266 CANAL STREET POOL PLAN REVIEW LETTER CITY OF SALEM, MASSACHUSETTS - -n..r- BOARD OF HEALTH 98 WASHINGTON STREET,3RD FLOOR SALEM,MA 01970 TEL. (978)741-1800 DOMINICK PANGALLO health a'salem.com DAVID GItEENBAUM,RS,CHO MAYOR HEA_TH AGENT June 10, 2025 Keith Mulkern Aquaknot Pools,Inc. 55 Woodrock Road Weymouth, MA 02189 Dear Mr. Mulkern, After having the plans relating to the pool being built for the Residences at Canal St., 266 Canal Street; Salem, MA reviewed, in accordance with 105 CMR 435.00: Minimum Standards for Swimming Pools (State Sanitary Code: Chapter 5)the following observations have been made: 435.03.5. There is no notation for a hose bib out by the pool. This may not be in your scope of work, but not seeing one on the Landscape drawing means a hose bib may not be placed out by the pool. There must be a hose bib in the vicinity of the pool. 435.03.7. There must be a designated space for janitorial supplies (also this space may be used for pool equipment, chemical storage, etc.). 435.03.8. The fencing is called out to be compliant, but no other information(cut sheet, spec sheet, etc.) is provided. This must be provided to both the Building and Health Departments for review and approval prior to installation. 435.06.3. There must be an extra set of cartridges. These should be part of the pool contractors, scope, if not, they must be provided by the owners before final inspection. 435.09. The drawing and the autofill cut sheet show the make-up water going directly into the pool. There must be an air gap. There should not be a problem with using a backflow preventer, but the code does specifically call out an air gap. A variance may be needed for this system. 435.12.2. There must be a 4" stripe on the edges of the steps. The 2" on the run and 2" on the riser works best. 435.13.1. There must be a 4' walkway around the pool. There appears to be 4' around the side opposite the building, but I could not scale this out to be sure-just a point to confirm before construction. 435.22. There is no signage called out. This is usually supplied by the pool contractor. If so, this should be noted on the plans someplace. If not, signage compliant with 435.22-3 must be supplied before inspection. 435.24. The Landscape drawing indicates there will be ring buoy, rescue hook and `backboard'. A backboard is only required in pools with lifeguards. If there are no lifeguards at this pool (and there are no notes that there will be guards) a backboard is not required and should not be supplied. 435.25.L There must be a first aid kit. This should be part of the pool contractors, scope, if not, it must be provided by the owners before final inspection. An ANSI- Z-308.1-2015 is recommended. These are not expensive and readily available. 435.30.1. There must be a test kit. This should be part of the pool contractors, scope, if not, it must be provided by the owners before final inspection. A Taylor K-2006 is recommended. These are not expensive and readily available. Please provide written responses and updated plans to reflect how these questions/comments will be addressed. Please feel free to contact me should you have any questions or need additional information. Sincerel J1� KKJ avid Greenbaum Health Agent Outlook Re: Plans From David Greenbaum <dgreenbaum@Salem.com> Date Tue 6/24/2025 2:20 PM To Keith Mulkern <keith@aquaknotpools.com> Cc Steve Mullen <steve@aquaknotpools.com> Hi Keith, Please see responses to your email below in red. Feel free to reach out if you have any other questions. Best, David David Greenbaum, RS, CHO Health Agent Salem Board of Health 98 Washington Street, 3rd Floor Salem, MA 01970 Phone - 978-619-5650 Office — 978-741-1800 From: Keith Mulkern <keith@aquaknotpools.com> Sent:Thursday, June 19, 2025 11:23 AM To: David Greenbaum <dgreenbaum@salem.com> Cc: Steve Mullen <steve@aquaknotpools.com> Subject: Re: Plans Caution: This email originated from outside our system. Please do not click links or open attachments unless you recognize the sender and know the content is safe. Hi David, See below and attached information. 