22 Prescott Street Floor and Elevation Plan - Updated 08.06.25APPLICABLE CODES: 2021 INTERNATIONAL RESIDENTIAL CODE2021 INTERNATIONAL MECHANICAL CODE2021 PLUMBING CODE2021 INTERNATIONAL ENERGY CODECITY OF SALEM ZONING ORDINANCE BUILDING CONSTRUCTION: ROOF - WOOD FRAME W/ ASPHALT SHINGLES ROOFINGFLOOR - WOOD FRAME EXTERIOR WALLS - VINYL SIDING, PVC TRIM W/ STUD BACKUPINTERIOR WALLS - WOOD STUD W/ BLUEBOARD & PLASTER FINISH BUILDING INFORMATION: 1. 2. 3. 4. 5. 6. 7. 8. 9. GENERAL NOTES: CONSTRUCTION TO BE IN ACCORDANCE WITH THE MA (STATE) BUILDING CODE, NINTH EDITION (FOR ONE & TWO FAMILY DWELLINGS) (MA) AND THE INTERNATIONAL RESIDENTIAL CODE (IRC 2021). THE CONTRACTOR IS RESPONSIBLE FOR ALL LABOR, MATERIALS, MEANS, AND METHODS OF CONSTRUCTION ASSOCIATED WITH THIS PROJECT. CONTRACTOR SHALL CONFIRM ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE DRAWINGS. THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE CONTRACT DRAWINGS, ANY DISCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER OR ENGINEER BEFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUBSTITUTIONS OF STRUCTURAL MATERIAL OR DETAILS FROM THOSE DEPICTED ON THE DRAWINGS MAY BE MADE ONLY WITH THE PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION, OR INSTALLATION. CONTRACTOR SHALL MAINTAIN SMOKE FREE PREMISES CLEAN AND FREE OF ALL TRASH DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILILNG, PAINT OVERSPRAY, ETC. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON CMPLETIOTN OF THE PROJECT. ALL MANUFACTURER'S PRINTED WARNINGS FOR HANDLING OF PRODUCTS MUST BE STRICTLY OBSERVED. SAVE ALL MATERIAL FOR OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB SAFETY DURING CONSTRUCTION INCLUDING BUT NOT LIMITED TO SHEETING, SHORING, AND GUYING STRUCTURES, BARRIERS, AND SIGNAGE. DO NOT SCALE THE DRAWINGS. DIMENSION STRINGS HAVE BEEN PROVIDED AND REPRESENT THE ACTUAL MEASUREMENT AS NOTED. LOCATIONS IS SEATING ON ZONING "R-2" -RESIDENTIAL 2-FAMILY ZONING REQUIREMENTS: FRONT SETBACKS 15'-0" REAR SETBACKS 30'-0" SIDE SETBACKS 10'-0" BUILDING HEIGHT 35'-0" REQUIRED:PROPOSED:ZONING REQUIREMENTS: MAX. BUILDING COVERAGE 35% MAX. NUMBER OF STORIES 2.5 REMAINS THE SAME REMAINS THE SAME REMAINS THE SAME REMAINS THE SAME 3 STORIES SHEET INDEX A0.0 COVER SHEET & PROJECT INFORMATION A0.1 GENERAL INFORMATION A0.2 PROPOSED SITE PLAN AEXST1.1 EXISTING - BASEMENT & 1ST FLOOR PLAN AEXST1.2 EXISTING 2ND & ATTIC FLOOR PLAN AEXST1.3 EXISTING-TOP OF ROOF AEXST 2.1 EXISTING LEFT & RIGHT EXTERIOR ELEVATIONS AEXST 2.2 EXISTING FRONT & REAR ELEVATIONS DM1.0 DEMOLITION PLAN - BASEMENT & 1ST FLOOR DM1.1 DEMOLITION PLAN - 2ND & 3RD FLOOR A1.0 PROPOSED - BASEMENT & 1ST FLOOR PLAN A1.1 PROPOSED 2ND & ATTIC FLOOR PLAN A1.2 PROPOSED TOP OF ROOF A2.1 PROPOSED FRONT & REAR EXTERIOR ELEVATIONS A2.0 PROPOSED FRONT & REAR EXTERIOR ELEVATIONS A3.0 PERSPECTIVE VIEWS A3.1 PERSPECTIVE VIEWS LOCUS MAP 22 Prescott St, Salem, MA 01970 CLIENT: 24 x 36 Date CONTRACTOR:DESIGNER: 8/6/2025 6:56:22 PM PROP. NEW DORMERS &INT.RENOVATION PROP. NEW DORMERS & INT.RENOVATION 07/10/2025 22 Prescott St, Salem, MA 01970 EXISTING CONDITION 07/10/2025 Arsenio Delarosa SCOPE: PROP. NEW DORMERS & INT. RENOVATION Arsenio.dlr@gmail.comPHONE# 978-979-8600 DELAROSA CONSTRUCTION ? LUX DESIGN GROUP 51 Main Street Topsfield, MA 01983Phone # 774-386-3441 SCOPE: PROP. NEW DORMERS & INT. RENOVATION 2 EXISTING AXONOMETRIC VIEW 1 PROPOSED AXONOMETRIC VIEW • • • • • • • • • • • • • • • • • • • • • • • GENERAL NOTES & SPECIFICATIONS 1. GENERAL REQUIREMENTS THESE DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. WHERE LACK OF INFORMATION, OR ANY DISCREPANCY SHOULD APPEAR IN THE DRAWINGS OR SPECIFICATIONS, REQUEST WRITTEN INTERPRETATION FROM THE ARCHITECT BEFORE PROCEEDING WITH THAT PORTION OF THE WORK. NO CHANGES, MODIFICATIONS OR DEVIATIONS SHALL BE MADE FROM THE DRAWINGS OR SPECIFICATIONS WITHOUT FIRST SECURING WRITTEN PERMISSION FROM THE ARCHITECT. ALL MATERIALS USED SHALL BE EQUAL TO OR EXCEED ALL APPLICABLE STATE OR LOCAL CODES AND REQUIREMENTS. CONTRACTOR SHALL REMOVE PROMPTLY AND LEGALLY ALL ACCUMULATED DEBRIS, PROTECT ALL EXPOSED PORTIONS OF WORK FROM ELEMENTS, AVOID OVER- LOADING STRUCTURE, AND SECURELY STORE ALL ITEMS TO BE USED FOR CONSTRUCTION. ALL EXISTING UTILITIES AND CITY SERVICES ARE TO BE MAINTAINED, KEPT IN SERVICE, AND PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING UNDERGROUND UTILITIES PRIOR TO EXCAVATION. ALL EXITS TO BE OPENABLE FROM THE INSIDE WITHOUT USE OF A KEY OR SPECIAL KNOWLEDGE. ALL WORK AS OUTLINED IN THESE DOCUMENTS, SHALL STRICTLY CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, THE EVENT OF A CONFLICT, THE MORE STRINGENT REQUIREMENT SHALL GOVERN AND BE MET. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL FEES, PERMITS, LICENSES, ETC., NECESSARY FOR PROPER COMPLETION OF THE WORK. ALL PERMITS, LICENSES, ETC SHALL BE OBTAINED BEFORE WORK IS BEGUN. THE CONTRACTOR SHALL GUARANTEE ALL WORKMANSHIP AND MATERIALS FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION OR AS OTHERWISE REQUIRED IN THE SPECIFICATIONS. PROVIDE ADEQUATE CONCEALED BLOCKING AND ANCHORING FOR ALL CEILING AND WALL MOUNTED EQUIPMENT, HARDWARE AND ACCESSORIES. WHEN A SYSTEM OR ASSEMBLY IS CALLED OUT FOR, ALL NECESSARY PARTS AND MATERIALS REQUIRED FOR A COMPLETE INSTALLATION/SYSTEM SHALL BE AND INSTALLED ACCORDING TO THE MANUFACTURERS INSTRUCTIONS. UNLESS OTHERWISE NOTED, ELECTRICAL CONDUITS, PLUMBING LINES, ETC., SHALL BE RUN CONCEALED AND FRAMING SHALL BE ADEQUATE SIZE TO ACCOMPLISH RESULT WITHOUT CAUSING ANY CHANGES IN THE WALL PLANE. COORDINATE WITH ALL TRADES THE LOCATIONS OF SLEEVES OR OTHER PRESET ACCESSORIES INVOLVING OTHER TRADES. IT IS THE INTENT OF THESE CONTRACT DOCUMENTS TO DEFINE A COMPLETE FINISHED FACILITY. ANY