435-443 HIGHLAND AVENUE - SIGN PERMIT - EXTRASPACE STORAGECity of Salem Sign Permit Application Worksheet
Zoning (res/non-res)B2 nonresidential Multiplier
Entrance Corridor (Y/N)Y building distance from street center if entrance corridor
Lot frontage 345 feet <100 feet 2.00 1.00
Building or tenant frontage 285.00 feet 100-399 feet 2.50 1.25
# of businesses on site 1 >400 feet 3.00 1.50
Bldng dist from street center <100 feet feet
Multiplier 1
Building and Blade Signs Building Sign Area
maximum area permitted 285.00 sq ft =building frontage x multiplier
if non conform in res zone=1/2 of above
total proposed sign area 228.82 sq ft
Blade Sign Area
Wall Sign 1 167.85 sq ft
width 447.60 inches
height 54.00 inches
Wall Sign 2 57.38 sq ft
width 135.00 inches
height 61.20 inches
Awning 3.59 sq ft
width 45.00 inches
height 11.50 inches
Freestanding Signs NONE maximum of 24 sq ft per side
maximum area permitted 32.50 sq ft (per side)(12 sq ft per side in entry corridor)
maximum # of signs permitted 2 signs 24 (or 12) counts toward max area
maximum height permitted 12.50 ft tall
Window Decal
sign 1
proposed sign area 54.50 sq ft
length 107.50 inches
height 73.00 inches
Application meets guidelines set
forth in the Salem Sign Ordinance Y
Recommend approval Y
Freestanding Signs: Maximum Number, Area and Height
Lot frontage < 200 feet
Businesses on site 1 or 2 3 or more
Non-residential 1 sign 1 sign
65 sq ft 125 sq ft per side
25 ft tall 30 ft tall
Entry corridor 1 sign 1 sign
32.5 sq ft.62.5 sq ft per side
12.5 ft tall 15 ft tall
If lot frontage is >200 feet, then 2 signs with sq ft and height for each applies.
maximum of 20% of window dt; 30% elsewhere
24-Jul-23
ExtraSpace Storage
435-443 Highland Avenue
Notes: Freestanding sign is a refacing of an existing
freestanding sign that is illuminated. The sign application
meets the size and lighting standards of the zoning code.
37'-7 1/16"
11457mm
22'-5 7/8"
6855mm
14'-9 11/16"
4513mm
2'-7 1/16"
788mm
3'-6 7/16"
1077mm
4'-5 13/16"
1366mm
6 1/2"
165mm
39'-0"
11887mm
1'-8 1/16"
509mm
6'-0"
1829mm
8 1/4"
210mm
4 3/4"
120mm
A
FRONT ELEVATION
SEE EXSS-WPL-007-NL-SF-072H-X
FOR DETAILS
P5
5"
127mm
2"
51mm
8"
203mm
SIDE ELEVATION
P4
ISOMETRIC VIEW
TOP ELEVATION
R2 9/16"
65mm
R2 3/16"
56mm
2 15/16"
75mm
2 3/8"
60mm
DETAIL A
SCALE: 1 : 8
V2
V3
Letterset Details
NIGHT VIEW
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-021-IL-EX-053H-X
EXTRA SPACE STORAGE
EXSS-MA001
9/14/2023
Letterset
HMD
INITIAL CREATION9/14/2023HMDA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-20 WHITE(V2)
3M 3630-22 BLACK(V3)
MP 923SP SATIN BLACK
MP N202 SATIN WHITE
(P4)
(P5)
SHEET 1 OF 3
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
COL1
POL1
SHT1
LED1
BUS1
HDW3
WIR1
HDW4
HDW1
B
HDW6
A
SECTION DETAIL (WITH SPACERS) - CORRUGATED METAL BUILDINGSCALE: N.T.S.
A
B PAINTED TO MATCH RETURNS
SPACERS PAINTED TO MATCH BUILDING COLOR
RVT1
HDW5
P5
P4
1"
25
1/4"
6
1 3/4"
44
11/16"
17
3/8"
10
3/16"
5
2"
51
2 3/4"
70
1"
25
1"
25
3/16"
5
SHT1
BRACE ISO VIEW
SCALE: N.T.S.BRACE - TOP VIEW
SCALE: N.T.S.
BRACE - RIGHT SIDE VIEW
SCALE: N.T.S.
5"[127mm]
Corrugated Metal with
Spacers Mounting
MANUFACTURING BILL OF MATERIALS
ITEM #PART #DESCRIPTION
COL1 AL-SH-063-48-120 .063 x 48 x 120 ALUMINUM SHEET
SHT1 AL-SH-125-60-120 .125 x 60 x 120 ALUMINUM SHEET
POL1 PCLEA-177-60-120 .177 x 60 x 120 CLEAR POLYCARBONATE
HDW1 HW-00220 #8 X 1" HEX WASHER HEAD SELF-DRILLING SCREW ZINC
RVT1 HW-00109 Blind Rivet 3/16"x5/8"
LED1 USLED-PXL2-2-12-W US LED PXL2-2-12-2 1.5 MODULES/FT 1260/CASE
BUS1 EL-EC-00049 Arlington 4400 bushing
HDW3 HW-00059 3/8" NUTCERT
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION
WIR1 EL-EC-00001 16-2 STR SHLD CMP/CL3P WIRE
PWS1 USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 10/CASE
HDW4 HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW
HDW5 HW-00085 3/8 Stainless Steel Flat Washer
HDW6 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE
ANG1 AL-EX-375-4-6-25-ANGLE 3/8" X 4 X 6 X 25FT ALUM ANGLE
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-021-IL-EX-053H-X
EXTRA SPACE STORAGE
EXSS-MA001
9/14/2023
Letterset
HMD
INITIAL CREATION9/14/2023HMDA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-20 WHITE(V2)
3M 3630-22 BLACK(V3)
MP 923SP SATIN BLACK
MP N202 SATIN WHITE
(P4)
(P5)
SHEET 2 OF 3
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
Purchasing BOM
PURCHASING BOM
MANUFACTURING BILL OF MATERIALS
PART #DESCRIPTION QTY.
HW-00220 #8 X 1" HEX WASHER HEAD SELF-DRILLING SCREW
ZINC A/R
HW-00109 Blind Rivet 3/16"x5/8"A/R
AL-SH-063-48-120 .063 x 48 x 120 ALUMINUM SHEET TBD
LF
AL-SH-125-60-120 .125 x 60 x 120 ALUMINUM SHEET TBD
SF
PCLEA-177-60-120 .177 x 60 x 120 CLEAR POLYCARBONATE TBD
LF
USLED-PXL2-2-12-W US LED PXL2-2-12-2 1.5 MODULES/FT 1260/CASE TBD
EA EL-EC-00049 Arlington 4400 bushing 17 EA
HW-00059 3/8" NUTCERT 51 EA
INSTALLATION BILL OF MATERIALS
PART #DESCRIPTION QTY.
EL-EC-00001 16-2 STR SHLD CMP/CL3P WIRE 170 LF
USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W
10/CASE
TBD
EA
HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW 51 EA
HW-00053 3/8-16 Stainless Steel Finished Hex Nut 51 EA
AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 6 LF
MOUNTING MOUNTING PATTERN 1 EA
TOUCHUP-PAINT TOUCH-UP PAINT 1 EA
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-021-IL-EX-053H-X
EXTRA SPACE STORAGE
EXSS-MA001
9/14/2023
Letterset
HMD
INITIAL CREATION9/14/2023HMDA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-20 WHITE(V2)
3M 3630-22 BLACK(V3)
MP 923SP SATIN BLACK
MP N202 SATIN WHITE
(P4)
(P5)
SHEET 3 OF 3
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
3'-6"
1067mm
14'-8 3/4"
4489mm
22'-3 7/16"
6793mm
37'-3 3/16"
11359mm
4'-5 1/4"
1353mm
8 3/16"
208mm
4 11/16"
119mm
FRONT VIEW
SCALE: 1 : 48
V4
V3
V1
(SHT1) PAINTED TO MATCH
RACEWAY - SEE SITEDOC FOR
PAINT
A
5"
127mm
9 1/4"
235mm
SIDE VIEW
SCALE: 1 : 48
ISO VIEW
SCALE: 1 : 64
Letterset Details
NIGHT VIEW - INTERNAL ILLUMINATION
"REGISTRATION" MOUNTED TO LETTER RETURN
WITH TEK SCREWS
A
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-505-IL-RW-053H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-106 GREENV1
3M 3630-22 BLACKV3
V4 3M 3635-222 DUAL COLOR BLACK
MP# 923SP SATIN BLACKP4
SHEET 1 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:48
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
22'-2 15/16"
6781mm
13'-9 5/16"
4199mm
4"
102mm
4"
102mm
3'-0"
914mm
3'-0"
914mm
3'-0"
914mm
3'-0"
914mm
3'-0"
914mm
3'-0"
914mm
4"
102mm
3'-0"
914mm
3'-0"
914mm
3'-0"
914mm
12'-9 1/2"
3899mm
SEAM
RACE WAY BACK VIEW
SCALE: 1:32
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-505-IL-RW-053H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-106 GREENV1
3M 3630-22 BLACKV3
V4 3M 3635-222 DUAL COLOR BLACK
MP# 923SP SATIN BLACKP4
SHEET 2 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:32
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
5"[127mm]
EIFS with Raceway Mounting
SECTION DETAIL (WITH RACEWAY) - EIFSSCALE: N.T.S.