435.03.5 - Hose Bib is on P-11 which I have attached. This is ok. 435.03.7 - Janitorial supplies will be stored in the same room as pool equipment. This is ok. 435.03.8 - See cut sheet attached. As mentioned, this must be provided to the Building Department prior to installation for review. 435.06.3 - Confirming there will be a second set of cartridges on site per code. This is ok. 435.09 - This is typical how we have done the auto fills connected to a backflow preventor. Please let me know how we need to proceed on this one. This is ok per the Board of Health, however this will need approval from Engineering and DPW. 435.12.2 - We do have the 4" stripe on the tread per code. Please confirm if you would like to be on rise as well. This is ok. 435.13.1 - Please see the attached plan with dimensions. This is ok. 435.22 - Owner will have three (3) made - one for each of the bathrooms, as well as outside next to the shower. They will also have one for no lifeguards (attached). We do supply as a generic on as part of our contract. This is ok. 435.24 - We have passed this on to the owner. This is ok. 435.25.1 - We will provide a first aid kit made per the spec in the health code. 435.30.1 - We provide a test. Same one you mentioned, TTK2006 - FAS DPD Test Kit. Please let me know of the few items we need to confirm. Thank you, Keith Mulkern On Wed, Jun 11, 2025 at 3:10PM David Greenbaum <-Igreenbaum<<<�salem.cUn.> wrote: Good Afternoon Keith, Attached is a letter with comments/questions from the pool plan review for the Residences at Canal. Please feel free to let me know if you have any questions. David David Greenbaum, RS, CHO Health Agent Salem Board of Health 98 Washington Street, 3rd Floor Salem, MA 01970 Phone - 978-619-5650 Office—978-741-1800 From: Keith Mulkern <keith aquaknotpools.com> Sent:Thursday, May 22, 2025 4:58 PM To: David Greenbaum <dgreenbaumPsalem.com> Subject: Re: Plans Caution: This email originated from outside our system. Please do not click links or open attachments unless you recognize the sender and know the content is safe. No problem. See attached. Let me know if you need anything further. Thank you On Thu, May 22, 2025 at 3:59 PM David Greenbaum < eenbaumiLcIsaiem.com> wrote: Good Afternoon Keith, My apologies, I realize I will need a second set of plans. Could you send them to me electronically at this email address? Thank you, David David Greenbaum, RS, CHO Health Agent Salem Board of Health 98 Washington Street, 3rd Floor Salem, MA 01970 Phone - 978-619-5650 Office—978-741-1800 „ ' q uaknot POOLS, INC. Keith Mulkem 'ill�''-*_ 781.335.7705 1 fax 781.331 3391 55 Woodw*Road 1 Weymouth.MA 02189 R"Oaquaknotpools.com I AquaknolPools. Nationwide Aquatic Consulting, Inc. N AC, Inc. 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-35941518-494-4045 5/27/2025 David Greenbaum, RS, CHO Health Agent- Salem Board of Health 98 Washington St. Salem, MA 01970 David, Courses of action- broken down by responsible party (probably) Notes- For items 435-03-5, 7, 8 and 13-1. You could call the Architect and ask for responses to these questions (or call the pool contractor and have them make the inquiries). For items 436-06-h-3; -12-2; -22; -24; 25-1 and -30-1 1 would advise a call to the pool contractor to get settled what is in the pool contractors' scope and what is expected to be supplied by the Owner so there is time to get any necessary equipment or schedule any work (the stripe on the steps) before the project goes any farther. For 435-09. The City Plumbing Inspector should be contacted to find out if he/she is OK with a backflow preventer instead of an air gap. Arch itect- 435-03-5. There is no notation for a hose bib out be the pool. This is most probably not in the pool contractors' scope of work, but not seeing one on the Landscape drawing means a hose bib may not be placed out by the pool. There must be one in the vicinity of the pool. -7. There must be a designated space for janitorial supplies (also this space may be used for pool equipment, chemical storage, etc.). -8. The fencing is called out to be compliant, but no other information (cut sheet, spec sheet, etc.) is provided. This should be reviewed and approved before installation. -13-1. There must be a 4' walk way around the pool. There appears to be 4' around the side opposite the building, but I could not scale this out to be sure- just a point to confirm before construction. 