Mini Split InstallationDecision Small Project Review - SRA-22-7 Address of Project: 28 FEDERAL STREET Meeting Date:June 8, 2022 Members Present:Grace Napolitano, Chair, David Guarino, Christine Madore, Cynthia Nina-Soto, Dean Rubin Members Absent:None Decision:To approve the project as presented and conditioned herein. Referenced Plans and Documents: - Application documents prepared by Charles Anzalone submitted on April 27, 2022. New Salem Condominium II Association Conditions for Removing Old AC Units and Installing New Mini-Split Units, submitted by Charles Anzalone, dated May 19, 2022. A series of notated photographs showing the property from several different vantage points, submitted by Charles Anzalone, submitted on April 27, 2022. Specification sheets for a Mitsubishi Electric Wall-Mounted Heat Pump System, a Mitsubishi Electric Multi-Zone Inverter Heat-Pump System, and for a Mitsubishi Electric Wall-Mounted Air-Conditioning System. Conditions of Approval: - Validity of Approval: This approval is valid for two years from the date of the meeting. The approval shall no longer be valid if a substantial use and/or construction has not commenced except for good cause within this two-year period. - Consistency with Approved Design/Plans: Should the applicant determine that the project may not be completed as presented and conditioned herein, he/she/they shall return to the SRA to review proposed modifications prior to making any changes in the field. - Screening Maintenance: The existing screen elements, including existing shrubbery, vegetation, and fencing, shall be maintained so that they sufficiently screen the units. If any of the screening elements are removed, whether by design, by accident, or by weather, the elements must be replaced as soon as possible, taking into consideration weather and seasonality concerns. Color of Ground Units: The applicant shall explore an alternate color for the ground units. The bright white can be strident, even with the existing screening elements. If the units are available in a more muted tone or if they can be painted, the applicant shall take the necessary steps to install units with a muted white tone. Compliance with Condominium Association Conditions: The installation of all ductless units shall adhere to the conditions listed in the New Salem Condominium II Association Conditions for Removing Old AC Units and Installing New Mini-Split Units, as voted and approved on May 19, 2022. These conditions shall apply not only to new units, but shall be retroactive and apply to units installed prior to the date of the Authority's final decision. SRA Pre-Approval: If the owners, existing or future, of units A-1, A-2, A-3, A-4, B-1, and C-1 at 28 Federal Street would like to install ductless mini split air conditioner systems, they shall abide by all the conditions listed in this decision document, including those listed in the New Salem Condominium II Association 'Conditions for Removing Old AC Units and Installing New Mini-Split Units' dated May 19, 2022. If the owners of the listed units are not able to adhere to all the required conditions the owners shall apply to the Salem Redevelopment Authority for a Small Project Review of the proposed installation(s). Findings: - The Authority finds that these mini-split units will likely grow in popularity and their installation must be carefully considered to ensure minimal negative visual impact of the infrastructure. Members also found that the New Salem Condominium II Association has carefully considered the design of the installation as evidenced by the Association's conditions. It is because of the care and attention to detail in these conditions, and when coupled with the additional conditions issued by this body, that members are in support of issuing a pre-approval for future mini-split installations at this property. The Authority finds that the infrastructure, when installed pursuant to the conditions in this decision, will result in the infrastructure blending with the building façade and even referencing the right angles and layouts of the buildings' windows. Signature of the SRA: By the signature below, I certify that this recommendation accurately reflects the actions of the Salem Redevelopment Authority Board. Date Signed: June 9, 2022 SRA-22-7 Tom Daniel, AICP, Executive Director Design Review Board Recommendation Small Project Review - SRA-22-7 Address of Project: 28 FEDERAL STREET Meeting Date:May 25, 2022 Members Present:Paul Durand, David Jaquith, Catherine Miller, Marc Perras, Helen Sides, J. Michael Sullivan Members Absent:Glenn Kennedy Decision:To recommend approval as presented and conditioned herein. Referenced Plans and Documents: - Application documents prepared by Charles Anzalone submitted on April 27, 2022. New Salem Condominium II Association Conditions for Removing Old AC Units and Installing New Mini-Split Units, submitted by Charles Anzalone, dated May 19, 2022. A series of notated photographs showing the property from several different vantage points, submitted by Charles Anzalone, submitted on April 27, 2022. Specification sheets for a Mitsubishi Electric Wall-Mounted Heat Pump System, a Mitsubishi Electric Multi-Zone Inverter Heat-Pump System, and for a Mitsubishi Electric Wall-Mounted Air-Conditioning System. Conditions of Approval: - Consistency with Approved Design/Plans: Should the applicant determine that the project may not be completed as presented and conditioned herein, he/she/they shall return to the DRB to review proposed modifications prior to making any changes in the field. - Screening Maintenance: The existing screen elements, including existing shrubbery, vegetation, and fencing, shall be maintained so that they sufficiently screen the units. If any of the screening elements are removed, whether by design, by accident, or by weather, the elements must be replaced as soon as possible, taking into consideration weather and seasonality concerns. Color of Ground Units: The applicant shall explore an alternate color for the ground units. The bright white can be strident, even with the existing screening elements. If the units are available in a more muted tone or if they can be painted, the applicant shall take the necessary steps to install units with a muted white tone. Compliance with Condominium Association Conditions: The installation of all ductless units shall adhere to the conditions listed in the New Salem Condominium II Association Conditions for Removing Old AC Units and Installing New Mini-Split Units, as voted and approved on May 19, 2022. These conditions shall apply not only to new units, but shall be retroactive and apply to units installed prior to the date of the Authority's final decision. Findings: - The Board found that the conditions proposed and approved by the condo association board were comprehensive and, when followed, will ensure that installation of these units will be thoughtful with little visual impact. The conditions focused on the design of the installation will result in the infrastructure blending with the building façade and even referencing the right angles and layouts of the buildings' windows.SRA-22-7 Signature of the DRB: By the signature below, I certify that this recommendation accurately reflects the actions of the Design Review Board. Paul Durand, Chair Date Signed: May 26, 2022 04/27/2022 City of Salem, MA SRA-22-7 SRA-Urban Renewal Area - Small Project Review Additional Applicant Info Project Information Status: Active Date Created: Apr 27, 2022 Applicant Charles Anzalone salemchuck@yahoo.com 28C Federal Street Unit 4 Salem, MA 01970 5084877258 Location 28 FEDERAL STREET Unit U30-4 Unit U30-4 SALEM, MA 01970 Owner: New Salem Condominium II 28 FEDERAL STREET U30-4 SALEM, MA 01970 Is the owner the applicant?  Who is the point of contact for this application? Charles Anzalone Project Name/Title Mini-split A/C Project Description Installation of ductless A/C unit Existing Structure's Square Footage 1,498 Proposed Structure's Square Footage 1,498 Estimated time schedule for completing project 3 days Does your project propose a change to the building's facade?  Signature DRB Recommendation SRA Decision Entry Section The City of Salem encourages the inclusion of Public Art in project proposals. Public Art proposals must be presented to the Public Art Commission for consideration as part of this application's formal approval process. Public Art is loosely defined as any artistic installation on the grounds or exterior spaces of the property. Will your project include a proposal for Public Art? No Do you have a plan in place for Public Art at this location? No If you would like assistance or suggestion for developing public art for this location please contact Julie Barry, Senior Planner of Arts and Culture Planning Email Julie (mailto:jbarry@salem.com? Subject=Contact regarding Public Art) Digital Signature Charles Anzalone 04/21/2022 Conditions of Approval Findings: Conditions of Approval Findings: LETTER OF REQUEST Date: April 27, 2022 To: Salem Redevelopment Authority From: New Salem Condominiums II 28 Federal Street, Salem MA By: Charles Anzalone, Board Member and Clerk 28 Federal Street, Unit C4 This letter is a request to Salem Redevelopment Authority to be placed on their May 25th meeting agenda for the purpose of review and approval of the below outlined proposal. The Board of New Salem Condominiums II has approved this request. STATEMENT OF PROPOSAL The purpose of this request is for approval the placement of exterior conduit on the building and the location of exterior AC units as part of the installation of mini-split air conditioners. This includes conduit previously installed, conduit partially installed and now on-hold and future installations. BACKGROUND The new Salem Condominium II owner’s association had previously approved 2 owners to install AC units under the condition that they complied with conditions of installation prepared by the Board’s building committee. (See attached copy.) These were lower units that are largely screened from view by a 6.5 foot high fence on the Federal Street or South side of the building and 6 foot high hedges on the North side. (See North and South elevations on the drawing.) The next requests from owners were from 3 upper unit installations. A new owner, who did not fully understand our multi-layer approval process by the Board, ie, a vote of approval by all owners, started the installation before that was completed. The Board immediately stopped the installation on the day it was started and until the owner received formal Association approval. When working on that an owner cautioned that SRA approval might be required due to visibility. We then reached out to Kate Newhall-Smith who confirmed that SRA review and approval was necessary. We then retained the services of an architect for design input and the preparation of the submitted drawing. GOING FORWARD The conduit installed on the upper unit, noted on the drawing as B3, will be modified to comply with a configuration as shown on the architect’s drawings. All conduit will be painted to match the color of the clapboards. The drawing also locates those condo units under discussion. It is also our request that the SRA approve the layouts shown would apply for future owners, should they decide to install similar air conditioners. Respectfully, New Salem Condominiums II Charles Anzalone Board Member and Clerk Adrian Vasile 28B Federal Street, Unit B1 Salem, MA 01970 New Salem Condominium II (NCSII) Late Fee Generated February 2021 Original Total: $50.00 to be collected Date: July 21, 2021 URGENT: PLEASE RECTIFY THIS MATTER IMMEDIATELY Dear Adrian Vasile, Despite our previous reminder, the NSCII late fee remains unpaid. As such, we would appreciate you making this payment as soon as possible. The delay of payment causes a negative impact on the NSCII volunteer staff trying to reconcile financial books. DUE AMOUNT: $45.00 PLEASE REMIT PAYMENT TO: New Salem Condominium II We regret to advise that unless payment is received by August 15, 2021 this collection will be passed over to our debt collection agency/lawyer. Any additional fees inquired will be passed on to yourself. You have the right to dispute this debt by submitting written notice within thirty (30) days of receiving this letter. If this letter is not disputed within the thirty (30) day time-frame then the collection will be considered accepted by the debtor. Sincerely, Board of Managers, New Salem Condominium II New Salem Condominium II (NCSII) 28 Federal Street, Salem, Massachusetts 01970 Page 1 of 3 • There are 12 floor-through units each 2 floors. • 6 Upper units and 6 lower units • The Upper units are floors 2 + 3 of the entrance side The Upper units on the Federal St side have a balcony on floor 2 • The Lower units facing the entrance side have 1 floor that is ground lever and one floor below The Lower units have a fenced yard facing Federal Street. • The front of the building (parking lot side) faces Bridge Street. (see page 2) • The back of the building face Federal Street. (see page 3) • There are 3 entrances: A, B and C. • 3 Units have already installed since they thought it didn’t need approval since they were not visable • One Upper Unit recently began the installation which was halted by the condo association since we realized that it would need approval due to the visibility • Currently, there are 3 upper units requesting approval to install Unit C4, B3 and B4. Bridge Street View from the parking lot C2 + C4 B2 + B4 “C” units “C” units “B” units“B” units“A” units“A” units C2 is the unit already installed. C4 would be to the right of it. These would be same locations for “B” and “A”units. These are behind the rhododendron bushes and the tall hedge. They are not visable from the parking lot. There would also be a conduit that would extend to the 3rd floor for the upper units (shown in the supplied drawing. Page 2 of 3 B4B3 C4 C3 Federal Street View “C” units “A” units “B” units Page 3 of 3 C3 C4 B3 B4 A3 A4 C3 is the unit already installed, but only on this side. The photo to your left, shows the view from Federal Street. The lower units would have the equipment in their yards which is behind a tall fence and not visable at all from the street. New Salem Condominium II Association 28 Federal Street, Salem, MA 01970 Updated: 05.19.22 Conditions for Removing Old AC Units and Installing New Mini-Split Units ●This work will require 100% approval from abutting units and 66% of all owners and is to be done based on the following conditions: ●Exterior piping and conduit will be installed on the clapboards and will be painted to match the clapboard color. ●Wall penetrations will be done to maintain the integrity of the building envelope. ●When removing existing AC units all trim boards are to be removed. Openings to be framed to match existing conditions and be insulated and water sealed. ●All materials and colors to match existing. Clapboard joints to be staggered. Trim boards and panels to be Azek PVC. Clapboards to be Hardy Siding Products. ●All work to be done by licensed contractors and they are to provide certificates of insurance for workers compensation and liability coverage. ●All work, materials and colors to be approved by the NSCII building committee. These conditions shall apply to all present and future mini-split AC installations. ●Exterior conduit uses only 90 degree angles, is the width of our siding and horizontal runs installed over a siding run not straddling it, when possible. New Salem Condominiums II 06.08.21 Updated: 04.27.22 Conditions for Removing Old AC Units and Installing New Mini-Split Units This work will require 100% approval from abutting units and 66% of all owners and is to be done based on the following conditions: Exterior piping and conduit will be installed on the clapboards and will be painted to match the clapboard color. Wall penetrations will be done to maintain the integrity of the building envelope. When removing existing AC units all trim boards are to be removed. Openings to be framed to match existing conditions and be insulated and water sealed. All materials and colors to match existing. Clapboard joints to be staggered. Trim boards and panels to be Azek PVC. Clapboards to be Hardy Siding Products. All work to be done by licensed contractors and they are to provide certificates of insurance for workers compensation and liability coverage. All work, materials and colors to be approved by the NSCII building committee. These conditions shall apply to all present and future mini-split AC installations. Adrian Vasile 28B Federal Street, Unit B1 Salem, MA 01970 New Salem Condominium II (NCSII) Late Fee Generated February 2021 Original Total: $50.00 to be collected Date: July 21, 2021 URGENT: PLEASE RECTIFY THIS MATTER IMMEDIATELY Dear Adrian Vasile, Despite our previous reminder, the NSCII late fee remains unpaid. As such, we would appreciate you making this payment as soon as possible. The delay of payment causes a negative impact on the NSCII volunteer staff trying to reconcile financial books. DUE AMOUNT: $45.00 PLEASE REMIT PAYMENT TO: New Salem Condominium II We regret to advise that unless payment is received by August 15, 2021 this collection will be passed over to our debt collection agency/lawyer. Any additional fees inquired will be passed on to yourself. You have the right to dispute this debt by submitting written notice within thirty (30) days of receiving this letter. If this letter is not disputed within the thirty (30) day time-frame then the collection will be considered accepted by the debtor. Sincerely, Board of Managers, New Salem Condominium II New Salem Condominium II (NCSII) 28 Federal Street, Salem, Massachusetts 01970 Bridge Street View from the parking lot Page 1 of 3 Page 2 of 3 Federal Street Side Page 3 of 3 Job Name: System Reference:Date: Indoor Unit: MSZ-GL15NA Outdoor Unit: □ MUZ-GL15NA-U1 □ MUZ-GL15NA-U2 Wireless Remote Controller GENERAL FEATURES •Slim wall-mounted indoor units provide zone comfort control • The outdoor unit powers the indoor unit, and should a power outage occur, the system is automatically restarted when power returns • INVERTER-driven compressor and LEV provide high efficiency and comfort while using only the energy needed to maintain maximum performance • Multiple fan speed options: Quiet, Low, Medium, High, Super-high, Auto • Multiple control options available: - Hand-held Remote Controller (provided with unit) - kumo cloud® smart device app for remote access - Third-party interface options - Wired or wireless controllers • Quiet operation • Smart Set: recalls a preferred preset temperature setting at the touch of a button • Blue Fin anti-corrosion treatment applied to the outdoor unit heat exchanger for increased coil protection and longer life SUBMITTAL DATA: MSZ-GL15NA & MUZ-GL15NA 15,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. M-SERIES Cooling1 Maximum Capacity BTU/H 18,200 Rated Capacity BTU/H 14,000 Minimum Capacity BTU/H 3,100 Maximum Power Input W 2,000 Rated Power Input W 1,080 Moisture Removal Pints/h 2.7 Sensible Heat Factor 0.78 Power Factor %97 / 97 Heating at 47°F2 Maximum Capacity BTU/H 20,900 Rated Capacity BTU/H 18,000 Minimum Capacity BTU/H 4,800 Maximum Power Input W 2,010 Rated Power Input W 1,600 Power Factor %98 / 98 Heating at 17°F3 Maximum Capacity BTU/H 16,400 Rated Capacity BTU/H 12,200 Maximum Power Input W 1,850 Rated Power Input W 1,190 Heating at 5°F4 Maximum Capacity BTU/H 13,680 Maximum Power Input W 1,570 Heating at -4°F5 Maximum Capacity BTU/H 11,160 Heating at -13°F6 Maximum Capacity BTU/H - Efficiency SEER 21.6 EER1 13.0 HSPF (IV)11.7 COP at 47°F2 3.30 COP at 17°F in Maximum Capacity3 2.60 COP at 5°F in Maximum Capacity4 2.55 ENERGY STAR® certified units (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body.) YES Electrical Voltage, Phase, Frequency 208/230V, 1 phase, 60Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 24 Short-circuit Current Rating (SCCR)kA 5 Recommended Fuse/Breaker Size (Outdoor)A 15 Recommended Wire Size (Indoor - Outdoor)AWG 14 Indoor Unit MCA A 1 MOCP A 15 Blower Motor Full Load Amperage A 0.76 Blower Motor Output W 30 SPECIFICATIONS: MSZ-GL15NA & MUZ-GL15NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Airflow Rate at Cooling, Dry CFM 533-420-335-272-205 Airflow Rate at Cooling, Wet CFM 498-385-300-237-170 Airflow Rate at Heating, Dry CFM 463-367-304-247-205 Sound Pressure Level (Cooling)dB(A)49-44-38-32-26 Sound Pressure Level (Heating)dB(A)46-40-35-30-26 Drain Pipe Size In. (mm)5/8 (15.88) Heat Exchanger Type Plate fin coil External Finish Color Munsell 1.0Y 9.2/0.2 Unit Dimensions W: In. (mm)31-7/16 (798) D: In. (mm)9-1/8 (232) H: In. (mm)11-5/8 (295) Package Dimensions W: In. (mm)33-1/2 (850) D: In. (mm)12 (300) H: In. (mm)14 (350) Unit Weight Lbs. (kg)22 (10) Package Weight Lbs. (kg)26 (11.5) Indoor Unit Operating Temperature Range Cooling Intake Air Temp (Maximum / Minimum)*°F 90 DB, 73 WB / 67 DB, 57 WB Heating Intake Air Temp (Maximum / Minimum)°F 80 DB / 70 DB Outdoor Unit MCA A 10 MOCP A 15 Fan Motor Full Load Amperage A 0.5 Fan Motor Output W 55 Airflow Rate CFM 1,243 / 1,229 Refrigerant Control LEV Defrost Method Reverse cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling1 dB(A)49 Sound Pressure Level, Heating2 dB(A)51 Compressor Type DC INVERTER-driven Compressor Model SNB130FQBMT Compressor Rated Load Amps A 7.4 Compressor Locked Rotor Amps A 9.3 Compressor Oil Type // Charge oz.FV50S // 11.8 External Finish Color Munsell 3Y 7.8/1/1 Base Pan Heater Optional Unit Dimensions W: In. (mm)31-1/4 (800) D: In. (mm)11-1/6 (285) H: In. (mm)21-5/10 (550) Package Dimensions W: In. (mm)37 (940) D: In. (mm)14-15/16 (380) H: In. (mm)24-13/16 (630) SPECIFICATIONS: MSZ-GL15NA & MUZ-GL15NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit Weight Lbs. (kg)81 (37) Package Weight Lbs. (kg)90 (40) Outdoor Unit Operating Temperature Range Cooling Air Temp (Maximum / Minimum)*°F 115 / 14 Cooling Thermal Lock-out / Re-start Temperatures**°F -1 / 3 Heating Air Temp (Maximum / Minimum)°F 75 / -4 Heating Thermal Lock-out / Re-start Temperatures**°F -9 / -4 Refrigerant Type R410A Charge Lbs, oz 2, 9 Piping Gas Pipe Size O.D. (Flared)In. (mm)1/2 (12.7) Liquid Pipe Size O.D. (Flared)In. (mm)1/4 (6.35) Maximum Piping Length Ft. (m)65 (20) Maximum Height Difference Ft. (m)40 (12) Maximum Number of Bends 10 Notes AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) 1Cooling (Indoor // Outdoor)°F 80 DB, 67 WB // 95 DB, 75 WB 2Heating at 47°F (Indoor // Outdoor)°F 70 DB, 60 WB // 47 DB, 43 WB 3Heating at 17°F (Indoor // Outdoor)°F 70 DB, 60 WB // 17 DB, 15 WB Conditions 4Heating at 5°F (Indoor // Outdoor)°F 70 DB, 60 WB // 5 DB, 4 WB 5Heating at -4°F (Indoor // Outdoor)°F 70 DB, 60 WB // -4 DB, -5 WB *Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. **System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures. SPECIFICATIONS: MSZ-GL15NA & MUZ-GL15NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Anti-allergy Enzyme Filter □ MAC-408FT-E kumo touch™ RedLINK™ Wireless Controller □ MHK2 Deluxe MA Remote Controller1 □ PAR-40MAAU Simple MA Controller1 □ PAC-YT53CRAU-J Touch MA Controller1 □ PAR-CT01MAU-SB Wired Remote Sensor □ M21-EAA-307 Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1 System Control Interface2 □ MAC-334IF-E Wireless Interface 2 □ PAC-USWHS002-WF-2 Thermostat Interface □ PAC-US444CN-1 kumo station®□ PAC-WHS01HC-E USNAP Interface □ PAC-WHS01UP-E IT Extender □ PAC-WHS01IE-E BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1 Lockdown Bracket for Hand-held Remote Controllers □ RCMKP1CB Blue Diamond Sensor Extension Cable —15 Ft.□ C13-103 Blue Diamond Alarm Extension Cable —6.5 Ft.□ C13-192 Blue Diamond MultiTank —collection tank for use with multiple pumps □ C21-014 Blue Diamond Rubber Foot Pads □ F10-010 Mini Condensate Pump —230 volt application □ SI30-230 MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (110V) up to 48,000 BTU/ H[recommended] □ X87-711 - 110V Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) [recommended]□ X87-721 - 208/230V MicroBlue Blue Diamond Mini Condensate Pump (110/208/230V) up to 18,000 BTU/H □ X85-003 Fascia Kit for MicroBlue Pump – mounts the MicroBlue and sensor directly beneath the indoor unit □ T18-016 Drain Pan Level Sensor □ SS610E (30A/600V/UL) [fits 2" X 4" utility box] - Black □ TAZ-MS303 (30A/600V/UL) [fits 2" X 4" utility box] - White □ TAZ-MS303W 1 Requires MAC-334IF-E 2 Allows indoor units to connect to an MA Controller ACCESSORIES: MSZ-GL15NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Air Outlet Guide □ MAC-881SG Drain Socket □ MAC-860DS Optional Defrost Heater □ MAC-640BH-U Hail Guard □ HG-B4 Outdoor Unit 3-1/4 inch Mounting Base (Pair) - Plastic □ DSD-400P Condensing Unit Mounting Pad 16" x 36" x 3"□ ULTRILITE1 Outdoor Unit Stand —12" High □ QSMS1201M Outdoor Unit Stand —18" High □ QSMS1801M Outdoor Unit Stand —24" High □ QSMS2401M Heavy Duty Wall Mounting Bracket— Coated Steel □ QSWB2000M-1 Heavy Duty Wall Mounting Bracket —316 Series Stainless Steel □ QSWBSS 15' x 1/4" x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-15 30' x 1/4" x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-30 50' x 1/4" x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-50 65' x 1/4" x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-65 100' x 1/4" x 100' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-100 ACCESSORIES: MUZ-GL15NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch PipingInsulation ø1 - 3/8 O.D Liquid line ø1/4 19 - 11/16 (Flared connection ø1/4) Gas line ø3/8 16 - 15/16 (Flared connection: ø3/8 (06/09/12 KBTU/H), ø1/2 (15 KBTU/H) Drain hose Insulation ø1-1/8 O.D Connected part ø5/8 O.D DIMENSIONS: MSZ-GL15NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Unit: inch clear *1*1 4 in. or more when front and sides of the unit are clear *2 When any 2 sides of left, right and rear of the unit are clear holes (09/12/15 Btu/h) REQUIRED SPACE Liquid refrigerant pipe joint Refrigerant pipe (flared) Ø 1/4 Gas refrigerant pipe joint Refrigerant pipe (flared) Ø 3/8 (09/12 KBTU/H) Ø 1/2 (15 KBTU/H) 4 in. or m or e 14 i n . o r m o r e 8 in. o r m o r e * 2 4 in . o r m o r e FORM# MSZ-GL15NA / MUZ-GL15NA - 202003 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MUZ-GL15NA Specifications are subject to change without notice.© 2020 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. Job Name: System Reference:Date: GENERAL FEATURES •Variable speed INVERTER-driven compressor • Energy Star® certified1 (non-ducted) • M-NET connection through outdoor unit • Quiet outdoor unit operation as low as 50 dB(A) • New Intelligent Power Module (IPM) for reduced power loss • Selectable thermal lockout/restart function • Optional base pan heater • High pressure switch for additional protection • Thermal differential of +/-1° F from setpoint 1ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. SUBMITTAL DATA: MXZ-2C20NA2 1.5-TON MULTI-ZONE INVERTER HEAT-PUMP SYSTEM Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. M-SERIES Model number Outdoor unit MXZ-2C20NA2 Indoor unit type Non- Ducted Mix Ducted Cooling*1 Maximum Capacity Btu/h 20,000 Rated Capacity Btu/h 18,000 19,000 20,000 Minimum Capacity Btu/h 5,700 Maximum Power Input W 2,245 Rated Power Input W 1,417 1,709 2,000 Power Factor % 98.7 99.3 99.9 Heating at 47° F*2 Maximum Capacity Btu/h 25,000 Rated Capacity Btu/h 22,000 Minimum Capacity Btu/h 7,400 Maximum Power Input W 2,455 Rated Power Input W 1,641 1,706 1,771 Power Factor % 96.2 97.9 99.6 Heating at 17° F *3 Maximum Capacity Btu/h 15,500 15,000 14,500 Rated Capacity Btu/h 12,500 13,000 13,500 Maximum Power Input W 1,750 1,780 1,810 Rated Power Input W 1,300 1,325 1,350 Heating at 5° F *4 Maximum Capacity Btu/h 11,100 11,000 10,900 Maximum Power Input W 1,600 1,625 1,650 Efficiency SEER 20.00 18.00 16.00 EER *1 12.70 11.35 10.00 HSPF (IV)10.00 9.65 9.30 COP at 47° F *2 3.93 3.78 3.64 COP at 17° F *3 2.82 2.87 2.93 ENERGY STAR® Certified YES NO NO Electrical Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz Guaranteed Voltage Range V AC 187 - 253 Voltage: Indoor - Outdoor, S1-S2 V AC 208V / 230 Voltage: Indoor - Outdoor, S2-S3 V DC 12-24 Voltage: Indoor - Remote controller V DC 24 Recommended Fuse/Breaker Size A 20 SPECIFICATIONS: MXZ-2C20NA2 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Model number Outdoor unit MXZ-2C20NA2 Indoor unit type Non- Ducted Mix Ducted Recommended Wire Size (Indoor - Outdoor) AWG AWG14 Outdoor unit MCA A 17.2 Fan Motor Full Load Amperage A 1.77 Fan Motor Output W 64 Airflow Rate CFM 1,342 / 1,458 Refrigerant Control Liner Expansion Valve Defrost Method Reverse Cycle Heat Exchanger Type Plate fin coil Sound Pressure Level, Cooling*1 dB(A)50 Sound Pressure Level, Heating*2 dB(A)54 Compressor Type Twin Rotary type Compressor Model SNB140FQUH2T Compressor Motor Output kW 1.5 Compressor Rated Load Amps A 10.7 Compressor Locked Rotor Amps A 15.5 Compressor Oil Type // Charge oz.NEO22 / 20.3 External Finish Color Munsell 3.0Y 7.8/1.1 Base Pan Heater Optional Unit Dimensions W: In. [mm]33-1/16 [840] D: In. [mm]13 [330] H: In. [mm]27-15/16 [710] Package Dimensions W: In. [mm]40 [1,010] D: In. [mm]18-1/2 [470] H: In. [mm]33-1/2 [850] Unit Weight Lbs. [kg]126 [57] Package Weight Lbs. [kg]147 [67] Outdoor unit operating temperature range Cooling Intake Air Temp (Maximum / Minimum) °F 14 to 115 Heating Intake Air Temp (Maximum / Minimum) °F 5 to 75 Thermal Lock-out / Re-start Temperatures °F Cooling: 10.4 / 14 Heating: 1.5 / 5 SPECIFICATIONS: MXZ-2C20NA2 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Model number Outdoor unit MXZ-2C20NA2 Indoor unit type Non- Ducted Mix Ducted Refrigerant Type R410A Charge Lbs., Oz.3, 15 Indoor unit connection Maximum Number of Connected IDU 2 Minimum Number of Connected IDU 2 Maximum connected capacity Btu/h 24,000 Minimum connected capacity Btu/h 12,000 Piping Gas Pipe Size O.D. (Flared)In. [mm]3/8 [9.52] Liquid Pipe Size O.D. (Flared)In. [mm]1/4 [6.35] Total Piping Length Ft. [m]164 [50] Maximum Height Difference, ODU above IDU Ft. [m]33 [10] Maximum Height Difference, ODU below IDU Ft. [m]49 [15] Farthest Piping Length from ODU to IDU Ft. [m]82 [25] Maximum Number of Bends 50 AHRI Rated Conditions (Rated data is determined at a fixed compressor speed) *1 Cooling (Indoor // Outdoor)°F 80°F DB, 67°F WB // 95°F DB, 75°F WB *2 Heating at 47°F (Indoor // Outdoor)°F 70°F DB, 60°F WB // 47°F DB, 43°F WB *3 Heating at 17°F (Indoor // Outdoor)°F 70°F DB, 60°F WB // 17°F DB, 15°F WB Conditions *4 Heating at 5°F (Indoor // Outdoor)°F 70°F DB, 60°F WB // -4°F DB, -5°F WB For reference to connected capacity charts, please refer MXZ-2C20NA2-U1 Operational Performance. Notes: SPECIFICATIONS: MXZ-2C20NA2 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. Joint Pipe Port Adapter size: 3/8" x 5/8"□ PAC-SG76RJ-E Port Adapter size: 1/4" x 3/8"□ PAC-493PI Port Adapter size: 3/8" X 1/2"□ MAC-A454JP-E Port Adapter size: 1/2" X 3/8"□ MAC-A455JP-E Port Adapter size: 1/2" X 5/8"□ MAC-A456JP-E Air Discharge Guide □ MAC-856SG Base Pan Heater □ PAC-646BH-E Control Cable □ CW162S 3-pole Disconnect □ TAZ-MS303 M-NET Adapter □ PAC-IF01MNT-E Wall Mounting Bracket (Powder-coated Steel)□ QSWB2000M-1 Wall Mounting Bracket (316 Series Stainless Steel)□ QSWBSS Outdoor Unit Mounting Pad 24" x 42" x 3"□ ULTRILITE2 MiniSplit Mounting Stand-Dual Fan models - 12"□ QSMS1202M MiniSplit Mounting Stand-Dual Fan models - 18"□ QSMS1802M MiniSplit Mounting Stand-Dual Fan models - 24"□ QSMS2402M Diamondback Linesets*1 1/4 x 1/2 x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-15 1/4 x 1/2 x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-30 1/4 x 1/2 x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-50 1/4 x 1/2 x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-65 1/4 x 1/2 x 100' / 1/2" Lineset (Twin-Tube Insulation)□ MLS141212T-100 3/8 x 5/8 x 10' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-10 3/8 x 5/8 x 15' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-15 3/8 x 5/8 x 30' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-30 3/8 x 5/8 x 50' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-50 3/8 x 5/8 x 65' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-65 3/8 x 5/8 x 100' / 1/2" Lineset (Twin-Tube Insulation)□ MPLS385812T-100 *1 Linesets are indoor unit specific and will be listed in the IDU information - the Joint Pipe adaptors are used in this application ACCESSORIES: MXZ-2C20NA2 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc. 17 Connectingwire hole 1-25/32”18-1/829/32”3-5/16”5-5/16”11-25/32”14-3/16”27-15/16”9-7/16”7-7/8” 1-3/16”33-1/16” Unit A GAS GAS LIQ LIQ LIQ 1/4”(ø6.35)FLARE GAS 3/8”(ø9.52)FLARE Unit B Connectingwire hole 1-1/32” 13” 2-19/32” 1/2”(Bolt Pitch)(Foundation Bolt M8) 4-(13/32”×13/16”) Oval Hole 3-ø(1-5/16”) Drain hole AirInlet Air Inlet Air Outlet 14-3/16”15/32” 23/32”21/32”1-11/32”2-9/16”12-3/8”8-5/32” 6-21/32”6-23/32”19-11/16”11/16”11/16”15-19/32”Handle Unit: inch (mm) OUTLINES AND DIMENSIONS5 Lock nut Connector Grounding terminal Conduit cover OBH702F FORM# MXZ-2C20NA2 - 201805 1340 Satellite Boulevard, Suwanee, GA 30024 Toll Free: 800-433-4822 www.mehvac.com DIMENSIONS: MXZ-2C20NA2 Specifications are subject to change without notice. © 2018 Mitsubishi Electric US, Inc.