SEE RACEWAY DETAILS SHEET
HDW5
B
A
HDW1
HDW4
HDW3
ANG1
HDW2
LED1
SHT2
ACR1
TRC1
COL1
A
B
PAINTED TO MATCH RETURNS
(MIN 2) 1/4" WEEP HOLES PER LETTER, LOCATE AT EACH LOW POINT WITH LIGHT SHIELD COVER
BRC1
SCALE: N.T.S.BRICK / CONCRETE / TILEMOUNTING OPTION B (WITH RACEWAY)-
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION
HDW2 HW-00123 3/8-16 x 12" SS ALL THREAD STUD
HDW3 HW-00053 3/8-16 Stainless Steel Finished Hex Nut
HDW4 HW-00085 3/8 Stainless Steel Flat Washer
HDW5 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE
ANG1 AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE
MANUFACTURING BILL OF MATERIALS
ITEM #PART #DESCRIPTION
COL1 AL-CO-040-5_3-270-BLAC 5.3" x .040" x 270' Gloss Black Aluminum Coil
TRC1 TR-MG-1-150-4310-DOGR-R 1" 4310 DOVE GREY GEMINI
ACR1 A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC
SHT2 AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET
HDW1 HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL SCREW 410 S/S
LED1 USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE
ELEC1 EL-EC-00121 HEYCO M4812 SCG 750 SNAP-IN CORDGRIP STRAIN RELIEFS (50/BOX)
ELEC2 PG-9841814L-WIRE PAIGE 98P1814L RIP STRIP LED CABLE 18-2 CONDUCTOR MOISTURE
RESISTANT 500FT ROLL
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION QTY.
BRC1 HW-00275
3/8" x 3" HEAVY DUTY HEX
HEAD TAPPING SCREW FOR
CONCRETE SCREW
TBD
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
EXSS-LTR-505-IL-RW-053H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
SHEET 3 OF 6
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
C
RCW2
RACEWAY SECTION VIEWSCALE: N.T.S.
ELC2
B
RCW3RHD3
RHD2
A
RCW1
ELC3
ELC1
RHD1
EYB1
Raceway Details
B 1/4" PLATE DRILLED & TAPPED FOR EYEBOLT
(PLATE WELDED TO RACEWAY INTERIOR AS REQ'D)
INSTALLER TO REMOVE EYEBOLT AFTER INSTALL & REPLACE W/ (ITEM EYB2)A
C RIP OPENING IN ONE SIDE OF TUBE TO FIT ELECTRICAL
4"
D
D
F
HDW2
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION
EYB2 HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251
ELC2 EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington
NMLT9050)
ELC3 EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit
MANUFACTURING BILL OF MATERIALS
ITEM #PART #DESCRIPTION
RCW1 AL-SH-090-60-144 .090 x 60 x 144 ALUMINUM SHEET
RCW2 AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE
RCW3 AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR
EYB1 HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR
LIFTING
RHD1 HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW
RHD2 HW-00053 3/8-16 Stainless Steel Finished Hex Nut
RHD3 HW-00085 3/8 Stainless Steel Flat Washer
SHT1 AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET
ELC1 EL-EC-00052 3/8" ARLINGTON BUSHING
HDW1 HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3
HDW2 HW-00048 #8 x 1/2" SS Self-Drilling Screw
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-505-IL-RW-053H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-106 GREENV1
3M 3630-22 BLACKV3
V4 3M 3635-222 DUAL COLOR BLACK
MP# 923SP SATIN BLACKP4
SHEET 4 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
Purchasing BOM
PURCHASING BOM
MANUFACTURING BILL OF MATERIALS
PART #DESCRIPTION QTY.
HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL
SCREW 410 S/S A/R
AL-CO-040-5_3-270-BLAC 5.3" x .040" x 270' Gloss Black Aluminum Coil 233'4"
TR-MG-1-150-4310-DOGR-R 1" 4310 DOVE GREY GEMINI 233'-
4"
A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC 85 SF
AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET 120 SF
USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE 203
EL-EC-00052 3/8" ARLINGTON BUSHING 2
EL-EC-00121 HEYCO M4812 SCG 750 SNAP-IN CORDGRIP STRAIN
RELIEFS (50/BOX)2
PG-9841814L-WIRE PAIGE 98P1814L RIP STRIP LED CABLE 18-2 CONDUCTOR
MOISTURE RESISTANT 500FT ROLL 5 LF
USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 5
AL-SH-090-60-144 .090 x 60 x 144 ALUMINUM SHEET 10 SF
AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE 36 LF
AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR 2 SF
HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR
LIFTING 4 EA
HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW 95 EA
HW-00053 3/8-16 Stainless Steel Finished Hex Nut 95 EA
HW-00085 3/8 Stainless Steel Flat Washer 95 EA
HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3 8 EA
HW-00048 #8 x 1/2" SS Self-Drilling Screw 20
AL-FB-500-2-144 .5 x 2 x 12' ALUMINUM FLAT BAR 2 SF
INSTALLATION BILL OF MATERIALS
PART #DESCRIPTION QTY.
EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington
NMLT9050)2
EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit 2
HW-00275 3/8" x 3" HEAVY DUTY HEX HEAD TAPPING SCREW
FOR CONCRETE SCREW 26
HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251 4 EA
HW-00123 3/8-16 x 12" SS ALL THREAD STUD 26
HW-00053 3/8-16 Stainless Steel Finished Hex Nut 52
HW-00085 3/8 Stainless Steel Flat Washer 52
AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 13 LF
AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE 24 LF
MOUNTING MOUNTING PATTERN 1 EA
TOUCHUP-PAINT TOUCH-UP PAINT - (P4)1 EA
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-505-IL-RW-053H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-106 GREENV1
3M 3630-22 BLACKV3
V4 3M 3635-222 DUAL COLOR BLACK
MP# 923SP SATIN BLACKP4
SHEET 5 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-505-IL-RW-053H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-106 GREENV1
3M 3630-22 BLACKV3
V4 3M 3635-222 DUAL COLOR BLACK
MP# 923SP SATIN BLACKP4
SHEET 6 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:48
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
11 1/2"
292mm
1'-2"
356mm
3'-9 5/16"
1151mm
1 13/16"
47mm
FRONT VIEW
SCALE: 1 : 8
V4
SEE SITEDOC FOR
PAINT SPEC
3"
76mm
7 1/4"
184mm
4"
102mm
4"
102mm
SIDE VIEW
SCALE: 1 : 8
ISO VIEW
SCALE: 1 : 12
Letterset Details
NIGHT VIEW - INTERNAL ILLUMINATION
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-585-IL-RW-014H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4
SHEET 1 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:32
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
3'-9"
1143mm
4"
102mm
4"
102mm
RACEWAY - BACK
SCALE: 1 : 12
BRAKE-FORMED .125"
MOUNTED TO BACKS OF LETTERS
AND A TOP OF RACEWAY
W/ (HDW1) TEK SCREW
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-585-IL-RW-014H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4
SHEET 2 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:32
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
SECTION DETAIL (WITH RACEWAY) - EIFSSCALE: N.T.S.