MATERIAL, SYSTEM, EQUIPMENTS OR ASSEMBLY WHICH NORMALLY WOULD BE REQUIRED SHALL BE PROVIDED AS IF SPECIFICALLY NOTED. WHEN WORK IS NOT CALLED OUT AS REQUIRED TO COMPLETE THE PROJECT, IT SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER AND BE OF THE BEST MATERIALS AND WORKMANSHIP. BEFORE FINAL DRAWINGS AND SPECIFICATIONS ARE ISSUED FOR CONSTRUCTION, THEY SHALL BE SUBMITTED TO ALL GOVERNING BUILDING AGENCIES TO INSURE THEIR COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. IF CODE DISCREPANCIES IN DRAWINGS AND/OR SPECIFICATIONS APPEAR, THE ARCHITECT SHALL BE NOTIFIED OF SUCH DISCREPANCIES IN WRITING BY THE CONTRACTOR OR BUILDING OFFICIAL, AND ALLOWED TO ALTER THE DRAWINGS AND SPECIFICATIONS SO AS TO COMPLY WITH GOVERNING CODES BEFORE CONSTRUCTION BEGINS. UPON WRITTEN RECEIPT OF APPROVAL FROM THE GOVERNING OFFICIAL, APPROVED FINAL DRAWINGS AND SPECIFICATIONS SHALL BE SUBMITTED TO THE CONTRACTOR BY IF CODE DISCREPANCIES ARE DISCOVERED DURING THE CONSTRUCTION PROCESS, THE ARCHITECT SHALL BE NOTIFIED AND ALLOWED AMPLE TIME TO REMEDY SAID DISCREPANCIES. ALL WORK PERFORMED SHALL COMPLY WITH ALL APPLICABLE LOCAL, STATE AND NATIONAL BUILDING CODES, ORDINANCES AND REGULATIONS, AND ALL OTHER AUTHORITIES HAVING JURISDICTION. ALL CONTRACTORS, SUPPLIERS, AND FABRICATORS SHALL BE RESPONSIBLE FOR THE CONTENT OF THE DRAWINGS, AND FOR THE SUPPLY AND DESIGN OF APPROPRIATE MATERIALS AND WORK PERFORMANCE. ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE HANDLED, APPLIED, INSTALLED, ERECTED, USED, CLEANED, AND CONDITIONED IN STRICT ACCORDANCE WITH THE MANUFACTURERS' REQUIREMENTS. ALL ALTERNATES ARE AT THE OPTION OF THE OWNER AND SHALL BE AT THE OWNER'S REQUEST, CONSTRUCTED IN ADDITION TO OR IN LIEU OF THE TYPICAL CONSTRUCTION, AS INDICATED ON THE DRAWINGS. Scale Date 8/6/2025 6:56:22 PM A0.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION GENERAL INFORMATION 07/10/2025 22 Prescott St, Salem, MA 01970• • • • • DESIGN LOADS: ROOF: DEAD LOAD: 15 PSF SNOW LOAD: 40 PSF (TABLE R301.2(5) ) LIVE LOAD: 20 PSF OR SNOW LOAD, WHICHEVER IS GREATER (R301.6 & TABLE R301.6) FLOOR: DEAD LOAD: 10 PSF LIVE LOAD: 40 PSF PER IRC TABLE R301.5 BALCONIES AND DECKS: DEAD LOAD: 10 PSF LIVE LOAD: 40 PSF PER IRC TABLE R301.5 SOIL PRESSURE: 2000 PSF (MINIMUM) PRIOR TO START OF CONSTRUCTION, VERIFY DESIGN LOADS WITH GOVERNING CODES AND SITE CONDITIONS. CHECK WITH LOCAL BUILDING AGENCIES FOR WIND, SEISMIC, SNOW AND OTHER SPECIAL LOADING CONDITIONS. IF DISCREPANCIES ARE DISCOVERED, ARCHITECT SHALL BE NOTIFIED BASIC WIND SPEED = 100 MPH PER TABLE R301.2(4) TOPOGRAPHIC EFFECTS = NO WEATHERING = SEVERE FROST LINE DEPTH = 48 ” TERMITE = MODERATE TO HEAVY PER FIGURE R301.2(6) ICE SHIELD UNDERLAYMENT REQUIRED = YES WIND EXPOSURE CATEGORY = SURFACE ROUGHNESS B, EXPOSURE B (PER R301.2.1.4) CLIMATE ZONE = 5A WIND-BORNE DEBRIS REGION = NO PER R202 HURRICANE-PRONE REGIONS = YES PER R202 PROTECTION OF OPENINGS = NO PER R301.2.1.2 HEADERS NOT SHOWN ON DRAWINGS: PER "HEADER SCHEDULE" THIS SHEET 1. SITE WORK A. PERFORM EXCAVATION, ACCORDING TO GOOD COMMON CONSTRUCTION PRACTICES, TO THE LINES, GRADES, AND ELEVATIONS INDICATED ON THE DRAWINGS. B. PROVIDE CONSISTENT COMPACTION OF THE TOP 8" OF SUB-GRADE, FILL, AND BACKFILL MATERIAL BENEATH STRUCTURES, WALKS, AND PAVEMENTS TO MEET THE STATED SOIL PRESSURE C. PROVIDE SOIL POISONING TO CONTROL TERMITES AS REQUIRED BY GOVERNING CODES. D. PROVIDE AND INSTALL VENTILATION FOR RADON GAS AS REQUIRED BY LOCAL BUILDING AGENCIES AND GOVERNING CODES E. TOP OF FOUNDATION ELEVATION IS ASSUMED TO BE 6" ABOVE THE FINAL GRADE AT THE OVERHEAD GARAGE DOOR OPENING. CHANGES IN THE FOUNDATION WALL ELEVATION RELATIVE TO THE FINAL GRADE WILL RESULT IN CHANGES TO THE FOUNDATION DRAWINGS AS WELL AS CHANGES TO THE WOOD AND PLASTICS A. LUMBER SHALL, IN ADDITION TO COMPLYING WITH GOVERNING CODES, COMPLY WITH: a. "PRODUCT USE MANUAL" OF THE WESTERN WOOD PRODUCTS ASSOCIATION FOR SELECTION AND USE OF PRODUCTS INCLUDED IN THAT MANUAL. b. "PLYWOOD SPECIFICATION AND GRADE GUIDE" OF THE AMERICAN PLYWOOD ASSOCIATION c. "STANDARD SPECIFICATIONS FOR GRADES OF CALIFORNIA REDWOOD LUMBER" OF THE REDWOOD INSPECTION BUREAU FOR REDWOOD. d. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS AND RECOMMENDATIONS FOR FIRE-RETARDATE AND PRESERVATIVE PRESSURE TREATED LUMBER AND PLYWOOD. e. WESTERN RED CEDAR LUMBER ASSOCIATION STANDARDS AND RECOMMENDATIONS FOR CEDAR. B. PROVIDE LUMBER AND MATERIALS MEETING OR EXCEEDING THE FOLLOWING STANDARDS OF QUALITY: a. FRAMING MEMBERS: • ALL INTERIOR OR OTHERWISE PROTECTED DIMENSION LUMBER SHALL BE SPRUCE— PINE—FIR (SPF) GRADE NO. 2 OR BETTER FOR RAFTERS, JOISTS, HEADERS, AND STUDS, UNLESS NOTED OTHERWISE. b. ALL HEADERS AND BEAMS SHALL BE FREE FROM SPLITS, CHECKS, AND SHAKES. c. SHEATHING: • ALL ROOF, FLOOR. AND WALL PANELS SHALL BE APA RATED EXPOSURE 1 SHEATHING COMPLYING WITH DOC PS 1 AND PSFULL 4X8 PANELS SHALL BE USED TO THE MAXIMUM EXTENT PRACTICABLE. • FLOOR SHEATHING 1. MINIMUM SPAN RATING: 32/16 2. MINIMUM THICKNESS: 23/32" 3. GLUED AND NAILED WITH TONGUE AND GROOVE JOINTS 4. FASTENERS: 8D COMMON AT 6" OC ALONG SUPPORTED EDGES AND 12" OC INTERMEDIATE 5. NOTE: USE APA RATED STURD—I—FLOOR OR ADVANTECH • ROOF SHEATHING 1. MINIMUM SPAN RATING: 32/16 2. MINIMUM THICKNESS: 5/8 IN T&G 3. GLUED AND NAILED WITH TONGUE AND GROOVE JOINTS 4. FASTENERS: 8D COMMON 5. FASTENER SP ACING GENERAL: 6" OC ALONG SUPPORTED EDGES AND 6" OC INTERMEDIATE. WITHIN 4 FT OF GABLE END WALLS: 4" OC • WALL SHEATHING 1. ALL EXTERIOR WALL SHEATHING (1/2" THICK PLYWOOD OR OSB SHEATHING PANELS) IS TO BE CLEANED FREE OF DEBRIS AND THEN NAILED TO THE FRAMING MEMBERS WITH 10D NAILS ON A 6" O.C. (EDGES) & 6" O.C. (FIELD) NAILING PATTERN, UNLESS OTHERWISE NOTED. SOLID BLOCK ALL JOINTS TYPICAL. LAY OUT SHEATHING