56 School Street Salem MA Permit Set (1)APPLICABLE CODES: 2021 INTERNATIONAL RESIDENTIAL CODE 2021 INTERNATIONAL MECHANICAL CODE 2021 PLUMBING CODE 2021 INTERNATIONAL ENERGY CODE CITY OF SALEM ZONING ORDINANCE BUILDING CONSTRUCTION: FLOOR -WOOD FRAME EXTERIOR WALLS -WOOD SHINGLES/LAP SIDING, PVC TRIM W/ STUD BACKUP INTERIOR WALLS -WOOD STUD W/ BLUEBOARD & PLASTER FINISH BUILDING IS LOCATED ON ZONE R2-RESIDENTAIL TWO-FAMILY BUILDING INFORMATION: GENERAL NOTES: 1.CONSTRUCTION TO BE IN ACCORDANCE WITH THE XXX (STATE) BUILDING CODE, NINTH EDITION (FOR ONE & TWO FAMILY DWELLINGS) (MA)AND THE INTERNATIONAL RESIDENTIAL CODE (IRC 2021). 2.THE CONTRACTOR IS RESPONSIBLE FOR ALL LABOR, MATERIALS, MEANS, AND METHODS OF CONSTRUCTION ASSOCIATED WITH THIS PROJECT. 3.CONTRACTOR SHALL CONFIRM ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE DRAWINGS. 4.THE CONTRACTOR SHALL FAMILIARIZE THEMSELVES WITH THE CONTRACT DRAWINGS, ANY DISCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DESIGNER OR ENGINEER BEFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUBSTITUTIONS OF STRUCTURAL MATERIAL OR DETAILS FROM THOSE DEPICTED ON THE DRAWINGS MAY BE MADE ONLY WITH THE PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER. 5.SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO PURCHASE, FABRICATION, OR INSTALLATION. 6.CONTRACTOR SHALL MAINTAIN SMOKE FREE PREMISES CLEAN AND FREE OF ALL TRASH DEBRIS AND SHALL PROTECT ALL ADJACENT WORK FROM DAMAGE, SOILILNG, PAINT OVERSPRAY, ETC. ALL FIXTURES, EQUIPMENT, GLAZING, FLOORS ETC. SHALL BE LEFT CLEAN AND READY FOR OCCUPANCY UPON CMPLETIOTN OF THE PROJECT. 7.ALL MANUFACTURER'S PRINTED WARNINGS FOR HANDLING OF PRODUCTS MUST BE STRICTLY OBSERVED. SAVE ALL MATERIAL FOR OWNER. 8.THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOB SAFETY DURING CONSTRUCTION INCLUDING BUT NOT LIMITED TO SHEETING, SHORING, AND GUYING STRUCTURES, BARRIERS, AND SIGNAGE. 9.DO NOT SCALE THE DRAWINGS. DIMENSION STRINGS HAVE BEEN PROVIDED AND REPRESENT THE ACTUAL MEASUREMENT AS NOTED. CLIENT: 24 x 36 DateJob Number CONTRACTOR:DESIGNER: 9/ 1 0 / 2 0 2 4 9 : 2 7 : 5 5 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t NIKO'S RESIDENCE NIKO'S RESIDENCE 09/10/2024Project # 56 School St, Salem, MA 01970 PERMIT SET 09/10/2024 NIKOLLAQ PAPA SCOPE: PROPOSED CHANGE OF OCCUPANCY 56 School St, Salem, MA 01970 PHONE # 978-893-9746 PARID & MIKAELA LLC ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 SCOPE: PROPOSED CHANGE OF OCCUPANCY & NEW DORMER DRAWING LIST A0.0 COVER SHEET & PROJECT INFORMATION A0.1 PROPOSED ARCHITECTURAL SITE PLAN A1.1 PROPOSED FLOOR PLANS AEX1.1 EXISTING FLOOR PLANS AEX1.2 EXISTING FLOOR PLANS AEX2.0 EXISTING ELEVATIONS ASR1.1 SELECTIVE REMOVAL PLAN - BASEMENT & FIRST FLOOR A1.0 PROPOSED FLOOR PLANS A2.0 PROPOSED EXTERIOR ELEVATIONS A3.1 PROPOSED PERSPECTIVE VIEWS S1.0 PROPOSED FRAMING PLANS S1.1 PROPOSED FRAMING PLANS S1.2 PROPOSED FRAMING PLANS & SECTION DETAILS LOCUS MAP 56 School St, Salem, MA 01970 DN DN UP UP DN DN DN DN D UP UP UP AEX2.0 1 120 SF SUNROOM 106 35 SF BATHROOM 105 189 SF KITCHEN 104 188 SF LIVING AREA 101 155 SF DINING AREA 102 156 SF LIVING AREA 10357 SF STAIR 100 AEX2.0 3 AEX2.0 2 AEX2.04 AEX2.0 1 W/D 95 SF BATHROOM 20287 SF BEDROOM-2 203 12 SF CLOSET 203A 12 SF CLOSET 204A 32 SF HALL 201 5 SF CLOSET 113 122 SF OFFICE 200 149 SF PRIMARY BEDROOM 204 142 SF BEDROOM-1 205 9 SF CLOSET 205A 67 SF STAIR 118 AEX2.0 3 AEX2.0 2 AEX2.04 EXISTING MAIN BEAM AEX2.0 1 AEX2.0 3 AEX2.0 2 AEX2.04 CONSTRUCTION MANAGER: 24 x 36 Sc a l e Da t e 1/ 4 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 8 : 0 9 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t AEX1.1 EX I S T I N G F L O O R P L A N S NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 09 / 1 0 / 2 0 2 4 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 1/4" = 1'-0"2 EXISTING 1ST FLOOR PLAN 1/4" = 1'-0"3 EXISTING 2ND FLOOR PLAN 1/4" = 1'-0"1 EXISTING BASEMENT FLOOR PLAN PARID & MIKAELA LLC PERMIT SET 09/10/2024 DN AEX2.0 1 ROOF BELOW UNFINISHED ATTIC TO REMAIN THE SAME AEX2.0 3 AEX2.0 2 AEX2.04 AEX2.0 1 AEX2.0 3 AEX2.0 2 AEX2.04 24 x 36 Sc a l e Da t e 1/ 4 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 8 : 1 0 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t AEX1.2 EX I S T I N G F L O O R P L A N S 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"1 EXISTING ATTIC FLOOR PLAN 1/4" = 1'-0"2 EXISTING TOP OF THE ROOF CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" GROUND LEVEL -3' -6" PROPOSED NEW ROOF 28' -7" T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" PROPOSED NEW ROOF 28' -7" T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" GROUND LEVEL -3' -6" PROPOSED NEW ROOF 28' -7" T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" GROUND LEVEL -3' -6" PROPOSED NEW ROOF 28' -7" 24 x 36 Sc a l e Da t e 1/ 4 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 