 0 2 4 8 AG AD D E D A R C H & S T R U C T U R A L S H T S N/ANONE23 JUL 2024 N/ANONE23 JUL 2024 N/ANONE23 JUL 2024 N/ANONE23 JUL 2024 N/ANONE23 JUL 2024 24 MAR 2024 24 MAR 2024 24 MAY 2021 4 24 MAR 2024 24 MAY 2021 4 24 MAR 2024 24 MAY 2021 4 24 MAR 2024 24 MAR 2024 24 MAR 2024 CC1 CC2 TMP1 CURB CUT PLAN DRIVEWAY GRADING AND PCR DETAILS TRAFFIC MANAGEMENT PLAN 11 APR 2024 1 23 APR 2024 11 APR 2024 1 23 APR 2024 23 APR 2024 NONE N/A 24 MAR 2024 24 MAY 2021 3 24 MAR 2024TR-1 A2.3 24 MAY 2021 1 02 SEP 2021 31 TMP2 TRAFFIC MANAGEMENT PLAN 23 APR 2024 NONE N/A 32 TMP3 TRAFFIC MANAGEMENT PLAN 23 APR 2024 NONE N/A 33 UT-1 UTILITY DISCONNECT PLANS 23 APR 2024 NONE N/A 34 36 35 11B PLUMBING SCHEMATICP1.0 NONE N/A29 OCT 2024 29 O C T 2 0 2 4 9 AG AD D E D P L U M B I N G S C H E M A T I C HIGHLAND AVENUE B A R C E L O N A A V E N U E UP UP UP UP UP UP UP 36+0 37+0 39+038+0 UP OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW 300 ' RAD I U S SITE 8-15 8-14 7-73 7-41 7-40 8-12 8-13 7-46 8-09 8-11 8-01 8-147 8-02 8-10 8-08 8-16 8-102 7-42 8-145 F O R E S T R I V E R LAYOUT OF PROPOSED SITE IMPROVEMENTS SEE GRAPHIC SCALE VICINITY MAP ZONE: B2 - BUSINESS HIGHWAY // ENTRANCE CORRIDOR OVERLAY DISTRICT PROPOSED MAX. BLDG. HEIGHT (FT) MIN. LOT AREA (FT) MIN. LOT FRONTAGE (FT) MIN REAR YARD DEPTH (FT) MIN FRONT YARD DEPTH (FT) 10 FT (min) REQUIRED EXISTING PARKING SPACES (MIN 9.0'x19' / 170SF) ZONING INFO - MAP 8, PARCELS 14 & 15 - 342 HIGHLAND AVE & 2 BARCELONA AVE *40 FT (min) 46,263 SF± MIN SIDE YARD DEPTH (FT) 25 % --- *20,000 SF 100 FT *200 FT NO CHANGE NO CHANGE RELIEF RQSTD NONE NONE NONE NONE NONE NONE NONE PROPOSED USES: MOTOR VEHICLE LIGHT SERVICE - PERMITTED RETAIL STORE - PERMITTED REFERENCE: ZONING ORDINANCE - CITY OF SALEM ADOPTED SEPT 10, 2009 W/ AMENDMENTS THRU JULY 9, 2020 (SUPP NO. 23, UPDATE 3) -Retail - 1ea / 150 GFA (less storage) =2,074sf / 150 = 13.82 15.7% GENERAL NOTES 1.THE GENERAL PURPOSE OF THIS WORK IS TO REMOVE EXSTG IMPROVEMENTS AND CONSTRUCT A NEW GAS STATION WITH 12 FUELING POSITIONS AND A 3353 SF CONV STORE 2.THE PROSPECTIVE PROPERTY OWNER WILL OBTAIN ANY APPLICABLE BOARD AND STATE APPROVALS AND GENERAL BLDG PERMIT. THE CONTRACTOR WILL BE RESPONSIBLE FOR PERMITS FROM THE LOCAL FIRE MARSHAL'S OFFICE AND TRADE OR BLDG PERMITS FROM THE LOCAL BLDG DEPT AND ALL ASSOCIATED TESTING AND INSPECTION REQUIREMENTS. 3.THE CONTRACTOR SHALL CONTACT DIG-SAFE PRIOR TO ANY CONST EXCAVATION (811) 4.PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL FIELD VERIFY: 4.1.PROPERTY BOUNDARIES, EASEMENTS, AND RIGHT OF WAYS. 4.2.EXSTG STRUCTURES, BUILDINGS, AND DRIVEWAYS 4.3.LOCATIONS, SIZES, DEPTHS OF EXSTG UG UTILITIES, PIPING, STRUCTURES, TANKS, ETC. 4.4.ALL EXSTG AND PROPOSED CRITICAL ELEVATIONS 4.5.CCTV OF MUNICIPAL SEWER LINES FOR CONDITION, INVERT, AND LOCATION. 5.WHERE CONFLICTS ARISE BETWEEN FIELD CONDITIONS & PROPOSED CONST, OR IF THERE IS A CONFLICT BETWEEN ANY REGS OR MUNICIPAL REQMNTS AND PROPOSED PLANS, CONTRACTOR SHALL NOTIFY OWNER'S REP PRIOR TO CONTINUANCE OF WORK. 6.PROPOSED WORK INCLUDES: 6.1.PREP SITE PER ANY CONDITIONS OF SITE APPROVALS FROM ZONING, PLANNING, CONSERVATION COMMISSION, MA STATE HIGHWAY, OR ANY OTHER APPLICABLE BODY 6.2.RAZE AND REMOVE ALL EXISTING IMPROVEMENTS 6.3.REPLACE UG UTILITIES AND INSTALL ANY STORMWATER MANAGEMENT STRUCTURES 6.4.INSTALL NEW UNDERGROUND STORAGE TANKS 6.5.CONSTRUCT NEW STORE, GAS STATION ISLANDS & CANOPIES 6.6.INSTALL PAVEMENT & CURBING INCLUDING DRIVEWAYS. MATCH GRADE ALONG ALL PROP LINES 6.7.INSTALL SIGNAGE IAW SIGNAGE APPROVALS 6.8.INSTALL LANDSCAPING, FENCING AND SCREENING PER APPROVED SITE PLAN. 7.THIS PROJECT IS NOT EXPECTED TO REQUIRE ANY BLASTING, DEWATERING, OR TEMPORARY USE OF WATER. SHOULD DEWATERING BE REQUIRED, IT WILL ONLY BE DONE WITH PROPER PERMITTING AND IAW ALL MA DEP REGULATIONS, UNDER THE SUPERVISION OF A MA LSP. 14 NONE REFERENCE - SALEM GIS MAX LOT COVERAGE, BLDGS (%) 30 FT (min)NONE 14 >30 FT 245 FT± 42.4% SCALE PROJECT ADDRESS SHEETDWG FILE LAYOUT A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. PROPOSED SITE C-1.0AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 DE S C R I P T I O N RE V BY DA T E 24 M A Y 2 0 2 1 0 AG OR I G I N D A T E O F D R A W I N G REFERENCE: PROPERTY LINES AND OTHER EXISTING SITE IMPROVEMENT INFORMATION ON THIS DRAWING TAKEN FROM EXISTING CONDITIONS PLAN BY EASTERN LAND SURVEY, ASSOC, INC., SHEET F 19120, 05 APRIL 2021, SCALE 1"=20'. ALL SITE IMPROVEMENTS ARE SHOWN PER THE BEST AVAIL INFO AND MUST BE VERIFIED IN THE FIELD, PARTICULARLY PRIOR TO ANY EXCAVATION OR WORK THAT MAY AFFECT BURIED UTILITIES. 03 MIN. LOT WIDTH (FT) MIN OPEN SPACE (%) MAX. BLDG. HEIGHT (STORIES) BUFFER AREA RQD FROM RESIDENTIAL FLOOR AREA RATIO 30 FT NONE ---NONE1 NONE ---NONE7.2% NO CHANGE 243.5 FT± 22 FT± --- n/a --- 0 % 40 FT 30 FT * MODIFIED PER SECTION 6.3.2 MOTOR VEHICLE LIGHT SERVICE STATION --- n/a n/a n/a n/a n/a n/a n/a 3/25/24 20 J U L 2 0 2 1 1 AG RE V P E R P L N G B D C M T S - R E D U C E D P V M N T , A D D E D T R E E S , E T C 22 J U L 2 0 2 1 2 AG AD D E D F U T U R E E V C H A R G I N G L O C A T I O N 02 S E P 2 0 2 1 3 AG AD D E D L A N D S C A P E P E R D R B C M T S , A D J D R I V E W A Y P E R D O T C M T S L E G E N D 08 N O V 2 0 2 1 4 AG RE V P E R P E E R R E V I E W 30 N O V 2 0 2 1 5 AG RE V P E R P L N G B D & P E E R R E V I E W C M T S CITY RQMNTS PRIOR TO BLDG PERMIT APPLICATION 1.APPLICANT TO FILE DRAINAGE ALTERATION PERMIT (LETTER) PREPARED BY PROFESSIONAL ENGINEER LICENSED IN MA, AND CORRESPONDING FEE. 2.CITY SEWER LINE TO BE INSPECTED BY CCTV 3.CITY UTILITY RECORDS TO BE INVESTIGATED AND ALL PRIOR WATER AND SEWER SERVICES TO BE PROPERLY ABANDONED AT THE CITY MAIN. 4.APPLICANT TO PROVIDE BACKUP DATA AND ENGINEERING STATEMENT CONFIRMING CITY WATER MAIN HAS ADEQUATE FLOW AND PRESSURE FOR PROPOSED PEAK DEMAND. 5.APPLICANT TO PROVIDE PROPOSED CONNECTION DETAILS FOR WATER AND SEWER SERVICES FOR CITY ENGRG DEPT APPROVAL, INCLUDING DETAILS FOR WATER METER AND BACKFLOW PREVENTION DEVICES. 6.APPLICANT TO VERIFY EXISTING AND PROPOSED UTILITY CROSSING ELEVATIONS AND DEMONSTRATE TO THE SATISFACTION OF THE CITY ENGRG DEPT THAT ADEQUATE SEPARATION OR OTHER MEANS OF PROTECTION WILL BE PROVIDED. 7.NO DEWATERING WILL BE CONDUCTED WITHOUT ALL REQUIRED PRIOR APPROVALS FROM CITY, MA DEP, AND EPA, AND DESIGN, PERMITTING, AND OVERSIGHT BY MA LSP. 01 J U L 2 0 2 3 6 AG RE V P E R M A D O T A P P C U R B C U T L A Y O U T 24 M A R 2 0 2 4 7 AG RE V P E R M A D O T C M T S OPEN CASE METAL PRODUCT SHELVING METAL PRODUCT SHELVING AT T E N D A N T CO U N T E R SINGLE STORY MASONRY 3,353 GFA (1,112 SF STORAGE) EL E C T R I C A L IT C A B I N E T COFFEE BAR METAL PRODUCT SHELVING METAL PRODUCT SHELVING DESK ICE 100 102 107 104 106 105 103 101 DISPLAY COOLER & FREEZER DOORS BY OTHERS -TYP. HAND SINK MOP SINK 3 BAY SINK SALES AREA ATTENDANT AREA NON-SALES AREA(MECHANICAL, STORAGE, OFFICE, RESTROOMS, HALLWAY1,279 SF+/- 1 A4.0 1 A4.0 STEEL BEAM 2 A4.0 2 A4.0 BLOCK-OUT FOR COLUMN EXTERIOR WALL 6"x6"+/-STL COL. WRAPPED IN BLK.&INSUL'N W/INSIDE OF COL. FLUSH W/INSIDE FACE OF BLK FASCIA ABOVE TO BE SET 1"(MIN) PROUD OF COL.BLOCK. INTERIOR INSUL'N/ SHEATHING/FRAMING AROUND COLUMN.ALIGN 4 5 .0 0 ° 1'-4" 1'-1 1/4" 0' - 6" 0' - 11" 0' - 7 1/4" 0' - 8 1/2" 0' - 9 3/4" 0'-0" = TOTAL HEIGHT CHANGE FOR STRUCTURAL BEARING FROM BACK TO FRONT OF BUILDING- SEE ALSO STRUCTURAL DWGS. TRANSACTION DRAWER 0' - 4 3/4" 0' - 3 1/2" 0' - 2 1/4" ! !" ! BB 1 5 2 3 4 6 AA #$ T.O.W. STEPS DN TO 1'-0 3/8" 0' - 1" ELEV ABOVE T.O. BLOCK @ 0'-0" (REAR OF BUILDING) % $ % % DOOR HARDWARE 1. LEVER HARDWARE PASSAGE SET, 4 SETS OF HINGES, SILENCERS, WALL STOP. 2. LEVER HARDWARE PRIVACY SET, CLOSER, 4 SETS OF HINGES, SILENCERS, WALL STOP. 3. KEYED OFFICE LOCKSET- 4 SETS OF HINGES, SILENCERS WALL STOP. 4. COOLER OR FREEZER DOOR HARDWARE AS REQUIRED LABEL 100 101 102 103 104 105 106 107 6'-0" x 7'-0" * REFER TO FRONT ELEVATION AND FLOOR PLAN FOR STOREFRONT GLASS AND ENTRY SIZES USE 2"X4 1/2" FINISHED BLUE ALUMINUM FRAME WITH THERMAL BREAK. ! ! ! ! REMARKSWIDTH/HEIGHT THICKNESS DOOR TYPE FRAME MATERIAL HARDWARE GROUP 3'-0" x 7'-0" 3'-6" x 7'-0" 3'-0" x 7'-0" 3'-0" x 7'-0" 3'-0" x 7'-0" 3'-0" x 7'-0" 3'-0" x 7'-0" 2" 2" 1 3/4" 1 3/4" 1 3/4" 1 3/4" IM GLASS SOLID WOOD HM ALUMINUM HM HM HM HM HM HM HM PRIVACY/CLOSER GLASS DOOR INSULATED GALV DOOR BY WALK IN MANUFACTURE PRIVACY/CLOSER 2 2 4 4 2" STOREFRONT ENTRY DOOR REAR EXIT DOOR SOLID WOOD SOLID WOOD GLASS KEYED OFFICE LOCKSET INSULATED GALV DOOR BY WALK IN MANUFACTURE 3 2 IM ROOM MAIN SALES AREA RESTROOMS OFFICE MECHANICAL/STORAGE WALK-IN COOLER WALK-IN FREEZER CERAMIC TILE " ! ! " ! ! " ! ! " ! ! REMARKSFLOORBASEWALLCEILING VINYL COVE SLAT DISPLAY WALL BEHIND COUNTER CERAMIC TILE CERAMIC TILE CERAMIC TILE CERAMIC TILE MFGR INSULATED FLOOR CERAMIC TILE CERAMIC TILE CERAMIC TILE VINYL COVE VINYL COVE MFGR INSULATED WALL MFGR INSULATED WALL MFGR INSULATED PANEL PAINTED GYPSUM CERAMIC TILE PAINTED GYPSUM PAINTED GYPSUM MFGR INSULATED PANEL EXPOSED STEEL FRAMING EXPOSED STEEL FRAMING 2x2 SUSPENDED CEILING EXPOSED STEEL FRAMING Scale: Project #: Date :Drawn by: Checked by: As indicated 7/ 1 8 / 2 0 2 4 3 : 4 8 : 0 2 P M A1.0 Fl o o r P l a n , F i n i s h & D o o r S c h e d u l e 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 1/4" = 1'-0"1 FLOOR PLAN No . D a t e De s c r i p t i o n 04 TOTAL TRAVEL DISTANCE TO THE NEAREST EXIT = 68'-0" ALLOWED 75'-0" HFE SC S PS ATTENDANT PULL STATION S SALES AREA WEATHERPROOF EXTERNAL FIRE ALARM/STROBE RR RR S RR FACP FARA PS RR RR MOUNTED AT JOISTS ABOVE AND OUTSIDE OF COOLER BOX HH NOTE: DO NOT LOCATE SMOKE DETECTOR WITHIN 4'-0" OF HVAC SUPPLY REGISTER RR LEGEND FOR THE DEVICES SYMBOLS: AL -SHALL BE CONNECTED TO FACP TO SET OFF ALARM DET-DETECTION DEVICES WIRED TO FACP TO ACTIVATE ALL ALARM DEVICESALAL AL AL AL AL AL AL AL AL AL AL AL DET DET DET DET DET DET DET DET DET DET DET DET AL SC DET AL FARA FARA FARA FARA BB 1 5 2 3 4 6 A MOUNTED INSIDE COOLER BOX RRDET LIFE SAFETY LEGEND ILLUMINATED EXIT SIGN ILLUMINATED EXIT SIGN W/ EMERGENCY LIGHTS EMERGENCY LIGHTS DOUBLE EMERGENCY LIGHTS SINGLE H HORN STROBE ALARM WALL MOUNTED FIRE EXTINGUISHER (MAY BE IN CABINET 1EA) PS PULL STATION SMOKE & CARBON MONOXIDE DETECTOR SMOKE DETECTOR ENTRANCE / EXIT S SC FE MEANS OF EGRESS STROBE ALARM ONLY EXIT SIGN WITH DIRECTION ARROW FIRE ALARM CONTROL PANEL (1EA)FACP FIRE ALARM REMOTE ANNUNCIATOR (3 EA)FARA COMBINATION RATE OF RISE DETECTOR AND 135 DEGREE FIXED TEMP (4EA) RR DI S P E N S E R H T . INSULATE HOT PIPES AND COVER ALL PROTRUDING OBJECTS HC WALL SINK TOTO:LT 307 OR OF EQUAL DIMENSIONS FAUCET; HC ACCESSIBLE, SELECT TO FIT LAV STANDARD TP 1. "HC" DENOTES HANDICAPPED ACCESSIBLE FIXTURES PER ADA AND MASS BARRIERS BOARD REGS. 2. G.C. TO PROVIDE ADEQUATE BLOCKING TO SUPPORT ALL SUPPLIED TOILET ROOM ACCESSORIES, AND TO COORDINATE WITH PLUMBER INSTALLATION OF FIXTURE CHAIRS AND SUPPORTS FOR WALL MOUNTED FIXTURES 3. REFER TO FINISH SCHEDULE FOR FINISHES NOT NOTED ON THIS DRAWING. 