SOIL ANALYTICAL REPORT (3)L2539761
CarriageHouse Consulting Inc.
MA230202
ALP FRAMINGHAM
Client:
Project Name:
Project Number:
06/26/25
Eight Walkup Drive, Westborough, MA 01581-1019
Lab Number:
Report Date:
508-898-9220 (Fax) 508-898-9193 800-624-9220 - www.alphalab.com
8A Pleasant Street South
Natick, MA 01760
Brian MooreATTN:
ANALYTICAL REPORT
(508) 315-3146Phone:
The original project report/data package is held by Pace Analytical Services. This report/data package is paginated and should be reproduced only
in its entirety. Pace Analytical Services holds no responsibility for results and/or data that are not consistent with the original.
Certifications & Approvals: MA (M-MA086), NH NELAP (2064), CT (PH-0826), IL (200077), IN (C-MA-03), KY (KY98045), ME (MA00086), MD (348),
NJ (MA935), NY (11148), NC (25700/666), OR (MA-1316), PA (68-03671), RI (LAO00065), TX (T104704476), VT (VT-0935), VA (460195), USDA
(Permit #525-23-122-91930A1).
Serial_No:06262520:15
Page 1 of 30
L2539761-01
Lab
Sample ID
SC-7
Client ID
FRAMINGHAM, MA
Sample
Location
ALP FRAMINGHAM
MA230202
Project Name:
Project Number:
Lab Number:
Report Date:
L2539761
06/26/25
06/24/25 14:45
Collection
Date/TimeMatrix Receive Date
SOIL 06/24/25
Serial_No:06262520:15
Page 2 of 30
Project Name:
Project Number:
Lab Number:
Report Date:
Were all samples received in a condition consistent with those described on the Chain-of-
Custody, properly preserved (including temperature) in the field or laboratory, and
prepared/analyzed within method holding times?
Were the analytical method(s) and all associated QC requirements specified in the selected
CAM protocol(s) followed?
Were all required corrective actions and analytical response actions specified in the selected
CAM protocol(s) implemented for all identified performance standard non-conformances?
Does the laboratory report comply with all the reporting requirements specified in CAM VII A,
"Quality Assurance and Quality Control Guidelines for the Acquisition and Reporting of Analytical
Data?"
VPH, EPH, and APH Methods only: Was each method conducted without significant
modification(s)? (Refer to the individual method(s) for a list of significant modifications).
APH and TO-15 Methods only: Was the complete analyte list reported for each method?
Were all applicable CAM protocol QC and performance standard non-conformances identified
and evaluated in a laboratory narrative (including all "No" responses to Questions A through E)?
YES
YES
YES
YES
YES
N/A
YES
A
B
C
D
E a.
E b.
F
MADEP MCP Response Action Analytical Report Certification
L2539761ALP FRAMINGHAM
MA230202
Were the reporting limits at or below all CAM reporting limits specified in the selected CAM
protocol(s)?
Were all QC performance standards specified in the CAM protocol(s) achieved?
Were results reported for the complete analyte list specified in the selected CAM protocol(s)?
YES
NO
YES
G
H
I
A response to questions G, H and I is required for "Presumptive Certainty" status
This form provides certifications for all samples performed by MCP methods. Please refer to
the Sample Results and Container Information sections of this report for specification of
MCP methods used for each analysis. The following questions pertain only to MCP
Analytical Methods.
An affirmative response to questions A through F is required for "Presumptive Certainty" status
For any questions answered "No", please refer to the case narrative section on the following page(s).
06/26/25
Please note that sample matrix information is located in the Sample Results section of this report.
Serial_No:06262520:15
Page 3 of 30
ALP FRAMINGHAM
MA230202
Project Name:
Project Number:
Lab Number:
Report Date:
L2539761
06/26/25
Case Narrative
The samples were received in accordance with the Chain of Custody and no significant deviations were encountered during the preparation
or analysis unless otherwise noted. Sample Receipt, Container Information, and the Chain of Custody are located at the back of the report.
Results contained within this report relate only to the samples submitted under this Pace Lab Number and meet NELAP requirements for all
NELAP accredited parameters unless otherwise noted in the following narrative. The data presented in this report is organized by parameter
(i.e. VOC, SVOC, etc.). Sample specific Quality Control data (i.e. Surrogate Spike Recovery) is reported at the end of the target analyte list
for each individual sample, followed by the Laboratory Batch Quality Control at the end of each parameter. Tentatively Identified
Compounds (TICs), if requested, are reported for compounds identified to be present and are not part of the method/program Target
Compound List, even if only a subset of the TCL are being reported. If a sample was re-analyzed or re-extracted due to a required quality
control corrective action and if both sets of data are reported, the Laboratory ID of the re-analysis or re-extraction is designated with an "R"
or "RE", respectively.
When multiple Batch Quality Control elements are reported (e.g. more than one LCS), the associated samples for each element are noted in
the grey shaded header line of each data table. Any Laboratory Batch, Sample Specific % recovery or RPD value that is outside the listed
Acceptance Criteria is bolded in the report. In reference to questions H (CAM) or 4 (RCP) when "NO" is checked, the performance criteria
for CAM and RCP methods allow for some quality control failures to occur and still be within method compliance. In these instances, the
specific failure is not narrated but noted in the associated QC Outlier Summary Report, located directly after the Case Narrative. QC
information is also incorporated in the Data Usability Assessment table (Format 11) of our Data Merger tool, where it can be reviewed in
conjunction with the sample result, associated regulatory criteria and any associated data usability implications.
Soil/sediments and solids are reported on a dry weight basis unless otherwise noted. Tissues are reported "as received" or on a wet weight
basis, unless otherwise noted. Definitions of all data qualifiers and acronyms used in this report are provided in the Glossary located at the
back of the report.