8 : 1 4 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t AEX2.0 EX I S T I N G E L E V A T I O N S 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"1 EXISTING FRONT ELEVATION 1/4" = 1'-0"3 EXISTING REAR ELEVATION 1/4" = 1'-0"2 EXISTING LEFT ELEVATION 1/4" = 1'-0"4 EXISTING RIGHT ELEVATION CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 DN UP UP DN DN UP UP DN DN D UP DEMO LEGEND: EXISTING WALL TO REMAIN DEMO WALL OR COMPONENT DEMO DOOR DEMO NOTE: DEMO STAIR FROM BASEMENT TO 1ST FLOOR (ELECTRIC PANEL TO BE ON EACH UNIT HEATING/COOLING WILL BE ELECTRIC MINISPLITC) DEMO NOTE: DEMO STAIR FROM BASEMENT TO 1ST FLOOR (ELECTRIC PANEL TO BE ON EACH UNIT HEATING/COOLING WILL BE ELECTRIC MINISPLITC) ROOF BELOW 24 x 36 Sc a l e Da t e 1/ 4 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 8 : 1 5 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t ASR1.1 SE L E C T I V E R E M O V A L PL A N - B A S E M E N T & FI R S T F L O O R 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"2 LEVEL 1 -SELECTIVE REMOVAL PLAN 1/4" = 1'-0"1 BASEMENT FLOOR PLAN 1/4" = 1'-0"3 LEVEL 2 -SELECTIVE REMOVAL PLAN CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 HO U S E F O O T P R I N T PROPERTY LINE SCHOOL STREET REQUIRED SETBACKS R E Q . S E T B A C K S 1 0 ' - 0 " REQ. SETBACKS30'-0" R E Q . S E T B A C K S 1 0 ' - 0 " REQ. SETBACKS 15'-0" 1 1 ' - 4 3 / 4 " 2 4 ' - 6 " 4'-4" 10'-0" 6 ' - 7 " 14'-4" U P PROPOSED NEW DECK 3 ' - 8 " 2 0 ' - 1 0 " 1 ' - 0 " . 24 x 36 Sc a l e Da t e 1/ 8 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 7 : 5 6 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t A0.1 PR O P O S E D AR C H I T E C T U R A L S I T E PL A N 09 / 1 0 / 2 0 2 4 CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 UP DN DN UP DN DN D UP FLOOR PLAN LEGEND: EXISTING WALL TO REMAIN PROPOSED NEW WALL NO WORK THIS AREA EXISTING DOOR NEW DOOR SP PHOTO SENSITIVE SMOKE DETECTOR (HARD WIRE) S CO COMBINATION PHOTO SENSITIVE SMOKE/CARBON MONOXIDE DETECTOR (HARD WIRE) HEAT DETECTOR (HARD WIRE)HT EXISTING MAIN BEAM A2.0 3 GENERAL CONSTRUCTION NOTES: 1.USE METAL JOISTS AND BEAM HANGERS FOR ALL FLUSH FRAMED CONDITIONS, USE STEEL CONNECTION ASSEMBLIES TO FULLY DEVELOPE THE CONNECTED MEMBERS. ALL BEAMS AND LINTELS TO BE CONNECTED TO WOOD POSTS WITH MINIMUM 12 GA. STEEL POST CAPS BY "SIMPSON" OR EQUAL. 2.THE MINIMUM INTERIOR HEADER SIZE IS 2 @ 2X6 TYPICAL, UNLESS NOTED OTHERWISE. (U.N.O) 3.THE MINIMUM EXTERIOR HEADER SIZE IS 3 @ 2X8 TYPICAL, U.N.O. 4.ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED 5.ALL STUD WALL DIMENSIONS ARE TO FACE OF STUD U.N.O. MASONRY/CONCRETE DIMENSIONS ARE TO FACE OF MASONRY/CONCRETE. 6.CEILING HEIGHTS ARE SUBFLOOR TO UNDERSIDE OF FINISHED CEILING. 7.ALL EXTERIOR STUDS ARE 5-1/2" U.N.O & ALL INTERIOR STUDS ARE 3-1/2" U.N.O. 8.REFERT O STRUCTURAL DRAWINGS & SPECIFICATIONS FOR ADDITIONAL, STRUCTURAL, INFORMATION. CONTACT ARCHITECT WITH ANY FOUND DISCREPENCIES OR CONFLICTS. 9.ALL DOORS AND CASED OPENINGS ARE TO BE LOCATED 5" FROM ADJACENT WALL FRAMING TO DOOR OPENING OR CENTERED ON THE WALL WHERE LOCATED, U.N.O. 10.INTERIOR THRESHOLDS AT WOOD/TILE & WOOD/CARPET TRANSITION TO BE WOOD TO MATCH WOOD FLOORING. 11.ALL CLOTHING CLOSETS TO HAVE A HANGING ROD AT 5'-6" AFF WITH EDGEBANDED PAINTED PLYWOOD SHELF ABOVE U.N.O. LINEN CLOSETS TO HAVE (5) 16" DEEP EDGEBANDED PAINTED PLYWOOD SHELVES ON LEDGERS, FINISHES WITHIN CLOSETS TO MATCH ADJACENT ROOMS. 12.ALL WINDOW AND DOOR HEIGHTS TO MATCH U.N.O. (ALIGN FINISH HEAD TRIM, TYPICAL). 13. THERE IS NO STRUCTURAL CHANGES OF THE HOUSE 3' - 0 " 1' - 8 " 9' - 1 0 1 / 2 " 13'-0 3/4" 12'-1 3/4" 8'-7 3/4" 3'-6" 11 ' - 1 1 / 2 " TV 137 SF PRIMARY BEDROOM 102 14 SF CLOSET 102A 123 SF BEDROOM-1 103 392 SF KITCHEN 104 35 SF BATHROOM 105 Redundant Room LIVING/DINING 101 56 SF STAIR 100 13 SF CLOSET 103A 36 X 8 0 120 SF SUNROOM 106 43 1/2"X62 1/2" WINDOW SIZE, MEETS EGRESS REQUIREMENTS 43 1/2"X62 1/2" WINDOW SIZE, MEETS EGRESS REQUIREMENTS SCO SP SP SCO 12 SF LAUNDRY 107 UP DECK ABOVE EQ EQ EQ 7'-10" 9' - 6 " 14 ' - 4 1 / 4 " A2.0 3 A2.0 2 A2.04 A2.0 1 SP SCO 3'-0" 145 SF BEDROOM-2 203 130 SF BEDROOM-1 201 98 SF BATHROOM 205 134 SF LEAVING/DINING AREA 204 9 SF CLOSET 203A 125 SF KITCHEN 202 40 SF STAIR 200 31"X58" WINDOW SIZE, MEETS EGRESS REQUIREMENTS 31"X58" WINDOW SIZE, MEETS EGRESS REQUIREMENTS SP PROPOSED NEW DECK DN 14 ' - 4 " 10 ' - 0 " 24'-6" 4'-0" A2.0 3 A2.0 2 A2.04 4' - 4 " 3'-0" 3' - 0 " 2' - 0 " TV SCO 17 SF CLOSET 201A 3' - 2 " 4'-3 1/4" 24 x 36 Sc a l e Da t e 1/ 4 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 7 : 5 7 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t A1.0 PR O P O S E D F L O O R PL A N S 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"1 BASEMENT -PROPOSED FLOOR PLAN 1/4" = 1'-0"2 LEVEL 1 -PROPOSED FLOOR PLAN 1/4" = 1'-0"3 LEVEL 2 -PROPOSED FLOOR PLAN CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 