Loading...
AT&T Rooftop Installation-March 2023Design Review Board Recommendation Small Project Review - SRA-23-2 Address of Project: 27 CHARTER STREET Meeting Date:March 22, 2023 Members Present:Paul Durand, David Jaquith, Glenn Kennedy, Catherine Miller, Marc Perras Members Absent:J. Michael Sullivan, Sarah Tarbet Decision:To approve the project as presented and conditioned herein. Referenced Plans and Documents: - Plan Set titled, "AT&T, Site Number MAL03139, Salem Charter Street", prepared by Centerline Communications, 750 West Center Street, Suite 301, West Bridgewater, MA 02379, dated 2/22/23. Structural Analysis Report, prepared by Hudson Design Group LLC, 45 Beechwood Drive, North Andover, MA 01845, dated 1/20/23. Conditions of Approval: - Consistency with Approved Design/Plans: Should the applicant determine that the project may not be completed as presented and conditioned herein, he/she/they shall return to the DRB to review proposed modifications prior to making any changes in the field. - The applicant shall paint the antenna a brick/mauve color to match the existing exterior façade. Findings: - The Board found that the project is consistent with the design standards for telecommunications projects. The project is modest in scope and will result in a de minimis change to the exterior façade. Signature of the DRB: By the signature below, I certify that this recommendation accurately reflects the actions of the Design Review Board. Paul Durand, Chair Date Signed: March 23, 2023 SRA-23-2 SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETFA CODE: 12574920PACE ID: MRCTB056249, MRCTB056225, MRCTB053466, MRCTB053444PROJECT: 5G NR RADIO, 5G NR 1SR CBAND, 5G NR SOFTWARE RADIO, 5GNR ACTIVATION 2023 UPGRADEPROJECTSITE· · · · · · · · · · · · SHEET NO.DESCRIPTIONREV.72 HOURS PRIORUNDERGROUND SERVICE ALERTWWW.DIGSAFE.COMISSUED FOR PERMITTING SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.GROUNDING NOTESGENERAL NOTES ROOF PLANEQUIPMENT PLANSITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC. SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.EXISTING ANTENNA PLAN SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.PROPOSED ANTENNA PLAN SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.ELEVATION SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.FINAL ANTENNA SCHEDULEPROPOSED LTE ANTENNA MOUNTING DETAILNOTE:PROPOSED DoD + C BAND ANTENNA MOUNTING DETAIL SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.GROUNDING RISER DIAGRAMGROUND BAR - DETAIL (AS REQUIRED)GROUND WIRE TO GROUND BAR CONNECTION DETAILTYPICAL GROUND BAR CONNECTION DETAIL SITE NUMBER: MAL03139SITE NAME: SALEM CHARTER STREETAT&T550 COCHITUATE ROADFRAMINGHAM, MA 0170145 BEECHWOOD DRIVE, NORTH ANDOVER, MA 01845TEL: (978) 557-5553TEP OPCO, LLC.RF PLUMBING DIAGRAMNOTE:NOTE: SCOPE OF WORK: Hudson Design Group LLC (HDG) has been authorized by AT&T to conduct a structural evaluation of the structure supporting the proposed AT&T equipment located in the areas depicted in the latest HDG construction drawings. This report represents this office’s findings, conclusions and recommendations pertaining to the support of AT&T’s proposed equipment. This office conducted an on-site visual survey of the above areas on October 21, 2021. Attendees included Patrick Barrett (HDG – Field Technician). The following documents were used for our reference: · Building Plans prepared by Robert Charles Associates Inc., dated January 8, 1973 · Previous HDG Construction Drawings dated December 9, 2016. · Previous HDG Structural Analysis Report dated March 24, 2020. CONCLUSION SUMMARY: Based on our evaluation, we have determined that the existing structure IS CAPABLE of supporting the proposed equipment loading. Based on our evaluation, we have determined that the existing mounts ARE CAPABLE of supporting the proposed equipment loading. Member Controlling Load Case Stress Ratio Pass/Fail Antenna Mount 2” std. Pipe Bending 93% PASS Equipment Platform 3 LC8 50% PASS Based on our evaluation, we have determined that the existing connections ARE CAPABLE of supporting the proposed equipment loading. Member Stress Ratio Pass/Fail Existing Connection (Antenna