4. PROVIDE TILE BACKER BOARD (5/8" GP "DENS-SHIELD" OR EQUAL) BEHIND ALL TILED SURFACES 5. PROVIDE ACCESSIBLE FIXTURES BY "TOTO" OR EQUAL. 6"3' - 6" 2' - 9 " HC 1' - 6 " 1' - 6" 1' - 4 " HC 3' - 6 " M A X MI R R O R 4' - 0 " 3' - 2 " MA X . 2' - 1 0 " MA X 5" SIDE TYP. 3' - 6" 1' - 0" 3' - 4" MI N . 1 1 / 2 " MI N . 1' - 3 " HC Scale: Project #: Date :Drawn by: Checked by: As indicated 7/ 1 8 / 2 0 2 4 3 : 4 8 : 0 3 P M A1.1 Li f e S a f e t y P l a n 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 1/4" = 1'-0"1 LIFE SAFETY PLAN 1/2" = 1'-0"2 ACCESSIBILITY FIXTURE MOUNTING HEIGHTS/ LOCATIONS 1/2" = 1'-0"3 SINK ELEVATION 1/2" = 1'-0"4 TOILET ELEVATION No . D a t e De s c r i p t i o n 05 EnergyEnergy First Floor- T.O.SLAB 100' -0" RR CEILING 110' -0" T.O. STEEL PLATE (FRONT) 114' -1" T.O.FASCIA 115' -6" % % $ ! & % ' $ ! % & $ ' +/- B A First Floor- T.O.SLAB 100' -0" T.O.PARAPET 120' -6" T.O.FASCIA 115' -6" % $ 342 B.O.F. 94' -4" () * SIGNAGE PER SPECS. AS APPROVED BY SEPARATE SIGN PERMIT ! $ ! ATM A A B A C 1 5234 6 & ' & ' + B TEMPERED GLASS 8' - 0 " A 1'-8"6'-0"1'-8" C 2"1'-4"2"3'-0"3'-0"2"1'-4"2" BLUE ALUMINUM FRAME 2"3'-6"2"3'-6"2" 3 7 / 8 " 7' - 6 1 / 8 " 2" 7'-6" 3' - 8 " 2" 4' - 2 " 3 7 / 8 " BLUE ALUMINUM FRAME 2"3'-6"2"3'-6"2" 3 7 / 8 " 7' - 6 1 / 8 " 2" 7'-6" 3' - 8 " 2" 4' - 2 " % ENERGY –2021 IECC TABLE C402.1.3 AND C402.1.4 AND C402.4 FOR CLIMATE ZONE 5A REQUIRED PROVIDED REFERENCE Wood Framed walls- R 20 + R 3.8 ci R 23 + R 3.8 ci Detail 3-A3.1 Insulation above roof deck - R 30 ci R 30 ci Detail 3-A3.1 Unheated slabs - R 15 for 24" below R 15 for 24" below Detail 3-A3.1 Windows and Storefront- U .36 (fixed) U .33 (fixed) Detail 1-A2.0 Entrance Door - U .63 U .63 Detail 1-A2.0 Opaque Door - U .37 U .37 Detail 2-A2.1 Scale: Project #: Date :Drawn by: Checked by: As indicated 7/ 1 8 / 2 0 2 4 3 : 4 8 : 0 4 P M A2.0 Ex t e r i o r E l e v a t i o n s 1 , S t o r e F r o n t , Wa l l D e t a i l 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 1/4" = 1'-0"2 EAST ELEVATION 1/4" = 1'-0"1 SOUTH ELEVATION (FRONT) 1/4" = 1'-0"3 STORE FRONT No . D a t e De s c r i p t i o n % % $ ) , $ ! + & ' - )( % ) 06 First Floor- T.O.SLAB 100' -0" T.O. STEEL PLATE (FRONT) 114' -1" T.O.PARAPET 120' -6" T.O.FASCIA 115' -6" % $ ! & % ' & % ' LOW TOP OF PLATE 112' -9" BEND IN WALL -SEE PLAN BEND IN WALL -SEE PLAN , $ ! $ ! $ ! First Floor- T.O.SLAB 100' -0" T.O.FASCIA 115' -6" % $ ! & % ' LOW TOP OF PLATE 112' -9" 12 ) . First Floor- T.O.SLAB 100' -0" T.O. STEEL PLATE (FRONT) 114' -1" T.O.PARAPET 120' -6" T.O.FASCIA 115' -6" WALL LIGHT FIXTURE $ ! % PITCH TOP OF METAL FASCIA AROUND ENTIRE BLDG PERIMETER 1/8" PER FOOT TOWARDS ROOF % & % ' & % ' B A Scale: Project #: Date :Drawn by: Checked by: 1/4" = 1'-0"7/ 1 8 / 2 0 2 4 3 : 4 8 : 0 5 P M A2.1 Ex t e r i o r E l e v a t i o n s 2 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 1/4" = 1'-0"1 NORTHEAST ELEVATION 1/4" = 1'-0"2 NORTH ELEVATION (REAR) 1/4" = 1'-0"3 WEST ELEVATION No . D a t e De s c r i p t i o n 07 / 1/4"/FT RTU-2 RTU-4 RTU-3 RTU-5 RTU-7 RTU-6 RTU-1 RTU-2 RTU-4 RTU-3 RTU-5 RTU-7 RTU-6 & ' % % % , $ !! - # % 1/4"/FT DOWNSPOUTS TO UG STORMWATER PIPING PER SITE PLAN ALUMINUM GUTTER FULL WIDTH OF ROOF TYP. B 1 5 2 3 4 6 A 5 A3.1 Sim Scale: Project #: Date :Drawn by: Checked by: 1/4" = 1'-0"7/ 1 8 / 2 0 2 4 3 : 4 8 : 0 5 P M A3.0 Ro o f P l a n 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 1/4" = 1'-0"1 Roof Plan No . D a t e De s c r i p t i o n 08 , $ ! % ( ) % ) ! % +! & , 00' & / % ) ' ( ) % , % ! ! ! - ) - + ( 1 ! & , 00' & ' $ ! * 1 ! & , 00' % 1 ! & , 00' % ! &.+ 00' & 2 ' ( & ) ' ( & 2,' # % , $ ! % ! !" ! * T.O.BOND BEAM 3 ( ! % % % ! " % % # # % , $ ! % $ ! / +! & , 00' & % ) ' ) ) % % ) 1 +! 1 +! & (+! 1 ' CENTER FRONT !" ! 4560 7$ 8 9 " : ! # $ ! - # % % % % % % T.O.BOND BEAM 3 ( ! # ! !" ! % , $ ! % METAL BRACING AS REQUIRED LEFT AND RIGHT FRONT (2'0" AT SIDES) $ ! 1 T.O.BOND BEAM 3 ( ! % % $ ! 1 !" ! 4560 7$ 8 9 " :; ! # # & ' # & ' # % % T.O.BOND BEAM 3 ( ! * % # % , $ ! % % % # & % # % ' ! ! !"+! 1 - !" ! !"+! 1 - $ ! ! <= $ ! ,! , ! $ ! % & ' Scale: Project #: Date :Drawn by: Checked by: As indicated 7/ 1 8 / 2 0 2 4 3 : 4 8 : 0 6 P M A3.1 RO O F D E T A I L S 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 6" = 1'-0"2 HVAC CURB DETAIL 1 1/2" = 1'-0"1 ROOF AT PARAPET 1 1/2" = 1'-0"5 ROOF AT PARAPET @SIDE WALL- VARIES WITH DISTANCE 1 1/2" = 1'-0"4 TOP OF ANGLE SIDE WALL ( LOOKING AWAY FROM THE STORE FRONT) 1 1/2" = 1'-0"3 WALL DETAIL- STUD WALL AGAINST CONCRETE WALL No . D a t e De s c r i p t i o n 09 First Floor- T.O.SLAB 100' -0" T.O. STEEL PLATE (FRONT) 114' -1" T.O.FASCIA 115' -6" B.O.F. 94' -4" +/- 1 5 ! ! ! " # $ ! % # $ # ! & ' First Floor- T.O.SLAB 100' -0" RR CEILING 110' -0" T.O. STEEL PLATE (FRONT) 114' -1"T.O. STEEL PLATE (FRONT) 114' -1" T.O.FASCIA 115' -6" B.O.F. 94' -4" 2" RIGID XPS INSULATION ( LOW TOP OF PLATE 112' -9" BA T.O.BOND BEAM ) % ( T.O.BOND BEAM " # " $ & ' ( * ! "+ ( " " $ # # ,- $ " ."( # ! & ' . ,( ,( # . # . Scale: Project #: Date :Drawn by: Checked by: As indicated 7/ 1 8 / 2 0 2 4 4 : 2 8 : 4 4 P M A4.0 Bu i l d i n g S e c t i o n s 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 1/4" = 1'-0"1 BUILDING SECTION EAST-WEST (LOOKING NORTH) 1/4" = 1'-0"2 BUILDING SECTION NORTH-SOUTH ( LOOKING WEST) No . D a t e De s c r i p t i o n 1 1/2" = 1'-0"3 BUILDING SECTION @ STOREFRONT 10 EXPOSED EXPOSED LI G H T I N G B Y C O O L E R S U P P L I E R G.W.B. CEILING 8'-0" A.F.F. G.W.B. CEILING 8'-0" A.F.F. RTU-1 RTU-2 EXPOSED STORAGE MECHANICAL/ STORAGE RESTROOM RESTROOM MECHANICAL/ STORAGE AT T E N D A N T CO U N T E R RTU-4 NOTE: HVAC RTU #1-3 675 # REFRIG RTU # 4-7 500# KNOX BOX PER FD REQS LIGHTING BY COOLER SUPPLIER INSULATED METAL PANEL COOLER -WALLS & CEILING IN S U L A T E D M E T A L P A N E L CO O L E R - WA L L S & C E I L I N G SALES AREA ATTENDANT AREA RTU-5 RTU-7 RTU-6 RTU-3 BB 1 1 5 2 3 4 6 AA * . , 3 - 3 - . , , & ' LIGHTING TRACK WITH FIXTURES BATTERY PACK WITH HEADS OUTDOOR CEILING LIGHTS WALL MOUNTED CEILING OR PENDANT LED REFLECTED CEILING LEGEND WALL PACK LIGHT GYPSUM DRYWALL CEILING 2X2 ACOUSTIC CEILING TILE LINEAR METAL PANEL CEILING SUPPLY DIFFUSERS CEILING RETURN GRILLE/REGISTER CEILING EXHAUST GRILLE/REGISTER ROUND SUPPLY DIFFUSERS LED SUSPENDED FIXTURE BY COLUMBIA LAW LED WRAPAROUND -4"ML 48 WATS 5" RECESSED LED LED LIGHTING FIXTURE HIGH BAY BY LUMEGEN Scale: Project #: Date :Drawn by: Checked by: As indicated 7/ 1 8 / 2 0 2 4 3 : 4 8 : 0 8 P M A5.0 Re f l e c t e d C e i l i n g P l a n 21021ALSA Ga s S t a t i o n / C o n v e n i e n c e S t o r e A. L . P R I M E E N E R G Y 7/18/24 KT RG 34 2 H I G H L A N D A V E , S A L E M , M A 0 1 9 7 0 No . D a t e De s c r i p t i o n 11 D01 FLOOR PLAN SEE GRAPHIC SCALE GENERAL NOTES 1.THIS PLAN IS ONLY INTENDED TO SHOW SCHEMATIC WATER AND SANITARY PLUMBING LAYOUT WITHIN THE BUILDING AND SHOULD NOT BE USED FOR ANY OTHER PURPOSE. REFER TO DERBY SQUARE ARCHITECTURAL PLANS AND McBRIE STRUCTURAL PLANS FOR ALL OTHER BUILDING LAYOUT AND CONSTRUCTION DETAIL INFORMATION. 2.ALL WORK TO BE DONE IAW ALL CITY OF SALEM ENGINEERING REQUIREMENTS AND CONDITIONS. PLUMBING CONTRACTOR TO CONFIRM WATER METER TYPE AND LOCATION WITH CITY OF SALEM PRIOR TO INSTALLATION. 3.SANITARY VENT STACKS LOCATIONS ARE SUGGESTED BUT LICENSED PLUMBER MAY RELOCATE AND ADD AS REQUIRED TO MEET ALL PLUMBING CODES. 4.ALL WOOD IN CONTACT WITH MASONRY OR CONCRETE SHALL BE PRESSURE TREATED. 5.PROVIDE SOLID WOOD BLOCKING BEHIND ALL WALL MOUNT FIXTURES. 6.TRADE CONTRACTORS SHALL SUBMIT SHOP DRAWINGS AND/OR EQUIPMENT CUT SHEETS AND SPECS PRIOR TO PROCEEDING WITH PURCHASE OF MATERIALS OR FABRICATION. SCALE PROJECT ADDRESS SHEETDWG FILE DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. PLUMBING P-1.0AS NOTED SALEM, MA 342 HIGHLAND AVENUE TBD-021-01 SALEM A.L. PRIME SITE # tbd 29 O C T 2 0 2 4 0 AG OR I G I N D A T E O F D R A W I N G 11B WATER AND SANITARY FLOW ESTIMATES 1.WATER AND SEWER FLOWS ARE EQUAL. NO IRRIGATION OR FIRE PROTECTION DEMAND. IF ANY IRRIGATION IS INSTALLED, IT WILL UTILIZE A SEPARATE ON SITE IRRIGATION WELL THAT WILL NOT BE CONNECTED TO THE DOMESTIC SERVICE IN ANY WAY. 2.MAXIMUM DAILY USAGE OF 500gpd (WATER & SEWER) BASED ON MA TITLE V AND SIMILAR STATION EXPERIENCE THAT IS LESS THAN TITLE V RATES: (1) RETAIL STORE MINIMUM OF 200gpd PLUS (2) MOTOR FUEL STATION MINIMUM OF 300gpd EQUALS 500gpd 3.52gpm PEAK FLOW RATE BASED ON SIMULTANEOUS OPERATION OF INSTALLED FIXTURES: (TWO RESTROOMS PLUS THREE SINKS PLUS ONE HOSE BIB). THIS RATE MAY BE LIMITED BY THE 1" SERVICE MAIN BUT ANY LIMITATION IS ACCEPTABLE FOR THE USE AT THIS LOCATION. WATER USE EXPERIENCE AT SIMILAR LOCATIONS INDICATE THAT THE 1" SERVICE PROVIDES ADEQUATE SUPPLY. SCHEMATIC St r u c t u r a l D e s i g n & S a l e s Mc B r i e , LL C  12 St r u c t u r a l D e s i g n & S a l e s Mc B r i e , LL C  13 St r u c t u r a l D e s i g n & S a l e s Mc B r i e , LL C  14 St r u c t u r a l D e s i g n & S a l e s Mc B r i e , LL C  15 St r u c t u r a l D e s i g n & S a l e s Mc B r i e , LL C  16 St r u c t u r a l D e s i g n & S a l e s Mc B r i e , LL C  17 36+0 37+0 39+038+0 HIGHLAND AVENUE B A R C E L O N A A V E N U E UP UP UP UP UP UP UP 8" R C P S E W E R UP SMH SMH 6" C . I . W A T E R 12" RCP SEWER 16" WATER GENERAL NOTES 1. THE GENERAL PURPOSE OF THIS WORK IS TO REMOVE EXSTG IMPROVEMENTS IN PREPARATION FOR THE CONSTRUCTION OF A NEW GAS STATION AND CONV STORE 2. THE PROSPECTIVE PROPERTY OWNER WILL OBTAIN ANY APPLICABLE BOARD AND STATE APPROVALS AND GENERAL BLDG PERMIT. THE CONTRACTOR WILL BE RESPONSIBLE FOR PERMITS FROM THE LOCAL FIRE MARSHAL'S OFFICE AND TRADE OR BLDG PERMITS FROM THE LOCAL BLDG DEPT AND ALL ASSOCIATED TESTING AND INSPECTION REQUIREMENTS. 3. THE CONTRACTOR WILL OBTAIN DEMOLITION PERMIT PRIOR TO ANY WORK ON SITE, INCLUDING VERIFYING UTILITY SHUTOFFS OR DISCONNECTS, AND ANY OTHER CITY OF SALEM REQUIREMENTS FOR DEMO PERMIT. 4. THE CONTRACTOR SHALL CONTACT DIG-SAFE PRIOR TO ANY CONST EXCAVATION (811) 5. PRIOR TO APPLICATION FOR BUILDING PERMIT, THE MUNICIPAL SEWER LINES WILL BE INSPECTED BY CCTV, AND CITY RECORDS WILL BE RESEARCHED TO CONFIRM STATUS OF PRIOR SEWER AND WATER SERVICE DISCONNECTS. ALL PRIOR UTILITIES WILL BE PROPERLY ABANDONED TO THE SATISFACTON OF THE CITY OF SALEM ENGINEERING DEPARTMENT AND ANY DEFECTS DISCOVERED IN THE SANITARY MAIN BY THE CCTV PROCESS WILL BE REMEDIED. 6. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL FIELD VERIFY: 6.1. PROPERTY BOUNDARIES, EASEMENTS, AND RIGHT OF WAYS. 6.2. EXSTG STRUCTURES, BUILDINGS, AND DRIVEWAYS 6.3. LOCATIONS, SIZES, DEPTHS OF EXSTG UG UTILITIES, PIPING, STRUCTURES, TANKS, ETC. 6.4. ALL EXSTG AND PROPOSED CRITICAL ELEVATIONS 7. ALL DEMOLITION MATERIALS WILL BE PROPERLY DISPOSED. 