DN A2.0 3 A2.0 2 A2.04 A2.0 1 ROOF BELOW EQ EQ EQ EQ 12 ' - 6 " 2' - 1 1 " 5' - 0 1 / 2 " 12 ' - 0 " 13'-0 3/4" 55 SF BATHROOM 132 32 SF CLOSET 133 218 SF PRIMARY BEDROOM 134 31 SF STORAGE 135 131 SF BEDROOM-3 136 31 SF CLOSET 137 85 SF STAIR 138 EGRESS WINDOW 31"X58"31"X58" 31 " X 5 8 " 31 " X 5 8 " 31 " X 5 8 " 31 " X 5 8 " EGRESS WINDOW A2.0 3 A2.0 2 A2.04 A2.0 1 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" 4" / 1'-0" FLOOR PLAN LEGEND: EXISTING WALL TO REMAIN PROPOSED NEW WALL NO WORK THIS AREA EXISTING DOOR NEW DOOR SP PHOTO SENSITIVE SMOKE DETECTOR (HARD WIRE) S CO COMBINATION PHOTO SENSITIVE SMOKE/CARBON MONOXIDE DETECTOR (HARD WIRE) HEAT DETECTOR (HARD WIRE)HT GENERAL CONSTRUCTION NOTES: 1.USE METAL JOISTS AND BEAM HANGERS FOR ALL FLUSH FRAMED CONDITIONS, USE STEEL CONNECTION ASSEMBLIES TO FULLY DEVELOPE THE CONNECTED MEMBERS. ALL BEAMS AND LINTELS TO BE CONNECTED TO WOOD POSTS WITH MINIMUM 12 GA. STEEL POST CAPS BY "SIMPSON" OR EQUAL. 2.THE MINIMUM INTERIOR HEADER SIZE IS 2 @ 2X6 TYPICAL, UNLESS NOTED OTHERWISE. (U.N.O) 3.THE MINIMUM EXTERIOR HEADER SIZE IS 3 @ 2X8 TYPICAL, U.N.O. 4.ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED 5.ALL STUD WALL DIMENSIONS ARE TO FACE OF STUD U.N.O. MASONRY/CONCRETE DIMENSIONS ARE TO FACE OF MASONRY/CONCRETE. 6.CEILING HEIGHTS ARE SUBFLOOR TO UNDERSIDE OF FINISHED CEILING. 7.ALL EXTERIOR STUDS ARE 5-1/2" U.N.O & ALL INTERIOR STUDS ARE 3-1/2" U.N.O. 8.REFERT O STRUCTURAL DRAWINGS & SPECIFICATIONS FOR ADDITIONAL, STRUCTURAL, INFORMATION. CONTACT ARCHITECT WITH ANY FOUND DISCREPENCIES OR CONFLICTS. 9.ALL DOORS AND CASED OPENINGS ARE TO BE LOCATED 5" FROM ADJACENT WALL FRAMING TO DOOR OPENING OR CENTERED ON THE WALL WHERE LOCATED, U.N.O. 10.INTERIOR THRESHOLDS AT WOOD/TILE & WOOD/CARPET TRANSITION TO BE WOOD TO MATCH WOOD FLOORING. 11.ALL CLOTHING CLOSETS TO HAVE A HANGING ROD AT 5'-6" AFF WITH EDGEBANDED PAINTED PLYWOOD SHELF ABOVE U.N.O. LINEN CLOSETS TO HAVE (5) 16" DEEP EDGEBANDED PAINTED PLYWOOD SHELVES ON LEDGERS, FINISHES WITHIN CLOSETS TO MATCH ADJACENT ROOMS. 12.ALL WINDOW AND DOOR HEIGHTS TO MATCH U.N.O. (ALIGN FINISH HEAD TRIM, TYPICAL). 13. THERE IS NO STRUCTURAL CHANGES OF THE HOUSE 24 x 36 Sc a l e Da t e 1/ 4 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 7 : 5 8 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t A1.1 PR O P O S E D F L O O R PL A N S 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"1 ATTIC -PROPOSED FLOOR PLAN 1/4" = 1'-0"2 PROPOSED TOP OF THE ROOF CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 SP SP SCO T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" GROUND LEVEL -3' -6" THE SCOPE OF EXTERIOR WORK 31"X58"31"X58" PROPOSED NEW ROOF 28' -7" T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" GROUND LEVEL -3' -6" THE SCOPE OF EXTERIOR WORK PROPOSED NEW ROOF 28' -7" T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" GROUND LEVEL -3' -6" THE SCOPE OF EXTERIOR WORK PROPOSED NEW ROOF 28' -7" 31"X58"31"X58"31"X58"31"X58" T.O. 1ST FLOOR SLAB 0' -0" T.O. 2ND FLOOR SLAB 8' -10" ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" GROUND LEVEL -3' -6" PROPOSED NEW ROOF 28' -7" 24 x 36 Sc a l e Da t e 1/ 4 " = 1 ' -0" 9/ 1 0 / 2 0 2 4 9 : 2 8 : 0 3 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t A2.0 PR O P O S E D E X T E R I O R EL E V A T I O N S 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"3 PROPOSED REAR ELEVATION 1/4" = 1'-0"2 PROPOSED LEFT ELEVATION 1/4" = 1'-0"4 PROPOSED RIGHT ELEVATION 1/4" = 1'-0"1 PROPOSED FRONT ELEVATION CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 24 x 36 Sc a l e Da t e 9/ 1 0 / 2 0 2 4 9 : 2 8 : 0 8 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t A3.1 PR O P O S E D PE R S P E C T I V E V I E W S 09 / 1 0 / 2 0 2 4 3 REAR-RIGHT PERSPEECTIVE VIEW 1 FRONT-LEFT PERSPECTIVE VIEW 2 REAR-LEFT PERSPECTIVE VIEW 4 FRONT-RIGHT PERSPECTIVE VIEW CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 UP DN DN UP DN EXISTING DECK ABOVE TYP SONATUBE 5 S1.2 Sim FLOOR JOIST BEARING WALL FRAMING LEGEND: ROOF JOIST CELING JOIST EXISTING TO REMAIN HEADERS 6X6 PT POSTS 6" 6" 6" 9' - 6 " 6"7'-10"7'-10"7'-10"6" DECK ABOVE 6" 4' - 4 " 9' - 6 " 14 ' - 4 " 24'-6" 9'-6 3/4"3'-6 1/4"7'-2"3'-3" 5 S1.2 Sim BUILDING ENCLOSURE NOTES: 1.MAINTAIN CONTINUITY OF ALL EXTERIOR ENVELOPE CONTROL LAYERS (WEATHER BARRIER, AIR BARRIER, INSULATION, VAPOR RETARDER, AND ALL ASSOCIATED TRANSITIONS) THROUGHOUT THE ENTIRE BUILDING. 2.MAINTAIN FULL CONTINUITY AT TRANSITIONS BETWEEN BUILDING ENVELOPE COMPONENTS SUCH AS WALL-TO-ROOF INTERSECTIONS, WALL- TO-FLOOR OR FOUNDATION INTERSECTIONS, OR WALL-TO-WALL INTERSECTIONS. 3.TRANSITIONS INCLUDE, BUT ARE NOT LIMITED TO, ATTICS, MECHANICAL SPACES, SOFFITS, EXHAUST AND INTAKE AIR VENTS, PIPE AND CABLE PENETRATIONS, ACCESS PANELS, ELECTRICAL RECEPTACLES, BASEBOARDS, DOORS AND WINDOW INTERFACE, TOP OF WALLS, HEADERS & RIM JOISTS, INTERSECTIONSOF PLYWOOD SUBFLOORS, EXTERIOR WALL SHEATHING, UNDERSIDE OF ROOF FRAMING, UNDERSIDE OF FLOOR FRAMING EXPOSED TO THE WEATHER FOUNDATION WALLS, AND FLOOR SLABS. 