Mount) HIT-HY 150 95% PASS Existing Connection (Equipment Platform) HIT-HY 150 11% PASS HDG did not perform a condition assessment of the entire roof but did perform an inspection of the existing roof members and structural bearing walls below the area where the equipment is proposed to be located. APPURTENANCE CONFIGURATION: Appurtenances Dimensions Weight **Elevation Mount (3) 800-10966 Antennas 96.0”x20.0”x6.9” 115 lbs 110’ Wall Mount (3) RRUS-32 B30 RRH’s 27.2”x12.1”x7.0” 60 lbs - Ballast Sled (3) B5/B12 4449 RRH’s 17.9”x13.2”x9.5” 71 lbs - Ballast Sled (3) B2/B66A 8843 RRH’s 14.9”x13.2”x10.9” 72 lbs - Ballast Sled (3) RRUS-E2 B29 RRH’s 20.4”x18.5”x7.5” 53 lbs - Ballast Sled (3) B14 4478 RRH’s 18.1”x13.4”x8.3” 60 lbs - Ballast Sled (6) Squid Surge Arrestors 24.0”x9.7” Ø 33 lbs - Ballast Sled (1) LTE Rack - 1000 lbs - Platform (1) Battery Rack - 2000 lbs - Platform (1) Power Plant - 1000 lbs - Platform (1) FIF Rack - 300 lbs - Platform (3) AIR6419 Antennas 31.0”x16.1”x7.3” 66 lbs 111’-9” Wall Mount (3) AIR6449 Antennas 30.6”x15.9”x10.6” 82 lbs 108’-2” Wall Mount (3) QD8616-7 Antennas 92.0”x22.0”x9.6” 69 lbs 110’ Wall Mount (1) Battery Rack w/ (2) Strings of Batteries - 2000 lbs - Platform * Proposed equipment shown in bold. ** Elevation to antenna centerline. THIS PAGE CONTAINS CONFIDENTIAL, PROPRIETARY OR TRADE SECRET INFORMATION EXEMPT FROM DISCLOSURE UNDER APPLICABLE LAW. DESIGN CRITERIA: International Building Code (IBC) 2015 with Massachusetts State Building Code 9th Edition, and ASCE 7-10 (Minimum Design Loads for Buildings and Other Structures). Wind Reference Wind Speed: 127 mph (780 CMR Table 1604.11) Exposure Category: C (ASCE 7-10 Chapter 26) Risk Category: II (ASCE 7-10 Table 1.5-1) Snow Ground Snow, Pg: 50 (780 CMR Table 1604.11) Importance Factor (Is): 1.0 (ASCE 7-10 Table 1.5-2) Exposure Factor (Ce): 0.9 (Fully Exposed, Table 7-2) Thermal Factor (Ct): 1.0 (ASCE 7-10 Table 7-3) Flat Roof Snow Load: 31.5 psf (ASCE 7-10 Equation 7.3-1) Min. Flat Roof Snow Load: 30 psf EIA/TIA-222-H Structural Standards for Steel Antenna Towers and Antenna Supporting Structures Wind City/Town: Salem County: Essex Wind Load: 127 mph (TIA-222-H Figure B-2) Ice Design Ice Thickness (ti): 1.0 in (TIA-222-H Figure B-9) Structure Class: II (TIA-222-H Table 2-1) Importance Factor (Ii): 1.0 (TIA-222-H Table 2-3) Factored Thickness of Radial Ice (tiz): 1.13 in (TIA-222-H Sec. 2.6.10) EXISTING ROOF CONSTRUCTION: The roof system consists of a roofing membrane over rigid insulation on cast-in-place steel reinforced concrete 2-way slab, supported by reinforced concrete columns. EXISTING PARAPET CONSTRCUTION: The existing parapet consists of a concrete beam. ANTENNA SUPPORT RECOMMENDATIONS: · The proposed Alpha sector antenna is proposed to be mounted on existing pipe masts secured to the existing building façade with angles and epoxy anchors. · The proposed Beta and Gamma sector antennas are proposed to be mounted on existing pipe masts installed on existing mounts secured to the existing building façade with plates and epoxy anchors. Limitations and Assumptions: 1. Reference the latest HDG construction drawings for all the equipment locations and details. 2. All detail requirements will be designed and furnished in the construction drawings. 3. All structural members and their connections are assumed to be in good condition and are free from defects with no deterioration to its member capacities. 4. HDG is not responsible for any modifications completed prior to and hereafter which HDG was not directly involved. 5. All antennas, coax cables and waveguide cables are assumed to be properly installed and supported as per the manufacturer requirements. 