8. WHERE CONFLICTS ARISE BETWEEN FIELD CONDITIONS & PROPOSED CONST, OR IF THERE IS A CONFLICT BETWEEN ANY REGS OR MUNICIPAL REQMNTS AND PROPOSED PLANS, CONTRACTOR SHALL NOTIFY OWNER'S REP PRIOR TO CONTINUANCE OF WORK. SCALE PROJECT ADDRESS SHEETDWG FILE PLAN A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. DEMOLITION C-1.1AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 DE S C R I P T I O N RE V BY DA T E 08 N O V 2 0 2 1 0 A G O R I G I N D A T E O F D R A W I N G REFERENCE: PROPERTY LINES AND OTHER EXISTING SITE IMPROVEMENT INFORMATION ON THIS DRAWING TAKEN FROM EXISTING CONDITIONS PLAN BY EASTERN LAND SURVEY, ASSOC, INC., SHEET F 19120, 05 APRIL 2021, SCALE 1"=20'. ALL SITE IMPROVEMENTS ARE SHOWN PER THE BEST AVAIL INFO AND MUST BE VERIFIED IN THE FIELD, PARTICULARLY PRIOR TO ANY EXCAVATION OR WORK THAT MAY AFFECT BURIED UTILITIES. 3/25/24 18 LAYOUT OF PROPOSED SITE IMPROVEMENTS SEE GRAPHIC SCALE L E G E N D 30 N O V 2 0 2 1 1 A G A D D E D F O R M E R R E S I D E N C E L O C A T I O N S & U T I L I T Y N O T E 24 M A R 2 0 2 4 2 A G R E V P E R M A D O T C M T S - M A K E W C R s M E E T S T D s A N D I N S T A L L S I L T S A C HIGHLAND AVENUE B A R C E L O N A A V E N U E UP UP UP G7 NO TP LEDGE 24 " 122.0 G1 LEDGE 57 " 123.3 1 2 4 1 2 6 1 2 8 13 0 12 2 1 2 2 1 2 0 124 1 2 6 12 0 11 8 126 127 1 2 8 12 9 13 0 13 1 126 1 2 5 12 4 FF - 126.9 7 126.72 126.95x x 126.95x 123 126.84 x 126.98 x 126.76 x 126.58 x 126.64 x 126.87x 1 1 9 1 2 0 1 2 2 12 7 1 1 7 1 2 1 11 7 1 1 8 1 1 9 1 2 0 12 1 12 2 1 2 3 1 1 8 1 2 4 1 2 5 13 0 128 12 6 124 127.26 x 126.65 x 126.95 x 36+0 37+0 39+038+0 130.82 118.76 119.01 LE D G E @ 2 ' A L O N G T R E N C H G8 NO TP LEDGE 24 " 119.0 G2 SHGW 116 " 113.4 NO LEDGE 1 4 6 " <110.9 G3 SHGW 104 " 114.4 NO LEDGE 1 2 0 " <113.1 G4 SHGW 144 " 116.0 NO LEDGE 1 5 4 " <115.2 G5 SHGW 100 " 115.7 NO LEDGE 1 4 0 " <112.4 G6 SHGW @ L E D G E LEDGE 80 " 115.4 G9 SHGW @ L E D G E LEDGE 81 " 114.3 1 2 5 12 8 12 9 125 1 2 4 124 1 2 4 125 12 7 12 8 12 6 . 0 126.90 x 122.95 x 122.20 x 122.80 x 12 2 1 2 0 1 1 8 1 2 2 1 1 8 1 2 2 122.40 x 122.60 x 125 124 12 1 SMH R-132.81 I-121.1 SMH R-130.10 I-118.7 (R e c o r d ) SMH R-122.19 I-116.9 (R e c o r d ) 1 2 0 13 0 1 2 9 129 127 1 2 8 1 2 7 126 12713 2 129 13 1 12 5 125 125 1 2 3 12 3 123 123 1 2 5 1 2 4 1 2 8 1 2 7 1 2 6 127 126.37 x 1 2 6 1 2 3 126.65 x 126.95 x x 126.87x 126.37 x ~143.5 (bottom fa s c i a ) (min 15' c l e a r a n c e ) CB4(trench) R-125.25 I-122.58 ~124.5 (top a l l f t g s ) ~119.5 (bo t t o m f t g s ) CB3(trench) R-~124.08 I(out)-121.43 CB1 R-126.32 I-123.55 SC1(450i) R-124.65 I(in)-120.60 I(out)-120.27 INFILTRA T I O N S Y S I(in)-120.1 7 RS-12 @ 1 1 8 . 8 4 Bottom Sys - 1 1 8 . 3 4 1 2 3 1 1 9 UP 1 3 0 1 3 2 132. 2 5 x 131 . 0 4 x131. 9 4 x 132. 0 6 x 131. 4 0 x 131. 9 2 x132. 7 4 x 132 . 7 9 x 131 . 1 5 x 131 . 9 3 x 131. 9 5 x 131. 2 4 x131. 8 7 x132 . 0 9 x 131 . 2 9 xx132. 0 6 x 131. 2 8 x131. 5 2 x 131 . 8 1 x 130 . 5 9 x131. 3 9 x 131 . 7 0 x 130. 7 0 x 130. 2 7 x130. 5 9 x 131. 6 6 CB5 R-130.39 I-126.80 131.45 x 131.32 x 131.32 x 131.54 x 13 1 131.25 x 131.25 x 131. 2 9 x x131. 2 2 OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW 13 4 13 6 13 8 14 0 131.75 x 131.78 x 128.85 x 130.62 x CB2 R-124.75 I-122.25 125.09 tc 124.59 bc x 125.17 x 124.93 124.98 x xx 12 6 . 9 0 12 4 . 3 7 t c 12 3 . 9 5 b c x 124.57 x 123 . 0 8 x123.97x 124.01x x 122.26 x 122.31x 12 3 . 0 4 12 3 . 0 8 12 2 . 9 9 xx 12 3 . 1 1 t c 12 2 . 7 4 b c x 12 2 . 3 1 x 12 3 . 0 1 t c 12 2 . 5 1 b c x 12 2 . 5 3 x12 4 . 0 1 x x 12 4 . 4 8 t c 12 3 . 9 8 b c 124.98 x12 5 . 5 0 x x 12 6 . 8 2 t c 12 6 . 3 2 b c x 12 5 . 4 5 x 125.50 12 6 . 5 1 t c 12 6 . 0 1 b c x 12 6 . 5 9 x 124.81 x x 123 . 0 4 x 12 2 . 9 5 DB2 R-124.40 (no grate) I(in)-121.48 I(out)-121.32 124 x 125.50 125.25 xx124.11 124.10 DB3 R-125.45 (no grate) I(in1)-122. 5 0 I(in2)-123. 2 5 I(out)-122 . 1 4 DB1 (no grate) R-124.40 I(in1)-121.58 I(in2)-121.06 I(in3)-121.03 (out)-120.90 OIL/GRIT R-124.60 I(in1)-120.82 I(in2)-121.07 I(in3)-121.26 (out)-120.66 LAYOUT OF PROPOSED SITE GRADING SEE GRAPHIC SCALE SCALE PROJECT ADDRESS SHEETDWG FILE GRADING DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. C-2AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 24 M A Y 2 0 2 1 0 A G O R I G I N A L D R A W I N G D A T E GENERAL NOTES 1. THE CONTRACTOR SHALL CONTACT DIG-SAFE PRIOR TO ANY CONSTRUCTION EXCAVATION (811 IN MA) 2. SITE GRADES VARY APPROX 14 FEET ACROSS THE PROPERTY, CONTOURS SHOWN AT ONE FOOT INTERVAL. 3. OWNER WILL HAVE SURVEYOR CONFIRM LOCAL TEMP BM AT HYDRANT ALONG FRONTAGE PRIOR TO START OF CONSTRUCTION AND CONTRACTOR WILL MAINTAIN AND PROTECT THE BM THROUGHOUT THE PROJECT 4. WHERE CONFLICTS ARISE BETWEEN THE FIELD CONDITIONS VERIFIED AND PROPOSED CONSTRUCTION, OR IF THERE IS A CONFLICT BETWEEN ANY REGULATIONS OR MUNICIPAL REQUIREMENTS AND THE PROPOSED PLANS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO CONTINUANCE OF THE WORK. 5. THIS PROJECT WILL REQUIRE A GRADING ALTERATION PERMIT AND APPLICABLE FEE SUBMITTED TO THE CITY OF SALEM ENGINEERING DEPARTMENT PRIOR TO THE SUBMITTAL OF A BUILDING PERMIT APPLICATION. 19 20 J U L 2 0 2 1 1 A G R E V P E R P L N G B D C M T S - R E D U C E D P V M N T , A D D E D T R E E S , E T C 02 S E P 2 0 2 1 2 A G R E V P E R P V M N T C H A N G E S L E G E N D 3/25/24 08 N O V 2 0 2 1 4 A G R E V P E R P E E R R E V I E W 30 N O V 2 0 2 1 5 A G R E V P E R U P D A T E D S T O R M W A T E R 24 M A R 2 0 2 4 6 A G R E V P E R M A D O T C M T S 126 127 1 2 8 12 9 13 0 13 1 126 1 2 5 12 4 1 1 9 1 2 0 12 7 1 2 1 36+0 37+0 39+038+0 1 2 5 12 8 12 9 125 1 2 4 124 1 2 4 125 127 12 6 . 0 12 2 1 1 8 1 2 2 125 124 12 1 NEW SERV I C E T I E I~120.5 (E s t m d ) NEW SEW E R SERVICE I~123.0 NEW 1.0" COPPER (TYPE K) WATER SVC 8 " R C P S E W E R 16" WATER 12" SEWER 13 0 1 2 9 1 2 8 1 2 7 126 125 1 2 3 12 3 123 123 127 1 2 6 1 2 3 CB4(trench) R-125.25 I-122.58 CB3(trench) R-~124.08 I(out)-121.43 CB1 R-126.32 I-123.55 SC1(450i) R-124.65 I(in)-120.60 I(out)-120.27 INFILTRA T I O N S Y S I(in)-120.1 7 RS-12 @ 1 1 8 . 8 4 Bottom Sys - 1 1 8 . 3 4 D 3 8 " A D S 2 4 ' - 1 . 5 % D 0 1 1 2 " A D S - 1 4 2 ' - 1 . 7 5 % D0 8 8 " S D R - 3 5 P V C 13 9 ' - 1 . 7 5 % D1 2 6 " P V C 83 ' - 4 . 2 % 6" P V C 58 ' - 2 . 0 % D11 15" ADS 3.3' - 3.0% 195 LF 6" SDR-35 PVC @ 1.3% D4 8" ADS 5' - 1.6% D5 12" ADS 131' - 2.7% CB5 R-130.39 I-126.80 6" C I W A T E R SMH R-130.10 I-118.7 (R e c o r d ) SMH R-132.81 I-121.1 13 1 OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW CB2 R-124.75 I-122.25 12 3 1 3 D 1 0 15 " A D S 3' - 2 . 0 % WG WG D6 15" ADS 41' - 1.6% 1 2 DB2 R-124.40 (no grate) I(in)-121.48 I(out)-121.32 124 2 CO DB3 R-125.45 (no grate) I(in1)-122 . 5 0 I(in2)-123. 2 5 I(out)-122. 1 4 D2 12" ADS 11'-2.0% DB1 (no grate) R-124.40 I(in1)-121.58 I(in2)-121.06 I(in3)-121.03 (out)-120.90 D9 15" ADS 4'-2.0% D7 15" ADS 4'-1.5% OIL/GRIT R-124.60 I(in1)-120.82 I(in2)-121.07 I(in3)-121.26 (out)-120.66 NEW O H E L E C T R I C S V C LAYOUT OF PROPOSED SITE IMPROVEMENTS SEE GRAPHIC SCALE SCALE PROJECT ADDRESS SHEETDWG FILE UTILITIES DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. C-3AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 24 M A Y 2 0 2 1 0 A G O R I G I N A L D R A W I N G D A T E GENERAL NOTES 1. THE CONTRACTOR SHALL CONTACT DIG-SAFE PRIOR TO ANY CONSTRUCTION EXCAVATION (811 IN MA). 2. ALL NEW UTILITY SERVICES WILL BE INSTALLED IAW CITY ENGINEERING DEPARTMENT REQUIREMENTS. 3. A NEW 6" SEWER SERVICE IS PROPOSED TO TIE INTO MAIN ON BARCELONA AND IAW WITH UTILITY PERMIT AND REQUIREMENTS. THE SEWER LINE ALONG BOTH PROPERTY FRONTAGES WILL BE INVESTIGATED BY CCTV TO CONFIRM CONDITION, LOCATION, AND INVERT. IF ANY PRIOR CONNECTIONS STILL REMAIN, THEY WILL BE CLOSED IAW CITY ENGINEER REQUIREMENTS. 4. NEW 1" WATER SERVICE IS PROPOSED TO TIE INTO MAIN ON BARCELONA IAW UTILITY PERMIT AND REQUIREMENTS. 5. A.L. PRIME OR ITS INSTALLATION CONTRACTOR WILL OBTAIN UTILITY APPROVALS AND PAY WATER CONNECTION FEES AS APPLICABLE PRIOR TO ANY WATER UTILITY WORK. 6. A NEW OVERHEAD ELECTRIC SERVICE IS PROPOSED TO BE ROUTED FROM EXISTING POLE ALONG BARCELONA TO A NEW POLE ALONG THE PROPERTY SIDELINE NEAR THE PROPOSED EV CHARGING STATION AND ON TO THE STORE. 7. NO BURIED TELECOMMUNICATIONS ARE PROPOSED IN EITHER R.O.W. 8. WHERE CONFLICTS ARISE BETWEEN THE FIELD CONDITIONS VERIFIED AND PROPOSED CONSTRUCTION, OR IF THERE IS A CONFLICT BETWEEN ANY REGULATIONS OR MUNICIPAL REQUIREMENTS AND THE PROPOSED PLANS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO CONTINUANCE OF THE WORK. 9. PROPOSED WORK INCLUDES THE INSTALLATION OF NEW SUBSURFACE STORMWATER INFILTRATION SYSTEM FOR THE BUILDING AND CANOPY ROOF DRAINS AND ALL PAVEMENT AREA. SEE STORMWATER PLAN FOR LAYOUT OF SYSTEM. 10. IT IS INTENDED TO LEAVE UNCHANGED THE EXISTING FIRE HYDRANT IN THE ROW NEAR THE INTERSECTION OF HIGHLAND AVE AND BARCELONA. 11. SEE SEPARATE TANK AND PIPING PLANS FOR LAYOUT OF MOTOR FUEL AND VENT PIPING. 12. THIS PROJECT WILL NOT REQUIRE ANY TEMPORARY WATER USE. 13. WATER LINE TO BE SLEEVED MINIMUM 10' EACH SIDE OF ANY CROSSOVER WHERE IT IS BELOW SANITARY OR FUEL PIPING. 14. ALL UG PIPING AND CASTINGS TO BE H-20 RATED. ANTICIPATED WATER AND SEWER RQMNTS 1. ANTICIPATED WATER AND SEWER MAXIMUM FLOWS OF 500 GALLONS PER DAY BASED ON MA TITLE V AND SIMILAR STATION EXPERIENCE: 1.1. RETAIL STORE - (MIN) 200 GPD 1.2. MOTOR FUEL - (MIN) 300 GPD 2. WATER AND SEWER FLOWS ARE EQUAL, NO IRRIGATION SYS TIED TO DOMESTIC SERVICE. IF ANY IRRIGATION SYS TO BE INSTALLED, IT WILL UTILIZE SEPARATE ON-SITE IRRIGATION WELL NOT CONNECTED TO THE DOMESTIC SERVICE. 3. PEAK FLOW BASED ON SIMULTANEOUS OPERATION OF ALL INSTALLED FIXTURES (TWO RESTROOMS, PLUS THREE SINKS, PLUS HOSE BIB) = 52 GAL/MIN PEAK FLOW. 4. PRIOR TO BUILDING PERMIT APPLICATION, OWNER OR REPRESENTATIVE WILL SUBMIT AN ENGINEERING STATEMENT CONFIRMING THAT THE MAINS HAVE ADEQUATE CAPACITY FOR THE PROPOSED DEVELOPMENT. 5. THE LICENSED PLUMBING CONTRACTOR WILL PROVIDE DESIGN AND DEVICE DATA SHEETS TO THE BUILDING AND ENGINEERING DEPTS AS PART OF THE PLUMBING PERMIT APPLICATION. THERE WILL ONLY BE ONE METER FOR THIS LOCATION AND ALL BACKFLOW DEVICES REQUIRED AT THE METER AND AT FOOD SERVICE EQUIPMENT WILL BE INSTALLED IAW MA REGULATIONS. 20 02 S E P 2 0 2 1 1 A G R E V P V M N T A N D P K G , N O C H A N G E T O U T I L I T I E S L A Y O U T L E G E N D 08 N O V 2 0 2 1 2 A G R E V P E R P E E R R E V I E W 3/25/24 30 N O V 2 0 2 1 3 A G R E V P E R P E E R R E V I E W 24 M A R 2 0 2 4 4 A G R E V P E R M A D O T C M T S - C H A N G E D C B 3 & 4 T O T R E N C H D R A I N S 1 2 4 1 2 6 1 2 8 13 0 12 2 1 2 2 1 2 0 124 1 2 6 1 2 0 11 8 126 127 1 2 8 12 9 13 0 13 1 126 1 2 5 12 4 123 1 1 9 1 2 0 1 2 2 12 7 1 1 7 1 2 1 11 7 1 1 8 1 1 9 1 2 0 12 1 12 2 1 2 3 1 1 8 1 2 4 1 2 5 13 0 128 12 6 124 36+0 37+0 39+038+0 1 2 5 12 8 12 9 125 1 2 4 124 1 2 4 125 127 12 8 12 6 . 0 12 2 1 2 0 1 1 8 1 2 2 1 1 8 1 2 2 125 124 12 1 1 2 0 13 0 1 2 9 129 127 1 2 8 1 2 7 126 12713 2 129 13 1 12 5 125 125 1 2 3 12 3 123 123 1 2 5 1 2 4 1 2 8 1 2 7 1 2 6 127 1 2 6 1 2 3 1 2 3 1 1 9 1 3 0 13 1 OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW 13 4 13 6 124 LAYOUT OF EROSION CONTROL MEASURES SEE GRAPHIC SCALE SCALE PROJECT ADDRESS SHEETDWG FILE CONTROL DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. ER-1AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 24 M A Y 2 0 2 1 0 A G O R I G I N A L D R A W I N G D A T E EROSION EROSION CONTROL AND SOIL STABILIZATION 1. ALL DISTURBED SLOPES SHALL BE STABILIZED WITH TEMPORARY TREATMENT SUCH AS EROSION CONTROL BLANKETS OR HYDRO SEEDED AND PROTECTED WITHIN ONE WEEK OR BEFORE ANY EXPECTED STORM EVENT. 