4.EXTERIOR THERMAL ENVELOPE INSULATION SHALL BE INSTALLED IN SUBSTANTIAL CONTACT AND CONTINUOUS ALIGNMENT WITH BUILDING ENVELOPE AIR BARRIER. BREAKS OR JOINTS IN THE AIR BARRIER SHALL BE FILLED OR SEALED. AIR PERMEABLE INSULATION SHALL NOT BE USED AS A SEALING MATERIAL. AIR PERMEABLE INSULATION SHALL BE INSIDE OF AIR BARRIER. 5.ENSURE THAT THERE ARE NO THERMAL BRIDGES BETWEEN SYSTEM COMPONENTS. 6.THERMAL BARRIER-ALL FOAM PLASTIC TO BE SEPARATED FROM BUILDING INTERIOR BY AN APPROVED THERMAL BARRIER PER IRC R316.4. MAINTAIN CONTINUITY OF THERMAL BARRIER AT ALL ASSEMBLY TRANSITIONS. 24 x 36 Sc a l e Da t e As i n d i c a t e d 9/ 1 0 / 2 0 2 4 9 : 2 8 : 1 5 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t S1.0 PR O P O S E D F R A M I N G PL A N S 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"1 BASEMENT -PROPOSED FOUNDATION PLAN 1/4" = 1'-0"2 LEVEL 1 -PROPOSED FRAMING PLAN STRUCTURAL NOTES GENERAL 1. CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING CODE, NINTH EDITION (FOR ONE AND TWO FAMILY DWELLINGS) AND THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC 2015) 2. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE STRUCTURAL DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUBSTITUTIONS OF STRUCTURAL MATERIALS OR DETAILS FROM THOSE INDICATED ON THE DRAWINGS MAY BE MADE ONLY WITH THE PRIOR APPROVAL OF THE ENGINEER OR ARCHITECT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, AND COORDINATION OF TRADES. FOUNDATIONS 1. FOUNDATIONS SHALL BEAR UNDISTURBED NATIVE SOIL OR COMPACTED STRUCTURAL BACKFILL. NO FOUNDATION SHALL BE PLACED ON FROZEN SUBGRADE. CONTRACTOR SHALL INFORM THE STRUCTURAL ENGINEER OF ANY UNUSUAL OR DOUBTFUL SOIL CONDITIONS. 2. PRESUMED SOIL BEARING CAPACITY IS 3000 PSF. 3. BOTTOM OF EXTERIOR FOOTINGS SHALL BE SET AT LEAST 4 FEET BELOW FINAL GRADE (UNLESS FOOTING IS ON LEDGE). 4. IF STRUCTURAL FILL IS NEEDED, PLACE STRUCTURAL FILL IN 8-INCH LIFTS AND COMPACT TO 95% DENSITY AS DETERMINED BY MODIFIED PROCTOR TEST –ASTM D1557. CONCRETE 1. CONCRETE FOR FOUNDATION WALLS SHALL HAVE A COMPRESSIVE STRENGTH OF AT LEAST 3000 PSI; CONCRETE FOR SLAB SHALL HAVE A COMPRESSIVE STRENGTH OF AT LEAST 4000 PSI. CONCRETE SHALL BE AIR-ENTRAINED. 2. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE’S (ACI) “BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE”(ACI 318), “SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS”(ACI 301) AND “RECOMMENDED PRACTICE FOR COLD WEATHER CONCRETING”(ACI 306). 3. REINFORCING BARS SHALL BE CONTINUOUS AROUND CORNERS 4. NO CONCRETE SHALL BE PLACED ON FROZEN SUBGRADE. 5. ANCHOR BOLTS SHALL BE 1/2 INCH DIAMETER, 12 INCHES LONG, SPACED AT 48 INCH MAXIMUM AND 12 INCHES MAXIMUM FROM CORNERS AND ENDS. 6. VERIFY ALL PLUMBING, MECHANICAL, AND ELECTRICAL REQUIREMENTS BEFORE POURING CONCRETE. 7. PROVIDE 8 INCHES OF FREE-DRAINING COMPACTED GRAVEL AND 10 MIL POLYETHYLENE VAPOR BARRIER UNDER SLABS ON GRADE. 8. PROVIDE CONTROL JOINTS IN SLABS TO CONTROL CRACKING. SAW CUT TO A DEPTH OF 1/4 SLAB THICKNESS (1 INCH MINIMUM). CONTROL JOINTS SHOULD BE SAW CUT AS SOON AS PRACTICAL. STRUCTURAL STEEL 1. STRUCTURAL STEEL WORK SHALL CONFORM TO “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”(AISC 1989), “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES”(AISC), AND “STRUCTURAL WELDING CODE”(AWS D1.1) 2. STRUCTURAL STEEL SHALL BE DETAILED IN ACCORDANCE WITH “DETAILING FOR STEEL CONSTRUCTION”(AISC). 3. WIDE FLANGE STEEL BEAMS SHALL CONFORM TO ASTM A572 (Fy = 50 KSI). 4. STEEL PIPE SECTIONS SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B. HSS STEEL TUBE SHALL CONFORM TO ASTM A500 GRADE B (Fy = 46 KSI) 5. PLATES AND ANGLES SHALL CONFORM TO ASTM A36. 6. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325. MINIMUM DIAMETER SHALL BE 3/4 INCH. 7. WELDS SHALL FULLY DEVELOP THE STRENGTH OF THE MATERIALS BEING WELDED. FILLET WELDS SHALL BE 1/4 INCH MINIMUM. 8. PROVIDE TEMPORARY ERECTION BRACING AS REQUIRED DURING STEEL ERECTION. FRAMING SHALL BE TRUE AND PLUMB BEFORE CONNECTIONS ARE FINALLY BOLTED OR WELDED 9. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO STEEL FABRICATION. 10. STRUCTURAL STEEL AND STEEL JOISTS SHALL BE PAINTED IN THE SHOP WITH ONE COAT OF PRIMER. 11. STEEL SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. 12. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY PROPOSED HOLES OR NOTCHES IN ANY STEEL MEMBER. WOOD 1. FRAMING LUMBER SHALL BE SPRUCE-PINE-FIR #2 OR BETTER. 2. ALL POSTS SHALL BE FULLY BLOCKED BETWEEN FLOORS WITH THE GRAIN OF BLOCKING IN A VERTICAL ORIENTATION. 3. PROVIDE AN ADDITIONAL JOIST UNDER ALL INTERIOR WALLS RUNNING PARALLEL TO FLOOR JOISTS. PROVIDE BLOCKING BETWEEN FLOOR JOISTS FOR ALL INTERIOR WALLS RUNNING PERPENDICULAR TO FLOOR JOISTS. 