Loading...
435-443 HIGHLAND AVENUE - SIGN PERMIT - EXTRASPACE STORAGECity of Salem Sign Permit Application Worksheet Zoning (res/non-res)B2 nonresidential Multiplier Entrance Corridor (Y/N)Y building distance from street center if entrance corridor Lot frontage 345 feet <100 feet 2.00 1.00 Building or tenant frontage 285.00 feet 100-399 feet 2.50 1.25 # of businesses on site 1 >400 feet 3.00 1.50 Bldng dist from street center <100 feet feet Multiplier 1 Building and Blade Signs Building Sign Area maximum area permitted 285.00 sq ft =building frontage x multiplier if non conform in res zone=1/2 of above total proposed sign area 228.82 sq ft Blade Sign Area Wall Sign 1 167.85 sq ft width 447.60 inches height 54.00 inches Wall Sign 2 57.38 sq ft width 135.00 inches height 61.20 inches Awning 3.59 sq ft width 45.00 inches height 11.50 inches Freestanding Signs NONE maximum of 24 sq ft per side maximum area permitted 32.50 sq ft (per side)(12 sq ft per side in entry corridor) maximum # of signs permitted 2 signs 24 (or 12) counts toward max area maximum height permitted 12.50 ft tall Window Decal sign 1 proposed sign area 54.50 sq ft length 107.50 inches height 73.00 inches Application meets guidelines set forth in the Salem Sign Ordinance Y Recommend approval Y Freestanding Signs: Maximum Number, Area and Height Lot frontage < 200 feet Businesses on site 1 or 2 3 or more Non-residential 1 sign 1 sign 65 sq ft 125 sq ft per side 25 ft tall 30 ft tall Entry corridor 1 sign 1 sign 32.5 sq ft.62.5 sq ft per side 12.5 ft tall 15 ft tall If lot frontage is >200 feet, then 2 signs with sq ft and height for each applies. maximum of 20% of window dt; 30% elsewhere 24-Jul-23 ExtraSpace Storage 435-443 Highland Avenue Notes: Freestanding sign is a refacing of an existing freestanding sign that is illuminated. The sign application meets the size and lighting standards of the zoning code. 37'-7 1/16" 11457mm 22'-5 7/8" 6855mm 14'-9 11/16" 4513mm 2'-7 1/16" 788mm 3'-6 7/16" 1077mm 4'-5 13/16" 1366mm 6 1/2" 165mm 39'-0" 11887mm 1'-8 1/16" 509mm 6'-0" 1829mm 8 1/4" 210mm 4 3/4" 120mm A FRONT ELEVATION SEE EXSS-WPL-007-NL-SF-072H-X FOR DETAILS P5 5" 127mm 2" 51mm 8" 203mm SIDE ELEVATION P4 ISOMETRIC VIEW TOP ELEVATION R2 9/16" 65mm R2 3/16" 56mm 2 15/16" 75mm 2 3/8" 60mm DETAIL A SCALE: 1 : 8 V2 V3 Letterset Details NIGHT VIEW DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-021-IL-EX-053H-X EXTRA SPACE STORAGE EXSS-MA001 9/14/2023 Letterset HMD INITIAL CREATION9/14/2023HMDA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-20 WHITE(V2) 3M 3630-22 BLACK(V3) MP 923SP SATIN BLACK MP N202 SATIN WHITE (P4) (P5) SHEET 1 OF 3 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY COL1 POL1 SHT1 LED1 BUS1 HDW3 WIR1 HDW4 HDW1 B HDW6 A SECTION DETAIL (WITH SPACERS) - CORRUGATED METAL BUILDINGSCALE: N.T.S. A B PAINTED TO MATCH RETURNS SPACERS PAINTED TO MATCH BUILDING COLOR RVT1 HDW5 P5 P4 1" 25 1/4" 6 1 3/4" 44 11/16" 17 3/8" 10 3/16" 5 2" 51 2 3/4" 70 1" 25 1" 25 3/16" 5 SHT1 BRACE ISO VIEW SCALE: N.T.S.BRACE - TOP VIEW SCALE: N.T.S. BRACE - RIGHT SIDE VIEW SCALE: N.T.S. 5"[127mm] Corrugated Metal with Spacers Mounting MANUFACTURING BILL OF MATERIALS ITEM #PART #DESCRIPTION COL1 AL-SH-063-48-120 .063 x 48 x 120 ALUMINUM SHEET SHT1 AL-SH-125-60-120 .125 x 60 x 120 ALUMINUM SHEET POL1 PCLEA-177-60-120 .177 x 60 x 120 CLEAR POLYCARBONATE HDW1 HW-00220 #8 X 1" HEX WASHER HEAD SELF-DRILLING SCREW ZINC RVT1 HW-00109 Blind Rivet 3/16"x5/8" LED1 USLED-PXL2-2-12-W US LED PXL2-2-12-2 1.5 MODULES/FT 1260/CASE BUS1 EL-EC-00049 Arlington 4400 bushing HDW3 HW-00059 3/8" NUTCERT INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION WIR1 EL-EC-00001 16-2 STR SHLD CMP/CL3P WIRE PWS1 USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 10/CASE HDW4 HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW HDW5 HW-00085 3/8 Stainless Steel Flat Washer HDW6 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE ANG1 AL-EX-375-4-6-25-ANGLE 3/8" X 4 X 6 X 25FT ALUM ANGLE DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-021-IL-EX-053H-X EXTRA SPACE STORAGE EXSS-MA001 9/14/2023 Letterset HMD INITIAL CREATION9/14/2023HMDA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-20 WHITE(V2) 3M 3630-22 BLACK(V3) MP 923SP SATIN BLACK MP N202 SATIN WHITE (P4) (P5) SHEET 2 OF 3 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY Purchasing BOM PURCHASING BOM MANUFACTURING BILL OF MATERIALS PART #DESCRIPTION QTY. HW-00220 #8 X 1" HEX WASHER HEAD SELF-DRILLING SCREW ZINC A/R HW-00109 Blind Rivet 3/16"x5/8"A/R AL-SH-063-48-120 .063 x 48 x 120 ALUMINUM SHEET TBD LF AL-SH-125-60-120 .125 x 60 x 120 ALUMINUM SHEET TBD SF PCLEA-177-60-120 .177 x 60 x 120 CLEAR POLYCARBONATE TBD LF USLED-PXL2-2-12-W US LED PXL2-2-12-2 1.5 MODULES/FT 1260/CASE TBD EA EL-EC-00049 Arlington 4400 bushing 17 EA HW-00059 3/8" NUTCERT 51 EA INSTALLATION BILL OF MATERIALS PART #DESCRIPTION QTY. EL-EC-00001 16-2 STR SHLD CMP/CL3P WIRE 170 LF USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 10/CASE TBD EA HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW 51 EA HW-00053 3/8-16 Stainless Steel Finished Hex Nut 51 EA AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 6 LF MOUNTING MOUNTING PATTERN 1 EA TOUCHUP-PAINT TOUCH-UP PAINT 1 EA DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-021-IL-EX-053H-X EXTRA SPACE STORAGE EXSS-MA001 9/14/2023 Letterset HMD INITIAL CREATION9/14/2023HMDA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-20 WHITE(V2) 3M 3630-22 BLACK(V3) MP 923SP SATIN BLACK MP N202 SATIN WHITE (P4) (P5) SHEET 3 OF 3 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY 3'-6" 1067mm 14'-8 3/4" 4489mm 22'-3 7/16" 6793mm 37'-3 3/16" 11359mm 4'-5 1/4" 1353mm 8 3/16" 208mm 4 11/16" 119mm FRONT VIEW SCALE: 1 : 48 V4 V3 V1 (SHT1) PAINTED TO MATCH RACEWAY - SEE SITEDOC FOR PAINT A 5" 127mm 9 1/4" 235mm SIDE VIEW SCALE: 1 : 48 ISO VIEW SCALE: 1 : 64 Letterset Details NIGHT VIEW - INTERNAL ILLUMINATION "REGISTRATION" MOUNTED TO LETTER RETURN WITH TEK SCREWS A DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-505-IL-RW-053H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-106 GREENV1 3M 3630-22 BLACKV3 V4 3M 3635-222 DUAL COLOR BLACK MP# 923SP SATIN BLACKP4 SHEET 1 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:48 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY 22'-2 15/16" 6781mm 13'-9 5/16" 4199mm 4" 102mm 4" 102mm 3'-0" 914mm 3'-0" 914mm 3'-0" 914mm 3'-0" 914mm 3'-0" 914mm 3'-0" 914mm 4" 102mm 3'-0" 914mm 3'-0" 914mm 3'-0" 914mm 12'-9 1/2" 3899mm SEAM RACE WAY BACK VIEW SCALE: 1:32 DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-505-IL-RW-053H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-106 GREENV1 3M 3630-22 BLACKV3 V4 3M 3635-222 DUAL COLOR BLACK MP# 923SP SATIN BLACKP4 SHEET 2 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:32 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY 5"[127mm] EIFS with Raceway Mounting SECTION DETAIL (WITH RACEWAY) - EIFSSCALE: N.T.S. SEE RACEWAY DETAILS SHEET HDW5 B A HDW1 HDW4 HDW3 ANG1 HDW2 LED1 SHT2 ACR1 TRC1 COL1 A B PAINTED TO MATCH RETURNS (MIN 2) 1/4" WEEP HOLES PER LETTER, LOCATE AT EACH LOW POINT WITH LIGHT SHIELD COVER BRC1 SCALE: N.T.S.BRICK / CONCRETE / TILEMOUNTING OPTION B (WITH RACEWAY)- INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION HDW2 HW-00123 3/8-16 x 12" SS ALL THREAD STUD HDW3 HW-00053 3/8-16 Stainless Steel Finished Hex Nut HDW4 HW-00085 3/8 Stainless Steel Flat Washer HDW5 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE ANG1 AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE MANUFACTURING BILL OF MATERIALS ITEM #PART #DESCRIPTION COL1 AL-CO-040-5_3-270-BLAC 5.3" x .040" x 270' Gloss Black Aluminum Coil TRC1 TR-MG-1-150-4310-DOGR-R 1" 4310 DOVE GREY GEMINI ACR1 A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC SHT2 AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET HDW1 HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL SCREW 410 S/S LED1 USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE ELEC1 EL-EC-00121 HEYCO M4812 SCG 750 SNAP-IN CORDGRIP STRAIN RELIEFS (50/BOX) ELEC2 PG-9841814L-WIRE PAIGE 98P1814L RIP STRIP LED CABLE 18-2 CONDUCTOR MOISTURE RESISTANT 500FT ROLL INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION QTY. BRC1 HW-00275 3/8" x 3" HEAVY DUTY HEX HEAD TAPPING SCREW FOR CONCRETE SCREW TBD DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE EXSS-LTR-505-IL-RW-053H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H SHEET 3 OF 6 VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. C RCW2 RACEWAY SECTION VIEWSCALE: N.T.S. ELC2 B RCW3RHD3 RHD2 A RCW1 ELC3 ELC1 RHD1 EYB1 Raceway Details B 1/4" PLATE DRILLED & TAPPED FOR EYEBOLT (PLATE WELDED TO RACEWAY INTERIOR AS REQ'D) INSTALLER TO REMOVE EYEBOLT AFTER INSTALL & REPLACE W/ (ITEM EYB2)A C RIP OPENING IN ONE SIDE OF TUBE TO FIT ELECTRICAL 4" D D F HDW2 INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION EYB2 HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251 ELC2 EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington NMLT9050) ELC3 EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit MANUFACTURING BILL OF MATERIALS ITEM #PART #DESCRIPTION RCW1 AL-SH-090-60-144 .090 x 60 x 144 ALUMINUM SHEET RCW2 AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE RCW3 AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR EYB1 HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR LIFTING RHD1 HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW RHD2 HW-00053 3/8-16 Stainless Steel Finished Hex Nut RHD3 HW-00085 3/8 Stainless Steel Flat Washer SHT1 AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET ELC1 EL-EC-00052 3/8" ARLINGTON BUSHING HDW1 HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3 HDW2 HW-00048 #8 x 1/2" SS Self-Drilling Screw DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-505-IL-RW-053H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-106 GREENV1 3M 3630-22 BLACKV3 V4 3M 3635-222 DUAL COLOR BLACK MP# 923SP SATIN BLACKP4 SHEET 4 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY Purchasing BOM PURCHASING BOM MANUFACTURING BILL OF MATERIALS PART #DESCRIPTION QTY. HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL SCREW 410 S/S A/R AL-CO-040-5_3-270-BLAC 5.3" x .040" x 270' Gloss Black Aluminum Coil 233'4" TR-MG-1-150-4310-DOGR-R 1" 4310 DOVE GREY GEMINI 233'- 4" A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC 85 SF AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET 120 SF USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE 203 EL-EC-00052 3/8" ARLINGTON BUSHING 2 EL-EC-00121 HEYCO M4812 SCG 750 SNAP-IN CORDGRIP STRAIN RELIEFS (50/BOX)2 PG-9841814L-WIRE PAIGE 98P1814L RIP STRIP LED CABLE 18-2 CONDUCTOR MOISTURE RESISTANT 500FT ROLL 5 LF USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 5 AL-SH-090-60-144 .090 x 60 x 144 ALUMINUM SHEET 10 SF AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE 36 LF AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR 2 SF HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR LIFTING 4 EA HW-00038 3/8-16 x 1-1/2" SS HEX CAP SCREW 95 EA HW-00053 3/8-16 Stainless Steel Finished Hex Nut 95 EA HW-00085 3/8 Stainless Steel Flat Washer 95 EA HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3 8 EA HW-00048 #8 x 1/2" SS Self-Drilling Screw 20 AL-FB-500-2-144 .5 x 2 x 12' ALUMINUM FLAT BAR 2 SF INSTALLATION BILL OF MATERIALS PART #DESCRIPTION QTY. EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington NMLT9050)2 EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit 2 HW-00275 3/8" x 3" HEAVY DUTY HEX HEAD TAPPING SCREW FOR CONCRETE SCREW 26 HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251 4 EA HW-00123 3/8-16 x 12" SS ALL THREAD STUD 26 HW-00053 3/8-16 Stainless Steel Finished Hex Nut 52 HW-00085 3/8 Stainless Steel Flat Washer 52 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 13 LF AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE 24 LF MOUNTING MOUNTING PATTERN 1 EA TOUCHUP-PAINT TOUCH-UP PAINT - (P4)1 EA DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-505-IL-RW-053H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-106 GREENV1 3M 3630-22 BLACKV3 V4 3M 3635-222 DUAL COLOR BLACK MP# 923SP SATIN BLACKP4 SHEET 5 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-505-IL-RW-053H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-106 GREENV1 3M 3630-22 BLACKV3 V4 3M 3635-222 DUAL COLOR BLACK MP# 923SP SATIN BLACKP4 SHEET 6 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:48 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY 11 1/2" 292mm 1'-2" 356mm 3'-9 5/16" 1151mm 1 13/16" 47mm FRONT VIEW SCALE: 1 : 8 V4 SEE SITEDOC FOR PAINT SPEC 3" 76mm 7 1/4" 184mm 4" 102mm 4" 102mm SIDE VIEW SCALE: 1 : 8 ISO VIEW SCALE: 1 : 12 Letterset Details NIGHT VIEW - INTERNAL ILLUMINATION DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-585-IL-RW-014H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4 SHEET 1 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:32 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY 3'-9" 1143mm 4" 102mm 4" 102mm RACEWAY - BACK SCALE: 1 : 12 BRAKE-FORMED .125" MOUNTED TO BACKS OF LETTERS AND A TOP OF RACEWAY W/ (HDW1) TEK SCREW DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-585-IL-RW-014H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4 SHEET 2 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:32 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY SECTION DETAIL (WITH RACEWAY) - EIFSSCALE: N.T.S. SEE RACEWAY DETAILS SHEET HDW5 B A HDW1 HDW4 HDW3 ANG1 HDW2 LED1 SHT1 ACR1 TRC1 COL1 A B PAINTED TO MATCH RETURNS (MIN 2) 1/4" WEEP HOLES PER LETTER, LOCATE AT EACH LOW POINT WITH LIGHT SHIELD COVER 5"[127mm] EIFS with Raceway Mounting SHT2 BRC1 SCALE: N.T.S.BRICK / CONCRETE / TILEMOUNTING OPTION B (WITH RACEWAY)- INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION HDW2 HW-00123 3/8-16 x 12" SS ALL THREAD STUD HDW3 HW-00053 3/8-16 Stainless Steel Finished Hex Nut HDW4 HW-00085 3/8 Stainless Steel Flat Washer HDW5 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE ANG1 AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE MANUFACTURING BILL OF MATERIALS ITEM #PART #DESCRIPTION COL1 AL-CO-040-3_5-270-BLAC- GLO 3.5 x .040 x 270' GLOSS BLACK ALUMINUM COIL TRC1 TR-MJ-1-150-BLAC-R 1" BLACK JEWELITE TRIMCAP ACR1 A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC SHT1 AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET SHT2 AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET HDW1 HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL SCREW 410 S/S LED1 USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE ELEC1 EL-EC-00121 HEYCO M4812 SCG 750 SNAP-IN CORDGRIP STRAIN RELIEFS (50/BOX) ELEC2 PG-9841814L-WIRE PAIGE 98P1814L RIP STRIP LED CABLE 18-2 CONDUCTOR MOISTURE RESISTANT 500FT ROLL INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION QTY. BRC1 HW-00275 3/8" x 3" HEAVY DUTY HEX HEAD TAPPING SCREW FOR CONCRETE SCREW 4 DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE EXSS-LTR-585-IL-RW-014H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H SHEET 3 OF 6 VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 7" 178mm 2" 51mm 4" 102mm 1 1/2" 38mm 1" 25mm 1/2" 13mm MOUNTING PLATE SCALE: 1 : 4 RCW3 Raceway Details B 1/4" PLATE DRILLED & TAPPED FOR EYEBOLT (PLATE WELDED TO RACEWAY INTERIOR AS REQ'D) INSTALLER TO REMOVE EYEBOLT AFTER INSTALL & REPLACE W/ (ITEM EYB2)A C RIP OPENING IN ONE SIDE OF TUBE TO FIT ELECTRICAL 4 1/2" 1/4" WEEP HOLES, LOCATE ALONG BOTTOM.D D C RCW2 RACEWAY SECTION VIEWSCALE: N.T.S. ELC2 B RCW3 A RCW1 ELC3 ELC1 EYB1 HDW1 MANUFACTURING BILL OF MATERIALS ITEM #PART #DESCRIPTION RCW1 AL-SH-090-60-144 .090 x 60 x 144 ALUMINUM SHEET RCW2 AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE RCW3 AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR EYB1 HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR LIFTING RHD1 HW-00044 1/4"-20 x 2" HEX CAP SCREW GRADE 5 ZINC PLATED RHD2 HW-00093 1/4" Split Lock Washer Stainless Steel RHD3 HW-00052 1/4"-20 Stainless Steel Hex Nut SHT1 AL-SH-125-48-96 .125 X 48 X 96 ALUMINUM SHEET (ROUTED GUSSETS) ELC1 EL-EC-00052 3/8" ARLINGTON BUSHING HDW1 HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3 INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION EYB2 HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251 ELC2 EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington NMLT9050) ELC3 EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-585-IL-RW-014H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4 SHEET 4 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY Purchasing BOM PURCHASING BOM INSTALLATION BILL OF MATERIALS PART #DESCRIPTION QTY. EL-EC-00117 1/2" 90 Degree PVC Liquidtite Connector (Arlington NMLT9050)2 EL-EC-00059 1/2" Liquidtite Non-Metallic Conduit 2 HW-00208 SNAP-IN BLACK NYLON PLUG FOR 1/2" ID 9688K251 2 EA HW-00044 1/4"-20 x 2" HEX CAP SCREW GRADE 5 ZINC PLATED 4HW-00093 1/4" Split Lock Washer Stainless Steel 8 HW-00052 1/4"-20 Stainless Steel Hex Nut 4 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 2 LF AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE 12 LF HW-00275 3/8" x 3" HEAVY DUTY HEX HEAD TAPPING SCREW FOR CONCRETE SCREW 4 MOUNTING MOUNTING PATTERN 1 EA TOUCHUP-PAINT TOUCH-UP PAINT - (P4)1 EA MANUFACTURING BILL OF MATERIALS PART #DESCRIPTION QTY. HW-00262 #8 X 1/2 INDENTED HEX HEAD UNSLOTTED SELF-DRILL SCREW 410 S/S A/R AL-CO-040-3_5-270-BLAC- GLO 3.5 x .040 x 270' GLOSS BLACK ALUMINUM COIL 29'2" TR-MJ-1-150-BLAC-R 1" BLACK JEWELITE TRIMCAP 29'-2" A2406-177-51-100 .177 x 51 x 100 2406 WHITE OPTIX LD ACRYLIC 4 SF AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET 30 SF AL-SH-080-48-120-WH .080 x 48 x 120 PRE-PAINTED WHITE ALUMINUM SHEET 4 SF USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE 25 MOD EL-EC-00052 3/8" ARLINGTON BUSHING 2 USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 1 AL-SH-090-48-120 .090 x 48 x 120 ALUMINUM SHEET 2 SF AL-EX-125-4-4-24-TUBE .125" X 4" X 4" X 24' ALUMINUM TUBE 3'-9" AL-FB-240-2-144 .25 x 2 x 12' ALUMINUM FLAT BAR 1 SF HW-00207 1/2"-13 x 1.5" STEEL EYEBOLT W/ SHOULDER FOR LIFTING 2 EA HW-00206 #12 X 1" SS HEX HEAD SELF DRILLING SCREW TEK 3 24 EA AL-FB-500-2-144 .5 x 2 x 12' ALUMINUM FLAT BAR 2 SF DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-585-IL-RW-014H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4 SHEET 5 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-LTR-585-IL-RW-014H EXTRA SPACE STORAGE VARIOUS 8/24/2021 Letterset & Raceway JMB INITIAL CREATION8/24/2021JMBA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3635-222 DUAL COLOR BLACKV4MP# 923SP SATIN BLACK - TOUCH UPP4 SHEET 6 OF 6 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:1 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY 5 Technology Circle ∙ Columbia, SC ∙ 29203 ∙ USA +1.803.926.7926 P ∙ +1.803.926.8412 F www.colite.com SITE DOCUMENT June 14, 2023 EXSS-MA001-R01 # 3120 435 Highland Ave Salem, MA 01970 June 14, 2023 ∙ EXSS-MA001-R01 Page 2 of 9 Corrugated Drywall Brick Wood, Marble, Glass, and Granite Concrete Sidings Stucco and EIFS Wallpaper Exterior Interior To be discussed with client. End result should ensure holes are filled or patched prior to installing new sign. Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex caulk. Prep and paint wall to a Level 4 finish with approved paint color (SHERWIN WILLIAMS or BENJAMIN MOORE). Holes to be filled with QUICKRETE mortar repair sealant or paintable caulk. Pressure wash wall.To be discussed with client prior to budget presentation. Holes to be filled with QUICKRETE concrete repair sealant. Pressure wash wall. Patch holes with pre-approved painted aluminum. Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex caulk. Prep and paint wall with approved paint color (SHERWIN WILLIAMS or BENJAMIN MOORE). * Paint must cure for a minimum of 48 hours prior to graphics installation. Gassing and/or peeling of graphic can occur otherwise. * Electrical is to be brought to signage area prior to sign installation by GC or owner. Wallpaper to be removed and reapplied. PM to consult with client as they may have access to matching wallpaper. WALL REPAIR GUIDELINES June 14, 2023 ∙ EXSS-MA001-R01 Page 3 of 9 A.)Project Name: B.)Street Address: C.)Town / City / State / Zip: D.)Contact for Permit/Zoning: E.)Contact Telephone: Contact E-Mail if available: F.)Jurisdiction: City/Town or, County of: G.)Zoning Classification for property: H.)Is there a Master Sign Plan? I.)Is a permit required? J.) K.)How long is the permit process? L.)What are the fees for a sign permit? M.)Is engineering needed for wall signs? N.)Does engineering require a PE stamp? Are hard copies needed? How many? O.)Is landlord approval required? P.) Legal Description Required for permit? Q.)Plat/Site Plan required for permit? R.)Certificate of Occupancy required for permit? S.)Any special design reviews required (explain)? If yes, projected processing time? 1.) 2.) 3.) 4.) 5.) EXTRA SPACE STORAGE # 3120 $25 plus $11.00 per $1000 (978) 619-5685 City of Salem Salem, MA 01970City, ST Zip: Yes. Yes. bforrestal@salem.com How is the sign area calculated? The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display area of the sign, together with any backing different in color or material from the finish material of the building face, without deduction for open space or other irregularities. Structural members not bearing advertising matters hall not be included unless internally or decoratively lighted. Only one side of flat, back-to-back signs need be included in calculating sign area. B2; Business Highway; Entrance Corridor Overlay (Requires additional reviews; See below) Per Beth: Follow the Design Guidelines and the code. ATTACHED SIGNS (WALL SIGNS & AWNING/CANOPY SIGNS) Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs: Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by  0—99 2 100—399 2.5 400 and over 3 However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent signs. Formula for calculating wall sign square footage (Max. Sq. Footage - Primary & Secondary signs): PRE-PERMIT SIGN INFO Date:5/16/2023 435 Highland Ave Salem MA 01970 What is the max letter/character height allowed? EXTRA SPACE STORAGE # 3120Property ID: Yes. No higher than whichever of the following is lowest: a. Twenty-five feet above sidewalk or finish grade; b. The top of the sills of the first level of windows above the first story; or c. The height of the building at the building line. Yes. Stamped engineering may be required. Based on aggregate area of sign provisions herein; subject to review. Yes. https://www.salem.com/sites/g/files/vyhlif7986/f/uploads/sign_ordinance_worksheet_04- 16.pdf Total # Wall Signs allowed per building elevation: See above. Beth Forrestal Address:98 Washington Street 2nd Floor 3-5 weeks. Normal permitting times are not in effect during the pandemic. As cities learn to revamp the way they do things, you can expect delays. Sq Ft allowance for bldg. sides / rear: What drawings & documents are required to file for the permit? Submit sign permit application using the permit portal. Yes. A sign review committee, comprised of the following members, shall be established for the purpose of reviewing all signage proposed for the ECOD; Building Commissioner or designee; and City Planner or designee; and representative of the Salem Redevelopment Authority. 1. The sign review committee shall review the size, location, type of material and design of all signs located within an ECOD. 2. The sign review committee shall follow the Salem Sign Ordinance, except that the sign review committee shall be allowed to limit the size of all signs within an ECOD to one-half (½) the size which is allowed in the underlying zone. 3. Approval by a simple majority of this committee is required prior to a sign permit being granted by the City. Per Beth: If all is in order, the entire process can take up to 3 weeks to complete. Page 1 of 4 6.) 7.)Are roof mounted signs allowed? 8.)Are raceways allowed? 9.)Other restrictions/comments: 7.)Does window vinyl need to be permitted, if so how much is allowed? 8.)Is the entire graphic calculated or just the company logo and name? 1.) 2.) 3.) 4.) 1.) Does the ordinance restrict color, design or illumination? FREESTANDING SIGNS Formula for calculating freestanding sign sq. footage (Max Sq Footage- Primary & Secondary signs): Wall signs are affixed parallel to the street wall and should be installed in the sign band area above the store entrance. Wall signs should not obscure architectural details or sit in front of windows on upper floors. Painted, raised letters, or a box sign are all possible methods for wall signs. Simplicity and compatibility with the building architecture are important considerations. Wall signs shall not projects no more than 15 inches from the building surface. Architectural lighting is recommended. Light sources should be shielded to prevent glare from shining into neighboring windows or into the eyes of pedestrians and drivers. Only finished and shielded fixtures should be used on building façades. The finish should complement to sign and other façade elements. Internally lighted signs are not recommended in the Entrance Corridors. Internally lighted box signs, particularly with light colored backgrounds are not recommended. Signs shall be lighted only by continuous light, except that a warning sign or a sign illuminated to show time and temperature may have intermittent illumination. Signs shall remain stationary. (a) Flashing lights or simulations of traffic signals or emergency vehicle lights shall not be used on signs. In addition, red and green colored lights shall not be used when so placed that they could obscure or be a hazard to the clear vision of traffic control signals viewed from any point on an approaching public way or if, in the opinion of the building inspector, such light would constitute a hazard. (b) Spotlights or floodlights shall not be aimed so that any portion of the main beam can be seen from a public way. Projection restrictions?It projects no more than five feet from the building; Other restrictions/comments: The bottom of the sign is at least ten feet from grade and its top is no higher than whichever of the following is lowest: 1. Twenty-five feet above sidewalk or finish grade; 2. The top of the sills of the first level of windows above the first story; or 3. The height of the building at the building line; No exposed guy wires or turnbuckles. WINDOW GRAPHICS It is advisable to keep major signs out of windows. A limited amount of lettering in small sizes is appropriate and effective within windows to describe products, address, or hours of operation. These should be carefully organized around the store entrance. A permanent nonilluminated sign on the inside of the glass of a window, provided that the total area of the sign does not exceed 30 percent of the total glass area of windows appurtenant to the use to which the sign is accessory, and provided that signs on ground floor windows be included in calculating the total area of signs on a sign frontage. Permit required. See temporary signs. Entire graphic. PROJECTING SIGNS How many are allowed (maximum)?There is no more than one such sign for each entrance door to a business establishment. The sign advertises a use which occupies at least 18 feet of sign frontage; Maximum sq footage per sign? Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs: Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by  0—99 2 100—399 2.5 400 and over 3 The area of the sign shall not exceed 24 square feet on either side, except that an additional ten square feet on each face is allowed for a sign which incorporates a public service message device such as a time and temperature sign. No. Per Beth: individual halo lit channel letters are okay in the ECOD as well as external lighting. N/A Page 2 of 4 CODE RESEARCH June 14, 2023 ∙ EXSS-MA001-R01 Page 4 of 9 2.)# F/S Signs allowed: 3.)Height Maximum: 4.)Set-back of sign from right-of-way or property line: 5.)Engineering required? 6.)Permit required for reface? 7.)Other restrictions/comments: 5.)Number Allowed: 6.)Illumination Allowed? 7.)Permit Required?: 1.) 2.) 3.) 4.) 5.) 6.) 7.) Property I.D. # 1.) 2.) 3.) 4.) 5.) 6.) Yes. Customer Logo Allowed:Shall bear no advertising. No permit is required or temporary window signs. Yes. PRE-PERMIT SIGN INFO - Notes, continued EXTRA SPACE STORAGE # 3120 Variance document deadline? A lot with a front lot line of 200 or more feet may have two freestanding signs.Internal illumination allowed: Internally lighted signs are not recommended in the Entrance Corridors. Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs: Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by  0—99 2 100—399 2.5 400 and over 3 However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent signs. If there are one or two uses on the lot, the area of each face does not exceed 65 square feet. Variance cost? Clearance from grade to sign: See illumination restrictions. Variance meeting dates? https://www.salemma.gov/zoning-board-appeals/files/zoning-board-appeals-application-guide How many sets?2 copies. Variance documents required? How is the sign area calculated? Are logos factored into sign area? $250 and up. Variance time frame?2-4 months. Applications will be accepted each month on a first come, first served basis. Once the monthly meeting agenda is full, petitions will be carried over to the following month’s meeting. Petitioners are encouraged to submit their applications as early as possible. See below. DIRECTIONAL SIGNS Directional signs necessary for public safety.Maximum Square Footage:12 square feet per face . Cannot project into right of way; Cannot obstruct view. Subject to Site plan review. The top of such sign is no higher than 25 feet above sidewalk or finish grade. How long can signs be up? Does the ordinance restrict color, design or illumination? VARIANCE INFORMATION Signs shall not obstruct view. Subject to review. https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/boa_23_24_schedule_approved.pdf How many signs per elevation? Maximum Height:Not stipulated in the code. Subject to review. What temporary sign types are allowed? TEMPORARY BANNERS Contractor sign: One sign. Contractor sign: not exceeding 32 square feet in total area. Temporary signs: affixed to windows, provided that their total area does not exceed 30 percent of the window. The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display area of the sign, together with any backing different in color or material from the finish material of the building face, without deduction for open space or other irregularities. Structural members not bearing advertising matters hall not be included unless internally or decoratively lighted. Only one side of flat, back-to-back signs need be included in calculating sign area. Contractor sign: Temporary signs pertaining to special sales or events Contractor sign: On a lot where a building is actually under construction. Temporary sign: No more than 15 days. What is the max sign size area? No permit shall be effective until the director of public services and the city electrician, for illuminated signs, shall have filed with the city clerk a certification that such sign is securely fastened so as not to endanger persons upon the sidewalk or street. A sign for which a permit is required may be inspected periodically by the building inspector for compliance with this article and other requirements of law. Except for copy changes on signs with changeable letter panels, no on-premises sign shall be reconstructed, extended, changed structurally or in content or replaced except in accordance with this article. Signs shall not obstruct view. Subject to review. Page 3 of 4 7.)Likelihood of variance approval? This code check is provided with the assumption that you will get the landlord / property owner approval. The information herein is limited to what the city has told us, and we cannot be responsible if they do not inform us that a sign plan is in place. We strongly encourage you to check your lease for landlord criteria and to apply for permits before manufacturing a sign. Sign criteria is reported as presented to us as of the "Completion Date". ETD is not responsible for changes in local sign code after the completion date, nor for the review process interpretations, calculations or fees of local authorities. It is understood that a permit will be obtained prior to manufacture, if required by authorities. The recipient of this code check understands and agrees to the following: This code check is not exclusive and should not be used in place of the definitions, prohibitions and exemptions of the ordinance. This code check is good for the day on which it is completed only. Information contained herein is a guideline and should not in any way be taken as a permit approval. Signs should not be produced until the permit has been issued. Zoning approval is often subject to interpretation that said official makes of the ordinance for their city/county/township; we cannot be held responsible for verbal answers and interpretation. This code check is completed without the knowledge of specific project details and Expedite The Diehl LLC does not assume any liability, we simply provide the code information based on the current code. 2023 MISC. NOTES 20% https://library.municode.com/ma/salem/codes/code_of_ordinances?nodeId=PTIIICOOR_CH4AD_ARTIISIBI https://library.municode.com/ma/salem/codes/zoning_ordinance?nodeId=S8.0SPDIRE_8.2ENCOOVDIEC Design Guidelines https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/sdg_all_pages_0.pdf Overlay Page 4 of 4 CODE RESEARCH June 14, 2023 ∙ EXSS-MA001-R01 Page 5 of 9 SIGN INVENTORY L#EXISTING RECOMMENDATION QTY 1 Pylon Panel 2 2 Letterset Letterset 1 3 Letterset Panel 1 4 None Letterset 1 SITE MAP Surveyor:- 1 3 4 June 14, 2023 ∙ EXSS-MA001-R01 Page 6 of 9 Quantity Sign Sq.Ft.Illumination Face Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: EXISTING SIGN DETAILS: Quantity Depth Sign Sq. Ft.Illumination Face Mounting Fabrication CONTEXT PHOTOS: SURVEY NOTES: Pylon Sign Cut Size for Face: 107.5”W x 93”H EXSS-FPL-004-IL-SF-093H-X Remove existing panel faces. Install new panels in existing cabinet. Paint existing cabinet and pole Extra Space Storage Gray. Cabinet retainer to be repaired. RETROFIT WITH USLED. Existing survey measurements to be confirmed. Technical survey required prior to production. Existing: Recommendation: Pylon Panel LOCATION1 FRONT VIEW SCALE: NTS SIDE VIEW SCALE: NTS 0.188” [5mm] 7’-9” [2362mm] 8’-11.5” [2731mm] 3’-1.11” [943mm] 7’-9” [2362mm] 8’-11.5” [2731mm] NIGHT VIEW LOCATION 1 2 69.4 Face Lit Single - Existing Frame Flat Polycarbonate Panel 1 Unknown 69.4 Face Lit Double Unknown Fabricated Pylon IMAGING/SCALING IS ESTIMATED NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES June 14, 2023 ∙ EXSS-MA001-R01 Page 7 of 9 Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: EXISTING SIGN DETAILS: Quantity Depth Sign Sq. Ft.Illumination Mounting Fabrication NO PHOTO AVAILABLE CONTEXT PHOTOS: SURVEY NOTES: Letter “L” is 48” tall. EXSS-LTR-505-IL-RW-053H Remove existing letterset. Install new letterset in its place. Existing wall color needs to be determined prior to production. Complete restoration and paint in repair area shown (See wall repair guidelines). Existing: Recommendation: Letterset Letterset LOCATION2 FRONT VIEW SCALE: NTS 22’-3.45” [6793mm] 14’-8.74” [4489mm] 37’-9.79” [11526mm] SIDE VIEW SCALE: NTS 5” [127mm] 4’-5.26” [1353mm] 3’-6” [1067mm]2’-6.74” [7891mm] 39’-0” [11887mm] 7’-0” [2134mm] LOCATION 2 1 167.84 Face Lit 254 Raceway ESS-ILL42GB-RW 1 Unknown 273 Face Lit Raceway Channel Letterset on Raceway NIGHT VIEW NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES Repair Area 254 SQ.FT. June 14, 2023 ∙ EXSS-MA001-R01 Page 8 of 9 Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: EXISTING SIGN DETAILS: Quantity Depth Sign Sq. Ft.Illumination Mounting Fabrication NO PHOTO AVAILABLE CONTEXT PHOTOS: SURVEY NOTES: EXSS-WPL-501-IL-SF-061H Remove existing letterset. Install new letterset in its place. Existing wall color needs to be determined prior to production. Complete restoration and paint in repair area shown (See wall repair guidelines). Existing: Recommendation: Letterset Panel LOCATION3 FRONT VIEW SCALE: NTS SIDE VIEW SCALE: NTS 1’-6” [457mm] 5’-1.04” [1550mm] 11’-3” [3429mm] 3’-8.8” [1138mm] 9’-5.09” [2872mm] 7’-0” [2134mm] 7’-0” [2134mm] NIGHT VIEW LOCATION 3 1 57.2 Face Lit 96 Brackets ESS-W57 1 Unknown 49 Face Lit Raceway Channel Letterset on Raceway NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES Repair Area 96 SQ.FT. June 14, 2023 ∙ EXSS-MA001-R01 Page 9 of 9 Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: NO PHOTO AVAILABLE CONTEXT PHOTOS: SURVEY NOTES: No survey dimensions provided for canopy. EXSS-LTR-585-IL-RW-014H Install new letterset on top of canopy. Raceway color: SW7069 Iron Ore Existing canopy dimensions and color needs to be determined prior to production. Existing: Recommendation: None Letterset LOCATION4 FRONT VIEW SCALE: NTS SIDE VIEW SCALE: NTS 3” [76mm] 3’-9.5” [1156mm] 1’-2” [356mm] 11.5” [292mm] Raceway painted to match SW7069 Iron Ore LOCATION 4 1 4.42 Face Lit - Raceway Channel Letterset NEED MORE INFORMATION PRIOR TO PRODUCTION: SEE NOTES NIGHT VIEW IMAGING/SCALING IS ESTIMATED 5 Technology Circle ∙ Columbia, SC ∙ 29203 ∙ USA +1.803.926.7926 P ∙ +1.803.926.8412 F www.colite.com SITE DOCUMENT August 22, 2023 EXSS-MA001-R04 # 3120 435 Highland Ave Salem, MA 01970 August 22, 2023 ∙ EXSS-MA001-R04 Page 2 of 10 Corrugated Drywall Brick Wood, Marble, Glass, and Granite Concrete Sidings Stucco and EIFS Wallpaper Exterior Interior To be discussed with client. End result should ensure holes are filled or patched prior to installing new sign. Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex caulk. Prep and paint wall to a Level 4 finish with approved paint color (SHERWIN WILLIAMS or BENJAMIN MOORE). Holes to be filled with QUICKRETE mortar repair sealant or paintable caulk. Pressure wash wall.To be discussed with client prior to budget presentation. Holes to be filled with QUICKRETE concrete repair sealant. Pressure wash wall. Patch holes with pre-approved painted aluminum. Patch holes or re-mediate wall with DAP ALEX PLUS all-purpose acrylic latex caulk. Prep and paint wall with approved paint color (SHERWIN WILLIAMS or BENJAMIN MOORE). * Paint must cure for a minimum of 48 hours prior to graphics installation. Gassing and/or peeling of graphic can occur otherwise. * Electrical is to be brought to signage area prior to sign installation by GC or owner. Wallpaper to be removed and reapplied. PM to consult with client as they may have access to matching wallpaper. WALL REPAIR GUIDELINES August 22, 2023 ∙ EXSS-MA001-R04 Page 3 of 10 A.)Project Name: B.)Street Address: C.)Town / City / State / Zip: D.)Contact for Permit/Zoning: E.)Contact Telephone: Contact E-Mail if available: F.)Jurisdiction: City/Town or, County of: G.)Zoning Classification for property: H.)Is there a Master Sign Plan? I.)Is a permit required? J.) K.)How long is the permit process? L.)What are the fees for a sign permit? M.)Is engineering needed for wall signs? N.)Does engineering require a PE stamp? Are hard copies needed? How many? O.)Is landlord approval required? P.) Legal Description Required for permit? Q.)Plat/Site Plan required for permit? R.)Certificate of Occupancy required for permit? S.)Any special design reviews required (explain)? If yes, projected processing time? 1.) 2.) 3.) 4.) 5.) EXTRA SPACE STORAGE # 3120 $25 plus $11.00 per $1000 (978) 619-5685 City of Salem Salem, MA 01970City, ST Zip: Yes. Yes. bforrestal@salem.com How is the sign area calculated? The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display area of the sign, together with any backing different in color or material from the finish material of the building face, without deduction for open space or other irregularities. Structural members not bearing advertising matters hall not be included unless internally or decoratively lighted. Only one side of flat, back-to-back signs need be included in calculating sign area. B2; Business Highway; Entrance Corridor Overlay (Requires additional reviews; See below) Per Beth: Follow the Design Guidelines and the code. ATTACHED SIGNS (WALL SIGNS & AWNING/CANOPY SIGNS) Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs: Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by  0—99 2 100—399 2.5 400 and over 3 However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent signs. Formula for calculating wall sign square footage (Max. Sq. Footage - Primary & Secondary signs): PRE-PERMIT SIGN INFO Date:5/16/2023 435 Highland Ave Salem MA 01970 What is the max letter/character height allowed? EXTRA SPACE STORAGE # 3120Property ID: Yes. No higher than whichever of the following is lowest: a. Twenty-five feet above sidewalk or finish grade; b. The top of the sills of the first level of windows above the first story; or c. The height of the building at the building line. Yes. Stamped engineering may be required. Based on aggregate area of sign provisions herein; subject to review. Yes. https://www.salem.com/sites/g/files/vyhlif7986/f/uploads/sign_ordinance_worksheet_04- 16.pdf Total # Wall Signs allowed per building elevation: See above. Beth Forrestal Address:98 Washington Street 2nd Floor 3-5 weeks. Normal permitting times are not in effect during the pandemic. As cities learn to revamp the way they do things, you can expect delays. Sq Ft allowance for bldg. sides / rear: What drawings & documents are required to file for the permit? Submit sign permit application using the permit portal. Yes. A sign review committee, comprised of the following members, shall be established for the purpose of reviewing all signage proposed for the ECOD; Building Commissioner or designee; and City Planner or designee; and representative of the Salem Redevelopment Authority. 1. The sign review committee shall review the size, location, type of material and design of all signs located within an ECOD. 2. The sign review committee shall follow the Salem Sign Ordinance, except that the sign review committee shall be allowed to limit the size of all signs within an ECOD to one-half (½) the size which is allowed in the underlying zone. 3. Approval by a simple majority of this committee is required prior to a sign permit being granted by the City. Per Beth: If all is in order, the entire process can take up to 3 weeks to complete. Page 1 of 4 6.) 7.)Are roof mounted signs allowed? 8.)Are raceways allowed? 9.)Other restrictions/comments: 7.)Does window vinyl need to be permitted, if so how much is allowed? 8.)Is the entire graphic calculated or just the company logo and name? 1.) 2.) 3.) 4.) 1.) Does the ordinance restrict color, design or illumination? FREESTANDING SIGNS Formula for calculating freestanding sign sq. footage (Max Sq Footage- Primary & Secondary signs): Wall signs are affixed parallel to the street wall and should be installed in the sign band area above the store entrance. Wall signs should not obscure architectural details or sit in front of windows on upper floors. Painted, raised letters, or a box sign are all possible methods for wall signs. Simplicity and compatibility with the building architecture are important considerations. Wall signs shall not projects no more than 15 inches from the building surface. Architectural lighting is recommended. Light sources should be shielded to prevent glare from shining into neighboring windows or into the eyes of pedestrians and drivers. Only finished and shielded fixtures should be used on building façades. The finish should complement to sign and other façade elements. Internally lighted signs are not recommended in the Entrance Corridors. Internally lighted box signs, particularly with light colored backgrounds are not recommended. Signs shall be lighted only by continuous light, except that a warning sign or a sign illuminated to show time and temperature may have intermittent illumination. Signs shall remain stationary. (a) Flashing lights or simulations of traffic signals or emergency vehicle lights shall not be used on signs. In addition, red and green colored lights shall not be used when so placed that they could obscure or be a hazard to the clear vision of traffic control signals viewed from any point on an approaching public way or if, in the opinion of the building inspector, such light would constitute a hazard. (b) Spotlights or floodlights shall not be aimed so that any portion of the main beam can be seen from a public way. Projection restrictions?It projects no more than five feet from the building; Other restrictions/comments: The bottom of the sign is at least ten feet from grade and its top is no higher than whichever of the following is lowest: 1. Twenty-five feet above sidewalk or finish grade; 2. The top of the sills of the first level of windows above the first story; or 3. The height of the building at the building line; No exposed guy wires or turnbuckles. WINDOW GRAPHICS It is advisable to keep major signs out of windows. A limited amount of lettering in small sizes is appropriate and effective within windows to describe products, address, or hours of operation. These should be carefully organized around the store entrance. A permanent nonilluminated sign on the inside of the glass of a window, provided that the total area of the sign does not exceed 30 percent of the total glass area of windows appurtenant to the use to which the sign is accessory, and provided that signs on ground floor windows be included in calculating the total area of signs on a sign frontage. Permit required. See temporary signs. Entire graphic. PROJECTING SIGNS How many are allowed (maximum)?There is no more than one such sign for each entrance door to a business establishment. The sign advertises a use which occupies at least 18 feet of sign frontage; Maximum sq footage per sign? Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs: Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by  0—99 2 100—399 2.5 400 and over 3 The area of the sign shall not exceed 24 square feet on either side, except that an additional ten square feet on each face is allowed for a sign which incorporates a public service message device such as a time and temperature sign. No. Per Beth: individual halo lit channel letters are okay in the ECOD as well as external lighting. N/A Page 2 of 4 CODE RESEARCH August 22, 2023 ∙ EXSS-MA001-R04 Page 4 of 10 2.)# F/S Signs allowed: 3.)Height Maximum: 4.)Set-back of sign from right-of-way or property line: 5.)Engineering required? 6.)Permit required for reface? 7.)Other restrictions/comments: 5.)Number Allowed: 6.)Illumination Allowed? 7.)Permit Required?: 1.) 2.) 3.) 4.) 5.) 6.) 7.) Property I.D. # 1.) 2.) 3.) 4.) 5.) 6.) Yes. Customer Logo Allowed:Shall bear no advertising. No permit is required or temporary window signs. Yes. PRE-PERMIT SIGN INFO - Notes, continued EXTRA SPACE STORAGE # 3120 Variance document deadline? A lot with a front lot line of 200 or more feet may have two freestanding signs.Internal illumination allowed: Internally lighted signs are not recommended in the Entrance Corridors. Total sign area for all signs permanent signs on a sign frontage, except for signs on windows above the first floor, freestanding signs, and directional signs: Average Distance of Sign From Centerline of Abutting Street Sign Frontage* Multiplied by  0—99 2 100—399 2.5 400 and over 3 However, a use with less than 25 feet of sign frontage may have a maximum of 50 square feet of permanent signs. If there are one or two uses on the lot, the area of each face does not exceed 65 square feet. Variance cost? Clearance from grade to sign: See illumination restrictions. Variance meeting dates? https://www.salemma.gov/zoning-board-appeals/files/zoning-board-appeals-application-guide How many sets?2 copies. Variance documents required? How is the sign area calculated? Are logos factored into sign area? $250 and up. Variance time frame?2-4 months. Applications will be accepted each month on a first come, first served basis. Once the monthly meeting agenda is full, petitions will be carried over to the following month’s meeting. Petitioners are encouraged to submit their applications as early as possible. See below. DIRECTIONAL SIGNS Directional signs necessary for public safety.Maximum Square Footage:12 square feet per face . Cannot project into right of way; Cannot obstruct view. Subject to Site plan review. The top of such sign is no higher than 25 feet above sidewalk or finish grade. How long can signs be up? Does the ordinance restrict color, design or illumination? VARIANCE INFORMATION Signs shall not obstruct view. Subject to review. https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/boa_23_24_schedule_approved.pdf How many signs per elevation? Maximum Height:Not stipulated in the code. Subject to review. What temporary sign types are allowed? TEMPORARY BANNERS Contractor sign: One sign. Contractor sign: not exceeding 32 square feet in total area. Temporary signs: affixed to windows, provided that their total area does not exceed 30 percent of the window. The area of the smallest horizontally or vertically oriented rectangle which could enclose all the display area of the sign, together with any backing different in color or material from the finish material of the building face, without deduction for open space or other irregularities. Structural members not bearing advertising matters hall not be included unless internally or decoratively lighted. Only one side of flat, back-to-back signs need be included in calculating sign area. Contractor sign: Temporary signs pertaining to special sales or events Contractor sign: On a lot where a building is actually under construction. Temporary sign: No more than 15 days. What is the max sign size area? No permit shall be effective until the director of public services and the city electrician, for illuminated signs, shall have filed with the city clerk a certification that such sign is securely fastened so as not to endanger persons upon the sidewalk or street. A sign for which a permit is required may be inspected periodically by the building inspector for compliance with this article and other requirements of law. Except for copy changes on signs with changeable letter panels, no on-premises sign shall be reconstructed, extended, changed structurally or in content or replaced except in accordance with this article. Signs shall not obstruct view. Subject to review. Page 3 of 4 7.)Likelihood of variance approval? This code check is provided with the assumption that you will get the landlord / property owner approval. The information herein is limited to what the city has told us, and we cannot be responsible if they do not inform us that a sign plan is in place. We strongly encourage you to check your lease for landlord criteria and to apply for permits before manufacturing a sign. Sign criteria is reported as presented to us as of the "Completion Date". ETD is not responsible for changes in local sign code after the completion date, nor for the review process interpretations, calculations or fees of local authorities. It is understood that a permit will be obtained prior to manufacture, if required by authorities. The recipient of this code check understands and agrees to the following: This code check is not exclusive and should not be used in place of the definitions, prohibitions and exemptions of the ordinance. This code check is good for the day on which it is completed only. Information contained herein is a guideline and should not in any way be taken as a permit approval. Signs should not be produced until the permit has been issued. Zoning approval is often subject to interpretation that said official makes of the ordinance for their city/county/township; we cannot be held responsible for verbal answers and interpretation. This code check is completed without the knowledge of specific project details and Expedite The Diehl LLC does not assume any liability, we simply provide the code information based on the current code. 2023 MISC. NOTES 20% https://library.municode.com/ma/salem/codes/code_of_ordinances?nodeId=PTIIICOOR_CH4AD_ARTIISIBI https://library.municode.com/ma/salem/codes/zoning_ordinance?nodeId=S8.0SPDIRE_8.2ENCOOVDIEC Design Guidelines https://www.salemma.gov/sites/g/files/vyhlif7986/f/uploads/sdg_all_pages_0.pdf Overlay Page 4 of 4 CODE RESEARCH August 22, 2023 ∙ EXSS-MA001-R04 Page 5 of 10 SIGN INVENTORY L#EXISTING RECOMMENDATION QTY 1 Pylon Panel 2 2 Letterset Letterset 1 3 Letterset Panel 1 4 None Letterset 1 SITE MAP Surveyor:- 1 3 4 August 22, 2023 ∙ EXSS-MA001-R04 Page 6 of 10 Quantity Sign Sq.Ft.Illumination Face Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: EXISTING SIGN DETAILS: Quantity Depth Sign Sq. Ft.Illumination Face Mounting Fabrication CONTEXT PHOTOS: SURVEY NOTES: Pylon Sign Visual Opening for Face: 8’-8.38” W x 5’-9.5” H. Cut size for face is 8’-11.5” W x 6’-1” H. Important: sign cabinet is rusting and is not secure. EXSS-RFC-004-IL-DF-073H-X Remove existing panel faces. Install new panels in existing cabinet. Paint existing cabinet and pole Extra Space Storage Gray. Cabinet retainer to be repaired. RETROFIT WITH USLED. Existing: Recommendation: Pylon Panel LOCATION1 FACE 1 SCALE: NTS SIDE VIEW SCALE: NTS FACE 2 SCALE: NTS 6’-1” [1854mm] 8’-11.5” [2731mm] 5’-9.5” [1765mm] Visual Opening 8’-8.38” [2651mm] Visual Opening 0.188” [5mm] NIGHT VIEW LOCATION 1 1 54.5 Face Lit Double - Existing Frame Flat Polycarbonate Panel 1 Unknown 54.5 Face Lit Double Unknown Fabricated Pylon August 22, 2023 ∙ EXSS-MA001-R04 Page 7 of 10 Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: EXISTING SIGN DETAILS: Quantity Depth Sign Sq. Ft.Illumination Mounting Fabrication NO PHOTO AVAILABLE CONTEXT PHOTOS: SURVEY NOTES: Letter “L” is 48” tall. Wall color is RVW White. EXSS-LTR-020-IL-EX-053H-X EXSS-WPL-006-NL-SF-072H-X Remove existing letterset. Install new letterset in its place. Complete restoration and paint in repair area shown (See wall repair guidelines). Custom per client request. Existing: Recommendation: Letterset Letterset LOCATION2 FRONT VIEW SCALE: NTS SIDE VIEW SCALE: NTS 22’-3.45” [6793mm] 14’-8.74” [4489mm] 4’-5.26” [1353mm] 2’-6.74” [7891mm] 37’-9.79” [11526mm] 5” [127mm] 3’-6” [1067mm] Seam 39’-0” [11887mm] 2” [51mm] 6’-0” [1829mm] wall panel to match existing wall color, RVW White 39’-0” [11887mm] 7’-0” [2134mm] LOCATION 2 Option A 1 167.84 Halo Lit 254 Studs/Brackets Halo Lit Letterset with Backer Panel 1 Unknown 273 Face Lit Raceway Channel Letterset on Raceway NIGHT VIEW Paint Area 254 SQ.FT. August 22, 2023 ∙ EXSS-MA001-R04 Page 8 of 10 Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: EXISTING SIGN DETAILS: Quantity Depth Sign Sq. Ft.Illumination Mounting Fabrication NO PHOTO AVAILABLE CONTEXT PHOTOS: SURVEY NOTES: Letter “L” is 48” tall. Wall color is RVW White. EXSS-LTR-021-IL-EX-053H-X EXSS-WPL-007-NL-SF-072H-X Remove existing letterset. Install new letterset in its place. Complete restoration and paint in repair area shown (See wall repair guidelines). Custom per client request. Existing: Recommendation: Letterset Letterset FRONT VIEW SCALE: NTS SIDE VIEW SCALE: NTSwall panel to match: MP46295 to Match SW6923 Festival Green 22’-3.45” [6793mm] 14’-8.74” [4489mm] 4’-5.26” [1353mm] 2’-6.74” [7891mm] 37’-9.79” [11526mm] Seam 39’-0” [11887mm] 5” [127mm]2” [51mm] 6’-0” [1829mm] 3’-6” [1067mm] 39’-0” [11887mm] 7’-0” [2134mm] LOCATION 2 Option B 1 167.84 Halo Lit 254 Studs/Brackets Halo Lit Letterset with Backer Panel 1 Unknown 273 Face Lit Raceway Channel Letterset on Raceway NIGHT VIEW Paint Area 254 SQ.FT. August 22, 2023 ∙ EXSS-MA001-R04 Page 9 of 10 Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: EXISTING SIGN DETAILS: Quantity Depth Sign Sq. Ft.Illumination Mounting Fabrication NO PHOTO AVAILABLE CONTEXT PHOTOS: SURVEY NOTES: Existing electrical behind sheet metal. Wall color is RVW White EXSS-WPL-004-IL-SF-061H-X Remove existing letterset. Install new letterset in its place. Complete restoration and paint in repair area shown (See wall repair guidelines). Custom per client request. Existing: Recommendation: Letterset Panel LOCATION3 FRONT VIEW SCALE: NTS SIDE VIEW SCALE: NTS 5’-1.04” [1550mm] 11’-3” [3429mm] 3’-8.8” [1138mm] 9’-5.09” [2872mm] 1’-0” [306mm] 3” [76mm] 7’-0” [2134mm] 7’-0” [2134mm] NIGHT VIEW LOCATION 3 1 57.2 Halo Lit 96 Brackets Fabricated Wall Panel with Halo Lit Letterset 1 Unknown 49 Face Lit Raceway Channel Letterset on Raceway Paint Area 96 SQ.FT. August 22, 2023 ∙ EXSS-MA001-R04 Page 10 of 10 Quantity Sign Sq.Ft.Illumination Estimated Paint Sq.Ft. Mounting Fabrication RECOMMENDATION DETAILS: INSTALLATION/REPAIR NOTES: PART #: SIGN DETAIL: NO PHOTO AVAILABLE CONTEXT PHOTOS: SURVEY NOTES: Color of canopy is Pantone 286 CP. Canopy is 3’-0” deep. Doors are 2’-3” W x 6’-6.25” H. EXSS-LTR-018-NL-RW-014H-X Install new letterset on top of canopy. Existing: Recommendation: None Letterset LOCATION5 FRONT VIEW SCALE: NTS SIDE VIEW SCALE: NTS 3’-9.5” [1156mm] 1’-2” [356mm] 11.5” [292mm] 0.5” [13mm] Raceway painted Cool Grey 11 28’-1.63” [8576mm] 6” [152mm] LOCATION 4 1 4.42 None - Raceway Flat Cut Out Letterset 11'-3" 3428.94mm 5'-1 1/16" 1550.42mm 1 11/16" 42.31mm 1'-1 3/8" 340.22mm 8'-11 15/16" 2741.07mm 3'-8 11/16" 1135.78mm 3'-0 1/4" 921.01mm FRONT VIEW SCALE: 1 : 16 V1 V3 7" 178.05mm SIDE VIEW SCALE: 1 : 16 P2 DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-WPL-501-IL-SF-061H OVERALL EXTRA SPACE STORAGE VARIOUS 6/22/2023 WALL PANEL TEL INITIAL CREATION2/22/2023TELA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS. 3M 3630-106 Green(V1) 3M 3630-22 Black(V3) MP38501 to match SW7067 Cityscape(P2) SHEET 1 OF 4 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:24 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY 11'-3" 3428.94mm 1'-4" 406.40mm 2'-8" 812.80mm VIEW SCALE: 1 : 22 ANG1 SHT2 ELC3 PWR1 ANG1 SHT1 FLX1 SHT2 HDW1 EXTR1 HDW2 HDW3 HDW4 EXTR2 EXTR3 ELC1 ELC2 ANG1 SCH1 SHT3 SHT4 INSTALLATION BILL OF MATERIALS ITEM #PART #DESCRIPTION HDW2 HW-00123 3/8-16 x 12" SS ALL THREAD STUD HDW3 HW-00085 3/8 Stainless Steel Flat Washer HDW4 HW-00053 3/8-16 Stainless Steel Finished Hex Nut ANG2 AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE SCH1 AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE MANUFACTURING BILL OF MATERIALS ITEM #PART #DESCRIPTION FLX1 3M-PANAGRAPHICS 3M PANAGRAPHICSIII FLEXIBLE SUBSTRATE 126" X 164' (FLEXFACE) SHT1 AL-SH-125-72-144 .125 x 72 x 144 ALUMINUM SHEET SHT2 AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET ( BREAKFORM 2" X 3.5" CHANNEL) SHT3 AL-SH-090-48-120 .090 x 48 x 120 ALUMINUM SHEET (METAL TRIMCAP) SHT4 AL-SH-063-60-120 .063 x 60 x 120 ALUMINUM SHEET (METAL TRIMCAP) ANG1 AL-EX-125-2-2-24-ANGL-S .125 X 2 X 2 X 24' ALUMINUM STRUCTURAL ANGLE EXTR1 CU-EX-00004 SIGNCOMP 2121 Flat Bleed Retro Frame Cover EXTR2 EL-EC-00070 SIGNCOMP #5360 BLACK PLASTIC TENSION CLIPS EXTR3 CU-EX-SIGNCO-2107 SIGNCOMP 2107 FLAT BLEED RETRO FRAME II LED1 USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE PWR1 USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60WELC1HW-00063 1/2" Conduit Lock NutELC2EL-EC-00077 WALLBUSTER 14"L x 1/2" DIA. PAIGE ELECTRIC ELC3 EL-EC-00071 Transco Toggle Disconnect Switch 20AMP HDW1 HW-00035 Hinge Screw 5178 ELC3 EL-EC-00071 Transco Toggle Disconnect Switch 20AMP DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-WPL-501-IL-SF-061H SECTION DETAIL EXTRA SPACE STORAGE VARIOUS 6/22/2023 WALL PANEL TEL INITIAL CREATION6/22/2023TELA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.SHEET 2 OF 4 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:16 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY MANUFACTURING BILL OF MATERIALS PART #DESCRIPTION QTY. 3M-PANAGRAPHICS 3M PANAGRAPHICSIII FLEXIBLE SUBSTRATE 126" X 164' (FLEXFACE)12 LF AL-SH-125-72-144 .125 x 72 x 144 ALUMINUM SHEET 53 SF AL-SH-125-48-96 .125 x 48 x 96 ALUMINUM SHEET ( BREAKFORM 2" X 3.5" CHANNEL)25 SF AL-SH-090-48-120 .090 x 48 x 120 ALUMINUM SHEET (METAL TRIMCAP)25 SF AL-SH-063-60-120 .063 x 60 x 120 ALUMINUM SHEET (METAL TRIMCAP)25 SF AL-EX-125-2-2-24-ANGL-S .125 X 2 X 2 X 24' ALUMINUM STRUCTURAL ANGLE 16 LF CU-EX-00004 SIGNCOMP 2121 Flat Bleed Retro Frame Cover 28 LF EL-EC-00070 SIGNCOMP #5360 BLACK PLASTIC TENSION CLIPS A/R CU-EX-SIGNCO-2107 SIGNCOMP 2107 FLAT BLEED RETRO FRAME II 28 LF USLED-PXL2-2-12-W PXL2-2-12-2 US LED 1.5 MODULES/FT 1260/CASE 199 EA USLED-PSB-1-12-60 PSB-1-12-60 US LED POWER SUPPLY 12V/60W 5 EAHW-00063 1/2" Conduit Lock Nut 1 EAEL-EC-00077 WALLBUSTER 14"L x 1/2" DIA. PAIGE ELECTRIC 1 EA EL-EC-00071 Transco Toggle Disconnect Switch 20AMP 1 EA HW-00035 Hinge Screw 5178 A/R INSTALLATION BILL OF MATERIALS PART #DESCRIPTION QTY. HW-00123 3/8-16 x 12" SS ALL THREAD STUD 8 EA HW-00085 3/8 Stainless Steel Flat Washer 16 EA HW-00053 3/8-16 Stainless Steel Finished Hex Nut 16 EA AL-EX-187-2-2-24-ANGL-S .1875 X 2 X 2 X 24' STRUCTURAL ALUMINUM ANGLE 22 LF AL-EX-375-SCH40-20-PIPE .375 X 20' SCH 40 ALUMINUM PIPE 10 LF TOUCHUP-PAINT TOUCH UP PAINT (P2)1 EA DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-WPL-501-IL-SF-061H B.O.M EXTRA SPACE STORAGE VARIOUS 6/22/2023 WALL PANEL TEL INITIAL CREATION6/2/2023TELA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.SHEET 3 OF 4 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:16 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY DESCRIPTIONDATEBYREV REVISIONS 11X17 PRINTDRAWN BY DATE LOCATION CUSTOMER TITLE SIGN TYPE DRAWING NUMBER THIS IS AN ORIGINAL UNPUBLISHED DESIGN CREATED BY COLITE. IT IS SUBMITTED FOR YOUR PERSONAL USE IN CONNECTION WITH THE PROJECT PLANNED FOR YOU BY COLITE. IT IS NOT TO BE SHOWN TO ANYONE OUTSIDE YOUR ORGANIZATION NOR IS IT TO BE USED, REPRODUCED, COPIED, OR EXHIBITED IN ANY FASHION WHATSOEVER. ALL OR ANY PART OF THIS DESIGN (EXCEPTING REGISTERED TRADEMARKS) REMAIN THE PROPERTY OF COLITE. P 803 926.7926 COLUMBIA SC 292035 TECHNOLOGY CIRCLE SPECIFICATIONS - PAINT, VINYL, DIGITAL PRINT EXSS-WPL-501-IL-SF-061H Sheet4 VARIOUS INITIAL CREATIONA C B E D F G J I H NOTE: THIS SIGN IS INTENDED TO BE INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF ARTICLE 600 OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER APPLICABLE LOCAL CODES. THIS INCLUDES PROPER GROUNDING AND BONDING OF THE SIGN. NOTICE TO SIGN INSTALLER:THE VOLTAGE AT THIS SIGN MUST BE BETWEEN 100 & 277 VOLTS FOR THIS SIGN TO OPERATE PROPERLY.NOTE: SPLICE CONNECTION BOX AND TRANSFORMER MUST NOT BE EXPOSED TO OUTSIDE WEATHER CONDITIONS.SHEET 4 OF 4 THIS SIGN TO BEAR UNDERWRITERS LABEL 100-277 VOLTS VIEWS WITH SCALES DIFFERENT THAN THE STATED SHEET SCALE WILL DISPLAY SPECIFICALLY IN THAT VIEW LABEL. DRAWING VIEWS SCALE CHART SHEET SCALE: 1:16 3/32" = 1'0" 1-1/2" = 1'0" 3" = 1'0" 1" = 1'0" 1/16" = 1'0" 1/4" = 1'0" 2" = 1'0" 1/2" = 1'0" 1/8" = 1'0" 4" = 1'0" 3/16" = 1'0" 3/8" = 1'0" 3/4" = 1'0" 1" = 1'0" 6" = 1'0" 1:192 1:128 1:96 1:64 1:48 1:32 1:24 1:16 1:12 1:8 1:6 1:4 1:3 1:2 1:1 UL NOTE THIS SIGN IS RATED FOR USE IN WET OR DAMP LOCATIONS ONLY