SEE RACEWAY DETAILS SHEET
HDW5
B
A
HDW1
HDW4
HDW3
ANG1
HDW2
LED1
SHT1
ACR1
TRC1
COL1
A
B
PAINTED TO MATCH RETURNS
(MIN 2) 1/4" WEEP HOLES PER LETTER, LOCATE AT EACH LOW POINT WITH LIGHT SHIELD COVER
5"[127mm]
EIFS with Raceway Mounting
SHT2
BRC1
SCALE: N.T.S.BRICK / CONCRETE / TILEMOUNTING OPTION B (WITH RACEWAY)-
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION
HDW2 HW-00123 3/8-16 x 12" SS ALL THREAD STUD
HDW3 HW-00053 3/8-16 Stainless Steel Finished Hex Nut
HDW4 HW-00085 3/8 Stainless Steel Flat Washer
HDW5 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE
ANG1 AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE
MANUFACTURING BILL OF MATERIALS
ITEM #PART #DESCRIPTION
COL1 AL-CO-040-3_5-270-BLAC-
GLO 3.5 x .040 x 270' GLOSS BLACK ALUMINUM COIL
TRC1 TR-MJ-1-150-BLAC-R 1" BLACK JEWELITE TRIMCAP
ACR1 A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC
SHT1 AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET
SHT2 AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET
HDW1 HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL
SCREW 410 S/S
LED1 USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE
ELEC1 EL-EC-00121 HEYCO M4812 SCG 750 SNAP-IN CORDGRIP STRAIN
RELIEFS (50/BOX)
ELEC2 PG-9841814L-WIRE PAIGE 98P1814L RIP STRIP LED CABLE 18-2 CONDUCTOR
MOISTURE RESISTANT 500FT ROLL
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION QTY.
BRC1 HW-00275 3/8" x 3" HEAVY DUTY HEX HEAD TAPPING
SCREW FOR CONCRETE SCREW 4
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
EXSS-LTR-585-IL-RW-014H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
SHEET 3 OF 6
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
7"
178mm
2"
51mm
4"
102mm
1 1/2"
38mm
1"
25mm
1/2"
13mm
MOUNTING PLATE
SCALE: 1 : 4
RCW3
Raceway Details
B 1/4" PLATE DRILLED & TAPPED FOR EYEBOLT
(PLATE WELDED TO RACEWAY INTERIOR AS REQ'D)
INSTALLER TO REMOVE EYEBOLT AFTER INSTALL & REPLACE W/ (ITEM EYB2)A
C RIP OPENING IN ONE SIDE OF TUBE TO FIT ELECTRICAL
4 1/2"
1/4" WEEP HOLES, LOCATE ALONG BOTTOM.D
D
C
RCW2
RACEWAY SECTION VIEWSCALE: N.T.S.
ELC2
B
RCW3
A
RCW1
ELC3
ELC1
EYB1
HDW1
MANUFACTURING BILL OF MATERIALS
ITEM #PART #DESCRIPTION
RCW1 AL-SH-090-60-144 .090 x 60 x 144 ALUMINUM SHEET
RCW2 AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE
RCW3 AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR
EYB1 HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR
LIFTING
RHD1 HW-00044 1/4"-20 x 2" HEX CAP SCREW GRADE 5 ZINC PLATED
RHD2 HW-00093 1/4" Split Lock Washer Stainless Steel
RHD3 HW-00052 1/4"-20 Stainless Steel Hex Nut
SHT1 AL-SH-125-48-96 .125 X 48 X 96 ALUMINUM SHEET (ROUTED GUSSETS)
ELC1 EL-EC-00052 3/8" ARLINGTON BUSHING
HDW1 HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION
EYB2 HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251
ELC2 EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington
NMLT9050)
ELC3 EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-585-IL-RW-014H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4
SHEET 4 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
Purchasing BOM
PURCHASING BOM
INSTALLATION BILL OF MATERIALS
PART #DESCRIPTION QTY.
EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington
NMLT9050)2
EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit 2
HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251 2 EA
HW-00044 1/4"-20 x 2" HEX CAP SCREW GRADE 5 ZINC PLATED 4HW-00093 1/4" Split Lock Washer Stainless Steel 8
HW-00052 1/4"-20 Stainless Steel Hex Nut 4
AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 2 LF
AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE 12 LF
HW-00275 3/8" x 3" HEAVY DUTY HEX HEAD TAPPING SCREW
FOR CONCRETE SCREW 4
MOUNTING MOUNTING PATTERN 1 EA
TOUCHUP-PAINT TOUCH-UP PAINT - (P4)1 EA
MANUFACTURING BILL OF MATERIALS
PART #DESCRIPTION QTY.
HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL
SCREW 410 S/S A/R
AL-CO-040-3_5-270-BLAC-
GLO 3.5 x .040 x 270' GLOSS BLACK ALUMINUM COIL 29'2"
TR-MJ-1-150-BLAC-R 1" BLACK JEWELITE TRIMCAP 29'-2"
A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC 4 SF
AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET 30 SF
AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET 4 SF
USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE 25
MOD
EL-EC-00052 3/8" ARLINGTON BUSHING 2
USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 1
AL-SH-090-48-120 .090 x 48 x 120 ALUMINUM SHEET 2 SF
AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE 3'-9"
AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR 1 SF
HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR
LIFTING 2 EA
HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3 24 EA
AL-FB-500-2-144 .5 x 2 x 12' ALUMINUM FLAT BAR 2 SF
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-585-IL-RW-014H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4
SHEET 5 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-LTR-585-IL-RW-014H
EXTRA SPACE STORAGE
VARIOUS
8/24/2021
Letterset & Raceway
JMB
INITIAL CREATION8/24/2021JMBA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4
SHEET 6 OF 6
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:1
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
5 Technology Circle ∙ Columbia, SC ∙ 29203 ∙ USA
+1.803.926.7926 P ∙ +1.803.926.8412 F
www.colite.com
SITE DOCUMENT
June 14, 2023
EXSS-MA001-R01
# 3120
435 Highland Ave
Salem, MA 01970
June 14, 2023 ∙ EXSS-MA001-R01 Page 2 of 9
Corrugated Drywall
Brick
Wood, Marble, Glass, and Granite
Concrete
Sidings
Stucco and EIFS
Wallpaper
Exterior Interior
To be discussed with client. End result should ensure holes are filled or patched
prior to installing new sign.
Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex
caulk. Prep and paint wall to a Level 4 finish with approved paint color (SHERWIN
WILLIAMS or BENJAMIN MOORE).
Holes to be filled with QUICKRETE mortar repair sealant or paintable caulk.
Pressure wash wall.To be discussed with client prior to budget presentation.
Holes to be filled with QUICKRETE concrete repair sealant. Pressure wash wall.
Patch holes with pre-approved painted aluminum.
Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex caulk.
Prep and paint wall with approved paint color (SHERWIN WILLIAMS or BENJAMIN
MOORE).
* Paint must cure for a minimum of 48 hours prior to graphics installation. Gassing and/or peeling of graphic can occur otherwise.
* Electrical is to be brought to signage area prior to sign installation by GC or owner.
Wallpaper to be removed and reapplied. PM to consult with client as they may
have access to matching wallpaper.
WALL REPAIR GUIDELINES
June 14, 2023 ∙ EXSS-MA001-R01 Page 3 of 9
A.)Project Name:
B.)Street Address:
C.)Town / City / State / Zip:
D.)Contact for Permit/Zoning:
E.)Contact Telephone:
Contact E-Mail if available:
F.)Jurisdiction: City/Town
or, County of:
G.)Zoning Classification for property:
H.)Is there a Master Sign Plan?
I.)Is a permit required?
J.)
K.)How long is the permit process?
L.)What are the fees for a sign permit?
M.)Is engineering needed for wall signs?
N.)Does engineering require a PE stamp?
Are hard copies needed? How many?
O.)Is landlord approval required?
P.) Legal Description Required for permit?
Q.)Plat/Site Plan required for permit?
R.)Certificate of Occupancy required for permit?
S.)Any special design reviews required (explain)?
If yes, projected processing time?
1.)
2.)
3.)
4.)
5.)
EXTRA SPACE STORAGE # 3120
$25 plus $11.00 per $1000
(978) 619-5685
City of Salem
Salem, MA 01970City, ST Zip:
Yes.
Yes.
bforrestal@salem.com
How is the sign area calculated?
The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display area of
the sign, together with any backing different in color or material from the finish material of the building face,
without deduction for open space or other irregularities. Structural members not bearing advertising matters
hall not be included unless internally or decoratively lighted. Only one side of flat, back-to-back signs need be
included in calculating sign area.
B2; Business Highway; Entrance Corridor Overlay (Requires additional reviews; See below)
Per Beth: Follow the Design Guidelines and the code.