SUCH THAT THERE IS A MINIMUM OF 16" EXTENDING IN EACH DIRECTION BEYOND THE FLOOR FRAMING. IF THIS CANNOT BE ACHIEVED THEN STRAPPING MUST BE USED. CONTACT ARCHITECT FOR STRAPPING SPACING AND DEVELOPMENT LENGTH BEFORE INSTALLATION. • UNDER LAYMENT: 1/8" LUAN-UNDERLAYMENT GRADE. (AT VINYL ONLY) • PROPER ORIENTED STRAND BOARD MAY BE SUBSTITUTED FOR PLYWOOD. A. HOLD—DOWNS AND FRAMING CONNECTORS a. ALL STRUCTURAL FRAMING CONNECTIONS, UNLESS SPECIFICALLY NOTED OTHERWISE, SHALL BE "STRONG TIE" AS MANUFACTURED BY THE SIMPSON CO. IN ACCORDANCE WITH 'WOOD CONSTRUCTION CONNECTORS" CATALOG C-2009. ALL FASTENERS (TYPE. SIZE, AND QUANTITY) SPECIFIED IN SIMPSON'S CONNECTOR SCHEDULE SHALL BE INSTALLED. THE ABBREVIATION "SST" ON THE DRAWINGS INDICATE FASTENERS/CONNECTORS AS MANUFACTURED BY SIMPSON STRONG b. ALL CONNECTORS AND FASTENERS FOR PRESSURE PRESERVATIVE TREATED WOOD SHALL BE SHOP—COATED AND/OR STAINLESS STEEL TO SUIT THE SPECIFIC EXPOSURE(S) AND WOOD PRESERVATIVE(S) IN ACCORDANCE WITH SIMPSON STRONG — TIE RECOMMENDATIONS. THE CONTRACTOR SHALL REVIEW DOCUMENTATION CONTAINED IN THE SIMPSON STRONG — TIE CATALOG AND PROVIDE CONNECTORS AND FASTENERS THAT ARE ACCEPTABLE FOR THE EXPOSURE AND CHEMICAL PRESERVATIVES USED ON THE PROJECT. THE REVIEW SHALL CONSIDER THE TYPE OF PRESERVATIVE(S), PRESERVATIVE RETENTION LEVEL(S), AND EXPOSURE ENVIRONMENT(S). c. ALL CONNECTORS AND FASTENERS FOR EXPOSED PORCH AND DECK FRAMING IN COASTAL ENVIRONMENTS SHALL BE STAINLESS STEEL. d. INSTALL JOIST AND BEAM HANGERS CAPABLE OF SUPPORTING THE MAXIMUM ALLOWABLE LOAD OF JOIST OR BEAM BEING SUPPORTED. D. LAMINATED VENEER LUMBER (LVL) a. LAMINATED VENEER LUMBER SHALL BE 1.9E TJ MICROLAM LVL BY TRUS JOIST, OR APPROVED EQUAL, UNLESS OTHERWISE INDICATED. b. PARALLEL STRAND LUMBER UMRFR (PSL): PARALLEL STRAND LUMBER SHALL BE 1.8E PARALLAM PSL BY TRUS JOIST, OR APPROVED EQUAL, UNLESS OTHERWISE INDICATED. c. ENGINEERED WOOD JOISTS: JOISTS AND ACCESSORIES INCLUDING RIM JOISTS SHALL BE THE PRODUCTS OF TRUS JOIST, OR APPROVED EQUAL. d. USE EXTERIOR GRADE MICRO LAM IN ALL AREAS SUBJECT TOMOISTURE. E. PLATE CONNECTED WOOD TRUSSES a. DESIGN AND FABRICATION OF TRUSSES SHALL BE SUBJECT TO THIRD PARTY INSPECTION b. TRUSSES SHALL BE DESIGNED FOR ALL COMBINATIONS OF DEAD, LIVE, WIND, AND SNOW LOADS AS REQUIRED UNDER THE REFERENCED CODES. SNOW LOADING SHALL INCLUDE UNIFORM, UNBALANCED, DRIFTING, AND/OR SLIDING TO SUIT EACH CONDITION c. THE TRUSS SUPPLIER SHALL DESIGN ALL REQUIRED TRUSS CONFIGURATIONS, INCLUDING BUT NOT LIMITED TO COMMON, GIRDER, JACK, HIP, VALLEY, AND SPECIAL d. IF THE TRUSS SUPPLIER PROPOSES TO USE DIMENSION LUMBER OVERFRAMING TO SUIT VARIOUS CONDITIONS IN ADDITION TO ANY SUCH LOCATIONS SHOWN ON THE DRAWINGS, THAT WORK SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR SUCH THAT ALL WORK IS INCLUDED UNDER THE CONTRACT e. TRUSSES SHALL BE DESIGNED SUCH THAT BUCKLING OF ANY INDIVIDUAL MEMBERS IS RESISTED INTERNALLY BY THE INDIVIDUAL TRUSS THROUGH SUITABLE MEANS, SUCH AS T- OR LBRACING f. TRUSSES SHALL BE ERECTED IN ACCORDANCE WITH TPI AND TRUSS MANUFACTURER PUBLICATIONS. PROVIDE ALL TEMPORARY BRACING AS SHOWN ON SUBMITTALS AND IN APPLICABLE PUBLICATIONS g. PROVIDE WOOD TRUSSES ABLE TO SUSTAIN THE STATED LOADS FOR THE SPANS, PROFILES, AND ARRANGEMENT SHOWN ON THE DRAWINGS. TRUSS LAYOUT IS SCHEMATIC ONLY. TRUSS ANUFACTURER AND/OR ENGINEER SHALL BE RESPONSIBLE FOR THE DESIGN AND SPACING OF ALL TRUSSES. CONTRACTOR TO SUBMIT TRUSS DRAWINGS AND/OR ROOF FRAMING DRAWINGS TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. h. PROVIDE HURRICANE CLIPS, HOLD DOWNS, STRAPS AND OTHER CONNECTORS AS REQUIRED BY TRUSS MANUFACTURER. DESIGN F ALL CONNECTORS BY TRUSS MANUFACTURER. F. PRESSURE TREATED LUMBER a. DIMENSION LUMBER FOR THE FOLLOWING LOCATIONS SHALL BE PRESSURE PRESERVATIVE—TREATED (PT) SOUTHERN PINE #2 OR BETTER: • PORCHES, DECKS, AND OTHER FRAMING EXPOSED TO THE WEATHER • INTERIOR WOOD JOISTS WITHIN 18" OF EXPOSED GROUND • INTERIOR TIMBER OR BUILT—UP BEAMS WITHIN 12" OF EXPOSED GROUND • SILL PLATES • ALL WALL FRAMING AND SHEATHING LESS THAN 6" FROM EXPOSED GROUND b. ALL PT LUMBER TO BE TREATED WITH A PENETRATING WATER REDUCER (SUCH AS BOILED LINSEED OIL) IN ORDER TO INCREASE THE LIFE OF THE STRUCTURE. ALL PT LUMBER IS TO HAVE ANY CUT ENDS FIELD TREATED WITH WOLMAN'S WOODLIFE COPPERCOAT. G. WOOD INSTALLATION a. UNLESS NOTED OTHERWISE, PROVIDE: • DOUBLE HEADER JOISTS AND TRIMMERS AT ALL FLOOR OPENINGS. • DOUBLE JOISTS UNDER ALL PARTITIONS PARALLEL TO JOISTS. • DOUBLE JOISTS OR JOISTS AT 12" O.C. AT ALL KITCHENS AND BATHS. • PROVIDE HEADERS PER "HEADER SCHEDULE" OR AS INDICATED ON THE DRAWINGS. • ONE ROW OF 1X3 CROSS-BRIDGING OR METAL BRIDGING FOR EACH 8'-0" OF JOIST SPAN b. STUD SPACING AT ALL EXTERIOR AND BEARING WALLS SHALL BE 16" O.C. MINIMUM. c. STUD WALLS SHALL NOT EXCEED THE FOLLOWING HEIGHTS WITHOUT CONTINUOUS LATERAL SUPPORT PERPENDICULAR TO THE PLANE OF THE WALL AT THE STATED HEIGHT OR LESS. STUDS SHALL BE CONTINUOUS BETWEEN POINTS OF LATERAL SUPPORT. • BEARING WALLS: 1. 2X4: 10'-0" 2. 2X6: 12'-0' • NON-BEARING WALLS: 1. 2X4: 14'-0" 2. 