1 Nationwide Aquatic Consulting, Inc. NAC, Inc. 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594/ 518-494-4045 5/27/2025 David Greenbaum, RS, CHO Health Agent- Salem Board of Health 98 Washington St. Salem, MA 01970 David, Courses of action- in order of Health Code requirements N otes- 435-03-5. There is no notation for a hose bib out be the pool. This is most probably not in the pool contractors' scope of work, but not seeing one on the Landscape drawing means a hose bib may not be placed out by the pool. There must be one in the vicinity of the pool. -7. There must be a designated space for janitorial supplies (also this space may be used for pool equipment, chemical storage, etc.). -8. The fencing is called out to be compliant, but no other information (cut sheet, spec sheet, etc.) is provided. This should be reviewed and approved before installation. -06-h. See 435-30-1. -3. There must be an extra set of cartridges. These should be part of the pool contractors, scope, if not, they must be provided by the owners before final inspection. -09. The drawing and the autofill cut sheet show the make-up water going directly into the pool. There must be an air gap. There should not be a problem with using a backflow preventer, but the code does specifically call out an air gap. A variance may be needed for this system. -12-2. There must be a 4" stripe on the edges of the steps. The 2" on the run and 2" on the riser works best. -13-1. There must be a 4' walk way around the pool. There appears to be 4' around the side opposite the building, but I could not scale this out to be sure- just a point to confirm before construction. -22. There is no signage called out. This is usually supplied by the pool 1 1 Nationwide Aquatic Consulting, Inc. I\lAC, Inc 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594/ 518-494-4045 Facility .Checklist- MA Health Code Compliance© N1= Not Inspected; NA= Not Applicable Section: 435.02 Design approval- Has plans, approved by MA Registered Professional Engineer or Registered Architect, been submitted to Local Board of Health? /N Date Not Dated Has design been approved? /N By whom NAC Date: 5/27/25 Have changes been submitted? Y /N Date on going Approved? Y /N By whom Date: Has Board of Health been notified one week prior to pool opening? Y /N Date—NA Scheduled Health Dept. inspection date: 435.03 1). Adequate dressing rooms? Cross trafficking? _ NA 2). Showers- 1/40 Bathers Y/N NA 3). Toilets- Females 1/40 Y/N NA Males 1/40 (113 urinals) Y/N NA 4). Washbasin- 1/60 bathers (in vicinity of toilets) Y/N NA 5). Hose connections for flushing dressing rooms. YIN _ See Notes 6). Room for sick/injured Y/N (blanket Y/N) NA 7). Storage space-janitorial supplies/instruction equipment- See Notes _ 8). Lighting- Pool OK . Deck OV Bathhouse/toilet areas NA 9). Heating units clear Y/N 10). Ventilation of showers/toilet areas NA 11). Acoustical properties (for lifeguards) _ NA 12). b- fence- up to five feet- board or stockade _ See Notes Six feet or over- chain link Self latching gate- four feet above ground Nationwide Aquatic Consulting, Inc. NAC, Inc• 2 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594 / 518-494-4045 Facility Checklist- MA Health Code Compliance© No openings wider than three inches c- barrier for indoor pools 4' high gate not wider than 3", self-latching gate — 13). Drinking water (bubbler) NA 14). a- toilet paper holders b- waste receptacles (covered in women's area) _ NA d- soap dispensers (no glass) NA e- mirrors unbreakable/safety glass NA 435.04 Sewage disposal acceptable Y/N By whom? NA 435.05 1). Location acceptable 