7.5 Lyme Street Elevation and Floor PlansSheet No.
Drawing Name
Scale:
Date:
Drawn By:
A0.0
COVER SHEET
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
No. Description Date
7-1/2 LYME STREET
SALEM, MA 01970
GOOGLE MAPS
A0.0 COVER SHEET
Architectural
A0.1 GENERAL NOTES
A1.0 PROPOSED FLOOR PLANS
A2.0 PROPOSED EXTERIOR
ELEVATIONS
D1.0 EXISTING DEMOLITION PLANS
D1.1 EX. EXTERIOR DEMOLITION
ELEVATIONS
S1.0 STRUCTURAL PLANS
S1.1 STRUCTURAL PLANS
Grand total: 8
DRAWING LIST
RENOVATION OF EXISTING SINGLE-FAMILY
RESIDENCE; DEMOLITION OF EXISTING ROOF TO
FACILITATE PROPOSED DORMER INSTALLATION;
ADDITION TO REAR OF SECOND FLOOR.
SCOPE OF WORK
SINGLE-FAMILY RENOVATION / ADDITION
PHASE: SCHEMATIC DESIGN
NOTE: 3D VIEWS SHOWN FOR VISUAL REPRESENTATION PURPOSES ONLY PER
SCOPE OF WORK; PARTS OF BUILDING / ENVELOPE MAY BE HIDDEN FOR CLARITY.
A0.0
1 PROPOSED 3D VIEW
A0.0
2 EXISTING 3D VIEW
ARCHITECTURAL
1. ALL HABITABLE ROOMS, EXCEPT KITCHENS, ARE TO HAVE AN AREA OF NOT LESS THEN 70 SQ FT WITH A MINIMUM OF 7
FT IN ANY DIMENSION. - IRC R304
2. MINIMUM WINDOW AREA SHALL EQUAL NOT LESS THAN 8% OF THE FLOOR AREA OF THE ROOM UNLESS ARTIFICIAL
LIGHT IS PROVIDED CAPABLE OF PRODUCING AN AVERAGE ILLUMINATION OF 6 FOOT CANDLES OVER THE AREA OF THE
ROOM AT A HEIGHT OF 30 INCHES. - IRC R303
3. WHERE THE AIR INFILTRATION RATE OF A DWELLING UNIT IS 5 AIR CHANGES PER HOUR OR LESS WHERE TESTED W ITH
A BLOWER DOOR AT A PRESSURE OF 0.2 INCH W.C. (50 PA) IN ACCORDANCE WITH SECTION N1102.4.1.2, THE DWELLING
UNIT SHALL BE PROVIDED WITH WHOLE-HOUSE MECHANICAL VENTILATION IN ACCORDANCE WITH SECTION M1507.3 - IRC
R303.4
4. BATHROOMS, WATER CLOSET COMPARTMENTS AND OTHER SIMILAR ROOMS SHALL BE PROVIDED WITH AGGREGATE
GLAZING AREA IN WINDOWS OF NOT LESS THAN 3 SQ FT, ONE-HALF OF WHICH MUST BE OPERABLE. EXCEPTION: THE
GLAZED AREAS SHALL NOT BE REQUIRED WHERE ARTIFICIAL LIGHT AND A LOCAL EXHAUST SYSTEM ARE PROVIDED. THE
MINIMUM LOCAL EXHAUST RATES SHALL BE DETERMINED IN ACCORDANCE WITH SECTION M1507. EXHAUST AIR FROM
THE SPACE SHALL BE EXHAUSTED DIRECTLY TO THE OUTDOORS. - IRC R303.3
5. MECHANICAL AND GRAVITY OUTDOOR AIR INTAKE OPENINGS SHALL BE LOCATED NOT LESS THAN 10 FEET FROM ANY
HAZARDOUS OR NOXIOUS CONTAMINANT, SUCH AS VENTS, CHIMNEYS, PLUMBING VENTS, STREETS, ALLEYS, PARKING
LOTS AND LOADING DOCKS. EXHAUST AIR SHALL NOT BE DIRECTED ONTO WALKWAYS. - IRC R303.5
6. HABITABLE SPACE AND HALLWAYS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 7 FEET. BATHROOMS, TOILET
ROOMS, LAUNDRY ROOMS, AND HABITABLE SPACE IN BASEMENTS SHALL HAVE A CEILING HEIGHT OF NOT LESS THAN 6
FEET, 8 INCHES. - R305.1
7. EMERGENCY EGRESS FOR BASEMENTS WITH HABITABLE SPACE AND EACH SLEEPING ROOM: AN EXTERIOR DOOR OR
WINDOW WITH A FINISHED SILL HEIGHT WITHIN 44" OF THE FLOOR, MINIMUM NET CLEAR OPERABLE AREA OF 5.7 SQ FT,
MINIMUM NET CLEAR OPERABLE WIDTH OF 20" AND MINIMUM NET CLEAR OPERABLE HEIGHT OF 24". GRADE FLOOR
OPENINGS MAY HAVE A MINIMUM NET CLEAR OPENING OF 5 SQ FT. - IRC R310
8. GLAZING USED IN DOORS AND PANELS OF SHOWERS AND BATHTUB ENCLOSURES AND WALLS ENCLOSING THESE
COMPARTMENTS SHALL BE TEMPERED. - IRC TABLE R308.3
9. TEMPERED GLASS SHALL BE PROVIDED IN: FRAMELESS GLASS DOORS, GLASS IN DOORS, GLASS WITHIN A 24" ARCH OF
DOORS, GLAZING LESS THAN 60" ABOVE A WALKING SURFACE THAT IS WITHIN 5 FT OF STAIRS, OR GLAZING WITHIN 5 FT
OF SPAS OR POOLS, CERTAIN FIXED GLASS PANELS, AND SIMILAR GLAZED OPENINGS SUBJECT TO HUMAN IMPACT. - IRC
R308
10. NOT LESS THAN 1/2 INCH GYPSUM BOARD ON THE GARAGE SIDE OF THE WALL AND CEILING SEPARATING A GARAGE
AND A DWELLING. WHERE THE SEPARATION IS A FLOOR-CEILING ASSEMBLY, THE ASSEMBLY AND THE STRUCTURE
SUPPORTING THE SEPARATION SHALL BE PROTECTED WITH NOT LESS THAN 5/8 INCH TYPE X GYPSUM BOARD ON THE
CEILING. - IRC R309.2 AND R302.6
11. DOORS LEADING FROM DWELLINGS TO THE GARAGE SHALL BE 1-3/8" THICK SOLID CORE OR 20 MINUTE RATED.
DOORS SHALL NOT OPEN INTO A SLEEPING ROOM. ELECTRICAL PANELS PENETRATING THE GARAGE SIDE GYPSUM
BOARD MEMBRANE SHALL BE WRAPPED WITH 5/8" TYPE X GYPSUM BOARD ON THE TOP, BOTTOM, SIDES, AND BACK. - IRC
R302.5.1
12. STAIRWAYS SHALL NOT BE LESS THAN 36 INCHES IN CLEAR WIDTH AT ALL POINTS ABOVE THE PERMITTED HANDRAIL
HEIGHT. HANDRAILS SHALL NOT PROJECT MORE THAN 4.5 INCHES ON EITHER SIDE. - IRC 311.7.1
13. THE TOPS OF HANDRAILS SHALL BE PLACED BETWEEN 34 INCHES AND 38 INCHES ABOVE THE NOSING OF THE TREADS.
THEY SHALL BE CONTINUOUS THE FULL LENGTH OF THE STAIRS. ENDS SHALL BE RETURNED OR SHALL TERMINATE IN
NEWEL POSTS OR SAFETY TERMINALS. THE HANDGRIP PORTION OF HANDRAILS SHALL BE NOT LESS THAN 1-1/4 INCHES
NOR MORE THAN 2-5/8 INCHES IN CROSS-SECTIONAL DIMENSION OR THE SHAPE SHALL PROVIDE AN EQUIVALENT
GRIPPING SURFACE. HANDRAILS PROJECTING FROM A WALL SHALL HAVE A SPACE OF NOT LESS THAN 1.5 INCHES
BETWEEN THE WALL AND THE HANDRAIL. - IRC R311.7
14. ALL UNENCLOSED FLOOR AND ROOF OPENINGS, OPEN AND GLAZED SIDES OF LANDINGS AND STAIRS, BALCONIES,
AND PORCHES MORE THAN 30 INCHES ABOVE GRADE, AND ROOFS USED FOR OTHER THAN SERVICE OF THE BUILDING
SHALL BE PROTECTED BY A GUARD (AKA "GUARDRAIL"). GUARDS SHALL NOT BE LESS THAN 36 INCHES IN HEIGHT. OPEN
GUARDS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN SUCH THAT NO SPHERE 4 INCHES IN DIAMETER
CAN PASS THROUGH. - IRC R312
15. THE MINIMUM HEADROOM IN ALL PARTS OF A STAIRWAY SHALL NOT BE LESS THAN 6'-8" MEASURED VERTICALLY FROM
THE SLOPED PLANE ADJOINING THE TREAD NOSING OR FROM THE FLOOR SURFACE OF THE LANDING OR PLATFORM. - IRC
R311.7.2
16. LANDINGS SHALL HAVE A MINIMUM DIMENSION MEASURED IN THE DIRECTION OF TRAVEL OF 36 INCHES. - IRC R311
17. ALL LUMBER IN CONTACT WITH CONCRETE OR MASONRY INCLUDING LEDGERS AND FURRING WALLS MUST BE
PRESERVATIVELY TREATED. - IRC R317
18. PROVIDE 1/2" AIRSPACE AT TOPS, SIDES, AND ENDS OF GIRDERS ENTERING EXTERIOR CONCRETE OR MASONRY
WALLS UNLESS WOODS RESISTANT TO DECAY ARE USED. - IRC R317
19. NO WOOD SHALL BE NEARER THAN 8 INCHES TO EARTH UNLESS SEPARATED BY CONCRETE AT LEAST 3 INCHES IN
THICKNESS WITH AN IMPERVIOUS MEMBRANE INSTALLED BETWEEN THE EARTH AND CONCRETE. THIS INCLUDES DECKS
AND SIDINGS. - IRC R317
20. COMPOSITION SHINGLES SHALL NOT BE INSTALLED ON ROOFS HAVING A SLOPE LESS THAN 4 TO 12 UNLESS DOUBLE
UNDERLAYMENT IS INSTALLED IN ACCORDANCE WITH IRC SECTION R905.2.2
21. ASPHALT SHINGLE, CLAY AND CONCRETE TILE, METAL SHINGLE, MINERAL-SURFACED WOOL ROOFING, SLATE AND
SLATE-TYPE SHINGLE, WOOD SHINGLE, AND WOOD SHAKE ROOF MATERIALS REQUIRE AN ICE BARRIER THAT EXTENDS
FROM THE EDGE OF THE EAVES TO A POINT NOT LESS THAN 24 INCHES INSIDE THE EXTERIOR WALL LINE OF THE
BUILDING. - IRC R905
22. ACCESSIBLE BELOW-FLOOR AREAS SHALL BE PROVIDED WITH A MINIMUM 18" X 24" ACCESS OPENING. IRC R408.4.
FOR ACCESS TO MECHANICAL EQUIPMENT IN THESE AREAS SEE IRC M1305.1.4
23. CROSS VENTILATION FOR ENCLOSED ATTICS AND SPACES BETWEEN RAFTERS FOR EACH SEPARATE SPACE.
VENTILATING OPENINGS SHALL BE PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW. THE TOTAL NET FREE
VENTILATING AREA SHALL NOT BE LESS THAN 1 TO 150 OF THE AREA OF THE SPACE VENTILATED. THIS MAY BE REDUCED
TO NOT LESS THAN 1 TO 300 IF: (1) OPENINGS ARE PROVIDED IN THE UPPER AND LOWER PORTIONS OF THE VENTILATED
SPACE, OR (2) A 1 PERM VAPOR BARRIER IS INSTALLED ON THE WARM SIDE OF THE CEILING. - IRC R806
24. UNVENTED CONDITIONED ATTIC ASSEMBLIES SHALL COMPLY WITH R806.5
25. MINIMUM 22" X 30" ATTIC ACCESS IN A HALLWAY OR OTHER READILY ACCESSIBLE LOCATION. - IRC R807. SEE M1305.1.3
FOR ACCESS TO FURNACES AND OTHER MECH. EQUIPMENT IN ATTICS.
26. EXTERIOR SIDING SHALL COMPLY WITH R703.11 AND TABLE R703.3(1)
27. MINIMUM 4-MIL POLYETHYLENE VAPOR RETARDER OVER THE INSULATION ON THE INSIDE (WARM SIDE) OF ALL
EXTERIOR WALLS AND ROOF CEILINGS. - IRC R702.7
28. EXTERIOR WALLS SHALL PROVIDE THE BUILDING WITH A WEATHER-RESISTIVE EXTERIOR WALL ENVELOPE. PROVIDE
WEATHER-RESISTIVE BARRIER FLASHING DETAILS FOR WINDOWS, DOOR, AND OTHER OPENINGS IN THE BUILDING
ENVELOPE, INCLUDE MANUFACTURER'S INSTALLATION INSTRUCTIONS. ALSO PROVIDE FLASHING DETAILS OVER DOORS,
WINDOWS, SILLS, AT FOUNDATION, COLUMNS, AND OTHER LOCATIONS REQUIRING FLASHINGS. R703.1 AND R703.4
29. TUBS AND SHOWERS WITH TILED WALLS REQUIRE A PORTLAND CEMENT APPLICATION, FIBERED-CEMENT OR GLASS
MAT GYPSUM BACKER
30. THE DRAWINGS THAT INSPECTIONS ARE REQUIRED FOR ALL STUCCO AND EIFS SYSTEMS. PROVIDE PRODUCT
SPECIFICATIONS AND ICBO EVALUATION REPORT (OR EQUAL) FOR ANY STUCCO OR EIFS SYSTEM USED. - IRC R109.1.5
31. WINDOW WELLS WILL PROVIDE A MINIMUM NET CLEAR OPENING OF 9 SQ FT WITH A MINIMUM DIMENSION OF 36
INCHES. SHOW A PERMANENT LADDER IF WINDOW WELL IS MORE THAN 44 INCHES DEEP. - IRC R310.2
32. SILLS OF EXTERIOR WINDOWS WHICH ARE LOCATED MORE THAN 6 FEET ABOVE GRADE, AND LESS THAN 24 INCHES
ABOVE THE INTERIOR FLOOR SURFACE MUST MEET SOME NEW REQUIREMENTS. THE AREA OF THE WINDOW LESS THAN
24 INCHES ABOVE THE INTERIOR FLOOR SURFACE MUST NOW BE FIXED OR HAVE AN OPENING OR A GUARD WHICH DOES
NOT ALLOW THE PASSAGE OF A 4 INCH DIAMETER SPHERE. R312.2
33. A PERMANENT CERTIFICATE SHALL BE POSTED ON OR IN THE ELECTRICAL DISTRIBUTION PANEL LISTING THE
PREDOMINANT R-VALUES OF INSULATION INSTALLED IN OR ON CEILING / ROOF, WALLS, FOUNDATIONS (SLAB, BASEMENT
WALL, CRAWLSPACE WALL AND/OR FLOOR) AND DUCTS OUTSIDE THE CONDITIONED SPACES; U-FACTORS OF WINDOWS,
AND THE SOLAR HEAT GAIN COEFFICIENT OF WINDOWS. THE TYPE AND EFFICIENCY OF HEATING, COOLING AND SERVICE
WATER HEATING EQUIPMENT SHALL ALSO BE LISTED. NOTE: THE LISTING WILL NOT ALLOW YOU TO DRILL OR MODIFY THE
PANEL OR COVER IN ANY WAY ACCOMPLISH THIS. IRC N1101.10
34. SHOWERS SHALL HAVE DOORS SIZED TO PROVIDE A MINIMUM OF 22 INCHES NET CLEAR OPENING. P2708.1.1
35. THE RISER HEIGHT SHALL BE NOT MORE THAN 8 1/4 INCHES. THE RISER SHALL BE MEASURED VERTICALLY BETW EEN
LEADING EDGES OF THE ADJACENT TREADS. THE GREATEST RISER HEIGHT WITHIN ANY FLIGHT OF STAIRS SHALL NOT
EXCEED THE SMALLEST BY MORE THAN 3/8 INCH. RISERS SHALL BE VERTICAL OR SLOPED FROM THE UNDERSIDE OF THE
NOSING OF THE TREAD ABOVE AT AN ANGLE NOT MORE THAN 30 DEGREES FROM THE VERTICAL. OPEN RISERS ARE
PERMITTED PROVIDED THAT THE OPENINGS LOCATED MORE THAN 30 INCHES, AS MEASURED VERTICALLY, TO THE FLOOR
OR GRADE BELOW DO NOT PERMIT THE PASSAGE OF A FOUR-INCH-DIAMETER SPHERE. R311.7.5.1
36. THE TREAD DEPTH SHALL BE NO LESS THAN NINE INCHES. THE TREAD DEPTH SHALL BE MEASURED HORIZONTALLY
BETWEEN THE VERTICAL PLANES OF THE FOREMOST PROJECTION OF ADJACENT TREADS AND AT A RIGHT ANGLE TO THE
TREAD'S LEADING EDGE. THE GREATEST TREAD DEPTH WITHIN ANY FLIGHT OF STAIRS SHALL NOT EXCEED THE
SMALLEST BY MORE THAN 3/8 INCH. R311.7.5.2
37. NOSINGS. THE RADIUS OF CURVATURE AT THE NOSING SHALL BE NOT GREATER THAN 9/16 INCH. A NOSING
PROJECTION NOT LESS THAN 3/4 INCH AND NOT MORE THAN 1 1/4 INCHES SHALL BE PROVIDED ON STAIRWAYS WITH
SOLID RISERS. THE GREATEST NOSING PROJECTION SHALL NOT EXCEED THE SMALLEST NOSING PROJECTION BY MORE
THAN 3/8 INCH BETWEEN TWO STORIES, INCLUDING THE NOSING AT THE LEVEL OF FLOORS AND LANDINGS. BEVELING OF
NOSINGS SHALL NOT EXCEED 1/2 INCH. R11.7.5.3
CONSTRUCTION NOTES
GENERAL:
A)
1. REPAIR ANY DAMAGED STAIR TREADS AND RISERS.
2. REPLACE ALL OLD DAMAGED DOORS AND WINDOWS WITH ENERGY CODE REQUIRED REPLACEMENTS
3. G.C. IS RESPONSIBLE FOR MAINTAINING THE FIRE RATING INTEGRITY AT ALL DEMISING & FIRE RATED WALLS AS WELL AS
AT THE SLAB AND THE CEILING/ROOF
4. WHEREVER WALL OR ROOF CAVITIES ARE OPENED, INSULATE EXISTING CAVITIES AT R3.5/INCH TO THE THICKNESS OF
THE EXISTING CAVITIES.
5. PROVIDE R-49 CAVITY INSULATION AT ROOF IF AND WHEN ANY ROOF ELEMENT IS CHANGE IN ANY WAY.
6. SLEEVE, FIRESTOP, AND CAULK ALL PENETRATIONS OF FLOORS SO THAT ODORS AND/OR LIQUIDS WILL NOT PENETRATE
THE SLAB. DO THE SAME IN FLOORS BETWEEN UNITS.
7. G.C. IS TO PROVIDE LABELS AT COMMON WIRING THROUGHOUT TO IDENTIFY COMMON ELECTRICAL SERVICE.
8. PROVIDE A FULL CLEANING, BROOM-SWEPT, OF BUILDING PRIOR TO OCCUPANCY.
9. INCLUDE REPLACING ALL GWB/PLASTER. INCLUDE PAINTING ALL ROOMS AND CEILINGS.
10. INCLUDE REWIRING BUILDING. INCLUDE NEW PANELS.
11. REPLACE ANY DAMAGED PIPING, EQUIPMENT, OR MECHANICAL UNITS AS NEEDED.
12. FOLLOW ALL APPLICABLE CODES AND REGULATIONS.
13. WORK TO BE PERFORMED IN A PROFESSIONAL AND LAWFUL MANNER.
14. WORKMANSHIP STANDARD OF CARE TO MEET INDUSTRY STANDARD/EXPECTATIONS.
15. G.C. TO PROVIDE ALL NECESSARY PERMITS.
16. G.C. TO CARRY ALL INSURANCE REQUIRED BY LAW; G.C. TO CARRY INSURANCE AS WOULD BE TYPICAL FOR THIS SCOPE
OF WORK.
LAYOUT:
B)
1. LAYOUT PARTITIONS STARTING FROM CONDITIONS WHERE ALIGNMENT WITH EXISTING CONDITIONS IS SHOWN, U.N.O.
2. DRAWINGS ARE NOT BE SCALED, DIMENSIONS GOVERN, IF DIMENSIONS ARE MISSING OR UNCLEAR, G.C. SHALL NOTIFY
ARCHITECT FOR DIRECTION.
3. G.C. TO VERIFY EXTENT OF WALL DAMAGE.
4. G.C. TO VERIFY THAT ALL EXISTING DEMISING WALLS ARE PLUMB. IF NOT G.C. TO PROVIDE AND INSTALL FURRING AND
GWB TO MAKE PLUMB.
5. TYPICAL INTERIOR PARTITIONS ARE TYPE "A", UNLESS OTHERWISE NOTED TO MATCH EXISTING CONDITIONS
6. PROVIDE CONVENIENCE ELECTRICAL OUTLETS EVERY 12 LINEAR FEET OF ROOM PERIMETER. PROVIDE GFIC OUTLETS @
48" AFF IN BATHROOMS
7. MATCH NEW LIGHTING WITH EXISTING AS MUCH AS POSSIBLE. PROVIDE ASSOCIATED SWITCHES
COORDINATION:
B)
1. G.C. SHALL VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS, NOTIFY OWNER IMMEDIATELY OF ANY MAJOR
DISCREPANCIES
2. G.C. TO COORDINATE ALL TRADES PRIOR TO COMMENCING ANY WORK
3. G.C. TO NOTIFY OWNER AFTER LAYOUT AND PRIOR TO FRAMING IF: DIMENSION LABELED +/- VARIES MORE THAN 2" FROM
ACTUALLY FIELD MEASUREMENT; ANY DISCREPANCY, OMISSION OR UNANTICIPATED FILED CONDITION ALTERS THE INTENT
OF THESE DRAWINGS; ANY DIMENSIONS LABELED "MIN" CANNOT BE ACHIEVED
4. G.C. SHALL SUPPLY FIELD CONDITIONS AND DIMENSIONS TO THE ARCHITECT, OWNER AND OWNER'S CONTRACTORS
UPON REQUEST
5. G.C. SHALL BE RESPONSIBLE FOR ALL PREPARATION WORK REQUIRED TO INSTALL NEW FLOORING TO MANUFACTURER'S
SPECIFICATIONS
6. G.C. TO COORDINATE WITH OWNER'S VENDORS TO ALLOW FOR PROPER INSTALLATION OF ALL OWNER SUPPLIED ITEMS.
G.C. TO SCHEDULE DELIVERY/ INSTALLATION DATES AT THE BEGINNING OF THE JOB TO GUARANTEE COMPLIANCE WITH
CONSTRUCTION SCHEDULE
7. WHEN IN DOUBT, CONSULT WITH ARCHITECT/OWNER PRIOR TO ANY ACTION
GENERAL NOTES:
1. ALL WORK SHALL CONFORM TO MASSACHUSETTS BUILDING CODE AND ALL FEDERAL, STATE, AND TOWN LAWS, CODES, AND REGULATIONS
AS EACH MAY APPLY.
2. THE TOTAL LIABILITY OF SL HAUS GROUP FOR ANY CLAIMS ARISING OUT OF THE SERVICES PERFORMED UNDER THIS CONTRACT SHALL BE
LIMITED TO A MAXIMUM OF THE NET FEES RECEIVED BY SL HAUS GROUP.
3. ALL EXISTING CONDITIONS MUST BE VERIFIED IN FIELD. IF DISCREPANCIES ARE FOUND, THEY HAVE TO BE REPORTED TO THE ARCHITECT
PRIOR TO START OF WORK. OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND OR THE
SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE START OF SUCH WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING AND WORK OF ALL TRADES AND SHALL CHECK ALL
DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT AND SHALL BE RESOLVED PRIOR TO
PROCEEDING WITH THE WORK.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BUT NOT LIMITED TO BRACING AND SHORING.
6. THE CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR SHALL
ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION, INCLUDING THE
SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS.
7. ALL WORK SHALL BE PERFORMED IN A FIRST CLASS AND WORKMANLIKE MANNER IN CONFORMITY WITH THE PLANS AND SPECIFICATIONS,
AND SHALL BE IN GOOD USABLE CONDITION AT THE COMPLETION OF THE PROJECT.
8. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, UTILITY LOCATIONS AND STRUCTURE PLACEMENT, PRIOR TO START OF
THE WORK. THE CONTRACTOR WILL OBSERVE ALL POSSIBLE PRECAUTIONS TO AVOID DAMAGE TO SAME. ANY DAMAGE TO EXISTING
STRUCTURES AND UTILITIES, WHETHER SHOWN OR NOT ON THE DRAWINGS, SHALL BE REPAIRED OR REPLACED AT THE CONTRACTOR'S
EXPENSE.
9. PRIOR TO BIDDING THE WORK THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY SATISFY HIMSELF AS TO THE ACTUAL
CONDITIONS AND QUANTITIES, IF ANY. NO CLAIM AGAINST THE OWNER OR ARCHITECT WILL BE ALLOWED FOR ANY EXCESS OR DEFICIENCY
THEREIN, ACTUAL OR RELATIVE.
10. CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION AND RELOCATION WORK, IF ANY.
1. ALL LOADS AND LOADING CONDITIONS ARE PER IRC 2015 (9TH EDITION OF MASSACHUSETTS BUILDING CODE).
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS.
3. CONCRETE SHALL BE FC=3000 PSI, MIN. 5-7% AIR ENTRAINED.
4. FOUNDATION DESIGNED BASED ON ASSUMED ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF.
5. ALL EXTERIOR FOUNDATIONS SHALL BE A MIN. 4'-0" BELOW FINISHED GRADE.
6. NO FOUNDATIONS OF SLAB SHALL BE PLACED IN WATER OR FROZEN GROUND.
7. BASEMENT FOUNDATION WALLS ARE NOT DESIGNED TO BE FREE STANDING. PROVIDE ADEQUATE BRACING PRIOR TO BACKFILL; OR
BACKFILL AFTER FIRST FLOOR FRAMING HAS BEEN INSTALLED.
8. ALL REBAR SHALL BE FY=60 KSI.
9. ALL EXTERIOR WALLS SHALL BE 2X6 @ 16" O.C.
10. ALL MEMBERS DESIGNATED AS 1.75"X_" SHALL BE LVL BEAMS.
11. ALL MEMBERS DESIGNATED AS 2X_ SHALL BE DIMENSIONAL LUMBER.
12. ALL DIMENSIONAL LUMBER SHALL BE SPRUCE-PINE-FIR:
12.1 FB=875 PSI
12.2 FV=135 PSI
12.3 FCPAR=425 PSI
12.4 NO.1/NO.2 OR BETTER
13. LVL PLIES SHALL BE FB=3100 PSI, PSL'S SHALL BE FB=2650 PSI, MIN.
14. ALL HEADER SIZES SHALL BE IN ACCORDANCE WITH TABLES 602.7(1), 602.7(2) AND 602.7(3) OF 2015 IRC, U.N.O.
15. NUMBER OF JACK STUDS SHALL BE IN ACCORDANCE WITH TABLES 602.7(1) AND 602.7(2) OF 2015 IRC, U.N.O.
16. EXTERIOR WALLS SHALL BE SHEATHED W/7/16" PLYWOOD OR OSB, U.N.O.
17. ALL FLOORS AND ROOFS SHALL BE SHEATHED W23/32" PLYWOOD OR OSB, U.N.O. ALL LVL HEADERS SHALL BE SUPPORTED BY 4X6 PSL
POSTS, U.N.O.
18. ALL LVL GIRDERS AND HEADERS SHALL BE SUPPORTED BY 4X6 PSL POSTS, U.N.O.
19. APPLY (2) 2X JOISTS UNDER NEW PARTITION WALLS WHICH ARE PARALLEL TO FRAMING.
20. PROVIDE BLOCKING UNDER PARTITION WALLS WHICH ARE PERPENDICULAR TO DIRECTION OF FRAMING.
STRUCTURAL NOTES:
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
1" = 1'-0"
A0.1
GENERAL
NOTES
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
No. Description Date
GENERAL CONSTRUCTION NOTES
1. ALL WORK SHALL CONFORM TO MASSACHUSETTS BUILDING CODE AND ALL APPLICABLE FEDERAL, STATE, & TOWN LAWS,
ORDINANCES, CODES, AND REGULATIONS.
2. ALL EXISTING CONDITIONS MUST BE VERIFIED IN FIELD. CONTRACTOR IS TO STOP WORK AND IMMEDIATELY INFORM ARCHITECT
AND STRUCTURAL ENGINEER UPON DISCOVERY OF ANY SIGNIFICANT & CONSEQUENTIAL DISCREPANCY BETWEEN EXISTING
CONDITIONS AND DESIGN DRAWINGS.
3. DISCREPANCIES OR CONFLICTS BETWEEN ARCHITECT'S AND STRUCTURAL ENGINEER'S DRAWINGS -SHOULD THEY BE FOUND TO
EXIST -ARE NOT TO BE RESOLVED BY EITHER ARCHITECT NOR ENGINEER ALONE. CONTRACTOR IS INSTEAD TO STOP WORK AND
NOTIFY BOTH ARCHITECT AND ENGINEER OF CONFLICT AT ONCE, PROCEEDING ONLY ONCE BOTH PARTIES HAVE APPROVE A
COMMON RESOLUTION. SIMILARLY, CONTRACTOR SHALL NOT PROCEED WITH ANY WORK DISCOVERED TO BE IN CONFLICT. (I.E.
WORK DESCRIBED BY EITHER ARCHITECT OR ENGINEER THAT CANNOT BE PRACTICABLY CONSTRUCTED IN UNION WITH OTHER
DESCRIBED WORK.)
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING AND WORK OF ALL TRADES.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES OF THE WORK. THIS INCLUDES BUT IS NOT LIMITED TO BRACING AND SHORING.
6. THE CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR
SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION,
INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS.
7. ALL WORK SHALL BE PERFORMED IN A FIRST-CLASS AND WORKMANLIKE MANNER IN CONFORMITY WITH THE SPECIFICATIONS
DRAWINGS & DOCUMENTS AND SHALL BE IN GOOD USABLE CONDITION AT THE COMPLETION OF THE WORK.
8. PRIOR TO BIDDING THE WORK, THE CONTRACTOR SHALL VISIT THE SITE AND INDEPENDENTLY VERIFY EXISTING CONDITIONS AND
QUANTITIES. NO CLAIM AGAINST THE OWNER OR ENGINEER WILL BE ALLOWED FOR ANY EXCESS OR DEFICIENCY THEREIN, ACTUAL
OR RELATIVE.
9. THE CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS INCLUDING UTILITY LOCATIONS, ELECTRICAL PANEL
LOCATIONS, BEARING WALL LOCATIONS, AND OTHER RELAVENT INFORMATION PRIOR TO START OF THE WORK.
10. CONTRACTOR WILL OBSERVE ALL STRICT AND PROFESSIONAL PRECAUTIONS NECESSARY TO AVOID INFLICTING ACCIDENTAL
DAMAGE TO EXISTING HOUSE. ANY DAMAGE INFLICTED TO THE EXISTING ARCHITECTURE, STRUCTURE, OR UTILITY SERVICE MUST
BE REPAIRED AT CONTRACTOR'S EXPERIENCE.
LIFE SAFETY LEGEND
CEILING SURFACE-MOUNTED COMBINED SMOKE &
CARBON MONOXIDE DETECTOR W/ AUDIO/VISUAL
ALARM, HARD-WIRED
NOTE: DEVICES TO COMPLY W/ NFPA RULE 72®,
MOST CURRENT EDITION
SYMBOL DESCRIPTION
EXISTING TO REMAIN
NEW
PHASING LEGEND
STRUCTURAL NOTES
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. STRUCTURAL DRAWING DIMENSIONS ARE TAKEN
FROM FACE OF STRUCTURAL MEMBER U.N.O.
2. ALL LOADS AND LOADING CONDITIONS ARE TO ACCORD WITH INTERNATIONAL CODE COUNCIL
INTERNATIONAL RESIDENTIAL CODE AND MASSACHUSETTS BUILDING CODE 9TH EDITION.
3. CONTRACTOR SHALL STOP WORK AND IMMEDIATELY INFORM ARCHITECT UPON DISCOVERY OF ANY
CONFLICT BETWEEN ARCHITECTURAL AND ENGINEERING DRAWINGS.
4. ALL DIMENSIONAL LUMBER MUST BE OF CONSTRUCTION GRADE OR BETTER.
SD
TO BE DEMOLISHED
D1
D2
D3
D4
D5
D6
DEMOLITION LEGEND
DEMOLISH EXISTING WALL
REMOVE EXISTING DOOR, HARDWARE AND FRAME
REMOVE EXISTING WINDOW, HARDWARE AND FRAME
DEMOLISH EXISTING DECK AS NEEDED
REMOVE EXISTING FLOOR AND FLOOR STRUCTURE AS REQ.
DEMOLISH EXISTING STAIR
DEMOLITION LEGEND
D7 REMOVE EXISTING PLUMBING FIXTURES
D8 REMOVE CABINETS & COUTERTOPS
D9 DEMOLISH EXISTING ROOFING AND STRUCTURE
(EXISTING OVERALL)
+/- 15'-7 1/2"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
3
'
-
9
1
/
2
"
2' - 2"5'-10"7'-7 1/2"
(EXISTING OVERALL)
+/- 22'-0"
2'-3 1/2"
3'
-
1
0
"
8'
-
0
"
UNFINISHED
BASEMENT
8'
-
9
"
25
'
-
0
"
3'
-
2
1
/
2
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
6
'
-
1
1
1
/
2
"
+/- 6' - 4 1/2"
DN
22'-10"
10
'
-
0
1
/
2
"
10'-11"
6'-6"2'-1"
5'-2"10'-9"
2'-2"
DN
UP
KITCHEN
BEDROOM
LIVING
ROOM
MAIN ENTRY
MUD
BATH
8'
-
0
"
6'-0"
3'
-
0
"
OPENING
3'-0"
5'-0"
3'
-
0
"
2'
-
0
"
3'
-
0
1
/
2
"
2'
-
0
"
4'-4 1/2"4'-0"
10'-0"
2'-5"2'-6"
11
'
-
0
"
7'-5 1/2"
(EXISTING OVERALL)
+/- 23'-8 1/2"
M
3-0
Y
2-6
4'
-
1
"
137
3'
-
0
"
16
'
-
8
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
8
'
-
7
"
10
'
-
0
1
/
2
"
11
'
-
0
"
12
'
-
1
1
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
5
'
-
7
"
BU
I
L
T
-IN
CLOSET
B
5-0
U
2-8
(EXISTING OVERALL)
17'-2"
3'
-
0
"
DN
DN
2'
-
8
"LAUNDRY
24
'
-
3
1
/
2
"
9'-10"
OFFICE
BEDROOM
6'
-
7
1
/
2
"
2'
-
4
1
/
2
"
11
'
-
1
1
"
5'
-
0
"
CLOSET BATH
CL
O
S
E
T
3'
-
6
"
10
'
-
0
"
8'
-
1
0
1
/
4
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
35
'
-
7
"
(EXISTING OVERALL)
23'-8 1/2"
10
'
-
1
1
"
24
'
-
8
"
7'-5"
2'
-
6
3
/
4
"
6'-6 1/2"
U
2-8
T
2-6
U
2-8
U
2-8
T
2-6
DN
137
137
137
137
(EXISTING OVERALL)
17'-2"
HA
L
L
W
A
Y
137
137
8'-6 1/4"
CLOSET
D
4-0
(OPENING)
5'-5 1/2"
PROPOSED DORMER WALL
ABOVE; REFER TO PROPOSED
ELEVATIONS (TYP.)36" RAILING
3X5
PRIMARY
BATH
PRIMARY
BEDROOM
4'
-
0
"
10'-6"4'-0"
E
2-8
E
2-8
CLOSET
7'-7"
5'
-
7
"
0'2'4'8'16'
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
1/4" = 1'-0"
A1.0
PROPOSED
FLOOR PLANS
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
No. Description Date
1/4" = 1'-0"A1.0
1 PROPOSED BASEMENT
1/4" = 1'-0"A1.0
2 PROPOSED FIRST FLOOR
1/4" = 1'-0"A1.0
3 PROPOSED SECOND FLOOR
N O T F O R C O N S T R U C T I O N
---S C H E M A T I C R E V I E W ---
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
137
M
3-0
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
(O
V
E
R
A
L
L
H
E
I
G
H
T
)
+/
-
2
4
'
-
4
"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(G
R
A
D
E
)
3'
-
6
"
PROPOSED FLAT ROOF;
REFER TO PROPOSED
PLAN(S) (TYP.)
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
137
137
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
H
E
I
G
H
T
)
24
'
-
4
"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(G
R
A
D
E
)
3'
-
6
"
PROPOSED FLAT ROOF;
REFER TO PROPOSED
PLAN(S) (TYP.)
137 137
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
137
PROPOSED FLAT ROOF;
REFER TO PROPOSED
PLAN(S) (TYP.)
(G
R
A
D
E
3'
-
6
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
H
E
I
G
H
T
)
24
'
-
4
"
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(G
R
A
D
E
)
3'
-
6
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
H
E
I
G
H
T
)
24
'
-
4
"
137
PROPOSED FLAT ROOF;
REFER TO PROPOSED
PLAN(S) (TYP.)
GENERAL CONSTRUCTION NOTES
1. ALL WORK SHALL CONFORM TO MASSACHUSETTS BUILDING CODE AND ALL APPLICABLE FEDERAL, STATE, & TOWN LAWS,
ORDINANCES, CODES, AND REGULATIONS.
2. ALL EXISTING CONDITIONS MUST BE VERIFIED IN FIELD. CONTRACTOR IS TO STOP WORK AND IMMEDIATELY INFORM ARCHITECT
AND STRUCTURAL ENGINEER UPON DISCOVERY OF ANY SIGNIFICANT & CONSEQUENTIAL DISCREPANCY BETWEEN EXISTING
CONDITIONS AND DESIGN DRAWINGS.
3. DISCREPANCIES OR CONFLICTS BETWEEN ARCHITECT'S AND STRUCTURAL ENGINEER'S DRAWINGS -SHOULD THEY BE FOUND TO
EXIST -ARE NOT TO BE RESOLVED BY EITHER ARCHITECT NOR ENGINEER ALONE. CONTRACTOR IS INSTEAD TO STOP WORK AND
NOTIFY BOTH ARCHITECT AND ENGINEER OF CONFLICT AT ONCE, PROCEEDING ONLY ONCE BOTH PARTIES HAVE APPROVE A
COMMON RESOLUTION. SIMILARLY, CONTRACTOR SHALL NOT PROCEED WITH ANY WORK DISCOVERED TO BE IN CONFLICT. (I.E.
WORK DESCRIBED BY EITHER ARCHITECT OR ENGINEER THAT CANNOT BE PRACTICABLY CONSTRUCTED IN UNION WITH OTHER
DESCRIBED WORK.)
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING AND WORK OF ALL TRADES.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES OF THE WORK. THIS INCLUDES BUT IS NOT LIMITED TO BRACING AND SHORING.
6. THE CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR
SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION,
INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS.
7. ALL WORK SHALL BE PERFORMED IN A FIRST-CLASS AND WORKMANLIKE MANNER IN CONFORMITY WITH THE SPECIFICATIONS
DRAWINGS & DOCUMENTS AND SHALL BE IN GOOD USABLE CONDITION AT THE COMPLETION OF THE WORK.
8. PRIOR TO BIDDING THE WORK, THE CONTRACTOR SHALL VISIT THE SITE AND INDEPENDENTLY VERIFY EXISTING CONDITIONS AND
QUANTITIES. NO CLAIM AGAINST THE OWNER OR ENGINEER WILL BE ALLOWED FOR ANY EXCESS OR DEFICIENCY THEREIN, ACTUAL
OR RELATIVE.
9. THE CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS INCLUDING UTILITY LOCATIONS, ELECTRICAL PANEL
LOCATIONS, BEARING WALL LOCATIONS, AND OTHER RELAVENT INFORMATION PRIOR TO START OF THE WORK.
10. CONTRACTOR WILL OBSERVE ALL STRICT AND PROFESSIONAL PRECAUTIONS NECESSARY TO AVOID INFLICTING ACCIDENTAL
DAMAGE TO EXISTING HOUSE. ANY DAMAGE INFLICTED TO THE EXISTING ARCHITECTURE, STRUCTURE, OR UTILITY SERVICE MUST
BE REPAIRED AT CONTRACTOR'S EXPERIENCE.
LIFE SAFETY LEGEND
CEILING SURFACE-MOUNTED COMBINED SMOKE &
CARBON MONOXIDE DETECTOR W/ AUDIO/VISUAL
ALARM, HARD-WIRED
NOTE: DEVICES TO COMPLY W/ NFPA RULE 72®,
MOST CURRENT EDITION
SYMBOL DESCRIPTION
EXISTING TO REMAIN
NEW
PHASING LEGEND
STRUCTURAL NOTES
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. STRUCTURAL DRAWING DIMENSIONS ARE TAKEN
FROM FACE OF STRUCTURAL MEMBER U.N.O.
2. ALL LOADS AND LOADING CONDITIONS ARE TO ACCORD WITH INTERNATIONAL CODE COUNCIL
INTERNATIONAL RESIDENTIAL CODE AND MASSACHUSETTS BUILDING CODE 9TH EDITION.
3. CONTRACTOR SHALL STOP WORK AND IMMEDIATELY INFORM ARCHITECT UPON DISCOVERY OF ANY
CONFLICT BETWEEN ARCHITECTURAL AND ENGINEERING DRAWINGS.
4. ALL DIMENSIONAL LUMBER MUST BE OF CONSTRUCTION GRADE OR BETTER.
SD
TO BE DEMOLISHED
D1
D2
D3
D4
D5
D6
DEMOLITION LEGEND
DEMOLISH EXISTING WALL
REMOVE EXISTING DOOR, HARDWARE AND FRAME
REMOVE EXISTING WINDOW, HARDWARE AND FRAME
DEMOLISH EXISTING DECK AS NEEDED
REMOVE EXISTING FLOOR AND FLOOR STRUCTURE AS REQ.
DEMOLISH EXISTING STAIR
DEMOLITION LEGEND
D7 REMOVE EXISTING PLUMBING FIXTURES
D8 REMOVE CABINETS & COUTERTOPS
D9 DEMOLISH EXISTING ROOFING AND STRUCTURE
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
1/4" = 1'-0"
A2.0
PROPOSED
EXTERIOR
ELEVATIONS
TM/JL
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
0'2'4'8'16'
No. Description Date
1/4" = 1'-0"A2.0
1 PROPOSED FRONT ELEVATION
1/4" = 1'-0"A2.0
2 PROPOSED LEFT ELEVATION
1/4" = 1'-0"A2.0
3 PROPOSED REAR ELEVATION
1/4" = 1'-0"A2.0
4 PROPOSED RIGHT ELEVATION
N O T F O R C O N S T R U C T I O N
---S C H E M A T I C R E V I E W ---
1'
-
4
"
1' - 4"
CONTINUOUS
POUR
CONCRETE
ANCHOR BOLTS
RE-BAR
8"
COMPACTED EARTH
BACKFILL
CRUSHED ROCK
10".
1' - 8".
4"
.
6"
.
2X6 STUD WALL
3/4" T+G PLYWOOD SUBFLOOR
SILL PLATES WITH SEALER
GALVANIZED ANCHOR
BOLTS AT 4'-0" O.C.
R15 POLYISOCYANURATE
INSULATION UNDERNEATH SLAB
INSULTARP VAPOR BARRIER
4" CONCRETE SLAB ON 6 MIL.
POLY VAPOR BARRIER ON 6"
COMPACTED CRUSHED STONE.FOOTING DOWELS
@ 16" O.C.
4" PERFORATED
PVC FOUNDATION
DRAIN
BACKFILL
MESH SCREENING
R15 POLYISOCYANURATE
INSULATION
DAMP PROOFING
SLOPE GRADE AWAY FROM BUILDING
5/8" ZIP SHEATHING,
OVERLAP FOUNDATION
1" MIN.
1'
-
0
"
.
B.O. FOOTING
ROUGH FIRST FLOOR
TOP OF CONCRETE
TOP OF SLAB
EXISTING
FOUNDATION
DEMO EXISTING
VINYL SIDING AT
CONNECTION
TYPE X-GYP. BOARD
6" STUD W/
BATT INSULATION
TYPE X-GYP. BOARD
NEW FOOTING
BEYOND
NEW CONSTRUCTIONEXISTING
6" GRAVEL
MATCH EXISTING
UNDERLAYMENT
NEW PART TO ABBUTT
EXISTING CONSTRUCTION.
VIF IF LEDGE OF EXISTING IS
LONG ENOUGH
FOR NEW PORTION TO REST
ON SLAB.
EXISTING
FLOOR
EXISTING FOUNDATION
1' - 8"
NEW FOUNDATION
FOOTING BELOW
ONE-HR RATED
PARTITION
THREADED
ROD
R 15 POLYISOCYANURATE
INSULATION
DAMP-PROOFING
10" FOUNDATION WALLS.
1/2" AIR SPACE
2 X 4 WOOD STUD@ 16 O.C.
3.5" MINERAL WOOL BATT
INSULATION
5/8" GYPSUM WALL BOARD
HOLD-DOWN OR
SIMILAR TENSION
DEVICE
DECK JOIST
THREADED ROD
FLOOR JOIST
2X12 SOLE PLATE
FLOOR SHEATHING NAILING
AT 6" MAX. ON-CENTER TO
JOISTS WITH HOLD-DOWN
EXTENT OF BLOCKING
6 FT. MIN.
ATTACH BLOCKING TO DECK W/
10D NAILS AT 4" O.C. STAGGERED
MINIMUM 1 1/2" THICK
BLOCKING. BLOCKS
MUST FILL BAY AND
FIT SNUGLY
FLOOR JOIST
(I-JOIST OR
SOLID JOIST)
JOIST HANGER (FOR
NON-LEDGER DECK,
BLOCKING, OR FRAMING
ANGLE)
FASTENERS PER TABLE 5
THREADED ROD, MAY BE
SLOPED UP TO 1:12 AWAY
FROM THE HOUSE
HOLD-DOWN OR SIMILAR
TENSION DEVICE
DECK JOIST
BEAM & POST FOR
NON-LEDGER DECKS
INSULATION R-49
ASPHALT SHINGLES
5/8" PLYWOOD SHEATHINGMETAL DRIP EDGE
1x4 ON 1x10
FASCIA BOARDS
JOIST HANGER
1x3 STRAPPING
SOFFIT BOARD
2X8 LEDGER
1x3 STRAPPING
GWB CEILING
SELF ADHERING RUBBERIZED
ASPHALT WATERPROOFING
MEMBRANE
ICE AND WATER SHIELD-4'
ABOVE ROOF EDGE
CONTINUOUS EXTERIOR
INSULATION
1' - 6"
5/8" GYPSUM WALLBOARD
2X4 WOOD STUDS
@ 16" O.C.
5/8" GYPSUM WALLBOARD
SOUND INSULATION
5/8" GYPSUM WALLBOARD
2X6 WOOD STUDS
@ 16" O.C.
5/8" GYPSUM WALLBOARD
5" MINERAL WOOL
BATT INSULATION
5/8" TYPE "X" GYPSUM
WALLBOARD
2X6 WOOD STUDS
@ 16" O.C.
5/8" TYPE "X" GYPSUM
WALLBOARD
SOUND INSULATION
FINISH FLOOR
5 1/2" WOOD STUDS, 16" O.C.
MAX. WITH R-20 INSULATION
1/2" EXTERIOR GRADE
PLYWOOD (ZIP SYSTEM)
BUILDING WRAP (OR TAPE ZIP
SYSTEM PER
MANUFACTURER'S
INSTRUCTIONS TO CREATE
AIR BARRIER)
UNDERSIDE OF STRUCTURE
5 1/2" STUD
IN
T
E
R
I
O
R
CEMENTITIOUS CLAPBOARDS
(MATCH EXISTING)
1/2" GYPSUM WALL BOARD PT. WD. POST
SEAL ALL AROUND
CONCRETE STEP
POST HOLDER DOWEL
IN MORTAR-FILLED 3/4"
CORE DRILLED INTO
CONCRETE
STL. POST HOLDER:
SIMPSON® "STRONG-
TIE"® "W.U.B." OR APP.
EQ.
PVC ENCLOSURED
NEW 2X4'S @16" O.C
1/2" DRYWALL
RIGID INSULATION TO MEET
R-21
1" GAP
WD. SILL
TILE FLOORING
EX. SLAB
EX. FOUNDATION
WALL
3 1/2"
METAL DRIP EDGE
1x4 ON 1x12
1x3 STRAPPING
SOFFIT BOARD
JOIST HANGER
CONTINUOUS EXTERIOR INSULATION
DOUBLE 2x6 PLATE
SHEATING
WATER/VAPOR BARRIER
(SEE FLOOR PLANS FOR NOTES
ASPHALT SHINGLES
SELF ADHERING RUBBERIZED ASPHALT
WATERPROOFING MEMBRANE
5/8" PLYWOOD SHEATHING
RAFTERS (SEE STRUCTURAL)
INSULATION
ICE AND WATER SHIELD-4' ABOVE
ROOF EDGE
RIM BOARD
GUTTER
1x3 STRAPPING
GWB CEILING
SIDING PER ELEVATIONS
1' - 6"
1' - 6"METAL DRIP EDGE
1X4 ON 1X10 PVC
OR BOREL TRIM
1x3 STRAPPING
SOFFIT BOARD
JOIST HANGER
1" RIGID INSULATION
DOUBLE 2x6 PLATE
PLYWOOD SHEATING
WATER/VAPOR BARRIER
(SEE FLOOR PLANS FOR NOTES
HIGH HEAT METAL ROOFING MENBRANE
1/2" POLY-ISO
5/8" CDX PLYWOOD SHEATHING
INSULATION R-49 ROOF OR CEILING
ALUM FACE + TAPE EDGES WITH ALUM TAPE
RIM BOARD
ALUMINUM GUTTER
1x3 WD
STRAPPING
GWB CEILING
PLASTER / PAINTT
1/2" GWB
CAVITY INSULATION
2X6 WD STUDS
SEALANT
INTERIOR
FINISH
( SEE STRUCTURAL FOR SIZING)
2X2 OR 2X4 BATTEN ( PURLINS)
5/8" CDX SHEATING
STRUCTURE SEPARATING MENBRANE DORKEN OR EQUAL
ALUMINUM STANDING SEAM ROOF SYSTEM WITH DREXEL METALS
OR EQUAL WITH HIDDEN PANEL CLIPS
VENT
7
1
/
2
"
VERTICAL SIDING
1' - 6"
2x6 @ 16" O.C. SEE
STRUCTURAL FOR DETAILS.
1x8 TRIM BOARD
1x4 TRIM
BOARD
5" GUTTER
JOIST HANGERS
LEDGER
ICE AND WATER SHIELD
DRIP EDGE
1x4 STRIP SHEATHING
2x8 RAFTERS. SEE
STRUCTURAL
ROOFING PAPER DRAINAGE
PLANE INSTALLED SHINGLE
FASHION
METAL ROOF
BLOCKING
RIM JOIST. SEE STRUCTURAL
FLOOR JOISTS.
SEE STRUCTURAL
METAL FLASHING
CONTINUOUS VENT
NAIL
BOLTS
LAGER BOLTS
HEADER
2' - 0"
5"
FLASHING
CANT STRIP
3/4" PLYWOOD SHEATHING
FLASHING
1x4 ON 1x10 FASCIA BOARDS
MESH REINFORCED EPDM
ICE AND WATER SHIELD
CABLE RAIL BALUSTRADE
DECKING MATERIAL
SLIDING DOOR
1/2" FIBER BOARD OR SUBSTRATE
2x SLEEPER 16" O.C
TRIM
SEE STRUCTURAL
4"
ASPHALT
SHINGLES
ASPHALT 1.5-2" AIRSPACE
WITH POLY BAFFLE
DRYWALL
GUTTER
FASCIA
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
As indicated
A3.0
TYPICAL
PROJECT
DETAILS
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
No. Description Date
3/4" = 1'-0"A3.0
1 GARAGE FOOTING
1/4" = 1'-0"A3.0
2 FOUNDATION DETAIL - BASEMENT
3/8" = 1'-0"A3.0
4 FOUNDATION ABBUTMENT DETAIL
1/2" = 1'-0"A3.0
5 FOUNDATION ABBUTMENT PLAN CALLOUT
3/4" = 1'-0"A3.0
6 10" FOUNDATION WALL
3/4" = 1'-0"A3.0
7 DECK LATERAL-LOAD BRACING(JOISTS PARALLEL TO DECK JOISTS)
1/2" = 1'-0"A3.0
8 DECK LATERAL-LOAD BRACING (JOISTS PERPENDICULAR TO DECK JOISTS)
3/4" = 1'-0"A3.0
10 TYP. FLAT ROOF RAKE DETAIL
1/2" = 1'-0"A3.0
11 2X4 INTERIOR PARTITION (TYPICAL)
1/2" = 1'-0"A3.0
12 2X6 1HR RATED WALL
1/2" = 1'-0"A3.0
13 2X6 PLUMBING WALL
3/4" = 1'-0"A3.0
14 LAP SIDING.
1 1/2" = 1'-0"A3.0
15 TYP. WOOD POST IN POST HOLDER
3/8" = 1'-0"A3.0
16 TYP. BASEMENT STUD WALL
3/4" = 1'-0"A3.0
17 TYP. EAVE DETAIL
3/4" = 1'-0"A3.0
18 TYP. EAVE DETAIL METAL ROOF
3/4" = 1'-0"A3.0
19 TYP. SMALL ROOF
3/4" = 1'-0"A3.0
20 TYP. ROOF DECK DETAIL
1/2" = 1'-0"A3.0
21 CATHEDRAL CEILING DETAIL
UP
UP
UP
GENERAL CONSTRUCTION NOTES
1. ALL WORK SHALL CONFORM TO MASSACHUSETTS BUILDING CODE AND ALL APPLICABLE FEDERAL, STATE, & TOWN LAWS,
ORDINANCES, CODES, AND REGULATIONS.
2. ALL EXISTING CONDITIONS MUST BE VERIFIED IN FIELD. CONTRACTOR IS TO STOP WORK AND IMMEDIATELY INFORM ARCHITECT
AND STRUCTURAL ENGINEER UPON DISCOVERY OF ANY SIGNIFICANT & CONSEQUENTIAL DISCREPANCY BETWEEN EXISTING
CONDITIONS AND DESIGN DRAWINGS.
3. DISCREPANCIES OR CONFLICTS BETWEEN ARCHITECT'S AND STRUCTURAL ENGINEER'S DRAWINGS -SHOULD THEY BE FOUND TO
EXIST -ARE NOT TO BE RESOLVED BY EITHER ARCHITECT NOR ENGINEER ALONE. CONTRACTOR IS INSTEAD TO STOP WORK AND
NOTIFY BOTH ARCHITECT AND ENGINEER OF CONFLICT AT ONCE, PROCEEDING ONLY ONCE BOTH PARTIES HAVE APPROVE A
COMMON RESOLUTION. SIMILARLY, CONTRACTOR SHALL NOT PROCEED WITH ANY WORK DISCOVERED TO BE IN CONFLICT. (I.E.
WORK DESCRIBED BY EITHER ARCHITECT OR ENGINEER THAT CANNOT BE PRACTICABLY CONSTRUCTED IN UNION WITH OTHER
DESCRIBED WORK.)
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING AND WORK OF ALL TRADES.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES OF THE WORK. THIS INCLUDES BUT IS NOT LIMITED TO BRACING AND SHORING.
6. THE CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR
SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION,
INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS.
7. ALL WORK SHALL BE PERFORMED IN A FIRST-CLASS AND WORKMANLIKE MANNER IN CONFORMITY WITH THE SPECIFICATIONS
DRAWINGS & DOCUMENTS AND SHALL BE IN GOOD USABLE CONDITION AT THE COMPLETION OF THE WORK.
8. PRIOR TO BIDDING THE WORK, THE CONTRACTOR SHALL VISIT THE SITE AND INDEPENDENTLY VERIFY EXISTING CONDITIONS AND
QUANTITIES. NO CLAIM AGAINST THE OWNER OR ENGINEER WILL BE ALLOWED FOR ANY EXCESS OR DEFICIENCY THEREIN, ACTUAL
OR RELATIVE.
9. THE CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS INCLUDING UTILITY LOCATIONS, ELECTRICAL PANEL
LOCATIONS, BEARING WALL LOCATIONS, AND OTHER RELAVENT INFORMATION PRIOR TO START OF THE WORK.
10. CONTRACTOR WILL OBSERVE ALL STRICT AND PROFESSIONAL PRECAUTIONS NECESSARY TO AVOID INFLICTING ACCIDENTAL
DAMAGE TO EXISTING HOUSE. ANY DAMAGE INFLICTED TO THE EXISTING ARCHITECTURE, STRUCTURE, OR UTILITY SERVICE MUST
BE REPAIRED AT CONTRACTOR'S EXPERIENCE.
LIFE SAFETY LEGEND
CEILING SURFACE-MOUNTED COMBINED SMOKE &
CARBON MONOXIDE DETECTOR W/ AUDIO/VISUAL
ALARM, HARD-WIRED
NOTE: DEVICES TO COMPLY W/ NFPA RULE 72®,
MOST CURRENT EDITION
SYMBOL DESCRIPTION
EXISTING TO REMAIN
NEW
PHASING LEGEND
STRUCTURAL NOTES
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. STRUCTURAL DRAWING DIMENSIONS ARE TAKEN
FROM FACE OF STRUCTURAL MEMBER U.N.O.
2. ALL LOADS AND LOADING CONDITIONS ARE TO ACCORD WITH INTERNATIONAL CODE COUNCIL
INTERNATIONAL RESIDENTIAL CODE AND MASSACHUSETTS BUILDING CODE 9TH EDITION.
3. CONTRACTOR SHALL STOP WORK AND IMMEDIATELY INFORM ARCHITECT UPON DISCOVERY OF ANY
CONFLICT BETWEEN ARCHITECTURAL AND ENGINEERING DRAWINGS.
4. ALL DIMENSIONAL LUMBER MUST BE OF CONSTRUCTION GRADE OR BETTER.
SD
TO BE DEMOLISHED
D1
D2
D3
D4
D5
D6
DEMOLITION LEGEND
DEMOLISH EXISTING WALL
REMOVE EXISTING DOOR, HARDWARE AND FRAME
REMOVE EXISTING WINDOW, HARDWARE AND FRAME
DEMOLISH EXISTING DECK AS NEEDED
REMOVE EXISTING FLOOR AND FLOOR STRUCTURE AS REQ.
DEMOLISH EXISTING STAIR
DEMOLITION LEGEND
D7 REMOVE EXISTING PLUMBING FIXTURES
D8 REMOVE CABINETS & COUTERTOPS
D9 DEMOLISH EXISTING ROOFING AND STRUCTURE
15' - 7 1/2"
6' - 4 1/2"
8'
-
9
"
15'-7 1/2"
33
'
-
9
1
/
2
"
2' - 2"
5'-10"
22'-0"
6'-8"
5'
-
8
"
6'
-
1
0
"
8'
-
4
"
9'
-
7
"
6'-8"
2'-3 1/2"
3'
-
1
0
"
UNFINISHED
BASEMENT
22'-10"
5'-1"
7'-2"
10
'
-
0
1
/
2
"
3'
-
3
"
16'-3 1/2"
11
'
-
0
"
6'
-
5
"
3'
-
0
"
6'-6"
5'-2"10'-9"
2'-2"
12
'
-
1
1
"
4'-10"4'-10"
DN
UP
EXISTING
KITCHEN
EXISTING
DINING
EXISTING
LIVING
MAIN ENTRY
SIDE ENTRY
EXISTING
BATH
D1
D2
D7
D1
DEMO
EXISTING
FLOOR
D2
D3
D2
D2D2
D2
12'-9"
3'-0"
24
'
-
3
1
/
2
"
3'
-
8
"
3'-4"
9'
-
9
"
2'
-
6
"
3'
-
0
"
5'-2"
16'-3 1/2"
EXISTING
BEDROOM
D1
D2 D2D2
D2
EXISTING
BEDROOM
DEMO ROOF - PREP FOR
NEW SECOND FLOOR
D3 D3
0'2'4'8'16'
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
1/4" = 1'-0"
D1.0
EXISTING
DEMOLITION
PLANS
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
No. Description Date
1/4" = 1'-0"D1.0
1 EX. BASEMENT FLOOR DEMOLITION PLAN
1/4" = 1'-0"D1.0
2 EX. FIRST FLOOR DEMOLITION PLAN
1/4" = 1'-0"D1.0
3 EX. 2ND FLOOR DEMOLITION PLAN
N O T F O R C O N S T R U C T I O N
---S C H E M A T I C R E V I E W ---
GENERAL CONSTRUCTION NOTES
1. ALL WORK SHALL CONFORM TO MASSACHUSETTS BUILDING CODE AND ALL APPLICABLE FEDERAL, STATE, & TOWN LAWS,
ORDINANCES, CODES, AND REGULATIONS.
2. ALL EXISTING CONDITIONS MUST BE VERIFIED IN FIELD. CONTRACTOR IS TO STOP WORK AND IMMEDIATELY INFORM ARCHITECT
AND STRUCTURAL ENGINEER UPON DISCOVERY OF ANY SIGNIFICANT & CONSEQUENTIAL DISCREPANCY BETWEEN EXISTING
CONDITIONS AND DESIGN DRAWINGS.
3. DISCREPANCIES OR CONFLICTS BETWEEN ARCHITECT'S AND STRUCTURAL ENGINEER'S DRAWINGS -SHOULD THEY BE FOUND TO
EXIST -ARE NOT TO BE RESOLVED BY EITHER ARCHITECT NOR ENGINEER ALONE. CONTRACTOR IS INSTEAD TO STOP WORK AND
NOTIFY BOTH ARCHITECT AND ENGINEER OF CONFLICT AT ONCE, PROCEEDING ONLY ONCE BOTH PARTIES HAVE APPROVE A
COMMON RESOLUTION. SIMILARLY, CONTRACTOR SHALL NOT PROCEED WITH ANY WORK DISCOVERED TO BE IN CONFLICT. (I.E.
WORK DESCRIBED BY EITHER ARCHITECT OR ENGINEER THAT CANNOT BE PRACTICABLY CONSTRUCTED IN UNION WITH OTHER
DESCRIBED WORK.)
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING AND WORK OF ALL TRADES.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS,
TECHNIQUES, SEQUENCES, AND PROCEDURES OF THE WORK. THIS INCLUDES BUT IS NOT LIMITED TO BRACING AND SHORING.
6. THE CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR
SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION,
INCLUDING THE SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL WORKING HOURS.
7. ALL WORK SHALL BE PERFORMED IN A FIRST-CLASS AND WORKMANLIKE MANNER IN CONFORMITY WITH THE SPECIFICATIONS
DRAWINGS & DOCUMENTS AND SHALL BE IN GOOD USABLE CONDITION AT THE COMPLETION OF THE WORK.
8. PRIOR TO BIDDING THE WORK, THE CONTRACTOR SHALL VISIT THE SITE AND INDEPENDENTLY VERIFY EXISTING CONDITIONS AND
QUANTITIES. NO CLAIM AGAINST THE OWNER OR ENGINEER WILL BE ALLOWED FOR ANY EXCESS OR DEFICIENCY THEREIN, ACTUAL
OR RELATIVE.
9. THE CONTRACTOR SHALL FIELD-VERIFY ALL EXISTING CONDITIONS INCLUDING UTILITY LOCATIONS, ELECTRICAL PANEL
LOCATIONS, BEARING WALL LOCATIONS, AND OTHER RELAVENT INFORMATION PRIOR TO START OF THE WORK.
10. CONTRACTOR WILL OBSERVE ALL STRICT AND PROFESSIONAL PRECAUTIONS NECESSARY TO AVOID INFLICTING ACCIDENTAL
DAMAGE TO EXISTING HOUSE. ANY DAMAGE INFLICTED TO THE EXISTING ARCHITECTURE, STRUCTURE, OR UTILITY SERVICE MUST
BE REPAIRED AT CONTRACTOR'S EXPERIENCE.
LIFE SAFETY LEGEND
CEILING SURFACE-MOUNTED COMBINED SMOKE &
CARBON MONOXIDE DETECTOR W/ AUDIO/VISUAL
ALARM, HARD-WIRED
NOTE: DEVICES TO COMPLY W/ NFPA RULE 72®,
MOST CURRENT EDITION
SYMBOL DESCRIPTION
EXISTING TO REMAIN
NEW
PHASING LEGEND
STRUCTURAL NOTES
1. CONTRACTOR SHALL VERIFY ALL DIMENSIONS. STRUCTURAL DRAWING DIMENSIONS ARE TAKEN
FROM FACE OF STRUCTURAL MEMBER U.N.O.
2. ALL LOADS AND LOADING CONDITIONS ARE TO ACCORD WITH INTERNATIONAL CODE COUNCIL
INTERNATIONAL RESIDENTIAL CODE AND MASSACHUSETTS BUILDING CODE 9TH EDITION.
3. CONTRACTOR SHALL STOP WORK AND IMMEDIATELY INFORM ARCHITECT UPON DISCOVERY OF ANY
CONFLICT BETWEEN ARCHITECTURAL AND ENGINEERING DRAWINGS.
4. ALL DIMENSIONAL LUMBER MUST BE OF CONSTRUCTION GRADE OR BETTER.
SD
TO BE DEMOLISHED
D1
D2
D3
D4
D5
D6
DEMOLITION LEGEND
DEMOLISH EXISTING WALL
REMOVE EXISTING DOOR, HARDWARE AND FRAME
REMOVE EXISTING WINDOW, HARDWARE AND FRAME
DEMOLISH EXISTING DECK AS NEEDED
REMOVE EXISTING FLOOR AND FLOOR STRUCTURE AS REQ.
DEMOLISH EXISTING STAIR
DEMOLITION LEGEND
D7 REMOVE EXISTING PLUMBING FIXTURES
D8 REMOVE CABINETS & COUTERTOPS
D9 DEMOLISH EXISTING ROOFING AND STRUCTURE
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
(O
V
E
R
A
L
L
H
E
I
G
H
T
)
+/
-
2
4
'
-
4
"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(G
R
A
D
E
)
3'
-
6
"
D2
D9
PROPOSED DEMOLITION OF EXISTING ROOF
ONLY TO FACILITATE NEW CONSTRUCTION;
REFER TO PROPOSED PLANS (TYP.)
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
H
E
I
G
H
T
)
24
'
-
4
"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(G
R
A
D
E
)
3'
-
6
"
D9
D3
PROPOSED DEMOLITION OF EXISTING ROOF
ONLY TO FACILITATE NEW CONSTRUCTION;
REFER TO PROPOSED PLANS (TYP.)
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
(G
R
A
D
E
3'
-
6
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
H
E
I
G
H
T
)
24
'
-
4
"
D3 D3
D9
PROPOSED DEMOLITION OF EXISTING ROOF
ONLY TO FACILITATE NEW CONSTRUCTION;
REFER TO PROPOSED PLANS (TYP.)
1ST FLOOR
0"
EX. 2ND FLOOR
9' -6"
T.O. RIDGE
20' -10"
AVG. GRADE
-3' -6"
(S
E
C
O
N
D
F
L
O
O
R
)
11
'
-
4
"
(F
I
R
S
T
F
L
O
O
R
)
9'
-
6
"
(G
R
A
D
E
)
3'
-
6
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
H
E
I
G
H
T
)
24
'
-
4
"
D9
PROPOSED DEMOLITION OF EXISTING ROOF
ONLY TO FACILITATE NEW CONSTRUCTION;
REFER TO PROPOSED PLANS (TYP.)
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
1/4" = 1'-0"
D1.1
EX. EXTERIOR
DEMOLITION
ELEVATIONS
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
0'2'4'8'16'
No. Description Date
N O T F O R C O N S T R U C T I O N
---S C H E M A T I C R E V I E W ---
1/4" = 1'-0"D1.1
1 EX. FRONT DEMOLITION ELEVATION
1/4" = 1'-0"D1.1
2 EX. LEFT DEMOLITION ELEVATION
1/4" = 1'-0"D1.1
3 EX. REAR DEMOLITION ELEVATION
1/4" = 1'-0"D1.1
4 EX. RIGHT DEMOLITION ELEVATION
(EXISTING OVERALL)
+/- 15'-7 1/2"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
3
'
-
9
1
/
2
"
2' - 2"5'-10"7'-7 1/2"
(EXISTING OVERALL)
+/- 22'-0"
2'-3 1/2"
UNFINISHED
BASEMENT
8'
-
9
"
25
'
-
0
"
3'
-
2
1
/
2
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
6
'
-
1
1
1
/
2
"
+/- 6' - 4 1/2"
DN
S1.0
4 TYP
EXISTING BEAM ABOVE
SANDWICH WITH NEW
(2) 1.75"X9.5" LVL
EXISTING FRAMING
ABOVE TO REMAIN
REPAIR OR SISTER
ANY BROKEN JOISTS
8'
-
0
"
8'
-
0
"
8'
-
0
"
EXISTING LALLY
COLUMNS
VERIFY CONDITION
EXISTING LALLY
COLUMNS
VERIFY CONDITION
REPLACE EXISTING
COLUMNS WITH NEW LALLY
COLUMNS WITH ISOLATED
FOOTINGS 8' +/-O.C.
EXISTING STAIRS TO
REMAIN
S1.0
3 TYP
3'
-
6
"
3'
-
6
"
PROPOSED BIG
FOOT FOOTINGS
FOR NEW ADDITION
EX
I
S
T
I
N
G
F
O
U
N
D
A
T
I
O
N
T
O
R
E
M
A
I
N
EX
I
S
T
I
N
G
F
O
U
N
D
A
T
I
O
N
T
O
R
E
M
A
I
N
SA
N
D
W
I
C
H
E
X
I
S
T
I
N
G
B
E
A
M
W
/
(2
)
1
.
7
5
"
X
9
.
5
"
L
V
L
22'-10"
JO
I
S
T
S
P
A
N
10
'
-
0
1
/
2
"
6'-6"2'-1"
5'-2"10'-9"
2'-2"
8'
-
0
"
6'-0"
5'-0"
11
'
-
0
"
(EXISTING OVERALL)
+/- 23'-8 1/2"
3'
-
0
"
16
'
-
8
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
8
'
-
7
"
10
'
-
0
1
/
2
"
11
'
-
0
"
12
'
-
1
1
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
+/
-
3
5
'
-
7
"
(EXISTING OVERALL)
17'-2"
EXISTING FRAMING ABOVE
TO REMAIN
REPAIR OR SISTER ANY
BROKEN JOISTS
PROVIDE NEW JOIST
HANGERS AT EACH END
REMOVE EXISTING FRAMING
NEW 2X10 FLOOR JOISTS W/
JOIST HANGERS @ 16" O.C.
SA
N
D
W
I
C
H
E
X
I
S
T
I
N
G
B
E
A
M
W
/
(2
)
1
.
7
5
"
X
9
.
5
"
L
V
L
EXISTING FRAMING ABOVE
TO REMAIN
REPAIR OR SISTER ANY
BROKEN JOISTS
PROVIDE NEW JOIST
HANGERS AT EACH END
SA
N
D
W
I
C
H
E
X
I
S
T
I
N
G
B
E
A
M
W
/
(2
)
1
.