ATTACHED SIGNS (WALL SIGNS & AWNING/CANOPY SIGNS)
Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first
floor, freestanding signs, and directional signs:
Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by
0—99 2
100—399 2.5
400 and over 3
However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent
signs.
Formula for calculating wall sign square
footage (Max. Sq. Footage - Primary &
Secondary signs):
PRE-PERMIT SIGN INFO
Date:5/16/2023
435 Highland Ave
Salem MA 01970
What is the max letter/character height allowed?
EXTRA SPACE STORAGE # 3120Property ID:
Yes.
No higher than whichever of the following is lowest:
a. Twenty-five feet above sidewalk or finish grade;
b. The top of the sills of the first level of windows above the first story; or
c. The height of the building at the building line.
Yes.
Stamped engineering may be required.
Based on aggregate area of sign provisions herein; subject to review.
Yes.
https://www.salem.com/sites/g/files/vyhlif7986/f/uploads/sign_ordinance_worksheet_04-
16.pdf
Total # Wall Signs allowed per building elevation:
See above.
Beth Forrestal
Address:98 Washington Street 2nd Floor
3-5 weeks. Normal permitting times are not in effect during the pandemic. As cities learn to revamp the way
they do things, you can expect delays.
Sq Ft allowance for bldg. sides / rear:
What drawings & documents are required to file for the
permit?
Submit sign permit application using the permit portal.
Yes.
A sign review committee, comprised of the following members, shall be established for the purpose of
reviewing all signage proposed for the ECOD; Building Commissioner or designee; and City Planner or
designee; and representative of the Salem Redevelopment Authority.
1. The sign review committee shall review the size, location, type of material and design of all signs
located within an ECOD.
2. The sign review committee shall follow the Salem Sign Ordinance, except that the sign review
committee shall be allowed to limit the size of all signs within an ECOD to one-half (½) the size which is
allowed in the underlying zone.
3. Approval by a simple majority of this committee is required prior to a sign permit being granted by the
City.
Per Beth: If all is in order, the entire process can take up to 3 weeks to complete.
Page 1 of 4
6.)
7.)Are roof mounted signs allowed?
8.)Are raceways allowed?
9.)Other restrictions/comments:
7.)Does window vinyl need to be permitted, if so how much is allowed?
8.)Is the entire graphic calculated or just the company logo and name?
1.)
2.)
3.)
4.)
1.)
Does the ordinance restrict color, design or illumination?
FREESTANDING SIGNS
Formula for calculating freestanding sign sq. footage (Max Sq Footage- Primary & Secondary signs):
Wall signs are affixed parallel to the street wall and should be installed in the sign band
area above the store entrance. Wall signs should not obscure architectural details or sit in
front of windows on upper floors. Painted, raised letters, or a box sign are all possible
methods for wall signs. Simplicity and compatibility with the building architecture are
important considerations.
Wall signs shall not projects no more than 15 inches from the building surface.
Architectural lighting is recommended. Light sources should be shielded to prevent glare
from shining into neighboring windows or into the eyes of pedestrians and drivers. Only
finished and shielded fixtures should be used on building façades. The finish should
complement to sign and other façade elements.
Internally lighted signs are not recommended in the Entrance Corridors.
Internally lighted box signs, particularly with light colored backgrounds are not
recommended.
Signs shall be lighted only by continuous light, except that a warning sign or a sign
illuminated to show time and temperature may have intermittent illumination. Signs shall
remain stationary.
(a) Flashing lights or simulations of traffic signals or emergency vehicle lights shall not be
used on signs. In addition, red and green colored lights shall not be used when so placed
that they could obscure or be a hazard to the clear vision of traffic control signals viewed
from any point on an approaching public way or if, in the opinion of the building
inspector, such light would constitute a hazard.
(b) Spotlights or floodlights shall not be aimed so that any portion of the main beam can
be seen from a public way.
Projection restrictions?It projects no more than five feet from the building;
Other restrictions/comments:
The bottom of the sign is at least ten feet from grade and its top is no higher than whichever of the following is
lowest:
1. Twenty-five feet above sidewalk or finish grade;
2. The top of the sills of the first level of windows above the first story; or
3. The height of the building at the building line;
No exposed guy wires or turnbuckles.
WINDOW GRAPHICS
It is advisable to keep major signs out of windows. A limited amount of
lettering in small sizes is appropriate and effective within windows to describe
products, address, or hours of operation. These should be carefully organized
around the store entrance.
A permanent nonilluminated sign on the inside of the glass of a window,
provided that the total area of the sign does not exceed 30 percent of the
total glass area of windows appurtenant to the use to which the sign is
accessory, and provided that signs on ground floor windows be included in
calculating the total area of signs on a sign frontage.
Permit required.
See temporary signs.
Entire graphic.
PROJECTING SIGNS
How many are allowed (maximum)?There is no more than one such sign for each entrance door to a business establishment. The sign advertises a
use which occupies at least 18 feet of sign frontage;
Maximum sq footage per sign?
Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first
floor, freestanding signs, and directional signs:
Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by
0—99 2
100—399 2.5
400 and over 3
The area of the sign shall not exceed 24 square feet on either side, except that an additional ten square feet on
each face is allowed for a sign which incorporates a public service message device such as a time and
temperature sign.
No.
Per Beth: individual halo lit channel letters are okay in the ECOD as well as external
lighting.
N/A
Page 2 of 4
CODE RESEARCH
June 14, 2023 ∙ EXSS-MA001-R01 Page 4 of 9
2.)# F/S Signs allowed:
3.)Height Maximum:
4.)Set-back of sign from right-of-way or property line:
5.)Engineering required?
6.)Permit required for reface?
7.)Other restrictions/comments:
5.)Number Allowed:
6.)Illumination Allowed?
7.)Permit Required?:
1.)
2.)
3.)
4.)
5.)
6.)
7.)
Property I.D. #
1.)
2.)
3.)
4.)
5.)
6.)
Yes. Customer Logo Allowed:Shall bear no advertising.
No permit is required or temporary window signs.
Yes.
PRE-PERMIT SIGN INFO - Notes, continued EXTRA SPACE STORAGE # 3120
Variance document deadline?
A lot with a front lot line of 200 or more feet
may have two freestanding signs.Internal illumination allowed:
Internally lighted signs are not recommended
in the Entrance Corridors.
Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs:
Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by
0—99 2
100—399 2.5
400 and over 3
However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent signs.
If there are one or two uses on the lot, the area of each face does not exceed 65 square feet.
Variance cost?
Clearance from grade to sign:
See illumination restrictions.
Variance meeting dates?
https://www.salemma.gov/zoning-board-appeals/files/zoning-board-appeals-application-guide
How many sets?2 copies.
Variance documents required?
How is the sign area calculated?
Are logos factored into sign area?
$250 and up.
Variance time frame?2-4 months.
Applications will be accepted each month on a first come, first served basis. Once the monthly meeting
agenda is full, petitions will be carried over to the following month’s meeting. Petitioners are encouraged
to submit their applications as early as possible. See below.
DIRECTIONAL SIGNS
Directional signs necessary for public safety.Maximum Square Footage:12 square feet per face .
Cannot project into right of way; Cannot obstruct view. Subject to Site plan review.
The top of such sign is no higher than 25 feet
above sidewalk or finish grade.
How long can signs be up?
Does the ordinance restrict color, design or illumination?
VARIANCE INFORMATION
Signs shall not obstruct view. Subject to
review.
https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/boa_23_24_schedule_approved.pdf
How many signs per elevation?
Maximum Height:Not stipulated in the code. Subject to review.
What temporary sign types are allowed?
TEMPORARY BANNERS
Contractor sign: One sign.
Contractor sign: not exceeding 32 square feet in total area.
Temporary signs: affixed to windows, provided that their total area does not exceed 30 percent of the
window.
The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display
area of the sign, together with any backing different in color or material from the finish material of the
building face, without deduction for open space or other irregularities. Structural members not bearing
advertising matters hall not be included unless internally or decoratively lighted. Only one side of flat,
back-to-back signs need be included in calculating sign area.
Contractor sign:
Temporary signs pertaining to special sales or events
Contractor sign: On a lot where a building is actually under construction.
Temporary sign: No more than 15 days.
What is the max sign size area?
No permit shall be effective until the director of public services and the city electrician, for
illuminated signs, shall have filed with the city clerk a certification that such sign is securely
fastened so as not to endanger persons upon the sidewalk or street. A sign for which a permit
is required may be inspected periodically by the building inspector for compliance with this
article and other requirements of law.
Except for copy changes on signs with changeable letter panels, no on-premises sign shall be
reconstructed, extended, changed structurally or in content or replaced except in accordance
with this article.