2). Conform to national, state and local building codes OK 3). No projections on wall of pool 4). Walls acceptable _ Oi 435.06 1). Turnover rates: a- pool (eight hours) OK- 4.04 hrs. b- Wading pool (four hours) _ NA c- Special purpose pools (1/2 hr) _ NA d- Slide flumes (1 hr) NA 2). Equipment: a- filtration system _OK- Pentair CCP320 b- pump(s) OK- Pentair IntelliFlo VS 3.95 THP c- hair & lint strainer_ OK- with pump/motor d- feeder for sanitizer_ OK Pentair 300-29X (see calc notes) f- flowmeter (effluent) _ OK Rola-Chem 570361 g- balance tank/float tank/ above rim fill spout_ NA h- test kit - Not Shown/See Notes i- complete system _ OK (see notes) 3) Filtration rates: Rapid rates ( 3 gpm/sgft) 4 High rates ( 15 gpm/sqft- unless otherwise approved by NSF)_ NA DE (1.5 gpm/sqft or 2 gpm/sqft with continuous body feed)_ NA Nationwide Aquatic Consulting, Inc. IVAC, Inc• 3 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594/ 518-494-4045 Facility Checklist- MA Health Code Compliance© Cartridge (0.375 gpm/sgft) _OK— 0.175 gpm/sgft (see calc notes)_ Extra set of cartridges _ Not Shown/See Notes Variance necessary? NO 4). Chlorinators finely adjustable? _OK Delivery rate 3 lb chlorine/10,000 gals/24 hrs for outdoor pools _OK- (see calc notes) Delivery rate 1 lb chlorie/15,000 gals/24 hrs for indoor pools_ 5).Brominator? 6). Equipment labeled? accessible? _ 7). CO2: Section NA a- injection point in recerc pipe with 5 second contact time? b- cylinders secured/protected? c- 60 sqft floor space mechanical ventilation 3 minute air change? vent suction from floor opposite air intake? discharge 1 '/2" pipe minimum, does not contaminate outdoor area? 435.07 1). All materials non-toxic? _OK resistant to corrosion and stress? OK 2). Drainage of all piping and equipment? OK 435.08 1). Inlets placed for uniform recirculation? submerged/adjustable? _ 2). Fill spout: Section NA under board/next to ladder? no sharp edges? not greater than 2" out? at least 6" above water level? Nationwide Aquatic Consulting, Inc. IVAC, Inc. 4 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594/ 518-494-4045 Facility Checklist- MA Health Code Compliance© 3). Inlets: not a hazard? _ push surface debris toward skimmers? OK (c) not greater than 20' apart? OK not less than two (600 sift or less)? OK one per 600 sift or fraction thereof? OK velocity through inlets (15 feet/sec max.) _OK (see calc notes)_ main drains: lowest point of pool? OK pools over 30'- at least two? OK spacing not greater than 20' apart?_ OK spacing not more than 15' from walls? _ OK_ grating secured? — OK grating approved by OK- NSF water velocity through grating?—NA- VGB compliant open area non-entrapment? _ NA- VGB compliant grates anti-vortex? _ NA- VGB compliant grates non-tripping hazard? OIL two suction openings for each pump separated by 3' or two planes? _ OK 5). Special purpose/wading pools cut-off switch? 435.09 1). Cross connection(s)? NO- see notes 435.10 1). Water drawn 50% 50 % split from surface and bottom of pool?_ _ 2). Gutter capable of 50% of flow rate from pool? Section NP _ provide effective skimming? prevent flooding of deck? provide inspection and cleaning? not hazardous (sharp edges/openings)? opening for grating at least 2x area of piping? provides handhold for bathers? 3). Skimmers: Nationwide Aquatic Consulting, Inc. NAC, Inc 5 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-35941518-494-4045 Facility Checklist- MA Health Code Compliance© a- one per 500 sgft. (or major fraction thereof) of surface area? OK special purpose pools- one per 100 sgft. Of surface areas?_ NA b- weirs at least 3"? c-20 gallons/min/foot each weir? d- cleanable basket or screen? e- slide plate for balancing? OK f- skimmers 30 gpm, min.-total 50% of flow rate? _OK g- material acceptable? OK freeboard not greater than 6" (unless handhold provided)? _ OK 435.11 1). Swimming pool depth min. 3' slope 1' to 12' max. (depth 5' or less) exception needed from Board of Health? 