6. If field conditions differ from what is assumed in this report, then the engineer of record is to be notified as soon as possible. FIELD PHOTOS: Photo 1: Sample photo illustrating the existing antenna mounts. Photo 2: Sample photo illustrating the existing connections. FIELD PHOTOS: Photo 3: Sample photo illustrating the existing shelter and equipment platform. Wind and Ice Calculations Date: 1/18/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC 2.6.5.2 Velocity Pressure Coeff: Kz= 2.01 (z/zg) 2/α z= 111.75 (ft) zg=900 (ft) Kz=1.291 α= 9.5 Kzmin ≤ Kz ≤ 2.01 Table 2-4 Exposure Zg α Kzmin Kc B 1200 ft 7.0 0.70 0.9 C 900 ft 9.5 0.85 1.0 D 700 ft 11.5 1.03 1.1 2.6.6.2 Topographic Factor: Table 2-5 Topo. Category Kt f 2 0.43 1.25 3 0.53 2.0 4 0.72 1.5 Kzt= [1+(Kc Kt/Kh)]2 Kh= e (f*z/H) Kzt=#DIV/0!Kh=#DIV/0! Kc=1.0 (from Table 2-4) (If Category 1 then K zt =1.0)Kt=0 (from Table 2-5) f=0 (from Table 2-5) Category=1 z=110 zs=20 (Mean elevation of base of structure above sea level) H=0 (Ht. of the crest above surrounding terrain) Kzt=1.00 (from 2.6.6.2.1) Ke=1.00 (from 2.6.8) 2.6.10 Design Ice Thickness Max Ice Thickness =ti = 1.00 in Importance Factor =I=1.0 (from Table 2-3) Kiz =1.13 (from Sec. 2.6.10) tiz= ti*I*Kiz*(Kzt)0.35 tiz = 1.13 in Date: 1/18/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC 2.6.9 Gust Effect Factor 2.6.9.1 Self Supporting Lattice Structures Gh = 1.0 Latticed Structures > 600 ft Gh = 0.85 Latticed Structures 450 ft or less Gh = 0.85 + 0.15 [h/150 - 3.0]h= ht. of structure h= 114 Gh=0.85 2.6.9.2 Guyed Masts Gh=0.85 2.6.9.3 Pole Structures Gh=1.1 2.6.9 Appurtenances Gh=1.0 2.6.9.4 Structures Supported on Other Structures (Cantilivered tubular or latticed spines, pole, structures on buildings (ht. : width ratio > 5) Gh=1.35 Gh= 1.00 2.6.11.2 Design Wind Force on Appurtenances F=qz*Gh*(EPA)A qz= 0.00256*Kz*Kzt*Ks*Ke*Kd*Vmax 2 Kz=1.291 (from 2.6.5.2) Kzt=1.0 (from 2.6.6.2.1) Ks=1.0 (from 2.6.7) qz=51.41 Ke=1.00 (from 2.6.8) qz (ice)=7.85 Kd=0.95 (from Table 2-2) qz (30)=2.82 Vmax=127 mph (Ultimate Wind Speed) Vmax (ice)=50 mph V30=30 mph Table 2-2 Structure Type Wind Direction Probability Factor, Kd Latticed structures with triangular, square or rectangular cross sections 0.85 Tubular pole structures supporting antennas enclosed within a cylindrical shroud 1.00 Tubular pole structures, latticed structures with other cross sections, appurtenances 0.95 Date: 1/18/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC Determine Ca: Table 2-9 Round C < 39 (Subcritical) 39 ≤ C ≤ 78 (Transitional) C > 78 (Supercritical) Ice Thickness =1.13 in Angle =0 (deg)Equivalent Angle =180 (deg) Appurtenances Height Width Depth Flat Area Aspect Ratio Ca Force (lbs)Force (lbs) (w/ Ice) Force (lbs) (30 mph) AIR6419 Antenna 31.0 16.1 7.3 3.47 1.93 1.20 214 40 12 AIR6419 Antenna (Side)31.0 7.3 16.1 1.57 4.25 1.28 103 22 6 AIR6449 Antenna 30.6 15.9 10.6 3.38 1.92 1.20 208 39 11 AIR6449 Antenna (Side)30.6 10.6 15.9 2.25 2.89 1.22 141 28 8 QD8616-7 Antenna 92.0 22.0 9.6 14.06 4.18 1.27 921 159 51 QD8616-7 Antenna (Side)92.0 9.6 22.0 6.13 9.58 1.49 469 90 26 800-10966 Antenna 96.0 20.0 6.9 13.33 4.80 1.30 893 155 49 800-10966 Antenna (Side)96.0 6.9 20.0 4.60 13.91 1.63 386 80 21 RRUS-32 B30 RRH 27.2 12.1 7.0 2.29 2.25 1.20 141 28 8 B5/B12 4449 RRH 17.9 13.2 9.5 1.64 1.36 1.20 101 20 6 B2/B66A 8843 RRH 14.9 13.2 10.9 1.37 1.13 1.20 84 17 5 RRUS-E2 B29 RRH 20.4 18.5 7.5 2.62 1.10 1.20 162 31 9 B14 4478 RRH 18.1 13.4 8.3 1.68 1.35 1.20 104 21 6 Surge Arrestor 24.0 9.7 9.7 1.62 2.47 0.70 58 12 3 Note: Linear interpolation may be used for aspect ratios other than those shown. Flat Aspect Ratio is the overall length/width ratio in the plane normal to the wind direction. (Aspect ratio is independent of the spacing between support points of a linear appurtenance, 1.2 0.7 4.14/(C0.485) 0.5 3.66/(C0.415) 46.8/(C .1.0) 1.4 0.8 0.6 0.6 1.2 Aspect Ratio ≤ 2.5 Aspect Ratio = 7 Aspect Ratio ≥ 25 Force Coefficients (Ca) for Appurtenances Member Type Ca Ca Ca 2.0 Square/Rectangular HSS 1.2 - 2.8(rs) ≥ 0.85 1.4 - 4.0(rs) ≥ 0.90 2.0 - 6.0(rs) ≥ 1.25 Date: 1/20/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC Thickness of ice:1.13 in. Density of ice:56 pcf AIR6419 Antenna AIR6449 Antenna Weight of ice based on total radial SF area: Weight of ice based on total radial SF area: Height (in): 31.0 Height (in): 30.6 Width (in): 16.1 Width (in): 15.9 Depth (in): 7.3 Depth (in): 10.6 Total weight of ice on object: 67 lbs Total weight of ice on object: 71 lbs Weight of object: 66.0 lbs Weight of object: 82.0 lbs Combined weight of ice and object: 133 lbs Combined weight of ice and object: 153 lbs QD8616-7 Antenna 800-10966 