2. EROSION CONTROL MEASURES SHALL BE INSPECTED AND MAINTAINED DAILY 3. TOPSOIL SHALL HAVE A SANDY LOAM TEXTURE RELATIVELY FREE OF SUBSOIL MATERIAL, STONES, ROOTS, TREE LIMBS, TRASH OR CONSTRUCTION DEBRIS 4. DESIGN SEED MIX SHALL BE COMPRISED OF THE FOLLOWING SEED RATE MIXTURE 4.1. PER ACRE: 20 LBS TALL FESCUE, 20 LBS CREEPING RED FESCUE, 8 LBS BIRDSFOOT TREFOIL. 4.2. PER 1,000 SF: 0.45 LBS TALL FESCUE, 0.45 LBS CREEPING RED FESCUE, 0.20 LBS BIRDSFOOT TREFOIL. 5. TEMPORARY TREATMENTS SHALL CONSIST OF HAY, STRAW, FIBER MULCH, OR PROTECTIVE COVER SUCH AS BURLAP, JUTE, FIBERGLASS NETTING OR BLANKETS. HAY OR STRAW SHOULD BE APPLIED AT MAXIMUM OF 3 TONS PER ACRE. 6. ALL TEMPORAY PROTECTION INCLUDING SILT FENCE, HAY BALES OR STRAW WATTLES SHALL REMAIN IN PLACE UNTIL AN ACCEPTABLE STAND OF GRASS OR GROUND COVER IS ESTABLISHED. 7. ALL FILL SHALL BE THOROUGHLY COMPACTED UPON PLACEMENT. 8. STOCKPILES OF TOPSOIL SHALL NOT BE LOCATED NEAR WATERWAYS AND SHALL HAVE MAX SIDE SLOPE LESS THAN 2:1. 9. CONTRACTOR TO TAKE WHATEVER MEASURES APPROPRIATE DURING EACH PHASE OF WORK TO DIVERT RUNOFF AROUND DISTURBED AREAS AND TO LIMIT THE AMOUNT OF RUNOFF FLOWING INTO OR THROUGH DISTURBED AREAS. TEMPORARY STABILIZATION 1. ESTIMATED TIME OF CONSTRUCTION FOR THIS PROJECT IS FIVE MONTHS. 2. TEMPORARY CONTROL MEASURES AND ANY REQUIRED MA DEP SIGNAGE TO BE INSTALLED PRIOR TO ANY SITE WORK OR DEMO OF EXISTING IMPROVEMENTS. 3. INSTALL PERIMETER FENCING, SILT CONTROLS, CONSTRUCTION ENTRANCES AND ESTABLISH STOCKPILE AREAS PRIOR TO SITE WORK EXCAVATION. INSTALL SILT SAC PROTECTION AT CATCH BASIN ALONG HIGHLAND AVE INCLUDING CB APPROX 100' NORTH OF SITE NEAR FOREST RIVER. 4. THROUGHOUT THE COURSE OF THE WORK, MAINTAIN EROSION AND SEDIMENTATION CONTROL STRUCTURES AS NECESSARY TO KEEP ALL OPERATING AS INTENDED. 5. DRAINAGE SHALL BE PREVENTED FROM ENTERING SUBSURFACE INFILTRATION SYSTEM BEFORE THE SYSTEM IS COMPLETED AND BACKFILLED. 6. TEMPORARY HAY BALES, STRAW WATTLES, OR SILT FENCES MAY BE REMOVED AFTER FINAL SOIL STABILIZATION AND BASE PAVEMENT HAS BEEN INSTALLED AND ISSUANCE OF ANY REQUIRED APPROVAL FROM MUNICIPAL AUTHORITY. 7. CATCH BASIN INLET PROTECTION MUST REMAIN UNTIL BASE PAVEMENT IS INSTALLED AND ALL STOCKPILES ARE REMOVED AND NO LONGER NECESSARY. 8. AT THE CONCLUSION OF CONSTRUCTION AND AFTER ALL FINAL STABILIZATION IS ACHIEVED, CLEAN ALL DRAINAGE STRUCTURES OF ALL DIRT, DEBRIS, OR ANY LOOSE MATERIALS. CONSTRUCTION SEQUENCE 1. CARE SHALL BE TAKEN TO PREVENT ANY UNSUITABLE MATERIAL FROM ENTERING ROADWAYS OR ANY DRAINAGE STRUCTURE. 2. PROTECT ALL INLETS, STOCKPILES AND UN-ESTABLISHED SOIL AREAS DURING STORMS AND PERIODS OF RAINFALL. 3. INSPECT ALL SEDIMENTATION CONTROL DEVICES PROMPTLY AFTER EACH RAINFALL AND REPAIR OR CLEAN OUT SEDIMENTATION AS NECESSARY. 4. INSTALL ADDITIONAL CONTROL MEASURES AS NECESSARY AS CONDITIONS WARRANT. 5. AT THE END OF EACH WORK DAY, COVER ALL STOCKPILES AND INSURE ALL SEDIMENTATION CONTROL DEVICES ARE IN PLACE. STOCKPILE SIDE SLOPES SHALL NOT BE GREATER THAN 2:1. 6. SEDIMENT SHALL BE REMOVED FROM SILT WATTLE BARRIER ONCE THE VOLUME REACHES 1 4 HEIGHT OF THE WATTLE. 7. CONSTRUCT AND MAINTAIN A TEMPORARY CONSTRUCTION ENTRANCE PRIOR TO EXISTING PAVED AREAS ARE DISTURBED AND CONSTRUCTION VEHICLES START TRACKING SEDIMENTATION INTO THE ROADWAY. CONSTRUCTION ENTRANCE(S) WILL BE MONITORED AND CLEANED OF SEDIMENT AS NEEDED ON A DAILY BASIS. SWEEP THE CONSTRUCTION SITE AND ENTRANCES AS NECESSARY TO PREVENT TRACKING OF SEDIMENTATION INTO THE ROADWAY. 8. TOPSOIL SHALL BE STRIPPED FROM AREAS TO BE DISTURBED, STOCKPILED IN APPROVED AREAS AND STABILIZED WITH TEMP VEGETATIVE COVER IF TO BE LEFT STOCKPILED FOR MORE THAN 30 CALENDAR DAYS. 9. MAINTAIN PROPER DUST CONTROL THROUGHOUT THE PROJECT. 10. INSTALL A CONTINUOUS LINE OF SEDIMENTATION CONTROL ALONG THE PERIMETER OF ALL CONSTRUCTION ACTIVITY PER THE EROSION CONTROL SITE PLAN. 11. PROTECT THE INLET OF ALL CATCH BASINS SUBJECT TO POSSIBLE RUNOFF FROM THE SITE WITH SEDIMENT FILTER AND INSPECT THE FILTER AFTER ALL RAINFALLS AND ANY RUNOFF THAT REACHES THE CATCH BASIN. 12. INSURE PROPER HANDLING OF CONCRETE WASH OR OTHER CONSTRUCTION ACTIVITY TO PREVENT ANY SUCH WASH FROM REACHING THE CATCH BASIN OR ROADWAY. 13. REMOVE SEDIMENTATION CONTROL AT ALL CBs UPON COMPLETION OF ALL WORK SO IT DOESN'T HINDER NORMAL DRAINAGE. SEDIMENTATION CONTROL AND CONSTRUCTION OPN AND MAINT PLAN 1. UPON COMPLETION OF CONSTRUCTION, STORM WATER CONTROLS ARE TO BE MAINTAINED IN ACCORDANCE WITH FOLLOWING PERMANENT PROCEDURES: 1.1. CATCH BASINS SHALL BE INSPECTED AT LEAST ANNUALLY AND CLEANED AS NECESSARY 1.2. MAINTAIN A WRITTEN EMERGENCY RESPONSE PROCEDURE AND TRAIN ALL SITE EMPLOYEES HOW TO RESPOND IN CASE OF ANY SPILL 1.3. PAVED AREAS SHOULD BE SWEPT AT LEAST ANNUALLY IN SPRING TO REMOVE SEDIMENT ACCUMULATED THROUGH THE WINTER 2. LANDSCAPE AREAS ARE TO BE MAINTAINED AND ANY BARE SOIL IN GRASSED AREAS SHALL BE RE-SEEDED. 3. SEE WRITTEN OPERATION AND MAINTENANCE PLAN SUBMITTED AS PART OF SITE PLAN APPLICATION. POST CONSTRUCTION SEE DETAIL SHEETS FOR ADDITIONAL DETAILS 21 02 S E P 2 0 2 1 1 A G A D J F O R R E V I S E D P A V E M E N T L E G E N D 3/25/24 08 N O V 2 0 2 1 2 A G R E V P E R P E E R R E V I E W 30 N O V 2 0 2 1 3 A G M I N O R A D J U S T M E N T S T O S E D I M E N T A T I O N B A R R I E R 24 M A R 2 0 2 4 4 A G R E V P E R M A D O T C M T S - A D D E D S I L T S A C A T D O T C B X X 6K S U L 6K D S L 12 K R U L 12 K R U L 4K def OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW TANK AND PIPING LAYOUT SEE GRAPHIC SCALE SCALE PROJECT ADDRESS SHEETDWG FILE TANK & PIPING DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. TK-1AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 24 M A Y 2 0 2 1 0 A G O R I G I N A L D R A W I N G D A T E LAYOUT 1. REMOVE ALL EXISTING SITE IMPROVEMENTS 2. INSTALL FOUR NEW UG DW FG MOTOR FUEL TANKS 3. INSTALL NEW TANK TOP EQUIPMENT AND FUEL PRODUCT PIPING, INCLUDING NEW DW SPILL CONTAINMENT, MONITORED TANK SUMPS, AND TANK AND PIPING MONITORING SENSORS AND PROBES, VENT PIPING AND VENT RISERS. 4. INSTALL NEW CONCRETE PAVING OVER TANKS AND THROUGHOUT FUELING AREA 5. INSTALL NEW DISPENSERS AT NEW ISLANDS WITH SUMPS AND SUMP SENSORS 6. INSTALL NEW DRY CHEMICAL FIRE SUPPRESSION SYSTEM AT FUELING AREA PER FD APPROVED PLAN 1. THIS PLAN TO BE USED IN CONJUNCTION WITH OTHER SITE AND ARCHITECTURAL PLANS. THIS PLAN ONLY FOR UG TANK INFORMATION, REFER TO OTHER PLANS FOR LAYOUT AND SPEC'S RELATED TO OTHER SITE IMPROVEMENTS. 2. UG STORAGE TANK FACILITIES IN MA ARE REGULATED UNDER 310 CMR 80.00. FACILITY OWNERS, OPERATORS AND INSTALLERS ARE SUBJECT TO THESE REGS. THIS UG TANK WORK SHALL COMPLY WITH ALL APPLICABLE REGS, ALL REQMNTS OF FEDERAL, STATE, AND LOCAL CODES INCLUDING, BUT NOT LIMITED TO, OSHA. TANKS, PIPING, AND ALL TANK OR PIPING RELATED EQUIP SHALL BE INSTALLED IN ACCORDANCE WITH MFGR'S RECOMMENDATIONS AND/OR SPECS. 3. THE PROPERTY IS NOT LOCATED WITHIN 100' BUFFER TO VEGETATED WETLANDS BUT IS PARTIALLY LOCATED IN 200FOOT RIVERFRONT PROTECTION AREA. NO TANKS OR PIPING ARE PROPOSED TO BE LOCATED IN THE RIVERFRONT AREA. ALL WORK TO BE DONE IAW ALL APPROVAL CONDITIONS OF THE CITY OF SALEM CONSERVATION COMMISSION. 4. THE CONTRACTOR WILL BE RESPONSIBLE FOR OBTAINING ANY APPLICABLE PERMITS FROM THE LOCAL FIRE DEPARTMENT AND TRADE OR BUILDING PERMITS FROM THE LOCAL BLDG DEPT AND FOR COMPLYING WITH ALL ASSOCIATED TESTING AND INSPECTION REQMNTS. 5. THE CONTRACTOR SHALL CONTACT DIG-SAFE PRIOR TO ANY CONSTRUCTION EXCAVATION (811) 6. MA LSP OR DESIGNATED REPRESENTATIVE TO WITNESS EXISTING TANK REMOVAL AND SAMPLE SOIL FROM SIDES AND BOTTOM OF EXCAVATION FOR ANALYSIS AND PREPARE ANY REQUIRED REPORTING IN ACCORDANCE WITH ALL MA DEP TANK CLOSURE REQUIREMENTS. 7. THE CONTRACTOR SHALL FIELD VERIFY THE FOLLOWING ITEMS PRIOR TO CONSTRUCTION: LOCATION OF PROPERTY BOUNDARIES, EASEMENTS, AND RIGHT OF WAYS; LOCATIONS OF STRUCTURES, BUILDINGS, AND DRIVEWAYS; LOCATIONS, SIZES, DEPTHS OF EXSTG UG UTILITIES, PIPING, STRUCTURES, TANKS, ETC.; AND EXSTG AND PROPOSED CRITICAL ELEVATIONS 8. WHERE CONFLICTS ARISE BETWEEN FIELD CONDITIONS VERIFIED AND PROPOSED CONSTRUCTION, OR IF THERE IS A CONFLICT BETWEEN ANY REGULATIONS OR MUNICIPAL REQUIREMENTS AND THE PROPOSED PLANS, THE CONTRACTOR SHALL NOTIFY THE OWNER'S REPRESENTATIVE PRIOR TO CONTINUANCE OF THE WORK. 9. GW IS EXPECTED BELOW BOTTOM OF TANK EXCAVATION SO CONSTRUCTION DEWATERING IS NOT EXPECTED TO BE BE REQUIRED. DEWATERING PROCESS AND WATER DISPOSAL WILL BE ACCOMPLISHED IAW DEWATERING PLAN AS DEVELOPED BY THE ENVIRONMENTAL LSP. ALL DEWATERING WILL BE DONE IN IAW MA DEP REQMNTS AND REGS AND ALSO WITH ANY LOCAL MUNICIPAL REQMNTS. 10. TANKS WILL BE SECURED BY DEADMEN ANCHORS SIZED TO PREVENT FLOATOUT EVEN IN THE EVENT OF WORST CASE FULL FLOOD AND EMPTY TANK CONDITIONS. 11. FOLLOW SAFETY PRECAUTIONS DUE TO SAFETY HAZARDS CREATED BY AIR TESTING - FAILURE OF TANKS OR PIPING UNDER AIR TEST MAY CAUSE SEVERE PERSONAL INJURY OR DEATH. 1. TANKS TO BE HANDLED AND INSTALLED IN ACCORDANCE WITH ALL TANK MFGR INSTALLATION INSTRUCTIONS. 2. PROVIDE CLEAN STONE BED AND LAYOUT ALL DEADMEN PER MFGR SPECIFICATIONS. INSTALL HOLD DOWN STRAPS AT INDICATED LOCATIONS ON TANK. BACKFILL TANK WITH PARTICULAR ATTENTION TO FILL AREA NEAR BOTTOM OF TANK REQUIRING MANUAL CHOCKING OF STONE, FOLLOW ALL MFGR RECOMMENDED BACKFILL PROCEDURES. 3. INSURE ALL TANKS PROPERLY BALLASTED AND PROTECTED DURING ALL WORK. 4. TANK TO BE BACKFILLED TO GRADE WITH TANK MFGR RECOMMENDED BACKFILL MAT'L AND COVERED WITH 8" REINF CONC MAT EXTENDING A MIN OF TWO FT BEYOND THE TANK SHADOW IN ALL DIRECTIONS. 5. ALL METAL RISERS AND BURIED PORTIONS OF VENT RISERS TO BE SCHEDULE 40 AND COATED TO PROTECT FROM CORROSION 6. ALL PIPING SHALL MEET UL-971 AND APPLICABLE ASTM STANDARDS. 7. PRODUCT PIPING TO BE FRANKLIN FUELING APT DOUBLE WALL FLEXIBLE PIPING INSIDE OF FLEXIBLE DUCT, VENT/VAPOR PIPING TO BE NOV 3000 SW FG. ALL PIPING WILL BE SLOPED BACK TO A MONITORED SUMP AT MIN 18" PER FOOT AND WILL BE INSTALLED IAW MFGR INSTALLATION GUIDELINES, RECOMMENDATIONS OR SPECS. INSPECT ALL PIPING PRIOR TO INSTALLATION FOR ANY SHIPPING OR HANDLING DAMAGE. 8. AFTER ALL NEW PIPING IS INSTALLED, BUT PRIOR TO BACKFILLING, THE PRIMARY AND SECONDARY LINES ARE TO BE DISCONNECTED FROM THE TANKS AND DISPENSERS, FLEX CONNECTORS INCLUDED, AND PLUGGED OR CAPPED. THE LIQUID AND VAPOR PRIMARY LINES SHALL THEN BE TESTED. AT A MIN, TEST PRIMARY PIPING AT 50 TO 60 PSIG FOR AT LEAST 4 HRS AND SOAP TEST ALL FITTINGS. TEST SECONDARY PIPING AT 6PSI OR SMALLEST MAX RATING OF ANY COMPONENT (DO NOT EXCEED RATING OF ANY COMPONENT) FOR MINIMUM OF 4 HRS AND SOAP TEST ALL FITTINGS. IF TESTING PRIMARY AND SECONDARY SIMULTANEOUSLY, MAINTAIN MIN 10P PSI DIFFERENCE IN TEST PRESSURES. 