HOLD POLICY - For samples submitted on hold, Pace's policy is to hold samples (with the exception of Air canisters) free of charge for 21
calendar days from the date the project is completed. After 21 calendar days, we will dispose of all samples submitted including those put
on hold unless you have contacted your Pace Project Manager and made arrangements for Pace to continue to hold the samples. Air
canisters will be disposed after 3 business days from the date the project is completed.
Please contact Project Management at 800-624-9220 with any questions.
Serial_No:06262520:15
Page 4 of 30
Case Narrative (continued)
ALP FRAMINGHAM
MA230202
Project Name:
Project Number:
Lab Number:
Report Date:
L2539761
06/26/25
MCP Related Narratives
Sample Receipt
In reference to question H:
A Matrix Spike was not submitted for the analysis of Total Metals.
Total Metals
L2539761-01: The sample has elevated detection limits for all elements, with the exception of mercury, due to
the dilution required by the sample matrix.
I, the undersigned, attest under the pains and penalties of perjury that, to the best of my knowledge and
belief and based upon my personal inquiry of those responsible for providing the information contained
in this analytical report, such information is accurate and complete. This certificate of analysis is not
complete unless this page accompanies any and all pages of this report.
Authorized Signature:
Title: Technical Director/Representative Date: 06/26/25
Serial_No:06262520:15
Page 5 of 30
ALP FRAMINGHAM
MA230202
Project Name:
Project Number:
L2539761Lab Number:
Report Date:
QC OUTLIER SUMMARY REPORT
06/26/25
Method Client ID (Native ID)Lab ID Parameter QC Type
Recovery/RPD
(%)
QC Limits
(%)
Data Quality
Assessment
Associated
Samples
There are no QC Outliers associated with this report.
Serial_No:06262520:15
Page 6 of 30
ORGANICS
Serial_No:06262520:15
Page 7 of 30
PETROLEUM
HYDROCARBONS
Serial_No:06262520:15
Page 8 of 30
FF
C5-C8 Aliphatics
C9-C12 Aliphatics
C9-C10 Aromatics
C5-C8 Aliphatics, Adjusted
C9-C12 Aliphatics, Adjusted
Benzene
Toluene
Ethylbenzene
p/m-Xylene
o-Xylene
Methyl tert butyl ether
Naphthalene
Parameter Result Dilution Factor
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Volatile Petroleum Hydrocarbons - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
5.84
5.84
5.84
5.84
5.84
0.117
0.117
0.117
0.117
0.117
0.058
0.234
2,5-Dibromotoluene-PID
2,5-Dibromotoluene-FID
113
112
70-130
70-130
Acceptance
CriteriaSurrogate % Recovery Qualifier
Condition of sample received:
Sample Temperature upon receipt:
Were samples received in methanol?
Methanol ratio:
Satisfactory
Received on Ice
Covering the Soil
1:1 +/- 25%
Quality Control Information
06/26/25
SC-7Client ID:
06/24/25 14:45Date Collected:
06/24/25Date Received:
Matrix:Soil
FRAMINGHAM, MASample Location:
L2539761-01Lab ID:
Field Prep:
Analytical Method:
Analytical Date:
Analyst:
131,VPH-18-2.1
06/26/25 11:49
BAD
Not Specified
Percent Solids: 91%
MDL
--
--
--
--
--
--
--
--
--
--
--
--
Sample Depth:
EST, Carbopack B/Carboxen 1000&1001Trap:Restek, RTX-502.2,
105m, 0.53ID, 3um
Analytical Column:
Serial_No:06262520:15
Page 9 of 30
FF
C9-C18 Aliphatics
C19-C36 Aliphatics
C11-C22 Aromatics
C11-C22 Aromatics, Adjusted
Naphthalene
2-Methylnaphthalene
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo(a)anthracene
Chrysene
Benzo(b)fluoranthene
Benzo(k)fluoranthene
Benzo(a)pyrene
Indeno(1,2,3-cd)Pyrene
Dibenzo(a,h)anthracene
Benzo(ghi)perylene
Parameter Result Dilution Factor
ND
38.5
10.1
10.1
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Qualifier Units RL
Extractable Petroleum Hydrocarbons - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
7.11
7.11
7.11
7.11
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
0.356
Condition of sample received:
Sample Temperature upon receipt:
Sample Extraction method:
Satisfactory
Received on Ice
Extracted Per the Method
Quality Control Information
06/26/25
SC-7Client ID:
06/24/25 14:45Date Collected:
06/24/25Date Received:
Matrix:Soil
FRAMINGHAM, MASample Location:
L2539761-01Lab ID:
Field Prep:
Extraction Method:
Cleanup Method1:
Analytical Method:
Analytical Date:
Analyst:
135,EPH-19-2.1
06/26/25 10:07
CRE
Not Specified
EPA 3546
EPH-19-2.1
Extraction Date:06/25/25 05:53
Cleanup Date1:06/25/25
Percent Solids: 91%
MDL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Sample Depth:
Serial_No:06262520:15
Page 10 of 30
Parameter Result Dilution FactorQualifierUnitsRL
Extractable Petroleum Hydrocarbons - Westborough Lab
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
Chloro-Octadecane
o-Terphenyl
2-Fluorobiphenyl
2-Bromonaphthalene
62
77
81
83
40-140
40-140
40-140
40-140
Acceptance
CriteriaSurrogate % Recovery Qualifier
06/26/25
SC-7Client ID:
06/24/25 14:45Date Collected:
06/24/25Date Received:
FRAMINGHAM, MASample Location:
L2539761-01Lab ID:
Field Prep:Not Specified
MDL
Sample Depth:
Serial_No:06262520:15
Page 11 of 30
Method Blank Analysis