2). Special purpose pools depth 5' max. depth of bench 2' max. NA 3). Walls: slope 1' to 5' max. OK competitive pools- walls vertical to 3.5' NA a- coves- depth 34' 12" radius max. OK b- coves- depth 4' & up radius=depth of pool minus 2.5_ OK ledges acceptable? _ NA 4). Ledge not more than 4" and about 4.5'? _ NA ledges sloped slightly toward main drain? NA 435.12 1). Depth markings on deck? OK- as per plan vertical wall visible from inside pool? OK markings 4" high minimum/dark colors? OK one foot depth intervals to a depth of 5'? OK appropriate places not greater than 25' around deep area _ OK polyethylene-line/floats at break? 2). 4" stripe at break? NA steps and ledges? NO- see notes 435.13 1). 4' walkways around pool? OK- see notes Nationwide Aquatic Consulting, Inc. NAC, Inc• 6 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594/ 518-494-4045 Facility Checklist- MA Health Code Compliance© 3" around diving board? %" per foot slope to deck drain? 435.14 1). One ladder per 75' of perimeter (min. 2) OK handrails? 2). Spa handrails? (min. 1) _ r� 435.15 Section NA 3). Diving board height 1 m max.? 13' overhead room (8' behind, left & right and 16' ahead)? 4). Competitive board(s)- FINA or NCAA standards? 5). Handrails 1 m- 30" over board and to edge of pool? Over 1 m- 36" over board and to edge of pool? 435.16 1). Water source approved by BOH? Y/N _OK- Domestic water_ Date? 435.17 2). Operator certified? Not Yet 435.18 1). Permit? Y/ ? Posted? 435.22 3). Signage? Not Shown/See Notes 4). Spa signage? NA 5). Spa clock? NF 435.24 Safety equipment? (one unit for 2000 sqft of surface area) ring buoys & rope? rescue tubes with lifeguard ( one per station)? backboard with lifeguards? rescue pole (outdoor pools only)? Nationwide Aquatic Consulting, Inc. NAC, Inc• 7 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594/ 518-494-4045 Facility Checklist- MA Health Code Compliance© 435.25 1). First aid kit compliant? Y/N Not Shown/See Notes 2). Emergency communication system? _OK 435.26 2 & 3). Disposal approved by BOW NA (cartridge filters) 4). Separation system for DE? Y/N NA 435.27 2). Bather load? _. 4). Special purpose bather load? NA 435.30 1). Test Kit DPD? Y/N _ Not Shown/See Notes Model 435.33 2). Special purpose pool(s) thermostat for high limit? Y/N Nationwide Aquatic Consulting, Inc. N C, Inc. 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594 / 518-494-4045 5/27/2025 David Greenbaum, RS, CHO Health Agent- Salem Board of Health 98 Washington St. Salem, MA 01970 David, Please find below the calculations for the pool to be built at the Residence at Canal St. Volume- To steps- L X W X D X 7.5= 39.5 X 11 X 4 X 7.5= 13035 Step area 3 X 11 X 3 X 7.5= + 371 2 13406 Piping, filter, heater, etc. +150 13556 gallons (design 13580 gallons) Volume was found to be well within the margin for error in pool volume `rounding' up/down. Surface Area- L X W = sqft. 44 X 11 = 484sgft. Turnover Rate- Vol - Flow Rate - 60 = hrs. 13580 = 56 gpm _ 60 = 4.04 hrs. (6 hr. minimum- OK) Filter Media Rate- Flow Rate Filter Surface area = gpm/sqft. 56gpm 320 sgft. = 0.175 gpm/sqft. (0.375 maximum- OK) Bather Load- Surface area _ 15 sqft/bather (depth under 5' = bathers 484 sgft - 15 sqft/bather = 32 (listed on print- OK) 1 Nationwide Aquatic Consulting, Inc. !V AC, Inc. 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594/ 518-494-4045 Chlorinator- (3lbs/10,000 gallons/ 24 hrs. required) Cut sheet states 8.05 Ibs per 24 hrs. maximum 13,550 gallons = 10,000= 1.355 X 3 lbs. =4.07 Ibs required- OK Return Velicity- Gpm Area X 3.12 = velocity feet per second 56 gpm/7 returns= 8 gpm per return Area of a 3/ orifice = .44179 8 (.44179 X 3.12)= 1.378 = 5.80 feet per second (15 fps maximum- OK) Thank you for the opportunity to assist in this project and if there are any questions or comments please don't hesitate to call or email. Regards: Robert R. Freligh, Pres. NAC, Inc. PO Box 695 Chestertown, NY 12817 2 Nationwide Aquatic Consulting, Inc. NAC, Inc. 304 Nahant Rd. Box 695 Nahant, MA 01908 Chestertown, NY 12817 1-888-833-5770 Fax 781-581-3594 / 518-494-4045 888-833-5770 nac4h2o@aol.com 3