48 PRINCE STREET UNIT 1 COMPLIANCE LETTER 5-19-2025 �. r CITY OF SALEM, MASSACHUSETTS lu BOARD OF HEALTH 98 WASHINGTON STREET 3R'FLOOR Pub&Health p Prevent.Promote.Protect. TEL. (978) 741-1800 DOMINICK PANGALLO health a salem.com DAVID GREENBAUM,RS MAYOR HEALTH AGENT May 19, 2025 James M. Desrocher 15 Liberty Street Middleton, MA 01949 Dear Sir: In accordance with Chapter II of the State Sanitary Code, 105 CMR 410.000, Minimum Standards of Fitness for Human Habitation, a re-inspection of your property located at 48 Prince Street Unit 1 was conducted by Jeffrey Barosy, Sanitarian of the Salem Board of Health on April 29, 2025. All violations noted in the inspection report of March 10, 2025 have been corrected. Thank you for your cooperation in this matter For the Ward of Health, Reply to: Yvd'iGreen6aurn r Baro Health Agent anitarian R-14 x City of Salem 3 Health Department Inspection Report SSC 105 CMR 410.000: Chapter II, Minimum Standards of Fitness for Human Habitation Case#: CBB04 Inspection Date: 4/29/2025 Case Status: OPEN Inspection Time: 9:28 AM Inspected by: Jeff Barosy Inspection ID: 84007 Complaint Date: 03/06/2025 Inspection Type: Re-Inspection - Physical Complainant: Occupant Comprehensive Insp?: No 1� - - _ . •'~ _ y I■ r Leaking ceiling and other issues. Dwelling Information Complaint Address: 48 Prince Street Unit 1 Salem MA 01970 Sleeping Rooms: Year Built: Sanitary Drainage: # of Children<6: Water Source: Currently Occupied: Who Pays Water: #of Occupants: Submetering Form on File: Floors: Hot Water Fuel: Stories: Heating Type: Dwelling Units: Who Pays Heat: Room Units: Owners resides on Site: Habitable Rooms: Owner lives in which Unit: Owner Information Occupant Information Other James M. Desrocher Matthew Ferrara , 15 Liberty Street 48 Prince Street Middleton, MA 01949 Unit 1 Salem, MA 01970 R-14 x INSPECTION REPORT 2 Inspection Date: 4/29/2025 48 Prince Street Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 Basement 410.200(A)(1): Provision and Metering of Electricity or Gas / 30 day(s) to correct Responsible Party: Owner Corrected: 5/19/2025 Observations:The electrical panel for unit 1 is linked to basement lights.The basement is not under the exclusive use of the occupants of unit 1. There is no written Y 1 agreement between the property owner and the occupant to pay to power the basement lights. Repair the electrical panel so it linked only to the electrical facilities under the exclusive use of the occupants of unit 1. Code Description: (A)The owner shall provide the electricity or gas used in each dwelling unit unless: (1)Such electricity or gas is metered through a meter which serves only the dwelling unit or other area under the exclusive use of an occupant of that dwelling unit, except as allowed by 105 CMR 410.300(F) No Violations Noted / day(s) to correct Responsible Party: Corrected: Observations:According to the occupant, the main sewage drain was leaking. The inspector did not observe any sewage leakage or sewage odor at the time of inspection.The inspector advises the property owner to investigate this claim. i. Code Description: No Violations Noted R-14 x INSPECTION REPORT 3 48 Prince Street Inspection Date: 4/29/2025 Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 Bathroom 1 410.500(A)(1): CDE Owner's Responsibility to Maintain Building and Structural Elements / Responsible Party: Owner Corrected: 4/29/2025 Observations:In the bathroom there is evidence of water leakage with brown staining and bowing in the ceiling tiles above the toilet. Find the cause of the water leak and v repair. Replace the damaged ceiling tiles. Code Description: (A)Every owner of a residence shall maintain all buildings and structural elements in compliance with accepted standards so they are in good repair and in every way fit for the intended use, including: (1)Protected from wind, rain and snow, and are watertight, free from excess moisture or the appearance of mold, and pest resistant No Violations Noted / day(s) to correct Responsible Party: Corrected: Observations:According to the occupant, the bathroom window is drafty. The inspector could not observe this at the time of inspection. The inspector advises the owner to investigate this claim and repair any issues that may cause the window's draftiness if found. Code Description: No Violations Noted R-14 x INSPECTION REPORT 4 48 Prince Street Inspection