4. PROVIDE BRIDGING AT MID-SPAN OF ALL JOISTS WITHOUT CEILING BELOW. 5. LAMINATED VENEER LUMBER (LVL) SHALL HAVE A MODULUS OF ELASTICITY (E) OF 2,000,000 PSI AND AN ALLOWABLE BENDING STRESS (Fb) OF 3,100 PSI. LVL’S SHALL BE INSTALLED AND FASTENED TOGETHER PER MANUFACTURER’S RECOMMENDATIONS. 6. CONFORM TO MANUFACTURER’S RECOMMENDATIONS WITH RESPECT TO INSTALLATION, CUTTING, NOTCHING, AND FASTENING OF ALL ENGINEERED LUMBER. 7. PROVIDE SIMPSON H2.5 HURRICANE TIES AT EVERY RAFTER/ TOP PLATE CONNECTION. 8. CONNECT OPPOSING RAFTERS TOGETHER WITH COLLAR TIES OR WITH STEEL STRAP TIES OVER THE RIDGE (SIMPSON LSTA24). 9. EXTERIOR WALLS SHALL BE CONSTRUCTED USING THE CS-WSP BRACING METHOD (CONTINUOUSLY SHEATHED WOOD STRUCTURALPANELS) IN ACCORDANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE. SPECIFIC REQUIREMENTS INCLUDE: SHEATHING APPLIED WITH 8d COMMON NAILS SPACED AT 6 INCHES ALONG EDGES AND AT 12 INCHES ELSEWHERE. 10. FOR EXTERIOR BRACED WALLS, HORIZONTAL JOINTS IN THE BRACED WALL PANELS ARE REQUIRED TO BE BLOCKED (2015 IRC SECTION R602.10.10). 11. WHERE RAFTERS ARE SUPPORTED ON BRACED WALLS, BLOCKING IS REQUIRED BETWEEN THE RAFTERS IN ACCORDANCE WITH SECTION R602.10.8.2 OF THE 2015 IRC. 12. EACH DECK IS TO BE LATERALLY TIED TO THE MAIN STRUCTURE IN ACCORDANCE WITH SECTION R507.2.4 OF THE 2015 INTERNATIONAL RESIDENTIAL CODE. 13. DESIGN AND DETAILING OF DECK RAILING IS THE RESPONSIBILITY OF THE CONTRACTOR. REFER TO THE 2015 INTERNATIONAL RESIDENTIAL CODE AND THE PRESCRIPTIVE RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE PUBLISHED BY THE AMERICAN FOREST AND PAPER ASSOCIATION. CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 DN DN D UP FLOOR JOIST BEARING WALL FRAMING LEGEND: ROOF JOIST CELING JOIST EXISTING TO REMAIN HEADERS (3) 2X10 HEADERS 2 S1.2 2X 1 0 @ 1 6 " O . C . F L O O R J O I S T S (3 ) 2 X 1 0 H E A D E R S (3 ) 2 X 1 0 H E A D E R S BUILDING ENCLOSURE NOTES: 1.MAINTAIN CONTINUITY OF ALL EXTERIOR ENVELOPE CONTROL LAYERS (WEATHER BARRIER, AIR BARRIER, INSULATION, VAPOR RETARDER, AND ALL ASSOCIATED TRANSITIONS) THROUGHOUT THE ENTIRE BUILDING. 2.MAINTAIN FULL CONTINUITY AT TRANSITIONS BETWEEN BUILDING ENVELOPE COMPONENTS SUCH AS WALL-TO-ROOF INTERSECTIONS, WALL- TO-FLOOR OR FOUNDATION INTERSECTIONS, OR WALL-TO-WALL INTERSECTIONS. 3.TRANSITIONS INCLUDE, BUT ARE NOT LIMITED TO, ATTICS, MECHANICAL SPACES, SOFFITS, EXHAUST AND INTAKE AIR VENTS, PIPE AND CABLE PENETRATIONS, ACCESS PANELS, ELECTRICAL RECEPTACLES, BASEBOARDS, DOORS AND WINDOW INTERFACE, TOP OF WALLS, HEADERS & RIM JOISTS, INTERSECTIONSOF PLYWOOD SUBFLOORS, EXTERIOR WALL SHEATHING, UNDERSIDE OF ROOF FRAMING, UNDERSIDE OF FLOOR FRAMING EXPOSED TO THE WEATHER FOUNDATION WALLS, AND FLOOR SLABS. 4.EXTERIOR THERMAL ENVELOPE INSULATION SHALL BE INSTALLED IN SUBSTANTIAL CONTACT AND CONTINUOUS ALIGNMENT WITH BUILDING ENVELOPE AIR BARRIER. BREAKS OR JOINTS IN THE AIR BARRIER SHALL BE FILLED OR SEALED. AIR PERMEABLE INSULATION SHALL NOT BE USED AS A SEALING MATERIAL. AIR PERMEABLE INSULATION SHALL BE INSIDE OF AIR BARRIER. 5.ENSURE THAT THERE ARE NO THERMAL BRIDGES BETWEEN SYSTEM COMPONENTS. 6.THERMAL BARRIER-ALL FOAM PLASTIC TO BE SEPARATED FROM BUILDING INTERIOR BY AN APPROVED THERMAL BARRIER PER IRC R316.4. MAINTAIN CONTINUITY OF THERMAL BARRIER AT ALL ASSEMBLY TRANSITIONS. (3) 2X10 HEADER 2X10 PT @ 16" O.C. 2" x 12" PT STRINGERS @ 12" O.C. 4' - 4 " 10 ' - 0 " 24'-6" 3'-2"21'-4" 10 ' - 0 " 4' - 4 " 14 ' - 4 " 2" x 10" PT LEDGER BOARD LAGGED TO SILL WITH 1/2" x 6" LAG BOLTS @ 12" O.C. (2 ) 2 " x 1 0 " P T (2) 2" x 10" PT (2 ) 2 " x 1 0 " P T 2" x 10" GALV. HANGER (TYP) BOTH ENDS OF JOIST (2) 1/2" x 10" CARRIAGE BOLTS AT EACH POST 2 S1.2 24 x 36 Sc a l e Da t e As i n d i c a t e d 9/ 1 0 / 2 0 2 4 9 : 2 8 : 1 6 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t S1.1 PR O P O S E D F R A M I N G PL A N S 09 / 1 0 / 2 0 2 4 1/4" = 1'-0"2 ATTIC -PROPOSED FRAMING PLAN STRUCTURAL NOTES GENERAL 1. CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING CODE, NINTH EDITION (FOR ONE AND TWO FAMILY DWELLINGS) AND THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC 2015) 2. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE STRUCTURAL DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUBSTITUTIONS OF STRUCTURAL MATERIALS OR DETAILS FROM THOSE INDICATED ON THE DRAWINGS MAY BE MADE ONLY WITH THE PRIOR APPROVAL OF THE ENGINEER OR ARCHITECT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, AND COORDINATION OF TRADES. FOUNDATIONS 1. FOUNDATIONS SHALL BEAR UNDISTURBED NATIVE SOIL OR COMPACTED STRUCTURAL BACKFILL. NO FOUNDATION SHALL BE PLACED ON FROZEN SUBGRADE. CONTRACTOR SHALL INFORM THE STRUCTURAL ENGINEER OF ANY UNUSUAL OR DOUBTFUL SOIL CONDITIONS. 2. PRESUMED SOIL BEARING CAPACITY IS 3000 PSF. 3. BOTTOM OF EXTERIOR FOOTINGS SHALL BE SET AT LEAST 4 FEET BELOW FINAL GRADE (UNLESS FOOTING IS ON LEDGE). 