9. TEST ALL VENT PIPING PRIOR TO BACKFILL IN ACCORDANCE WITH PIPING MFGR'S INSTALLATION INSTRUCTIONS. SEPARATE PIPING FROM TANK BY INSERTING PLUG INTO EXTRACTOR VALVE AND OPEN OTHER TANK FITTINGS TO PREVENT BUILDUP OF EXCESSIVE PRESSURE INSIDE THE TANK. VISUALLY INSPECT ALL BONDED JTS AND MAKE ANY NECESSARY REPAIRS PRIOR TO PRESSURIZING PIPING SYSTEM. CHECK INTEGRITY OF JTS BY PRESSURIZING TO MAX 50 PSIG AND SOAP TEST ALL JTS. 10. ONCE THE SECONDARY LINE IS TESTED, TEST FITTINGS WILL BE LOOSENED AND MOVED BACK TO ALLOW COMMUNICATION BETWEEN THE INTERSTITIAL SPACES AND THE SUMPS. 1. ALL SUMPS TO BE WATERTIGHT TO PREVENT LEAKS FROM OR WATER INTRUSION INTO SUMP. MEASURES PROPOSED TO PREVENT WATER INTRUSION INCLUDE CROWNING OF CONC TANK PAD AROUND SUMPS, MANHOLES AND SUMPS WITH WATERTIGHT GASKETED LIDS, AND WATERTIGHT BULKHEAD ENTRY FITTINGS 2. ALL NEW OR MODIFIED SUMPS, INCLUDING SPILL CONTAINMENT BUCKETS SHALL BE TESTED IAW MA DEP REQUIRMNTS. 3. ALL CONDUIT AND PIPING INSTALLED AND TERMINATION FITTINGS, SEAMS AND FITTINGS TIGHT AND/OR CLOSED. FILL EACH SUMP AND SPILL BUCKET TO WITHIN 1 INCH OF THE TOP OF THE SUMP AND MONITORING WATER LEVEL FOR 1 HR MIN WITHOUT ADDITION OF LIQUID TO THE SUMP. VISUALLY INSPECT THE OUTSIDE OF THE SUMP FOR ANY EVIDENCE OF WATER LEAKAGE AND THE INSIDE FOR ANY AIR BUBBLES INDICATING A LEAK. A PASSING TEST SHALL HAVE NO LOSS OF LIQUID OR OBSERVED LEAKS. 1. ALL BACKFILL MATL SHALL MEET TANK AND/OR PIPING MFGR'S INSTALLATION SPEC'S. IF NO SPEC'S ARE AVAIL, USE FOLLOWING: 1.1. GRAVEL: STANDARD BED AND BACKFILL MATL SHOULD BE A NATURALLY ROUNDED AGGREGATE, CLEAN AND FREE-FLOWING, WITH PARTICLE SIZES NOT LESS THAN 18" NOR MORE THAN 3 4" IN DIAM AND CONTAINING NO MORE THAN 5% (VOL) FINES PASSING #8 SIEVE, COMMONLY KNOWN AS ASTM C-33 PEA GRAVEL. 1.2. STONE OR GRAVEL CRUSHINGS: CRUSHINGS WITH ANGULAR PARTICLE SIZE NOT LESS THAN 18" OR MORE THAN 12" IN DIAM, WASHED AND FREE FLOWING AND CONTAINING NO MORE THAN 5% (VOL) FINES PASSING THROUGH A #8 SIEVE IS ACCEPTABLE AS AN ALT MATL. THIS MATERIAL MUST MEET ASTM C-33 PARA 9.1 RQMNTS LIMITS ON FINES CONTENT AND FOR SOUNDNESS AND QUALITY. 1.3. CAUTION: IN FREEZING CONDITIONS, BACKFILL MUST BE DRY AND FREE OF ICE. DO NOT USE OTHER BACKFILL MATERIALS. DO NOT ALLOW BACKFILL MATERIAL TO INTERMIX WITH AN EXCAVATED SOIL AT THE SITE. 2. DRY GRAVEL DENSITY MUST BE MIN OF 95 LBS PER CUBIC FOOT. 22 2 S E P 2 0 2 1 1 A G A D D E D F R E E A I R , R E V I S E D P V M N T C U R B I N G L E G E N D 3/25/24 08 N O V 2 0 2 1 2 A G R E V P E R P E E R R E V I E W & C I T Y E N G R C M T S ( S L E E V E W A T E R L I N E ) 30 N O V 2 0 2 1 3 A G N O C H A N G E T O F U E L S Y S T E M S , M I N O R C H A N G E S T O M A T C H O T H E R S H E E T S 24 M A R 2 0 2 4 4 A G N O C H A N G E T O F U E L S Y S , M I N O R S I D E W A L K C H A N G E P E R M A D O T C M T S ULR 1 2 3 4 8756LC 161514911 12 1310 17 18 3'-3" 19 MAT REINF AT SUMP NOT TO SCALE FUEL PIPING TRENCH NOT TO SCALE SCALE PROJECT ADDRESS SHEETDWG FILE DETAILS DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. TANK & PIPING TK-2.0 AS NOTED SALEM, MA 342 HIGHLAND AVE TBD-021-01 SAL2 A.L. PRIME SITE # TBD 24 M A Y 2 0 2 1 0 A G O R I G I N D A T E O F D R A W I N G 23 OVERFILL DEVICE NOT TO SCALE VENT RISERS NOT TO SCALE DISPENSER SUMP NOT TO SCALE FUEL PIPING ENTRY NOT TO SCALE TANK SUMP NOT TO SCALE TANK FILL & VAPOR FITTINGS NOT TO SCALE SW PIPE OR CONDUIT ENTRY NOT TO SCALE TANK ELEVATIONS NOT TO SCALE 05/24/21 1'-0" 1:50 SLO P E SLOPE 1:50 SLOPE 1:50 SLOPE 1:12 to 1 : 2 0 1:50 SLOPE 1:5 0 SLO P E ACCESSIBLE VAN ACCESSIBLE WALLSTORE S I D E W A L K E D G E SANITARY MH NOT TO SCALE SECTION THRU FUEL ISLAND NOT TO SCALE CLEAN-OUT NOT TO SCALE ASPHALT PAVEMENT NOT TO SCALE U-SHAPE BOLLARD NOT TO SCALE CONCRETE PAVEMENT JOINTS NOT TO SCALE UTILITY PIPE TRENCH NOT TO SCALE BUILDING SIDEWALK NOT TO SCALE SIDEWALK ADA PARALLEL CURB RAMP NOT TO SCALE ADA PARKING SIGNAGE NOT TO SCALE ADA PARKING PAVEMENT MARKING NOT TO SCALE CURBING NOT TO SCALE SCALE PROJECT ADDRESS SHEETDWG FILE DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. SITE DETAILS 1 SD-1.0AS NOTED SALEM, MA 342 HIGHLAND AVE TBD-021-01 SAL2 A.L. PRIME SITE # TBD 24 M A Y 2 0 2 1 0 A G O R I G I N D A T E O F D R A W I N G 24 3/25/24 SCREENED TRASH ENCLOSURE AND TYP PRIVACY FENCE (CEDAR) NOT TO SCALE BIKE RACK NOT TO SCALE 20 J U L Y 2 0 2 1 1 A G A D D E D B I K E R A C K , C H A N G E D F E N C I N G T O C E D A R 08 N O V 2 0 2 1 2 A G R E V I S E D W A L L D E T A I L SANITARY SVC TAP NOT TO SCALE 30 N O V 2 0 2 1 3 A G A D D E D S A N I T A R Y C O N N E C T I O N D E T A I L DOMESTIC SVC TAP NOT TO SCALE (IN UNPAVED LANDSCAPE, IF NECESSARY) NOTE: DETAILS ON THIS SHEET FOR ON SITE WORK ONLY, REFER TO CURB CUT PLANS AND MA DOT SPECIFICATIONS & APPROVAL CONDITIONS, AND SALEM ENGRG & DPW SPECIFICATIONS FOR ALL WORK OUTSIDE PROPERTY AND IN R.O.W. ALONG HIGHLAND AND BARCELONA AVENUES 24 M A R 2 0 2 4 4 A G R E V P E R M A D O T R E V I E W C M T S Top view illustrating removal of either one Rainstore3 column for a 9" access or four columns for up to a 16" maint port OUTLET OUTLET INLET INLET FLOW FLOW PLAN VIEW SIDE SECTION SCALE PROJECT ADDRESS SHEETDWG FILE DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. SITE DETAILS 2 SD-2.0 AS NOTED SALEM, MA 342 HIGHLAND AVE TBD-021-01 SAL2 A.L. PRIME SITE # TBD 24 M A Y 2 0 2 1 0 A G O R I G I N D A T E O F D R A W I N G 25 INFILTRATION SYSTEM (TYP) NOT TO SCALE 3/25/24 STORMWATER MFGD STC 450i TREATMENT STRUCTURE NOT TO SCALE INF SYS INSP PORT NOT TO SCALE STRAW WATTLE SEDIMENT BARRIER NOT TO SCALE DEEP SUMP CB (TYP) NOT TO SCALE DRAIN BASIN (TYP) NOT TO SCALE CONST ENTRANCE NOT TO SCALE CB INLET PROTECTION NOT TO SCALE OIL/GRIT CHAMBER NOT TO SCALE 08 N O V 2 0 2 1 1 A G R E V I S I O N S P E R P E E R R E V I E W C M T S ROOF DRAIN LEADER NOT TO SCALE SW INF SYS SCHEMATIC NO SCALE 30 N O V 2 0 2 1 2 A G R E V I S I O N S P E R P E E R R E V I E W C M T S 24 M A R 2 0 2 4 3 A G R E V P E R M A D O T C M T S - C H A N G E D D R I V E W A Y C B s T O T R E N C H D R A I N S DRIVEWAY TRENCH DRAINS NO SCALE 24 M A R 2 0 2 4 - 5 - A G - A D J S I D E W A L K A T C O R N E R , N O C H A N G E S T O L A N D S C A P E L A Y O U T 36+0 36+50 37+0 37+50 SH L O 36+50 36+00 37+00 37+50 HI G H L A N D A V E N U E UP 124 126 128 13 0 12 2 120 125 124 12 3 1 2 6 . 6 5 x 12 8 129 124 1 2 5 1 2 7 12 8 118 130 129 1 2 9 1 2 7 128 127 1 2 6 1 2 5 123 125 124 128 127 126 1 2 7 1 2 6 . 6 5 x x 123 119 UP 1 3 1 . 2 9 x 1 3 1 . 2 8 x 1 3 0 . 5 9 x 1 3 0 . 7 0 x 1 3 1 . 7 5 x 1 3 1 . 7 8 x 1 2 8 . 8 5 x 1 3 0 . 6 2 x 1 2 5 . 0 9 t c 1 2 4 . 5 9 b c x 1 2 5 . 1 7 x 1 2 4 . 9 3 1 2 4 . 9 8 xx x 12 6 . 9 0 124.3 7 t c 123.9 5 b c x 1 2 4 . 5 7 x 1 2 3 . 9 7 x 1 2 4 . 0 1 x 12 4 . 0 1 x x 124.4 8 t c 123.9 8 b c 1 2 4 . 9 8 x 12 5 . 5 0 xx 126.8 2 t c 126.3 2 b c x 12 5 . 4 5 x 1 2 5 . 5 0 126.5 1 t c 126.0 1 b c x 12 6 . 5 9 x 1 2 4 . 8 1 x 1 2 4 x 1 2 5 . 5 0 1 2 5 . 2 5 x 1 2 4 . 1 1 36+50 36+00 37+00 37+50 LAYOUT OF PROPOSED SITE GRADING SEE GRAPHIC SCALE SCALE PROJECT ADDRESS SHEETDWG FILE AT R.O.W. DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. C-2.1AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 23 M A R 2 0 2 4 0 A G O R I G I N A L D R A W I N G D A T E 27 3/25/24 CROSS SECTIONS OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW OHW 54 . 6 3 ' 74 . 2 0 ' 64 . 3 1 ' 54 . 3 4 ' 54 . 3 9 ' 64 . 2 9 ' 63 . 7 7 ' 54 . 9 5 ' 54 . 5 4 ' 54 . 7 7 ' 54 . 8 0 ' 54 . 6 7 ' +66.86 +03.03 +24.13 +34.12 +54.50 +64.51 +91.27 +11.66 REMOVE EXISTING CURB SAWCUT REM PROP VGCREM RET RET REM REM SAWCUT SAWCUT RET RET RET P R O P H M A W A L K PROP VGC RET RET REM PROP VGC PROP BCC PROP ADA PANEL PROP CURB RAMP REPAVE ABUTTER HMA DRIVEWAY PROP CC SIDEWALK PROP VGC PROP CC SIDEWALK PROP ADA PANEL PROP CURB RAMP 15.00' 6.50' PROP LOAM AND SEED PROP R1-1 PROP VGC PCR 1 PCR 2 20 SCALE: 1" = 20' 0 50 100 DATENO. DRAWING NAME: REVISION: DATE: PROJECT NUMBER: SCALE: DRAWING NUMBER: DRAWN BY: PROJECT NAME: PREPARED BY: 0 DAVID A. CHAPPELL 1 2 3 4 5 6 7 1"=20'04/11/2024 CURB CUT PLAN PKB CC1 = PROPOSED CURB CUT APPLICANT: 06/15/23 FOR REVIEW OWNER: PROPOSED GAS STATION & C-STORE #342 HIGHLAND AVE. CITY OF SALEM ESSEX COUNTY MASSACHUSETTS A.L. PRIME ENERGY CONSULTANT, INC. 6'-0" 6" 2'-0" 1.5" HOT MIX ASPHALT SUPERPAVE SURFACE COURSE 9.5 (SSC-9.5) 2.5" HOT MIX ASPHALT SUPERPAVE INTERMEDIATE COURSE 12.5 (SIC-12.5) 12" GRAVEL BORROW TYPE B N T S NOTE: ASPHALT EMULSION FOR TACK COAT SHALL BE SPRAY APPLIED FOR DOUBLE OVERLAP COVERAGE AT 0.07 GAL/SY OVER MILLED SURFACES AND 0.05 GAL/SY OVER SMOOTH SURFACES. NOTE: 1. THIS PROCEDURE IS APPLICABLE ONLY IF CURB IS TO BE SET AFTER BASE COURSE IS IN PLACE PRIOR TO BINDER AND TOP PLACEMENT. 2. CUT NEAT LINE 6" FROM CURB LINE AND REMOVE BASE AND GRAVEL. REPLACE WITH CEMENT CONCRETE. 3. ANY DESIGNATED CEMENT CONCRETE THAT IS ACCEPTABLE UNDER SECTION M4 OF THE STANDARD SPECIFICATIONS MAY BE USED: ALL TEST REQUIREMENTS ARE WAIVED. HOT MIX ASPHALT SHALL NOT BE USED AS A SUBSTITUTE. TREATMENT VARIES 6" REVEAL EXCEPT ON BRIDGES VERTICAL CURB CEMENT CONCRETE LIMITSGRAVEL SUBBASE BASE COURSE CUT LINE HMA BINDER COURSE HMA SURFACE COURSE 6" 6"6" A.L. PRIME ENERGY CONSULTANT, INC. N 07/31/23 FOR REVIEW ROADWAY PROFILE GRADE *HIGH SIDE TRANSITION LENGTH %ENGLISH UNITS =0%6'-6" >0% TO 1%7'-8" 9'-0" 11'-0" 14'-0" 15'-0" MAX >1% TO 2% >2% TO 3% >3% TO 4% >4% TO 5% NOTE: *BASED ON A DESIGN SLOPE OF 7.5% AND A REVEAL OF 6" 1.5" HMA SURFACE COURSE 1.5%2.5" HMA INTERMEDIATE COURSE 12" GRAVEL BORROW TYPE B DRIVEWAY* ROADWAY 12" BASE COURSE 1.75" SUPERPAVE SURFACE COURSE* 2.25" SUPERPAVE INTERMEDIATE COURSE* 3.5" SUPERPAVE BASE COURSE* 1" LIP MATCH EXISTING CROSS SLOPE *NOTE: 1. PAVEMENT THICKNESS SHOULD FOLLOW THE EXISTING PAVEMENT STRUCTURE OF ROUTE 107 04/23/24 REV 1 28 -1 . 4 9 % -1 . 5 9 % -1 . 6 7 % -4.85% -2.35% -5 . 0 1 % -4 . 9 1 % -1 . 6 8 % -5 . 1 1 % -2.77% -2.69%-2.27%-3.26% -1 . 3 3 % -4 . 8 7 % -5 . 0 0 % -1 . 5 1 % -2.74% -2.59% -3.91% -1 . 4 9 % -1 . 4 9 % -7.04%-2.91% -2.90% -2.99% -1 . 6 7 % -5 . 0 0 % -1 . 3 3 % -5 . 0 1 % -4 . 6 8 % -1 . 6 7 % -2.44% -2.41% -1.61% -0.47% -1.60%-2.81%-7.47% -1 . 5 4 % 1. 5 7 % -0 . 8 0 % -1 . 