Date: 4/29/2025 Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 410.235(A)(1): Owner's Installation, Maintenance and Repair Responsibilities / 30 day(s) to correct Responsible Party: Owner Corrected: 4/29/2025 Observations:The bathroom sink's faucet's cold water does not turn off, having a constant drip. Repair this sink's faucet so its cold water closes off as designed and no - longer drips. Code Description: The owner shall ensure proper installation, in compliance with accepted standards and shall maintain in operable condition free from leaks, obstructions or other defects, all facilities and equipment which the owner is required to provide, and all owner installed equipment: (A)The facilities and equipment the owner is required to provide include, but are not limited to: (1)Sinks R-14 x INSPECTION REPORT 5 48 Prince Street Inspection Date: 4/29/2025 Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 Dwelling Unit 410. 330(A): CDE Smoke Detectors and Carbon Monoxide Alarms / Responsible Party: Owner Corrected: 4/29/2025 Observations:There are no carbon monoxide detectors within the dwelling unit. Provide carbon monoxide detectors within ten (10)feet of bedroom entrances.The City's Fire Department has been notified. Code Description: (A)The owner shall provide, install, and maintain in operable condition smoke detectors and carbon monoxide alarms in every residence that is required to be equipped with smoke detectors and carbon monoxide alarms in accordance with M.G.L. c. 148, §§ 26 C-F'/and 780 CMR: Massachusetts State Building Code, 527 CMR 1.00: Massachusetts Comprehensive Fire Safety Code, and 248 CMR 10.00: Uniform State Plumbing Code and in compliance with accepted standards as defined by 105 CMR 410.010. No Violations Noted / day(s) to correct Responsible Party: Corrected: Observations:The occupant informed the inspector there was an issue with the heating system not providing enough heat. At the time of inspection the inspector observed the thermostat was on and heat was radiating from the radiators. Air temperatures were not recorded because the inspector did not have an air probe and the temperature outside at the time of inspection was in the lower 60's making it difficult to determine heating system efficiency.. The inspector offers to return on a cooler day observer internal air temperatures. Code Description: No Violations Noted R-14 x INSPECTION REPORT 6 48 Prince Street Inspection Date: 4/29/2025 Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 Exterior 410.500(A)(2): CDE Owner's Responsibility to Maintain Building and Structural Elements 1 Responsible Party: Owner Corrected: 4/29/2025 Observations:The window facing Prince Street has exterior sill that is rotting. Repair this window's sill to it is intact and free of defects. 1 i Code Description: (A)Every owner of a residence shall maintain all buildings and structural elements in compliance with accepted standards so they are in good repair and in every way fit for the intended use, including: (2) Free from holes, cracks, loose plaster, or defects that renders the area difficult to keep clean, create an injury risk, or provide an entry or harborage for pests. R-14 x INSPECTION REPORT 7 48 Prince Street Inspection Date: 4/29/2025 Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 410.550(B): CDE Elimination of Pests / 1 day(s) to correct Responsible Party: Owner Corrected: 5/19/2025 Observations:A rat burrow hole was found under the porch extension facing Prince Street. Exterminate all rats on the property. Fill all burrow holes. Extermination is t continue until rats are no longer a public health nuisance on the property. Code Description: Owners and occupants are responsible for the control and elimination of pests as follows: (B)The owner of a residence containing two or more dwelling units, including a homeless shelter or a rooming house, shall maintain it and its premises free from infestation and shall be responsible for pest elimination. No Violations Noted / day(s) to correct Responsible Party: Corrected: Observations:The occupant informed the inspector there is a possible entry point for squirrels in the facade on the side of the property facing Prince Street. The inspector did not observe squirrels entering the property, but did see where holes in the facade �— had been covered with metal mesh. The inspector advises the owner