Batch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
06/25/25 10:33
135,EPH-19-2.1Analytical Method:
Analytical Date:
Extraction Method:
Cleanup Method:
EPA 3546
EPH-19-2.1
Extraction Date:06/24/25 11:14
06/26/25
Analyst:SYR
C9-C18 Aliphatics
C19-C36 Aliphatics
C11-C22 Aromatics
C11-C22 Aromatics, Adjusted
Naphthalene
2-Methylnaphthalene
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo(a)anthracene
Chrysene
Benzo(b)fluoranthene
Benzo(k)fluoranthene
Benzo(a)pyrene
Indeno(1,2,3-cd)Pyrene
Dibenzo(a,h)anthracene
Benzo(ghi)perylene
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
6.36
6.36
6.36
6.36
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
0.318
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
UnitsQualifier
Extractable Petroleum Hydrocarbons - Westborough Lab for sample(s): 01 Batch: WG2082746-1
Chloro-Octadecane
o-Terphenyl
2-Fluorobiphenyl
2-Bromonaphthalene
49
70
80
82
40-140
40-140
40-140
40-140
Surrogate %Recovery Qualifier
Acceptance
Criteria
Cleanup Date:06/24/25
MDL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Serial_No:06262520:15
Page 12 of 30
Method Blank Analysis
Batch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
06/26/25 11:19
131,VPH-18-2.1Analytical Method:
Analytical Date:
06/26/25
Analyst:BAD
C5-C8 Aliphatics
C9-C12 Aliphatics
C9-C10 Aromatics
C5-C8 Aliphatics, Adjusted
C9-C12 Aliphatics, Adjusted
Benzene
Toluene
Ethylbenzene
p/m-Xylene
o-Xylene
Methyl tert butyl ether
Naphthalene
Parameter Result
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
RL
5.00
5.00
5.00
5.00
5.00
0.100
0.100
0.100
0.100
0.100
0.050
0.200
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
UnitsQualifier
Volatile Petroleum Hydrocarbons - Westborough Lab for sample(s): 01 Batch: WG2083905-4
2,5-Dibromotoluene-PID
2,5-Dibromotoluene-FID
93
93
70-130
70-130
Surrogate %Recovery Qualifier
Acceptance
Criteria
MDL
--
--
--
--
--
--
--
--
--
--
--
--
Serial_No:06262520:15
Page 13 of 30
C9-C18 Aliphatics
C19-C36 Aliphatics
C11-C22 Aromatics
Naphthalene
2-Methylnaphthalene
Acenaphthylene
Acenaphthene
Fluorene
Phenanthrene
Anthracene
Fluoranthene
Pyrene
Benzo(a)anthracene
Chrysene
Benzo(b)fluoranthene
Benzo(k)fluoranthene
Benzo(a)pyrene
Indeno(1,2,3-cd)Pyrene
Dibenzo(a,h)anthracene
Benzo(ghi)perylene
56
60
71
65
65
64
67
69
67
81
67
68
69
69
64
64
76
62
63
58
54
60
64
58
61
60
63
64
62
76
61
62
63
62
58
58
69
56
57
53
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
40-140
4
0
10
11
6
6
6
8
8
6
9
9
9
11
10
10
10
10
10
9
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
Parameter
LCS
%Recovery
LCSD
%Recovery
%Recovery
Limits RPD
RPD
Limits
Extractable Petroleum Hydrocarbons - Westborough Lab Associated sample(s): 01 Batch: WG2082746-2 WG2082746-3
Lab Control Sample Analysis
Batch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
06/26/25
Qual Qual Qual
Serial_No:06262520:15
Page 14 of 30
Parameter
LCS
%Recovery
LCSD
%Recovery
%Recovery
Limits RPD
RPD
Limits
Extractable Petroleum Hydrocarbons - Westborough Lab Associated sample(s): 01 Batch: WG2082746-2 WG2082746-3
Lab Control Sample Analysis
Batch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
Chloro-Octadecane
o-Terphenyl
2-Fluorobiphenyl
2-Bromonaphthalene
% Naphthalene Breakthrough
% 2-Methylnaphthalene Breakthrough
48
66
74
75
0
0
40-140
40-140
40-140
40-140
48
60
70
71
0
0
Surrogate Qual%Recovery Qual%Recovery
LCS LCSD
06/26/25
Acceptance
Criteria
Qual Qual Qual
Serial_No:06262520:15
Page 15 of 30
C5-C8 Aliphatics
C9-C12 Aliphatics
C9-C10 Aromatics
Benzene
Toluene
Ethylbenzene
p/m-Xylene
o-Xylene
Methyl tert butyl ether
Naphthalene
1,2,4-Trimethylbenzene
Pentane
2-Methylpentane
2,2,4-Trimethylpentane
n-Nonane
n-Decane
n-Butylcyclohexane
86
104
104
102
104
107
107
107
101
106
104
70
87
98
104
104
104
86
102
102
100
102
105
104
104
98
106
102
70
88
97
102
102
102
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
70-130
30-130
70-130
70-130
0
2
2
2
2
2
3
3
3
0
2
1
1
1
2
2
2
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
Parameter
LCS
%Recovery
LCSD
%Recovery
%Recovery
Limits RPD
RPD
Limits
Volatile Petroleum Hydrocarbons - Westborough Lab Associated sample(s): 01 Batch: WG2083905-2 WG2083905-3
Lab Control Sample Analysis
Batch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
2,5-Dibromotoluene-PID
2,5-Dibromotoluene-FID
105
104
70-130
70-130
104
103
Surrogate Qual%Recovery Qual%Recovery
LCS LCSD
06/26/25
Acceptance
Criteria
Qual Qual Qual
Serial_No:06262520:15
Page 16 of 30
METALS
Serial_No:06262520:15
Page 17 of 30
FF
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
06/26/25
SAMPLE RESULTS
SC-7Client ID:
06/24/25 14:45Date Collected:
06/24/25Date Received:
Matrix:Soil
FRAMINGHAM, MASample Location:
L2539761-01Lab ID:
Field Prep:Not Specified
Parameter Result
Dilution
FactorQualifierUnitsRL
Date
Analyzed
Analytical
Method Analyst
Date
Prepared
MCP Total Metals - Mansfield Lab
Antimony, Total
Arsenic, Total
Barium, Total
Beryllium, Total