Signs shall not obstruct view. Subject to review.
Page 3 of 4
7.)Likelihood of variance approval?
This code check is provided with the assumption that you will get the landlord / property owner approval. The information herein is limited to what the city has told us, and we cannot be
responsible if they do not inform us that a sign plan is in place. We strongly encourage you to check your lease for landlord criteria and to apply for permits before manufacturing a sign.
Sign criteria is reported as presented to us as of the "Completion Date". ETD is not responsible for changes in local sign code after the completion date, nor for the review process
interpretations, calculations or fees of local authorities. It is understood that a permit will be obtained prior to manufacture, if required by authorities. The recipient of this code check
understands and agrees to the following: This code check is not exclusive and should not be used in place of the definitions, prohibitions and exemptions of the ordinance. This code
check is good for the day on which it is completed only. Information contained herein is a guideline and should not in any way be taken as a permit approval. Signs should not be
produced until the permit has been issued. Zoning approval is often subject to interpretation that said official makes of the ordinance for their city/county/township; we cannot be held
responsible for verbal answers and interpretation. This code check is completed without the knowledge of specific project details and Expedite The Diehl LLC does not assume any
liability, we simply provide the code information based on the current code. 2023
MISC. NOTES
20%
https://library.municode.com/ma/salem/codes/code_of_ordinances?nodeId=PTIIICOOR_CH4AD_ARTIISIBI
https://library.municode.com/ma/salem/codes/zoning_ordinance?nodeId=S8.0SPDIRE_8.2ENCOOVDIEC
Design Guidelines
https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/sdg_all_pages_0.pdf
Overlay
Page 4 of 4
CODE RESEARCH
June 14, 2023 ∙ EXSS-MA001-R01 Page 5 of 9
SIGN INVENTORY
L#EXISTING RECOMMENDATION QTY
1 Pylon Panel 2
2 Letterset Letterset 1
3 Letterset Panel 1
4 None Letterset 1
SITE MAP
Surveyor:-
1
3
4
June 14, 2023 ∙ EXSS-MA001-R01 Page 6 of 9
Quantity Sign Sq.Ft.Illumination Face Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
EXISTING SIGN DETAILS:
Quantity Depth Sign Sq. Ft.Illumination Face
Mounting Fabrication
CONTEXT PHOTOS:
SURVEY NOTES:
Pylon Sign Cut Size for Face: 107.5”W x 93”H
EXSS-FPL-004-IL-SF-093H-X
Remove existing panel faces. Install new panels in existing cabinet. Paint existing cabinet and pole Extra
Space Storage Gray. Cabinet retainer to be repaired. RETROFIT WITH USLED.
Existing survey measurements to be confirmed. Technical survey required prior to production.
Existing: Recommendation: Pylon Panel
LOCATION1
FRONT VIEW
SCALE: NTS
SIDE VIEW
SCALE: NTS
0.188”
[5mm]
7’-9”
[2362mm]
8’-11.5”
[2731mm]
3’-1.11”
[943mm]
7’-9”
[2362mm]
8’-11.5”
[2731mm]
NIGHT VIEW
LOCATION 1
2 69.4 Face Lit Single -
Existing Frame Flat Polycarbonate Panel
1 Unknown 69.4 Face Lit Double
Unknown Fabricated Pylon
IMAGING/SCALING IS ESTIMATED
NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES
June 14, 2023 ∙ EXSS-MA001-R01 Page 7 of 9
Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
EXISTING SIGN DETAILS:
Quantity Depth Sign Sq. Ft.Illumination
Mounting Fabrication
NO PHOTO AVAILABLE
CONTEXT PHOTOS:
SURVEY NOTES:
Letter “L” is 48” tall.
EXSS-LTR-505-IL-RW-053H
Remove existing letterset. Install new letterset in its place. Existing wall color needs to be determined
prior to production. Complete restoration and paint in repair area shown (See wall repair
guidelines).
Existing: Recommendation: Letterset Letterset
LOCATION2
FRONT VIEW
SCALE: NTS
22’-3.45”
[6793mm]
14’-8.74”
[4489mm]
37’-9.79”
[11526mm]
SIDE VIEW
SCALE: NTS
5”
[127mm]
4’-5.26”
[1353mm]
3’-6”
[1067mm]2’-6.74”
[7891mm]
39’-0”
[11887mm]
7’-0”
[2134mm]
LOCATION 2
1 167.84 Face Lit 254
Raceway ESS-ILL42GB-RW
1 Unknown 273 Face Lit
Raceway Channel Letterset on Raceway
NIGHT VIEW
NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES
Repair Area
254 SQ.FT.
June 14, 2023 ∙ EXSS-MA001-R01 Page 8 of 9
Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
EXISTING SIGN DETAILS:
Quantity Depth Sign Sq. Ft.Illumination
Mounting Fabrication
NO PHOTO AVAILABLE
CONTEXT PHOTOS:
SURVEY NOTES:
EXSS-WPL-501-IL-SF-061H
Remove existing letterset. Install new letterset in its place. Existing wall color needs to be determined
prior to production. Complete restoration and paint in repair area shown (See wall repair
guidelines).
Existing: Recommendation: Letterset Panel
LOCATION3
FRONT VIEW
SCALE: NTS
SIDE VIEW
SCALE: NTS
1’-6”
[457mm]
5’-1.04”
[1550mm]
11’-3”
[3429mm]
3’-8.8”
[1138mm]
9’-5.09”
[2872mm]
7’-0”
[2134mm]
7’-0”
[2134mm]
NIGHT VIEW
LOCATION 3
1 57.2 Face Lit 96
Brackets ESS-W57
1 Unknown 49 Face Lit
Raceway Channel Letterset on Raceway
NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES
Repair Area
96 SQ.FT.
June 14, 2023 ∙ EXSS-MA001-R01 Page 9 of 9
Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
NO PHOTO AVAILABLE
CONTEXT PHOTOS:
SURVEY NOTES:
No survey dimensions provided for canopy.
EXSS-LTR-585-IL-RW-014H
Install new letterset on top of canopy.
Raceway color: SW7069 Iron Ore
Existing canopy dimensions and color needs to be determined prior to production.
Existing: Recommendation: None Letterset
LOCATION4
FRONT VIEW
SCALE: NTS
SIDE VIEW
SCALE: NTS
3”
[76mm]
3’-9.5”
[1156mm]
1’-2”
[356mm]
11.5”
[292mm]
Raceway painted to match
SW7069 Iron Ore
LOCATION 4
1 4.42 Face Lit -
Raceway Channel Letterset
NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES
NIGHT VIEW
IMAGING/SCALING IS ESTIMATED
5 Technology Circle ∙ Columbia, SC ∙ 29203 ∙ USA
+1.803.926.7926 P ∙ +1.803.926.8412 F
www.colite.com
SITE DOCUMENT
August 22, 2023
EXSS-MA001-R04
# 3120
435 Highland Ave
Salem, MA 01970
August 22, 2023 ∙ EXSS-MA001-R04 Page 2 of 10
Corrugated Drywall
Brick
Wood, Marble, Glass, and Granite
Concrete
Sidings
Stucco and EIFS
Wallpaper
Exterior Interior
To be discussed with client. End result should ensure holes are filled or patched
prior to installing new sign.
Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex
caulk. Prep and paint wall to a Level 4 finish with approved paint color (SHERWIN
WILLIAMS or BENJAMIN MOORE).
Holes to be filled with QUICKRETE mortar repair sealant or paintable caulk.
Pressure wash wall.To be discussed with client prior to budget presentation.
Holes to be filled with QUICKRETE concrete repair sealant. Pressure wash wall.
Patch holes with pre-approved painted aluminum.
Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex caulk.
Prep and paint wall with approved paint color (SHERWIN WILLIAMS or BENJAMIN
MOORE).
* Paint must cure for a minimum of 48 hours prior to graphics installation. Gassing and/or peeling of graphic can occur otherwise.
* Electrical is to be brought to signage area prior to sign installation by GC or owner.
Wallpaper to be removed and reapplied. PM to consult with client as they may
have access to matching wallpaper.
WALL REPAIR GUIDELINES
August 22, 2023 ∙ EXSS-MA001-R04 Page 3 of 10
A.)Project Name:
B.)Street Address:
C.)Town / City / State / Zip:
D.)Contact for Permit/Zoning:
E.)Contact Telephone:
Contact E-Mail if available:
F.)Jurisdiction: City/Town
or, County of:
G.)Zoning Classification for property:
H.)Is there a Master Sign Plan?
