Full Set (1)INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
60 DERBY ST
SALEM, MA 01970
42.5241, -70.8821
DERBY ST
P1 ISSUED TO TOWNSHIP FOR PERMIT 7/28/2025
NO.DESCRIPTION DATE
BROWN, LOUISE
TRINITY ACCT #: 2025-07-1365014
60 DERBY ST
SALEM, MA 01970
42.5241, -70.8821
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:7/28/2025
DRAWN BY:WK
REVISED BY:
DC SYSTEM SIZE:5.33kW
AC SYSTEM SIZE:5.76kW
MODULE COUNT:13
MODULES USED:HANWHA 410
MODULE SPEC #:Q.PEAK DUO BLK ML-G10.C+ 410
UTILITY COMPANY:NAT'L GRID
UTILITY ACCT #:62974-77015
UTILITY METER #:12289258
DEAL TYPE:GOODLEAP
P1
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
ROOF 1
MODULES: 4 PITCH: 30 ORIENTATION: 299
ROOF 2 MODULES: 9
PITCH: 30
ORIENTATION: 119
ROOF 3 MODULES: 0 PITCH: 0°
ORIENTATION: 209°
ROOF 4
MODULES: 0 PITCH: 10° ORIENTATION: 209°
ROOF 5 MODULES: 0
PITCH: 10° ORIENTATION: 29°
DC
AC D
ep
M
***NOTE: 2021 IRC R324.6.2
PLAN VIEW TOTAL ROOF AREA: 1499 FT²
PHOTOVOLTAIC ARRAY TOTAL AREA: 285 FT²
ARRAY PERCENTAGE OF PLAN VIEW TOTAL ROOF AREA: 19%
***NOTE: PV DISCONNECT 24/7 ACCESSIBLE AND LOCKABLE
N
S
27
0
90
135
225
4
5
315
13 HANWHA 410 (Q.PEAK DUO BLK ML-G10.C+ 410)
1 USE5700H-USMNBE78
13 U650 SE OPTIMIZERS
7 UNIRAC 171RLM1-US NXT UMOUNT RAIL - 171” MILL (US)
5 UNIRAC RLSPLCM2-US NXT UMOUNT RAIL SPLICE (US)
INSIDE OUTSIDE.
OUTSIDE (UTILITY ACCESSIBLE)OUTSIDE.
P1 ISSUED TO TOWNSHIP FOR PERMIT 7/28/2025
NO.DESCRIPTION DATE
BROWN, LOUISE
TRINITY ACCT #: 2025-07-1365014
60 DERBY ST
SALEM, MA 01970
42.5241, -70.8821
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:7/28/2025
DRAWN BY:WK
REVISED BY:
DC SYSTEM SIZE:5.33kW
AC SYSTEM SIZE:5.76kW
MODULE COUNT:13
MODULES USED:HANWHA 410
MODULE SPEC #:Q.PEAK DUO BLK ML-G10.C+ 410
UTILITY COMPANY:NAT'L GRID
UTILITY ACCT #:62974-77015
UTILITY METER #:12289258
DEAL TYPE:GOODLEAP
P1
NOTES:
1.) ALL EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS.
2.)
3.) ALL LOCATIONS ARE APPROXIMATE AND REQUIRE FIELD VERIFICATION.
ALL OUTDOOR EQUIPMENT SHALL BE RAIN TIGHT WITH MINIMUM NEMA 3R RATING.
M
UD SP
P
DC
AC
ep
D
DC
SD
TS 2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
CALCULATIONS FOR CURRENT CARRYING CONDUCTORS
REQUIRED CONDUCTOR AMPACITY PER STRING
[NEC 690.8(B)(1)]: (15.00*1.25)1 = 18.75A
AWG #10, DERATED AMPACITY
AMBIENT TEMP: 33°C, TEMP DERATING FACTOR: .96
RACEWAY DERATING = 2 CCC: 1.00
(40*.96)1.00 = 38.40A
38.40A >_ 18.75A, THEREFORE WIRE SIZE IS VALID
TOTAL AC REQUIRED CONDUCTOR AMPACITY
24.00A*1.25 = 30.00A
AWG #10, DERATED AMPACITY
AMBIENT TEMP: 30°C, TEMP DERATING: 1.0
RACEWAY DERATING <_ 3 CCC: N/A
40A*1.0 = 40A
40A >_ 30.00A, THEREFORE AC WIRE SIZE IS VALID
CALCULATION FOR PV OVERCURRENT PROTECTION
TOTAL INVERTER CURRENT: 24.00A
24.00A*1.25 = 30.00A
--> 30A OVERCURRENT PROTECTION IS VALID
ARRAY CIRCUIT WIRING NOTES
1.) LICENSED ELECTRICIAN ASSUMES ALL RESPONSIBILITY
FOR DETERMINING ONSITE CONDITIONS AND
EXECUTING INSTALLATION IN ACCORDANCE WITH
NEC 2023
2.) LOWEST EXPECTED AMBIENT TEMPERATURE BASED ON
ASHRAE MINIMUM MEAN EXTREME DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. LOWEST EXPECTED AMBIENT
TEMP = -16°C
3.) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED
ON ASHRAE HIGHEST MONTH 2% DRY BULB
TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO
INSTALLATION LOCATION. HIGHEST CONTINUOUS TEMP =
33°C
4.) 2005 ASHRAE FUNDAMENTALS 2% DESIGN
TEMPERATURES DO NOT EXCEED 47°C IN THE UNITED