Cadmium, Total
Chromium, Total
Lead, Total
Mercury, Total
Nickel, Total
Selenium, Total
Silver, Total
Thallium, Total
Vanadium, Total
Zinc, Total
ND
3.40
45.7
ND
ND
12.2
56.1
ND
11.0
ND
ND
ND
17.1
37.6
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
2
2
2
2
2
2
2
1
2
2
2
2
2
2
4.35
0.870
0.870
0.435
0.870
0.870
4.35
0.069
2.18
4.35
0.870
4.35
0.870
4.35
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 15:58
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
06/26/25 16:10
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,7471B
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
DHL
DHL
DHL
DHL
DHL
DHL
DHL
CME
DHL
DHL
DHL
DHL
DHL
DHL
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 12:25
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
EPA 3050B
EPA 3050B
EPA 3050B
EPA 3050B
EPA 3050B
EPA 3050B
EPA 3050B
EPA 7471B
EPA 3050B
EPA 3050B
EPA 3050B
EPA 3050B
EPA 3050B
EPA 3050B
Prep
Method
Percent Solids: 91%
MDL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Sample Depth:
Serial_No:06262520:15
Page 18 of 30
FF
Parameter
Parameter
Result
Result
Dilution
Factor
Dilution
Factor
Qualifier
Qualifier
Units
Units
RL
RL
Method Blank Analysis
Batch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
Date
Analyzed
Date
Analyzed
Analytical
Method
Analytical
Method
Analyst
Analyst
Date
Prepared
Date
Prepared
06/26/25
Antimony, Total
Arsenic, Total
Barium, Total
Beryllium, Total
Cadmium, Total
Chromium, Total
Lead, Total
Nickel, Total
Selenium, Total
Silver, Total
Thallium, Total
Vanadium, Total
Zinc, Total
Mercury, Total
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
ND
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
mg/kg
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2.00
0.400
0.400
0.200
0.400
0.400
2.00
1.00
2.00
0.400
2.00
0.400
2.00
0.083
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 13:33
06/26/25 15:11
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,6010D
97,7471B
DHL
DHL
DHL
DHL
DHL
DHL
DHL
DHL
DHL
DHL
DHL
DHL
DHL
CME
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 10:53
06/26/25 12:25
MCP Total Metals - Mansfield Lab for sample(s): 01 Batch: WG2083591-1
MCP Total Metals - Mansfield Lab for sample(s): 01 Batch: WG2083592-1
EPA 3050B
EPA 7471B
Digestion Method:
Digestion Method:
Prep Information
Prep Information
MDL
MDL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Serial_No:06262520:15
Page 19 of 30
Antimony, Total
Arsenic, Total
Barium, Total
Beryllium, Total
Cadmium, Total
Chromium, Total
Lead, Total
Nickel, Total
Selenium, Total
Silver, Total
Thallium, Total
Vanadium, Total
Zinc, Total
Mercury, Total
104
103
112
110
118
114
116
119
118
117
118
113
114
108
98
97
106
110
103
106
108
110
112
109
104
106
106
113
5-195
81-119
82-118
82-118
82-118
81-119
82-118
82-119
78-121
79-121
80-120
79-122
80-120
70-130
6
6
6
0
14
7
7
8
5
7
13
6
7
5
30
30
30
30
30
30
30
30
30
30
30
30
30
30
Parameter
LCS
%Recovery
LCSD
%Recovery
%Recovery
Limits RPD RPD Limits
MCP Total Metals - Mansfield Lab Associated sample(s): 01 Batch: WG2083591-2 WG2083591-3 SRM Lot Number: D126-540
MCP Total Metals - Mansfield Lab Associated sample(s): 01 Batch: WG2083592-2 WG2083592-3 SRM Lot Number: D126-540
Lab Control Sample Analysis
Batch Quality Control
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
06/26/25
Qual Qual Qual
Serial_No:06262520:15
Page 20 of 30
INORGANICS
&
MISCELLANEOUS
Serial_No:06262520:15
Page 21 of 30
FF
SC-7Client ID:
06/24/25 14:45Date Collected:
06/24/25Date Received:
Parameter Result
Dilution
Factor
Matrix:Soil
FRAMINGHAM, MASample Location:
L2539761-01Lab ID:
Qualifier Units RL
SAMPLE RESULTS
Project Name:
Project Number:
Lab Number:
Report Date:
ALP FRAMINGHAM
MA230202
L2539761
Field Prep:
Date
Analyzed
Analytical
Method Analyst
Not Specified
General Chemistry - Westborough Lab
Solids, Total 91.0 %10.100 06/25/25 04:02 121,2540G JMN
Date
Prepared
-
06/26/25
MDL
NA
Sample Depth:
Serial_No:06262520:15
Page 22 of 30
*Values in parentheses indicate holding time in days
L2539761-01A
L2539761-01B
L2539761-01C
L2539761-01D
L2539761-01E
L2539761-01F
L2539761-01G
Vial MeOH preserved
Vial water preserved
Vial water preserved
Plastic 2oz unpreserved for TS
Metals Only-Glass 60mL/2oz unpreserved
Glass 250ml/8oz unpreserved
Glass 500ml/16oz unpreserved
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Y
Y
Y
Y
Y
Y
Y
Absent
Absent
Absent
Absent
Absent
Absent
Absent
A Absent
Cooler Custody Seal
Cooler Information
ALP FRAMINGHAM
MA230202
HOLD-8260HLW(14),VPH-DELUX-18(28)
HOLD-8260HLW(14)
HOLD-8260HLW(14)
TS(7)
MCP-CR-6010T-10(180),MCP-AS-6010T-
10(180),MCP-TL-6010T-10(180),MCP-
7471T-10(28),MCP-CD-6010T-
10(180),MCP-ZN-6010T-10(180),MCP-SB-
6010T-10(180),MCP-AG-6010T-
10(180),MCP-BE-6010T-10(180),MCP-SE-
6010T-10(180),MCP-V-6010T-
10(180),MCP-BA-6010T-10(180),MCP-NI-
6010T-10(180),MCP-PB-6010T-10(180)
HOLD-WETCHEM()
EPH-DELUX-20(14),HOLD-
8270(14),HOLD-8082(14)
Project Name:
Project Number:
L2539761Lab Number:
Report Date:
Sample Receipt and Container Information
Container ID Container Type Cooler
Temp
deg C Pres Seal
Container Information
Analysis(*)
06/26/25
Were project specific reporting limits specified?YES
24-JUN-25 19:26
24-JUN-25 19:26
Frozen
Date/Time
Final
pH
Initial
pH
Serial_No:06262520:15
Page 23 of 30
Report Format:Data Usability Report
GLOSSARY
Project Name:
Project Number:
Lab Number:
Report Date:
L2539761ALP FRAMINGHAM
MA230202 06/26/25
Acronyms
DL
EDL
EMPC
EPA
LCS
LCSD
LFB
LOD
LOQ
MDL
MS
MSD
NA
NC
NDPA/DPA
NI
NP
NR
RL
RPD
SRM
STLP
TEF
TEQ
TIC
Detection Limit: This value represents the level to which target analyte concentrations are reported as estimated values, when
those target analyte concentrations are quantified below the limit of quantitation (LOQ). The DL includes any adjustments
from dilutions, concentrations or moisture content, where applicable. (DoD report formats only.)
Estimated Detection Limit: This value represents the level to which target analyte concentrations are reported as estimated
values, when those target analyte concentrations are quantified below the reporting limit (RL). The EDL includes any
adjustments from dilutions, concentrations or moisture content, where applicable. The use of EDLs is specific to the analysis
of PAHs using Solid-Phase Microextraction (SPME).
Estimated Maximum Possible Concentration: The concentration that results from the signal present at the retention time of an
analyte when the ions meet all of the identification criteria except the ion abundance ratio criteria. An EMPC is a worst-case
estimate of the concentration.
Environmental Protection Agency.
Laboratory Control Sample: A sample matrix, free from the analytes of interest, spiked with verified known amounts of
analytes or a material containing known and verified amounts of analytes.
Laboratory Control Sample Duplicate: Refer to LCS.
Laboratory Fortified Blank: A sample matrix, free from the analytes of interest, spiked with verified known amounts of
analytes or a material containing known and verified amounts of analytes.
Limit of Detection: This value represents the level to which a target analyte can reliably be detected for a specific analyte in a
specific matrix by a specific method. The LOD includes any adjustments from dilutions, concentrations or moisture content,
where applicable. (DoD report formats only.)
Limit of Quantitation: The value at which an instrument can accurately measure an analyte at a specific concentration. The
LOQ includes any adjustments from dilutions, concentrations or moisture content, where applicable. (DoD report formats
only.)
Limit of Quantitation: The value at which an instrument can accurately measure an analyte at a specific concentration. The
LOQ includes any adjustments from dilutions, concentrations or moisture content, where applicable. (DoD report formats
only.)
Method Detection Limit: This value represents the level to which target analyte concentrations are reported as estimated
values, when those target analyte concentrations are quantified below the reporting limit (RL). The MDL includes any
adjustments from dilutions, concentrations or moisture content, where applicable.
Matrix Spike Sample: A sample prepared by adding a known mass of target analyte to a specified amount of matrix sample for
which an independent estimate of target analyte concentration is available. For Method 332.0, the spike recovery is calculated
using the native concentration, including estimated values.
Matrix Spike Sample Duplicate: Refer to MS.
Not Applicable.
Not Calculated: Term is utilized when one or more of the results utilized in the calculation are non-detect at the parameter's
reporting unit.
N-Nitrosodiphenylamine/Diphenylamine.
Not Ignitable.
Non-Plastic: Term is utilized for the analysis of Atterberg Limits in soil.
No Results: Term is utilized when 'No Target Compounds Requested' is reported for the analysis of Volatile or Semivolatile
Organic TIC only requests.
Reporting Limit: The value at which an instrument can accurately measure an analyte at a specific concentration. The RL
includes any adjustments from dilutions, concentrations or moisture content, where applicable.
Relative Percent Difference: The results from matrix and/or matrix spike duplicates are primarily designed to assess the
precision of analytical results in a given matrix and are expressed as relative percent difference (RPD). Values which are less
than five times the reporting limit for any individual parameter are evaluated by utilizing the absolute difference between the
values; although the RPD value will be provided in the report.
Standard Reference Material: A reference sample of a known or certified value that is of the same or similar matrix as the
associated field samples.
Semi-dynamic Tank Leaching Procedure per EPA Method 1315.
Toxic Equivalency Factors: The values assigned to each dioxin and furan to evaluate their toxicity relative to 2,3,7,8-TCDD.