I.)Is a permit required?
J.)
K.)How long is the permit process?
L.)What are the fees for a sign permit?
M.)Is engineering needed for wall signs?
N.)Does engineering require a PE stamp?
Are hard copies needed? How many?
O.)Is landlord approval required?
P.) Legal Description Required for permit?
Q.)Plat/Site Plan required for permit?
R.)Certificate of Occupancy required for permit?
S.)Any special design reviews required (explain)?
If yes, projected processing time?
1.)
2.)
3.)
4.)
5.)
EXTRA SPACE STORAGE # 3120
$25 plus $11.00 per $1000
(978) 619-5685
City of Salem
Salem, MA 01970City, ST Zip:
Yes.
Yes.
bforrestal@salem.com
How is the sign area calculated?
The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display area of
the sign, together with any backing different in color or material from the finish material of the building face,
without deduction for open space or other irregularities. Structural members not bearing advertising matters
hall not be included unless internally or decoratively lighted. Only one side of flat, back-to-back signs need be
included in calculating sign area.
B2; Business Highway; Entrance Corridor Overlay (Requires additional reviews; See below)
Per Beth: Follow the Design Guidelines and the code.
ATTACHED SIGNS (WALL SIGNS & AWNING/CANOPY SIGNS)
Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first
floor, freestanding signs, and directional signs:
Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by
0—99 2
100—399 2.5
400 and over 3
However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent
signs.
Formula for calculating wall sign square
footage (Max. Sq. Footage - Primary &
Secondary signs):
PRE-PERMIT SIGN INFO
Date:5/16/2023
435 Highland Ave
Salem MA 01970
What is the max letter/character height allowed?
EXTRA SPACE STORAGE # 3120Property ID:
Yes.
No higher than whichever of the following is lowest:
a. Twenty-five feet above sidewalk or finish grade;
b. The top of the sills of the first level of windows above the first story; or
c. The height of the building at the building line.
Yes.
Stamped engineering may be required.
Based on aggregate area of sign provisions herein; subject to review.
Yes.
https://www.salem.com/sites/g/files/vyhlif7986/f/uploads/sign_ordinance_worksheet_04-
16.pdf
Total # Wall Signs allowed per building elevation:
See above.
Beth Forrestal
Address:98 Washington Street 2nd Floor
3-5 weeks. Normal permitting times are not in effect during the pandemic. As cities learn to revamp the way
they do things, you can expect delays.
Sq Ft allowance for bldg. sides / rear:
What drawings & documents are required to file for the
permit?
Submit sign permit application using the permit portal.
Yes.
A sign review committee, comprised of the following members, shall be established for the purpose of
reviewing all signage proposed for the ECOD; Building Commissioner or designee; and City Planner or
designee; and representative of the Salem Redevelopment Authority.
1. The sign review committee shall review the size, location, type of material and design of all signs
located within an ECOD.
2. The sign review committee shall follow the Salem Sign Ordinance, except that the sign review
committee shall be allowed to limit the size of all signs within an ECOD to one-half (½) the size which is
allowed in the underlying zone.
3. Approval by a simple majority of this committee is required prior to a sign permit being granted by the
City.
Per Beth: If all is in order, the entire process can take up to 3 weeks to complete.
Page 1 of 4
6.)
7.)Are roof mounted signs allowed?
8.)Are raceways allowed?
9.)Other restrictions/comments:
7.)Does window vinyl need to be permitted, if so how much is allowed?
8.)Is the entire graphic calculated or just the company logo and name?
1.)
2.)
3.)
4.)
1.)
Does the ordinance restrict color, design or illumination?
FREESTANDING SIGNS
Formula for calculating freestanding sign sq. footage (Max Sq Footage- Primary & Secondary signs):
Wall signs are affixed parallel to the street wall and should be installed in the sign band
area above the store entrance. Wall signs should not obscure architectural details or sit in
front of windows on upper floors. Painted, raised letters, or a box sign are all possible
methods for wall signs. Simplicity and compatibility with the building architecture are
important considerations.
Wall signs shall not projects no more than 15 inches from the building surface.
Architectural lighting is recommended. Light sources should be shielded to prevent glare
from shining into neighboring windows or into the eyes of pedestrians and drivers. Only
finished and shielded fixtures should be used on building façades. The finish should
complement to sign and other façade elements.
Internally lighted signs are not recommended in the Entrance Corridors.
Internally lighted box signs, particularly with light colored backgrounds are not
recommended.
Signs shall be lighted only by continuous light, except that a warning sign or a sign
illuminated to show time and temperature may have intermittent illumination. Signs shall
remain stationary.
(a) Flashing lights or simulations of traffic signals or emergency vehicle lights shall not be
used on signs. In addition, red and green colored lights shall not be used when so placed
that they could obscure or be a hazard to the clear vision of traffic control signals viewed
from any point on an approaching public way or if, in the opinion of the building
inspector, such light would constitute a hazard.
(b) Spotlights or floodlights shall not be aimed so that any portion of the main beam can
be seen from a public way.
Projection restrictions?It projects no more than five feet from the building;
Other restrictions/comments:
The bottom of the sign is at least ten feet from grade and its top is no higher than whichever of the following is
lowest:
1. Twenty-five feet above sidewalk or finish grade;
2. The top of the sills of the first level of windows above the first story; or
3. The height of the building at the building line;
No exposed guy wires or turnbuckles.
WINDOW GRAPHICS
It is advisable to keep major signs out of windows. A limited amount of
lettering in small sizes is appropriate and effective within windows to describe
products, address, or hours of operation. These should be carefully organized
around the store entrance.
A permanent nonilluminated sign on the inside of the glass of a window,
provided that the total area of the sign does not exceed 30 percent of the
total glass area of windows appurtenant to the use to which the sign is
accessory, and provided that signs on ground floor windows be included in
calculating the total area of signs on a sign frontage.
Permit required.
See temporary signs.
Entire graphic.
PROJECTING SIGNS
How many are allowed (maximum)?There is no more than one such sign for each entrance door to a business establishment. The sign advertises a
use which occupies at least 18 feet of sign frontage;
Maximum sq footage per sign?
Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first
floor, freestanding signs, and directional signs:
Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by
0—99 2
100—399 2.5
400 and over 3
The area of the sign shall not exceed 24 square feet on either side, except that an additional ten square feet on
each face is allowed for a sign which incorporates a public service message device such as a time and
temperature sign.
No.
Per Beth: individual halo lit channel letters are okay in the ECOD as well as external
lighting.
N/A
Page 2 of 4
CODE RESEARCH
August 22, 2023 ∙ EXSS-MA001-R04 Page 4 of 10
2.)# F/S Signs allowed:
3.)Height Maximum:
4.)Set-back of sign from right-of-way or property line:
5.)Engineering required?
6.)Permit required for reface?
7.)Other restrictions/comments:
5.)Number Allowed:
6.)Illumination Allowed?
7.)Permit Required?:
1.)
2.)
3.)
4.)
5.)
6.)
7.)
Property I.D. #
1.)
2.)
3.)
4.)
5.)
6.)
Yes. Customer Logo Allowed:Shall bear no advertising.
No permit is required or temporary window signs.
Yes.
PRE-PERMIT SIGN INFO - Notes, continued EXTRA SPACE STORAGE # 3120
Variance document deadline?
A lot with a front lot line of 200 or more feet
may have two freestanding signs.Internal illumination allowed:
Internally lighted signs are not recommended
in the Entrance Corridors.
Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs:
Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by
0—99 2
100—399 2.5
400 and over 3
However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent signs.
If there are one or two uses on the lot, the area of each face does not exceed 65 square feet.
Variance cost?
Clearance from grade to sign:
See illumination restrictions.
Variance meeting dates?
https://www.salemma.gov/zoning-board-appeals/files/zoning-board-appeals-application-guide
How many sets?2 copies.
Variance documents required?
How is the sign area calculated?
Are logos factored into sign area?
$250 and up.
Variance time frame?2-4 months.
Applications will be accepted each month on a first come, first served basis. Once the monthly meeting
agenda is full, petitions will be carried over to the following month’s meeting. Petitioners are encouraged
to submit their applications as early as possible. See below.
DIRECTIONAL SIGNS
Directional signs necessary for public safety.Maximum Square Footage:12 square feet per face .
Cannot project into right of way; Cannot obstruct view. Subject to Site plan review.
The top of such sign is no higher than 25 feet
above sidewalk or finish grade.
How long can signs be up?