4 8 % 7.5%* MAX SIDEWALK WHEEL CHAIR RAMP LIMITS OF WCR CEMENT CONCRETE OR HOT MIX ASPHALT LOW SIDE TRANSITION 7.5%* MAX WHEELCHAIR RAMP (3 ' - 0 " M I N . ) OPENING WIDTH "LEVEL ENTRANCE" 1.5% SLOPE FOR DRAINAGE 1.5%* HIGH SIDE TRANSITION CR O S S W A L K (3 ' - 0 " M I N . ) LIMITS OF WCR CEMENT CONCRETE OR HOT MIX ASPHALT DETECTABLE WARNING PANEL (E 107.6.5) ON LEVEL LANDING FOR LEVEL LANDINGS >= 5 FT DEPTH SIDEWALK FOUNDATION SECTION A-A DETECTABLE WARNING PANEL (SEE E 107.6.5) ON LEVEL LANDING 8" CC = 4" LEVEL LANDING DEPTH >= 5 FT 7.5%* RAMP 1.5%* ROADWAY SIDEWALK FOUNDATION DETECTABLE WARNING PANEL (SEE E 107.6.5) AT BOTTOM OF RAMP 8" CC = 4" LEVEL LANDING DEPTH < 5 FT 7.5%* RAMP 1.5%* ROADWAY CROSSWALK MARKINGS MUTCD COMPLIANT RAMP REFERENCE POINT AA1.5%* DEPTH OF LEVEL LANDING DEPTH OF LEVEL LANDING DE P T H F R O M GU T T E R T O BA C K O F WA L K DETECTABLE WARNING PANEL (E 107.6.5) AT BASE OF RAMP FOR LEVEL LANDINGS < 5 FT DEPTH LE V E L LE V E L 6" CURB REVEAL (TYP.) ROADWAY DOWNGRADE (-) SIDE WALK DATENO. DRAWING NAME: REVISION: DATE: PROJECT NUMBER: SCALE: DRAWING NUMBER: DRAWN BY: PROJECT NAME: PREPARED BY: 0 DAVID A. CHAPPELL 1 2 3 4 5 6 7 1"=8'04/11/24 DRIVEWAY GRADING AND PCR DETAILS PKB CC2 APPLICANT: 06/15/2023 FOR REVIEW OWNER: PROPOSED GAS STATION & C-STORE #342 HIGHLAND AVE. CITY OF SALEM ESSEX COUNTY MASSACHUSETTS A.L. PRIME ENERGY CONSULTANT, INC. PROPOSED DRIVEWAY GRADING SCALE 1" = 8' A.L. PRIME ENERGY CONSULTANT, INC. N 8" COMPACTED GRAVEL VARIES 4" - 4,000 PSI 3 4 INCH 610 CONCRETE MIX COMPACTED SUBGRADE 8 SCALE: 1" = 8' 0 20 40 07/31/2023 FOR REVIEW PROPOSED PCR SCALE N/A 04/23/2024 REV 1 29 HIGHLAND AVENUE (ROUTE 107) R C E L O N A A V E N U E FO R E S T R I V E R 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 MINIMUM 12' WIDE ONE WAY TRAVEL LANE PROP WATER SERVICE DISCONNECT PROP WATER SERVICE DISCONNECT 150 FT 30 SCALE: 1" = 30' 060120 DATENO. DRAWING NAME: REVISION: DATE: PROJECT NUMBER: SCALE: DRAWING NUMBER: DRAWN BY: PROJECT NAME: PREPARED BY: 0 DAVID A. CHAPPELL 1 2 3 4 5 6 7 1"=30'04/23/2024 TRAFFIC MANAGEMENT PLAN WDF TMP1 APPLICANT: 10/20/23 FOR REVIEW OWNER: PROPOSED GAS STATION & C-STORE #342 HIGHLAND AVE. CITY OF SALEM ESSEX COUNTY MASSACHUSETTS A.L. PRIME ENERGY CONSULTANT, INC. A.L. PRIME ENERGY CONSULTANT, INC. 04/23/24 FOR REVIEW  HIGHLAND AVENUE (ROUTE 107) R C E L O N A A V E N U E FO R E S T R I V E R 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 MINIMUM 12' WIDE ONE WAY TRAVEL LANE PROP WATER SERVICE DISCONNECT PROP WATER SERVICE DISCONNECT PROP SEWER SERVICE DISCONNECT 90 FT 150 FT 30 SCALE: 1" = 30' 060120 DATENO. DRAWING NAME: REVISION: DATE: PROJECT NUMBER: SCALE: DRAWING NUMBER: DRAWN BY: PROJECT NAME: PREPARED BY: 0 DAVID A. CHAPPELL 1 2 3 4 5 6 7 1"=30'04/23/2024 TRAFFIC MANAGEMENT PLAN WDF TMP2 APPLICANT: 10/20/23 FOR REVIEW OWNER: PROPOSED GAS STATION & C-STORE #342 HIGHLAND AVE. CITY OF SALEM ESSEX COUNTY MASSACHUSETTS A.L. PRIME ENERGY CONSULTANT, INC. A.L. PRIME ENERGY CONSULTANT, INC. 04/23/24 FOR REVIEW  HIGHLAND AVENUE (ROUTE 107) N A A V E N U E FO R E S T R I V E R 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 MINIMUM 12' WIDE ONE WAY TRAVEL LANE 90 FT 150 FT TEMPORARY PEDESTRIAN RAMP AND HANDRAIL INSTALLED PARALLEL TO THE SIDEWALK WITHIN THE EXIST ROADWAY (TYP.) 5'X5' TURNING AREA 5' MIN. PEDESTRIAN PATH 4' MIN. CLEARANCE FOR PEDESTRIAN BARRICADE DETECTABLE WARNING PANEL (TYP.) ROADWAY TO REMAIN OPEN DURING CONSTRUCTION 2' MIN. CLEARANCE FOR PEDESTRIAN BARRICADE 30 SCALE: 1" = 30' 060120 DATENO. DRAWING NAME: REVISION: DATE: PROJECT NUMBER: SCALE: DRAWING NUMBER: DRAWN BY: PROJECT NAME: PREPARED BY: 0 DAVID A. CHAPPELL 1 2 3 4 5 6 7 1"=30'04/23/2024 TRAFFIC MANAGEMENT PLAN WDF TMP3 APPLICANT: 10/20/23 FOR REVIEW OWNER: PROPOSED GAS STATION & C-STORE #342 HIGHLAND AVE. CITY OF SALEM ESSEX COUNTY MASSACHUSETTS A.L. PRIME ENERGY CONSULTANT, INC. A.L. PRIME ENERGY CONSULTANT, INC. 04/23/24 FOR REVIEW  HIGHLAND AVENUE (ROUTE 107) B A R C E L O N A A V E N U E FO R E S T R I V E R 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 1*9 PROP WATER SERVICE DISCONNECT PROP WATER SERVICE DISCONNECT PROP SEWER SERVICE DISCONNECT TYPICAL EXISTING PIPE TRENCH DETAIL UNDER ROADWAY SCALE: NONE DIA. 1/ 4 D 6" MI N . 12 " MI N . C R U S H E D S T O N E G R A V E L B O R R O W VA R I E S IN EARTH IN ROCK G R A V E L B O R R O W P E R M A N E N T T R E N C H P A T C H TRENCH PAY LIMIT D + 3' 12" (TYP.) ȭ TRENCH BA C K F I L L W I T H I N - S I T U WI T H O R D I N A R Y B O R R O A N D C O M P A C T E D I N 8 " L A FULL DEPTH SAWCUT EDGES APPLY HMA JT SEALANT (TYP.) 30 SCALE: 1" = 30' 060120 DATENO. DRAWING NAME: REVISION: DATE: PROJECT NUMBER: SCALE: DRAWING NUMBER: DRAWN BY: PROJECT NAME: PREPARED BY: 0 DAVID A. CHAPPELL 1 2 3 4 5 6 7 1"=30'04/23/2024 UTILITY DISCONNECT PLANS WDF UT-1 APPLICANT: 10/20/23 FOR REVIEW OWNER: PROPOSED GAS STATION & C-STORE #342 HIGHLAND AVE. CITY OF SALEM ESSEX COUNTY MASSACHUSETTS A.L. PRIME ENERGY CONSULTANT, INC. A.L. PRIME ENERGY CONSULTANT, INC. PROPOSED FULL DEPTH PAVEMENT SURFACE: 2.0" SUPERPAVE SURFACE COURSE 12.5 (SSC - 12.5) OVER ASPHALT EMULSION FOR TACK COAT (RS-1h) OVER INTERMEDIATE: 2.25" SUPERPAVE INTERMEDIATE COURSE 19.0 (SIC - 19.0) OVER ASPHALT EMULSION FOR TACK COAT (RS-1h) OVER BASE: 4" SUPERPAVE BASE COURSE 37.5 (SBC - 37.5) OVER SUBBASE: 4" DENSE GRADED CRUSHED STONE OVER 8" GRAVEL, TYPE b 04/23/24 FOR REVIEW *ALL NEW WATER, SANITARY, AND ELECTRIC UTILITY CONNECTIONS ARE PROPOSED VIA BARCELONA AVENUE  HIGHLAND AVENUE BA R C E L O N A A V E N U E A F1 B C E D F2 F4 F3 F5 342 ATM C B E E3 E2E1.9 10000 REGULAR UNLEADED E4 .9 10000 .9 10000 REGULAR UNLEADED DIESEL A ATM COLD DRINKS F E4 SIGN LOCATION PLAN SIGNAGE SOUTH ELEVATION (FRONT) SEE GRAPHIC SCALE PROPOSED SIGNAGE TYPEKEY 6'-8" x 3'-6" SIZE AREA (sf)INTERNALLY 110.30 9'-2" x 3'-6" (irreg)19.09 TOTAL PROPOSED SITE SIGNAGE: 306.73 sf FREESTANDING B A C 8'-8" x 3'-6"30.34WALL (BLDG) DIST TO 11'-0" 15'-8" BOTTOM DIST TO TOP 14'-6" 19'-2" 7'-0"25'-0" Y ILLUMINATED CMTS LED PRICES Y Y F1 F2 F3 Allowed Signage 486sf (Calc 243 lf frontage x 2 sf lf = 486 sf) Allowed Signage 130sf (B2 zone with frontage exceeding 200') WALL (CANOPY) TOTAL PROPOSED FREESTANDING SIGNAGE: 110.30 sf WALL (BLDG) D WALL (BLDG) WALL (CANOPY) WALL (CANOPY) GAS CANOPY SOUTH ELEVATION WALL SEE GRAPHIC SCALE SIGN SEE GRAPHIC SCALE DIESEL CANOPY WALL SEE GRAPHIC SCALE GAS CANOPY NORTH ELEV WALL SEE GRAPHIC SCALE 7'-0" x 4'-0" 6'-10" x 2'-7" 28.00 16'-9" 19'-4" Y Y Y Y 17.50 4'-6" 8'-6" 16'-9" 19'-4" 16'-9" 19'-4" 6'-10" x 2'-7" 6'-10" x 2'-7" 17.50 17.50 SCALE PROJECT ADDRESS SHEETDWG FILE DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. SG-1 AS NOTED SALEM, MA 342 HIGHLAND AVENUE TBD-021-01 SALEM A.L. PRIME SITE # tbd 24 M A Y 2 0 2 1 0 A G O R I G I N D A T E O F D R A W I N G 34 03/25/24 WALL (CANOPY)5'-7-3/4" x 3'-3"16'-4" 19'-7" 18.43 F4 Y LED PRICES APPLICANT IS NOT SEEKING ANY WAIVER OR RELIEF FOR SIGNAGE AND WILL APPLY FOR SIGNAGE PERMITS SEPARATELY. THIS PLAN FOR BOARD INFORMATION, IT IS INTENDED AND BELIEVED THAT THE PROPOSED SIGNAGE IS AS ALLOWED BY RIGHT. FREESTANDING EAST ELEVATION SEE GRAPHIC SCALE GAS CANOPY NORTH ELEVATION WALL SEE GRAPHIC SCALE 6'-0" x 14'-6" E WALL (BLDG)Y WALL (CANOPY)16'-9" 19'-4" 6'-10" x 2'-7"17.50F5 Y 6'-10" x 2'-7"11'-2" 13'-9" 17.50 02 S E P 2 0 2 1 1 A G S M A L L E R P R I C E S I G N P E R D R B C M T S 24 M A R 2 0 2 4 2 A G N O C H A N G E T O S I G N A G E , O N L Y A D J S I D E W A L K P E R M A D O T C M T S NOT TO SCALE NOZZLE AIM POINTS AIMING POINT NOZZLE LOCATION 15 ' M A X D E T E C T O R H T 7' M I N - 1 1 ' M A X N O Z Z L E H T 22 2 5 23 7 6 3 4 15 16 POSITIVE LIMITING BARRIER (PLB) NOT TO SCALE THE POSITIVE LIMITING BARRIER TO BE 5 CONTINUOUS SQUARE OR "V" GROOVES 3/4" WIDE BY 3/4" DEEP, 4-3/4" ON CENTER W/ CROSS INTERCONNECTING GROOVES SPACED AT 12" MIN TO 48" MAX ON CENTER. THE OUTSIDE GROOVE TO BE AT LIMITS OF HAZARD PROTECTION AREA AND THE POTENTIAL SPILL AREA TO BE WITHIN THIS PROTECTED AREA. SELF-SERVICE SIGN NOT TO SCALE SELF SERVICE ISLAND 12"x16" WARNING SIGN SHALL BE CONSPICUOUSLY POSTED ON BOTH ENDS OF THE DISPENSER. LETTERING SIZE AND LOCATION SHALL BE AS SHOWN ABOVE. IT IS UNLAWFUL AND DANGEROUS TO DISPENSE GASOLINE INTO UNAPPROVED CONTAINERS. NO FILLING OF PORTABLE CONTAINERS IN OR ON A MOTOR VEHICLE OR TRAILER. PLACE CONTAINER ON GROUND BEFORE FILLING. BY ORDER OF THE STATE FIRE MARSHAL NO SMOKING - STOP MOTOR WARNING 9. ON PARTIAL (SPLIT SERVICE) SELF-SERVICE FACILITIES AN ADDITIONAL SWITCH, WHICH WILL DISCONNECT POWER TO THE SELF-SERVE ISLAND AND ACTIVATE THE SUPPRESSION SYS SHALL BE INSTALLED ON THE FULL SERVE ISLAND. 10. WARNING SIGNS SHALL BE CONSPICUOUSLY POSTED ON BOTH ENDS OF THE DISPENSER AND SHALL INCORPORATE STATE REQD LANGUAGE (SEE SIGN DETAIL) 11. THE CONCRETE PAD SURROUNDING THE DISPENSING ISLAND SHALL BE INSTALLED AS LEVEL AS POSSIBLE. THE POSITIVE LIMITING BARRIER (PLB)(GROOVES) SHALL BE INSTALLED IN THIS PAD WITH OUTER GROOVE LOCATED NO FURTHER THAN THE PROTECTED HAZARD AREA DEFINED BY THE FIRE SUPPRESSION SYSTEM DESIGN. NOZZLES SHALL NOT EXTEND BEYOND THE PLB AT THE AVERAGE FUELING HEIGHT OF 3 TO 4 FEET. 12. A MEANS TO INSTANTLY DISCONNECT THE POWER TO ALL DISPENSERS AND ACTIVATE THE SUPPRESSION SYS SHALL BE CONSPICUOUSLY MARKED AND LOCATED AT THE CONTROL CONSOLE. 13. THE USE OF AUTOMATIC CREDIT READING DEVICES ARE PERMITTED PROVIDED THAT THEY ARE INDICATED ON THE PLANS & COMPLY WITH THE REQMNTS OF 527 CMR 1.00 SECTION 42.7.4.5(1)(k). 14. 225° (MAX) ELECTRIC THERMOSTAT DETECTORS SHALL BE INSTALLED ON 15 FOOT (MAX) CENTERS IN A SINGLE LINE OVER THE CENTER OF THE ISLAND FOR ISLANDS UP TO 6 FT WIDE. FOR WIDER ISLANDS 2 ROWS OF DETECTORS SHALL BE LOCATED 1 FT IN FROM EA CURB. IF A CANOPY IS PROVIDED DETECTORS SHALL BE LOCATED ON THE UNDERSIDE OF THE CANOPY. IF THERE IS NO CANOPY, THE DETECTOR(S) SHALL BE MOUNTED TO THE UNDERSIDE OF AN 18"x18"x2" HEAT COLLECTOR, WHICH SHALL BE LOCATED NO HIGHER THAN THE NOZZLES. 14. FIRE EXTINGUISHERS SHALL BE A MINIMUM 40BC HIGH FLOW. 15. RAISING OR LOWERING OF AN EXSTG SUPPRESSION SYS OR TEMP RELOCATION OF CONTROL CONSOLE MAY BE COMPLETED ONLY AFTER WRITTEN NOTIFICATION TO AND WRITTEN ACKNOWLEDGEMENT FROM THE HEAD OF THE LOCAL FD AND STATE FIRE MARSHAL OFFICE. 16. CHANGING HEAT DETECTORS TO THOSE SPECIFIED IN CURRENT GUIDELINES, OR REPLACING DISPENSING NOZZLES WITH "HOLD OPEN" NOZZLES SHALL NOT REQUIRE NOTICE OR APPROVAL FROM STATE FIRE MARSHAL OFFICE. 17. A COMPLETE RESUBMITTAL IN ACCORDANCE WITH THEN CURRENT SELF-SERVICE GUIDELINES IS REQUIRED IN THE FOLLOWING CASES: 17.1. REPLACEMENT OF THE FIRE SUPPRESSION SYSTEM 17.2. CHANGE IN METHOD OF DISPENSING (I.E.- CHANGING FROM SPD TO MPD DISPENSERS) 17.3. REPLACEMENT OR RECONSTRUCTION OF THE DISPENSING ISLAND 17.4. MATERIAL CHANGE IN ENVIRONMENTAL CONDITIONS OR HAZARD AREA (I.E.- CHANGE THAT IMPACTS ATTENDANT ABILITY TO OBSERVE THE FUELING OPERATION) 18. THE CONTRACTOR SHALL VISIT THE SITE AND BE RESPONSIBLE FOR FIELD CONFIRMATION OF ALL ITEMS ON THE PLAN AND SHALL NOTIFY THE DESIGNER IN WRITING OF ANY DISCREPANCY BEFORE PROCEEDING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE INSTALLATION OF THE ENTIRE SYSTEM AND SHALL COMPLY WITH THE REGULATIONS SET FORTH BY THE PREVAILING MASSACHUSETTS CODE AND THE EQUIPMENT MANUFACTURER SPECIFICATIONS. 1. REFER TO THE MOST CURRENT MASS DEPT OF FIRE SVCS DIV OF FIRE SAFETY "GUIDELINES FOR SELF-SERVICE MOTOR FUEL FACILITY GUIDELINES", 527 CMR 1.00 FIRE REGS, NFPA 17, & THE SYS MFGR UL LISTING, SYS MANUALS, & LOCAL AND STATE APPROVALS FOR THIS SYSTEM. 