Toxic Equivalent: The measure of a sample's toxicity derived by multiplying each dioxin and furan by its corresponding TEF
and then summing the resulting values.
Tentatively Identified Compound: A compound that has been identified to be present and is not part of the target compound
list (TCL) for the method and/or program. All TICs are qualitatively identified and reported as estimated concentrations.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Serial_No:06262520:15
Page 24 of 30
Report Format:Data Usability Report
Project Name:
Project Number:
Lab Number:
Report Date:
L2539761ALP FRAMINGHAM
MA230202 06/26/25
Terms
Analytical Method: Both the document from which the method originates and the analytical reference method. (Example: EPA 8260B is
shown as 1,8260B.) The codes for the reference method documents are provided in the References section of the Addendum.
Chlordane: The target compound Chlordane (CAS No. 57-74-9) is reported for GC ECD analyses. Per EPA,this compound "refers to a
mixture of chlordane isomers, other chlorinated hydrocarbons and numerous other components." (Reference: USEPA Toxicological Review
of Chlordane, In Support of Summary Information on the Integrated Risk Information System (IRIS), December 1997.)
Difference: With respect to Total Oxidizable Precursor (TOP) Assay analysis, the difference is defined as the Post-Treatment value minus the
Pre-Treatment value.
Final pH: As it pertains to Sample Receipt & Container Information section of the report, Final pH reflects pH of container determined after
adjustment at the laboratory, if applicable. If no adjustment required, value reflects Initial pH.
Frozen Date/Time: With respect to Volatile Organics in soil, Frozen Date/Time reflects the date/time at which associated Reagent Water-
preserved vials were initially frozen. Note: If frozen date/time is beyond 48 hours from sample collection, value will be reflected in 'bold'.
Gasoline Range Organics (GRO): Gasoline Range Organics (GRO) results include all chromatographic peaks eluting from Methyl tert butyl
ether through Naphthalene, with the exception of GRO analysis in support of State of Ohio programs, which includes all chromatographic
peaks eluting from Hexane through Dodecane.
Initial pH: As it pertains to Sample Receipt & Container Information section of the report, Initial pH reflects pH of container determined upon
receipt, if applicable.
PAH Total: With respect to Alkylated PAH analyses, the 'PAHs, Total' result is defined as the summation of results for all or a subset of the
following compounds: Naphthalene, C1-C4 Naphthalenes, 2-Methylnaphthalene, 1-Methylnaphthalene, Biphenyl, Acenaphthylene,
Acenaphthene, Fluorene, C1-C3 Fluorenes, Phenanthrene, C1-C4 Phenanthrenes/Anthracenes, Anthracene, Fluoranthene, Pyrene, C1-C4
Fluoranthenes/Pyrenes, Benz(a)anthracene, Chrysene, C1-C4 Chrysenes, Benzo(b)fluoranthene, Benzo(j)+(k)fluoranthene, Benzo(e)pyrene,
Benzo(a)pyrene, Perylene, Indeno(1,2,3-cd)pyrene, Dibenz(ah)+(ac)anthracene, Benzo(g,h,i)perylene. If a 'Total' result is requested, the
results of its individual components will also be reported.
PFAS Total: With respect to PFAS analyses, the 'PFAS, Total (5)' result is defined as the summation of results for: PFHpA, PFHxS, PFOA,
PFNA and PFOS. In addition, the 'PFAS, Total (6)' result is defined as the summation of results for: PFHpA, PFHxS, PFOA, PFNA, PFDA
and PFOS. For MassDEP DW compliance analysis only, the 'PFAS, Total (6)' result is defined as the summation of results at or above the
RL. Note: If a 'Total' result is requested, the results of its individual components will also be reported.
Total: With respect to Organic analyses, a 'Total' result is defined as the summation of results for individual isomers or Aroclors. If a 'Total'
result is requested, the results of its individual components will also be reported. This is applicable to 'Total' results for methods 8260, 8081
and 8082.
Data Qualifiers
A
B
C
D
E
F
G
H
I
J
M
-
-
-
-
-
-
-
-
-
-
-
Spectra identified as "Aldol Condensates" are byproducts of the extraction/concentration procedures when acetone is introduced in
the process.
The analyte was detected above the reporting limit in the associated method blank. Flag only applies to associated field samples that
have detectable concentrations of the analyte at less than ten times (10x) the concentration found in the blank. For MCP-related
projects, flag only applies to associated field samples that have detectable concentrations of the analyte at less than ten times (10x)
the concentration found in the blank. For DOD-related projects, flag only applies to associated field samples that have detectable
concentrations of the analyte at less than ten times (10x) the concentration found in the blank AND the analyte was detected above
one-half the reporting limit (or above the reporting limit for common lab contaminants) in the associated method blank. For NJ-
Air-related projects, flag only applies to associated field samples that have detectable concentrations of the analyte above the
reporting limit. For NJ-related projects (excluding Air), flag only applies to associated field samples that have detectable
concentrations of the analyte, which was detected above the reporting limit in the associated method blank or above five times the
reporting limit for common lab contaminants (Phthalates, Acetone, Methylene Chloride, 2-Butanone).
Co-elution: The target analyte co-elutes with a known lab standard (i.e. surrogate, internal standards, etc.) for co-extracted
analyses.
Concentration of analyte was quantified from diluted analysis. Flag only applies to field samples that have detectable concentrations
of the analyte.
Concentration of analyte exceeds the range of the calibration curve and/or linear range of the instrument.
The ratio of quantifier ion response to qualifier ion response falls outside of the laboratory criteria. Results are considered to be an
estimated maximum concentration.