Does the ordinance restrict color, design or illumination?
VARIANCE INFORMATION
Signs shall not obstruct view. Subject to
review.
https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/boa_23_24_schedule_approved.pdf
How many signs per elevation?
Maximum Height:Not stipulated in the code. Subject to review.
What temporary sign types are allowed?
TEMPORARY BANNERS
Contractor sign: One sign.
Contractor sign: not exceeding 32 square feet in total area.
Temporary signs: affixed to windows, provided that their total area does not exceed 30 percent of the
window.
The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display
area of the sign, together with any backing different in color or material from the finish material of the
building face, without deduction for open space or other irregularities. Structural members not bearing
advertising matters hall not be included unless internally or decoratively lighted. Only one side of flat,
back-to-back signs need be included in calculating sign area.
Contractor sign:
Temporary signs pertaining to special sales or events
Contractor sign: On a lot where a building is actually under construction.
Temporary sign: No more than 15 days.
What is the max sign size area?
No permit shall be effective until the director of public services and the city electrician, for
illuminated signs, shall have filed with the city clerk a certification that such sign is securely
fastened so as not to endanger persons upon the sidewalk or street. A sign for which a permit
is required may be inspected periodically by the building inspector for compliance with this
article and other requirements of law.
Except for copy changes on signs with changeable letter panels, no on-premises sign shall be
reconstructed, extended, changed structurally or in content or replaced except in accordance
with this article.
Signs shall not obstruct view. Subject to review.
Page 3 of 4
7.)Likelihood of variance approval?
This code check is provided with the assumption that you will get the landlord / property owner approval. The information herein is limited to what the city has told us, and we cannot be
responsible if they do not inform us that a sign plan is in place. We strongly encourage you to check your lease for landlord criteria and to apply for permits before manufacturing a sign.
Sign criteria is reported as presented to us as of the "Completion Date". ETD is not responsible for changes in local sign code after the completion date, nor for the review process
interpretations, calculations or fees of local authorities. It is understood that a permit will be obtained prior to manufacture, if required by authorities. The recipient of this code check
understands and agrees to the following: This code check is not exclusive and should not be used in place of the definitions, prohibitions and exemptions of the ordinance. This code
check is good for the day on which it is completed only. Information contained herein is a guideline and should not in any way be taken as a permit approval. Signs should not be
produced until the permit has been issued. Zoning approval is often subject to interpretation that said official makes of the ordinance for their city/county/township; we cannot be held
responsible for verbal answers and interpretation. This code check is completed without the knowledge of specific project details and Expedite The Diehl LLC does not assume any
liability, we simply provide the code information based on the current code. 2023
MISC. NOTES
20%
https://library.municode.com/ma/salem/codes/code_of_ordinances?nodeId=PTIIICOOR_CH4AD_ARTIISIBI
https://library.municode.com/ma/salem/codes/zoning_ordinance?nodeId=S8.0SPDIRE_8.2ENCOOVDIEC
Design Guidelines
https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/sdg_all_pages_0.pdf
Overlay
Page 4 of 4
CODE RESEARCH
August 22, 2023 ∙ EXSS-MA001-R04 Page 5 of 10
SIGN INVENTORY
L#EXISTING RECOMMENDATION QTY
1 Pylon Panel 2
2 Letterset Letterset 1
3 Letterset Panel 1
4 None Letterset 1
SITE MAP
Surveyor:-
1
3
4
August 22, 2023 ∙ EXSS-MA001-R04 Page 6 of 10
Quantity Sign Sq.Ft.Illumination Face Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
EXISTING SIGN DETAILS:
Quantity Depth Sign Sq. Ft.Illumination Face
Mounting Fabrication
CONTEXT PHOTOS:
SURVEY NOTES:
Pylon Sign Visual Opening for Face: 8’-8.38” W x 5’-9.5” H.
Cut size for face is 8’-11.5” W x 6’-1” H.
Important: sign cabinet is rusting and is not secure.
EXSS-RFC-004-IL-DF-073H-X
Remove existing panel faces. Install new panels in existing cabinet. Paint existing cabinet and pole Extra
Space Storage Gray. Cabinet retainer to be repaired. RETROFIT WITH USLED.
Existing: Recommendation: Pylon Panel
LOCATION1
FACE 1
SCALE: NTS
SIDE VIEW
SCALE: NTS
FACE 2
SCALE: NTS
6’-1”
[1854mm]
8’-11.5”
[2731mm]
5’-9.5”
[1765mm]
Visual Opening
8’-8.38”
[2651mm]
Visual Opening
0.188”
[5mm]
NIGHT VIEW
LOCATION 1
1 54.5 Face Lit Double -
Existing Frame Flat Polycarbonate Panel
1 Unknown 54.5 Face Lit Double
Unknown Fabricated Pylon
August 22, 2023 ∙ EXSS-MA001-R04 Page 7 of 10
Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
EXISTING SIGN DETAILS:
Quantity Depth Sign Sq. Ft.Illumination
Mounting Fabrication
NO PHOTO AVAILABLE
CONTEXT PHOTOS:
SURVEY NOTES:
Letter “L” is 48” tall.
Wall color is RVW White.
EXSS-LTR-020-IL-EX-053H-X
EXSS-WPL-006-NL-SF-072H-X
Remove existing letterset. Install new letterset in its place. Complete restoration and paint in repair
area shown (See wall repair guidelines). Custom per client request.
Existing: Recommendation: Letterset Letterset
LOCATION2
FRONT VIEW
SCALE: NTS
SIDE VIEW
SCALE: NTS
22’-3.45”
[6793mm]
14’-8.74”
[4489mm]
4’-5.26”
[1353mm]
2’-6.74”
[7891mm]
37’-9.79”
[11526mm]
5”
[127mm]
3’-6”
[1067mm]
Seam
39’-0”
[11887mm]
2”
[51mm]
6’-0”
[1829mm]
wall panel to match existing
wall color, RVW White
39’-0”
[11887mm]
7’-0”
[2134mm]
LOCATION 2 Option A
1 167.84 Halo Lit 254
Studs/Brackets Halo Lit Letterset with Backer Panel
1 Unknown 273 Face Lit
Raceway Channel Letterset on Raceway
NIGHT VIEW
Paint Area
254 SQ.FT.
August 22, 2023 ∙ EXSS-MA001-R04 Page 8 of 10
Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
EXISTING SIGN DETAILS:
Quantity Depth Sign Sq. Ft.Illumination
Mounting Fabrication
NO PHOTO AVAILABLE
CONTEXT PHOTOS:
SURVEY NOTES:
Letter “L” is 48” tall.
Wall color is RVW White.
EXSS-LTR-021-IL-EX-053H-X
EXSS-WPL-007-NL-SF-072H-X
Remove existing letterset. Install new letterset in its place. Complete restoration and paint in repair
area shown (See wall repair guidelines). Custom per client request.
Existing: Recommendation: Letterset Letterset
FRONT VIEW
SCALE: NTS
SIDE VIEW
SCALE: NTSwall panel to match: MP46295
to Match SW6923 Festival Green
22’-3.45”
[6793mm]
14’-8.74”
[4489mm]
4’-5.26”
[1353mm]
2’-6.74”
[7891mm]
37’-9.79”
[11526mm]
Seam
39’-0”
[11887mm]
5”
[127mm]2”
[51mm]
6’-0”
[1829mm]
3’-6”
[1067mm]
39’-0”
[11887mm]
7’-0”
[2134mm]
LOCATION 2 Option B
1 167.84 Halo Lit 254
Studs/Brackets Halo Lit Letterset with Backer Panel
1 Unknown 273 Face Lit
Raceway Channel Letterset on Raceway
NIGHT VIEW
Paint Area
254 SQ.FT.
August 22, 2023 ∙ EXSS-MA001-R04 Page 9 of 10
Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
EXISTING SIGN DETAILS:
Quantity Depth Sign Sq. Ft.Illumination
Mounting Fabrication
NO PHOTO AVAILABLE
CONTEXT PHOTOS:
SURVEY NOTES:
Existing electrical behind sheet metal.
Wall color is RVW White
EXSS-WPL-004-IL-SF-061H-X
Remove existing letterset. Install new letterset in its place. Complete restoration and paint in repair
area shown (See wall repair guidelines). Custom per client request.