to investigate for new points of entry for squirrels and close them off if found. pow f! 7 Code Description: No Violations Noted R-14 x INSPECTION REPORT 8 Inspection Date: 4/29/2025 48 Prince Street Inspection Time: 9:28 AM Unit 1 Salem, MA 01970 Inspection ID: 84007 No Violations Noted / day(s) to correct Responsible Party: Corrected: Observations:Possible rat entry under the wooden yard border facing Leavitt Street. V r Code Description: No Violations Noted No Violations Noted / day(s) to correct Responsible Party: Corrected: Observations:Possible rat entry under the stairs facing Leavitt Street. '1 Code Description: No Violations Noted R-14 x INSPECTION REPORT 9 Inspection Date: 4/29/2025 48 Prince Street Inspection Time: 9:28 AM Unit 1 Salem, MA 01970 Inspection ID: 84007 No Violations Noted / day(s) to correct Responsible Party: Corrected: Observations:The inspector advises the occupant to acquire overflow bags for garbage and rubbish that does not fit inside garbage receptacles. The inspector f advises the property owner to contact the City's Engineering department to replace damage garbage and recycling receptacles. t Code Description: No Violations Noted Hallway-Common 410. 330(A): CDE Smoke Detectors and Carbon Monoxide Alarms / 1 day(s) to correct Responsible Party: Owner Corrected: 4/29/2025 Observations:Rear common hallway lacks a smoke detector on first floor. Provide a smoke detector for this area. The City's Fire Department has been notified. Code Description: (A)The owner shall provide, install, and maintain in operable condition smoke detectors and carbon monoxide alarms in every residence that is required to be equipped with smoke detectors and carbon monoxide alarms in accordance with M.G.L. c. 148, §§26 C-F%and 780 CMR: Massachusetts State Building Code, 527 CMR 1.00: Massachusetts Comprehensive Fire Safety Code, and 248 CMR 10.00: Uniform State Plumbing Code and in compliance with accepted standards as defined by 105 CMR 410.010. R-14 x INSPECTION REPORT 10 48 Prince Street Inspection Date: 4/29/2025 Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 Kitchen 410.100(D): Kitchen Facilities / 30 day(s) to correct Responsible Party: Owner Corrected: 4/29/2025 Observations:In the kitchen, there are three tears in the vinyl/linoleum floor. Repair I the kitchen floor so there are no longer tears in the floor 4' I Code Description: (D)The floor surfaces of every kitchen and pantry shall be smooth, noncorrosive, and nonabsorbent. Wood flooring is allowed provided the flooring has a water-resistant finish and is maintained so as to prevent the accumulation of dirt and food or the harborage of pests. R-14 x INSPECTION REPORT 11 Inspection Date: 4/29/2025 48 Prince Street Unit 1 Inspection Time: 9:28 AM Salem, MA 01970 Inspection ID: 84007 Living Room 410.235(A)(12): Owner's Installation, Maintenance and Repair Responsibilities 130 day(s) to correct Responsible Party: Owner Corrected: 4/29/2025 Observations:The living room, which is being used as a bedroom, has a wall- mounted light fixture that is separating from the wall. Repair this light fixture so it is properly affixed to the wall. Code Description: The owner shall ensure proper installation, in compliance with accepted standards and shall maintain in operable condition free from leaks, obstructions or other defects, all facilities and equipment which the owner is required to provide, and all owner installed equipment: (A)The facilities and equipment the owner is required to provide include, but are not limited to: (12) Electrical light fixtures, switches, outlets and wiring R-14 x INSPECTION REPORT 12 Inspection Date: 4/29/2025 48 Prince Street Inspection Time: 9:28 AM Unit 1 Salem, MA 01970 Inspection ID: 84007 Notes AIL The inspector did not observe evidence of mice in the dwelling unit at the time of re-inspection. The occupant informed the inspector he occasionally hears mice in his ceiling. The inspector contacted the property manager, Maggie Turcotte, and informed her of what the occupant told him about hearing mice in the ceiling. The property manager acquired a pest control service with an annual contract to exterminate mice on the property and delivered documentation of the initial service to the inspector for the Salem Board of Health's records. Inspector Other This inspection report is signed and certified under the pains and penalty of perjury