4. IF STRUCTURAL FILL IS NEEDED, PLACE STRUCTURAL FILL IN 8-INCH LIFTS AND COMPACT TO 95% DENSITY AS DETERMINED BY MODIFIED PROCTOR TEST –ASTM D1557. CONCRETE 1. CONCRETE FOR FOUNDATION WALLS SHALL HAVE A COMPRESSIVE STRENGTH OF AT LEAST 3000 PSI; CONCRETE FOR SLAB SHALL HAVE A COMPRESSIVE STRENGTH OF AT LEAST 4000 PSI. CONCRETE SHALL BE AIR-ENTRAINED. 2. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE’S (ACI) “BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE”(ACI 318), “SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS”(ACI 301) AND “RECOMMENDED PRACTICE FOR COLD WEATHER CONCRETING”(ACI 306). 3. REINFORCING BARS SHALL BE CONTINUOUS AROUND CORNERS 4. NO CONCRETE SHALL BE PLACED ON FROZEN SUBGRADE. 5. ANCHOR BOLTS SHALL BE 1/2 INCH DIAMETER, 12 INCHES LONG, SPACED AT 48 INCH MAXIMUM AND 12 INCHES MAXIMUM FROM CORNERS AND ENDS. 6. VERIFY ALL PLUMBING, MECHANICAL, AND ELECTRICAL REQUIREMENTS BEFORE POURING CONCRETE. 7. PROVIDE 8 INCHES OF FREE-DRAINING COMPACTED GRAVEL AND 10 MIL POLYETHYLENE VAPOR BARRIER UNDER SLABS ON GRADE. 8. PROVIDE CONTROL JOINTS IN SLABS TO CONTROL CRACKING. SAW CUT TO A DEPTH OF 1/4 SLAB THICKNESS (1 INCH MINIMUM). CONTROL JOINTS SHOULD BE SAW CUT AS SOON AS PRACTICAL. STRUCTURAL STEEL 1. STRUCTURAL STEEL WORK SHALL CONFORM TO “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”(AISC 1989), “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES”(AISC), AND “STRUCTURAL WELDING CODE”(AWS D1.1) 2. STRUCTURAL STEEL SHALL BE DETAILED IN ACCORDANCE WITH “DETAILING FOR STEEL CONSTRUCTION”(AISC). 3. WIDE FLANGE STEEL BEAMS SHALL CONFORM TO ASTM A572 (Fy = 50 KSI). 4. STEEL PIPE SECTIONS SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B. HSS STEEL TUBE SHALL CONFORM TO ASTM A500 GRADE B (Fy = 46 KSI) 5. PLATES AND ANGLES SHALL CONFORM TO ASTM A36. 6. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325. MINIMUM DIAMETER SHALL BE 3/4 INCH. 7. WELDS SHALL FULLY DEVELOP THE STRENGTH OF THE MATERIALS BEING WELDED. FILLET WELDS SHALL BE 1/4 INCH MINIMUM. 8. PROVIDE TEMPORARY ERECTION BRACING AS REQUIRED DURING STEEL ERECTION. FRAMING SHALL BE TRUE AND PLUMB BEFORE CONNECTIONS ARE FINALLY BOLTED OR WELDED 9. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO STEEL FABRICATION. 10. STRUCTURAL STEEL AND STEEL JOISTS SHALL BE PAINTED IN THE SHOP WITH ONE COAT OF PRIMER. 11. STEEL SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. 12. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY PROPOSED HOLES OR NOTCHES IN ANY STEEL MEMBER. WOOD 1. FRAMING LUMBER SHALL BE SPRUCE-PINE-FIR #2 OR BETTER. 2. ALL POSTS SHALL BE FULLY BLOCKED BETWEEN FLOORS WITH THE GRAIN OF BLOCKING IN A VERTICAL ORIENTATION. 3. PROVIDE AN ADDITIONAL JOIST UNDER ALL INTERIOR WALLS RUNNING PARALLEL TO FLOOR JOISTS. PROVIDE BLOCKING BETWEEN FLOOR JOISTS FOR ALL INTERIOR WALLS RUNNING PERPENDICULAR TO FLOOR JOISTS. 4. PROVIDE BRIDGING AT MID-SPAN OF ALL JOISTS WITHOUT CEILING BELOW. 5. LAMINATED VENEER LUMBER (LVL) SHALL HAVE A MODULUS OF ELASTICITY (E) OF 2,000,000 PSI AND AN ALLOWABLE BENDING STRESS (Fb) OF 3,100 PSI. LVL’S SHALL BE INSTALLED AND FASTENED TOGETHER PER MANUFACTURER’S RECOMMENDATIONS. 6. CONFORM TO MANUFACTURER’S RECOMMENDATIONS WITH RESPECT TO INSTALLATION, CUTTING, NOTCHING, AND FASTENING OF ALL ENGINEERED LUMBER. 7. PROVIDE SIMPSON H2.5 HURRICANE TIES AT EVERY RAFTER/ TOP PLATE CONNECTION. 8. CONNECT OPPOSING RAFTERS TOGETHER WITH COLLAR TIES OR WITH STEEL STRAP TIES OVER THE RIDGE (SIMPSON LSTA24). 9. EXTERIOR WALLS SHALL BE CONSTRUCTED USING THE CS-WSP BRACING METHOD (CONTINUOUSLY SHEATHED WOOD STRUCTURALPANELS) IN ACCORDANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE. SPECIFIC REQUIREMENTS INCLUDE: SHEATHING APPLIED WITH 8d COMMON NAILS SPACED AT 6 INCHES ALONG EDGES AND AT 12 INCHES ELSEWHERE. 10. FOR EXTERIOR BRACED WALLS, HORIZONTAL JOINTS IN THE BRACED WALL PANELS ARE REQUIRED TO BE BLOCKED (2015 IRC SECTION R602.10.10). 11. WHERE RAFTERS ARE SUPPORTED ON BRACED WALLS, BLOCKING IS REQUIRED BETWEEN THE RAFTERS IN ACCORDANCE WITH SECTION R602.10.8.2 OF THE 2015 IRC. 12. EACH DECK IS TO BE LATERALLY TIED TO THE MAIN STRUCTURE IN ACCORDANCE WITH SECTION R507.2.4 OF THE 2015 INTERNATIONAL RESIDENTIAL CODE. 13. DESIGN AND DETAILING OF DECK RAILING IS THE RESPONSIBILITY OF THE CONTRACTOR. REFER TO THE 2015 INTERNATIONAL RESIDENTIAL CODE AND THE PRESCRIPTIVE RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE PUBLISHED BY THE AMERICAN FOREST AND PAPER ASSOCIATION. 1/4" = 1'-0"1 LEVEL 2 -PROPOSED FRAMING PLAN CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC PERMIT SET 09/10/2024 FLOOR JOIST BEARING WALL FRAMING LEGEND: ROOF JOIST CELING JOIST EXISTING TO REMAIN HEADERS 2 S1.2 2X 1 0 R O O F R A F T E R S @ 1 6 " O . C . 2X 1 0 R O O F R A F T E R S @ 1 6 " O . C . 