2. ALL MA SELF SERVICE DISPENSING AREAS OPEN TO THE PUBLIC SHALL BE EQUIPPED WITH A LISTED UL-1254 COMPLIANT PRE-ENGINEERED DRY CHEMICAL EXTINGUISHING SYSTEM, INCLUDING END OF ISLAND PROTECTION; AND DESIGNED & INSTALLED TO PROTECT THE ENTIRE SPILL & HAZARD AREA. 3. STATE REQUIRED PLAN STATEMENTS: 3.1. SELF-SERVE EXTINGUISHING SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH STATE FIRE MARSHAL APPROVED PLANS. 3.2. ALL EXTINGUISHING SYSTEMS, DISPENSING SYSTEMS, AND CONTROL EQUIPMENT SHALL BE UNDERWRITERS LABORATORY (UL) LISTED. 3.3. CREDIT CARD READING DEVICES ARE PROPOSED AT THIS LOCATION AND ARE SUBJECT TO 527 CMR 1.00 SECTION 42.7.4.5 (1)(K): 3.3.1. EA SALE SHALL BE INDIVIDUALLY AUTHORIZED BY THE SELF-SERVICE ATTENDANT 3.3.2. THE AUTOMATIC CREDIT CARD READING DEVICE SHALL NOT BE USED AS PHYSICAL AUTHORIZATION FOR THE DISPENSING OF MOTOR FUEL 3.3.3. THE AUTOMATIC CREDIT CARD READING DEVISES ARE INCLUDED ON PLANS SUBMITTED TO AND APPROVED BY THE STATE FIRE MARSHAL (SEE NOTES AND LEGEND) 3.4. FAILURE TO CONSTRUCT, INSTALL, OR MAINTAIN ANY EQUIPMENT, DEVICES, SYSTEM, OR PROCEDURE INDICATED ON THE APPROVED PLANS SHALL BE CAUSE FOR THE REVOCATION OF THIS APPROVAL 3.5. PLANS APPROVED BY THE MARSHAL ARE ON THE CONDITION THAT THEY COMPLY IN ALL RESPECTS TO 527 CMR 1.00. ANY OMISSIONS OR ERRORS ON THE PLANS DO NOT RELIEVE THE APPLICANT OR INSTALLER FROM COMPLYING WITH ALL APPLICABLE REQUIREMENTS OF 527 CMR 1.00. 3.6. STATE FIRE MARSHAL APPROVAL OF PLANS TO CONSTRUCT/RENOVATE A SELF-SERVICE FACILITY BECOMES NULL AND VOID ONE YEAR FROM THE DATE OF THE APPROVAL. 4. ALL FIRE SUPPRESSION SYSTEMS SHALL BE INSTALLED & MAINTAINED BY COMPANIES & PERSONS HOLDING REQ'D CERTIFICATES OF COMPETENCY & REGISTRATION ISSUED BY THE MARSHAL. 5. FIRE SUPPRESSION SYS SHALL BE INSTALLED & MAINTAINED IN ACCORDANCE WITH THE PROVISIONS OF NFPA 17 (SEE 527 CMR 1.00 CH 2 FOR CURRENT EDITION), AND THE MFGR'S INSTALLATION & MAINTENANCE MANUAL. 6. CLOSED CIRCUIT TV (CCTV) COVERAGE IS REQUIRED ON ALL FUELING POSITIONS. CCTV MONITORS SHALL DISPLAY ALL CAMERA ANGLES SIMULTANEOUSLY ON THE SCREEN WITH A MIN FRAME OF 5" BY 6.5" PER CAMERA. CCTV SHALL DISPLAY IMAGES IN COLOR. 7. AN INTERCOM SYS IS REQ'D BETWEEN THE CONTROL CONSOLE AND DISPENSING ISLAND. 8. THE CONTROL CONSOLE WILL BE LOCATED IN DIRECT LINE OF SIGHT AND WITHIN 200 FEET OF THE MOST REMOTE DISPENSER. DISTANCES GREATER THAN 200 FT MAY BE APPROVED AT SOLE DISCRETION OF THE STATE FIRE MARSHAL. 13 5 22 3 4 2 7 1 14 23 15 16 5 22 3 4 2 17 7 1 14 23 15 6 13 5 PROTECTED AREA - (1 ea) System Protecting 72.5' x 26.0' (1 ea) System Protecting 50.0' x 26.0' (1ea) Systems Protecting 33.5 x 26.0' 75# CYLINDERS - TOTAL OF 13ea 75# CYLINDERS 35# CYLINDERS - TOTAL OF 2ea 35# CYLINDERS NOZZLES - 112ea TOTAL NOZZLES1 10 16 17 7 21 20 18 24 9 19 19 8 HIGHLAND AVE PL = 136.33' BA R C E L O N A A V E 12K 6K 6K PL = 243.51' PL = 1 6 3 . 7 4 ' PL = 2 0 4 . 8 7 ' 1 10 16 11 12 12K 4K 19 1 1 1 1 24 24 PL = 2 6 . 6 1 ' PL = 119.41' SI G N 17 FIRE SUPPRESSION SITE LAYOUT REFERENCE: THIS PLAN IS NOT A SURVEY NOR INTENDED TO PROVIDE ANY SITE INFO OTHER THAN GENERAL ARRANGEMENT APPROXIMATION FOR THE SOLE PURPOSE OF FIRE SUPPRESSION SYSTEM RELATED WORK. IT SHOULD NOT BE USED FOR ANY OTHER PURPOSE OR AS A SITE LAYOUT REFERENCE FOR ANY OTHER WORK. ALL SITE IMPROVEMENTS ARE SHOWN PER THE BEST AVAIL INFO AND MUST BE VERIFIED IN THE FIELD, PARTICULARLY ANY EXCAVATION OR WORK THAT MAY AFFECT BURIED UTILITIES. PROPERTY LINES AND OTHER SITE INFO SHOWN ON THIS DRAWING TAKEN FROM EXISTING CONDITIONS PLAN BY EASTERN LAND SURVEY ASSOC, INC., 104 LOWELL ST, PEABODY MA 01960, 04/05/21, SCALE 1"=20' SELF SERVICE THIS BOX RESERVED FOR STATE FIRE MARSHAL OFFICE USE ONLY THIS BOX RESERVED FOR STATE FIRE MARSHAL OFFICE USE ONLY MOTOR FUEL DISPENSER - U/L APPROVED LEGEND 10 23 22 24 19 18 21 20 14 15 17 16 11 13 12 7 8 9 4 5 3 2 1 DRY CHEMICAL CYLINDER OH FSS PIPING - SCHED 40 (DIST & SUPPLY) UL LISTED SYSTEM NOZZLE 225 (MAX) DEGREE AUTO THERMOSTAT PLB - POSITIVE LIMITING BARRIER GROOVES CONTROL CONSOLE EQUIPMENT SELF-SERVICE ATTENDANT LOCATION DISPENSER EMGCY SHUTDOWN SWITCH MANUAL SYSTEM RELEASE SWITCH CCTV CAMERA (AT EA DISPENSER) INTERCOM SPEAKER (AT EA DISPENSER) MA FIRE MARSHAL APPROVED SIGNAGE SAFETY BUMPER OR BOLLARD HAND OPERATED 40BC HI FLOW EXTINGUISHER GLASS DOOR OR WINDOW FOR SIGHT LINE DRIVEWAY FUEL TRANSPORT AT DROP POSITION ATTENDANT SIGHT LINES LIGHTING WITHIN FUELING AREA COLUMN OR LIGHT POLE PARKING SPACES UG MOTOR FUEL STORAGE TANK NOTE: - DISPENSING AREA TO BE AS LEVEL AS POSSIBLE - 6 DISPENSERS & 12 FUELING POSITIONS, INCLUDING DIESEL - ALL DISPENSERS CONTAIN CREDIT CARD READERS THIS BOX RESERVED FOR LOCAL FIRE DEPARTMENT USE THIS BOX RESERVED FOR LOCAL FIRE DEPARTMENT OFFICE USE I, _____________________________, CHIEF OF THE DEPARTMENT OR HIS DESIGNEE, HAVE REVIEWED THE ATTACHED INFORMATION AND HAVE ACKNOWLEDGEMENT THEREOF: CITY/TOWN ____________________________________ DATE _________________________ SYSTEM INFORMATION ATTENDANT 1 SYSTEM MFGRD BY PYRO CHEM, INC. MODEL ATD-35/75 -- MEETS UL-1254 SYSTEM INSTALLER - TO BE DETERMINED INSTALLER MA CERT OF COMPETENCY NUMBER - _____________________ INSTALLER MA CERT OF REGISTRATION NUMBER - ____________________ NEW TO INDUSTRY SELF SERVICE FACILITY GENERAL NOTES 6 NOZZLE AIMING POINT ISLAND END ELEVATION NOT TO SCALE SEE GRAPHIC SCALE THIS COPY: SCALE PROJECT ADDRESS SHEETDWG FILE A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. FSP-1AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 DE S C R I P T I O N RE V BY DA T E 24 M A Y 2 0 2 1 0 A G O R I G I N A L D R A W I N G D A T E ISLAND SIDE ELEVATION - (TYP) NOT TO SCALE NARRATIVE THE PURPOSE OF THIS WORK IS TO INSTALL A DRY CHEMICAL FIRE SUPPRESSION SYS MEETING UL-1254 AT THIS NEW TO INDUSTRY SELF SERVICE MOTOR FUEL FACILITY. THE PROPOSED FACILITY INCLUDES 6 FUEL DISPENSER (12 FUELING POSITIONS) INCLUDING DIESEL AND DEF, ALL DISPENSERS INCLUDE CREDIT CARD READERS. THE ATTENDANT IS LOCATED IN A CONVENIENCE STORE AND LESS THAN 115 FEET FROM THE FURTHEST DISPENSER. PLBs (POSITIVE LIMITING BARRIER GROOVES) WILL BE INSTALLED AROUND THE ENTIRE FUELING AREA. CAMERAS (CCTV) AND SIGNAGE WILL ALSO BE INSTALLED AT EA DISPENSER TO MEET STATE FIRE MARSHAL GUIDELINE REQUIREMENTS. ALL EQUIPMENT WILL BE INSTALLED PER THE MFGR'S PRE-ENGINEERED DESIGN MANUAL. THE SYSTEM WILL PROVIDE BOTH AUTOMATIC AND MANUAL ACTIVATION SWITCHES. THERE WILL BE HIGH TEMP SENSORS INSTALLED IN THE FUEL DISPENSER AREAS. SYSTEM OPERATION, MAINTENANCE, AND TECHNICAL SPECIFICATIONS ARE PER THE MFGR DESIGN MANUAL. GRADES IN FUELING AREAS TO BE AS LEVEL AS POSSIBLE, AVERAGE GRADES FOR THIS SITE APPROX 2.5% - 4% 35 20 J U L 2 0 2 1 1 A G R E V T O M A T C H S I T E P V M N T R E V I S I O N S , N O C H A N G E T O F I R E S U P P S Y S 02 S E P 2 0 2 1 2 A G R E V S I T E P V M N T , N O C H A N G E T O F I R E S U P P S Y S 3/25/24 08 N O V 2 0 2 1 3 A G A D D E D S I D E W A L K , N O C H A N G E T O F I R E S U P P S Y S 30 N O V 2 0 2 1 4 A G R E M O V E D R E T A I N I N G W A L L , N O C H A N G E T O F I R E S U P P S Y S 24 M A R 2 0 2 4 5 A G A D J S I D E W A L K P E R M A D O T C M T S - N O C H A N G E T O S Y S T E M L A Y O U T 7 13 1514 16 17 23 1234 5 5 13 16 PROTECTED AREA - (1 ea) System Protecting 72.5' x 26.0' (1 ea) System Protecting 50.0' x 26.0' (1ea) Systems Protecting 33.5 x 26.0' 75# CYLINDERS - TOTAL OF 13ea 75# CYLINDERS 35# CYLINDERS - TOTAL OF 2ea 35# CYLINDERS NOZZLES - 112ea TOTAL NOZZLES HI TEMP HEAT DETECTORS - 9ea TOTAL HEAT DETECTORS 7 15 14 16 17 23123 4 5 13 FIRE SUPPRESSION SELF SERVICE THIS BOX RESERVED FOR STATE FIRE MARSHAL OFFICE USE ONLY THIS BOX RESERVED FOR STATE FIRE MARSHAL OFFICE USE ONLY MOTOR FUEL DISPENSER - U/L APPROVED LEGEND 10 23 22 24 19 18 21 20 14 15 17 16 11 13 12 7 8 9 4 5 3 2 1 DRY CHEMICAL CYLINDER OH FSS PIPING - SCHED 40 (DIST & SUPPLY) UL LISTED SYSTEM NOZZLE 225 (MAX) DEGREE AUTO THERMOSTAT PLB - POSITIVE LIMITING BARRIER GROOVES CONTROL CONSOLE EQUIPMENT SELF-SERVICE ATTENDANT LOCATION DISPENSER EMGCY SHUTDOWN SWITCH MANUAL SYSTEM RELEASE SWITCH CCTV CAMERA (AT EA DISPENSER) INTERCOM SPEAKER (AT EA DISPENSER) MA FIRE MARSHAL APPROVED SIGNAGE SAFETY BUMPER OR BOLLARD HAND OPERATED 40BC HI FLOW EXTINGUISHER GLASS DOOR OR WINDOW FOR SIGHT LINE DRIVEWAY FUEL TRANSPORT AT DROP POSITION ATTENDANT SIGHT LINES LIGHTING WITHIN FUELING AREA COLUMN OR LIGHT POLE PARKING SPACES UG MOTOR FUEL STORAGE TANK NOTE: - DISPENSING AREA TO BE AS LEVEL AS POSSIBLE - 6 DISPENSERS & 12 FUELING POSITIONS - ALL DISPENSERS CONTAIN CREDIT CARD READERS THIS BOX RESERVED FOR LOCAL FIRE DEPARTMENT USE THIS BOX RESERVED FOR LOCAL FIRE DEPARTMENT OFFICE USE I, _____________________________, CHIEF OF THE DEPARTMENT OR HIS DESIGNEE, HAVE REVIEWED THE ATTACHED INFORMATION AND HAVE ACKNOWLEDGEMENT THEREOF: CITY/TOWN ____________________________________ DATE _________________________ SYSTEM INFORMATION ATTENDANT 1 SYSTEM MFGRD BY PYRO CHEM, INC. MODEL ATD-35/75 -- MEETS UL-1254 6 NOZZLE AIMING POINT FIRE SUPPRESSION SYSTEM LAYOUT - MAIN FUELING AREA SEE GRAPHIC SCALE THIS COPY: SCALE PROJECT ADDRESS SHEETDWG FILE A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. FSP-2AS NOTED SALEM, MA 342 HIGHLAND AVENUE TBD-021-01 SAL2 A.L. PRIME SITE # TBD DE S C R I P T I O N RE V BY DA T E 24 M A Y 2 0 2 1 0 A G O R I G I N A L D R A W I N G D A T E 36 FIRE SUPPRESSION SYSTEM LAYOUT - DIESEL SEE GRAPHIC SCALE 05/24/21 W A Y '31 1 1 3 6' NATURAL CEDAR PLANK FENCE 6' WOOD FENCE HIGHLAND AVENUE B A R C E L O N A A V E N U E UP UP UP UP 5.25.1 6.26.7 8.1 6.7 5.6 3.8 2.7 3.3 1.9 4.1 6.5 8.1 8.5 8.8 10.7 11.2 10.0 5.7 3.5 2.6 1.8 2.3 2.5 1.5 5.2 12.5 21.1 26.5 28.3 28.5 27.2 22.6 16.2 6.6 3.5 2.2 1.5 1.5 2.1 2.0 8.4 23.5 8.2 2.8 1.7 1.2 1.1 1.2 2.5 9.8 24.7 8.0 2.4 1.6 1.3 1.2 2.8 10.9 17.0 5.9 2.1 2.1 3.0 3.1 1.9 3.1 10.9 23.9 12.7 7.2 3.6 2.5 4.2 10.0 10.5 2.9 3.0 3.5 10.1 14.5 5.3 3.3 2.7 4.1 10.9 0.2 10.9 4.0 5.7 5.5 11.1 10.3 3.8 2.8 3.6 8.7 17.7 6.2 6.7 9.4 16.8 26.3 29.9 26.2 16.8 9.7 5.9 3.1 3.3 6.8 17.1 6.2 9.6 14.1 10.9 5.2 3.9 3.5 5.4 14.7 10.1 13.4 11.2 5.2 4.0 4.6 10.0 3.6 9.2 10.5 6.7 5.3 2.1 6.5 1.8 4.9 7.9 10.3 10.2 8.2 7.5 6.9 7.3 2.4 0.9 1.7 5.2 4.2 LUMINAIRE SCHEDULE SYMBOL QTY LABEL ARRANGEMENT LUMENS LLF BUG RATING WATTS/LUMINAIRE TOTAL WATTS MANUFACTURER CATALOG LOGIC 1 A3B SINGLE 10899 1.030 B2-U0-G2 104 104 Cree Inc OSQ-ML-B-DA + OSQM-B-16L-50K9-3M-UL-NM-XX + OSQ-BLSMF 3 A4B SINGLE 12349 1.030 B2-U0-G2 104 312 Cree Inc OSQ-ML-B-DA + OSQM-B-16L-57K7-4M-UL-NM-XX + OSQ-BLSMF 20 C SINGLE 13251 1.030 B3-U0-G1 134 2680 CREE, INC.CAN-304-SL-RD-06-E-UL-XX-700-57K 23 L4 4FT LIGHTBAR 148 1.000 B0-U1-G0 2.9 533.6 MAXLITE INC.LB4850 2 W SINGLE 2490 1.030 B1-U0-G1 19 38 Cree Inc XSPW-B-WM-2ME-2L-57K-UL-XX LUMINAIRE LOCATION SUMMARY LUM NO.LABEL MTG. HT. 1 A3B 17 2 A4B 17 3 A4B 17 4 A4B 17 5 C 18 6 C 18 7 C 18 8 C 18 9 C 16 10 C 16 11 C 16 12 C 16 13 C 16 14 C 16 15 C 16 16 C 16 17 C 16 18 C 16 19 C 16 20 C 16 21 C 16 22 C 16 23 C 16 24 C 16 25 L4 10 26 L4 10 27 L4 10 28 L4 10 29 L4 10 30 L4 10 31 L4 10 32 L4 10 33 L4 10 34 L4 10 35 L4 10 36 L4 10 37 L4 10 38 L4 10 39 L4 10 40 L4 10 41 L4 10 42 L4 10 43 L4 10 44 L4 10 45 L4 10 46 L4 10 47 L4 10 48 W 10 49 W 10 FOOTCANDLE LEVELS CALCULATED AT GRADE USING INITIAL LUMEN VALUES LABEL AVG MAX MIN AVG/MIN MAX/MIN DIESEL CANOPY 31.55 35 25 1.26 1.40 GAS CANOPY 49.47 68 28 1.77 2.43 PAVED AREA 7.81 29.9 0.2 39.05 149.50 UNDEFINED 0.64 7.8 0.0 N.A.N.A. 1 A3B 2 A4B 3 A4B 4 A4B 5 C 6 C 7 C 8 C 9 C10 C 11 C 12 C 13 C 14 C 15 C 16 C 17 C 18 C 19 C 20 C 21 C 22 C 23 C 24 C 25 L4 26 L427 L428 L429 L430 L431 L432 L433 L434 L435 L436 L437 L438 L439 L440 L441 L442 L4 43 L4 44 L4 45 L4 46 L4 47 L4 48 W 49 W NOTE: AREA LIGHTS ON NEW 15 FT. POLES MOUNTED ON 2 FT. CONCRETE BASES 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.00.00.00.00.10.10.10.10.10.10.10.10.10.10.10.0 0.00.00.