2X6: 20'-0" d. UNLESS NOTED OTHERWISE, RAFTERS, CEILING JOISTS, COLLAR TIES, AND PURLINS SHALL BE SIZED AND SPACED IN ACCORDANCE WITH FHA REQUIREMENTS OR GOVERNING CODES, WHICHEVER IS MORE RESTRICTIVE. e. STAIR CONSTRUCTION SHALL CONSIST OF (3)2X12 STRINGERS, 5/4" OR 2X THICK TREAD AND 3/4" THICK RISERS OR, SHALL BE FABRICATED BY COMPONENT MANUFACTURER. f. ALL WOOD PLATES BEARING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED. AT EXTERIOR WALLS INSTALL PLATES OVER FOAM SILL SEALER GASKET. g. PROVIDE 2" NOMINAL PRESSURE TREATED LUMBER OVER 6 MIL. STABILIZED POLYETHYLENE BENEATH FULL BEARING OF WOOD BEAMS BEARING ON CONCRETE OR MASONRY. h. PROVIDE SIMPSON STRONG WALL GARAGE PORTAL SYSTEM AROUND ALL OVERHEAD DOORS WITH A WIDTH GREATER THAN 8'. INSTALL GARAGE PORTAL SYSTEM PER MANUFACTURERS RECOMMENDED GUIDELINES. i. ALL FRAMING SHALL BE ERECTED TRUE TO LINE. PLUMB AND LEVEL, AND SHALL BE FASTENED/HUNG TO DEVELOP THE FULL STRENGTH OF THE ASSEMBLY IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. j. DIMENSION LUMBER BEAMS FRAMING INTO FLUSH STEEL AND LVL BEAMS SHALL BE SET 1/4"ABOVE THE TOP OF BEAM TO ACCOMMODATE SHRINKAGE. k. ALL CONTINUOUS POSTS SHALL BE LATERALLY BRACED IN BOTH DIRECTIONS AT EACH FLOOR AND CEILING LEVEL. l. ALL ENGINEERED PRODUCTS SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH PRODUCT MANUFACTURERS' SPECIFICATIONS AND INSTALLATION DETAILS. WITH THE EXCEPTION OF MANUFACTURER-PROVIDED KNOCKOUTS, NO HOLES SHALL BE FIELD- DRILLED IN MEMBERS. IF HOLES ARE REQUIRED. NOTIFY THE ARCHITECT PRIOR TO ORDERING AFFECTED MEMBERS. d. FLOOR SHEATHING SHALL BE GLUED AND NAILED. e. PROVIDE 2X WOOD BLOCKING OR RIM JOIST AT ALL SAWN LUMBER FLOOR JOIST SUPPORT POINTS. f. PROVIDE BLOCKING OR RIM BOARD AT ALL ENGINEERED FLOOR JOIST SUPPORT POINTS. USE JOIST MANUFACTURER'S PRODUCTS AND COMPLY WITH JOIST MANUFACTURER'S INSTALLATION DETAILS. g. PROVIDE 2X SOLID BLOCKING AT ALL RAFTER TAILS. h. SIZES OF DIMENSION LUMBER ARE NOMINAL. ALL LUMBER SHALL BE SURFACED FOUR SIDES, UNLESS NOTED OTHERWISE. i. STRUCTURAL MEMBERS SHALL NOT BE IMPAIRED OR UNDERMINED BY IMPROPER CUTTING OR DRILLING. j. ALL BUILT-UP LVL BEAMS SHALL BE ASSEMBLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. H. THERMAL AND MOISTURE PROTECTION A. PROVIDE THERMAL BUILDING INSULATION AT ASSEMBLIES ADJACENT TO EXTERIOR OR UNHEATED SPACES MEETING THE REQUIREMENTS OF GOVERNING CODES AND, UNLESS NOTED OTHERWISE, MEETING THE FOLLOWING MINIMUM REQUIREMENTS: a. FOUNDATIONS: 1 1/2"EXTRUDED POLYSTYRENE (R-8.4) b. WALLS: GLASS FIBER BATT (R-20) U.N.O. c. FLOORS: GLASS FIBER BATT (R-30) d. CEILINGS: GLASS FIBER BATT (R-49) e. INSTALL CONTINUOUS BLANKETS WITHOUT HOLES FOR ELECTRICAL BOXES, LIGHTING FIXTURES, OR HEATING DUCTWORK. B. INSTALL 6 MIL. STABILIZED POLYETHYLENE VAPOR BARRIER AGAINST INTERIOR FACE OF ALL THERMAL INSULATION. C. WATERPROOF FOUNDATION WALLS AT EXCAVATED AREAS FROM FOOTING TO FINISHED GRADE WITH TWO COATS OF ASPHALT BASED WATERPROOFING COMPOUND. PROVIDE DRAINAGE MAT AND TIE INTO FOUNDATION DRAINS. D. ROOFING SHALL BE 240 LB. (MINIMUM) COMPOSITION SHINGLES INSTALLED OVER 30 LB. ROOF FELT ON ROOF SHEATHING. MINIMUM SLOPE, FASTENERS, UNDER LAYMENT, AND EXPOSURE ACCORDING TO MANUFACTURERS' RECOMMENDATIONS. E. PROVIDE FLASHING AND SHEET METAL REQUIRED TO PREVENT PENETRATION OF WATER THROUGH THE EXTERIOR SHELL OF THE BUILDING. IN ADDITION TO COMPLYING WITH GOVERNING CODES, COMPLY WITH PERTINENT RECOMMENDATIONS CONTAINED IN THE CURRENT EDITION OF "ARCHITECTURAL SHEET METAL MANUAL" PUBLISHED BY SMCNA. ALL IRON SHEET METAL FLASHING SHALL BE HOT-DIPPED GALVANIZED COMPLYING WITH ASTM A93. F. PROVIDE GUTTERS AND DOWNSPOUTS TO PROVIDE POSITIVE ROOF AND SITE DRAINAGE. G. PROVIDE ATTIC AND ROOF VENTILATION AS REQUIRED BY GOVERNING CODES AND AS SHOWN ON THE DRAWINGS. PROVIDE APPROPRIATE SOFFIT AND ROOF VENTS. H. SKYLIGHTS SHALL BE SELECTED BY THE CONTRACTOR AND APPROVED BY THE OWNER. INSTALL SKYLIGHTS ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS. I. INSTALL WATER AND ICE BARRIER (BITUTHENE OR EQUAL) OVER ROOF SHEATHING AT ALL EAVES AND VALLEYS. INSTALL PER CODE AND PER MANUFACTURER'S RECOMMENDATIONS. I. DOORS AND WINDOWS A. EXTERIOR DOORS SHALL BE SELECTED BY THE OWNER. B. HOUSE-TO-GARAGE DOORS SHALL BE FIRE RATED DOORS APPROVED BY GOVERNING CODES. FACE DESIGN TO BE SELECTED BY THE OWNER. C. INTERIOR DOORS SHALL BE SELECTED BY THE OWNER. D. EXTERIOR WINDOWS SHALL BE ALUMINUM OR VINYL CLAD WOOD WINDOWS MANUFACTURED BY: PELLA CORP. E. GLAZING IN ALL DOORS AND WINDOWS SHALL COMPLY WITH GOVERNING CODES. PROVIDE TEMPERED SAFETY GLASS IN ALL CODE REQUIRED LOCATIONS. F. INSTALL EGRESS WINDOW UNITS IN ACCORDANCE WITH GOVERNING CODES. G. DOOR AND WINDOW SIZES INDICATED OR DRAWINGS ARE AS FOLLOWS: 36"X80" REPRESENTS A DOOR OR WINDOW 3'-0" WIDE X 6'-8" HIGH. JAMB DEPTH TO BE COORDINATED BY THE CONTRACTOR. H. FINISH HARDWARE SHALL BE SELECTED BY THE OWNER. INSTALL HARDWARE IN ACCORDANCE WITH GOVERNING CODES. J. FINISHES A. GYPSUM WALLBOARD, UNLESS NOTED OTHERWISE, SHALL BE PROVIDED AS FOLLOWS: a. EXTERIOR WALLS: ONE LAYER 1/2" REGULAR WALLBOARD TO INTERIOR FACE. b. INTERIOR WALLS: ONE LAYER 1/2" REGULAR WALLBOARD EACH FACE. c. CEILING: ONE LAYER 1/2" REGULAR WALLBOARD ON 1X3 WOOD STRAPPING AT 16" O.C. d. GARAGE/HOUSE COMMON WALLS / CEILINGS: ONE LAYER 5/8" TYPE "X" (FIRE RATED) WALLBOARD EACH FACE. e. AT MULTIFAMILY RESIDENCES (2 OR MORE FAMILIES): ALL WALL AND CEILING BOARD TO BE ONE LAYER 5/8" TYPE "X" (FIRE RATED) WALLBOARD EACH FACE. f. BATHS: MOISTURE AND MOLD RESISTANT WALLBOARD AT ALL WALLS AND CEILINGS. g. PROVIDE TYPE X IN MULTIFAMILY RESIDENCES. h. PROVIDE CEMENT BOARD AS SUBSTRATE FOR CERAMIC TILE. B. PROVIDE METAL CORNER BEAD AND TRIM AT ALL LOCATIONS RECOMMENDED BY THE GYPSUM WALLBOARD MANUFACTURER. C. TAPE, FLOAT, AND SAND JOINTS AND FASTENERS OF GYPSUM WALLBOARD WITH THREE COATS OF JOINT COMPOUND AS REQUIRED TO OBTAIN A UNIFORMLY SMOOTH SURFACE. D. FINISHES SHALL BE SELECTED BY THE OWNER. K. PLUMBING, MECHANICAL, AND ELECTRICAL A. PLUMBING, MECHANICAL, AND ELECTRICAL INFORMATION AND LAYOUTS SHOWN ON THE DRAWINGS IS SCHEMATIC IN DESIGN, AND SHALL BE REVIEWED BY SUB- CONTRACTORS, SUPPLIERS, AND BUILDING OFFICIALS FOR COMPLIANCE WITH GOVERNING CODES AND GOOD COMMON CONSTRUCTION PRACTICES. THE ARCHITECT SHALL BE NOTIFIED BY THE CONTRACTOR OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. B. PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL BE SELECTED BY THE OWNER. C. DESIGN AND INSTALLATION OF PLUMBING, MECHANICAL, AND ELECTRICAL EQUIPMENT SHALL BE THE RESPONSIBILITY OF THE APPROPRIATE LICENSED CONTRACTORS AND SUBCONTRACTORS. DESIGN SHALL BE SUBMITTED FOR OWNER'S REVIEW PRIOR TO ORDERING AND INSTALLATION OF EQUIPMENT. D. SERVICE PANELS SHALL BE SELECTED BY THE ELECTRICAL SUBCONTRACTOR. E. ALL HVAC EQUIPMENT SHALL BE INDIVIDUALLY SWITCHED. F. ALL OUTDOOR, BATH, AND GARAGE AND SPA WALL RECEPTACLES SHALL BE PROVIDED WITH GROUND FAULT CIRCUIT PROTECTION IN ACCORDANCE WITH GOVERNING CODES. G. DRYER AND RANGE HOOD VENTS SHALL BE EXTENDED TO THEEXTERIOR. H. PROVIDE PLUMBING VENTS IN ACCORDANCE WITH GOVERNING CODES. MINIMIZE NUMBER AND LOCATE FOR MINIMAL VISUAL IMPACT. I. INSTALL TYPE AND NUMBER OF SMOKE DETECTORS IN ACCORDANCE WITH GOVERNING CODES & UL217. PROVIDE HARDWIRED AND INTERCONNECTED SMOKE AND CO DETECTORS WITH BATTERY BACKUP PER CODE REQUIREMENTS & AS DIRECTED BY THE LOCAL BUILDING DEPT. J. CONNECT WATER, GAS, AND ELECTRIC SERVICES IN ACCORDANCE WITH GOVERNING CODES. K. ELECTRICAL SYSTEM TO BE DESIGN/BUILD BY ELECTRICAL CONTRACTOR. ALL ELECTRICAL CALCULATIONS AND WIRE SIZE TO BE PROVIDED BY A LICENSED ELECTRICAL CONTRACTOR. CONTRACTOR TO VERIFY LOCATION, FIXTURE TYPES AND EQUIPMENT WITH OWNER PRIOR TO PURCHASE AND INSTALLATION. PROVIDE POWER FOR ALL APPLIANCES. LOCATE NEW ELECTRICAL DEVICES PER NEC REQUIREMENTS & OWNER'S REQUIREMENTS. RECONNECT EXISTING FIXTURES TO NEW SWITCH LOCATIONS AS REQUIRED IN THE FIELD. PROVIDE DIMMERS AS DIRECTED BY OWNER. A/V, CATV, TELEPHONE AND OTHER LOW VOLTAGE WIRING NOT SHOWN. SYSTEM TO BE DESIGN/BUILD. CONTACT OWNER FOR LOCATIONS OF ALL LOW VOLTAGE WIRING. L. MECHANICAL SYSTEM TO BE DESIGN/BUILD BY MECHANICAL CONTRACTOR. MECHANICAL SYSTEM TO BE INSTALLED BY A LICENSED MECHANICAL CONTRACTOR. VERIFY EQUIPMENT TYPE WITH OWNER PRIOR TO PURCHASE AND INSTALLATION. M. PLUMBING SYSTEM TO BE DESIGN/BUILD BY PLUMBING CONTRACTOR. PLUMBING SYSTEM TO BE INSTALLED BY A LICENSED PLUMBING CONTRACTOR. N. ALL EXISTING UTILITIES AND CITY SERVICES ARE TO BE MAINTAINED, KEPT IN SERVICE, AND PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. O. UNLESS OTHERWISE NOTED, ELECTRICAL CONDUITS, PLUMBING LINES, ETC., SHALL BE RUN CONCEALED AND FRAMING SHALL BE ADEQUATE SIZE TO ACCOMPLISH RESULT WITHOUT CAUSING ANY CHANGES IN THE WALL PLANE. 10. MISCELLANEOUS A. THIS SET OF CONSTRUCTION DRAWINGS IS INTENDED FOR DESIGN INTENT ONLY. ALTHOUGH MANY JURISDICTIONS WILL ACCEPT THESE DRAWINGS AS SUFFICIENT FOR A CONSTRUCTION PERMIT, THESE DRAWINGS ARE NOT INTENDED, AND SHOULD NOT BE CONSTRUED, AS A COMPLETE SET OF CONSTRUCTION DRAWINGS. THESE DRAWINGS WILL HAVE TO BE ADAPTED TO MEET LOCAL ZONING AND/OR SITE CONDITIONS AND ADDITIONAL DETAILING WILL NEED TO BE COMPLETED ON SITE BY THE BUILDER. B. INSTALL PREFABRICATED FIREPLACE UNITS AS SHOWN ON DRAWINGS. a. FIREPLACE UNITS SHALL BE "HEAT-N-GLO" OR AS APPROVED BY OWNER. b. CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER INSTALLATION AS RECOMMENDED BY THE MANUFACTURER AND AS REQUIRED BY GOVERNING CODES, INCLUDING MANTEL AND HEARTH DESIGN AND LOCATION. c. HEARTH SHALL BE OF NON-COMBUSTIBLE MATERIAL. C. ROOM SIZES SHOWN ON THE PLANS INDICATE ROOM DIMENSIONS PRIOR TO INSTALLATION OF GYPSUM WALL BOARD. GYPSUM WALL BOARD THICKNESS MUST BE SUBTRACTED FROM ROOM SIZES INDICATED FOR ACTUAL ROOM DIMENSIONS AND ARE SUBJECT TO CHANGE. 11. SUBMITTALS A. SUBMIT ROOF TRUSS AND/OR RAFTER LAYOUT PLAN AS COMPLETED BY THE MANUFACTURER FOR REVIEW PRIOR TO ORDERING ROOF TRUSSES AND/OR ROOF LUMBER PACKAGE. ALLOW ARCHITECT FIVE BUSINESS DAYS FOR COMPLETE REVIEW. B. SUBMIT FLOOR TRUSS LAYOUTS SHOWING BEAM LOCATIONS, JOIST LAYOUT, LOCATIONS OF CONTINUOUS DUCT CHASES, AND MAXIMUM DUCT SIZE IN EACH CHASE. ALLOW ARCHITECT FIVE BUSINESS DAYS FOR COMPLETE REVIEW. C. ARCHITECT WILL NOT BE RESPONSIBLE FOR ANY ERRORS IN THE ROOF AND/OR FLOOR FRAMING WITHOUT THE OPPORTUNITY TO REVIEW THE ROOF AND/OR FLOOR FRAMING LAYOUTS. FRAMING LAYOUTS, MEMBER SIZES, AND FLOOR/ROOF PENETRATIONS INDICATED ON THE DRAWINGS ARE FOR DESIGN INTENT ONLY. FINAL LAYOUTS SHALL BE THE RESPONSIBILITY OF BUILDER. SHED A SHED B EXISTING HOUSE PO R C H PO R C H DRIVEWAY DRIVEWAY CURB CU R B WA L K CURBCURBWALK PR E S C O T T S T R E E T CU R B GR A N I T E CO N C R E T E W A L K PROPERTY LINE REQUIRED SETBACK REQUIRED REAR SETBACKS 30'-0" RE Q . S I D E S E T B A C K S 10 ' - 0 " RE Q . S I D E S E T B A C K S 10 ' - 0 " REQ. FRONT SETBACKS 15'-0" PROPOSED NEW STAIR 10'-4" 3' - 1 1 " 10 1 / 2 " 1'-5" 10 ' - 1 1 / 4 " 13'-8 3/4" Scale Date 8/6/2025 6:56:23 PM 1/4" = 1'-0" A0.2 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PROPOSED SITE PLAN 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 PROPOSED ARCHITECTURAL SITE PLAN DN UP UP UP AEXST 2.12 AEXST 2.2 2 AEXST 2.1 1 AEXST 2.2 1 LIVING ROOM DINING AREA KITCHEN PANTRY HALLWAY FOYER ROOM-1 BATHROOM BEDROOM-1 ROOM-2 CLOSET PORCH PORCH 5'-11 1/2" 22 ' - 1 0 1 / 2 " 8' - 3 " 5' - 1 0 1 / 4 " 8' - 9 1 / 4 " 3'-2" 5'-10" 16 ' - 0 1 / 4 " 12 ' - 7 1 / 4 " 3' - 5 1 / 4 " AEXST 2.12 AEXST 2.2 2 AEXST 2.1 1 AEXST 2.2 1 MECHANICAL ROOM BATHROOM ROOM-1 ROOM - 4 ROOM-2 CORRIDOR ROOM - 3 1/4" = 1'-0"2 EX. 1ST FLOOR Scale Date 8/6/2025 6:56:23 PM 1/4" = 1'-0" AEXST1.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION EXISTING - BASEMENT &1ST FLOOR PLAN 07/10/2025 22 Prescott St, Salem, MA 01970 Scale Date 8/6/2025 6:56:23 PM 1/4" = 1'-0" AEXST1.