STATES (PALM SPRINGS, CA IS 44.1°C). FOR LESS THAN 9
CURRENT-CARRYING CONDUCTORS IN A ROOF-MOUNTED
SUNLIT CONDUIT AT LEAST 0.5" ABOVE ROOF AND USING
THE OUTDOOR DESIGN TEMPERATURE OF 47°C OR LESS
(ALL OF UNITED STATES)
5.) PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS
SHALL INCLUDE A RAPID SHUTDOWN FUNCTION THAT
CONTROLS SPECIFIC CONDUCTORS IN ACCORDANCE WITH
NEC 690.12(A) THROUGH (D)
6.) PHOTOVOLTAIC POWER SYSTEMS SHALL BE PERMITTED
TO OPERATE WITH UNGROUNDED PHOTOVOLTAIC
SOURCE AND OUTPUT CIRCUIT PER NEC 690.41 (A)(4)
7.) UNGROUNDED DC CIRCUIT CONDUCTORS SHALL BE
IDENTIFIED WITH THE FOLLOWING OUTER FINISH:
POSITIVE CONDUCTORS = RED
NEGATIVE CONDUCTORS = BLACK
NEC 210.5(C)(2)
8.) ARRAY AND SUB ARRAY CONDUCTORS SHALL BE #10 PV
WIRE TYPE RHW-2 OR EQUIVELANT AND SHALL BE
PROTECTED BY CONDUIT WHERE EXPOSED TO DIRECT
SUNLIGHT. SUB ARRAY CONDUIT LONGER THAN 24” SHALL
CONTAIN ≤ 20 CURRENT CARYING CONDUCTORS AND
WHERE EXPOSED TO DIRECT SUNLIGHT SHALL CONTAIN ≤
9 CURRENT CARRYING CONDUCTORS.
9.) ALL WIRE LENGTHS SHALL BE LESS THAN 100' UNLESS
OTHERWISE NOTED
10.) FLEXIBLE CONDUIT SHALL NOT BE INSTALLED ON
ROOFTOP AND SHALL BE LIMITED TO 12” IF USED
OUTDOORS
11.) DISCONNECTS FED BY SUPPLY-SIDE SOURCE
CONDUCTORS SHALL BE BONDED AND CONNECTED TO
GROUNDING SYSTEM IN ACCORDANCE WITH
NEC 250.24
12.)OVERCURRENT PROTECTION FOR CONDUCTORS
CONNECTED TO THE SUPPLY SIDE OF A SERVICE SHALL BE
LOCATED WITHIN 10' OF THE POINT OF CONNECTION
NEC 690.9(A)(3)(2)
13.) WHERE TWO SOURCES FEED A BUSSBAR, ONE A
UTILITY AND THE OTHER AN INVERTER, PV BACKFEED
BREAKER(S) SHALL BE LOCATED OPPOSITE FROM UTILITY
NEC 705.12(B)(2)
14.) ALL SOLAR SYSTEM LOAD CENTERS TO CONTAIN ONLY
GENERATION CIRCUITS AND NO UNUSED POSITIONS OR
LOADS
15.) ALL EQUIPMENT INSTALLED OUTDOORS SHALL HAVE
A NEMA 3R RATING
BONDED NEUTRAL
240V 1Ø
SQUARE D
PN: D222NRB
LOCKABLE 60A DISCONNECT
FUSED W/ 30A FUSES
NOTE:
INTERNAL REVENUE GRADE MONITORING
CONTAINED WITHIN SOLAR EDGE INVERTER
SOLAR EDGE PN. RWND-3D-240-MB
NE
U
T
R
A
L
EXISTING
MAIN BREAKER LOAD CENTER
INSULATED LINE TAPS
INSTALLED ON MAIN FEEDERS
NEC 705.11
M
2p
20
0
A
MA
I
N
240V 1Ø
200A MAIN BREAKER
200A BUSBAR
a
EXISTING
120/240V
UTILITY METER
EG
INVERTER #1 - USE5700H-USMNBE78
DC AC
Imp 14.03 Pout 5760
Vmp 380 Imax 24
Voc 480 OCPDmin 30
Isc 15 Vnom 240
PV MODULE SPECIFICATIONS
HANWHA 410 (Q.PEAK DUO BLK ML-G10.C+ 410)
Imp 10.89
Vmp 37.64
Voc 45.37
Isc 11.2
A #6 THWN-2 TO GEC
B 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND
C 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2 GROUND
D 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2 GROUND
E 3/4'' CONDUIT W/ 2-#10 THWN-2, 1-#10 THWN-2, 1-#10 THWN-2 GROUND
F #10 PV WIRE (FREE AIR) W/ #6 BARE COPPER BOND TO ARRAY
G 3/4'' CONDUIT W/ 2-#6 THWN-2, 1-#6 THWN-2
NOTE: CONDUIT TYPE SHALL BE CHOSEN BY THE INSTALLATION CONTRACTOR
TO MEET OR EXCEED NEC AND LOCAL AHJD REQUIREMENTS
INVERTER #1
PV +
L1 L2 N
PV -
D
SOLAR MODULES MOUNTED TO ROOF ON 2 ARRAYS
13 - 410W MODULES W/ 1 SOLAR EDGE U650 PER MODULE
15 ADC MAX PER STRING
1 STRING OF 13 MODULES IN SERIES - 380 Vmax
*TERMINATED INSIDE INVERTER 1
f 8"x8"
JUNCTION
BOX
C
T
M
E
T
E
R
S
***NATIONAL GRID NOTES:
ANY NEW METERING AND DISCONNECT EQUIPMENT SHALL BE GROUPED,
LOCATED OUTSIDE, AND 24/7 LOCKABLE AND ACCESSIBLE, IN ACCORDANCE WITH
ESB 7.1.1. ALL EQUIPMENT LOCATIONS SHALL BE APPROVED BY NATIONAL GRID
METERING DEPARTMENT PRIOR TO INSTALLATION.