The concentration may be biased high due to matrix interferences (i.e, co-elution) with non-target compound(s). The result should
be considered estimated.
The analysis of pH was performed beyond the regulatory-required holding time of 15 minutes from the time of sample collection.
The lower value for the two columns has been reported due to obvious interference.
Estimated value. This represents an estimated concentration for Tentatively Identified Compounds (TICs).
Reporting Limit (RL) exceeds the MCP CAM Reporting Limit for this analyte.
1 The reference for this analyte should be considered modified since this analyte is absent from the target analyte list of the
original method.
-
Footnotes
Serial_No:06262520:15
Page 25 of 30
Report Format:Data Usability Report
Project Name:
Project Number:
Lab Number:
Report Date:
L2539761ALP FRAMINGHAM
MA230202 06/26/25
Data Qualifiers
ND
NJ
P
Q
R
RE
S
V
Z
-
-
-
-
-
-
-
-
-
Not detected at the reporting limit (RL) for the sample.
Presumptive evidence of compound. This represents an estimated concentration for Tentatively Identified Compounds (TICs), where
the identification is based on a mass spectral library search.
The RPD between the results for the two columns exceeds the method-specified criteria.
The quality control sample exceeds the associated acceptance criteria. For DOD-related projects, LCS and/or Continuing Calibration
Standard exceedences are also qualified on all associated sample results. Note: This flag is not applicable for matrix spike recoveries
when the sample concentration is greater than 4x the spike added or for batch duplicate RPD when the sample concentrations are less
than 5x the RL. (Metals only.)
Analytical results are from sample re-analysis.
Analytical results are from sample re-extraction.
Analytical results are from modified screening analysis.
The surrogate associated with this target analyte has a recovery outside the QC acceptance limits. (Applicable to MassDEP DW
Compliance samples only.)
The batch matrix spike and/or duplicate associated with this target analyte has a recovery/RPD outside the QC acceptance limits.
(Applicable to MassDEP DW Compliance samples only.)
Serial_No:06262520:15
Page 26 of 30
Pace Analytical Services performs services with reasonable care and diligence normal to the analytical testing
laboratory industry. In the event of an error, the sole and exclusive responsibility of Pace Analytical Services
shall be to re-perform the work at it's own expense. In no event shall Pace Analytical Services be held liable
for any incidental, consequential or special damages, including but not limited to, damages in any way
connected with the use of, interpretation of, information or analysis provided by Pace Analytical Services.
We strongly urge our clients to comply with EPA protocol regarding sample volume, preservation, cooling,
containers, sampling procedures, holding time and splitting of samples in the field.
LIMITATION OF LIABILITIES
97
121
131
135
EPA Test Methods (SW-846) with QC Requirements & Performance Standards for the
Analysis of EPA SW-846 Methods under the Massachusetts Contingency Plan,
WSCCAM-IIA, IIB, IIIA, IIIB, IIIC, IIID, VA, VB, VC, VIA, VIB, VIIIA and VIIIB, July 2010;
WSC-CAM-IIIA and IIID, January 2024; WSC-CAM-IIIB and VA, February 2024;
WSC-CAM-VB and VC, April 2024; and WSC-CAM-VIA, VIB, IXA, and IXB, October
2024.
Standard Methods for the Examination of Water and Wastewater. APHA-AWWA-WEF.
Standard Methods Online.
Method for the Determination of Volatile Petroleum Hydrocarbons (VPH), MassDEP,
February 2018, Revision 2.1 with QC Requirements & Performance Standards for the
Analysis of VPH under the Massachusetts Contingency Plan, WSC-CAM-IVA, June 1,
2018.
Method for the Determination of Extractable Petroleum Hydrocarbons (EPH), MassDEP,
December 2019, Revision 2.1 with QC Requirements & Performance Standards for the
Analysis of EPH under the Massachusetts Contingency Plan, WSC-CAM-IVB, March 1,
2020.
Project Name:
Project Number:
Lab Number:
Report Date:
L2539761ALP FRAMINGHAM
MA230202
REFERENCES
06/26/25
Serial_No:06262520:15
Page 27 of 30
Pace Analytical Services LLC ID No.:17873
Facility: Northeast Revision 27
Department: Quality Assurance Published Date: 01/24/2025
Title: Certificate/Approval Program Summary Page 1 of 2
Document Type: Form Pre-Qualtrax Document ID: 08-113
Certification Information
The following analytes are not included in our Primary NELAP Scope of Accreditation:
Westborough Facility – 8 Walkup Dr. Westborough, MA 01581
EPA 624.1: m/p-xylene, o-xylene, Naphthalene
EPA 625.1: alpha-Terpineol
EPA 8260D: NPW: 1,2,4,5-Tetramethylbenzene; 4-Ethyltoluene;SCM:Iodomethane (methyl iodide), 1,2,4,5-Tetramethylbenzene; 4-Ethyltoluene.
EPA 8270E: NPW: Dimethylnaphthalene,1,4-Diphenylhydrazine, alpha-Terpineol, Azobenzene; SCM: Dimethylnaphthalene,1,4-Diphenylhydrazine.
SM4500: NPW: Amenable Cyanide; SCM: Total Phosphorus, TKN, NO2, NO3.
Mansfield Facility – 320 Forbes Blvd. Mansfield, MA 02048
SM 2540D: TSS.
EPA TO-15: Halothane, 2,4,4-Trimethyl-2-pentene, 2,4,4-Trimethyl-1-pentene, Thiophene, 2-Methylthiophene,
3-Methylthiophene, 2-Ethylthiophene, 1,2,3-Trimethylbenzene, Indan, Indene, 1,2,4,5-Tetramethylbenzene, Benzothiophene, 1-Methylnaphthalene.
MADEP-APH.
Nonpotable Water: EPA RSK-175 Dissolved Gases
Biological Tissue Matrix:EPA 3050B
Mansfield Facility – 120 Forbes Blvd. Mansfield, MA 02048
EPA TO-15: Halothane, 2,4,4-Trimethyl-2-pentene, 2,4,4-Trimethyl-1-pentene, Thiophene, 2-Methylthiophene,
3-Methylthiophene, 2-Ethylthiophene, 1,2,3-Trimethylbenzene, Indan, Indene, 1,2,4,5-Tetramethylbenzene, Benzothiophene, 1-Methylnaphthalene.
Nonpotable Water: EPA RSK-175 Dissolved Gases
The following test method is not included in our New Jersey Secondary NELAP Scope of Accreditation:
Mansfield Facility – 320 Forbes Blvd. Mansfield, MA 02048
Determination of Selected Perfluorinated Alkyl Substances by Solid Phase Extraction and Liquid Chromatography/Tandem Mass
Spectrometry Isotope Dilution (via Alpha SOP 23528)
The following analytes are included in our Massachusetts DEP Scope of Accreditation
Westborough Facility – 8 Walkup Dr. Westborough, MA 01581
Drinking Water
EPA 300.0: Chloride, Nitrate-N, Fluoride, Sulfate; EPA 353.2: Nitrate-N, Nitrite-N; SM4500NO3-F: Nitrate-N, Nitrite-N; SM4500F-C, SM4500CN-CE,
EPA 180.1, SM2130B, SM4500Cl-D, SM2320B, SM2540C, SM4500H-B, SM4500NO2-B
EPA 524.2: THMs and VOCs; EPA 504.1: EDB, DBCP.
Microbiology: SM9215B; SM9223-P/A, SM9223B-Colilert-QT,SM9222D.
Non-Potable Water
SM4500H,B, EPA 120.1, SM2510B, SM2540C, SM2320B, SM4500CL-E, SM4500F-BC, SM4500NH3-BH: Ammonia-N and Kjeldahl-N, EPA 350.1:
Ammonia-N, LACHAT 10-107-06-1-B: Ammonia-N, EPA 351.1,SM4500NO3-F, EPA 353.2: Nitrate-N, SM4500P-E, SM4500P-B, E, SM4500SO4-E,
SM5220D, EPA 410.4, SM5210B, SM5310C, SM4500CL-D, EPA 1664, EPA 420.1, SM4500-CN-CE, SM2540D, EPA 300: Chloride, Sulfate, Nitrate.
EPA 624.1: Volatile Halocarbons & Aromatics,
EPA 608.3: Chlordane, Toxaphene, Aldrin, alpha-BHC, beta-BHC, gamma-BHC, delta-BHC, Dieldrin, DDD, DDE, DDT, Endosulfan I, Endosulfan II,
Endosulfan sulfate, Endrin, Endrin Aldehyde, Heptachlor, Heptachlor Epoxide, PCBs
EPA 625.1: SVOC (Acid/Base/Neutral Extractables).
Microbiology: SM9223B-Colilert-QT; Enterolert-QT, EPA 1600, EPA 1603, SM9222D.
Mansfield Facility – 320 Forbes Blvd. Mansfield, MA 02048
Drinking Water
EPA 200.7: Al, Ba, Cd, Cr, Cu, Fe, Mn, Ni, Na, Ag, Ca, Zn. EPA 200.8: Al,Sb, As, Ba, Be, Cd, Cr, Cu, Pb, Mn, Ni, Se, Ag, TL, Zn. EPA 245.1 Hg.
EPA 522, EPA 537.1.
Non-Potable Water
EPA 200.7: Al, Sb, As, Be, Cd, Ca, Cr, Co, Cu, Fe, Pb, Mg, Mn, Mo, Ni, K, Se, Ag, Na, Sr, TL, Ti, V, Zn.
EPA 200.8: Al,Sb, As, Be, Cd, Cr, Cu, Fe, Pb, Mn, Ni, K, Se, Ag, Na, TL, Zn.
EPA 245.1 Hg.
SM2340B
Serial_No:06262520:15
Page 28 of 30
Pace Analytical Services LLC ID No.:17873
Facility: Northeast Revision 27
Department: Quality Assurance Published Date: 01/24/2025
Title: Certificate/Approval Program Summary Page 2 of 2
Document Type: Form Pre-Qualtrax Document ID: 08-113
Certification IDs:
Westborough Facility – 8 Walkup Dr. Westborough, MA 01581
CT PH-0826, IL 200077, IN C-MA-03, KY JY98045, ME MA00086, MD 348, MA M-MA086, NH 2064, NJ MA935, NY 11148, NC (DW) 25700, NC
(NPW/SCM) 666, OR MA-1316, PA 68-03671, RI LAO00065, TX T104704476, VT VT-0935, VA 460195
Mansfield Facility – 320 Forbes Blvd. Mansfield, MA 02048
CT PH-0825, ANAB/DoD L2474, IL 200081, IN C-MA-04, KY KY98046, LA 3090, ME MA00030, MI 9110, MN 025-999-495, NH 2062, NJ MA015, NY
11627, NC (NPW/SCM) 685, OR MA-0262, PA 68-02089, RI LAO00299, TX T-104704419, VT VT-0015, VA 460194, WA C954
Mansfield Facility – 120 Forbes Blvd. Mansfield, MA 02048
ANAB/DoD L2474, ME MA01156, MN 025-999-498, NH 2249, NJ MA025, NY 12191, OR 4203, TX T104704583, VA 460311, WA C1104.
For a complete listing of analytes and methods, please contact your Project Manager.
Serial_No:06262520:15
Page 29 of 30
Serial_No:06262520:15
Page 30 of 30