2X12 RIDGE BEAM 2X COLLAR TIE @ EVERY RAFTER SIMPSON HURRICAN TIE @ ALL ROOF RAFTERS SIMPSON HANGERS @ EVERY RAFTER BUILDING ENCLOSURE NOTES: 1.MAINTAIN CONTINUITY OF ALL EXTERIOR ENVELOPE CONTROL LAYERS (WEATHER BARRIER, AIR BARRIER, INSULATION, VAPOR RETARDER, AND ALL ASSOCIATED TRANSITIONS) THROUGHOUT THE ENTIRE BUILDING. 2.MAINTAIN FULL CONTINUITY AT TRANSITIONS BETWEEN BUILDING ENVELOPE COMPONENTS SUCH AS WALL-TO-ROOF INTERSECTIONS, WALL- TO-FLOOR OR FOUNDATION INTERSECTIONS, OR WALL-TO-WALL INTERSECTIONS. 3.TRANSITIONS INCLUDE, BUT ARE NOT LIMITED TO, ATTICS, MECHANICAL SPACES, SOFFITS, EXHAUST AND INTAKE AIR VENTS, PIPE AND CABLE PENETRATIONS, ACCESS PANELS, ELECTRICAL RECEPTACLES, BASEBOARDS, DOORS AND WINDOW INTERFACE, TOP OF WALLS, HEADERS & RIM JOISTS, INTERSECTIONSOF PLYWOOD SUBFLOORS, EXTERIOR WALL SHEATHING, UNDERSIDE OF ROOF FRAMING, UNDERSIDE OF FLOOR FRAMING EXPOSED TO THE WEATHER FOUNDATION WALLS, AND FLOOR SLABS. 4.EXTERIOR THERMAL ENVELOPE INSULATION SHALL BE INSTALLED IN SUBSTANTIAL CONTACT AND CONTINUOUS ALIGNMENT WITH BUILDING ENVELOPE AIR BARRIER. BREAKS OR JOINTS IN THE AIR BARRIER SHALL BE FILLED OR SEALED. AIR PERMEABLE INSULATION SHALL NOT BE USED AS A SEALING MATERIAL. AIR PERMEABLE INSULATION SHALL BE INSIDE OF AIR BARRIER. 5.ENSURE THAT THERE ARE NO THERMAL BRIDGES BETWEEN SYSTEM COMPONENTS. 6.THERMAL BARRIER-ALL FOAM PLASTIC TO BE SEPARATED FROM BUILDING INTERIOR BY AN APPROVED THERMAL BARRIER PER IRC R316.4. MAINTAIN CONTINUITY OF THERMAL BARRIER AT ALL ASSEMBLY TRANSITIONS. DECK JOIST SEE FRAMING PLAN (2) 1/2" DIAMETER THROUGH-BOLTS WITH WASHER PT 6x6" POST COMPOSITE DECKING PT 2x10 RIM JOIST W/1xPVC FASCIA ON PT BLOCKING 3' - 6 " 0' - 0" 2 3 / 4 " 5" 2 1 / 4 " 5/8"X5" LONG LAG SCREW ON 2 SIDES RAILING POST 1' - 0" 2' - 0" 24" DIA. 'BIGFOOT' FOOTING GRADE ELEV. 12" DIA. SONOTUBE PT 6x6"STRUCTURAL POST 2X10 PT CBSQ POST BASE (INSTALL PER SIMPSON RECOM.) (2) 1/2" DIAMETER THROUGH-BOLTS WITH WASHER PRECOMPOSITE DECKING 3' - 6 " 2 3 / 4 " 5" 2 1 / 4 " MI N 8" . EXTERIOR INTERIOR EX T E R I O R W A L L EX T E R I O R W A L L EXISTING FLOOR JOISTDECK JOISTS SEE FRAMING PLAN SIMPSOM DTT1Z DECK TENSION TIE. INSTALL PER MANF. SPECS FIRST FLOORPROPOSED PRECOMPOSITE NEW DECK 1/2" x 6" LAG BOLTS @ 12" O.C. ATTIC FLOOR PLAN 17' -8" TOP OF ROOF 27' -2 5/16" PROPOSED NEW ROOF 28' -7" EXTERIOR WALL ASSEMBLY (TYP.)- •SIDING TO MATCH EXISTING •PAINTED WOOD TRIM, PTD. •SHEET METAL FLASHING AS REQUIRED •ALUM. CLAD WOOD WINDOWS AND DOORS WITH INSULATED GLAZING •VENTILATED UNDERLAYMENT (CEDAR BREATHER) •1/2" PLYWOOD SHEATHING WITH INTEGRAL WEATHER BARRIER •FRAMING- •NEW-2 X 6 @16" OC MAX •R-30 CLOSED CELL FOAM INSULATION •1/2" GYPSUM VENEER BASE W/ SKIMCOAT PLASTER, PTD. •WOOD TRIM, PTD ROOF ASSEMBLY (TYP.)- •ASPHALT SHINGLES (TO MATCH EXISTING HOUSE SHINGLES) •METAL DRIP EDGE AT PERIMETER OF ROOF •PAINTED WOOD, PTD EAVE, RAKE, SOFFIT TRIM •3/4" PLYWOOD SHEATHING UNDER ALL PVC •ICE AND WATER SHIELD OVER ENTIRE SURFACE OF SHEATHING •5/8" CDX PLYWOOD ROOF SHEATHING •ROOF FRAMING-REF STRUCTURAL •R-60 CLOSED-CELL INSULATION (AT UNDERSIDE OF ROOF SHEATHING) •2 X 12 CEILING JOISTS @ 16" OC MAX •1/2" GYPSUM VENEER BASE WITH PLASTER SKIMCOAT, PTD SIMPSON HANGERS @ EVERY RAFTER SIMPSON HURRICAN TIE @ ALL ROOF RAFTERS SIMPSON HURRICAN TIE @ ALL ROOF RAFTERS 2X12 RIDGE BEAM 2X COLLAR TIE @ EVERY RAFTER 2X10 CEILING JOIST @ 16" O.C. 2X10 ROOF RAFTERS @ 16" O.C. 24 x 36 Sc a l e Da t e As i n d i c a t e d 9/ 1 0 / 2 0 2 4 9 : 2 8 : 1 8 P M C: \ U s e r s \ O w n e r \ D e s k t o p \ P R O J E C T S \ 9 4 - 5 6 S c h o o l S t , S a l e m , M A 0 1 9 7 0 \ 5 6 S c h o o l S t r e e t S a l e m F i n a l P r o j e c t _ d e t a c h e d . r v t S1.2 PR O P O S E D F R A M I N G PL A N S & S E C T I O N DE T A I L S 09 / 1 0 / 2 0 2 4 PERMIT SET 09/10/2024 1/4" = 1'-0"1 ROOF -PROPOSED ROOF FRAMING PLAN STRUCTURAL NOTES GENERAL 1. CONSTRUCTION IS TO BE IN ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING CODE, NINTH EDITION (FOR ONE AND TWO FAMILY DWELLINGS) AND THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC 2015) 2. THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE STRUCTURAL DRAWINGS. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE AFFECTED WORK. ANY VARIATIONS OR SUBSTITUTIONS OF STRUCTURAL MATERIALS OR DETAILS FROM THOSE INDICATED ON THE DRAWINGS MAY BE MADE ONLY WITH THE PRIOR APPROVAL OF THE ENGINEER OR ARCHITECT. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, AND COORDINATION OF TRADES. FOUNDATIONS 1. FOUNDATIONS SHALL BEAR UNDISTURBED NATIVE SOIL OR COMPACTED STRUCTURAL BACKFILL. NO FOUNDATION SHALL BE PLACED ON FROZEN SUBGRADE. CONTRACTOR SHALL INFORM THE STRUCTURAL ENGINEER OF ANY UNUSUAL OR DOUBTFUL SOIL CONDITIONS. 2. PRESUMED SOIL BEARING CAPACITY IS 3000 PSF. 3. BOTTOM OF EXTERIOR FOOTINGS SHALL BE SET AT LEAST 4 FEET BELOW FINAL GRADE (UNLESS FOOTING IS ON LEDGE). 4. IF STRUCTURAL FILL IS NEEDED, PLACE STRUCTURAL FILL IN 8-INCH LIFTS AND COMPACT TO 95% DENSITY AS DETERMINED BY MODIFIED PROCTOR TEST –ASTM D1557. CONCRETE 1. CONCRETE FOR FOUNDATION WALLS SHALL HAVE A COMPRESSIVE STRENGTH OF AT LEAST 3000 PSI; CONCRETE FOR SLAB SHALL HAVE A COMPRESSIVE STRENGTH OF AT LEAST 4000 PSI. CONCRETE SHALL BE AIR-ENTRAINED. 2. CONCRETE WORK SHALL BE IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE’S (ACI) “BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE”(ACI 318), “SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS”(ACI 301) AND “RECOMMENDED PRACTICE FOR COLD WEATHER CONCRETING”(ACI 306). 3. REINFORCING BARS SHALL BE CONTINUOUS AROUND CORNERS 4. NO CONCRETE SHALL BE PLACED ON FROZEN SUBGRADE. 5. ANCHOR BOLTS SHALL BE 1/2 INCH DIAMETER, 12 INCHES LONG, SPACED AT 48 INCH MAXIMUM AND 12 INCHES MAXIMUM FROM CORNERS AND ENDS. 6. VERIFY ALL PLUMBING, MECHANICAL, AND ELECTRICAL REQUIREMENTS BEFORE POURING CONCRETE. 7. PROVIDE 8 INCHES OF FREE-DRAINING COMPACTED GRAVEL AND 10 MIL POLYETHYLENE VAPOR BARRIER UNDER SLABS ON GRADE. 8. PROVIDE CONTROL JOINTS IN SLABS TO CONTROL CRACKING. SAW CUT TO A DEPTH OF 1/4 SLAB THICKNESS (1 INCH MINIMUM). CONTROL JOINTS SHOULD BE SAW CUT AS SOON AS PRACTICAL. STRUCTURAL STEEL 1. STRUCTURAL STEEL WORK SHALL CONFORM TO “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”(AISC 1989), “CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES”(AISC), AND “STRUCTURAL WELDING CODE”(AWS D1.1) 2. STRUCTURAL STEEL SHALL BE DETAILED IN ACCORDANCE WITH “DETAILING FOR STEEL CONSTRUCTION”(AISC). 3. WIDE FLANGE STEEL BEAMS SHALL CONFORM TO ASTM A572 (Fy = 50 KSI). 4. STEEL PIPE SECTIONS SHALL CONFORM TO ASTM A53, TYPE E OR S, GRADE B. HSS STEEL TUBE SHALL CONFORM TO ASTM A500 GRADE B (Fy = 46 KSI) 5. PLATES AND ANGLES SHALL CONFORM TO ASTM A36. 6. HIGH STRENGTH BOLTS SHALL CONFORM TO ASTM A325. MINIMUM DIAMETER SHALL BE 3/4 INCH. 7. WELDS SHALL FULLY DEVELOP THE STRENGTH OF THE MATERIALS BEING WELDED. FILLET WELDS SHALL BE 1/4 INCH MINIMUM. 8. PROVIDE TEMPORARY ERECTION BRACING AS REQUIRED DURING STEEL ERECTION. FRAMING SHALL BE TRUE AND PLUMB BEFORE CONNECTIONS ARE FINALLY BOLTED OR WELDED 9. ALL DIMENSIONS SHALL BE VERIFIED IN THE FIELD PRIOR TO STEEL FABRICATION. 10. STRUCTURAL STEEL AND STEEL JOISTS SHALL BE PAINTED IN THE SHOP WITH ONE COAT OF PRIMER. 11. STEEL SHOP DRAWINGS SHALL BE SUBMITTED FOR REVIEW AND APPROVAL. 12. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY PROPOSED HOLES OR NOTCHES IN ANY STEEL MEMBER. WOOD 1. FRAMING LUMBER SHALL BE SPRUCE-PINE-FIR #2 OR BETTER. 2. ALL POSTS SHALL BE FULLY BLOCKED BETWEEN FLOORS WITH THE GRAIN OF BLOCKING IN A VERTICAL ORIENTATION. 3. PROVIDE AN ADDITIONAL JOIST UNDER ALL INTERIOR WALLS RUNNING PARALLEL TO FLOOR JOISTS. PROVIDE BLOCKING BETWEEN FLOOR JOISTS FOR ALL INTERIOR WALLS RUNNING PERPENDICULAR TO FLOOR JOISTS. 4. PROVIDE BRIDGING AT MID-SPAN OF ALL JOISTS WITHOUT CEILING BELOW. 5. LAMINATED VENEER LUMBER (LVL) SHALL HAVE A MODULUS OF ELASTICITY (E) OF 2,000,000 PSI AND AN ALLOWABLE BENDING STRESS (Fb) OF 3,100 PSI. LVL’S SHALL BE INSTALLED AND FASTENED TOGETHER PER MANUFACTURER’S RECOMMENDATIONS. 6. CONFORM TO MANUFACTURER’S RECOMMENDATIONS WITH RESPECT TO INSTALLATION, CUTTING, NOTCHING, AND FASTENING OF ALL ENGINEERED LUMBER. 7. PROVIDE SIMPSON H2.5 HURRICANE TIES AT EVERY RAFTER/ TOP PLATE CONNECTION. 8. CONNECT OPPOSING RAFTERS TOGETHER WITH COLLAR TIES OR WITH STEEL STRAP TIES OVER THE RIDGE (SIMPSON LSTA24). 9. EXTERIOR WALLS SHALL BE CONSTRUCTED USING THE CS-WSP BRACING METHOD (CONTINUOUSLY SHEATHED WOOD STRUCTURALPANELS) IN ACCORDANCE WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE. SPECIFIC REQUIREMENTS INCLUDE: SHEATHING APPLIED WITH 8d COMMON NAILS SPACED AT 6 INCHES ALONG EDGES AND AT 12 INCHES ELSEWHERE. 10. FOR EXTERIOR BRACED WALLS, HORIZONTAL JOINTS IN THE BRACED WALL PANELS ARE REQUIRED TO BE BLOCKED (2015 IRC SECTION R602.10.10). 11. WHERE RAFTERS ARE SUPPORTED ON BRACED WALLS, BLOCKING IS REQUIRED BETWEEN THE RAFTERS IN ACCORDANCE WITH SECTION R602.10.8.2 OF THE 2015 IRC. 12. EACH DECK IS TO BE LATERALLY TIED TO THE MAIN STRUCTURE IN ACCORDANCE WITH SECTION R507.2.4 OF THE 2015 INTERNATIONAL RESIDENTIAL CODE. 13. DESIGN AND DETAILING OF DECK RAILING IS THE RESPONSIBILITY OF THE CONTRACTOR. REFER TO THE 2015 INTERNATIONAL RESIDENTIAL CODE AND THE PRESCRIPTIVE RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE PUBLISHED BY THE AMERICAN FOREST AND PAPER ASSOCIATION. 1/2" = 1'-0"3 DECK BEAM+RAILING DETAIL 1/2" = 1'-0"5 TYP. SECTION THROUGH PIER 1/2" = 1'-0"4 TYPICAL DECK LEDGER DETAIL 1/2" = 1'-0"2 BUILDING SECTION CONSTRUCTION MANAGER: NI K O ' S R E S I D E N C E SC O P E : P R O P O S E D C H A N G E O F O C C U P A N C Y 56 S c h o o l S t , S a le m , M A 0 1 9 7 0 ADIMIR TOSKA 26 Beaver Park Danvers, MA 01923 Phone # 978-473-0699 PARID & MIKAELA LLC