ALL CONSTRUCTION SHALL COMPLY WITH ESB 750 & ESB 756. INSTALLATIONS
CANNOT INCLUDE ANY KIND OF TAPS, METER COLLARS OR ADAPTERS INSIDE
NATIONAL GRID OWNED AND MAINTAINED EQUIPMENT, METER SOCKETS, METER
CABINETS OR ANYWHERE THERE ARE UN-METERED CONDUCTORS.
P1 ISSUED TO TOWNSHIP FOR PERMIT 7/28/2025
NO.DESCRIPTION DATE
BROWN, LOUISE
TRINITY ACCT #: 2025-07-1365014
60 DERBY ST
SALEM, MA 01970
42.5241, -70.8821
PROPOSED PV SOLAR SYSTEM
DRAWING DATE:7/28/2025
DRAWN BY:WK
REVISED BY:
DC SYSTEM SIZE:5.33kW
AC SYSTEM SIZE:5.76kW
MODULE COUNT:13
MODULES USED:HANWHA 410
MODULE SPEC #:Q.PEAK DUO BLK ML-G10.C+ 410
UTILITY COMPANY:NAT'L GRID
UTILITY ACCT #:62974-77015
UTILITY METER #:12289258
DEAL TYPE:GOODLEAP
P1
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
JOB NAME:BROWN, LOUISE
ADDRESS:60 Derby St
Salem, MA 01970
42.5241, -70.8821
30.782 ESTIMATED PERSONNEL HOURS 1.28 DAYS 0.96 DAYS 0.64 DAYS
•13 HANWHA 410's (5.33KW)(CREW OF 3)(CREW OF 4)(CREW OF 6)
•2 SEPARATE ARRAYS
•26' PEAK TO GROUND
•13 PORTRAIT & 0 LANDSCAPED
•1 INVERTER(S) INSTALLED OUTSIDE
•NO TRENCH
ESTIMATED SENT TO JOB USED
□HANWHA 410 (Q.PEAK DUO BLK ML-G10.C+ 410)13 ______
□U650 SE OPTIMIZERS 13 ______
□USE5700H-USMNBE78 1 ______
□60A OUTDOOR FUSED DISCONNECT W/ (2) 30A FUSES 1 ______
□60A OUTDOOR NON-FUSED DISCONNECT 1 ______
□SOLADECK BOX(ES) & HAYCO CONNECTOR(S)2 ______
□PV LEAD WIRE 50'______
□INSULATED BUG BITES (TAPS)2 ______
□SOLAREDGE CONSUMPTION CTs (SECT-SPL-225-T-20)2 ______
□UNIRAC 171RLM1-US NXT UMOUNT RAIL - 171” MILL (US)7 ______
□UNIRAC RLSPLCM2-US NXT UMOUNT RAIL SPLICE (US)5 ______
□UNIRAC CCLAMPD1 NXT UMOUNT COMBO CLAMP - DARK 30 ______
□GROUNDING LUG(S)2 ______
□UNIRAC SHCLMPD2 STRONGHOLD RAIL CLAMP DARK 28 ______
□UNIRAC 004055D FLASHKIT PRO 28 ______
□UNIRAC MLPEMNT MLPE MOUNT 13 ______
□UNIRAC ENDCAPD1 NXT UMOUNT RL & CLMP CAP KIT 8 ______
MATERIAL LIST
(FOR INTERNAL USE ONLY)
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
INSTALLATION OF NEW
ROOF MOUNTED PV SOLAR SYSTEM
60 DERBY ST
BROWN, LOUISE
60 DERBY ST
SALEM, MA 01970
42.5241, -70.8821
APPENDIX
CONTENTS
LABELS, STICKERS, AND PLACARDS
EQUIPMENT DATA SHEETS
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com
2211 Allenwood Road
Wall, New Jersey 07719
877-786-7283
www.Trinity-Solar.com