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION EXISTING - BASEMENT &1ST FLOOR PLAN 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 EXISTING BASEMENT FLOOR DN DN AEXST 2.12 AEXST 2.2 2 AEXST 2.1 1 AEXST 2.2 1 ROOM-1 LIVING AREA DINING AREA KITCHEN HALLWAY CLOSET BEDROOM ROOM-2 BATHROOM DECK DECK PANTRY 22 ' - 1 0 1 / 2 " 5'-11 1/2" 16 ' - 7 3 / 4 " 5'-10" 3'-2" AEXST 2.12 AEXST 2.2 2 AEXST 2.1 1 AEXST 2.2 1 Scale Date 8/6/2025 6:56:23 PM 1/4" = 1'-0" AEXST1.2 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION EXISTING 2ND & ATTICFLOOR PLAN 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 EX. 2ND FLOOR 1/4" = 1'-0"2 EX. ATTIC FLOOR AEXST 2.12 AEXST 2.2 2 AEXST 2.1 1 AEXST 2.2 1 Scale Date 8/6/2025 6:56:23 PM 1/4" = 1'-0" AEXST1.3 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION EXISTING-TOP OF ROOF 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 EX. TOP OF ROOF EX. 1ST FLOOR0' - 0" EX. 2ND FLOOR 9' - 4" EX. ATTIC FLOOR18' - 4" EX. TOP OF ROOF 29' - 8 7/8" EX. 1ST FLOOR0' - 0" EX. 2ND FLOOR 9' - 4" EX. ATTIC FLOOR18' - 4" EX. TOP OF ROOF 29' - 8 7/8" 1/4" = 1'-0"2 EXISTING RIGHT ELEVATION 1/4" = 1'-0"1 EXISTING LEFT ELEVATION Scale Date 8/6/2025 6:56:28 PM 1/4" = 1'-0" AEXST 2.2 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION EXISTING FRONT & REARELEVATIONS 07/10/2025 22 Prescott St, Salem, MA 01970 EX. 1ST FLOOR0' - 0" EX. 2ND FLOOR 9' - 4" EX. ATTIC FLOOR18' - 4" EX. TOP OF ROOF 29' - 8 7/8" EX. 1ST FLOOR0' - 0" EX. 2ND FLOOR 9' - 4" EX. ATTIC FLOOR18' - 4" EX. TOP OF ROOF 29' - 8 7/8" Scale Date 8/6/2025 6:56:32 PM 1/4" = 1'-0" AEXST 2.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION EXISTING LEFT & RIGHTEXTERIOR ELEVATIONS 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"2 EXISTING REAR ELEVATION 1/4" = 1'-0"1 EXISTING FRONT ELEVATION DN UP DN UP DEMO LEGEND: EXISTING WALL TO REMAIN DEMO WALL OR COMPONENT DEMO DOOR Scale Date 8/6/2025 6:56:32 PM 1/4" = 1'-0" DM1.0 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION DEMOLITION PLAN -BASEMENT & 1ST FLOOR 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 1ST FLOOR DEMOLITION 1/4" = 1'-0"2 BASEMENT FLOOR DEMOLITION DN DN DEMO LEGEND: EXISTING WALL TO REMAIN DEMO WALL OR COMPONENT DEMO DOOR Scale Date 8/6/2025 6:56:33 PM 1/4" = 1'-0" DM1.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION DEMOLITION PLAN - 2ND& 3RD FLOOR 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 2ND FLOOR DEMOLITION 1/4" = 1'-0"2 3RD FLOOR DEMOLITION DN UP Vent Hood DWREF UP WD A2.1 2 A2.1 1 A2.0 1 A2.0211 SF HIS CLOSET 208 46 SF PRIMARY BATHROOM 209 31 SF HER CLOSET 210 175 SF DINING AREA 211 197 SF KITCHEN 212 156 SF PRIMARY BEDROOM 213 162 SF BEDROOM-1 214 177 SF LIVING AREA 215 3'-0" DN 2' - 3 1 / 4 " 6'-10 1/2" 3'-8 1/2" 3'-0" 11'-9" 10 1 / 2 " 3' - 1 1 " 5'-11 1/2" 8' - 3 " 5' - 1 0 1 / 4 " 8' - 9 1 / 4 " 22 ' - 1 0 1 / 2 " 3'-2" 5'-10" 12 ' - 7 1 / 4 " 3' - 5 1 / 4 " 16 ' - 4 3 / 4 " PROPOSED NEW STAIR EGRESS FOR 2ND FLOOR UNIT E E G-T E E JJ C E C C B A B E F A2.1 2 A2.1 1 A2.0 1 A2.02 28 SF CLOSET 239 262 SF BEDROOM 240 27 SF CLOSET 241 55 SF BATHROOM 242 440 SF MECHANICAL ROOM 243 84 SF LAUNDRY ROOM 244 3'-2"1".3'-2". 4'-0" 37 SF STORAGE/MECHANICAL 245 L LLLL L L L L FLOOR PLAN LEGEND: EXISTING WALL TO REMAIN PROPOSED NEW WALL NO WORK THIS AREA EXISTING DOOR NEW DOOR SP PHOTO SENSITIVE SMOKE DETECTOR (HARD WIRE) SCO COMBINATION PHOTO SENSITIVE SMOKE/CARBON MONOXIDE DETECTOR(HARD WIRE) HEAT DETECTOR (HARD WIRE)HT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. GENERAL CONSTRUCTION NOTES: USE METAL JOISTS AND BEAM HANGERS FOR ALL FLUSH FRAMED CONDITIONS, USE STEEL CONNECTION ASSEMBLIES TO FULLY DEVELOPE THE CONNECTED MEMBERS. ALL BEAMS AND LINTELS TO BE CONNECTED TO WOOD POSTS WITH MINIMUM 12 GA. STEEL POST CAPS BY "SIMPSON" OR EQUAL. THE MINIMUM INTERIOR HEADER SIZE IS 2 @ 2X6 TYPICAL, UNLESS NOTED OTHERWISE. (U.N.O) THE MINIMUM EXTERIOR HEADER SIZE IS 3 @ 2X8 TYPICAL, U.N.O. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED ALL STUD WALL DIMENSIONS ARE TO FACE OF STUD U.N.O. MASONRY/CONCRETE DIMENSIONS ARE TO FACE OF MASONRY/CONCRETE. CEILING HEIGHTS ARE SUBFLOOR TO UNDERSIDE OF FINISHED CEILING. ALL EXTERIOR STUDS ARE 5-1/2" U.N.O & ALL INTERIOR STUDS ARE 3-1/2" U.N.O. REFERT O STRUCTURAL DRAWINGS & SPECIFICATIONS FOR ADDITIONAL, STRUCTURAL, INFORMATION. CONTACT ARCHITECT WITH ANY FOUND DISCREPENCIES OR CONFLICTS. ALL DOORS AND CASED OPENINGS ARE TO BE LOCATED 5" FROM ADJACENT WALL FRAMING TO DOOR OPENING OR CENTERED ON THE WALL WHERE LOCATED, U.N.O. INTERIOR THRESHOLDS AT WOOD/TILE & WOOD/CARPET TRANSITION TO BE WOOD TO MATCH WOOD FLOORING. ALL CLOTHING CLOSETS TO HAVE A HANGING ROD AT 5'-6" AFF WITH EDGEBANDED PAINTED PLYWOOD SHELF ABOVE U.N.O. LINEN CLOSETS TO HAVE (5) 16" DEEP EDGEBANDED PAINTED PLYWOOD SHELVES ON LEDGERS, FINISHES WITHIN CLOSETS TO MATCH ADJACENT ROOMS. ALL WINDOW AND DOOR HEIGHTS TO MATCH U.N.O. (ALIGN FINISH HEAD TRIM, TYPICAL). Scale Date 8/6/2025 6:56:33 PM 1/4" = 1'-0" A1.0 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PROPOSED - BASEMENT& 1ST FLOOR PLAN 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 PROPOSED 1ST FLOOR 1/4" = 1'-0"2 PROPOSED BASEMENT PLAN NOTE: EXISTING HOUSE SF: 2400 SF PROPOSED ADDITION SF: -BASEMENT 280 SF -ATTIC SF 1117 SF PROPOSED TOTAL HOUSE SF 3797 SF DN DN Vent Hood DWREF Wa s h e r D FLOOR PLAN LEGEND: EXISTING WALL TO REMAIN PROPOSED NEW WALL NO WORK THIS AREA EXISTING DOOR NEW DOOR SP PHOTO SENSITIVE SMOKE DETECTOR (HARD WIRE) SCO COMBINATION PHOTO SENSITIVE SMOKE/CARBON MONOXIDE DETECTOR(HARD WIRE) HEAT DETECTOR (HARD WIRE)HT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. GENERAL CONSTRUCTION NOTES: USE METAL JOISTS AND BEAM HANGERS FOR ALL FLUSH FRAMED CONDITIONS, USE STEEL CONNECTION ASSEMBLIES TO FULLY DEVELOPE THE CONNECTED MEMBERS. ALL BEAMS AND LINTELS TO BE CONNECTED TO WOOD POSTS WITH MINIMUM 12 GA. STEEL POST CAPS BY "SIMPSON" OR EQUAL. THE MINIMUM INTERIOR HEADER SIZE IS 2 @ 2X6 TYPICAL, UNLESS NOTED OTHERWISE. (U.N.O) THE MINIMUM EXTERIOR HEADER SIZE IS 3 @ 2X8 TYPICAL, U.N.O. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED ALL STUD WALL DIMENSIONS ARE TO FACE OF STUD U.N.O. MASONRY/CONCRETE DIMENSIONS ARE TO FACE OF MASONRY/CONCRETE. CEILING HEIGHTS ARE SUBFLOOR TO UNDERSIDE OF FINISHED CEILING. ALL EXTERIOR STUDS ARE 5-1/2" U.N.O & ALL INTERIOR STUDS ARE 3-1/2" U.N.O. REFERT O STRUCTURAL DRAWINGS & SPECIFICATIONS FOR ADDITIONAL, STRUCTURAL, INFORMATION. CONTACT ARCHITECT WITH ANY FOUND DISCREPENCIES OR CONFLICTS. ALL DOORS AND CASED OPENINGS ARE TO BE LOCATED 5" FROM ADJACENT WALL FRAMING TO DOOR OPENING OR CENTERED ON THE WALL WHERE LOCATED, U.N.O. INTERIOR THRESHOLDS AT WOOD/TILE & WOOD/CARPET TRANSITION TO BE WOOD TO MATCH WOOD FLOORING. ALL CLOTHING CLOSETS TO HAVE A HANGING ROD AT 5'-6" AFF WITH EDGEBANDED PAINTED PLYWOOD SHELF ABOVE U.N.O. LINEN CLOSETS TO HAVE (5) 16" DEEP EDGEBANDED PAINTED PLYWOOD SHELVES ON LEDGERS, FINISHES WITHIN CLOSETS TO MATCH ADJACENT ROOMS. ALL WINDOW AND DOOR HEIGHTS TO MATCH U.N.O. (ALIGN FINISH HEAD TRIM, TYPICAL). A2.1 2 A2.1 1 A2.0 1 A2.02 156 SF GUEST BEDROOM 216 31 SF GUEST CLOSET-2 217 46 SF GUEST BATHROOM 218 55 SF BATHROOM 220 162 SF OFFICE 221 152 SF DINING 223 212 SF KITCHEN 224 177 SF LIVING ROOM 225 DECK DECK 3'-2"3'-2"2" 3' - 2 " 3' - 2 1 / 4 " OPEN STAIR 2ND FLOOR-ATTIC UP 10 1 / 2 " 9' - 7 1 / 4 " 3' - 1 1 " 11'-9" 5'-11 1/2" 22 ' - 1 0 1 / 2 " 3'-2" 5'-10" 16 ' - 7 3 / 4 " 5' - 8 " E E G-T E E E F JJEEC B A B I 43 SF PANTRY 246 23 SF STORAGE 247 A2.1 2 A2.1 1 A2.0 1 A2.02 108 SF BEDROOM-2 227 96 SF BEDROOM-3 228189 SF PRIMARY BEDROOM 229 43 SF HIS CLOSET 231 53 SF HER CLOSET 232 53 SF BATHROOM-2 233 93 SF LAUNDRY ROOM 235 58 SF MECHANICAL ROOM 236 18 SF CLOSET-2 237 13 SF CLOSET-3 238 6'-0"6'-0" 10'-1" 10 ' - 8 1 / 4 " ± 3' - 6 " 7'-8" ±8' - 1 0 " 10'-6" 8' - 3 3 / 4 " 2' - 0 " 6'-0"6'-0" DN 8' - 1 0 " 14 ' - 6 3 / 4 " 10'-6"4'-0" 6'-8"8'-3 1/2" K H-T H-T K KKKK D D D-T D-T 3'-6"3'-6" 4'-0" 1' - 6 " 1' - 6 " 3'-6" 3'-6". 2' - 7 " 53 SF PRIMARY BATHROOM 248 Scale Date 8/6/2025 6:56:33 PM 1/4" = 1'-0" A1.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PROPOSED 2ND & ATTICFLOOR PLAN 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 PROPOSED 2ND FLOOR 1/4" = 1'-0"2 PROPOSED 3RD FLOOR NOTE: EXISTING HOUSE SF: 2400 SF PROPOSED ADDITION SF: -BASEMENT 280 SF -ATTIC SF 1117 SF PROPOSED TOTAL HOUSE SF 3797 SF A2.1 2 A2.1 1 A2.0 1 A2.02 3 3 / 8 " / 1 ' - 0 " 9" / 1 ' - 0 " 9" / 1 ' - 0 " 9" / 1 ' - 0 " 9" / 1 ' - 0 " 3 3 / 8 " / 1 ' - 0 " 3 3 / 8 " / 1 ' - 0 " 3 3 / 8 " / 1 ' - 0 " 3 3 / 8 " / 1 ' - 0 " 3 3 / 8 " / 1 ' - 0 " FLOOR PLAN LEGEND: EXISTING WALL TO REMAIN PROPOSED NEW WALL NO WORK THIS AREA EXISTING DOOR NEW DOOR SP PHOTO SENSITIVE SMOKE DETECTOR (HARD WIRE) SCO COMBINATION PHOTO SENSITIVE SMOKE/CARBON MONOXIDE DETECTOR(HARD WIRE) HEAT DETECTOR (HARD WIRE)HT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. GENERAL CONSTRUCTION NOTES: USE METAL JOISTS AND BEAM HANGERS FOR ALL FLUSH FRAMED CONDITIONS, USE STEEL CONNECTION ASSEMBLIES TO FULLY DEVELOPE THE CONNECTED MEMBERS. ALL BEAMS AND LINTELS TO BE CONNECTED TO WOOD POSTS WITH MINIMUM 12 GA. STEEL POST CAPS BY "SIMPSON" OR EQUAL. THE MINIMUM INTERIOR HEADER SIZE IS 2 @ 2X6 TYPICAL, UNLESS NOTED OTHERWISE. (U.N.O) THE MINIMUM EXTERIOR HEADER SIZE IS 3 @ 2X8 TYPICAL, U.N.O. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED ALL STUD WALL DIMENSIONS ARE TO FACE OF STUD U.N.O. MASONRY/CONCRETE DIMENSIONS ARE TO FACE OF MASONRY/CONCRETE. CEILING HEIGHTS ARE SUBFLOOR TO UNDERSIDE OF FINISHED CEILING. ALL EXTERIOR STUDS ARE 5-1/2" U.N.O & ALL INTERIOR STUDS ARE 3-1/2" U.N.O. REFERT O STRUCTURAL DRAWINGS & SPECIFICATIONS FOR ADDITIONAL, STRUCTURAL, INFORMATION. CONTACT ARCHITECT WITH ANY FOUND DISCREPENCIES OR CONFLICTS. ALL DOORS AND CASED OPENINGS ARE TO BE LOCATED 5" FROM ADJACENT WALL FRAMING TO DOOR OPENING OR CENTERED ON THE WALL WHERE LOCATED, U.N.O. INTERIOR THRESHOLDS AT WOOD/TILE & WOOD/CARPET TRANSITION TO BE WOOD TO MATCH WOOD FLOORING. ALL CLOTHING CLOSETS TO HAVE A HANGING ROD AT 5'-6" AFF WITH EDGEBANDED PAINTED PLYWOOD SHELF ABOVE U.N.O. LINEN CLOSETS TO HAVE (5) 16" DEEP EDGEBANDED PAINTED PLYWOOD SHELVES ON LEDGERS, FINISHES WITHIN CLOSETS TO MATCH ADJACENT ROOMS. ALL WINDOW AND DOOR HEIGHTS TO MATCH U.N.O. (ALIGN FINISH HEAD TRIM, TYPICAL). Scale Date 8/6/2025 6:56:34 PM 1/4" = 1'-0" A1.2 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PROPOSED TOP OF ROOF 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"1 PROPOSED TOP OF THE ROOF NOTE: EXISTING HOUSE SF: 2400 SF PROPOSED ADDITION SF: -BASEMENT 280 SF -ATTIC SF 1117 SF PROPOSED TOTAL HOUSE SF 3797 SF EX. 1ST FLOOR 0' - 0" EX. 2ND FLOOR9' - 4" EX. ATTIC FLOOR18' - 4" EX. TOP OF ROOF29' - 8 7/8" EGRESS WINDOW EGRESS WINDOW THE SCOPE OF WORK EGRESS WINDOW EGRESS WINDOW C C E C J J JJ EEC K K K K L LLL B B 3'-6".3'-6" EX. 1ST FLOOR 0' - 0" EX. 2ND FLOOR9' - 4" EX. ATTIC FLOOR18' - 4" GROUND LEVEL-1' - 10" EX. TOP OF ROOF29' - 8 7/8" EGRESS WINDOW THE SCOPE OF WORK THE SCOPE OF WORK E E G-T E E EE G-T EE K H-T H-T K L L L L L 3'-6"3'-6". 1. 2. 3. 4. 5. 6. 7. 8. 9. ALL SILLS TO BE HISTORIC PROFILE: 2"+. EXTEND TO OUTSIDE OF CASING OR AS INDICATED ON DRAWINGS. ALL MULLIONS TO BE 7/8" SIMULATED DIVIDED LIGHTS WITH SHADOW BARS. ALL DOUBLE HUNG (CASEMENT AND AWNING TO HAVE FULL SCREENS) WITH HI TRANSPARENCY MESH. PROVIDE CORRECT JAMB EXTENSIONS AS REQUIRED FOR WALL THICKNESS. REFER TO EXTERIOR ELEVATIONS FOR MUNTIN LAYOUT. EXTERIOR JAMB TRIM TO BE 5/4" X 5" OR AS INDICATED ON DRAWINGS. ALL GLASS TO BE INSULATING, LOW E 368 WITH ARGON, TEMPER WHERE REQUIRED BY CODE. MODEL NUMBERS AND ROUGH OPENINGS ARE FOR (MANUFACTURER/SERIES) UNLESS OTHERWISE NOTED. HEAD R.O. INDICATED ON SCHEDULE UNLESS NOTED OTHERWISE ON DRAWINGS. SUBSTITUTE WINDOWS TO MEET ENERGY CODE AND MATCH MANUFACTURER ATTRIBUTES. MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECTURE REVIEW PRIOR TO ORDERING. GENERAL WINDOW NOTES: 1. 