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.10.00.0 0.00.10.10.10.10.10.10.10.20.20.20.20.20.30.30.20.30.50.40.10.10.1 0.0 0.1 0.1 0.1 0.1 0.2 0.2 0.3 0.3 0.3 0.3 0.4 0.4 0.8 1.0 0.6 0.5 0.7 1.4 2.4 0.5 0.2 0.1 0.1 0.0 0.1 0.1 0.1 0.2 0.3 0.3 0.4 0.5 0.5 0.6 0.6 0.8 1.4 4.9 2.7 1.4 1.2 1.8 3.2 5.3 3.40.60.30.10.1 0.0 0.1 0.1 0.1 0.2 0.3 0.5 0.7 0.9 1.0 1.1 1.1 1.3 2.8 5.4 3.0 2.4 3.8 6.0 4.1 0.4 0.1 0.1 0.0 0.1 0.1 0.1 0.2 0.3 0.5 0.9 1.3 1.8 2.2 2.3 2.4 3.0 5.9 2.5 4.5 7.8 4.3 1.1 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.3 0.5 0.9 3.7 6.6 4.9 2.2 0.3 0.1 0.0 0.00.10.10.20.30.40.7 2.9 3.9 1.9 1.0 0.3 0.1 0.0 0.00.10.10.20.30.61.0 1.81.70.70.40.20.10.0 0.00.10.10.30.50.81.3 1.0 0.9 0.7 0.3 0.2 0.1 0.1 0.0 0.00.10.10.20.30.61.01.5 1.6 0.9 0.5 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.4 0.9 1.6 5.2 1.5 0.5 0.2 0.1 0.1 0.0 0.0 0.1 0.1 0.2 0.6 1.5 2.2 0.5 0.2 0.1 0.0 0.0 0.00.10.10.20.72.2 1.1 0.3 0.1 0.1 0.0 0.00.10.10.20.52.0 0.20.10.10.00.0 0.00.10.10.20.32.0 0.10.00.00.0 0.0 0.1 0.1 0.3 0.8 4.3 0.00.00.00.0 0.0 0.1 0.1 0.2 0.5 1.5 0.00.10.10.1 0.00.10.10.20.30.6 1.3 3.4 0.0 0.4 0.3 0.1 0.0 0.1 0.1 0.2 0.4 2.7 3.2 3.3 3.6 5.7 5.5 6.5 0.0 0.4 2.7 3.0 1.7 1.1 0.3 0.0 0.0 0.1 0.1 0.1 0.0 0.0 0.0 0.1 0.1 0.2 0.3 0.5 0.7 1.1 0.8 0.7 0.5 0.6 3.3 2.4 2.7 0.5 0.0 0.0 0.0 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.3 0.4 0.2 0.2 0.1 0.1 0.3 1.3 2.9 4.0 0.7 0.1 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.6 2.0 1.3 0.1 0.0 0.00.00.00.00.00.10.30.70.30.10.0 0.00.10.20.20.10.0 0.0 0.1 0.1 0.0 0.0 0.0 27 32 35 33 29 32 33 34 33 32 34 33 32 33 33 32 31 27 31 33 30 25 28 39 43 46 47 48 47 48 46 46 42 31 39 33 57 47 58 50 49 58 57 56 35 42 33 45 64 65 35 55 68 62 49 31 46 41 64 55 67 58 56 62 55 57 36 42 40 54 60 63 63 63 56 58 52 49 42 33 45 55 63 64 67 62 57 40 53 59 63 61 59 48 46 41 64 55 65 51 42 34 44 63 66 37 34 40 34 57 47 56 41 32 32 42 46 47 44 41 30 24 MAR 2024 | 3 | AG | ADJ SIDEWALK AT CORNER TO MATCH OTHER SHTS - NO CHANGE TO PHOTOMETRICS A.L. PRIME SALEM, MA SCALE: 1" = 20' D 3/24/21 JSG LAYOUT BY: DWG SIZE: DATE: PROJECT NAME: DRAWING NUMBER: RL-7266-S1-R2 REV. BY DATE DESCRIPTION R1 R2 . . JSG FNE . . 5/11/21 12/2/21 . . REVISE PER UPDATED SITE PLAN REVISED PER UPDATED SITE PLAN . . 1340 Kemper Meadow Dr, Forest Park, OH 45240 513-574-9500 redleonard.com ANY SITE PLAN(S), FLOOR PLAN(S), RENDERING(S), LIGHTING LAYOUT(S) AND PHOTOMETRIC PLAN(S) INCLUDING BUT NOT LIMITED TO ANY PROJECT(S) CREATED/PRODUCED BY RED LEONARD ASSOCIATES INC., ARE ONLY INTENDED FOR ILLUSTRATION AND QUOTING PURPOSES ONLY. RED LEONARD ASSOCIATES HAS THE RIGHT TO USE THIRD PARTY LASERS, SCANNERS, AND CAMERAS BUT ACTUAL PROJECT CONDITIONS, DIMENSIONS, AND ACCURACY OF MEASUREMENTS MAY DIFFER FROM THESE OR ANY PARAMETERS. RED LEONARD ASSOCIATES INC. ASSUMES NO LIABILITY FOR WHAT IS CREATED/PRODUCED IN THESE RECREATIONS. THIS INCLUDES BUT IS NOT LIMITED TO THE USE OF, INSTALLATION OF AND/OR INTEGRITY OF EXISTING BUILDING(S), SURROUNDING AREA FOR PRODUCT(S) SUCH AS EXISTING POLE(S), ANCHOR BOLT(S), BASE(S), ARCHITECTURAL AND SIGNAGE STRUCTURE(S), LANDSCAPING PLAN(S), LIGHTING PLAN(S), FIXTURE SELECTION(S) AND PLACEMENT, MATERIAL(S), COLOR ACCURACY, TEXTURE(S), AND ANYTHING ATTRIBUTED TO PHOTO REALISM THAT IS CREATED. FURTHERMORE, RED LEONARD ASSOCIATES INC., DOES NOT ASSUME LIABILITY WHATSOEVER FOR ANY PURCHASES MADE BY CLIENT BEFORE, DURING, OR AT THE CONCLUSION OF THE PUBLISHED WORK. THE CUSTOMER, ITS RELATIVE AFFILIATES, AS WELL AS ANY OTHER PERSON(S) IN VIEWING OF THIS PRODUCT IS RESPONSIBLE FOR VERIFYING COMPLIANCE WITH ANY BUT NOT LIMITED TO ALL CODES, PERMITS, RESTRICTIONS, INSTRUCTIONS, PURCHASES, AND INSTALLATIONS OF OBJECTS VIEWED WITHIN THIS DOCUMENT(S) OR PROJECT(S). SYMBOLS ARE NOT DRAWN TO SCALE. SIZE IS FOR CLARITY PURPOSES ONLY. SIZES AND DIMENSIONS ARE APPROXIMATE, ACTUAL MEASUREMENTS MAY VARY. DRAWINGS ARE NOT INTENDED FOR ENGINEERING OR CONSTRUCTION USE. THIS DOCUMENT, ANY RED LEONARD DRAWING(S), OR PROJECT(S) IS NOT TO BE USED AND/OR INTENDED FOR ENGINEERING OR CONSTRUCTION PURPOSES, BUT FOR ILLUSTRATIVE PURPOSES ONLY. ANY LOCATIONS OF EMERGENCY LIGHTING SHOWN WERE PROVIDED BY OTHERS. RED LEONARD ASSOCIATES IS NOT RESPONSIBLE FOR INSUFFICIENT LIGHTING DURING AN EMERGENCY EVENT. ANY USE OF THIS DOCUMENTATION AND/OR OTHER ARTICLES PRODUCED BY RED LEONARD WITHOUT WRITTEN AUTHORIZATION FROM JAYME J. LEONARD IS STRICTLY PROHIBITED. DISCLAIMER THIS SITE IS LOCATED IN A REGION WHERE LIGHTING IS REGULATED BY LOCAL ORDINANCES 37 EMGCY VEHICLE 100' LADDER TRUCK SEE GRAPHIC SCALE FUEL DELIVERY TANKER SCALE PROJECT ADDRESS SHEETDWG FILE PATHS A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. VEHICLE TR-1.0AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 DE S C R I P T I O N RE V BY DA T E 24 M A Y 2 0 2 1 0 A G O R I G I N D A T E O F D R A W I N G AUTOTURN SWEPT PATH ANALYSIS 38 02 S E P 2 0 2 1 1 A G N O C H A N G E T O S W E P T P A T H , R E V I S E D T O S H O W A D J P V M N T L E G E N D 3/25/24 08 N O V 2 0 2 1 2 A G R E V P E R P E E R R E V I E W ( A D D E D S I D E W A L K ) 24 M A R 2 0 2 4 3 A G R E V P E R M A D O T C M T S - A D J S I D E W A L K - N O C H A N G E T O S W E P T P A T H 1 2 4 1 2 6 1 2 8 13 0 122 1 2 2 1 2 0 124 1 2 6 12 0 11 8 123 1 2 2 1 1 7 117 1 1 8 11 9 1 2 0 12 1 12 2 1 2 3 1 1 8 12 412 5 13 0 128 12 6 124 12 8 1 2 0 1 1 8 12 2 129 127 12713 2 129 13 1 12 5 125 1 2 5 1 2 4 1 2 8 1 2 7 1 2 6 1 2 3 1 1 9 1 3 0 1 3 2 HIGHLAND AVENUE BA R C E L O N A A V E N U E 132. 2 5 x 131. 0 4 x131. 9 4 x 132. 0 6 x 131. 4 0 x 131. 9 2 x132. 7 4 x 132. 7 9 x 131. 1 5 x 131. 9 3 x 131. 9 5 x 131. 2 4 x131. 8 7 x132. 0 9 x 131. 2 9 xx132. 0 6 x 131. 2 8 x131. 5 2 x 131. 8 1 x 130. 5 9 x131. 3 9 x 131. 7 0 x 130. 7 0 x 130. 2 7 x130. 5 9 x 131. 6 6 131. 2 9 x x131. 2 2 13 4 13 6 13 8 14 0 1 2 4 1 2 6 1 2 8 13 0 122 1 2 2 1 2 0 124 1 2 6 12 0 11 8 1 2 2 1 1 8 11 9 12 0 12 1 12 2 1 2 3 1 1 8 1 2 4 12 5 13 0 128 12 6 124 12 8 1 2 0 1 1 8 12 2 13 2 1 2 4 1 2 8 1 2 6 E6 (abutter) Grass 5,110 E1-C Grass/Shrub 36,289 E1-B Pvmnt 2,789 E1-A Grass 3,003 E5 (to ROW) Grass 931 E1-E Pvmnt 2,849 E1-D Grass 402 1 3 0 1 3 2 HIGHLAND AVENUE BA R C E L O N A A V E N U E E6-B Pvmnt 1,032 E1-F Pvmnt 3,892 E1-G Grass 6,596 E6-C Grass 956 13 4 13 6 13 8 14 0 1 2 4 1 2 6 1 2 8 13 0 122 1 2 2 1 2 0 124 1 2 6 12 0 11 8 126 127 12 8 12 9 13 0 13 1 126 1 2 5 12 4 1 1 9 1 2 0 1 2 2 12 7 1 2 1 1 1 8 11 9 1 2 0 12 1 12 2 1 2 3 1 1 8 12 4 12 5 13 0 128 12 6 124 1 2 5 12 8 12 9 125 1 2 4 124 1 2 4 125 127 12 8 12 6 . 0 12 2 1 2 0 1 1 8 1 2 2 1 1 8 12 2 125 124 12 1 13 0 1 2 9 1 2 8 1 2 7 126 13 2 125 1 2 3 12 3 123 123 1 2 4 1 2 8 1 2 6 127 1 2 6 1 2 3 CANOPY C-STORE CB2 CB1 SC U N D E R G R O U N D T A N K S CANOPY 1 3 0 1 3 2 CB3 DMH2 DMH1 HIGHLAND AVENUE BA R C E L O N A A V E N U E CB4 CB5 DMH3 O/G 13 1 OHW OHW OHW OHW OHW OHW 13 4 13 6 13 8 14 0 124 126 127 12 8 12 9 13 0 13 1 126 1 2 5 12 4 1 1 9 1 2 0 12 7 1 2 1 1 2 5 12 8 12 9 125 1 2 4 124 1 2 4 125 127 12 6 . 0 12 2 1 1 8 1 2 2 125 124 12 1 13 0 1 2 9 1 2 8 1 2 7 126 125 1 2 3 12 3 123 123 127 1 2 6 1 2 3 S2-A Grass 207 S3-I Roof 3,849 S1-B Roof 2,815 S1-A Roof 583 S3-B Grass 2,407 S4-B Grass 17,441 S6 (abutter) Grass 5,110 S3-E Pvmnt 1,386 S3-C Pvmnt 7,795 S5 (to ROW) Grass - 207 Pvmnt - 14 S3-D Grass 429 S4-A Pvmnt 175 S2-B Pvmnt 4,531 S3-A Pvmnt 3,339 HIGHLAND AVENUE BA R C E L O N A A V E N U E S6-B Pvmnt 1,032 S2-D Pvmnt 1,744 S3-H Pvmnt 1,085 S3-G Grass 682 S2-E Grass 5,172 S6-C Grass 956 S3-F Pvmnt 434 S4-C Pvmnt 651 13 1 OHW OHW OHW OHW OHW OHW ( S 3 - B ) 124 S2-E2 Grass 742 S2-D2 Pvmnt 1,063 PRE AND POST DEVELOPMENT STORMWATER RUNOFF AREAS AND FLOW DIRECTIONS SEE GRAPHIC SCALE POST DEV RUNOFF AREASPRE DEV RUNOFF AREAS EXISTING SITE LAYOUT SCALE PROJECT ADDRESS SHEETDWG FILE ANALYSIS A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. STORMWATER SW-1AS NOTED SALEM, MA 342 HIGHLAND AVENUE 161-021-01 SAL2 A.L. PRIME SITE # 161 DE S C R I P T I O N RE V BY DA T E 24 M A Y 2 0 2 1 0 A G O R I G I N A L D R A W I N G D A T E PROPOSED LAYOUT GENERAL NOTES 1. THE GENERAL PURPOSE OF THIS WORK IS TO CONSTRUCT A NEW GAS STATION AND CONVENIENCE STORE. 2. STORMWATER IMPACTS OF THE PROPOSED DEVELOPMENT HAVE BEEN MODELED IN HYDROCAD AND RUNOFF MITIGATION HAS BEEN DESIGNED AS INFLUENCED BY THAT MODELING TO REDUCE POST DEVELOPMENT RUNOFF BELOW PRE-DEVELOPMENT RATES AND VOLUMES. PLEASE REFER TO THE STORMWATER MANAGEMENT PLAN. 3. THE LAYOUTS ON THIS SHEET ARE INCLUDED IN THE STORMWATER MANAGEMENT PLAN AND USED IN THE HYDROCAD MODEL. 4. THE STORMCEPTOR WILL BE EQUIPPED WITH A MFGR DESIGNED "SUBMERGED MODIFICATION". 39 02 S E P 2 0 2 1 1 A G A D D E D N O T E T H A T T H I S S H E E T N O T R E V I S E D P E R N E W P A V E M E N T L E G E N D 3/24/24 08 N O V 2 0 2 1 2 A G R E V P E R P E E R R E V I E W - A D D E D B A R C E L O N A A N D O F F S I T E C A T C H M E N T 30 N O V 2 0 2 1 3 A G A D J U S T E D C U R B I N G A N D A R E A S P E R L A Y O U T R E V I S I O N S 24 M A R 2 0 2 4 4 A G R E V P E R M A D O T C M T S - A D J S U B C A T C H M E N T S S 2 D A N D S 2 E NORTHEAST SOUTHEAST (FACING HIGHLAND AVE) .9 10000 REGULAR UNLEADED SOUTHWEST (FACING BARCELONA)SOUTHEAST (FACING HIGHLAND AVE) MAIN CANOPY ELEVATIONS (FRONT) SEE GRAPHIC SCALE GENERAL NOTES 1. THIS PLAN FOR BOARD HEARINGS ONLY. REFER TO STEEL MANUFACTURER'S STAMPED DRAWINGS FOR BUILDING PERMIT AND CONSTRUCTION. 2. MINIMUM CLEARANCE 15'-0". 3. ALL TOP OF FOOTINGS AT SAME ELEVATION - 30" BELOW TO OF ISLAND AT ISLAND WITH LOWEST ELEVATION. 4. CANOPY DRAINS EXTERNAL TO THE COLUMN AND ROUTED TO UG INFILTRATION SYSTEM BY UG PIPING 5. ALL LIGHTING RECESSED IN CANOPY DECK AND ALL LIGHTING ARE LED FIXTURES 6. SIGNAGE SHOWN FOR INFORMATION ONLY, ALL SIGNAGE TO BE APPLIED FOR SEPARATELY AND LIMITED TO AS ALLOWED BY RIGHT. ALL SIGNAGE SUBJECT TO CITY OF SALEM SIGN BOARD APPROVAL. DIESEL ELEVATIONS SEE GRAPHIC SCALE SCALE PROJECT ADDRESS SHEETDWG FILE ELEVATIONS DE S C R I P T I O N RE V BY DA T E A.L. PRIME ENERGY SAUGUS MA 01906 (781)246-0201 18 LARK AVENUE CONSULTANT, INC. CANOPY A-2.3 AS NOTED SALEM, MA 342 HIGHLAND AVENUE TBD-021-01 SALEM A.L. PRIME SITE # tbd 24 M A Y 2 0 2 1 0 A G O R I G I N D A T E O F D R A W I N G 40 09/02/2021 02 S E P 2 0 2 1 1 A G S M A L L E R P R I C E S I G N P E R D R B C M T S