7
5
"
X
9
.
5
"
L
V
L
EXISTING BEAM ABOVE
SANDWICH WITH NEW (2) 1.75"X9.5" LVL
EXISTING FRONT PORCH
REPAIR AS NEEDED
3'
-
0
"
5'-6"
2X8 P.T. DECK JOISTS W/
HANGERS @ 12" O.C.
NEW 2X10 FLOOR
JOISTS @ 16" O.C. W/
JOIST HANGERS
6" PT WOOD POST
SIMPSON STRONG-TIE POST
BASE W/ 1/2" DIAM. GALV.
BOLT W/ MIN. 8" EMBEDMENT
INTO CONCRETE
12" SONOTUBE
BIGFOOT BASE (MODEL BF28)
BOTTOM OF GRADE A MINIMUM
4'-0" BELOW FINISH GRADE 1'
-
0
"
8"
FINISH BASEMENT
FLOOR
(4) #4 BARS EACH WAY W/ MINIMUM
3" CLEARANCE ON BOTTOM & 1.5"
CLEARANCE ON EACH SIDE
CONCRETE FOOTING
STEEL PLATE CENTERED
ON 1/2" GROUT
4" CONCRETE SLAB
6 MIL. POLY VAPOR BARRIER
4" COMPACTED CRUSHED STONE
3.5" STEEL LALLY COLUMN
WOOD BEAM ABOVE
TOP PLACE
GENERAL NOTES:
1. ALL WORK SHALL CONFORM TO MASSACHUSETTS BUILDING CODE AND ALL FEDERAL, STATE, AND TOWN LAWS, CODES, AND REGULATIONS
AS EACH MAY APPLY.
2. THE TOTAL LIABILITY OF SL HAUS GROUP FOR ANY CLAIMS ARISING OUT OF THE SERVICES PERFORMED UNDER THIS CONTRACT SHALL BE
LIMITED TO A MAXIMUM OF THE NET FEES RECEIVED BY SL HAUS GROUP.
3. ALL EXISTING CONDITIONS MUST BE VERIFIED IN FIELD. IF DISCREPANCIES ARE FOUND, THEY HAVE TO BE REPORTED TO THE ARCHITECT
PRIOR TO START OF WORK. OMISSIONS OR CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND OR THE
SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO THE START OF SUCH WORK.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SCHEDULING AND WORK OF ALL TRADES AND SHALL CHECK ALL
DIMENSIONS. ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ARCHITECT AND SHALL BE RESOLVED PRIOR TO
PROCEEDING WITH THE WORK.
5. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE SOLELY RESPONSIBLE FOR THE CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES, INCLUDING BUT NOT LIMITED TO BRACING AND SHORING.
6. THE CONTRACTOR AGREES THAT IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR SHALL
ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR THE JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION, INCLUDING THE
SAFETY OF ALL PERSONS AND PROPERTY, AND THAT THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL
WORKING HOURS.
7. ALL WORK SHALL BE PERFORMED IN A FIRST CLASS AND WORKMANLIKE MANNER IN CONFORMITY WITH THE PLANS AND SPECIFICATIONS,
AND SHALL BE IN GOOD USABLE CONDITION AT THE COMPLETION OF THE PROJECT.
8. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, UTILITY LOCATIONS AND STRUCTURE PLACEMENT, PRIOR TO START OF
THE WORK. THE CONTRACTOR WILL OBSERVE ALL POSSIBLE PRECAUTIONS TO AVOID DAMAGE TO SAME. ANY DAMAGE TO EXISTING
STRUCTURES AND UTILITIES, WHETHER SHOWN OR NOT ON THE DRAWINGS, SHALL BE REPAIRED OR REPLACED AT THE CONTRACTOR'S
EXPENSE.
9. PRIOR TO BIDDING THE WORK THE CONTRACTOR SHALL VISIT THE SITE AND THOROUGHLY SATISFY HIMSELF AS TO THE ACTUAL
CONDITIONS AND QUANTITIES, IF ANY. NO CLAIM AGAINST THE OWNER OR ARCHITECT WILL BE ALLOWED FOR ANY EXCESS OR DEFICIENCY
THEREIN, ACTUAL OR RELATIVE.
10. CONTRACTOR IS RESPONSIBLE FOR ALL DEMOLITION AND RELOCATION WORK, IF ANY.
1. ALL LOADS AND LOADING CONDITIONS ARE PER IRC 2015 (9TH EDITION OF MASSACHUSETTS BUILDING CODE).
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS.
3. CONCRETE SHALL BE FC=3000 PSI, MIN. 5-7% AIR ENTRAINED.
4. FOUNDATION DESIGNED BASED ON ASSUMED ALLOWABLE SOIL BEARING PRESSURE OF 2000 PSF.
5. ALL EXTERIOR FOUNDATIONS SHALL BE A MIN. 4'-0" BELOW FINISHED GRADE.
6. NO FOUNDATIONS OF SLAB SHALL BE PLACED IN WATER OR FROZEN GROUND.
7. BASEMENT FOUNDATION WALLS ARE NOT DESIGNED TO BE FREE STANDING. PROVIDE ADEQUATE BRACING PRIOR TO BACKFILL; OR
BACKFILL AFTER FIRST FLOOR FRAMING HAS BEEN INSTALLED.
8. ALL REBAR SHALL BE FY=60 KSI.
9. ALL EXTERIOR WALLS SHALL BE 2X6 @ 16" O.C.
10. ALL MEMBERS DESIGNATED AS 1.75"X_" SHALL BE LVL BEAMS.
11. ALL MEMBERS DESIGNATED AS 2X_ SHALL BE DIMENSIONAL LUMBER.
12. ALL DIMENSIONAL LUMBER SHALL BE SPRUCE-PINE-FIR:
12.1 FB=875 PSI
12.2 FV=135 PSI
12.3 FCPAR=425 PSI
12.4 NO.1/NO.2 OR BETTER
13. LVL PLIES SHALL BE FB=3100 PSI, PSL'S SHALL BE FB=2650 PSI, MIN.
14. ALL HEADER SIZES SHALL BE IN ACCORDANCE WITH TABLES 602.7(1), 602.7(2) AND 602.7(3) OF 2015 IRC, U.N.O.
15. NUMBER OF JACK STUDS SHALL BE IN ACCORDANCE WITH TABLES 602.7(1) AND 602.7(2) OF 2015 IRC, U.N.O.
16. EXTERIOR WALLS SHALL BE SHEATHED W/7/16" PLYWOOD OR OSB, U.N.O.
17. ALL FLOORS AND ROOFS SHALL BE SHEATHED W23/32" PLYWOOD OR OSB, U.N.O. ALL LVL HEADERS SHALL BE SUPPORTED BY 4X6 PSL
POSTS, U.N.O.
18. ALL LVL GIRDERS AND HEADERS SHALL BE SUPPORTED BY 4X6 PSL POSTS, U.N.O.
19. APPLY (2) 2X JOISTS UNDER NEW PARTITION WALLS WHICH ARE PARALLEL TO FRAMING.
20. PROVIDE BLOCKING UNDER PARTITION WALLS WHICH ARE PERPENDICULAR TO DIRECTION OF FRAMING.
STRUCTURAL NOTES:
1/2" = 1'-0"S1.0
4 ISOLATED FOOTING PAD DETAIL
1/2" = 1'-0"S1.0
3 BIG FOOT DETAIL
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
As indicated
S1.0
STRUCTURAL
PLANS
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
No. Description Date
1/4" = 1'-0"S1.0
1 PROPOSED BASEMENT STRUCTURAL PLAN
1/4" = 1'-0"S1.0
2 PROPOSED FIRST FLOOR FRAMING PLAN
24
'
-
3
1
/
2
"
9'-10"
6'
-
7
1
/
2
"
2'
-
4
1
/
2
"
9'
-
0
"
5'
-
0
"
3'
-
6
"
10
'
-
0
"
8'
-
1
0
1
/
4
"
(E
X
I
S
T
I
N
G
O
V
E
R
A
L
L
)
35
'
-
7
"
(EXISTING OVERALL)
23'-8 1/2"
JO
I
S
T
S
P
A
N
10
'
-
1
1
"
24
'
-
8
"
2'
-
6
3
/
4
"
(EXISTING OVERALL)
17'-2"
8'-6 1/4"
4'
-
0
"
10'-6"4'-0"
5'
-
7
"
REMOVE EXISTING
ROOF FRAMING
NEW 2X10 FLOOR
JOISTS W/ JOIST
HANGERS @ 16" O.C.
EXISTING FRAMING ABOVE
TO REMAIN
REPAIR OR SISTER ANY
BROKEN JOISTS
PROVIDE NEW JOIST
HANGERS AT EACH END
NEW 2X10 ROOF
RAFTERS @ 16" O.C.
W/ HURRICANE TIES
7'-0"
SE
E
E
L
E
V
A
T
I
O
N
S
F
O
R
R
A
F
T
E
R
L
E
N
G
T
H
12
'
-
6
"
25'-4 1/2"
NEW 2X10 ROOF
RAFTERS @ 16" O.C.
W/ HURRICANE TIES
EXISTING ROOF
REFRAME AS
NEEDED WITH NEW
2X10 ROOF RAFTERS
@ 16" O.C. W/
HURRICANE TIES
DORMER FRAMING
NEW 2X10 ROOF
RAFTERS @ 16" O.C.
W/ HURRICANE TIES
SEE ELEVATIONS FOR RAFTER LENGTH
9'-2 1/2"
RE
I
N
F
O
R
C
E
E
X
I
S
T
I
N
G
R
I
D
G
E
-
VE
R
I
F
Y
C
O
N
D
I
T
I
O
N
DU
R
I
N
G
D
E
M
O
C
O
N
T
A
C
T
S
L
H
G
F
O
R
S
I
Z
I
N
G
Sheet No.
Drawing Name
Scale:
Date:
Drawn By:
1/4" = 1'-0"
S1.1
STRUCTURAL
PLANS
SLHG
04/14/25
SI
N
G
L
E
-F
A
M
I
L
Y
R
E
N
O
V
A
T
I
O
N
7-
1
/
2
L
Y
M
E
S
T
R
E
E
T
SA
L
E
M
,
M
A
0
1
9
7
0
No. Description Date
1/4" = 1'-0"S1.1
1 PROPOSED SECOND FLOOR FRAMING PLAN
1/4" = 1'-0"S1.1
2 PROPOSED ROOF FRAMING PLAN