Existing: Recommendation: Letterset Panel
LOCATION3
FRONT VIEW
SCALE: NTS
SIDE VIEW
SCALE: NTS
5’-1.04”
[1550mm]
11’-3”
[3429mm]
3’-8.8”
[1138mm]
9’-5.09”
[2872mm]
1’-0”
[306mm]
3”
[76mm]
7’-0”
[2134mm]
7’-0”
[2134mm]
NIGHT VIEW
LOCATION 3
1 57.2 Halo Lit 96
Brackets Fabricated Wall Panel with Halo Lit Letterset
1 Unknown 49 Face Lit
Raceway Channel Letterset on Raceway
Paint Area
96 SQ.FT.
August 22, 2023 ∙ EXSS-MA001-R04 Page 10 of 10
Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft.
Mounting Fabrication
RECOMMENDATION DETAILS:
INSTALLATION/REPAIR NOTES:
PART #:
SIGN DETAIL:
NO PHOTO AVAILABLE
CONTEXT PHOTOS:
SURVEY NOTES:
Color of canopy is Pantone 286 CP.
Canopy is 3’-0” deep.
Doors are 2’-3” W x 6’-6.25” H.
EXSS-LTR-018-NL-RW-014H-X
Install new letterset on top of canopy.
Existing: Recommendation: None Letterset
LOCATION5
FRONT VIEW
SCALE: NTS
SIDE VIEW
SCALE: NTS
3’-9.5”
[1156mm]
1’-2”
[356mm]
11.5”
[292mm]
0.5”
[13mm]
Raceway painted
Cool Grey 11
28’-1.63”
[8576mm]
6”
[152mm]
LOCATION 4
1 4.42 None -
Raceway Flat Cut Out Letterset
11'-3"
3428.94mm
5'-1 1/16"
1550.42mm
1 11/16"
42.31mm
1'-1 3/8"
340.22mm
8'-11 15/16"
2741.07mm
3'-8 11/16"
1135.78mm
3'-0 1/4"
921.01mm
FRONT VIEW
SCALE: 1 : 16
V1
V3
7"
178.05mm
SIDE VIEW
SCALE: 1 : 16
P2
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-WPL-501-IL-SF-061H
OVERALL
EXTRA SPACE STORAGE
VARIOUS
6/22/2023
WALL PANEL
TEL
INITIAL CREATION2/22/2023TELA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.
3M 3630-106 Green(V1)
3M 3630-22 Black(V3)
MP38501 to match SW7067 Cityscape(P2)
SHEET 1 OF 4
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:24
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
11'-3"
3428.94mm
1'-4"
406.40mm
2'-8"
812.80mm
VIEW
SCALE: 1 : 22
ANG1
SHT2
ELC3
PWR1
ANG1
SHT1
FLX1
SHT2
HDW1
EXTR1
HDW2
HDW3
HDW4
EXTR2
EXTR3
ELC1
ELC2
ANG1
SCH1
SHT3
SHT4
INSTALLATION BILL OF MATERIALS
ITEM #PART #DESCRIPTION
HDW2 HW-00123 3/8-16 x 12" SS ALL THREAD STUD
HDW3 HW-00085 3/8 Stainless Steel Flat Washer
HDW4 HW-00053 3/8-16 Stainless Steel Finished Hex Nut
ANG2 AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE
SCH1 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE
MANUFACTURING BILL OF MATERIALS
ITEM #PART #DESCRIPTION
FLX1 3M-PANAGRAPHICS 3M PANAGRAPHICSIII FLEXIBLE SUBSTRATE 126" X 164'
(FLEXFACE)
SHT1 AL-SH-125-72-144 .125 x 72 x 144 ALUMINUM SHEET
SHT2 AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET ( BREAKFORM 2" X 3.5"
CHANNEL)
SHT3 AL-SH-090-48-120 .090 x 48 x 120 ALUMINUM SHEET (METAL TRIMCAP)
SHT4 AL-SH-063-60-120 .063 x 60 x 120 ALUMINUM SHEET (METAL TRIMCAP)
ANG1 AL-EX-125-2-2-24-ANGL-S .125 X 2 X 2 X 24' ALUMINUM STRUCTURAL ANGLE
EXTR1 CU-EX-00004 SIGNCOMP 2121 Flat Bleed Retro Frame Cover
EXTR2 EL-EC-00070 SIGNCOMP #5360 BLACK PLASTIC TENSION CLIPS
EXTR3 CU-EX-SIGNCO-2107 SIGNCOMP 2107 FLAT BLEED RETRO FRAME II
LED1 USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE
PWR1 USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60WELC1HW-00063 1/2" Conduit Lock NutELC2EL-EC-00077 WALLBUSTER 14"L x 1/2" DIA. PAIGE ELECTRIC
ELC3 EL-EC-00071 Transco Toggle Disconnect Switch 20AMP
HDW1 HW-00035 Hinge Screw 5178
ELC3 EL-EC-00071 Transco Toggle Disconnect Switch 20AMP
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-WPL-501-IL-SF-061H
SECTION DETAIL
EXTRA SPACE STORAGE
VARIOUS
6/22/2023
WALL PANEL
TEL
INITIAL CREATION6/22/2023TELA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.SHEET 2 OF 4
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:16
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
MANUFACTURING BILL OF MATERIALS
PART #DESCRIPTION QTY.
3M-PANAGRAPHICS 3M PANAGRAPHICSIII FLEXIBLE SUBSTRATE 126" X
164' (FLEXFACE)12 LF
AL-SH-125-72-144 .125 x 72 x 144 ALUMINUM SHEET 53 SF
AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET ( BREAKFORM 2" X
3.5" CHANNEL)25 SF
AL-SH-090-48-120 .090 x 48 x 120 ALUMINUM SHEET (METAL TRIMCAP)25 SF
AL-SH-063-60-120 .063 x 60 x 120 ALUMINUM SHEET (METAL TRIMCAP)25 SF
AL-EX-125-2-2-24-ANGL-S .125 X 2 X 2 X 24' ALUMINUM STRUCTURAL ANGLE 16 LF
CU-EX-00004 SIGNCOMP 2121 Flat Bleed Retro Frame Cover 28 LF
EL-EC-00070 SIGNCOMP #5360 BLACK PLASTIC TENSION CLIPS A/R
CU-EX-SIGNCO-2107 SIGNCOMP 2107 FLAT BLEED RETRO FRAME II 28 LF
USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE 199 EA
USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 5 EAHW-00063 1/2" Conduit Lock Nut 1 EAEL-EC-00077 WALLBUSTER 14"L x 1/2" DIA. PAIGE ELECTRIC 1 EA
EL-EC-00071 Transco Toggle Disconnect Switch 20AMP 1 EA
HW-00035 Hinge Screw 5178 A/R
INSTALLATION BILL OF MATERIALS
PART #DESCRIPTION QTY.
HW-00123 3/8-16 x 12" SS ALL THREAD STUD 8 EA
HW-00085 3/8 Stainless Steel Flat Washer 16 EA
HW-00053 3/8-16 Stainless Steel Finished Hex Nut 16 EA
AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE 22 LF
AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 10 LF
TOUCHUP-PAINT TOUCH UP PAINT (P2)1 EA
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-WPL-501-IL-SF-061H
B.O.M
EXTRA SPACE STORAGE
VARIOUS
6/22/2023
WALL PANEL
TEL
INITIAL CREATION6/2/2023TELA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.SHEET 3 OF 4
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:16
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY
DESCRIPTIONDATEBYREV
REVISIONS
11X17
PRINTDRAWN BY
DATE
LOCATION
CUSTOMER
TITLE
SIGN TYPE
DRAWING NUMBER
THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE.
P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE
SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT
EXSS-WPL-501-IL-SF-061H
Sheet4
VARIOUS
INITIAL CREATIONA
C
B
E
D
F
G
J
I
H
NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN.
NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.SHEET 4 OF 4
THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS
VIEWS WITH SCALES DIFFERENT
THAN THE STATED SHEET SCALE WILL
DISPLAY SPECIFICALLY IN THAT VIEW
LABEL.
DRAWING VIEWS SCALE CHART
SHEET SCALE: 1:16
3/32" = 1'0"
1-1/2" = 1'0"
3" = 1'0"
1" = 1'0"
1/16" = 1'0"
1/4" = 1'0"
2" = 1'0"
1/2" = 1'0"
1/8" = 1'0"
4" = 1'0"
3/16" = 1'0"
3/8" = 1'0"
3/4" = 1'0"
1" = 1'0"
6" = 1'0"
1:192
1:128
1:96
1:64
1:48
1:32
1:24
1:16
1:12
1:8
1:6
1:4
1:3
1:2
1:1
UL NOTE
THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY