Loading...
392 ESSEX STREET - BUILDING JACKET 392 ESSEX STREET ol I. Lu -c lip -i JON T. SKERRY ATTORNEY AND COUNSELLOR AT LAW Six LYNDE STREET SALEM, MASSACHUSETTS 01970 (978)745-9481 Fax: (978)741-8354 (978)745-9488 February 20, 2002 Peter Strout Building Commissioner Building Department 120 Washington Street Salem, MA 01970 Re: 392 Essex Street Dear Mr. Strout: Thank you for taking the time to meet with me last week. As you know, I represent Mr. and Mrs. James Bailey relating to litigation concerning a fire at 392 Essex Street. Shortly after the fire, an investigator for Mr. and Mrs. Bailey's insurer reviewed your filed and made copies of documents in your file. Enclosed is a letter dated March 3, 1994 and signed by Mr. Leo E. Tremblay, Inspector of Buildings. When I reviewed your file, this letter from Mr. Tremblay was not in the file. When your schedule permits, I request that you telephone me so that we can discuss the March 1994 letter. I thank you for your anticipated cooperation. *nT. rry JTS/hn Enclosure DATE OF PERMIT PERMIT O NER LOCATION_�i CV'/ / l HIS i la GIS 1 �IC f Df Fav E� OO//CC1l 11/22/74 I #339 Allyn Rea ty Tru 392 Essex Street STRUCTURE MATERIAL DIMENSIONS No.OF STORIES I No.OF FAMILIES I WARD I COST 3 BUILDER Demolish building. LAWFUL THREE FAMILY AS PER ZONING ENFORCEMENT OFFICE: LEO E. TREMBLAY 2/09/99 1161-99 DEMOLITION & CLEAN-UP OF BURNT DEBRIS FROM FIRE.est. 8,000.00 fee 53.00 RGG 5/25/99 11351-99 REBUILD 3RD FLOOR & ROOF STRUCTURE. FIRE DAMAGE. OUTSIDE ENVELOPE ONLY. PC P(AA5 5u6rn l e6 . e54. X5" 000 -Pe 10/06/99 #698-99 2ND PERMIT FOR ADDITIONAL RECONSTRUCTION FROM FIRE DAMAGE. PLANS SUBMITTED. est. 175,p000.00 fee 1750.00 T.J.S. L0r11Yacto/ 1✓ GV�l�(/^j 3Z�o^ �lajPcf J�(�/coq �(� 8/31/00 1698-99 TEMPORARY OF CERTIFICAT OF OCCUPANCY FOR UNIT #5 ONLY. 30 DAYS. 8/31/00 - 9/30/00. F.R.D. 9/29/00 #698-99 CERTIFICATE OF OCCUPANCY ISSUED ON ALL UN T (16). 30 FEE T.J.S. I i DATE OF PERMIT PERMIT o OWNER 1 LOCATION C�/ 15I K!G blSi iL' ! r'r+'UF'� �1 Js- 11/22/'74 #339 Allyn Realty Tust T `392 Essex Street STRUCTURE MATERIAL DIMENSIONS No. OF STORIES No.OF FAMILIES I WARD Coll 3 BUILDER Demolish building. LAWFUL THREE FAMILY AS PER ZONING ENFORCEMENT OFFICE: LEO E. TREMBLAY L d; A/ INSPECTION REPORT DATE: 7 � d 7's •� --y,_� err ADDRESS : i OWNER: G'/L'�' 19trp,/�/ USE GROUP : NUMBER OF STORIES : G� NUMBER OF ROOMS »(By . STORY) : HOW HEATED: 7// ems/✓fid j� � GAS: YES . V NO: NUMBER OF SANITARIES ! SCJ NUMBER OF ,APPROVED EGRESS DOORWAYS : _ REMARKS: _���i/i�d�' ��•�-,/Fear �-/Cj d .�.1',�rre. 6i �:+ �o~;✓ S� (situ of i$ttlrm' massar4usrtts 3 �a Public Prn}terig 13epnriment iguilbing Ervartment (One #attm Green 588-745-9595 Ext. 388 Leo E. Tremblay Director of Public Property Inspector of Building Zoning Enforcement Officer March 3, 1994 James Bailey 81 Essex Street Salem, Mass. 01970 RE: 392 Essex Street Dear Mr. Bailey: I sent you a letter on February 15, 1994 referring to a complaint received alleging that the third floor apartment at 392 Essex Street has only one means of egress. On Tuesday March I , 1994 I meet with you at 392 Essex Street and my inspection of the property finds that two means of egress do exist, and are Legal grandfathered means of egress. Thank you for your cooperation in this matter. Sincerely, Leo E. Tremblay Inspector of Bui dings LET: scm cc: Councillor Kevin Harvey Q 1 DATE OF PERMIT PERMIT!��p ` O NE,R ++ 'i392�Esse ATIONri 11/22/74 #339 15 Allyn Real y� 7Y'ILL x Street -Z I STRUCTURE MATERIAL DIMENSIONS No.OF STORIES I No.OF FAMILIES I WARD I COST i 3 BUILDER Demolish building. LAWFUL THREE FAMILY AS PER ZONING ENFORCEMENT OFFICE: LEO E. TREMBLAY 2/09/99 1161-99 DEMOLITION & CLEAN-UP OF BURNT DEBRIS FROM FIRE.est. 8,000.00 fee 53.00 KGG 5/25/99 11351-99 REBUILD 3RD FLOOR & ROOF STRUCTURE. -FIRE DAMAGE. OUTSIDE ENVELOPE ONLY. rl!k PeE pb)�5 '5ujrAk4e6 . e51. '�57_1000 -W fe kSSOD ?S5 L 10/06/99 #698-99 2ND PERMIT FOR ADDITIONAL RECONSTRUCTION FROM FIRE DAMAGE. PLANS SUBMITTED. est. 175,000 00 fee +1750.00 T.J.S. (,On f/cr�,tor GJ f�i�ibr�.t/�^5 . o-^. Ajt'cf - i 8/31/00 #698-99 TEMPORARY OF CERTIFICAT OF OCCUPANCY FOR UNIT #5 ONLY. 30 DAYS. 8/31/00 - 9/30/00. F.B.D. 9/29/00 #698-99 CERTIFICATE OF OCCUPANCY ISSUED ON ALL 1 T . (16). 30 fOf FEE T.J.S. i s II r 'i ' '•.It , I n 'I 1 I, �.; t 1 ..1 1 'u � I� L1 � r,.I. = 1 1 ..I; 1 rl �� 1.x'1 I•S Date r MY. Town City of Building,inapectorIlk,i* Massachusett II IV Dear Sirs I In accordance with Section 111,43 and Section 120.3 of (� the State Building Code, I, as the owner, ereby request an inspection of the premises at and the issuance of a Use and Occupancy Certifi ate. IIS Entry to• theISI premises may be obtained by contacting • IIT, R. W. Carlson Assoc. , .Inc. should you determine that an inspection is necessary or desired. is Will y YOU kindly acknowledge that you have received this it letter by signing and dating the attached co it to me in the .enclosed envelope.. copy, and returning Yours very='truly, 1 ,Ii I i Owner , IIL On 19 , I received this letter for the issuance of a Use and Occupancy Certificate. I� li l QAn inspection will be made by a= r F .I. 1' office witbi t1Lee dads. An inspection will not be made by our office. ,• I " Building inspector l P I 392 Essex Street I L-1 I 75 NAME OR ADDRESS I JAN I FEGIMAJ APRI MANJ JUN JUL OCNO AU SEP V OE USE I YEAR PURPOSE USED PROVIDE THE FOLLOWING INFORMATION AS APPLICABLE # OF STORIES 3,9,R CLASS OF CONSTRUCTION DATE ERECTED CERTIFIED CAPACITY: (BY STORY OR TYPE) NUMBER OF ROOMS - HOSPITALS, SCHOOLS. HOTELS: (BY STORY OR TYPE) 1s1- ant. l - lrm. &. R 2- 2 rms . & R 3- 2 rms. &R 13- 2 rms . & B 14- 2 rms . & B 15-_3 rms . & a B 16- 2 rms & B 2nd- apt 4- 2 rms & B 5- 2 rms R• hath _ 6- 2 rms _ P. R 7- ?rms. & R 17- 2 rms . & R Is- 3 rms. & R 3rd- ant . A- 2 rms. R•. R 9- 2 rms. & R. 10- 2 rms'. & R 11 - 2 rms . & R 12- 2 rms. & R NUMBER OF DWELLING UNITS PER STORY 7 q_ Game as above 0 FORM SBCC-2.74 • EMERGENCY LIGHTING SYSTEM MEANS OF DETECTING AND EXTINGUISHING FIRE If OF ELEVATORS HOW HEATED Steam by oil - BOILER fl _BOILER OR OTHER HEATING APPARATUS HOW LIGHTED HOW VENTILATED PLACE OF ASSEMBLY: YES NO PURPOSE USED IN WHICH STORY STANDARD BOOTH INSTALLED LOCATION FIXED SEATING # OF AISLES AND WIDTH FIRE RESISTANCE OF CURTAINS OR DRAPERIES # OF SANITARIES 20 LOCATION # OF GRADE FLOOR MEANS OF EGRESS DOORWAYS 6 # OF SEPARATE STAIRWAYS ACCESSIBLE PER STORY # OF APPROVED INDEPENDENT EXITWAYS PER STORY CERTIFICATE DATA EXPIRES ISSUED CERTIFICATE NO. INSPECTOR 1980 ... ORDERS N..,, . .,,. ,y• ISSUED COMPLIED ISSUED COMPLIED 19 19 19 19 19 19 19 19 19 19 19 19 REMARKS 111 . 43 120. 3 - cert . to - Allyn Realty 210 STREET 8 NUMBER 392 Essex Street DATE 5/19 OTHER LICENSES OR PERMITS REQUIRED OWNER OF RECORD OF BUILDING ADDRESS CERTIFICATE ISSUED TO ADDRESS NAME OR ADDRESS IJAN IF.EBIAARVPRHAYPUN [JUL UG EPCT NOV I'EC USE YEAR L 392 Essex Street VY(Irl) �i�,i ��� N L-1 7 r • f i 4 �`�'➢"``°�t Oli#g of Salem, H�ssttcl�usQ##s Fublir PropertU Department Puilbins P' yartment I Sohn �. �'3o[ners 5 �irnnD �irret 745-0213 Dear Sir: We are in receipt of your request of April 18,1975 for an inspection at' ' 392 Essex Street Salem, M. Upon payment of a fee of $ 25 nn , this office will make the requested inspe-ption. l �� �J.. .`� G�c✓l,a.S Inspector of Buildings rr s SALEM HEALTH CEPARTMENT 9i 9 North Street , _ Salem, MA 01970 VIOLATIONS 392 ESSEX STREET CONSTRUCTION MATERIAL PLACED OUT FOR MUNICIPAL COLLECTION MUST BE REMOVED AND BROUGHT TO AN APPROVED SITE-(FOREST STREET IN PEABODY FOR ONE) AND THE AREA CLEANED AND MAINTAINIED. fINSPECTION REPORT DATE: ADDRESS: ���aar OWNER: 1091111,14-'7yy11lf/t.i /`r+ •��� �� 5 R�AT"`S' . i USE GROUP: NUMBER OF STORIES: 30" w NUMBER OF ROOMS (BY STORY) : HOW HEATED: ,15;l Ae g 0 O GAS: YES . NO: NUMBER OF SANITARIES: s2�J NUMBER OF .APPROVED EGRESS DOORWAYS: REMARKS: FEE RECEIVED: YES 21 . v NO: Page 1 of SALEM HEALTH DEPARTMENT 9 North Street Salem,MA 01970 4JA State Sanitary Code,.Gfapter 11 105.CMR 410.000 Minimum Standards:of Fdriess'for'Human Habitation t } v.�r:•.d n JY tint' Occupant SIA94 A1_btd{� Phone.—wise - r . l} .i' H.`. 7`£,qy > . Aa7r Address9,2. c• ctr �S j- Apt. —fiI, + Floor r r Owner zgm_eS A eU-d1x2._ P. 6aa.E7 Address: Inspection Date ? -H qg TmO.a f ,:'.- `�su`� Conducted By:4Y.&I,e-Fa k/,c Accompand ieey: _ -Accompanied . .... Anftcipated 'y' Reinspection Date. - Specified :Reg#t.io: ..'a•Molation ?rrbAss. .r. =c f Time 410. . . . .., : a , rt z.:.:• r i i;e;.:, uill, }3: .-a s � 5 a s' 41'J�V4 16-040 o p e Dive' p N ..X ::i•>` i L. ] a^.n 3J E. 4..ai{..4 - ta._.... r...._..:.'..IIJ 3.. _.aR . ...:,.,. t,.... .i.. . P: .. ,. t. 7� ' r { :±� "L t .r ":x9. . ..:(I.i'7nt'I,17-,s: >a. 1.'' .. .J'✓. i.. .. r Al Ce e N N v s One or more of the above violations may endanger or materially impair the health, safety and well-being dor-tth�ee occupants(s) — JAL'( zz�. /_e J Code Enforcement Inspector Este es un documento legal imponanle. Puede que afecte sus derechos. Puede adquinruna lraduccion de esta forma. j •w y t 5 ' � d..f:='.�. l rte. �_:^..Aa,'a•4`. 3�3l.. 2�"li rr� Y . •: ire Af.: vv.1'a'f It'lwi UJ t D,Ftil .i, s`c: .,,. APPENDIX Legal Remedies for Tenants of Residential Housing The following Is a brief summary of some of the legal remedies tenants may use In order to get hottsing code violations corrected:-- c:#; .t•14 - - --- -. . .. 1..Rent Withholding(Massachusetts General laws;Chapter 239,section 8A): U Code Violations Are Not Being Corrected you may be entitled to hold back your rent payments.You can do this without being evicted if: A. You can prove that your dwelling unit or common areas contain code violations which are serious enough to endanger or materially impair your health or safety and that your landlord knew about the violations before you were behind in= your rent. Bw Yoodid notcause the viohutions'and they pn be repaired while you continue"to live in the building.- C. inldtng:C. You are prepared to pay any portion of the rent tiito court if a judge orders you to pay it.(For this,it is best to put the, rent money aside in a safe place.)- _� ,�. .. 2. RW it and a d Deduct(Massachusetts General laws,Chapter 111,section 127L):The law sometimes allows you to use your rent money to make the repairs yourself.if your local code enforcement agency certifies that there are code violation s.which endanger or materially impair your health,safety,or welt-being,and your landlord has received written notice of the violations;; _you maybe able_to use this_mmedy.-lf the-owcerrfails to,begin.necessarmepairs(or to enter into a written contract to have the>ih. made).within five days after notice or to complete,repairs within 14 days after notice, you can use up to four months rent in:anf; year to ma -the repairs. 3. Retaliatory Rent Increases or Evictions Prohibited(Massachusetts General Laws,Chapter 186,section 18,and Chapter 239„ section 2A)' e owner may not yourrent or evicfyou in etalrayon for making p a comlainr Ttito your local code enforcement agency.aboutcode.yrolanons;X the owner-.raises your rent to triesto.evict within srz.months after you have made the complaint,be or she -showa good reason for the increase or eviction which is.unrelated to your complaint..You maybe able-to sue-the-landlord for y damages'oPhe or she tnes'this�_ .3` i SN 3. 4' �, ��+t.. "3 C'.l .♦ Vit'\=r R, "Y . f i .. 4. ReniReni Receivership(Massachusetts General Laws,Chapter'I1, section 127 GH) The occupants and/or the Board of Health may petition the DistricCor Superior Court to allow rent to be paid into court rathei'than'to the owner:The total my then appoint a receiver"who may spend as much of the rent money as is,needed to correct the violation.The receiver is not subject 16 a spending limitation of four months'rent 5. Breach of Warranty of Hnbitability. You may be entitled to sue your.landlord to have all or some of your rent returned if your.: dwelling unit does not meet minimum standards of habitability. 6. Unfair and Deceptive Practices(Massachusetts General Laws,Chapter 93A): Renting an apartment with code violations is a violation of the consumer protection act and regulations, for which you may sue an owner. The information presented above is only a summary of the law.Before you decide to withhold your rent or take any other legal action, it is advisable that you consult an attorney. If you cannot afford to consult an attorney, you should contact the nearest legal services office, which is: Neighborhood Legal Services 37 Friend St. Lynn, MA 01902 (617) 599-7730 IIr I •• r ,fir � /I � � . • r , t I/ ' / / "/ i Mm lffM oop .(/ _ _i ' ' / _v / '. 1 r r ' tea• i If WWI _ / I / 6 • I e .• : / .ii ilii .' ., � i//:d -® �r I ' ' • i ui � iii �e , --�.� • � .moi --, --- Vaga Q.1 SALEM HEALTH DEPARTMENT ��iDate 9 tJorth Street — 8alem,.MA 01970 Name : Address: Address: Specified Reg # Violation Time ...} .. rte. �. , ,h S1:'? COPY ' ° BUILDING CITY OF SALEM P SALEM, MASSACHUSETTS 01970 PERMIT DATE `IL' I('-'I'"I� 4.i1" 19 J,j :PERMIT NO. S9i—:L 9" 9 - - "n "Iu =" f-iR0..'cLLA S'I' RI:::E'i 1=i6 APPLICANT til-:=Ott bt. I . i- ,.14. ADDRESS '-" (NO.) (STREET) (CONTR'S LICENSE) 193 7 a 44b CITY SALE STATE_ZIPCODE -- TEL.NO. rc - ; ik MIDRE rfIlYli NUMBEROF "I FC 1R M _,aCi.a i..h.i J �DWELLINGUNITS_ .PERMITTO (_) STORY (TYPEOFIMPROVEMENTI NO. (PROPOSED USE) ZONING I_�_ AT(LOCATION) L""3`' F""''�L'^ "I REE: DISTRICT (NO.) (STREET) BETWEEN (CROSSSTREET) _ AND (CROSS STREET) LOT BLOCK LOT III�i%i 7C'.ShlTI SG! F? SUBDIVISION IZQS-• BUILDING IS TO BE FT.WIDE BY FT.LONG BY FT.IN HEIGHT AND SHALL CONFORM IN CONSTRUCTION TO TYPE USE GROUP BASEMENT WALLS OR FOUNDATION (TYPE) REMARKS: c�.ID !='_FAY !-D R, i!=1D:J1i 1.CD N, i>._ ct_:0'.i-i r,UE 1.0:! rtui'=I F'i.F:c LFI€;AC:':1E. r'!._i�€`:IS 3i1F� ;yl1 T'"(�F; ^' 4 AREA OR ` . Gall o 9 e l ilt tV Occupy 7 :]. 'l.:Idil1 FEPERMIT � 7�7:�yl. llU VOLUME ESTIMATED COST y. ) (CUBIC/ EFEET) Fi:. Y ..,. Cf Fs OWNER BUILDING DEPT. _ J. "'i.. ADDRESS l31 �" BY THIS PERMITCONVEV$NC fT0 ANY STREET,ALLEY OR SIDEWALK OR ANYPART THE9EOF.,EITHER TEMPORARILY OR PERMANENTLY ENCROACHMENTS. ►.ON.PUBLK:,PROPER NC.. . :ir IFICALL. . . RMITTED UNDER THEEBUILDING CODE.MUS.T'BE'"APPROVED BY THE JURISDICTION,STREET OR ALLEY GRADES AS WELL AS DEPTH AND LOCA F PUBLIC SEWERS MAY BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE APPLICANT FROM TH O DI►IONS OF ANY APPLICABLE SUBDIVISION RESTRICTIONS. MINIMUMOFTHREEC U-fSPECTIONS APPROVED PLANS MUST BE RETAINED ON JOB AND THIS CARD KEPT WHERE APPLICABLE SEPARATE REQUIRED FOR ALLC NS RU(#ION WORK: POSTED UNTIL FINAL INSPECTION HAS BEEN MADE. WHERE A PERMITS ARE REQUIRED FOR 1.FOUNDATIONS OR FOOTINGS. ELECTRICAL,PLUMBING AND 2.PRIOR AT Cto! STRUCTURAL CERTIFICATE OF OCCUPANCY IS REQUIRED,SUCH BUILDING SHALL MECHANICAL INSTALLATIONS. MEMBERS LATH). ++ NOT BE OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE. 3.FINAL INSPFORE OCCUPANL`Y. � THIS CARD SO IT IS VISIBLE FROM STREET BUILDING INSPECTION APP OVALS PLUMBING INSPECTI APPROVALS ELECTRICAL INSPECTION APPROVALS ,QczF"kSti Cly �ll?iC� P o0 eIr C ,p BOARD OF HEAL H GAS IN PECTI�OpN/APPROVALS - FFIRE EPT.INS NG APPROVALS /PELTI Cl C` �` 7 X �v OTHER ENGINEER - 2 ' '� 2 WORK SHALL NOT PROCEED UNTIL THE FAS IT WILL BECOME NULL AND VOID IF CONSTRUCTION WORK IS INSPECTIONS INDICATED ON THIS CARD INSPECTOR HAS APPROVED THE VARIOUS STARTED WITHIN SIX MONTHS OF DATE THE PERMIT IS ISSUED CAN BE ARRANGED FOR BY TELEPHONE OR WRITTEN NOTIFICATION. STAGES OF CONSTRUCTION. ' OTED ABOVE. Commonwealth of Massachusetts ILN,coNmT��s City of Salem 'IV a 120 Washington St,3rd Floor Salem,MA 01970(978)745-9595 x5641 ° R PERMIT REPORT BY ADDRESS AddreSS: 392 ESSEX STREET PIN Permit For Parcel ID Occupancy Type Building Type Work Description Construct. Fee Paid Cost G-2001-0055 25-0099 Residential Multifamily 3+ Basement-1 heating boiler,2 0 38 dryers G-2003-0192 434 Residential:additions,alterations,conv. 25-0099 Residential Multifamily 3+ G118-2003 15 NEW HEATING 0 470 BOILERS APTS.1-16 REQ.BY KEN CARPULC Total Permits: 2 0 508 loft UAie Ur FtM11 11 � w•.••,,••,• r/I/// 11 22 74 , I #339 'All Rea t I3'r'uR p Yn a Y sLo" 392aEssex Street -� STRUCTURE MATERIAL DIMENSIONS No.OF STORIES I No.OF FAMILIES WARD COST 3 BUILDER k ` Demolish building. LAWFUL THREE FAMILY AS PER ZONING ENFORCEMENT OFFICE: LEO E. TREMBLAY 2/09/99 #61-99 DEMOLITION & CLEAN-UP OF BURNT DEBRIS FROM FIRE.est. 8,000.00 fee 53.00 KGC 5/25/99 #351-99 REBUILD 3RD FLOOR & ROOF STRUCTURE. FIRE DAMAGE. OUTSIDE ENVELOPE ONLY. `ER PC P/AA5 SubrAlhedd • 0>4- '�r000 .0u S-ss_-00 -rS- -5 . 10/06/99 #698-99 2ND PERMIT FOR.ADDITIONAL RECONSTRUCTION FROM FIRE DAMAGE. PLANS SUBMITTED. est. 175,000.00 fee 1750.00 T.J.S. Confyactor 4/;11'/0 wt/%-5 /01'ajecf r_ 8/31/00 8698-99 TEMPORARY OF CERTIFICAT OF OCCUPANCY FOR UNIT #5 ONLY. 30 DAYS. 8/31/00 - 9/30/00. F.R.D. " 9/29/00 #698-99 CERTIFICATE OF OCCUPANCY ISSUED ON ALL T . (16). 30 FEE T.J.S. 3 CITY OF SALEM BOARD OF HEALTH Salem, Massachusetts 01970-3928 JOANNE SCOTT, MPH, RS,CHO NINE NORTH STREE- HEALTH AGENT February 5, 1998 Tel:(M)741-1800 Fax:(978)740-9705 James A. &Claire P. Bailey 81 Essex Street Salem, MA. 01970 Dear Sir/Madam : In accordance with Chapter III, Sections 127A and 127E of the Massachusetts General Laws, 105 CMR 400.00; State Sanitary Code, Chapter I: General Administrative Procedures and 105 CMR 410.00: State Sanitary Code, Chapter Il: Minimum Standards of Fitness for Human Habitation, an inspection was conducted of the property located at 392 Essex Street Apt.#14 occupied by Susan Hatch conducted by Virginia Moustakis,Senior Sanitarian, on Wednesday, February 4, 1998 at 12:15 P.M.. Notice: If this rental unit is occupied by a child or children under the age of 6 years, it is the property owner's responsibility to ensure that this unit complies fully with 105 CMR 460.000: Regulations for Lead Poisoning Prevention and Con{rol. For further information or to request an inspection, contact the Salem Health Department at 741-1800. You are hereby ORDERED to make a good-faith effort to correct the violations listed on the enclosed inspection report. Failure on your part to comply within the time specified on the enclosed inspection report will result in a complaint being sought against you in Salem District Court. Time for compliance begins with receipt of this Order. Should you be aggrieved by this Order, you have the right to request a hearing before the Board of Health. A request for said hearing must be received in writing in the office of the Board of Health within 7 days of receipt of this Order. At said hearing, you will be given an opportunity to be heard and to present witness and documentary evidence as to why this Order should be modified or withdrawn. You may be represented by an attorney. Please also be informed that you have the right to inspect and obtain copies of all relevant inspection or investigation reports, orders and other documentary information in the possession of this Board, and that any adverse party has the right to be present at the hearing. Please be advised that the conditions noted may enable the occupant(s)to use one or more of the statutory remedies available to them as outlined in the enclosed inspection report form. For4he Board of H/ea the Reply to: •r—tit �oanne Scott Virginia Moustakis Health Agent Senior Sanitarian cc: Tenant, Fire Prevention, Building Department,/Electrical Department, & Councillor Reginna Flynn-_, — _ Certified Mail#Z 279 292 673 JS/sjkun a '�>rnwa CITY OF SALEM BOARD OF HEALTH Salem, Massachusetts 01970-3928 JOANNE SCOTT. MPH, RS, CHO NINE NORTH STREE 1 HEALTH AGENT Tel:(978)741-1800 February 19, 1998 Fax.(978)740-9705 James A. & Claire Bailey l�VV 81 Essex Street Salem, MA. 01970 Dear Sir / Madam : In accordance with Chapter II of the State Sanitary Code, 105 CMR 410.000, Minimum Standards of Fitness for Human Habitation, a recent reinspection was conducted of your property located at 392 Essex Street Apt.#14 by Virginia Moustakis, Senior Sanitarian of the Salem Health Department on Thursday, February 19, 1998. The violations noted in the report of February 5, 1998 have been corrected. Thank you for your cooperation in this matter. For the Board of Health : Reply to: 'Joanne Scott Virginia Moustakis Health Agent Senior Sanitarian cc: Tenant, Fire Prevention,'Building Dept,,: Electrical Dept., & Councillor-R. Flynn--- J lynnJ S/sj k ahmn CITY OF SALEM BOARD OF HEALTH Salem, Massachusetts 01970-3928 JOANNE SCOTT, MPH, RS,CHO NINE NORTH STREET HEALTH AGENT February 5, 1998 Tel:(978)741-1800 Fax:(978)740-9705 James A. &Claire P. Bailey 81 Essex Street Salem, MA. 01970 Dear Sir/Madam : In accordance with Chapter III, Sections 127A and 127B of the Massachusetts General Laws, 105 CMR 400.00; State Sanitary Code, Chapter 1: General Administrative Procedures and 105 CMR 410.00: State Sanitary Code, Chapter 11: Minimum Standards of Fitness for Human Habitation, an inspection was conducted of the property located at 392 Essex Street Apt.#14 occupied by Susan Hatch conducted by Virginia Moustakis, Senior Sanitarian, on Wednesday, February 4, 1998 at 12:15 P.M.. Notice: If this rental unit is occupied by a child or children under the age of 6 years, it is the property owner's responsibility to ensure that this unit complies fully with 105 CMR 460.000: Regulations for Lead Poisoning Prevention and Control. For further information or to request an inspection, contact the Salem Health Department at 741-1800. You are hereby ORDERED to make a goad-faith effort to correct the violations listed on the enclosed inspection report. Failure on your part to comply within the time specified on the enclosed inspection report will result in a complaint being sought against you in Salem District Court. Time for compliance begins with receipt of this Order. Should you be aggrieved by this Ober, you have the right to request a hearing before the Board of Health. A request for said hearing must be received in writing in the office of the Board of Health within 7 days of receipt of this Order. At said hearing,you will be given an opportunity to be heard and to present witness and documentary evidence as to why this Order should be modified or withdrawn. You may be represented by an attorney. Please also be informed that you have the right to inspect and obtain copies of all relevant inspection or investigation reports, orders and other documentary information in the possession of this Board, and that any adverse party has the right to be present at the hearing. Please be advised that the conditions noted may enable the occupant(s)to use one or more of the statutory remedies available to them as outlined in the enclosed inspection report forth. Fo he Board of Heath: Reply to: oanne Scott Virginia Moustakis Health Agent Senior Sanitarian cc: Tenant, Fire Preventio,n, Building Department, lectricai Department, & Councillor Reginna Flynn Certified Mail#Z 279 292 673 JS/sjk F„mwoLt sJ . I . Date Mr. Town City of Building Inspector Massachusett Dear Sir, i In accordance with Section 111.43 and Section '120.3 of the State Building Code, inspection of the I' -as the owner, ter request an and premises at � G ' the issuance a uance /� . . o f a ,U:s a �.L..� 6 /1- and Occupancy Certifi ate. Entry to- the premises may be obtained by R, W. Carlson-Assoc, , Inc. should you contacting u determine that an inspection is necessary or desired. Will you kindly acknowledge that YOU h letter by signing and dating the attached cove received this it to me in the ,enalosed envelope.. PY, and returning Yours very truly, Owner �� On issuance of a Use and Occupancy,Certificate. ,received letter. for the Qan inspection will be made b•rfiice with u .three An inspection will not be made by our office, i . I• " Building Inspector 1 n. •�t � 1 '', 11 � jl � I 1 I I. IIjj i I jl ltll 1 ' I . Date j Tow ity of T , Building Inspector ' I, Ton C Massachusett I � Dear Sirs li In accordance with Section 111.43 and Section 120.3 of the State Building Code, I, as the owner, ereby request an II inspection of the premises at and the issuance of a Use and Occupancy Certif' ate. Entry to- the premises may be obtained by contacting R. W. Carlson Assoc. , .Inc. should you determine that an inspection is necessary or desired. Will you kindly acknowledge that you have received this �Illlj letter by signing and dating the attached copy, and returning II it tome in the .enalosed envelope.• ; I 1 Ili Yours veryltruly, CZ Owner ��llI i On 19 I received this letterfor the II ' issuance of a Use and Occupancy Certificate. ' Ili 3n inspection will be made by c= office within, three dads. An inspection will not be made by our office. I It l l: I Building Inspector • I II; 1 {i ' f ( 1. I 1 4 \ .\! "` �1 i•' 1 ,3 , ` � 1/tI� 1 �!1 r ,- 1'• 11 , I Date 1j Mr . Building Inspector 'I sown City of I� Massachusett (2�� . 1 , z IJ Dear Sir: it In accordance with Section 111.43 and Section 120.3 of the State Building Code, I, ae the owner, ereby request an inspection of the premises at 192 and the issuance of a Use'and Occupancy Certifi ate. �II 1 Entry to• the, premises may be obtained by contacting R. W. Carlson Assoc. , .Inc. should you determine that an 1 inspection is necessary or desired. !I� Will you kindly acknowledge that you have received this letter by signing and dating the attached copy, and returning it to no in the .enclosed envelope., Yours very ,truly, CILciL1 )u;1�� Owner on 19 , I received this letterfor the issuance of a Use and Occupancy Certificate. ' Qan inspection will be mace by c= o_tice witb .n ,ta=ee cais, An inspection will not be made by our office. Building Inspector r I r X1.1 1 i Date Mr. Town City of Building Inspector ; i Mass acchuus�ett Res_ . • ��� r , Dear sii In accordance with Section 111,43 and Section 120,3 of the State Building Code, I, as the owner inspection of the premises at ereby request an.; and the issuance of a Use and Occu anc ,_ p y erti£i�ate, y7 � Entry to-the R• W, Carlson Assoc. # Inc. maybe obtained by contacting .Inc inspection is nedshould you determine that an essarII y or desired. Will you kindly acknowled a that letter by signingand datingthe attached coYou ve received this it to me in the .enolosed envelope, 'I , pY. and returning Yours very,. L! I , 'truly,`- 1 1 Owner i Onreceived 19 issuance of a Use and Occupancy,Certificate, hie letter. for the �II Q An inspection will be made by arr office within three des, An inspection will not be made by our office, 1 I � i Building Inspector scowl CITY OF SALEM9 MASSACHUSETTS BOARD OF APPEAL 120 WASHINGTON STREET, 3RD FLOOR SALEM, MA 01970 TEL. (978) 745-9595 FAX (978) 740-9846 STANLEY J. USOVICZ, JR. MAYOR July 2, 2002 Paul E. Mitchell Mitchell 6 DeSimone 99 Summer- Street Boston, MA. 02110 Dear Mr. Mitchell: Attached is the file on 392 Essex Street as requested. Sincerely, Marcia Kirkpatrick Attached: file COMMONWEALTH OF MASSACHUSETTS ESSEX, SS SUPERIOR COURT C. A. NO: 02-0095 Dorothy Diane Linehan, by and ) through her executor, Shawn ) Beaupre ) Plaintiff, ) V. ) James A. Bailey, Claire P. Bailey, ) And Doug Young, ) Defendant. ) DEPOSITION SUBPOENA TO: Keeper of the Records m Building Department Attest : A i :lle Copy City of Salem, City Hall Amex /�o� ,�n� 120 Washington Street `fes,��v Salem,MA 01970 r Y GREETINGS: Constable ��// YOU ARE HEREBY COMMANDED in the name of the Commonwealth of Massachusetts in accordance with the provisions of Rule 45 of the Massachusetts Rules of Civil Procedure to appear and testify on behalf of the plaintiff, Dorothy Diane Linehan by and through her executor, Shawn Beaupre,before a Notary Public of the Commonwealth, at the offices of Paul E. Mitchell, Esq., Mitchell &DeSimone, 99 Summer Street, Boston, Massachusetts, at 10:00 a.m. on Wednesday,July 10,2002,and to testify as to your knowledge, at the taking of the deposition in the above-entitled action. The Keeper of Records is also requested to bring with him/her all items listed on schedule "A"attached hereto. PLEASE CONTACT ATTORNEY PAUL E. MITCHELL (617) 737-8300 UPON RECEIPT OF THIS DEPOSITION SUBPOENA Hereof fail not as you will answer your default under the pains and penalties in the law in that behalf and provided. f "'C Paul E. Mitchell, B.B.O. 4550941 No Public: Katherme Rui Mitchell & DeSimone My commission expires: 9/ 08 99 Summer Street Boston, MA 02110 (617) 737-8300 SCHEDULE A ` 1. Any and all file materials and documents concerning the documents located at 392 Essex Street. 2. Any and all file materials and documents of any nature concerning a fire at the property located at 392 Essex Street on January 13, 1999. 3. Any and all file materials and documents of any nature concerning inspection by the City of Salem (Building Inspector, Department or other individual, organization or entity) of the property located at 392 Essex Street at any time. 4. Any and all documents identifying or discussing the means of egress from the building located at 392 Essex Street at any time. 5. Any and all documents discussing fire retardant doors on the property located at 392 Essex Street at any time. Note: You may meet the requirements of this Subpoena by delivering clear copies of the requested documents to this office on or before the due date and avoid the necessity of a personal appearance. I 392 Essex Street L-1 NAME OR ADDRESS IIANIFEBJMAqAPRIMAIJUNIJULIAUqSEPICC NOV OE USE PURPOSE USED PROVIDE THE FOLLOWING INFORMATION AS APPLICABLE OF STORIES 3R R CLASS OF CONSTRUCTION DATE ERECTED CERTIFIED CAPACITY: (BY STORY OR TYPE) NUMBER OF ROOMS - HOSPITALS, SCHOOLS, HOTELS: (BY STORY OR TYPE) 1st- ant_ 1 - lrm & R 2- 2 rms & R 1- 2 rm= 13- 2 rms . B 14- 2 rms & B 15- 3 rms . & 1 ) 16- 2 rms & B 2nd- apt . 4- 2 rms . & B 5- 2 R- hath - Fi- 2 rms - ?- R 7- 2rms & R 17- 2 rms . 18- 3 rms ?� R IT-d- ant , 8- 2 rms - Rr R n- 2 rn R 10- 2 rms & R 11 - 2 rms & R 12- 2 rms . & NUMBER OF DWELLING UNITS PER STORY 1 n s ahnVp FORM SBCC-2-76 EMERGENCY LIGHTING SYSTEM MEANS OF DETECTING AND EXTINGUISHING FIRE - OF ELEVATORS HOW HEATED Steam by ni 1 BOILER OR OTHER HEATING APPARATUS HOW LIGHTED HOW VENTILATED PLACE OF ASSEMBLY: YES NO PURPOSE USED IN WHICH STORY STANDARD BOOTH INSTALLED LOCATION FIXED SEATING OF AISLES AND WIDTH FIRE RESISTANCE OF CURTAINS OR DRAPERIES OF SANITARIES2 0 LOCATION 4 OF GRADE FLOOR MEANS OF EGRESS DOORWAYS 6 OF SEPARATE STAIRWAYS ACCESSIBLE PER STORY Page 1 of SALEM HEALTH DEPARTMENT 9 North Street Salem,MA 01970 State Sanitary Code, Chapter If: 105,CMR 410.000 Minimum Standards of Fitness ion Human Habitation Occupant: Phone: 17YI— Address: ��4,2 FS S F z j Apt. _LY ` Owner. ZAm e,< 6alLc v Address: X_( SSR/_Fm /Ntz O/9'ly Inspect' ?--1/ q Conducted By:.Ver/,q to k/,S Accompanied By: Anticipated Reinspection Date: Specified Reg # , Violation Time 410. - 7✓-f- • /w GC —.O O ._ ..._ .. a t N� G' a L1151111L /S _. N ce e e ti N One or more of the above violations may endanger or materially impair the health, safety and well-being or-the l occupants(s) Code Enforcement Inspector Este es un documento legal importante. Puede que afecte sus derechos. rage t2- _ ui s7 ���� SALEM HEALTH DEPARTMENT "Date a-� Salem,.MA 01970 •a�+1 Name: Sdd, A-j /Al 7t/ Address: ,?q,Q A'6;; ZV Specified Reg tf Violation Time 410. . . . Ned-MA 11V4 /I e N / .. . / L - IAILIr o vl C f2U 7V U 3s O vLL e- Gb — 7va//wues2 Ile --- R ! s N av Qum- O L _ in 2 SooAS _._ 7 0 r o 7 T-7�.e-e IVO 9,vS P s W,CV�e-"fie *7 �U L Pr ce� ro•�r. CITY OF SALEM HEALTH DEPARTMENT BOARD OF HEALTH 9 North Street ROBERT E. BLENKHORN Salem, Massachusetts 01970 HEALTH AGENT 508-741-1800 September 16, 1993 Mr.James Bailey 81 Essex Street Salem,MA 01970 Dear Mr. Bailey: In accordance with Chapter 111,Sections 127A and 127B of the Massachusetts General laws. 105 CMR 400.00:State Sanitary Code.Chapter 1:General Administrative Procedures and 105 CMR 410.000:State Sanitary Code.Chapter It:Minimum Standards of Fitness fm,Human Habitation an inspection was made of your property at 392 ESSEX STREET in the City of Salem,Massachusetts by Virginia E Moustalds,Sanitarian for theSalem Health Department on September 16,1993. +t The following violations of the State Sanitary Code were noted,as checked off: • CMR 410:600 Storage of Rubbish and Garbage _ • CMR 410:601 Collection of Garbage and Rubbish X CMR 410.602 Maintenance of Areas Free From Garbage and Rubbish(A through D) X Reg.47 s..}.10 Board of Health Regulation Description of Violations: SEE ENCLOSED: 410.600: Storage of Rubbish and GwU" (A) Garbage or mixed garbage and rubbish shall be stored in watertight receptacles with tight-Ruing trovers.Said receptacles and covers shall be of metal or other durable,rodent-proof material.Rubbish shall be stored in receptacles of metal or other durable.rodem-proof material. Garbage and rubbish shall be put out for collection no earlier than the day of collection. (B) Plastic bags shall be used to store garbage or mixed rubbish and garbage only if used as a liner in watertight receptacles with tight-fiting covers as required in 105 CMR 410.600(A)provided that the plastic bags may be put out for collection except in those places where such p practice is prohibited by local rule or ordinance,or except in those cases where the Department of Public Health determines that such practice eoastimt<s a health problem For purposes of the preceding sentence.in nuking its determination.the Department shall consider.among other other evidence of strewn garbage,tom garbage bags,or evidence of rodents. (C) The owner of any dwelling that contains three or more dwelling units,the owner of any rooming house.and the occupant of any other dwelling place shall be responsible for providing as many receptacles for the storage of garbage and rubbish as are sufficient to contain the accumulation before final collection or ultimate disposal,and shall so locate them to be convenient to the tenant that no object iunzble odors enter any dwelling. (D) The occupants of each dwelling.dwelling unit,and rooming unit shall be responsible for the proper placement of her or his garbage and rubbish in the receptacles required in 105 CMR 410.600(C)or at the point of collection by the owner. 410.60E Collection of Garbage and Rubbish The owner of any dwelling that contains three or more dwelling units,the owner of any rooming house.and the occupant of any other dwelling place shall be responsible for the final colelection or ultimate disposal or incineration of carbage and rubbish by means of: (A) The regular municipal collection system;or (B) Any other collection system approved by the Board of Health;or (C) When otherwise lawful.a garbage grinder which grinds garbage into the kitchen sink drain finely enough to ensure its free passage,and is otherwise maintained sat as not to create a safety or health hazard;or (D) When otherwise lawful,a garbage or rubbish incinerator located within the dwelling which is properly installed and which is maintained so as not to create a safety or health hazed;or (E) Aoy other method of disposal which dues not endanger any person and which is approved in writing by the Board of Health (see 105 CMR 410.940) SALEM HEALTH DEPARTMENT ^` J; 9 North Street Salem. MA 01970 4„r VIOLATIONS 392 ESSEX STREET CONSTRUCTION MATERIAL PLACED OUT FOR MUNICIPAL COLLECTION MUST BE REMOVED AND BROUGHT TO AN APPROVED SITE-(FOREST STREET IN PEABODY FOR ONE) AND THE AREA CLEANED AND MAINTAINIED. ago � AMY � - p�-.�,�" 0019 007-4p 7' 0:2 O?ms T" ops rP&es vz—az—v� 4a : Zu uta 1V>� VXY ID=978 858 0869 P02/83 t �rzs�.Gr ��ae.. 1J01 ARGEO PAUL eEuuca c7'iLOs[� �f1lJ�P��POO owemar JANE 8WPT 5a v �fY1�7P1..91r9P Li@U*Nrd aovemor JANE PERLOw Seueury JOSEPH S.LALLI Acft Comma&wer February, 12,1999 Mark Murphy I 3 Laurel Street Salem,MA 01970 RE: 392 Essex St.Salem,Third Floor Egress Dear Mr,Murphy: This letter was written ut response to your inquiry as to whether the third floor of 392 Essex St., in Salem had two means of egress. On Tucsday, January 19, 1999, 1 met with the Salem Building Commissiotur, Peter Strout,and inspected the said property. The third floor consisted of 6 dwelling units,each having I door exiting into an L shaped corridor; these doors were not of fire rated construction. At each end of the corridor there were open stairways leading to the exterior on the first floor. At the middle of the corridor there was a door splitting the corridor in half,this door was not of fire rated construction. Also,there were no exit signs at the time of the inspection The building was certified as a lodging louse in 1974- The Building code in force at that time of perm t�g was theme Bwere O CA Basic Building Code of 1970(the code). Upon reviewing the code the following Vioti1. There was no enclosed independent stairway as required by Section 611.0, Section 611.0, Number of Exitways, states: There shall not be less than two (2) approved independent exirweip serving every floor area stairway... above and below the first or grade floor, at least one (1) of which shall be an interior enclosed 2. There were no doors enclosing either stairway as required by Section 618.6, and Section 917. Section 618.6, Stair Exitway Doors,requires that: "All doorway opening protectiecs, including the frames and hardware, shall be approved self-closing swinging doors complym with article 9. Article 9, Section 917 , Fire Doors, requires stairway doors to be at least 1 % inch solid core wood doors for all residential construction. Tewksbury District Office, Dietary Building, East Street, Tewksbury, MA 01876 Phone: 978-8S1-9813 Fax: 978-858-0869 02-12-99 11 : 28 DPS TEWKSBURY ID-978 858 0869 P03/03 l � 3. There were no exit signs ble at the time 625.0,Exit Signs and Ligh , equires all cans of Potion as required by Section 625.0. Section signs egress to be indicated with approved metal"EXIT„ Additionally,The Sixth Edition of the Massachusetts State Building Code(780 CMR),the current code in forts, indicates in Section 1004.2.1 Exit Order/Hazardous Means of Egress,that: In any existing building or structure not provided with exit facilities as herein prescribed for new buildings and in which rhe exits are deemed hazardous or dangerous to life and limb, the building offraral shall declare such building dangerous and unsafe in accordance with the provisions of 780 CMR 121.0. In accordance with 780 CMR Section 1004.2.1 the following section was not provided for, and in my opinion hazardous to life and limb: Section 1006.4 Remote Location,which states: Wherever more than one exit is required from any room, space or floor oja Building, such exits shall be placed as remote from each other as practicable, and shall be arranged and constructed to provide direct access in separate directions from any point in the area served so as to minimize the possibility that both exits will be blocked by any one condition. fire or other emergency In this ease there was only ate means of egress from within each dwelling unit. In conclusion,the BOCA Basic Building Code of 1970 required one of the stairways to be enclosed with approved materials and door construction. In addition,all means of egress were required to be marked with approved "EXIT' signs. The current building code, 780 CMR, required the said building to have two means of egress to provide direct access in separate directions from any point in the area served. None of these were provided for on the third floor of 392 Essex Stroet,Salem at the time of the inspection. If you have any further questions or comments please do not hesitate to call. Sincerely, Derek I. Creaser State Building Inspector cc: Tom Rogers,DPS Peter Strout, Building Commissioner .. coaolr4 4atma�� CITY OF SALEM HEALTH DEPARTMENT BOARD OF HEALTH 9 North Street ROBERT E. BLENKHORN Salem, Massachusetts 01970 HEALTH AGENT 508-741-1800 September 16, 1993 Mr.James Bailey 81 Essex Street Salem,MA 01970 Dear Mr. Bailey: In accordance with Chapter 111,Sections 127A and 127B of the Massachusetts General laws,105 CMR 400.00:State Sanitary Cade.Chapter 1:General Administrative Procedures and 105 CMR 410.000:Slate Sanitary Code,Chapter II:Minimum Standards of Fitness for Human Habitation.an inspection was made of your property at 392 ESSEX STREET in the City of Salem,Massachusetts by Virginia E.Moustakls,Sanitarian for lheSalem Health Department on September 16,1993. The following violations of the State Sanitary Code were noted,as checked off: • CMR 410:600 Storage of Rubbish and Garbage • CMR 410:601 Collection of Garbage and Rubbish X CMR 410:602 Maintenance of Areas Free From Garbage and Rubbish(A through D) X Reg.q7 s.3.10 Board of Health Regulation Description of Violations: SEE ENCLOSED: 410.600: Storane of Rubbish and GgrbAgg. (A) Garbage or mixed garbage and rubbish shall be stored in watertight receptacles with tight-fitting covers.Said receptacles and covers shall be of metal or other durable,rodent-proof material.Rubbish shall be stored in receptacles of metal or other durable,rodent-proof material. Garbage and rubbish shall be put out for collection no earlier than the day of collection. (B) Plastic bags shall be used to store garbage or mixed rubbish and garbage only if used as a liner in watertight receptacles with tight-filing covers as required in 105 CMR 410.600(A)provided that the plastic bags may be put out for collection except in those places where such p practice is prohibited by local rule or ordinance,or except in those cases where the Department of Public Health determines that such practice constitutes a health problem For purposes of the preceding sentence,in making its determination,the Department shall consider,among other other evidence of strewn garbage,tom garbage bags,or evidence of rodents. (C) The owner of any dwelling that contains three or more dwelling units,the owner of any rooming house.and the occupant of any other dwelling place shall be responsible for providing as many receptacles for the storage of garbage and rubbish as are sufficient to contain the accumulation before final collection or ultimate disposal,and shall so locate them to be convenient to the tenant that no objectionable odors enter any dwelling. (D) The occupants of each dwelling,dwelling unit,and rooming unit shall be responsible for the proper placement of her or his garbage and rubbish in the receptacles required in 105 CMR 410.600(C)or at the point of collection by the owner. 410.601:Collection of Garbage and Rubbish The owner of any dwelling that contains three or more dwelling units,the owner of any rooming house,and the occupant of any other dwelling place shall be responsible for the final colelection or ultimate disposal or incineration of garbage and rubbish by means of: (A) The regular municipal collection system;or (B) Any other collection system approved by the Board of Health;or (C) When otherwise lawful,a garbage grinder which grinds garbage into the kitchen sink drain finely enough to ensure its free passage,and is otherwise maintained so as not to create a safety or health hazard;or (D) When otherwise lawful,a garbage or rubbish incinerator located within the dwelling which is properly installed and which is maintained so as not to create a safety or health hazard;or (E) Any other method of disposal which does not endanger any person and which is approved in writing by the Board of Health (see 105 CMR 410.840) yVr`y,rrbC-` SALEM HEALTH CEPAPTMENT 9 North Street Salem, MA 01970 410.602: Maintenance of Areas Free From Garbage and Rubbish (A) Land: The owner of any parcel of land,vacant or otherwise,shall be responsible for maintaining such parcel of land in a clean and sanitary condition and free from garbage,rubbish,or other refuse.The owner of such parcel of land shall correct any condition caused by or on such parcel or its appurtenance which affects the health or safety and well-being of the occupants of any dwelling or of the general public. (B) Dwell ing,Units: The occupant of any dwelling unit shall be responsible for maintaining in a clean and sanitary condition and free of garbage, rubbish,other filth or causes of sickness that pan of the dwelling which s/he exclusively occupies or controls. (C) Dwellings Containing Fewer Than Three Dwellin Units: In a dwelling that contains fewer than three dwelling units,the occupant shall he responsible for maintaining in a clean and sanitary condition free of garbage,rubbish,other filth or causes of sickness the stairs or stairways leading to her or his dwelling unit and the landing adjacent to her or his dwelling unit if the stairs.stairways,or landing are not used by another occupant. (D) Common Areas: In any dwelling,the owner shall be responsible for maintaining in a clean and sanitary condition free of garbage,rubbish, other filth or mases of sickness that part of the dwelling which is used in common by the occupants and which is not occupied or controlled by me occupant exclusively. (i)The owner of any dwelling abutting a private passageway or right-of-way owned or wed in common with other dwellings or which the owner or occupants under her or his control have the right to use or are in fact using shall be responsible for maintaining in a clean and sanitary condition free from garbage,rubbish,other filth or cause of sickness that pan of the passageway or right-of-way which abuts her or his property and which s/he or the occupants under her or his control have the right to use,are in fact using,or which s/he owns. Board of Health Regulation#7 Section 3 10: Containers or Bundles of Household and Ordinary Commercial Waste.Garden and Lawn Waste: These shall be placed at the outer edge of the sidewalk appurtenant to the premises of the owner not later than 7:00 a.m.on the day of collection and not before 6:00 p.m.on the day preceding the day of collection,and shall be removed from the sidewalk on the same day as emptied.No commercial establishment shall place or cause to be placed more than four barrels or other containers of ordinary commercial wastes or any extraordinary commercial or industrial wastes or tree waste upon any sidewalk or way for disposal You are hereby Ordered to make a good faith effort to correct these violations within 24(twenty four)hours of receipt of this notice. Failure on your part to comply within the specified time will result in a complaint being sought against you in Salem District Court. Should you be aggrieved by this order,you have the right to request a hearing before the Board of Health. A request for said hearing must be received in writing in the office of the Board of Health within 7 Days of receipt of this order. At said hearing,you will be given an opportunity to be heard and to present witness and documentary evidence as to why this order should be modified or withdrawn. You may be represented by an attorney. Please also be informed that you have the right to inspect and obtain copies of all relevant inspection or investigation reports,orders,and other documentary intormation in the possession of this Board,and that my adverse party has the right to be present at the hearing. One or more of the above violations constitutes a condition which may endanger or materially impair the health or safety and well-being of the occupant(s) or the general public. If you have any questions,kindly contact this office at(508)741-1800. For the Board of Health Reply to: Robert E.Bleakhoru,C.H.O. Virginia E.Moustakis Health Agent Sanitarian Certified Mail P 348 636 051 ce; Ward Councillor Building Inspector 3 CITY OF SALEM BOARD OF HEALTH Salem, Massachusetts 01970-3928 JOANNE SCOTT, MPH, RS, CHO NINE NORTH STREET HEALTH AGENT Tel (978)741-1800 February 19, 1998 Fax: (978)740-9705 James A. & Claire Bailey 01 IJV 81 Essex Street _ Salem, MA. 01970 Dear Sir / Madam : In accordance with Chapter II of the State Sanitary Code, 105 CMR 410.000, Minimum Standards of Fitness for Human Habitation, a recent reinspection was conducted of your property located at 392 Essex Street Apt.#14 by Virginia Moustakis, Senior Sanitarian of the Salem Health Department on Thursday, February 19, 1998. The violations noted in the report of February 5, 1998 have been corrected. Thank you for your cooperation in this matter. For the Board of Health : Reply to: Joanne Scott Virginia Moustakis Health Agent Senior Sanitarian cc: Tenant, Fire Preventio Building Dept. Electrical Dept., & Councillo -R—Flynn JS/sjk C-hW ct SALEM HEALTH CEPARTMENT �^ �p 9 North Street Salem, MA 01970 410.602: Maintenance of Area Free From Garbage and Rubbish (A) Lam: The owner of any parcel of land,vacant or otherwise,shall be responsible for maintaining such parcel of land in a clean and sanitary condition and free from garbage,rubbish,or other refuse.The owner of such parcel of land shall correct any condition caused by or on such parcel or its appurtenance which affects the health or safety and well-being of the occupants of any dwelling or of the general public. (B) Dwelling Units: The occupant of any dwelling unit shall be responsible for maintaining in a clean and sanitary condition and free of garbage, mbbish,Other filth or causes of sickness that part of the dwelling which s/he exclusively mcupies or controls. (C) Dwellings Containing Fewcr Than Three Dwelling Units: In a dwelling that contains fewer than three dwelling units,the occupant shall be responsible for maintaining in a clean and sanitary condition free of garbage,rubbish,Other filth or causes of sickness the stairs or stairways leading to her or his dwelling unit and the landiag adjacent to her or his dwelling unit if the stairs,stairways,or landing are not used by another occupant. (D) Common Areas: In any dwelling,the owner shall be responsible for maintaining in a clean and sanitary condition free of garbage.rubbish, other filth or cusses of sickness that part of the dwelling which is used in common by the occupants and which is not occupied or controlled by the occupant exclusively. (i)The owner of any dwelling abutting a private passageway or right-of-way owned or used in common with other dwellings or which the owner or occupants under her a his control have the right to use or are in fact using shall be responsible for maintaining in a clean and sanitary condition free from garbage,rubbish,other filth or cause of sickness that part of the passageway or right-of-way which abuts her or his property and which s/he or the occupants under her or his control have the right to use.are in fact using,or which vhe owns. Board of Health Reputation#7 Section 1.10: Containers or Bundles of Household and Ordinary Commercial Waste.Garden and I awn Wane: These shall be placed at the outer edge of the sidewalk appurtenant to the premises of the owner not later than 7:00 a.m.on the day of collection and not before 6:00 p.m.on the day preccdiag the day of collection.and shall be removed from the sidewalk on the sane day as emptied.No commercial establishment shall place or cause to be placed more than four barrels or Other containers of Ordinary commercial wastes a any extraordinary commercial"industrial wastes or tree waste upon any sidewalk or way for disposal..R You are hereby Ordered to make a good faith effort to correct these violations within 24(twenty four)hours of receipt of this notice. Failure on your part to comply within the specified time will result in a complaint being sought against you in Salem District Court. Should you be aggrieved by this"der,you have the right to request a hearing before the Baud of Health. A request for said hearing must be received in writing in the office of the Board of Health within 7 Days of receipt of this order. At said hearing.you will be given an opportunity to be heard and to present witness and documentary evidence as to why this order should be modified"withdrawn. You may be represented by an attorney. Please also be informed that you have the right to inspect and obtain copies of all relevant inspection or investigation reports.orders,and other documentary intormation in the possession of this Board,and that any adverse party has the right to be present at the hearing. One m more of the above violations constitutes a condition which may endanger or materially impair the health or safety and well-being of the occupant(s) or the general public. If you have any questions,kiodly contact this office at(508)741.1800. For the Board of Health Reply to: Robert E.Blenkhorn.C.H.O. Virginia E.Moustakis Health Agent Sanitarian Certified Mail P 348 636051 cc; Ward Councillor Building Inspector I"v r U m PIK `I cows 1 0 9 30106 CERTIFICA E OF OCCUPANCY CITY OF SALEM Issued. 00 Per 9 mph: G9k-9 SALEM, MASSACHUSETTS 01970 City of Salem Bu(IdihfNIpt �a !LN 1T 5 UNLy DATE OCTOE+ER (Z1E, TS 99 PERMIT NO. 598-199' GEORGE T. T RNCri ADDRESS 23 ARr:!ELLA. STREET 1969 OON RB UCENSEI APPLICANT (N0.) (STREET) clTv SALEM STATE t'IA ZIP CODE 0197 IZI TEL.NO. 978-667-2446 PERMIT TO REPAIR REPLACE-, I_) sroav TWD Ok MORE FAM i LY DWELNUMBLING UNITS lk (TYPE OF IMPROVEMENT) NO. (PROPOSED USE) ZONING AT(LOCATION) 039'2: ESSEX STREET DISTRICT R!_ (NO.) (STREET) BETWEENAND (CROSS STREET) (CROSS STREET) LOT 0(IZQi9c4-0 SC! FT SUBDIVISION MAP '=c LOT-2-L712-9 BLOCK SIZE BUILDING IS TO BE FT.WIDE BY FT.LONG BV FT.IN HEIGHT AND SHALL CONFORM IN CONSTRUCTION TOTYPE USEGROUP BASEMENT WALLS OR FOUNDATION (TYPE) REMARKS: 2ND PERMIT FOR ADI:7ITIONAL RECONSTRUCTION FROM FIRE DAMAGE. PLANE S!UBMITT'EC CC PERMIT i 75�! 00 AREA OR ESTIMATED COST$ 1.7,c:;. (ZANY_( FEE VOLUME (CUBICISOUARE FEET) OWNER BAILEY .JAMES A BUILDING DEPT, ADDRESS 81 ESSEX ST By T. J. s THIS PERMIT CONVEYS NO RIGHT TOOCCUPY ANV STREET.ALLEY OR SIDEWALK OR ANY PART THEREOF,EITHER TEMPORARILY OR PERMANENTLY,ENCROACHMENTS V� I` LI. cop, 0 CITY OF SALEM Ci of Salem Buildin DepM SALEM, MASSACHUSETTS 01970 DATE LICTOPF., FR lzicj 19 19.3 PERMIT NO. 698":1.999 APPLICANT CI: O'RGF T. I A NCH ADDRESS 23 ARIBELL-A Sl REE 1 196;9 (NQ) (STREET) (CONTE 5 LICENSE) CITY S A L.E iyi STATE 1y16-a ZIPCODE171 TEL.NO. 97B-6,67 -L-.:-4zi6 OF PERMIT TO 1:.:,.PA I R Rr..-PL-ACI­MF.:N STORY TWO OR MORE FAillLNUMBER Y DWELLING UNITS (TYPE OF IMPROVEMENT) NO, (PROPOSED USE) AT(LOCATION) ESSF.: X 53T REE. F ZONING DISTRICTRI - (NO) (STREET) BETWEEN AND (CROSS STREET) (CROSS STREET) -) LOT 0132/10 SGI F F SUBDIVISION MAP 25 LOT '2)0�9 BLOCK— SIZE 710 BUILDING IS TO BE FT.WIDE BV FT.LONG BV Fr.IN HEIGHT AND SHALL CONFORM IN CONSTRUCTION TO TYPE USE GROUP BASEMENT WALLS OR FOUNDATION (TYPE) REMARKS: 2-ND FIERWIT FOR FiDIA-1 IDNAL REC01,ISFIRILK.J.101\1 FROM FIRE DAly1AC-3E. P1 ANS Uf:illl T I ED", AREA OR PERMIT VOLUME ESTIMATED COST$ :1.75, @0 FEE $ 1 751;,� 0 . QtO (CUBIC/SQUARE FEET) OWNER DAILEY -INYIES A BUILDING DEPT. ADDRESS 81 E�.:;SF X BY T. J. Cr. ow", Ir. ILDING RMIT DATE APPLICANT 19- PERMITNO.— ADDRESS E-( FNO—) (STREET) --(CONTR S—LICENSE) ir CITY ------ STATE ZIP CODE TEL.NO. Z!G 'j TIL NUMBEROF PERMITTO STORY rli�!! DWELLING UNITS NU, —(IYHEOEIMFR VNEMOT) (PROPOSED USE) AT(LOCATI ZONING DISTRICT�–'— BETWEEN AND (CROSS STREET) (CROSS STREET) SUBDIVISION LOTLOT BLOCK— SIZE BUILDING ISTOBE—FT,WIDEBY—FT.LONG BV FT.IN HEIGHT AND SHALL CONFORM INCONSTRUCTION TOTYPEUSE GROUP BASEMENT WALLS OR FOUNDATION (TYPE) l REMARKS: U IT 12 AREA OR r PERMIT$ CEJ 'IccupY ESTIMATED VOLUME COST$ FEE (CUBIC/ I L OWNER y BUILDING DEPT. S BY j ADDRESL -S THIS PERMIT CONVEjgyf N TOO ANY STREET,ALLEY OR SIDEWALK OR ANY PART THEREOF.EITHER TEMPORARILY OR PERMANENTLY,ENCROACHMENTS PER N C ILL RMrrrED UNDER THE BUIL I DING C I ODE,MUST BE APPROVED BY THE JURISDICTION,STREET OR ALLEY GRADES AS WELL Z F - S B OM SON RESTRICTIONS. PLANS MUST I I L FINAL L I� F OCCUPANCY PRO PI U IL oll� ON PUBLIC PROPER ,hLO UBLIFICAL AS DEPTH AND LOCA Mb LIC SEWERS MAY BE OBTAINED FROM THE DEPARTMENT OF PUBLIC WORKS.THE ISSUANCE OF THIS PERMIT DOES NOT RELEASE THE UB APPLICANT FROM TH 0 DNIONS OF ANY APPLICABLE SUBDIVISION RESTRICTIONS. MINIMUM OFTHREEC I-LfSPECTIONS APPROVED PLANS MUST BE RETAINED ON JOB AND THIS CARD KEPT WHERE APPLICABLE SEPARATE F U T REQUIRED FOR ALL C N RU(3%rIONWORK PERMITS ARE REQUIRED FOR I POSTED IN S 1.FOUNDATIONS OR FOOTINGS, POSTED UNTIL FINAL INSPECTION HAS BEEN MADE. WHERE A ELECTRICAL,PLUMBING AND 2.PRIOR TO COVER STRUCTURAL CERTIFICATE OF OCCUPANCY IS REQUIRED,SUCH BUILDING SHALL MECHANICAL INSTALLATIONS. MEMBERS(RE NOT OCCUPIED ALYID LATH). NOT BE OCCUPIED UNTIL FINAL INSPECTION HAS BEEN MADE. FORE 3.FINAL INSP-- FOREOCCUPAN Y. - P 0 ft 1 4 0 THIS CARD SO IT IS VISIBLE FROM STREET BUILDING INSPECTION APP OVALS PLUMBING INSPECTIPV APPROVALS ELECTRICAL INSPECTION APPROVALS 2 2 2 BOARD OF HEALTH GAS IN §PECTION APPROVALS EPT INSPECTING APPROVALS e/ OTHER CITY ENGINEER 2 2 WORK SHALL NOT PROCEED UNTIL THE PERMIT WILL BECOME NULL AND VOID IF CONSTRUCTION WORK IS INSPECTIONS INDICATED ON THIS CARD INSPECTOR HAS APPROVED THE VARIOUS NOT STARTED WITHIN SIX MONTHS OF DATE THE PERMIT IS ISSUED CAN BE ARRANGED FOR BY TELEPHONE STAGES OF CONSTRUCTION S NOTED ABOVE. OR WRITTEN NOTIFICATION. s t• r u Q. 0 m 6 1a ifpfh;� 30 August 2000 Revised 31 August 2000 Thomas St. Pierre, Assistant Building Inspector City of Salem Building Department One Salem Green Salem, MA 01970 Project: Restoration & Reconstruction of the Ives-Putnam House 392 Essex Street, Salem, MA Subject: TEMPORARY CERTIFICATE OF OCCUPANCY Dear Mr. St. Pierre: Based on conversations with the owner, James Bailey and yourself, I understand that the owner has received final approvals from the Salem Fire Department and the Salem Electrical Inspector regarding the fire protection (sprinkler) system and fire alarm system based on successful testing and inspection of the systems and components. On Wednesday August 30th, I made a visit to the site with our mechanical consultant Steven Forte of Forte Engineering to complete a visual review and inspection of the work completed to date with the objective of determining which units are ready for occupancy, and to confirm what, if any additional work or remedial work will be required in order to bring the project to 100% completion and ready for Certificate of Occupancy. It is my understanding that the owner has requested approval of a Temporary Certificate of Occupancy, and that it can be issued by your office based on receipt of written confirmation from me that certain units are ready for occupancy, but with the stipulation that any outstanding or remedial work so identified must be completed within 30 days of the date of issuance of a Temporary Certificate of Occupancy. This letter shall serve therefore, to confirm that the following apartment units have been inspected and that to the best of my knowledge, information and belief, the work associated with the sprinkler a and fire alarm systems within each of the following apartment units as well as the common areas, o exit stairs and corridors and halls at the subject Project was generally,,completed in accordance with the approved Shop Drawings and As-Built Drawings submitted by the Design/Build Contractors, and n in accordance with the requirements of the Massachusetts State Building Code. m rn The following apartment units are ready for occupancy: First Floor Unit 3 mt m Second Floor Unit 8 Unit 9 E Unit 10 Unit I1 u; m b y x m W N r ,.A j Thomas St. Pierre, Assistant Building Inspector 30 August 2000 Page 2 Third Floor Unit 15 will be ready for occupancy only after the DesignBuild Sprinkler Contractor has adjusted the deflector at sidewall sprinkler head such that the deflector is positioned parallel with the ceiling plane above. We will provide you with a copy of our Field Report that outlines our observations and findings regarding the remedial repairs and additional work required to complete the project within the next 30 days. Our Field Report will be sent to you under separate cover immediately upon its completion. If you have any questions in the interim, please do not hesitate to contact me. 30 August 2000 �i� azure: j Date: G\S.�EpED 'q�h,f P FOS e n 0 No.6401 m SALEM, W 02� MA ,tJy 4 F9<Ty 0,N\SSP Daniel H. Pierce, AIA 6401 Architect: Mass. Reg. No. copy: James Bailey 0392 ESSEX STREET G58-2000 COMMONWEALTH OF MASSACHUSETTS �..: CITY OF SALEM ciso # Map c .ffs::25 m is ,, u a��H�. Block-, FE ;h;��; GAS PERMIT LOt �� fi:0099 s s2'tryf?`�' t L. ,rlts PermlC 54 Category Ii V Viii II:. f Pemlt# c58-2000 Ef°' PERMISSIONISHEREBY GRANTED TO: Project# ?„JS-2001-0269 Est Cost I `;$0 00 Contractor: License: �+ s s. 4hcRIF Fee $38.00 -- � ,� 0 t a J.P.0ampbell,Inc Plumb ng/Gas-#9050-M �x ru(RI: 4{I #`of Flxtu4resLL` ,' ,; t_y;„Owner: BAILEY JAMES A Applicant: J.P.Campbell,Inc AT: 0392 ESSEX STREET ISSUED ON. 28-Aug-2000 AMMENDED ON. EXPIRES ON: 28-Feb-2001 TO PERFORM THE FOLLOWING WORK. Basement- 1 heating boiler,2 dryers THIS PERMIT MAY BE REVOKED BY THE CITY OF SALEM UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: GAS REC-2001-000301 28-Aug-00 01 $38.00 GcoTMSO 2003 Des Lauriers Municipal Solutions,Inc. 0392 ESSEX STREET G118-2003 COMMONWEALTH OF MASSACHUSETTS CITY OF SALEM cls Map 25 Block: GAS PERMIT Lot rs -=0099 Permit: Gass`' O � Category ' '434 Residential additi6ns;a T� . �.; Pet�nit# .y aIle-2oo3 ; �- a PERMISSION IS HEREBY GRANTED TO: ProJect# JS7S-2003-0737 n: Est: Cost :$0 00 r y Contractor: License: L f „ n s O'Regan Plumbing&Heating Plumbing/Gas-#12103 -M Fee. "$470 00 m, .M #of Features 1. r-Owner: BAILEY JAMES A Applicant: BAILEY JAMES A AT. 0392 ESSEX STREET ISSUED ON: 09-Sep-2002 AMMENDED ON: 09-Sep-2002 EXPIRES ON: 09-Mar-2003 TO PERFORM THE FOLLOWING WORK. G118-2003 15 NEW HEATING BOILERS APTS. 1-16 REQ.BY KEN CARPLJLC THIS PERMIT MAY BE REVOKED BY THE CITY OF SALEM UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature: Fee Type: Receipt No: Date Paid: Check No: Amount: GAS REC-2003-000808 09-Sep-02 2336 $470.00 GeoTMSO 2003 Des Lauriers Municipal Solutions,Inc. ■ m s m i u Q m m m 'a SUBMITTALS REVIEW Date: 17 September 1999 Submittal No.: 9904-16.1 To: PENNEY ELECTRICAL CORP. 3 Daniel Drive Stoneham, MA 02180 Project: onstruction of the Ives-Putnam House It x ;PSI alem, MA Description: Design/Build Drawings for proposed Fire Alarm System at the referenced Project. Remarks: Not Approved/ vise & Resubmit This project is subject to the requirements of Section 116 of the Massachusetts State Building Code for Construction Control. Revise and resubmit Design/Build Drawings for review and approval by the Architect prior to submittal to the City of Salem,Fire Prevention Bureau and Building Department. Design/Build Contractor shall confirm all as-built and existing conditions at the project site. Revise and resubmit Drawings as noted on the attached markings with accompanying Product Data and other Submittals as noted. Provide new and/or revised Drawings that include the following: • Basement Plan indicating all existing partitions, structure and spaces requiring protection. • Provide a separate Attic Level & Loft Level Plan showing all partitions, structure, m skylights, coordinated with same, and indicated how spaces are to be protected. Action Stamp: ❑ No Exceptions Taken Ill Not Approved 1 LL ❑ Note Markings Revise and Resubmit N Resubmittal Not Required m n m ❑ Note Markings o Resubmittal Required m 0 Reviewing is only for conformance with design concept of the work and with the information given in the >" Contract Documents. The Design/Build Contractor is solely responsible for dimensions to be confirmed and y correlated at the site,for information that pertains solely to the fabrication processes or to the means,methods, ;? techniques,sequences and procedures of construction,and for the coordination of the work of all trades.-, U . Submission No. .9�d �A� J m Bv Date /7 E m te l a/ �4e i fFi� Copy: James Bailey, Own IW!Cdr� e8 U114C/�8 �� y N W N n RIC. #119912 Q®(y'QD [ o Qo }O�a LIC. # 065075 GENERAL CONTRACTORS For the Restoration & Reconstruction project for: Mr. and Mrs. Bailey 81 Essex Street Salem Ma. 02115 978-745-0685 Project: Ives Putnam House 392 Essex Street Salem Ma. 02115 RE: Final completion of contract August 13, 1999 This memorandum is to inform all involved in this project that all inspections and requirements of SCI. have been completed and are ready for final inspection by any agents of the owners of this project. This will also be notification that as of this date, August 18, 1999, SCI. will no longer be the permit holder on this project. SCI. will no longer have any responsibility there of. There for after this date any work of any kind that may be deemed permit worthy by the Cry of Salem, will be responsibility of some other entity. Copy: James Baily, W. Hobbs Endeavors Corp. Pierce Architects Peter Strout, City of Salem Building Inspector Since Robert M Slocum, President P. 0. Box 640 • North Reading, MA 01864 • (978) 664-3808 • Custom Homes &Additions • Design/Build • Decks • Windows • Siding • Kitchens S Baths 1 (fitp of *alemc, �fla!65atbu!6ett5 w Public Propertp Mepartment Wuilbing IDepartment One&a[em green (97S) 745-9595 ext. 3S0 Peter Strout Director Public Property of Inspector of Buildings .. Zoning Enforcement Officer January 22, 1999 James Bailey 81 Essex Street Salem, Ma. 01970 RE: 392 Essex Street Dear Mr. Bailey: This is to inform you that we will need a structural report relative to the current stability of the building at 392 Essex Street due to fire damage. You will need to act on the reconstruction of the property in an expedient time frame to ensure the safety of the neighborhood and the general public. Thank you for your anticipated cooperation in this matter. Sincerel , Peter St ut Inspector of Buildings cc: Al Viselli Councillor Flynn, Ward 2 \1 Y ROBERT J. SWAJIAN & ASSOCIATES, INC. INSURANCE ADJUSTERS 161 SOUTH MAIN STREET MIDDLETON,MA 01949 TELEPHONE(978)777-1400 FAX(978)777-2255 FORM OF NOTICE OF CASUALTY LOSS TO BUILDING UNDER MASS. GEN. LAWS, CH. 139, SEC. 3B TO: Building Commissioner or Board of Health or Inspector of Buildings Board of Selectman SALEM, MA 01970 RE: Our File No: RJS-26892 Insured: Bailey, James 81 Claire Loss Location: 392 Essex St., Salem Date of Loss: 1-3-99 Policy Number: CPP701 1607-12 Claim has been made involving loss, damage or destruction of the above captioned property, which may either exceed $1,000.00 or cause Mass. Gen. Laws, Chapter 143, Section 6 to be applicable. If any notice under Mass. Gen. Laws, Chapter 139, Section 3B is appropriate please direct it to the attention of the writer and include a reference to the captioned insured, location, policy number, date of loss, and claim or file number. ADJUSTERS TITLE: On this date, I caused copies of this notice to be sent to the persons named above at the addresses indicated above by first class mail. JAN. 209 1999 DATE Ybrvn[ ` GSSIXNKAi ' um[v[wpu� iusuonu¢ noble[ m r m Q m m `m 'a SUBMITTALS REVIEW Date: 17 September 1999 Submittal No.: 9904-16.1 To: PENNEY ELECTRICAL CORP. 3 Daniel Drive Stoneham, MA 02180 Project: ton nstruction of the Ives-Putnam House 392 Essex Street Salem, MA Description: Design/Build Drawings for proposed Fire Alarm System at the referenced Project. Remarks: Not Approved/ vise & Resubmit This project is subject to the requirements of Section 116 of the Massachusetts State Building Code for Construction Control. Revise and resubmit Design/Build Drawings for review and approval by the Architect prior to submittal to the City of Salem Fire Prevention Bureau and Building Department. Design/Build Contractor shall confirm all as-built and existing conditions at th e� project site. Revise and resubmit Drawings as noted on the attached markings with accompanying Product Data and other Submittals as noted. Provide new and/or revised Drawings that include the following: • Basement Plan indicating all existing partitions, structure and spaces requiring protection. • Provide a separate Attic Level & Loft Level Plan showing all partitions, structure, p skylights, coordinated with same, and indicated how spaces are to be protected. N Action Stamp: ❑ No Exceptions Taken Idl Not Approved LL „ 11 ❑ Note Markings Revise and Resubmit ut Resubmittal Not Required n Go n rn ❑ Note Markings o Resubmittal Required rn 0 Reviewing is only for conformance with design concept of the work and with the information given in the Contract Documents. The Design/Build Contractor is solely responsible for dimensions to be confirmed and m correlated at the site,for information that pertains solely to the fabrication processes or to the means,methods, t techniques,sequences and procedures of construction,and for the coordination.of the work of all trades. . - -Submission No. Bv Date /7 E m m Copy: James Bailey, Own in w N f` m L L Y a-a 2 Y Y d r 1aif fle-g 30 August 2000 Revised 31 August 2000 Thomas St. Pierre, Assistant Building Inspector City of Salem Building Department One Salem Green Salem, MA 01970 Project: Restoration & Reconstruction of the Ives-Putnam House 392 Essex Street, Salem, MA Subject: TEMPORARY CERTIFICATE OF OCCUPANCY Dear Mr. St. Pierre: Based on conversations with the owner, James Bailey and yourself, I understand that the owner has received final approvals from the Salem Fire Department and the Salem Electrical Inspector regarding the fire protection (sprinkler) system and fire alarm system based on successful testing and inspection of the systems and components. On Wednesday August 30th, I made a visit to the site with our mechanical consultant Steven Forte of Forte Engineering to complete a visual review and inspection of the work completed to date with the objective of determining which units are ready for occupancy, and to confirm what, if any additional work or remedial work will be required in order to bring the project to 100% completion and ready for Certificate of Occupancy. It is my understanding that the owner has requested approval of a Temporary Certificate of Occupancy, and that it can be issued by your office based on receipt of written confirmation from me that certain units are ready for occupancy, but with the stipulation that any outstanding or remedial work so identified must be completed within 30 days of the date of issuance of a m Temporary Certificate of Occupancy. This letter shall serve therefore, to confirm that the following apartment units have been inspected and that to the best of my knowledge, information and belief, the work associated with the sprinkler a and fire alarm systems within each of the following apartment units as well as the common areas, o exit stairs and corridors and halls at the subject Project was generally.,completed in accordance with the approved Shop Drawings and As-Built Drawings submitted by the Design/Build Contractors, and e in accordance with the requirements of the Massachusetts State Building Code. m m The following apartment units are ready for occupancy: m First Floor Unit 3 nrt—5 - Second Second Floor Unit 8 Unit 9 E Unit 10 m Unit I N m 5 w x d w n ■ u d L Y Q d Y `d a r19ra� SUBMITTALS REVIEW Date: 17 September 1999 Submittal No.: 9904-15.1 To: B &T Contracting 29 Juniper Drive Saugus, MA 01906 Project: n nstruction of the Ives-Putnam House 392 Essex Street alem, MA Description: Design/Build Drawings for proposed Sprinkler System at the referenced Project. Remarks: Approved./ evise & Resubmit T is project is subject to the requirements of Section 116 of the Massachusetts State Building Code for Construction Control. Revise and resubmit Design/Build Drawings for review and approval by the Architect prior to Submittal to the City of Salem Fire Prevention Bureau and Building Department. Design/Build Contractor shall confirm all as-built and existing conditions at the project site. Revise and resubmit Drawings as noted on the attached markings with accompanying Product Data and other Submittals as noted. Provide new and/or revised Drawings that include the following: • Basement Plan to indicate all existing partitions, structure and spaces. • Stair plans at all levels shall be revised to correctly indicate spaces under stairs, direction of travel, doors and landings, etc. ^ • Provide a separate Attic Level & Loft Level Plan showing all partitions, structure, a skylights, etc. making note of unheated Attic spaces and how coverage shall be ^ provided. m Action Stamp: M C? E] No Exceptions Taken Not Approved v ^ m m ❑ Note Markings Revise and Resubmit Resubmittal Not Required 0 Note Markings y Resubmittal Required Reviewing is only for conformance with design concept of the work and with the information given in the Contract Documents. The Design/Build Contractor is solely responsible for dimensions to be confirmed and m correlated at the site,for information that pertains solely to the fabrication processes or to the means, methods, techniques,sequences and procedures of construction,and for the coordination of the work of all trades. a ` m Submission No. ��] /C'�, y BY 9 7 m Copy: James Bailey,Owner W HOBBS ENDEAVOUR CORPORATION Consultants in the Engineering Sciences 34 Rockland Street,Swampscott,MA 01907 781.581.2454 date: 21 June 1999, 0830-0930 hrs REPORT of FIELD INSPECTION by: wtA/ job: 392 Essex St. Rebuild The writer inspected the site. Mr. Bailey& Mr. Slocum accompanied. 1. The third floor lintel along the D-line had its end, at location D-2, obscured by fire damage. Drawing S-2 required this damage to be removed to expose the lintel's end condition; this had been done. The lintel should be replaced with a timber or glulam of equal size and with a least 2" of bearing at each end. Mr. Slocum said this would be done. 2. Mr. Slocum pointed out a damaged and deflected timber girder in the first floor framing near the boiler room and parellel to the 2-line. The writer recommended that a cca-treated 4"x4" sill be placed on grout on the concrete foundation and a 4"x4"@16"o.c. wall be placed continously under the length of the girder. W. Bailey& W. Slocum agreed to this. 3. The writer reconfirmed, as he had at a 27 April meeting, that submittals for the specified timber connectors and any proposed material substitutions were required and subject to the Engineer's approval and that there timely procurement could control construction schedule. None have yet been received. Mr. Slocum said they would be submitted the next day. The writer agreed to pick them up at the jobsite, if required. Also, the writer explained that if non-specified connectors were obtained or locally-made it would tale additional engineering time & expense to evaluate them. 4.One of Mr. Slocum's men pointed out that some third-floor joists, between the B & C-lines, showed fresh wood where they were pulling slightly out of the 1-line wall timber. This indicates that the wall had moved outward recently. Mr. Slocum was to stabilize the wall. 5. The writer discussed, as stated on the drawings, that all means and methods of construction and stability of the structure during construction until all structural pieces are in place are the sole responsibility of the Contractor. Too, that proper fit of the structural pieces to achieve the finished building as shown on the contact drawings was the sole responsibility of the Contractor. The writer's belief is that Mr. Slocum is the Contractor because he has the ability and experience to achieve these goals. 6. Mr. Slocum said, as at the 27 April meeting, that his framing contractor wished to have a drawing with every piece of the roof framing shown. The writer stated that the drawings show every roof main member and requires these to be infilled with 2"x12"@16"o.c. which is believed clear and is know to be an accepted and standard way of depicting structural framing. Also,the roof is architecturally detailed in surfaces and the writer will meet with Mr. Slocum and his framer if desired. eC: iy0. 8w%/ry /"r. ' rl,,-- MM(r. r/lCrta ■ �1 i m 4 r m m 'a ��raE,r2h-J MEMORANDUM To: Robert Slocum Fax No.: (978) 664-3808 Slocum Construction Incorporated, General Contractors From: Daniel H. Pierce, AIAj�,y� Project: Restoration & ReconstructiToLeS-PUTNAM HOUSE 392 Essex Street, Salem, M PA Project No.: 9904 Subject:_ . CONSTRUCTION CONTROL REQUIREMENTS Date: 12 July 1999 Pursuant to our telephone conversation on July 8th, and consistent with the points I have reviewed with the Owner and Contractor on many occasions during the past several weeks, I am writing to confirm the following relative to the Submittals, Shop Drawings and other requirements of projects subject to Construction Control. With commencement of construction activities last week, I would like to clarify that as of this writing, we have not received, nor have we reviewed, the required Submittals as specified in the Contract Documents. The Contract Documents include both the Project Manual and the Drawings dated 23 April 1999. Although it is my understanding that you are in the process of assembling the required Submittals and Shop Drawings for the structural framing and framing connectors, it is at your sole risk and responsibility that you proceed with any work that requires the Architect's or Structural Engineer's review and approval of Submittals or Shop Drawings. For the record, the Project Manual includes the following language regarding the Construction LL Control requirements: Construction Control: The Massachusetts State Building Code, Article 116.0 - Registered a Architectural and Engineering Services - Construction Control provisions and requirements m apply to this Project. The Architect and Structural Engineer are required to perform the ^m following tasks: o m 1. Review; for conformance to the design concept, shop drawings, samples and other -- ------ submittals whicharesubmitted by the_Contractor,in accordance with the requirements of ?; the Contract Documents. 2. Review and approval of the quality control procedures for all code-required controlled materials. E v U) N m m rn x m W N n • Slocum Construction Incorporated 12 July 1999 Page 2 3. Be present at intervals appropriate to the stage of construction to become, generally familiar with the progress and quality of the Work and to determine, in general, if the Work is being performed in a manner consistent with the Contract Documents. Notify the Architect and authorities having jurisdiction at least thirty-six hours in advance of concealing any work. In addition, with regard to procedures, controls and the responsibilities of the Contractor, I would like to emphasize the following points that are included in the Project Manual: 1. General Contractor shall verify all dimensions, grades, and locations before proceeding with the work. Report discrepancies immediately to the Architect, for review and approval prior to commencing with the Work. 2. Contractor shall notify the Owner who shall notify the Architect of any irregularities or discrepancies discovered during demolition which may effect the current design and/or layout of the new Work, prior to commencing with the Work. 3. Remove existing materials, systems and improvements as indicated or as required to complete the Work, not scheduled or indicated for re-use, including but not limited to the following: • Remove all fire damaged materials. • Remove all wood finish flooring. • Remove all ceilings, strapping, furring and suspended framing members. • Remove all partitions not indicated to remain. • Remove all heating, plumbing and electrical materials, systems, equipment and components. All abandoned electrical & telephone conduits and wires, plumbing lines and mechanical equipment (including all anchorages and attachment devices) must be removed and properly disposed. • Remove all concrete masonry infill in existing openings of brick foundation walls where basement windows are indicated to be installed. • Remove existing floors and walls where new openings are indicated. • Remove all wood tested or observed to exhibit effects of decay or damage from water or fungal growth as determined by the structural engineer. • Remove all other materials whether specifically indicated or not, as required to complete the Work as indicated on the Drawings. 4. Shoring & Bracing: It is the Contractor's responsibility to determine the means, methods and techniques necessary to provide suitable shoring and bracing to support all concentrated and uniform loads imposed on the existing walls, partitions and other structural elements scheduled for removal as indicated on the Drawings. Provide solid timber and/or steel wide flange sections for shoring and bracing, with solid blocking as required. Maintain shoring and bracing in place until structural elements are re-braced and supported by the permanent and completed installation. Repair and replace all materials and finishes damaged during shoring and bracing. 5. Contractor: Exercise proper precaution to verify all existing conditions and layout of the Work. Contractor to notify Architect of any discrepancies immediately, and prior to commencing with the Work. • f Slocum Construction Incorporated 12 July 1999 Page 3 • Contractor is responsible for any error resulting from failure to exercise such precaution. Such error will not be considered subsequently as a basis for extra compensation. • Contractor is to lay out Work and be responsible for all lines, measurements of the building, and other Work executed under the Contract. • Contractor shall complete all cutting and patching as required to complete the Work as described in the Construction Documents. Do not cut or patch any Work in a manner that would result in the failure of the Work to perform as intended, decreased energy performance, increased maintenance, decreased operational life, or decreased safety. Do not cut structural Work without written approval from the Architect. Provide temporary shoring and bracing as necessary to support and protect the existing structure and materials during construction. Use materials identical to materials to be cut and patched. Provide finished Work which will result in equal or better than existing performance characteristics. • Should the contractor find discrepancies in or omissions from the drawings and specifications, or should he be in doubt as to their meaning, he shall at once notify the Architect and Architect prior to proceeding with the Work. The Architect has final authority with regard to the interpretation of the design intent as indicated or implied by the Contract Documents. We look forward to receiving the required Submittals and Shop Drawings in the very near future. Please submit five original copies of all Submittals and Shop Drawings, and allow five business days for our review and processing. After the Structural Engineer and ourselves have completed our review, we will return two copies to you, one for your files and one for your subcontractor or suppliers. Don't hesitate to contact me at (978) 745-3330 if you have any questions. Finally, we will be making periodic visits to the site to generally become familiar with the progress and quality of the Work, and will provide written Field Reports to record our observations, with copies to all parties. Copy: James Bailey, Owner W. Hobbs, Hobbs Endeavor Corporation Peter Strout, Salem Building Inspector Pierce Architects ,y BULLETIN Job Name: 3z/6� ���}y��� Issue Date, /P2-N/ev)/ 9!�Z Bulletin NNo J Contract:— �O� N 3f�/yfJV"` Architect's Project NO: Contractor: 6/,J 6g!vl ca�/sZ cTYa-r/ zre4,s-� Distribution: Via, /! �C3a SGacu / Ga T riT '7 - llo ����7l-QcP./T i 806;%1/�•,/- Cs'��`!"'�" I_] ❑ Proposal Request (PR): Please submit an itemized quotation for changes in the Contract Sum and/or Time incidental to proposed modifications to the Contract Documents described herein. Reference this Bulletin in the Proposal y7(�� This is not a Chanae Order nor a direction to Proceed with the work described in. �( Supplemental Instructions (SI): The Work shall be carried out in accordance with the following supplemental instructions without Change in Contract Sum or Contract Time. Prior to proceeding indicate your acceptance of these instructions for minor change to the Work as consistent with the Contract Documents and return a copy to the Architect ❑ Construction Change Directive (CCD):In order to expedite the work and avoid or minimize delays in the work which may affect the Contract Sum or Contract Time,you are requested to proceed with the referenced work promptly. Submit final costs for Work involved and change in Contract Time(if any)for inclusion in a subsequent Change Order. Not valid unless initialed by the Architect Architect's Initials Description: /T 57'C /`3�fT/ilr6 GorG/f CVs (5oa-VO Y /�,OPdV 7P GA-v eft-F ��� f3� T �ST/TGTI�+/ q� Wa4Z�' f`4� 1*?t7^Z-- 5? /U6, T/,15- /%,D/G�� �7�'GS sfS /alrti� Attachments: (List attached documents that support description) Architect: Owner: JQ.�i�G q,t� r/�/ Signature 6y the Contractor indicates the Q� r -z.� Contractor's receipt and acceptance of this U Address: �'SE�j �jr Address: G�� 5/ • Bulletin and agreement with proposed >/fA!Vfl AH [�9 ,-7Q �z � jo+ ��<9 adjustment in Contract Sum and Contract _ �t ,- r"/ r' Time,if indicated. By: e: V1 A By: _ Date: - Contractor: .151-4 C ' Second ignature for issuance as a CCD after issuance as a PR of SI: - Address: GoN5 �TYa d� iNG. By. ` l' Date: - By: Date: -el- ��� /f/ For SI and CCO only: When signed by the Owner and Architect and received by the Contractor,this document becomes By: Dale: effective immediately,and the Contractor shall proceed with the change(sl described above. d ® � ael ARGEO PAUL CELLUCCI Governor yJ pry ryp p JANESWIFT Lieutenant Governor JANE PERLOV Secretary JOSEPH S.LALLI Acting Commissioner February 12, 1999 Mark Murphy 3 Laurel Street Salem, MA 01970 RE: 392 Essex St. Salem, Third Floor Egress Dew Mr. Murphy: This letter was written in response to your inquiry as to whether the third floor of 392 Essex St., in Salem had two means of egress. On Tuesday, January 19, 1999, I met with the Salem Building Commissioner, Peter Strout, and inspected the said property. The third floor consisted of 6 dwelling units, each having I door exiting into an L shaped corridor; these doors were not of fire rated construction. At each end of the corridor there were open stairways leading to the exterior on the first floor. At the middle of the corridor there was a door splitting the corridor in half, this door was not of fire rated construction. Also, there were no exit signs at the time of the inspection The building was certified as a lodging house in 1974. The Building code in force at that time of permitting was the BOC A Pacir Rlril,rling Code oft 970 (the codel. Upon reviewing the code the following violations were found: 1. There was no enclosed independent stairway as required by Section 611.0. Section 611.0, Number of Exitways, states: There shall not be less than two (2) approved independent exitways serving every floor area above and below the first or grade floor, at least one (1) of which shall be an interior enclosed stairway... 2. There were no doors enclosing either stairway as required by Section 618.6, and Section 917. Section 618.6, Stair Exitway Doors, requires that: "All doorway opening protectives, including the frames and hardware, shall be approved self-closing swinging doors complying with article 9. Article 9, Section 917 , Fire Doors, requires stairway doors to be at least 1 % inch solid core wood doors for all residential construction. Tewksbury District Office, Dietary Building, East Street, Tewksbury, MA 01876 Phone: 978-851-9813 Fax: 978-858-0869 1 ' 1 1 1 3. There were no exit signs visible at the time of the inspection as required by Section 625.0. Section 625.0, Exit Signs and Lights, requires all means of egress to be indicated with approved metal "EXIT" signs. Additionally, The Sixth Edition of the Massachusetts State Building Code (780 CMR), the current code in force, indicates in Section 1004.2.1 Exit Order/Hazardous Means of Egress,that: In any existing building or structure not provided with exit facilities as herein prescribed for new buildings and in which the exits are deemed hazardous. or dangerous to life and limb, the building official shall declare such building dangerous and unsafe in accordance with the provisions of 780 CMR 121.0. In accordance with 780 CMR Section 1004.2.1 the following section was not provided for, and in my Opinioni.azarucas to He and lir.°.';,: Section 1006.4 Remote Location, which states: Wherever more than one exit is required from any room, space or floor of a building, such exits shall be placed as remote from each other as practicable, and shall be arranged and constructed to provide direct access in separate directions from any point in the area served so as to minimize the possibility that both exits will be blocked by any one fire or other emergency condition. In this case there was only one means of egress from within each dwelling unit. In conclusion, the BOCA Basic Building Code of 1970 required one of the stairways to be enclosed with approved materials and door construction. In addition, all means of egress were required to be marked with approved "EXIT" signs. The current building code, 780 CMR, required the said building to have two means of egress to provide direct access in separate directions from any point in the area served. None of these were provided for on the third floor of 392 Essex Street, Salem at the time of the inspection. If you have any further questions or comments please do not hesitate to call. S:rcerely, Derek J. Creaser State Building Inspector cc: Tom Rogers, DPS Peter Strout, Building Commissioner FEE-18-00 FRI 10:41 AM FIERCE ARCHITECTS FAX M0, 9787453376 F. 1 Post-Il"brand fax transmittal meo 767, aaoaDes. ARCHITECT'S OWNER D mF,a,,, FIELD REPORTt/ ARCHITECT ❑ OaCo. r CONSULTANT ❑ Dept.. Phoneg FIELD ❑ Fax _ t 3 PoxN PROJECT: FIELD REPORT N0: �I CONTRACT: �{C' .1 � `J-r ARCHITECT'S PROJECT NO: / / PAIE:—L/ 140 '"Ad ,.�� TIl�E - 1•W /�yJ WFnTHES 7✓ TEMP RANGE, CO EST Ne COMPLETION U�!"�Pl /✓ 4HEDULEI--,I �!7✓d�'�//� PRESENT AT SITE WORK'N PROCR /�'�'�/M./�_J_ tGJafwl.�fillG OBSERVATIONS L7 ow f�IYE- ,d'�i/ /�fd5'11Y�1/B7 ,Gf/ �I,L9 WprG 4Kfj`y J�J �a��'G -- t7R¢ own 44r/li'l�� / a �— _ I-NFORMATION OR ACTION REQUIRED' - j ✓/ Nf�LB�- 7�5—�YJ2T" /�r�S�fLV/N6S �F�l�//�/ AUIST�Y✓y� fM& Arch- AtWi/ /teylew6ay/. Y6� _f dc6 leCy _ Wl�ff G✓�!l�69a /�Y�'ifi 11.ts�lS/ fJ♦,/.de. i� — OC 5fi*ii�✓�, 9Y51fi�f'S' ' �-rt�s�i/ iYfJ� / fit/ :dr4s1l4G�'6 A—G - ATTACHMENT -- REPORT BY: ySd !G"rY� �rC�` � /!✓�' pa9e l of � Pages Water Graph F'�r�t�:cad j System Pressure: 63.31 PSI :80 - - Demand@-Base.- 433 GPM_..__ _...._ Flow @ Supply: 1683 GPM 70 _.-_.. ...........---- City SuPPIy @ 68 ` H drant Allowance _ _ Safety Factor -40 -- - ... - 3q 8 _.__.. - _...._._ .._.. ystem& Hose-Remand__ 122Zt45 6368 4 491 2'; 614' 736 8 859 6.' 9$2 4 1j105 2 1228 1350,8,;;; Fl wOpp" - SPRINKLER SYSTEM ANALYSIS (IMPERIAL) CALCULATION #1 Contractor : B & T Countracting 29 Juniper Drive Company Address :Saugus, MA, 01906 PAGE: 1 OF 13 DATE: 09. 12 . 1999 JOB NAME : 392 Essex Street ADDRESS : Salem, MA Description: First and Second floor Sprinklers DESIGNER : D. Smith APPROVED BY: Salem Fire Prevention CONTRACT #99034 REF. TO DRAWING #SP-1 HAZARD DESCRIPTION: NFPA13 ORDINARY HAZARD CALCULATION CRITERIA:- TOTAL AREA : 1516. 0 SQ. FT. DENSITY : 0.200 USGPM/SQ. FT. AREA/SPRINKLER : 81 . 6 SQ. FT. # OF SPRINKLER : 20 SYSTEM REQUIREMENT:- Node System Hose Hydrant Total Pressure GPM GPM GPM GPM PSI 68 433. 00 100 . 00 150. 00 683 . 00 63. 31 CITY FLOW TEST INFORMATION:- SUPPLY STATIC PRESSURE RESIDUAL PRESSURE RESIDUAL FLOW 68 75. 00 PSI 70. 00 PSI 1228 . 0 GPM FIRE PUMP RATING: PUMP PRESSURE FLOW SPRINKLER K= 5. 50 OVERHEAD PIPE C= 120 UNDERGROUND C= 140 TOTAL SAFETY = 4 . 11 PSI At Remote Head FILE: C: \FireAcad\calc\B&t7-2b.mdb SPRINKLER SYSTEM ANALYSIS -- INPUT JOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PAGE # 1 CITY FLOW TEST INFORMATION: - SUPPLY STATIC RESIDUAL FLOW HYDRANT 68 75. 00 PSI 70. 00 PSI 1228 . 0 GPM 150. 0 GPM NODE ELEV. K-FACTOR HOSE NO FT GPM ------------------------------------ 1 32 . 0 5 . 50 0. 00 2 33. 0 0 . 00 0. 00 3 33. 0 0. 00 0. 00 4 32 . 0 5 . 50 0 . 00 5 33. 0 0. 00 0. 00 6 32 . 0 0. 00 0. 00 7 32 . 0 5. 50 0. 00 8 33 . 0 0 . 00 0 . 00 9 33 . 0 0. 00 0. 00 10 32 . 0 5. 50 0. 00 11 33. 0 0. 00 0. 00 12 32 . 0 0. 00 0. 00 13 32 . 0 5. 50 0. 00 14 33 . 0 0. 00 0. 00 15 33. 0 0. 00 0. 00 16 32 . 0 5 . 50 0. 00 17 32 . 0 5. 50 0. 00 18 33 . 0 0. 00 0 . 00 19 33. 0 0. 00 0. 00 20 32 . 0 0 . 00 0. 00 21 32 . 0 5. 50 0. 00 22 33 . 0 0. 00 0 . 00 23 33. 0 0. 00 0. 00 24 32 . 0 5. 50 0 . 00 25 32 . 0 5. 50 0. 00 26 33 . 0 0 . 00 0 . 00 27 33. 0 0. 00 0 . 00 28 32. 0 0. 00 0. 00 29 34 . 0 5. 50 0 . 00 30 33. 0 0. 00 0. 00 31 33 . 0 0. 00 0. 00 32 33. 0 0. 00 0. 00 33 32 . 0 5. 50 0. 00 34 32. 0 5. 50 0. 00 35 33 . 0 0 . 00 0. 00 36 33 . 0 0. 00 0. 00 37 32. 0 0. 00 0 . 00 38 32 . 0 5. 50 0. 00 39 33. 0 0. 00 0. 00 40 32 . 0 5. 50 0. 00 41 33 . 0 0 . 00 0 . 00 42 32 . 0 5. 50 0. 00 43 33 . 0 0. 00 0. 00 JOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PAGE # 2 NODE ELEV. K-FACTOR HOSE NO FT GPM ------------------------------------ 44 33 . 0 0 . 00 0 . 00 45 33. 0 0. 00 0. 00 46 33. 0 0. 00 0 . 00 47 32. 0 0. 00 0. 00 48 32 . 0 5. 50 0 . 00 49 32 . 0 5. 50 0. 00 50 33. 0 0 . 00 0 . 00 51 33. 0 0. 00 0. 00 52 33 . 0 0 . 00 0. 00 53 32. 0 5. 50 0. 00 54 32 . 0 5 . 50 0 . 00 55 33. 0 0. 00 0. 00 56 33. 0 0. 00 0 . 00 57 32 . 0 0. 00 0. 00 58 32 . 0 0. 00 0. 00 59 32 . 0 0. 00 0. 00 60 32 . 0 0 . 00 0 . 00 61 32. 0 0. 00 0. 00 62 32 . 0 0 . 00 0 . 00 63 32 . 0 0. 00 0. 00 64 32 . 0 0. 00 0. 00 65 6. 0 0. 00 0. 00 66 3. 0 0. 00 0. 00 67 1 . 0 0. 00 100. 00 68 0. 0 0. 00 0 . 00 JOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PAGE # 3 PIPE B-N E-N DIAM. LENGTH FITT H-W-C NO NODE NODE IN. FT -------------------------------------------------------------------- 1 1 2 1 1 . 0 E 120 . 00 2 2 3 1 6. 8 T 120. 00 3 4 5 1 1 . 0 E 120 . 00 4 3 5 1 1 . 4 T 120. 00 5 3 6 1 1 . 0 T 120. 00 6 7 8 1 1 . 0 E 120. 00 7 8 9 1 6. 8 T 120. 00 8 10 11 1 1 . 0 E 120. 00 9 9 11 1 1 . 4 T 120. 00 10 9 12 1 1 . 0 T 120. 00 11 13 14 1 1 . 0 E 120. 00 12 14 15 1 11 . 2 T 120. 00 13 16 18 1 1 . 0 E 120. 00 14 17 19 1 1 . 0 T 120. 00 15 18 19 1 11 . 8 0 120. 00 16 15 19 1 0. 6 T 120. 00 17 15 20 1-1/4 1 . 0 T 120 . 00 18 21 22 1 1 . 0 E 120. 00 19 22 23 1 11 . 2 T 120 . 00 20 24 26 1 1 . 0 E 120. 00 21 25 27 1 1 . 0 T 120 . 00 22 26 27 1 11 . 8 0 120. 00 23 23 27 1 0 . 6 T 120. 00 24 23 28 1-1/4 1 . 0 T 120. 00 25 29 30 1 1 . 0 E 120. 00 26 30 31 1 1. 3 E 120. 00 27 31 32 1 2 . 7 T 120. 00 28 33 35 1 1. 0 E 120. 00 29 34 36 1 1 . 0 T 120 . 00 30 35 36 1 11 . 8 0 120. 00 31 32 36 1 0 . 6 T 120. 00 32 32 37 1-1/4 1. 0 T 120. 00 33 38 39 1 1 . 0 E 120. 00 34 39 43 1 1. 6 E 120. 00 35 40 41 1 1 . 0 E 120. 00 36 41 44 1 1 . 6 T 120. 00 37 42 45 1 1 . 0 T 120 . 00 38 43 44 1 3. 3 0 120. 00 39 44 45 1 4 . 5 0 120. 00 40 45 46 1-1/4 6. 7 E 120. 00 41 46 47 1-1/4 1 . 0 T 120. 00 42 48 50 1 1. 0 E 120. 00 43 49 51 1 1 . 0 T 120. 00 44 50 51 1 9. 3 0 120. 00 45 51 52 1 6. 8 T 120. 00 46 53 55 1 1 . 0 E 120. 00 47 54 56 1 1 . 0 T 120. 00 48 55 56 1 9. 3 0 120 . 00 49 52 56 1 2. 4 T 120. 00 JOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PAGE # 4 PIPE B-N E-N DIAM. LENGTH FITT H-W-C NO NODE NODE IN. FT -------------------------------------------------------------------- 50 52 57 1-1/2 1 . 0 T 120. 00 51 6 12 4 11. 6 0 120. 00 52 12 20 4 9. 3 0 120. 00 53 20 28 4 7 . 3 0 120. 00 54 28 37 4 7 . 3 0 120. 00 55 37 47 4 1 . 6 0 120. 00 56 47 58 4 3 . 7 E 120. 00 57 58 59 4 1 . 8 0 120. 00 58 59 60 4 6. 9 E 120. 00 59 57 60 4 3. 3 0 120. 00 60 57 61 4 35 . 0 0 120. 00 61 61 62 4 12. 0 E 120. 00 62 62 63 4 21 . 6 0 120. 00 63 63 64 4 0 . 7 E 120. 00 64 64 65 4 26. 0 ET 120. 00 65 65 66 4 5. 0 AB 120. 00 66 66 67 4 2 . 0 F 120. 00 67 67 68 4 150. 0 LTG 140. 00 ® Dt O ma $DR 61 O ca i O V O o O O � PAGE # 4 B & T Countracting 29 Juniper Drive SPRINKLER SYSTEM ANALYSIS (IMPERIAL) JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb NODE ELEVATION PRESSURE DISCHARGE WASTAGE FT. PSI GPM % ------------------------------------------------------ 1 32 . 0 16. 07 22 . 0 18 . 0 2 33. 0 16.10 3 33. 0 17 . 95 4 32. 0 16. 84 22 . 6 20. 8 5 33, 0 16. 90 6 32 . 0 21. 85 7 32 . 0 16. 07 22 . 0 18 . 0 8 33. 0 16. 11 9 33. 0 17 . 95 10 32 . 0 16. 84 22 . 6 20. 8 11 33 . 0 16. 90 12 32 . 0 21. 86 13 32 . 0 16. 62 22 . 4 31 . 6 14 33. 0 16. 67 15 33 . 0 19.29 16 32 . 0 14 . 59 21 . 0 23. 3 17 32 . 0 15 . 79 21 . 9 27 . 5 18 33. 0 14 .58 19 33 . 0 16.28 20 32 . 0 21. 88 21 32 . 0 16. 65 22. 4 31 . 6 22 33. 0 16. 70 23 33. 0 19. 33 24 32. 0 14 . 62 21 . 0 23. 3 25 32 . 0 15 . 82 21 . 9 27 . 5 26 33. 0 14 . 61 27 33 . 0 16. 31 28 32. 0 21 . 92 29 34 . 0 16. 71 22 . 5 31 . 2 30 33. 0 17 . 63 31 33 . 0 18 . 16 32 33. 0 19. 41 33 32 . 0 14 . 68 21 . 1 23 . 7 34 32. 0 15 . 88 21 . 9 27. 9 35 33 . 0 14 . 68 36 33. 0 16. 38 37 32 . 0 22 . 01 38 32 . 0 13. 70 20. 4 19. 5 39 33 . 0 13 . 67 40 32 . 0 13. 74 20. 4 19. 7 41 33. 0 13 . 71 42 32 . 0 16.28 22 .2 30. 3 43 33 . 0 14 . 16 44 33. 0 14 . 60 45 33 . 0 16. 80 46 33. 0 19. 59 J FF : T ti Y 4n i \�F 1...............�R......................... PAGE # 4 B & T Countractinq 29 Juniper Drive SPRINKLER SYSTEM ANALYSIS (IMPERIAL) JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-2 .mdb NODE ELEVATION PRESSURE DISCHARGE WASTAGE FT. PSI GPM % ------------------------------------------------------ 1 34 . 0 11 . 10 13. 0 99. 5 2 34 . 0 11 . 31 13. 1 96.2 3 35. 0 10. 83 4 35. 0 11. 22 5 35 . 0 11 . 80 6 34 . 5 13. 17 7 34 . 0 11 .22 13 . 1 100 . 5 8 34 . 0 11 . 42 13. 2 97 .2 9 35. 0 10. 95 10 35. 0 11 . 34 11 35. 0 11 . 90 12 34 . 5 13.28 13 34 . 5 13. 75 14 34 . 5 14 . 91 15 34 . 5 15. 19 16 34 . 5 15. 40 17 6. 0 28 . 68 18 3. 0 30. 02 19 1 . 0 31 . 04 100 . 0 HOSE 20 0. 0 32 . 42 150. 0 HOSE PAGE # 5 J'OB NAME: 392 Essex Street ' FILE: C: \FireAcad\calc\B&t7-1-2 .mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 1 QN=13. 0 L=1 . 0 PT=11 . 10 K=3 . 90 1 D=1 . 109 F=2 . 6 0. 045 PF=0. 16 V=4 . 32 FT=E PE=-0. 43 C=120. 00 3 QP=13. 0 LT=3 . 6 PT=10. 83 Pv=0. 13 ------------------------------------------------------------------------------ 2 QN=13. 1 L=1 . 0 PT=11 . 31 K=3. 90 2 D=1 . 109 F=6. 6 0 . 046 PF=0 . 35 V=4 . 36 FT=T PE=-0. 43 C=120. 00 4 QP=13. 1 LT=7 . 6 PT=11 .22 Pv=0 . 13 ------------------------------------------------------------------------------ 3 QN=0. 0 L=8 . 7 PT=10 . 83 K=0 . 00 3 D=1. 109 F=0. 0 0. 045 PF=0 . 39 V=4 . 32 FT=O PE=0 . 00 C=120 . 00 4 QP=13 . 0 LT=8 . 7 PT=11 .22 Pv=0. 13 ------------------------------------------------------------------------------ 4 QN=0. 0 L=0. 9 PT=11 .22 K=0. 00 4 D=1 . 109 F=2 . 6 0. 164 PF=0 . 58 V=8 . 67 FT=E PE=0. 00 C=120. 00 5 QP=26. 1 LT=3. 5 PT=11. 80 Pv=0. 51 ------------------------------------------------------------------------------ 5 QN=0. 0 L=0. 5 PT=11. 80 K=0. 00 5 D=1 . 109 F=6. 6 0. 164 PF=1 . 15 V=8 . 67 FT=T PE=0. 22 C=120. 00 6 QP=26. 1 LT=7 . 1 PT=13 . 17 Pv=0 . 51 ------------------------------------------------------------------------------ 7 QN=13 . 1 L=1 . 0 PT=11 . 22 K=3. 90 6 D=1 . 109 F=2 . 6 0. 045 PF=0. 16 V=4 . 34 FT=E PE=-0 . 43 C=120. 00 9 QP=13. 1 LT=3. 6 PT=10. 95 Pv=0. 13 ------------------------------------------------------------------------------ 8 QN=13. 2 L=1 . 0 PT=11 . 42 K=3. 90 7 D=1 . 109 F=6. 6 0 . 046 PF=0 . 35 V=4 . 38 FT=T PE=-0. 43 C=120. 00 10 QP=13 . 2 LT=7 . 6 PT=11 . 34 Pv=0 . 13 ------------------------------------------------------------------------------ 9 QN=0. 0 L=8 . 7 PT=10. 95 K=0 . 00 8 D=1. 109 F=0. 0 0. 045 PF=0. 39 V=4 . 34 FT=O PE=0 . 00 C=120 . 00 10 QP=13. 1 LT=8 . 7 PT=11. 34 Pv=0. 13 ------------------------------------------------------------------------------ 10 QN=0. 0 L=0. 8 PT=11 . 34 K=0 . 00 9 D=1 . 109 F=2 . 6 0. 165 PF=0. 56 V=8 . 72 FT=E PE=0. 00 C=120 . 00 11 QP=26. 3 LT=3. 4 PT=11 . 90 Pv=0. 51 ------------------------------------------------------------------------------ 11 QN=0. 0 L=0 . 5 PT=11 . 90 K=0. 00 10 D=1 . 109 F=6. 6 0. 165 PF=1 . 17 V=8 . 72 FT=T PE=0. 22 C=120. 00 12 QP=26. 3 LT=7 . 1 PT=13 .28 Pv=0 . 51 ------------------------------------------------------------------------------ PAGE # 6 JDB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-2 .mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 6 QN=0 . 0 L=7 . 7 PT=13 . 17 K=0. 00 11 D=2 . 067 F=6. 6 0. 008 PF=0 . 11 V=2 . 50 FT=O PE=0. 00 C=120. 00 12 QP=26. 1 LT=14 . 3 PT=13.28 Pv=0. 04 ------------------------------------------------------------------------------ 12 QN=0. 0 L=9. 8 PT=13 .28 K=0. 00 12 D=2 . 067 F=6 . 6 0. 029 PF=0. 47 V=5 . 01 FT=T PE=0. 00 C=120. 00 13 QP=52 . 4 LT=16. 4 PT=13 . 75 Pv=0 . 17 ------------------------------------------------------------------------------ 13 QN=0. 0 L=34 . 1 PT=13 . 75 K=0 . 00 13 D=2 . 067 F=6. 6 0. 029 PF=1. 16 V=5. 01 FT=TT PE=0. 00 C=120 . 00 14 QP=52 . 4 LT=40 . 6 PT=14 . 91 Pv=0. 17 ------------------------------------------------------------------------------ 14 QN=0. 0 L=3.2 PT=14 . 91 K=0. 00 14 D=2 . 067 F=6. 6 0 . 029 PF=0 .28 V=5 . 01 FT=E PE=0 . 00 C=120. 00 15 QP=52 . 4 LT=9. 8 PT=15. 19 Pv=0. 17 ------------------------------------------------------------------------------ 15 QN=0. 0 L=0. 8 PT=15. 19 K=0. 00 15 D=2 . 067 F=6. 6 0. 029 PF=0 . 21 V=5. 01 FT=E PE=0. 00 C=120. 00 16 QP=52 . 4 LT=7 . 4 PT=15. 40 Pv=0. 17 ------------------------------------------------------------------------------ 16 QN=0. 0 L=26. 0 PT=15. 40 K=0. 00 16 D=2 . 067 F=6. 6 0. 029 PF=0. 93 V=5. 01 FT=ET PE=12 . 35 C=120 . 00 17 QP=52 . 4 LT=32 . 6 PT=28 . 68 Pv=0. 17 ------------------------------------------------------------------------------ 17 QN=0. 0 L=5. 0 PT=28 . 68 K=0. 00 17 D=4 . 026 F=29. 0 0. 001 PF=0. 04 V=1 . 32 FT=AB PE=1 . 30 C=120. 00 18 QP=52 . 4 LT=34 . 0 PT=30. 02 Pv=0. 01 ------------------------------------------------------------------------------ 18 QN=0. 0 L=2 . 0 PT=30 . 02 K=0. 00 18 D=4 . 026 F=140. 0 0 . 001 PF=0. 16 V=1. 32 FT=F PE=0. 87 C=120 . 00 19 QP=52. 4 LT=142 . 0 PT=31. 04 Pv=0. 01 ------------------------------------------------------------------------------ 19 QN=100. 0 L=150. 0 PT=31 . 04 K=0 . 00 19 D=4 .220 F=46. 8 0. 005 PF=0 . 95 V=3. 50 FT=LTG PE=0 . 43 C=140. 00 20 QP=152. 4 LT=196. 8 PT=32. 42 Pv=0. 08 ------------------------------------------------------------------------------ PAGE # 7 � r LEGEND S = Standard 45 degree elbow QN = Normal flow discharge E = Standard 90 degree elbow QP = Flow; in; pipe L = Long turn degree elbow D = Pipe inside diameter T = Standard tee L = Pipe length B = Butterfly valve F = Fitting equivalence G = Gate valve FT = Fitting type C = Check valve LT = Total length A = Alarm valve PT = Total node pressure D = Dry pipe valve PF = Pressure friction loss W = Deluge valve PE = Pressure elevation loss P = Pre-action valve K = Sprinkler K-factor F = Back flow preventer V = Velocity F, x = Constant pressure x in PSI C = C-factor for fitting F PV = Velocity pressure -------------------------------------------------------------------- SIGNIFICANT HYDRAULICAL NOTES: Maximum velocity of 8 . 72 FT/SEC at pipe 9 Most remote sprinkler @ node 1 ..................... FireAcad ., . .......... System Pressure: 32.42 PSI Demand (P-Base 52-37 GPM. Flow Supply: 302.37 GPM ?fl @ 20 city Sup.pk . .......... ..................... ......................... 'Safety Factor ............................... ............... ............. 0 W: ........................... . .... .............................. .............................-.......... ......-.......... ------ Hydrant Allowance 30 ................... ............ ----------------- ------------- -- ------ ........------------------ _System A_Hose demand .............- 10- ............. -- --------- --- - ---------..........- .......... 1228#5 6368 4 491 2 4 14052 1128- 1350 ............. :JOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-2 .mdb PAGE # 2 PIPE B-N E-N DIAM. LENGTH FITT H-W-C NO NODE NODE IN. FT ------------------------------------- ------------------------------ 1 1 3 1 1 . 0 E 120. 00 2 2 4 1 1 . 0 T 120. 00 3 3 4 1 8 . 7 0 120. 00 4 4 5 1 0. 9 E 120. 00 5 5 6 1 0, 5 T 120. 00 6 7 9 1 1 . 0 E 120. 00 7 8 10 1 1 . 0 T 120. 00 8 9 10 1 8. 7 0 120. 00 9 10 11 1 0. 8 E 120 . 00 10 11 12 1 0. 5 T 120. 00 11 6 12 1-1/2 7 . 7 0 120. 00 12 12 13 1-1/2 9. 8 T 120. 00 13 13 14 1-1/2 34 . 1 TT 120. 00 14 14 15 1-1/2 3.2 E 120. 00 15 15 16 1-1/2 0 . 8 E 120 . 00 16 16 17 4 26. 0 ET 120. 00 17 17 18 4 5 . 0 AB 120 . 00 18 18 19 4 2 . 0 F 120. 00 19 19 20 4 150. 0 LTG 140. 00 SPRINKLER SYSTEM ANALYSIS -- INPUT JOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-2 .mdb PAGE # 1 CITY FLOW TEST INFORMATION: - SUPPLY STATIC RESIDUAL FLOW HYDRANT 20 75. 00 PSI 70. 00 PSI 1228 . 0 GPM 150. 0 GPM NODE ELEV. K-FACTOR HOSE NO FT GPM ------------------------------------ 1 34 . 0 3 . 90 0. 00 2 34 . 0 3. 90 0 . 00 3 35 . 0 0. 00 0. 00 4 35 . 0 0 . 00 0 . 00 5 35. 0 0. 00 0. 00 6 34 . 5 0. 00 0 . 00 7 34 . 0 3. 90 0. 00 8 34 . 0 3 . 90 0 . 00 9 35. 0 0. 00 0. 00 10 35 . 0 0 . 00 0 . 00 11 35. 0 0. 00 0. 00 12 34 . 5 0 . 00 0 . 00 13 34 . 5 0. 00 0. 00 14 34 . 5 0 . 00 0 . 00 15 34 . 5 0. 00 0. 00 16 34 . 5 0 . 00 0 . 00 17 6. 0 0. 00 0. 00 18 3 . 0 0. 00 0. 00 19 1 . 0 0. 00 100. 00 20 0. 0 0. 00 0 . 00 /. SPRINKLER SYSTEM ANALYSIS (IMPERIAL) CALCULATION #2 Contractor : B & T Countracting 29 Juniper Drive Company Address:Saugus, MA, 01906 PAGE: 1 OF 7 DATE: 09. 11 . 1999 JOB NAME : 392 Essex Street ADDRESS : Salem, MA Description:Sprinklers DESIGNER : D. Smith APPROVED BY: Salem Fire Prevention CONTRACT #99034 REF. TO DRAWING #SP-1 HAZARD DESCRIPTION: NFPA13-R FOUR HEADS FLOWING CALCULATION CRITERIA:- TOTAL AREA : 0. 0 SQ. FT. DENSITY : 0. 100 USGPM/SQ. FT. AREA/SPRINKLER : 66. 8 SQ. FT. # OF SPRINKLER : 4 SYSTEM REQUIREMENT: - Node System Hose Hydrant Total Pressure GPM GPM GPM GPM PSI 20 52 . 37 100. 00 150. 00 302 . 37 32 . 42 CITY FLOW TEST INFORMATION:- SUPPLY STATIC PRESSURE RESIDUAL PRESSURE RESIDUAL FLOW 20 75. 00 PSI 70. 00 PSI 1228 . 0 GPM FIRE PUMP RATING: PUMP PRESSURE FLOW SPRINKLER K= 3. 90 OVERHEAD PIPE C= 120 UNDERGROUND C= 140 TOTAL SAFETY = 32 . 21 PSI Below Supply FILE: C: \FireAcad\calc\B&t7-1-2.mdb 'y TSU tow7, 11`��C�oti 4'x4' P.T. newel post, provide decorative caps A owners rciue5t Ile �• �„ 7.� I I I I I I I I I I I I I I I I I I I I •I I I I I I I I I I I 5/4'x6' P.T. decking, typ. P.T. ballu5ter5 E I 8 iik, Aiy%V� A4 / 10' 5onotwbc On 12"x24' free-form "Dell' footing C,wl� ITI, vT5 = (ty . For 3) n � Lam" A3 a s " 9 00 4°x4° P.T. newel post, . Provide decorative cape owners req eet PnAKEM A IP.T. ballusters o rails, -t p/of,—SAEW fe v 5/4'x6' P.T. decking, typ. A3 3q�s� =�T �4E1/�EIGG� ro/ZL�a�o z� ��� //$f�1�f�� J SPRINKLER SYSTEM ANALYSIS (IMPERIAL) CALCULATION #1 Contractor : B & T Countracting 29 Juniper Drive Company Address:Saugus, MA, 01906 PAGE: 1 OF 7 DATE: 09. 11. 1999 JOB NAME : 392 Essex Street ADDRESS : Salem, MA Description:Sprinklers DESIGNER : D. Smith APPROVED BY: Salem Fire Prevention CONTRACT #99034 REF. TO DRAWING #SP-1 HAZARD DESCRIPTION: NFPA13-R ONE HEAD FLOWING CALCULATION CRITERIA:- TOTAL AREA : 65 . 0 SQ. FT. DENSITY : 0. 100 USGPM/SQ. FT. AREA/SPRINKLER : 57 . 3 SQ. FT. # OF SPRINKLER : 1 SYSTEM REQUIREMENT: - Node System Hose Hydrant Total Pressure GPM GPM GPM GPM PSI 14 22. 55 100. 00 150 . 00 272 . 55 37 . 16 CITY FLOW TEST INFORMATION: - SUPPLY STATIC PRESSURE RESIDUAL PRESSURE RESIDUAL FLOW 14 75. 00 PSI 70. 00 PSI 1228 . 0 GPM FIRE PUMP RATING: PUMP PRESSURE FLOW SPRINKLER K= 5 . 50 OVERHEAD PIPE C= 120 UNDERGROUND C= 140 TOTAL SAFETY = 27 . 53 PSI Below Supply FILE: C: \FireAcad\calc\B&t7-1-1 .mdb i SPRINKLER SYSTEM ANALYSIS -- INPUT JOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-l .mdb PAGE # 1 CITY FLOW TEST INFORMATION: - SUPPLY STATIC RESIDUAL FLOW HYDRANT 14 75. 00 PSI 70. 00 PSI 1228 . 0 GPM 150. 0 GPM NODE ELEV. K-FACTOR HOSE NO FT GPM --------------------- 1 34 . 0 5. 50 0. 00 2 35. 0 0. 00 0. 00 3 35. 0 0. 00 0. 00 4 35 . 0 0. 00 0. 00 5 35. 0 0. 00 0.00 6 34 . 5 0. 00 0. 00 7 34 . 5 0. 00 0. 00 8 34 . 5 0. 00 0. 00 9 34 . 5 0. 00 0. 00 10 34 . 5 0 . 00 0. 00 11 6. 0 0. 00 0. 00 12 3. 0 0 . 00 0. 00 13 1 . 0 0. 00 100. 00 14 0. 0 0. 00 0. 00 SOB NAME : 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-1 .mdb PAGE # 2 PIPE B-N E-N DIAM. LENGTH FITT H-W-C NO NODE NODE IN. FT -------------------------------------------------------------------- 1 1 2 1 1 . 0 E 120. 00 2 2 3 1 3. 2 E 120. 00 3 3 4 1 5 . 4 0 120. 00 4 4 5 1 6. 1 E 120. 00 5 5 6 1 0. 5 T 120. 00 6 6 7 1-1/2 19.2 T 120. 00 7 7 8 1-1/2 34 . 1 TT 120. 00 8 8 9 1-1/2 3 .2 E 120. 00 9 9 10 1-1/2 0. 8 E 120. 00 10 10 11 4 100. 0 ET 120. 00 11 11 12 4 5. 0 AB 120. 00 12 12 13 4 2. 0 F 120. 00 13 13 14 4 150 . 0 LTG 140 . 00 VA 2M �y4k \ : : PAGE # 4 ' I B & T Countracting 29 Juniper Drive SPRINKLER SYSTEM ANALYSIS ( IMPERIAL) JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-l .mdb NODE ELEVATION PRESSURE DISCHARGE WASTAGE FT. PSI GPM % ------------------------------------------------------ 1 34 . 0 16 . 80 22 . 5 293 . 3 2 35. 0 16. 82 3 35 . 0 17 . 54 4 35. 0 18 .22 5 35 . 0 19. 31 6 34 . 5 20. 40 7 34 . 5 20 . 56 8 34 . 5 20. 80 9 34 . 5 20. 86 10 34 .5 20. 91 11 6. 0 33 . 89 12 3 . 0 35.20 13 1 . 0 36. 10 100 . 0 HOSE 14 0. 0 37 . 16 150. 0 HOSE PAGE # 5 JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-l .mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 1 QN=22 . 5 L=1 . 0 PT=16: 80 K=5 . 50 1 D=1 . 109 F=2. 6 0. 125 PF=0. 45 V=7 . 49 FT=E PE=-0 . 43 C=120 . 00 2 QP=22. 5 LT=3. 6 PT=16. 82 Pv=0. 38 ------------------------------------------------------------------------------ 2 QN=0. 0 L=3. 2 PT=16. 82 K=0. 00 2 D=1 . 109 F=2 . 6 0. 125 PF=0 . 73 V=7 . 49 FT=E PE=0. 00 C=120. 00 3 QP=22 . 5 LT=5. 8 PT=17 . 54 Pv=0 . 38 ------------------------------------------------------------------------------ 3 QN=0. 0 L=5 . 4 PT=17 . 54 K=0 . 00 3 D=1. 109 F=0. 0 0. 125 PF=0 . 68 V=7 . 49 FT=O PE=0 . 00 C=120. 00 4 QP=22. 5 LT=5. 4 PT=18 . 22 Pv=0. 38 ------------------------------------------------------------------------------ 4 QN=0. 0 L=6. 1 PT=18 . 22 K=0. 00 4 D=1 . 109 F=2 . 6 0 . 125 PF=1 . 09 V=7 . 49 FT=E PE=0. 00 C=120. 00 5 QP=22. 5 LT=8 . 7 PT=19. 31 Pv=0. 38 ------------------------------------------------------------------------------ 5 QN=0. 0 L=0. 5 PT=19.31 K=0 . 00 5 D=1 . 109 F=6. 6 0. 125 PF=0 . 88 V=7 . 49 FT=T PE=0.22 C=120. 00 6 QP=22 . 5 LT=7 . 1 PT=20. 40 Pv=0 . 38 ------------------------------------------------------------------------------ 6 QN=0 . 0 L=19. 2 PT=20 . 40 K=0. 00 6 D=2. 067 F=6. 6 0.006 PF=0. 15 V=2. 16 FT=T PE=0 . 00 C=120 .00 7 QP=22. 5 LT=25. 8 PT=20. 56 Pv=0 . 03 ------------------------------------------------------------------------------ 7 QN=0. 0 L=34 . 1 PT=20.56 K=0. 00 7 D=2 . 067 F=6. 6 0. 006 PF=0 . 24 V=2 . 16 FT=TT PE=0. 00 C=120. 00 8 QP=22 . 5 LT=40. 6 PT=20. 80 Pv=0 . 03 ------------------------------------------------------------------------------ 8 QN=0 . 0 L=3.2 PT=20 . 80 K=0 . 00 8 D=2 . 067 F=6. 6 0. 006 PF=0. 06 V=2. 16 FT=E PE=0 . 00 C=120. 00 9 QP=22.5 LT=9. 8 PT=20. 86 Pv=0. 03 ------------------------------------------------------------------------------ 9 QN=0 . 0 L=0. 8 PT=20 . 86 K=0 . 00 9 D=2 . 067 F=6. 6 0. 006 PF=0. 04 V=2. 16 FT=E PE=0. 00 C=120. 00 10 QP=22. 5 LT=7 . 4 PT=20. 91 Pv=0. 03 ------------------------------------------------------------------------------ 10 QN=0. 0 L=100. 0 PT=20. 91 K=0. 00 10 D=2 . 067 F=6. 6 0. 006 PF=0 . 64 V=2 . 16 FT=ET PE=12 . 35 C=120. 00 11 QP=22 . 5 LT=106. 6 PT=33 . 89 Pv=0 . 03 ------------------------------------------------------------------------------ PAGE # 6 JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-1-l .mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT . PSI/FT. PSI ------------------------------------------------------------------------------ 11 QN=0 . 0 L=5 . 0 PT=33 . 89 K=0. 00 11 D=4 . 026 F=29. 0 0. 000 PF=0 . 01 V=0. 57 FT=AB PE=1 . 30 C=120 . 00 12 QP=22 . 5 LT=34 . 0 PT=35.20 Pv=0. 00 ------------------------------------------------------------------------------ 12 QN=0. 0 L=2 . 0 PT=35. 20 K=0. 00 12 D=4 . 026 F=140. 0 0 . 000 PF=0. 03 V=0 . 57 FT=F PE=0. 87 C=120. 00 13 QP=22 . 5 LT=142 . 0 PT=36. 10 Pv=0 . 00 ------------------------------------------------------------------------------ 13 QN=100 . 0 L=150. 0 PT=36 . 10 K=0 . 00 13 D=4 .220 F=46. 8 0. 003 PF=0. 63 V=2. 81 FT=LTG PE=0. 43 C=140. 00 14 QP=122 . 5 LT=196. 8 PT=37 . 16 Pv=0. 05 ------------------------------------------------------------------------------ PAGE 4 7 1 LEGEND S = Standard 45 degree elbow QN = Normal flow discharge E = Standard 90 degree elbow QP = Flow; in; pipe L = Long turn degree elbow D = Pipe inside diameter T = Standard tee L = Pipe length B = Butterfly valve F = Fitting equivalence G = Gate valve FT = Fitting type C = Check valve LT = Total length A = Alarm valve PT = Total node pressure D = Dry pipe valve PF = Pressure friction loss W = Deluge valve PE = Pressure elevation loss P = Pre-action valve K = Sprinkler K-factor F = Back flow preventer V = Velocity F, x = Constant pressure x in PSI C = C-factor for fitting F PV = Velocity pressure -------------------------------------------------------------------- SIGNIFICANT HYDRAULICAL NOTES : Maximum velocity of 7 . 49 FT/SEC at pipe 5 Most remote sprinkler @ node 1 Water Graph ............ 0 System Pressure: 37.16 PSI ......---- - -- ......---- ......."Demand(gg-Base. -22-.55-GPM Flow Q Supply: 272.55 GPM ----------- — ......... ------------­-- ...... .......... ...... ------I _ ___*CKSupp1y@j4 . Safety Factor .............. .......... --------- --- - ................... ........ .......... ....................... ........ Hydrant Allowance -- ------------- ----- - -- ------ --- ....... ........ .......... System &Hose dehiand ------ ................... --------------- ------ ------.................. �U�z "Mn 0� 1222145 6365 4 491 2 814: 736 8 859 6;' S82,4 1105 2 ........ .. ......1350 8 . .......... ................... Ti PAGE # 5 NODE ELEVATION PRESSURE DISCHARGE WASTAGE FT. PSI GPM % ------------------------------------------------------ 47 32 . 0 22 . 04 48 32. 0 13 . 58 20 . 3 43. 4 49 32 . 0 14 . 38 20 . 9 27 . 8 50 33. 0 13.55 51 33 . 0 14 . 79 52 33. 0 20. 68 53 32. 0 15 . 20 21 . 4 33 . 6 54 32. 0 16. 09 22 . 1 35.2 55 33 . 0 15 . 22 56 33. 0 16. 60 57 32. 0 23. 23 58 32. 0 22 . 52 59 32 . 0 22 . 57 60 32. 0 23. 14 61 32 . 0 24 . 71 62 32 . 0 25. 77 63 32 . 0 26. 68 64 32. 0 27 .27 65 6. 0 41 . 31 66 3. 0 44 . 50 67 1 . 0 53 . 26 100. 0 HOSE 68 0. 0 63 . 31 150. 0 HOSE PAGE # 6 - JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 1 QN=22 . 0 L=1 . 0 PT=16. 07 K=5. 50 1 D=1. 049 F=2. 0 0. 157 PF=0. 47 V=8 . 19 FT=E PE=-0 . 43 C=120. 00 2 QP=22. 1 LT=3. 0 PT=16. 10 Pv=0. 45 ------------------------------------------------------------------------------ 2 QN=0. 0 L=6. 8 PT=16. 10 K=0. 00 2 D=1 . 049 F=5. 0 0. 157 PF=1 . 84 V=8 . 19 FT=T PE=0. 00 C=120. 00 3 QP=22 . 1 LT=11 . 8 PT=17 . 95 Pv=0. 45 ------------------------------------------------------------------------------ 4 QN=22 . 6 L=1 . 0 PT=16. 84 K=5. 50 3 D=1 . 049 F=2 . 0 0. 164 PF=0 . 49 V=8 . 38 FT=E PE=-0 . 43 C=120 . 00 5 QP=22 . 6 LT=3. 0 PT=16. 90 Pv=0. 47 ------------------------------------------------------------------------------ 3 QN=0. 0 L=1 . 4 PT=16. 90 K=0. 00 4 D=1 . 049 F=5 . 0 0. 164 PF=1 . 05 V=8 . 38 FT=T PE=0 . 00 C=120 . 00 5 QP=22 . 6 LT=6. 4 PT=17 . 95 Pv=0. 47 ------------------------------------------------------------------------------ 3 QN=0. 0 L=1 . 0 PT=17 . 95 K=0. 00 5 D=1 . 049 F=5 . 0 0. 578 PF=3 . 47 V=16. 57 FT=T PE=0. 43 C=120. 00 6 QP=44 . 6 LT=6. 0 PT=21 . 85 Pv=1 . 85 ------------------------------------------------------------------------------ 7 QN=22 . 0 L=1 . 0 PT=16 . 07 K=5 . 50 6 D=1. 049 F=2 . 0 0. 157 PF=0. 47 V=8 . 19 FT=E PE=-0 . 43 C=120 . 00 8 QP=22 . 1 LT=3. 0 PT=16. 11 Pv=0 . 45 ------------------------------------------------------------------------------ 8 QN=0. 0 L=6. 8 PT=16. 11 K=0 . 00 7 D=1 . 049 F=5 . 0 0 . 157 PF=1 . 84 V=8 . 19 FT=T PE=0. 00 C=120. 00 9 QP=22 . 1 LT=11 . 8 PT=17 . 95 Pv=0. 45 ------------------------------------------------------------------------------ 10 QN=22 . 6 L=1 . 0 PT=16. 84 K=5. 50 8 D=1. 049 F=2 . 0 0. 164 PF=0. 49 V=8 . 38 FT=E PE=-0. 43 C=120. 00 11 QP=22. 6 LT=3. 0 PT=16. 90 Pv=0. 47 ------------------------------------------------------------------------------ 9 QN=0. 0 L=1 . 4 PT=16. 90 K=0 . 00 9 D=1 . 049 F=5 . 0 0. 164 PF=1 . 05 V=8 . 38 FT=T PE=0. 00 C=120. 00 11 QP=22 . 6 LT=6. 4 PT=17 . 95 Pv=0 . 47 ------------------------------------------------------------------------------ 9 QN=0. 0 L=1 . 0 PT=17 . 95 K=0. 00 10 D=1. 049 F=5. 0 0.579 PF=3 . 47 V=16. 57 FT=T PE=0 . 43 C=120 . 00 12 QP=44 . 6 LT=6. 0 PT=21 . 86 Pv=1 . 85 ------------------------------------------------------------------------------ PAGE * 7 JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 13 QN=22 . 4 L=1 . 0 PT=16. 62 K=5 . 50 11 D=1 . 049 F=2 . 0 0. 162 PF=0. 49 V=8.33 FT=E PE=-0 . 43 C=120 . 00 14 QP=22 . 4 LT=3 . 0 PT=16. 67 Pv=0. 47 ------------------------------------------------------------------------------ 14 QN=0. 0 L=11 .2 PT=16. 67 K=0. 00 12 D=1 . 049 F=5. 0 0. 162 PF=2 . 62 V=8 . 33 FT=T PE=0. 00 C=120. 00 15 QP=22 . 4 LT=16.2 PT=19. 29 Pv=0 . 47 ------------------------------------------------------------------------------ 16 QN=21 . 0 L=1 . 0 PT=14 . 59 K=5. 50 13 D=1. 049 F=2. 0 0. 143 PF=0. 43 V=7 . 80 FT=E PE=-0. 43 C=120 . 00 18 QP=21 . 0 LT=3. 0 PT=14 . 58 Pv=0. 41 ------------------------------------------------------------------------------ 17 QN=21 . 9 L=1 . 0 PT=15. 79 K=5 . 50 14 D=1 . 049 F=5. 0 0. 154 PF=0. 93 V=8 . 11 FT=T PE=-0 . 43 C=120 . 00 19 QP=21 . 9 LT=6. 0 PT=16. 28 Pv=0. 44 ------------------------------------------------------------------------------ 18 QN=0. 0 L=11 . 8 PT=14 . 58 K=0 . 00 15 D=1 . 049 F=0 . 0 0 . 143 PF=1 . 70 V=7 . 80 FT=O PE=0. 00 C=120. 00 19 QP=21 . 0 LT=11 . 8 PT=16. 28 Pv=0 . 41 ------------------------------------------------------------------------------ 15 QN=0 . 0 L=0 . 6 PT=16.28 K=0. 00 16 D=1 . 049 F=5. 0 0.537 PF=3. 01 V=15. 91 FT=T PE=0. 00 C=120 . 00 19 QP=42. 9 LT=5. 6 PT=19.29 Pv=1 . 70 ------------------------------------------------------------------------------ 15 QN=0. 0 L=1. 0 PT=19.29 K=0. 00 17 D=1 . 380 F=6. 0 0. 308 PF=2 . 15 V=14 . 01 FT=T PE=0. 43 C=120. 00 20 QP=65. 3 LT=7 . 0 PT=21 . 88 Pv=1 . 32 ------------------------------------------------------------------------------ 21 QN=22 . 4 L=1 . 0 PT=16. 65 K=5 . 50 18 D=1 . 049 F=2 . 0 0. 162 PF=0. 49 V=8 . 33 FT=E PE=-0 . 43 C=120. 00 22 QP=22 . 4 LT=3. 0 PT=16. 70 Pv=0 . 47 ------------------------------------------------------------------------------ 22 QN=0. 0 L=11 . 2 PT=16. 70 K=0 . 00 19 D=1 . 049 F=5. 0 0. 162 PF=2 . 63 V=8 . 33 FT=T PE=0 . 00 C=120. 00 23 QP=22. 4 LT=16. 2 PT=19. 33 Pv=0. 47 -------------------- --------------------------------------------------------- 24 QN=21 . 0 L=1 . 0 PT=14 . 62 K=5. 50 20 D=1 . 049 F=2 . 0 0. 144 PF=0 . 43 V=7 . 81 FT=E PE=-0. 43 C=120. 00 26 QP=21 . 0 LT=3 . 0 PT=14 . 61 Pv=0 . 41 ------------------------------------------------------------------------------ PAGE # 8 JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 25 QN=21 . 9 L=1 . 0 PT=15 . 82 K=5 . 50 21 D=1 . 049 F=5. 0 0. 155 PF=0. 93 V=8 . 12 FT=T PE=-0. 43 C=120. 00 27 QP=21. 9 LT=6. 0 PT=16. 31 Pv=0. 44 ------------------------------------------------------------------------------ 26 QN=0. 0 L=11 . 8 PT=14 . 61 K=0 . 00 22 D=1 . 049 F=0 . 0 0 . 144 PF=1 . 70 V=7 . 81 FT=O PE=0. 00 C=120. 00 27 QP=21 . 0 LT=11 . 8 PT=16. 31 Pv=0 . 41 ------------------------------------------------------------------------------ 23 QN=0 . 0 L=0 . 6 PT=16. 31 K=0. 00 23 D=1 . 049 F=5. 0 0. 538 PF=3. 02 V=15. 93 FT=T PE=0 . 00 C=120. 00 27 QP=42 . 9 LT=5. 6 PT=19. 33 Pv=1 . 71 ------------------------------------------------------------------------------ 23 QN=0. 0 L=1 . 0 PT=19. 33 K=0. 00 24 D=1 . 380 F=6 . 0 0 . 308 PF=2 . 16 V=14 . 02 FT=T PE=0. 43 C=120. 00 28 QP=65 . 4 LT=7 . 0 PT=21 . 92 Pv=1 . 32 ------------------------------------------------------------------------------ 29 QN=22 . 5 L=1 . 0 PT=16. 71 K=5 . 50 25 D=1 . 049 F=2 . 0 0. 163 PF=0. 49 V=8 . 35 FT=E PE=0 . 43 C=120 . 00 30 QP=22. 5 LT=3. 0 PT=17 . 63 Pv=0. 47 ------------------------------------------------------------------------------ 30 QN=0. 0 L=1 . 3 PT=17 . 63 K=0 . 00 26 D=1 . 049 F=2 . 0 0. 163 PF=0 . 53 V=8 . 35 FT=E PE=0. 00 C=120. 00 31 QP=22 . 5 LT=3 . 3 PT=18 . 16 Pv=0. 47 ------------------------------------------------------------------------------ 31 QN=0. 0 L=2 . 7 PT=18 . 16 K=0. 00 27 D=1 . 049 F=5. 0 0. 163 PF=1 .25 V=8 . 35 FT=T PE=0. 00 C=120 . 00 32 QP=22. 5 LT=7 . 7 PT=19. 41 Pv=0. 47 ------------------------------------------------------------------------------ 33 QN=21 . 1 L=1 . 0 PT=14 . 68 K=5. 50 28 D=1 . 049 F=2 . 0 0. 144 PF=0. 43 V=7 . 82 FT=E PE=-0.43 C=120. 00 35 QP=21 . 1 LT=3. 0 PT=14 . 68 Pv=0. 41 ------------------------------------------------------------------------------ 34 QN=21 . 9 L=1 . 0 PT=15 . 88 K=5. 50 29 D=1 . 049 F=5 . 0 0 . 155 PF=0. 93 V=8 . 14 FT=T PE=-0. 43 C=120. 00 36 QP=21 . 9 LT=6. 0 PT=16. 38 Pv=0. 45 ----------------------------------------------------------------------------- 35 QN=0. 0 L=11 . 8 PT=14 . 68 K=0. 00 30 D=1 . 049 F=0. 0 0. 144 PF=1 . 71 V=7 . 82 FT=O PE=0 . 00 C=120. 00 36 QP=21 . 1 LT=11 . 8 PT=16. 38 Pv=0. 41 ------------------------------------------------------------------------------ JOB NAME: 392 Essex Street PAGE # 9 FILE: C: \FireAcad\calc\B&t7-2b.mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 32 QN=0 . 0 L=0. 6 PT=16. 38 K=0. 00 31 D=1. 049 F=5. 0 0. 540 PF=3. 03 V=15. 96 FT=T PE=0 . 00 C=120 . 00 36 QP=43. 0 LT=5. 6 PT=19. 41 Pv=1 . 71 ------------------------------------------------------------------------------ 32 QN=0. 0 L=1 . 0 PT=19. 41 K=0 . 00 32 D=1 . 380 F=6. 0 0. 309 PF=2 . 17 V=14 . 05 FT=T PE=0. 43 C=120. 00 37 QP=65 . 5 LT=7 . 0 PT=22 . 01 Pv=1 . 33 ------------------------------------------------------------------------------ 38 QN=20 . 4 L=1 . 0 PT=13. 70 K=5. 50 33 D=1 . 049 F=2 . 0 0. 135 PF=0. 41 V=7. 56 FT=E PE=-0. 43 C=120 . 00 39 QP=20. 4 LT=3. 0 PT=13. 67 Pv=0. 38 ------------------------------------------------------------------------------ 39 QN=0. 0 L=1 . 6 PT=13. 67 K=0. 00 34 D=1 . 049 F=2 . 0 0. 135 PF=0 . 49 V=7 . 56 FT=E PE=0. 00 C=120. 00 43 QP=20. 4 LT=3. 6 PT=14 . 16 Pv=0. 38 ------------------------------------------------------------------------------ 40 QN=20. 4 L=1 . 0 PT=13 . 74 K=5. 50 35 D=1 . 049 F=2 . 0 0. 136 PF=0. 41 V=7 . 57 FT=E PE=-0. 43 C=120. 00 41 QP=20 . 4 LT=3 . 0 PT=13 . 71 Pv=0 . 39 ------------------------------------------------------------------------------ 41 QN=0 . 0 L=1 . 6 PT=13 . 71 K=0. 00 36 D=1 . 049 F=5. 0 0. 136 PF=0. 89 V=7 . 57 FT=T PE=0. 00 C=120 . 00 44 QP=20. 4 LT=6. 6 PT=14 . 60 Pv=0. 39 ------------------------------------------------------------------------------ 42 QN=22 . 2 L=1 . 0 PT=16.28 K=5. 50 37 D=1 . 049 F=5 . 0 0 . 159 PF=0. 95 V=8 . 24 FT=T PE=-0. 43 C=120. 00 45 QP=22 .2 LT=6. 0 PT=16. 80 Pv=0 . 46 ------------------------------------------------------------------------------ 43 QN=0. 0 L=3 . 3 PT=14 . 16 K=0 . 00 38 D=1 . 049 F=0. 0 0. 135 PF=0. 45 V=7.56 FT=O PE=0. 00 C=120. 00 44 QP=20. 4 LT=3. 3 PT=14 . 60 Pv=0. 38 ------------------------------------------------------------------------------ 44 QN=0. 0 L=4 . 5 PT=14 . 60 K=0 . 00 39 D=1 . 049 F=0. 0 0. 489 PF=2 . 19 V=15. 13 FT=O PE=0 . 00 C=120 . 00 45 QP=40. 8 LT=4 . 5 PT=16. 80 Pv=1 . 54 ------------------------------------------------------------------------------ 45 QN=0. 0 L=6. 7 PT=16. 80 K=0. 00 40 D=1 . 380 F=3 . 0 0.288 PF=2 . 80 V=13. 50 FT=E PE=0. 00 C=120. 00 46 QP=63 . 0 LT=9. 7 PT=19. 59 Pv=1 . 23 ------------------------------------------------------------------------------ • JOB NAME: 392 Essex Street PAGE # 10 FILE: C: \FireAcad\calc\B&t7-2b.mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 46 QN=0 . 0 L=1 . 0 PT=19. 59 K=0. 00 41 D=1. 380 F=6. 0 0. 288 PF=2 . 01 V=13. 50 FT=T PE=0. 43 C=120 . 00 47 QP=63 . 0 LT=7 . 0 PT=22. 04 Pv=1 . 23 ------------------------------------------------------------------------------ 48 QN=20. 3 L=1. 0 PT=13. 58 K=5 . 50 42 D=1 . 049 F=2 . 0 0. 134 PF=0 . 40 V=7 . 53 FT=E PE=-0. 43 C=120. 00 50 QP=20. 3 LT=3 . 0 PT=13 . 55 Pv=0 . 38 ------------------------------------------------------------------------------ 49 QN=20. 9 L=1 . 0 PT=14 . 38 K=5 . 50 43 D=1 . 049 F=5. 0 0. 141 PF=0. 85 V=7 . 74 FT=T PE=-0 . 43 C=120 . 00 51 QP=20. 9 LT=6. 0 PT=14 . 79 Pv=0. 40 ------------------------------------------------------------------------------ 50 QN=0. 0 L=9. 3 PT=13. 55 K=0. 00 44 D=1 . 049 F=0. 0 0 . 134 PF=1 .24 V=7 . 53 FT=O PE=0. 00 C=120. 00 51 QP=20 . 3 LT=9. 3 PT=14 . 79 Pv=0. 38 ------------------------------------------------------------------------------ 51 QN=0. 0 L=6. 8 PT=14 . 79 K=0. 00 45 D=1 . 049 F=5 . 0 0. 497 PF=5. 89 V=15.27 FT=T PE=0 . 00 C=120 . 00 52 QP=41 . 1 LT=11 . 8 PT=20. 68 Pv=1 . 57 ------------------------------------------------------- ---------------------- 53 QN=21. 4 L=1. 0 PT=15.20 K=5. 50 46 D=1 . 049 F=2 . 0 0 . 149 PF=0 . 45 V=7 . 96 FT=E PE=-0 . 43 C=120. 00 55 QP=21 . 5 LT=3 . 0 PT=15 . 22 Pv=0 . 43 ------------------------------------------------------------------------------ 54 QN=22 . 1 L=1 . 0 PT=16. 09 K=5 . 50 47 D=1 . 049 F=5. 0 0. 157 PF=0. 94 V=8 . 19 FT=T PE=-0 . 43 C=120. 00 56 QP=22 . 1 LT=6. 0 PT=16. 60 Pv=0. 45 ------------------------------------------------------------------------------ 55 QN=0. 0 L=9. 3 PT=15. 22 K=0 . 00 48 D=1 . 049 F=0 . 0 0 . 149 PF=1 . 38 V=7 . 96 FT=O PE=0. 00 C=120. 00 56 QP=21 . 5 LT=9. 3 PT=16. 60 Pv=0 . 43 ------------------------------------------------------------------------------ 52 QN=0 . 0 L=2 . 4 PT=16. 60 K=0 . 00 49 D=1 . 049 F=5. 0 0. 552 PF=4 . 09 V=16. 16 FT=T PE=0 . 00 C=120. 00 56 QP=43. 5 LT=7 . 4 PT=20. 68 Pv=1 . 76 -------`---------------------------------------------------------------------- 52 QN=0. 0 L=1. 0 PT=20. 68 K=0. 00 50 D=1. 610 F=8 . 0 0. 235 PF=2 . 11 V=13. 34 FT=T PE=0. 43 C=120. 00 57 QP=84 . 7 LT=9. 0 PT=23 . 23 Pv=1 .20 ------------------------------------------------------------------------------ JOB NAME: 392 Essex Street PAGE # 11 FILE: C: \FireAcad\calc\B&t7-2b.mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 6 QN=0. 0 L=11 . 6 PT=21 . 85 K=0 . 00 51 D=4 . 260 F=0. 0 0. 001 PF=0. 01 V=1 . 00 FT=O PE=0. 00 C=120. 00 12 QP=44 . 6 LT=11 . 6 PT=21 . 86 Pv=0. 01 ------------------------------------------------------------------------------ 12 QN=0. 0 L=9. 3 PT=21 . 86 K=0. 00 52 D=4 . 260 F=0. 0 0. 002 PF=0. 02 V=2 . 01 FT=O PE=0. 00 C=120. 00 20 QP=89. 3 LT=9. 3 PT=21 . 88 Pv=0 . 03 ------------------------------------------------------------------------------ 20 QN=0. 0 L=7 . 3 PT=21 . 88 K=0. 00 53 D=4 .260 F=0. 0 0. 006 PF=0. 05 V=3. 48 FT=O PE=0 . 00 C=120 . 00 28 QP=154 . 6 LT=7 . 3 PT=21 . 92 Pv=0. 08 ------------------------------------------------------------------------------ 28 QN=0. 0 L=7 . 3 PT=21 . 92 K=0. 00 54 D=4 . 260 F=0 . 0 0. 012 PF=0 . 09 V=4 . 95 FT=O PE=0. 00 C=120. 00 37 QP=219. 9 LT=7 . 3 PT=22 . 01 Pv=0 . 16 ------------------------------------------------------------------------------ 37 QN=0. 0 L=1 . 6 PT=22 . 01 K=0 . 00 55 D=4 .260 F=0. 0 0. 020 PF=0. 03 V=6. 42 FT=O PE=0 . 00 C=120. 00 47 QP=285. 4 LT=1. 6 PT=22. 04 Pv=0. 28 ------------------------------------------------------------------------------ 47 QN=0. 0 L=3. 7 PT=22. 04 K=0. 00 56 D=4 .260 F=13. 2 0 . 028 PF=0 . 48 V=7 . 84 FT=E PE=0. 00 C=120. 00 58 QP=348 . 4 LT=16. 9 PT=22. 52 Pv=0 . 41 ------------------------------------------------------------------------------ 58 QN=0 . 0 L=1 . 8 PT=22 . 52 K=0 . 00 57 D=4 .260 F=0. 0 0. 028 PF=0. 05 V=7. 84 FT=O PE=0 . 00 C=120 . 00 59 QP=348 . 4 LT=1 . 8 PT=22 . 57 Pv=0. 41 ------------------------------------------------------------------------------ 59 QN=0. 0 L=6. 9 PT=22. 57 K=0 . 00 58 D=4 . 260 F=13 . 2 0. 028 PF=0. 57 V=7 . 84 FT=E PE=0. 00 C=120. 00 60 QP=348 . 4 LT=20 . 1 PT=23. 14 Pv=0. 41 ------------------------------------------------------------------------------ 57 QN=0 . 0 L=3 . 3 PT=23 . 14 K=0 . 00 59 D=4 . 260 F=0 . 0 0. 028 PF=0 . 09 V=7 . 84 FT=O PE=0. 00 C=120. 00 60 QP=348 . 4 LT=3. 3 PT=23 . 23 Pv=0. 41 ------------------------------------------------------------------------------ 57 QN=0 . 0 L=35 . 0 PT=23 .23 K=0 . 00 60 D=4 .260 F=0. 0 0. 042 PF=1 . 48 V=9. 75 FT=O PE=0. 00 C=120 . 00 61 QP=433. 0 LT=35. 0 PT=24 . 71 Pv=0. 64 ------------------------------------------------------------------------------ PAGE # 12 - JOB NAME: 392 Essex Street FILE: C: \FireAcad\calc\B&t7-2b.mdb PIPE NODE FLOW DIA. LENGTH FRICTION PRESSURE No. No. GPM IN. FT. PSI/FT. PSI ------------------------------------------------------------------------------ 61 QN=0. 0 L=12. 0 PT=24 . 71 K=0. 00 61 D=4 .260 F=13.2 0. 042 PF=1. 07 V=9. 75 FT=E PE=0 . 00 C=120 . 00 62 QP=433. 0 LT=25. 2 PT=25. 77 Pv=0. 64 ------------------------------------------------------------------------------ 62 QN=0. 0 L=21 . 6 PT=25. 77 K=0. 00 62 D=4 . 260 F=0 . 0 0. 042 PF=0 . 91 V=9. 75 FT=O PE=0. 00 C=120. 00 63 QP=433 . 0 LT=21 . 6 PT=26. 68 Pv=0. 64 ------------------------------------------------------------------------------ 63 QN=0 . 0 L=0. 7 PT=26. 68 K=0 . 00 63 D=4 .260 F=13.2 0 . 042 PF=0. 59 V=9. 75 FT=E PE=0. 00 C=120. 00 64 QP=433. 0 LT=13 . 9 PT=27 .27 Pv=0. 64 ------------------------------------------------------------------------------ 64 QN=0. 0 L=26. 0 PT=27 .27 K=0. 00 64 D=4 . 260 F=39. 6 0 . 042 PF=2 . 77 V=9 . 75 FT=ET PE=11 .27 C=120. 00 65 QP=433 . 0 LT=65. 6 PT=41 . 31 Pv=0. 64 ------------------------------------------------------------------------------ 65 QN=0. 0 L=5. 0 PT=41 . 31 K=0. 00 65 D=4 . 026 F=29. 0 0. 056 PF=1 . 89 V=10. 91 FT=AB PE=1.30 C=120. 00 66 QP=433 . 0 LT=34 . 0 PT=44 . 50 Pv=0 . 80 ------------------------------------------------------------------------------ 66 QN=0. 0 L=2. 0 PT=44 . 50 K=0. 00 66 D=4 . 026 F=140. 0 0 . 056 PF=7 . 90 V=10. 91 FT=F PE=0 . 87 C=120 . 00 67 QP=433. 0 LT=142 . 0 PT=53.26 Pv=0 . 80 ------------------------------------------------------------------------------ 67 QN=100. 0 L=150. 0 PT=53. 26 K=0. 00 67 D=4 . 220 F=46. 8 0. 049 PF=9 . 62 V=12 . 23 FT=LTG PE=0. 43 C=140. 00 68 QP=533. 0 LT=196. 8 PT=63 . 31 Pv=1 . 01 ------------------------------------------------------------------------------ PAGE # 13 LEGEND S = Standard 45 degree elbow QN = Normal flow discharge E = Standard 90 degree elbow QP = Flow; in; pipe L = Long turn degree elbow D = Pipe inside diameter T = Standard tee L = Pipe length B = Butterfly valve F = Fitting equivalence G = Gate valve FT = Fitting type C = Check valve LT = Total length A = Alarm valve PT = Total node pressure D = Dry pipe valve PF = Pressure friction loss W = Deluge valve PE = Pressure elevation loss P = Pre-action valve K = Sprinkler K-factor F = Back flow preventer V = Velocity F, x = Constant pressure x in PSI C = C-factor for fitting F PV = Velocity pressure SIGNIPTCANT HYDPAOLICAL NOTES: Maximum velocity of 16. 55 FT/SEC at pipe I0 Most remote sprinkler @ node 38 - JAN-27-00 THU 110:21 AM PIERCE ARCHITECTS FAX N0, 9787453376 P. 1 L FACSIMILE TRANSMITTAL Date- ?7-� Proiact- ,rte, -- ® biect: _ FAX Number From: ���1�49*f2G TEL Number, Pages: _ llr� Icd luding Cover Sheet COMMENTS: tl 14. � /40Y 0 0 9 b Copy: Lynn -JAN-27-00 TEU 10:22 AM PIERCE ARCHITiCTQ PAX IND. 97874"376 F, 2 ARCHITECT'S OWNER ■ FIELD REPORT ARCHITECTo CONSULTANT ■ FIELD ■ -CONTRACT: / 41"~ ARCHITECT'S PROJECT NO:- •. ;// TIME 4"o-4W"llJE8 5&!!W4 RANGE `/ i� L' 9 •r .: 3 /ice efd2v, i " a✓ ,i rales el" /1 i�� r !_ �_ - moi• L�� .��- I INFQBMATION OR ACTION REQUIRED � � w ATTACHtOrNTS REPORT !moi 9 MxP- 2-99 TUU 6:20 PM PIERCE ARCHITECTS FAX N0, 4797450376 P. L J J / • � 1 t 2 March 1999 F. Kelley Landolphi Attorney and Counselor at Law 70 Washington Street Suite 401 Salem, MA 01970 Reference: Reconstruction and Repairs to 392 Essex Street in Salem, MA Dear Attorney Landolphi: As requested, I am pleased to provide the following update of our progress to date with completion of design services for the reconstruction and repairs to 392 Essex Street in Salem. As you know, we have inspected the building's conditions following the fire and clean-up operations with the structural engineer, the owner, and the owner's contractors with the objective of defining the scope of the project, the timetable and the estimated construction costs for completion of the repairs and reconstruction work. With regard to the status of our architectural services, we arc currently in the early phases of the developing the design and approvals process. Our first priority will be to complete the drawings necessary to make the building wealhertight by reconstructing the roof and damaged exterior walls, windows and doors. Once we have completed the desigu services associated with the weathertight shell scope of work, we will confirm the scope of interior renovations necessary to bring the building into compliance with applicable codes and standards. N The building is a three story wood frame structure with a two story addition off the rear et. It was built in 1850/1851 in the imposing Italianate style as a single family residence, clearly intended to reflect the prominence of its owner, a successful printer-publisher. The gross floor area of the LL building will be confirmed very shortly upon completion of our existing conditions documentation, o and is expected to range between 10,000 and 11,000 square feet in area. The building housed a total of 19 rental units ranging in size from studio apartments to two bedroom units. Although we are still in the early stages of the design process, and no final decisions m have been made as of yet, the nature and scope of the renovations required to rebuild the portions o of the building damaged by fire is expected to yield a reduction in the number of apartment units m from the pre-fire total of 19, to a post construction total of approximately 16 units. This will be accomplished by reducing the number of studio apartments, thereby increasing the percentage of g one and two bedroom apartments. It is my expectation that as a result of the improvements to be t made to the building, that the monthly rental rates and gross income will increase. It is also my understanding that the rental income is anticipated to range from between $550 and $750 per month per apartment unit, yielding an anticipated total projected monthly income of approximately $9500. £ m X w N r 03-02-99 19 :22 RECEIVED FROM:9787453376 P. 02 MRP,- 2-99 TUE 6:21 PM PIERCE ARCHITECTS FAX N0, 9737453376 F', 392 Essex Street 2 March 1999 Page 2 With regard to the estimated timetable and construction costs for completion of this project, my experience as an architect specializing in historic building renovations tells me that a realistic budget for completion of the work as described will likely fall in the range of$400,000 to $450,000, and that the project should be able to he completed within 9 months. I would like to point out however, that since the first and second floors of the rear el were not effected by the fire and remain structurally intact, and since the rear two story addition remains completely undamaged in any way by fire or water, it is very likely that a portion of the building can be completed and ready for occupancy within 6 months. I trust that the foregoing addresses your questions. However, if you need additional information or if I can be of any further assistance, please do not hesitate to contact me. Respectfully, PIERCE ARCHITECTS 6le1 H. Pierce, AIA Principal 03-02-99 19 : 23 RECEIVED FROM:9757453376 P. 03 KBEN CONSTRUCTION 29 Whipple Rd. Billerica Ma.01821 U.S.A. Phone 508-667-2446 Fax 508-667-2446 November 04, 1999 Peter Strout Public Property Department Salem,Ma. Peter, I wish to inform you that as of November 5, 1999 the contract to do the remodeling work at 392 Essex St. Salem Ma. (Permit 9698-1999)has been terminated, As of this date the work completed by me has been limited to exterior trim and finish only. At this time I would like to have my name(Alden Consruction),License,liability and all references to me removed from the above permit. Thank u, James Alden i5 ,PEQ'� .3 Gcl� �f/l/G,7,�G , ig • t o r Fx4' P.T. newel post,' ,rovide decorative caps owners request • I I I I I I I I I I 5/4'x6' P.T. decking, typ. P.T. MIu5ter5 I IO' 5onotu6e On 12°x24' free—form °Bell' footing 1 (t`y. For 3) a s ' g eo 4'x4' P.T. newel post, . Provide decorative cape K, w owners req est Ij P"59 in v" M •�, 3s8 vim/ O:01VO- ' rail -✓/MGP :9 7 5/4'x6' P.T. decking, typ. Z,� A3 t A4141_77 1�`��Cgroti 4'x4' P.T. newel post,' provide decorative caps W� owners request I I I I I I • I I I I I I I I I I I I I I LL1J-LL1J_LL 5/4'x6' P.T. decking, typ. P.T. Mlusters Br CgG£c-. I A4 10' 5onotube On III x24' free-form 'sell' footing fty�4f:or 3) t&q /<x/_9 7 ,e"ad.�Ea l 6 �ir6 i�� G A3 �W- A 'e ' g eo 4'x4' P.T. newel post,. ;rovide decorative caps owners req ,A Al v� I I I I 1 1. 1 -KO 7 R � A P.T. ballu5ter-5o 17 f/Y a 5/4'x6' P.T. decking, typ. 4'-0' rA 3) STATEMENT OF PROJECT COMPLETION ARCHITECTURAL DESIGN Date: 29 September 2000 To: Thomas St. Pierre, Assistant Building Inspector City of Salem Building Department One Salem Green Salem, MA 01970 From: Daniel H. Pierce, AIA Pierce Architects 214 Derby Street, Salem, MA Project: RESTORATION & RECONSTRUCTION OF THE IVES-PUTNAM HOUSE 392 ESSEX STREET, SALEM, MA I visited the construction site during the building permit application process, and/or sent other appropriately qualified design professionals, and determined to the extent possible that the work was generally completed in accordance with the Contract Documents prepared by Pierce Architects as submitted with the building permit application, and that the work was done in accordance with the applicable provisions of the Massachusetts State Building Code. 29 September 2000 Srgn e: Date gWSD ARcy�T 9c, o No. 01 m m ;0 SALEM, MA Pq MPS Daniel H. Pierce, AIA 6401 Architect: Mass. Reg. No. Thomas St. Pierre, Assistant Building Inspector 30 August 2000 Page 2 Third Floor Unit 15 will be ready for occupancy only after the Design/Build Sprinkler Contractor has adjusted the deflector at sidewall sprinkler head such that the deflector is positioned parallel with the ceiling plane above. We will provide you with a copy of our Field Report that outlines our observations and findings regarding the remedial repairs and additional work required to complete the project within the next 30 days. Our Field Report will be sent to you under separate cover immediately upon its completion. If you have any questions in the interim, please do not hesitate to contact me. 30 August 2000 i ature: Date: gtEFED G\ =Sc 'Pz cc e � No.6401 m SALEM, w o MA �J5 4 Daniel H. Pierce, AIA 6401 Architect: Mass. Reg. No. copy: James Bailey -49 James A Bailey 81 Essex Street Salem,MA 01970 Tel(978)745-0685 September 21,2000 B&T Contracting 29 Juniper Drive Saugus,MA 01906 ATTN: Fred Toomey Dear Mr Toomey, As we discussed on 9/20/00 I have requested your letter of compliance as required in a letter dated September 6,2000 from Pierce Architects. It is stated in the aforementioned correspondence from Pierce on page 5 "Please give the DBC(Design/Build Contractor)a copy of this letter and inform him that before a final sign-off and acceptance of the sprinkler system can be approved,fully tested and ready for"final inspection."and 4 copies of the"As-Built Drawings"including hydraulic calculations as indicated herein." I have called Pierce Architects for this final inspection as the work has been completed. However,Pierce Architects requires that you supply me with this"letter of compliance"as stated on page 5. Please contact me via telephone upon receipt of this letter in order that we may make arrangements for you to supply me with this letter. It might be helpful if you could fax this letter directly to Pierce Architects as well. Their fax#is(978)745-3376. on for your coo ration in this matter, l J r s A Baileys / O cc Pierce Architects .co r n �C)�11N6 Salem Historical Commission ONE SALEM GREEN, SALEM,MASSACHUSETTS 01970 (978)745-9595 EXT.311 FAX(978)740-0404 May 6, 1999 To Whom It May Concern: The Salem Historical Commission has reviewed the plans dated April 23, 1999 for the reconstruction of the fire damaged house at 392 Essex Street and finds that the work proposed is substantially similar in exterior design to the building prior to the fire and therefore is excluded from the review by the Commission as provided in the Salem Historical Commission Ordinance Section 5.6.4. Sincerely, THE SALEM HISTORICAL COMMISSION Helen Sides Chair r' Sir'/�'� •- �. :,�..�:��,-/�y/ F - 4;1 �� � r .� ��2E� � `� �S 7nulc7cmmonwea& of i'�/ab5achu6ellj 7-10-02 SUBPOENA v TO. KEEPER OF RECORDS O BLDG. DEPT. CITY OF SALEM, CITY HALL ANNEX 120 WASHINGTON STREET SALEM,M A. 9 � � �� '� _ J �- ___ �, A � I �,� .-� � \