Antenna Weight of ice based on total radial SF area: Weight of ice based on total radial SF area: Height (in): 92.0 Height (in): 96.0 Width (in): 22.0 Width (in): 20.0 Depth (in): 9.6 Depth (in): 6.9 Total weight of ice on object: 266 lbs Total weight of ice on object: 246 lbs Weight of object: 69.0 lbs Weight of object: 115.0 lbs Combined weight of ice and object: 335 lbs Combined weight of ice and object: 361 lbs B5/B12 4449 RRH RRUS-32 B30 RRH Weight of ice based on total radial SF area: Weight of ice based on total radial SF area: Height (in): 17.9 Height (in): 27.2 Width (in): 13.2 Width (in): 12.1 Depth (in): 9.5 Depth (in): 7.0 Total weight of ice on object: 36 lbs Total weight of ice on object: 47 lbs Weight of object: 71.0 lbs Weight of object: 60.0 lbs Combined weight of ice and object: 107 lbs Combined weight of ice and object: 107 lbs RRUS-E2 B29 RRH B2/B66A 8843 RRH Weight of ice based on total radial SF area: Weight of ice based on total radial SF area: Height (in): 20.4 Height (in): 14.9 Width (in): 18.5 Width (in): 13.2 Depth (in): 7.5 Depth (in): 10.9 Total weight of ice on object: 50 lbs Total weight of ice on object: 31 lbs Weight of object: 53.0 lbs Weight of object: 72.0 lbs Combined weight of ice and object: 103 lbs Combined weight of ice and object: 103 lbs Squid Surge Arrestor B14 4478 RRH Weight of ice based on total radial SF area: Weight of ice based on total radial SF area: Depth (in): 24.0 Height (in): 18.1 Diameter(in): 9.7 Width (in): 13.4 Total weight of ice on object: 30 lbs Depth (in): 8.3 Weight of object: 33 lbs Total weight of ice on object: 35 lbs Combined weight of ice and object: 63 lbs Weight of object: 60.0 lbs Combined weight of ice and object: 95 lbs ICE WEIGHT CALCULATIONS Antenna Mount Calculations Steel Beam Hudson Design Group LLCLic. # : KW-06013026 DESCRIPTION:Pipe Mast (QD8616-7) Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: MA3139.ec6 Project Title:SALEM CHARTER STREET Engineer:ID Project ID:MA3139 Printed: 18 JAN 2022, 8:46AM Project Descr: CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : ksi Bending Axis :Major Axis Bending Completely Unbraced Allowable Strength Design Fy : Steel Yield :35.0 ksi Beam Bracing :E: Modulus :29,000.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight calculated and added to loading Load(s) for Span Number 2 Point Load : W = 0.4610 k @ 0.50 ft, (QD8616-7 Antenna Load) Load(s) for Span Number 3 Point Load : W = 0.4610 k @ 4.0 ft, (AIR6419 Antenna Load) .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.925 : 1 Load Combination +D+0.60W Span # where maximum occurs Span # 2 Location of maximum on span 1.500 ft 0.8618 k Mn / Omega : Allowable 1.245 k-ft Vn/Omega : Allowable Pipe2 StdSection used for this span Span # where maximum occurs Location of maximum on span Span # 2 Load Combination +D+0.60W 6.287 k Section used for this span Pipe2 Std Ma : Applied Maximum Shear Stress Ratio =0.137 : 1 1.500 ft 1.152 k-ft Va : Applied 781 >= 114 Ratio =1245 >= Maximum Deflection Max Downward Transient Deflection 1.693 in 70Ratio =>= Max Upward Transient Deflection -0.023 in Ratio = Max Downward Total Deflection 1.054 in Ratio =>= Max Upward Total Deflection -0.014 in .Maximum Forces & Stresses for Load Combinations Span # Summary of Moment ValuesLoad Combination Summary of Shear ValuesMax Stress Ratios M V Mmax -Mmax +Rm VnxMa Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length D Only Dsgn. L = 1.00 ft 1 0.001 0.004 -0.00 0.00 2.08 1.25 1.00 1.00 0.03 10.50 6.29 Dsgn. L = 1.50 ft 2 0.037 0.005 -0.00 -0.05 0.05 2.08 1.25 1.67 1.00 0.03 10.50 6.29 Dsgn. L = 5.00 ft 3 0.037 0.003 -0.05 0.05 2.08 1.25 1.00 1.00 0.02 10.50 6.29 +D+0.60W Dsgn. L = 1.00 ft 1 0.001 0.092 -0.00 0.00 2.08 1.25 1.00 1.00 0.58 10.50 6.29 Dsgn. L = 1.50 ft 2 0.925 0.137 -0.00 -1.15 1.15 2.08 1.25 1.79 1.00 0.86 10.50 6.29 Dsgn. L = 5.00 ft 3 0.925 0.047 -1.15 1.15 2.08 1.25 1.00 1.00 0.29 10.50 6.29 +D+0.450W Dsgn. L = 1.00 ft 1 0.001 0.070 -0.00 0.00 2.08 1.25 1.00 1.00 0.44 10.50 6.29 Dsgn. L = 1.50 ft 2 0.703 0.104 -0.00 -0.88 0.88 2.08 1.25 1.79 1.00 0.65 10.50 6.29 Dsgn. L = 5.00 ft 3 0.703 0.036 -0.88 0.88 2.08 1.25 1.00 1.00 0.23 10.50 6.29 +0.60D+0.60W Dsgn. L = 1.00 ft 1 0.001 0.091 -0.00 0.00 2.08 1.25 1.00 1.00 0.57 10.50 6.29 Dsgn. L = 1.50 ft 2 0.911 0.135 -0.00 -1.13 1.13 2.08 1.25 1.79 1.00 0.85 10.50 6.29 Dsgn. L = 5.00 ft 3 0.911 0.046 -1.13 1.13 2.08 1.25 1.00 1.00 0.29 10.50 6.29 +0.60D Dsgn. L = 1.00 ft 1 0.001 0.003 -0.00 0.00 2.08 1.25 1.00 1.00 0.02 10.50 6.29 Dsgn. L = 1.50 ft 2 0.022 0.003 -0.00 -0.03 0.03 2.08 1.25 1.67 1.00 0.02 10.50 6.29 Steel Beam Hudson Design Group LLCLic. # : KW-06013026 DESCRIPTION:Pipe Mast (QD8616-7) Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: MA3139.ec6 Project Title:SALEM CHARTER STREET Engineer:ID Project ID:MA3139 Printed: 18 JAN 2022, 8:46AM Project Descr: Span # Summary of Moment ValuesLoad Combination Summary of Shear ValuesMax Stress Ratios M V Mmax -Mmax +Rm VnxMa Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Dsgn. L = 5.00 ft 3 0.022 0.002 -0.03 0.03 2.08 1.25 1.00 1.00 0.01 10.50 6.29 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 0.0377 0.000 0.0000 0.000 W Only20.0000 0.000 -0.0230 0.890 W Only 3 1.6930 5.000 0.0000 0.890 . Load Combination Support 1 Support 2 Support 3 Support 4 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum 1.844-0.922 Overall MINimum 0.030-0.014 D Only 0.050-0.023 +D+0.60W 1.157-0.576 +D+0.450W 0.880-0.438 +0.60D+0.60W 1.137-0.567 +0.60D 0.030-0.014 W Only 1.844-0.922 Steel Beam Hudson Design Group LLCLic. # : KW-06013026 DESCRIPTION:Pipe Mast (AIR6449 + AIR6419) Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: MA3139.ec6 Project Title:SALEM CHARTER STREET Engineer:ID Project ID:MA3139 Printed: 18 JAN 2022, 8:46AM Project Descr: CODE REFERENCES Calculations per AISC 360-10, IBC 2015, CBC 2016, ASCE 7-10 Load Combination Set : ASCE 7-10 Material Properties Analysis Method : ksi Bending Axis :Major Axis Bending Completely Unbraced Allowable Strength Design Fy : Steel Yield :35.0 ksi Beam Bracing :E: Modulus :29,000.0 .Service loads entered. Load Factors will be applied for calculations.Applied Loads Beam self weight calculated and added to loading Load(s) for Span Number 2 Point Load : W = 0.1070 k @ 0.50 ft, (AIR6419 Antenna Load) Load(s) for Span Number 3 Point Load : W = 0.1070 k @ 1.0 ft, (AIR6419 Antenna Load) Point Load : W = 0.1050 k @ 2.0 ft, (AIR6419 Antenna Load) Point Load : W = 0.1050 k @ 4.0 ft, (AIR6419 Antenna Load) .Design OKDESIGN SUMMARY Maximum Bending Stress Ratio =0.392 : 1 Load Combination +D+0.60W Span # where maximum occurs Span # 2 Location of maximum on span 1.500 ft 0.3482 k Mn / Omega : Allowable 1.245 k-ft Vn/Omega : Allowable Pipe2 StdSection used for this span Span # where maximum occurs Location of maximum on span Span # 2 Load Combination +D+0.60W 6.287 k Section used for this span Pipe2 Std Ma : Applied Maximum Shear Stress Ratio =0.055 : 1 1.500 ft 0.488 k-ft Va : Applied 1,871 >= 316 Ratio =2810 >= Maximum Deflection Max Downward Transient Deflection 0.571 in 210Ratio =>= Max Upward Transient Deflection -0.010 in Ratio = Max Downward Total Deflection 0.380 in Ratio =>= Max Upward Total Deflection -0.006 in .Maximum Forces & Stresses for Load Combinations Span # Summary of Moment ValuesLoad Combination Summary of Shear ValuesMax Stress Ratios M V Mmax -Mmax +Rm VnxMa Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length D Only Dsgn. L = 1.00 ft 1 0.001 0.004 -0.00 0.00 2.08 1.25 1.00 1.00 0.03 10.50 6.29 Dsgn. L = 1.50 ft 2 0.037 0.005 -0.00 -0.05 0.05 2.08 1.25 1.67 1.00 0.03 10.50 6.29 Dsgn. L = 5.00 ft 3 0.037 0.003 -0.05 0.05 2.08 1.25 1.00 1.00 0.02 10.50 6.29 +D+0.60W Dsgn. L = 1.00 ft 1 0.001 0.044 -0.00 0.00 2.08 1.25 1.00 1.00 0.28 10.50 6.29 Dsgn. L = 1.50 ft 2 0.392 0.055 -0.00 -0.49 0.49 2.08 1.25 1.73 1.00 0.35 10.50 6.29 Dsgn. L = 5.00 ft 3 0.392 0.033 -0.49 0.49 2.08 1.25 1.00 1.00 0.21 10.50 6.29 +D+0.450W Dsgn. L = 1.00 ft 1 0.001 0.034 -0.00 0.00 2.08 1.25 1.00 1.00 0.22 10.50 6.29 Dsgn. L = 1.50 ft 2 0.303 0.043 -0.00 -0.38 0.38 2.08 1.25 1.73 1.00 0.27 10.50 6.29 Dsgn. L = 5.00 ft 3 0.303 0.026 -0.38 0.38 2.08 1.25 1.00 1.00 0.16 10.50 6.29 +0.60D+0.60W Steel Beam Hudson Design Group LLCLic. # : KW-06013026 DESCRIPTION:Pipe Mast (AIR6449 + AIR6419) Software copyright ENERCALC, INC. 1983-2020, Build:12.20.8.24 File: MA3139.ec6 Project Title:SALEM CHARTER STREET Engineer:ID Project ID:MA3139 Printed: 18 JAN 2022, 8:46AM Project Descr: Span # Summary of Moment ValuesLoad Combination Summary of Shear ValuesMax Stress Ratios M V Mmax -Mmax +Rm VnxMa Max Mnx/Omega Cb Va MaxMnx Vnx/OmegaSegment Length Dsgn. L = 1.00 ft 1 0.001 0.043 -0.00 0.00 2.08 1.25 1.00 1.00 0.27 10.50 6.29 Dsgn. L = 1.50 ft 2 0.377 0.053 -0.00 -0.47 0.47 2.08 1.25 1.73 1.00 0.34 10.50 6.29 Dsgn. L = 5.00 ft 3 0.377 0.032 -0.47 0.47 2.08 1.25 1.00 1.00 0.20 10.50 6.29 +0.60D Dsgn. L = 1.00 ft 1 0.001 0.003 -0.00 0.00 2.08 1.25 1.00 1.00 0.02 10.50 6.29 Dsgn. L = 1.50 ft 2 0.022 0.003 -0.00 -0.03 0.03 2.08 1.25 1.67 1.00 0.02 10.50 6.29 Dsgn. L = 5.00 ft 3 0.022 0.002 -0.03 0.03 2.08 1.25 1.00 1.00 0.01 10.50 6.29 . Location in SpanLoad CombinationMax. "-" Defl Location in SpanLoad Combination Span Max. "+" Defl Overall Maximum Deflections W Only 1 0.0161 0.000 0.0000 0.000 W Only20.0000 0.000 -0.0096 0.880 W Only 3 0.5706 5.000 0.0000 0.880 . Load Combination Support 1 Support 2 Support 3 Support 4 Vertical Reactions Support notation : Far left is #1 Values in KIPS Overall MAXimum 0.844-0.420 Overall MINimum 0.030-0.014 D Only 0.050-0.023 +D+0.60W 0.557-0.275 +D+0.450W 0.430-0.212 +0.60D+0.60W 0.537-0.266 +0.60D 0.030-0.014 W Only 0.844-0.420 Date: 10/8/2019 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC CHECK EPOXY ANCHOR CONNECTION CAPACITY → EXISTING ANCHORS → ANTENNA MOUNT Reference:Hilti North American Product Technical Guide, 2008 Epoxy Type =HIT-HY150 Anchor Diameter =5/8 in.(HAS-E Threaded Rod) Embedment Depth = 3-3/8 in. f'c of Concrete = 2000 psi Allowable Loads (lbs) Tensile Load 1620 Shear Load 2460 TENSILE FORCES Reaction F =1844 lbs.(See ENERCALC Output) SHEAR FORCES Wind Load 1844 lbs.(See ENERCALC Output) Dead and Ice Load 266 lbs.(See ENERCALC Output) Resultant:1863 lbs. No. of Supports =1 No. of Anchors / Support =2 Tension Design Load / Anchor = ft=922.00 lbs.<1620 lbs.Therefore, OK ! Shear Design Load / Anchor= fv=931.54 lbs.<2460 lbs.Therefore, OK ! CHECK COMBINED TENSION AND SHEAR ft / FT +fv / FV ≤1.0 0.569 + 0.379 =0.948 <1.0 Therefore, OK ! Spacing Reduct. Factor 1 1 Edge Reduct. Factor 1 1 Reduced Loads (lbs) 1620 2460 Conc. Thickness Reduct. Factor 1 1 Equipment Platform Calculations Date: 1/20/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC Wind Analysis → Equipment Cabinets Reference Codes: -Massachusetts State Building Code, 9th Ed. -International Building Code 2015 (IBC 2015) -Minimum Design Loads for Buildings and Other Structures (ASCE 7-10) Structure Classification II (ASCE 7-10 Table 1.5-1) Basic Wind Speed, V 127 mph (780 CMR Table 1604.11) Importance Factor, I 1 (ASCE 7-10 Table 1.5-2) Exposure Category B (ASCE 7-10 Section 26.7) Height Above Ground Level, z 120 ft (Center of Enclosure) Exposure Coefficient, K z 1.04 (ASCE 7-10 Table 29-3.1) Wind Directionality Coef., Kd 0.90 (ASCE 7-10 Table 26.6-1) Topographic Factor, Kzt 1.00 (ASCE 7-10 Section 26.8.2) Velocity Pressure, qz =0.00256KzKztKdV2 (ASCE 7-10 Equation 29.3-1) =38.65 psf Gust Factor, G 0.85 (ASCE 7-10 Section 26.9) Enclosure Shape: Square Net Force Coefficient, C f 1.30 (ASCE 7-10 Figure 29.5-1) Area Wind Force, F =qzGCf (ASCE 7-10 Equation 29.5-2) =42.64 psf A B C D E F G H I J K L M Date: 1/20/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC Load Breakdown: Live Loads: Service Load 25 psf Snow Load 30 psf Dead Loads: Grating 15 psf Shelter 17000 lbs (11'-5" x 16'-0") LTE Rack 1000 lbs Battery Rack 2000 lbs Power Plant 1000 lbs FIF Rack 300 lbs Battery Rack 2000 lbs Total 23300 lbs Area Load 128 psf Handrail 10 plf Date: 1/20/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC ●Beam A Dead Load → Handrail 10 plf ●Beam C,D Live Load → Service 25 psf x 1.85 ft. (Tributary Width) =46.3 plf → Service 25 psf x 5.71 ft. (Tributary Width) =142.7 plf → Snow 30 psf x 1.85 ft. (Tributary Width) =55.5 plf → Snow 30 psf x 5.71 ft. (Tributary Width) =171.3 plf Dead Load → Grating 15 psf x 1.85 ft. (Tributary Width) 27.8 plf → Shelter 128 psf x 5.71 ft. (Tributary Width) 727.9 plf → Handrail 10 plf ●Beam E,G Live Load → Service 25 psf x 4.00 ft. (Tributary Width) =100.0 plf Dead Load → Grating 15 psf x 4.00 ft. (Tributary Width) 60.0 plf Date: 1/20/2022 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC Load Breakdown: ●Beam H,I,J,K,L,M Live Load → Service 25 psf x 4.30 ft. (Tributary Width) =107.5 plf Dead Load → Grating 15 psf x 4.30 ft. (Tributary Width) 64.5 plf Current Date: 1/20/2022 8:58 AM Units system: English Current Date: 1/20/2022 9:01 AM Units system: English Current Date: 1/20/2022 8:59 AM Units system: English Current Date: 1/20/2022 8:59 AM Units system: English Current Date: 1/20/2022 3:37 PM Units system: English Load data ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ GLOSSARY Comb : Indicates if load condition is a load combination Load Conditions ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Condition Description Comb.Category ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- DL Dead Load No DL LL Live Load No LL SL Snow Load No SNOW WL1 Wind Load Side 1 No WIND WL2 Wind Load Side 2 No WIND WL3 Wind Load Side 3 No WIND WL4 Wind Load Side 4 No WIND ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Distributed force on members ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Condition Member Dir1 Val1 Val2 Dist1 %Dist2 % [Kip/ft][Kip/ft][ft][ft] ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ DL 1 y -0.728 -0.728 3.00 No 19.00 No y -0.028 -0.028 1.00 No 3.00 No y -0.028 -0.028 19.00 No 22.6667 No y -0.01 -0.01 1.00 No 3.00 No y -0.01 -0.01 19.00 No 22.6667 No 2 y -0.728 -0.728 3.00 No 19.00 No y -0.028 -0.028 1.00 No 3.00 No y -0.028 -0.028 19.00 No 22.6667 No y -0.01 -0.01 1.00 No 3.00 No y -0.01 -0.01 19.00 No 22.6667 No 3 y -0.01 -0.01 4.30 No 15.7167 No 5 y -0.01 0.00 0.00 No 0.00 No 6 y -0.028 0.00 0.00 No 0.00 No y -0.01 0.00 0.00 No 0.00 No 7 y -0.028 0.00 0.00 No 0.00 No y -0.01 0.00 0.00 No 0.00 No 12 y -0.065 0.00 0.00 No 0.00 No 13 y -0.065 0.00 0.00 No 0.00 No 14 y -0.065 0.00 0.00 No 0.00 No 15 y -0.065 0.00 0.00 No 0.00 No 20 y -0.065 0.00 0.00 No 0.00 No 21 y -0.065 0.00 0.00 No 0.00 No LL 1 y -0.143 -0.143 3.00 No 19.00 No Page1 y -0.047 -0.047 1.00 No 3.00 No y -0.047 -0.047 19.00 No 22.6667 No 2 y -0.143 -0.143 3.00 No 19.00 No y -0.047 -0.047 1.00 No 3.00 No y -0.047 -0.047 19.00 No 22.6667 No 6 y -0.047 0.00 0.00 No 0.00 No 7 y -0.047 0.00 0.00 No 0.00 No 12 y -0.108 0.00 0.00 No 0.00 No 13 y -0.108 0.00 0.00 No 0.00 No 14 y -0.108 0.00 0.00 No 0.00 No 15 y -0.108 0.00 0.00 No 0.00 No 20 y -0.108 0.00 0.00 No 0.00 No 21 y -0.108 0.00 0.00 No 0.00 No SL 1 y -0.172 -0.172 3.00 No 19.00 No 2 y -0.172 -0.172 3.00 No 19.00 No ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Load on shells ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Condition Shell Pressure Temp. [Kip/ft2][F] ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- WL1 1 0.043 0.00 WL2 4 0.043 0.00 WL3 3 0.043 0.00 WL4 2 0.043 0.00 ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Self weight multipliers for load conditions ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Self weight multiplier Condition Description Comb.MultX MultY MultZ ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ DL Dead Load No 0.00 -1.00 0.00 LL Live Load No 0.00 0.00 0.00 SL Snow Load No 0.00 0.00 0.00 WL1 Wind Load Side 1 No 0.00 0.00 0.00 WL2 Wind Load Side 2 No 0.00 0.00 0.00 WL3 Wind Load Side 3 No 0.00 0.00 0.00 WL4 Wind Load Side 4 No 0.00 0.00 0.00 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Earthquake (Dynamic analysis only) ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Condition a/g Ang.Damp. [Deg][%] -------------------------------------------------------------------------------------------------------------------------------------------------------- DL 0.00 0.00 0.00 LL 0.00 0.00 0.00 SL 0.00 0.00 0.00 WL1 0.00 0.00 0.00 WL2 0.00 0.00 0.00 WL3 0.00 0.00 0.00 Page2 WL4 0.00 0.00 0.00 -------------------------------------------------------------------------------------------------------------------------------------------------------- Page3 Current Date: 1/20/2022 3:36 PM Units system: English Steel Code Check ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Report: Summary - Group by member Load conditions to be included in design : LC1=1.4DL LC2=1.2DL+1.6LL+0.5SL LC3=1.2DL+LL+1.6SL LC4=1.2DL+1.6SL+0.5WL1 LC5=1.2DL+1.6SL+0.5WL2 LC6=1.2DL+1.6SL+0.5WL3 LC7=1.2DL+1.6SL+0.5WL4 LC8=1.2DL+LL+0.5SL+WL1 LC9=1.2DL+LL+0.5SL+WL2 LC10=1.2DL+LL+0.5SL+WL3 LC11=1.2DL+LL+0.5SL+WL4 LC12=1.2DL+LL+0.2SL LC13=0.9DL+WL1 LC14=0.9DL+WL2 LC15=0.9DL+WL3 LC16=0.9DL+WL4 LC17=0.9DL ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Description Section Member Ctrl Eq.Ratio Status Reference ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ T2L 4X4X3_8 10 LC9 at 50.00%0.20 With warnings Eq. H2-1 11 LC9 at 50.00%0.19 With warnings Eq. H2-1 ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ W 10X19 5 LC9 at 25.00%0.13 OK Eq. H1-1b 6 LC8 at 0.00%0.11 OK Eq. H1-1b 7 LC8 at 0.00%0.10 OK Eq. H1-1b 8 LC10 at 100.00%0.08 OK Eq. H1-1b 19 LC8 at 50.00%0.07 OK Eq. H1-1b ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ W 14X30 3 LC8 at 0.00%0.48 OK Eq. H1-1b 4 LC10 at 0.00%0.50 OK Eq. H1-1b 9 LC11 at 0.00%0.03 OK Eq. H1-1b ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ W 14X43 1 LC9 at 84.38%0.28 OK Eq. H1-1b 2 LC11 at 84.38%0.28 OK Eq. H1-1b ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ W 8X10 12 LC11 at 0.00%0.12 OK Eq. H1-1b 13 LC9 at 0.00%0.12 OK Eq. H1-1b 14 LC9 at 0.00%0.12 OK Eq. H1-1b 15 LC16 at 0.00%0.12 OK Eq. H1-1b 20 LC9 at 0.00%0.18 OK Eq. H1-1b 21 LC11 at 0.00%0.18 OK Eq. H1-1b ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ Page1 Current Date: 1/20/2022 9:02 AM Units system: English Current Date: 1/20/2022 3:37 PM Units system: English Analysis result Envelope for nodal reactions ____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ Note.-lc is the controlling load condition Direction of positive forces and moments Envelope of nodal reactions for : LC1=1.4DL LC2=1.2DL+1.6LL+0.5SL LC3=1.2DL+LL+1.6SL LC4=1.2DL+1.6SL+0.5WL1 LC5=1.2DL+1.6SL+0.5WL2 LC6=1.2DL+1.6SL+0.5WL3 LC7=1.2DL+1.6SL+0.5WL4 LC8=1.2DL+LL+0.5SL+WL1 LC9=1.2DL+LL+0.5SL+WL2 LC10=1.2DL+LL+0.5SL+WL3 LC11=1.2DL+LL+0.5SL+WL4 LC12=1.2DL+LL+0.2SL LC13=0.9DL+WL1 LC14=0.9DL+WL2 LC15=0.9DL+WL3 LC16=0.9DL+WL4 LC17=0.9DL Forces Moments Node Fx lc Fy lc Fz lc Mx lc My lc Mz lc [Kip][Kip][Kip][Kip*ft][Kip*ft][Kip*ft] -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 5 Max 1.968 LC9 12.796 LC3 1.345 LC8 -0.00388 LC16 2.72021 LC15 43.66924 LC3 Min -1.744 LC16 5.408 LC16 -1.126 LC15 -0.01007 LC9 -3.09893 LC8 19.67610 LC16 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 6 Max 1.691 LC9 13.438 LC3 1.158 LC13 0.01073 LC3 3.14545 LC10 44.78805 LC3 Min -1.537 LC16 5.948 LC16 -1.370 LC10 0.00425 LC16 -2.75248 LC13 20.59327 LC16 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 7 Max 1.734 LC14 12.801 LC3 1.319 LC8 -0.00392 LC14 3.05149 LC8 -19.68324 LC14 Min -1.952 LC11 5.411 LC14 -1.123 LC15 -0.01008 LC3 -2.70780 LC15 -43.68112 LC3 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 8 Max 1.523 LC14 13.433 LC3 1.149 LC13 0.01073 LC3 2.72827 LC13 -20.58955 LC14 Min -1.683 LC11 5.945 LC14 -1.352 LC10 0.00428 LC14 -3.11560 LC10 -44.77640 LC3 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Page1 Date: 10/8/2019 Project Name: SALEM CHARTER STREET Project No.: MA3139 Designed By: ID Checked By: MSC CHECK EPOXY ANCHOR CONNECTION CAPACITY → EXISTING ANCHORS → EQUIPMENT PLATFORM Reference:Hilti North American Product Technical Guide, 2008 Epoxy Type =HIT-HY150 Anchor Diameter =3/4 in.(HAS-E Threaded Rod) Embedment Depth = 3-3/8 in. f'c of Concrete = 2000 psi Allowable Loads (lbs) Tensile Load 2365 Shear Load 5435 TENSILE FORCES Reaction F =0 lbs.(Gravity loads to be supported by existing building columns) SHEAR FORCES Reactions in X direction:1968 lbs.(See Bentley Output) Reactions in Z direction:1345 lbs.(See Bentley Output) Resultant:2384 lbs. No. of Supports =1 No. of Anchors / Support =4 Tension Design Load / Anchor = ft=0.00 lbs.<2365 lbs.Therefore, OK ! Shear Design Load / Anchor= fv=595.93 lbs.<5435 lbs.Therefore, OK ! CHECK COMBINED TENSION AND SHEAR ft / FT +fv / FV ≤1.0 0.000 + 0.110 =0.110 <1.0 Therefore, OK ! Spacing Reduct. Factor 1 1 Edge Reduct. Factor 1 1 Reduced Loads (lbs) 2365 5435 Conc. Thickness Reduct. Factor 1 1