2. 3. 4. PROVIDE ALL NECESSARY STRUCTURAL BLOCKING AND RELATED WORK FOR DOOR, FRAME, AND HARDWARE INSTALLATION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. NO THROUGH-BOLTING WILL BE ACCEPTED. DOOR TO BE REINFORCED INTERNALLY. ALL DOORS SHALL BE NEW WOOD FINISH DOORS. THICKNESS TO BE 1-3/4" EXCEPT WHERE NOTED. MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECT REVIEW AND APPROVAL PRIOR TO ORDERING. GENERAL DOOR NOTES: WINDOW TYPES: A DOUBLE-HUNG B DOUBLE HUNGT.O. 1ST FLR SBFLR EL. 0'-0" 6' - 9 3 / 4 " R . O . T.O. 2ND FLR SBFLR EL. 0'-0" T.O. ATTIC FLR SBFLR EL. 0'-0" R.O WINDOW HEAD MEETS EGRESS REQUIREMENTS R.O WINDOW HEAD R.O WINDOW HEAD 1' - 8" 2' - 0 " 6' - 1 0 3 / 4 " R . O . MEETS EGRESS REQUIREMENTS C DOUBLE HUNG MEETS EGRESS REQUIREMENTS E DOUBLE HUNG MEETS EGRESS REQUIREMENTS J DOUBLE HUNG G DOUBLE HUNG A DOUBLE-HUNG B DOUBLE HUNG MEETS EGRESSREQUIREMENTS 1' - 8" 2' - 0 " MEETS EGRESSREQUIREMENTS C DOUBLE HUNG MEETS EGRESSREQUIREMENTS E DOUBLE HUNG MEETS EGRESSREQUIREMENTS F DOUBLE HUNG J DOUBLE HUNG G DOUBLE HUNG F DOUBLE HUNG I FIXED 5' - 9 1 / 4 " R . O . D DOUBLE HUNG MEETS EGRESS REQUIREMENTS K CASEMENT H CASEMENT 1/4" = 1'-0"1 PROPOSED FRONT ELEVATION Scale Date 8/6/2025 6:56:41 PM 1/4" = 1'-0" A2.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PROPOSED FRONT &REAR EXTERIORELEVATIONS 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"2 PROPOSED REAR ELEVATION WINDOW SCHEDULE WINDOW TYPE OPERATION R.O. DIMENSIONS MODEL COMMENTS CountWIDTHHEIGHT A 4' - 0"4' - 7 1/2"PARADIGM 2 B 2' - 6"4' - 7 1/2"PARADIGM 4 C 2' - 6 3/4"4' - 7 1/2"PARADIGM 4 D 2' - 4 1/4"4' - 2 3/4"PARADIGM 2 D-T 2' - 4 1/4"4' - 2 3/4"PARADIGM TEMPERED 2 E 2' - 9 1/2"4' - 7 1/2"PARADIGM 13 F 1' - 11"2' - 11 1/2"PARADIGM 2 G-T 2' - 0"3' - 3 3/4"PARADIGM TEMPERED 2 H-T 2' - 7"1' - 11 5/8"PARADIGM TEMPERED 2 I 2' - 5 1/2"2' - 4 1/4"PARADIGM 1 J 2' - 5 3/4"2' - 11 1/2"PARADIGM 4 K 2' - 7"3' - 9 5/8"PARADIGM 6 L 2' - 3 1/2"1' - 6"PARADIGM 9 EX. 1ST FLOOR0' - 0" EX. 2ND FLOOR9' - 4" EX. ATTIC FLOOR 18' - 4" EX. TOP OF ROOF29' - 8 7/8" THE SCOPE OF WORK A AB B DD I B B C 1'-6"1'-6" 1. 2. 3. 4. 5. 6. 7. 8. 9. ALL SILLS TO BE HISTORIC PROFILE: 2"+. EXTEND TO OUTSIDE OF CASING OR AS INDICATED ON DRAWINGS. ALL MULLIONS TO BE 7/8" SIMULATED DIVIDED LIGHTS WITH SHADOW BARS. ALL DOUBLE HUNG (CASEMENT AND AWNING TO HAVE FULL SCREENS) WITH HI TRANSPARENCY MESH. PROVIDE CORRECT JAMB EXTENSIONS AS REQUIRED FOR WALL THICKNESS. REFER TO EXTERIOR ELEVATIONS FOR MUNTIN LAYOUT. EXTERIOR JAMB TRIM TO BE 5/4" X 5" OR AS INDICATED ON DRAWINGS. ALL GLASS TO BE INSULATING, LOW E 368 WITH ARGON, TEMPER WHERE REQUIRED BY CODE. MODEL NUMBERS AND ROUGH OPENINGS ARE FOR (MANUFACTURER/SERIES) UNLESS OTHERWISE NOTED. HEAD R.O. INDICATED ON SCHEDULE UNLESS NOTED OTHERWISE ON DRAWINGS. SUBSTITUTE WINDOWS TO MEET ENERGY CODE AND MATCH MANUFACTURER ATTRIBUTES. MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECTURE REVIEW PRIOR TO ORDERING. GENERAL WINDOW NOTES: 1. 2. 3. 4. PROVIDE ALL NECESSARY STRUCTURAL BLOCKING AND RELATED WORK FOR DOOR, FRAME, AND HARDWARE INSTALLATION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS. NO THROUGH-BOLTING WILL BE ACCEPTED. DOOR TO BE REINFORCED INTERNALLY. ALL DOORS SHALL BE NEW WOOD FINISH DOORS. THICKNESS TO BE 1-3/4" EXCEPT WHERE NOTED. MANUFACTURERS TO PROVIDE SHOP DRAWINGS OF ALL PRODUCTS FOR ARCHITECT REVIEW AND APPROVAL PRIOR TO ORDERING. GENERAL DOOR NOTES: EX. 1ST FLOOR0' - 0" EX. 2ND FLOOR9' - 4" EX. ATTIC FLOOR 18' - 4" EX. TOP OF ROOF29' - 8 7/8" THE SCOPE OF WORK D-T D-T F E F C THE SCOPE OF WORK 1'-6" 1'-6"WINDOW TYPES: A DOUBLE-HUNG B DOUBLE HUNGT.O. 1ST FLR SBFLR EL. 0'-0" 6' - 9 3 / 4 " R . O . T.O. 2ND FLR SBFLR EL. 0'-0" T.O. ATTIC FLR SBFLR EL. 0'-0" R.O WINDOW HEAD MEETS EGRESS REQUIREMENTS R.O WINDOW HEAD R.O WINDOW HEAD 1' - 8" 2' - 0 " 6' - 1 0 3 / 4 " R . O . MEETS EGRESS REQUIREMENTS C DOUBLE HUNG MEETS EGRESS REQUIREMENTS E DOUBLE HUNG MEETS EGRESS REQUIREMENTS J DOUBLE HUNG G DOUBLE HUNG A DOUBLE-HUNG B DOUBLE HUNG MEETS EGRESSREQUIREMENTS 1' - 8" 2' - 0 " MEETS EGRESSREQUIREMENTS C DOUBLE HUNG MEETS EGRESSREQUIREMENTS E DOUBLE HUNG MEETS EGRESSREQUIREMENTS F DOUBLE HUNG J DOUBLE HUNG G DOUBLE HUNG F DOUBLE HUNG I FIXED 5' - 9 1 / 4 " R . O . D DOUBLE HUNG MEETS EGRESS REQUIREMENTS K CASEMENT H CASEMENT 1/4" = 1'-0"1 PROPOSED LEFT ELEVATION Scale Date 8/6/2025 6:56:46 PM 1/4" = 1'-0" A2.0 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PROPOSED FRONT &REAR EXTERIORELEVATIONS 07/10/2025 22 Prescott St, Salem, MA 01970 1/4" = 1'-0"2 PROPOSED RIGHT ELEVATION WINDOW SCHEDULE WINDOW TYPE OPERATION R.O. DIMENSIONS MODEL COMMENTS CountWIDTHHEIGHT A 4' - 0"4' - 7 1/2"PARADIGM 2 B 2' - 6"4' - 7 1/2"PARADIGM 4 C 2' - 6 3/4"4' - 7 1/2"PARADIGM 4 D 2' - 4 1/4"4' - 2 3/4"PARADIGM 2 D-T 2' - 4 1/4"4' - 2 3/4"PARADIGM TEMPERED 2 E 2' - 9 1/2"4' - 7 1/2"PARADIGM 13 F 1' - 11"2' - 11 1/2"PARADIGM 2 G-T 2' - 0"3' - 3 3/4"PARADIGM TEMPERED 2 H-T 2' - 7"1' - 11 5/8"PARADIGM TEMPERED 2 I 2' - 5 1/2"2' - 4 1/4"PARADIGM 1 J 2' - 5 3/4"2' - 11 1/2"PARADIGM 4 K 2' - 7"3' - 9 5/8"PARADIGM 6 L 2' - 3 1/2"1' - 6"PARADIGM 9 2 FRONT-LEFT PERSPECTIVE VIEW 1 REAR-RIGHT PERSPECTIVE VIEW Scale Date 8/6/2025 6:56:59 PM A3.0 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PERSPECTIVE VIEWS 07/10/2025 22 Prescott St, Salem, MA 01970 Scale Date 8/6/2025 6:57:15 PM A3.1 EXISTING CONDITION 07/10/2025 PROP. NEW DORMERS& INT.RENOVATION SCOPE: PROP. NEW DORMERS & INT. RENOVATION PERSPECTIVE VIEWS 07/10/2025 22 Prescott St, Salem, MA 01970 1 FRONT-RIGHT PERSPECTIVE VIEW 2 REAR-LEFT PERSPECTIVE VIEW