pv MULTI-FAMILY PLAN VIEW
Name: Martha Delaney Site ID (Unit 1): 5145360 Finished Sq. Ft: 2088 # Floors: 2.5
Phone: 9784904658 Site ID (Unit 2): 5145358 Year Built: 1890 Occupants: 4
Address: 181 Federal St Site ID (Unit 3): Housing Type? Duplex
Salem MA 01970 Site ID (Unit 4):
Electric Acct# (unit 1): 88097389 Electric (2): 008264042 Electric (3): Electric (4):
Gas Acct# (unit 1):04295213750 Gas (2):04295213786 Gas (3): Gas (4):
BASEMENT INSPECTION
Unit EXISTING SPEC'IN N/SQ. FT. 40 A.)A/S
Crawl Ceiling
Crawl Rim Joist CAZ
Bsmt RJ 30
Bsmt R1
apor rier sgft. Bsmt Door
Y N Blower Door? WALLS&GARAGE Drill Location?
Unit SIDING CEIL. HEIGHT EXISTING SPEC'ING SQ. FT.
Exterior Wall 1 1 W.Clap 8.5 DPC 4' 1350 Framing
Exterior Wall 2 2 W.Clap 8.5 DPC 4' 1350 2 x 4 x 1 Balloon Platform
Exterior W x x Balloon/Platform
Exterior Wall 4 x
Overhang x x Ballo Pla orm
Garage Wall x x
Garage Ceiling
• — 40
-C- - A.)W.Shingle DPC 4" 1350sgft
B.)W.Shingle DPC 4" 1350sgft
31 — —
I
I
_ I
_ I
1 st floor 2nd floor(identical)
I
WORK SPEC'D BUT NOT CONTRACTED Insulation Removal Unit: 1 2 3 4
Attic Basement Crawlspace Other: Unit: Q.FT. Sweeps:
Kneewa I I Overhang/Garage
Ductwork Exterior Walls WX Stripping:
ROAD BLOCKS PRESENT?(MANDATORY)
Unit 1 2 3 4 Unit 3 Unit 1 2 4
K&T Y/ Y/ Y/ Y/N Moisture Y/N Y/ /N Combustion Sfty N N Y/ N
Asbestos Y/ Y/ Y/ Y/N Mold>100 s .ft Y/N Y N Y N CO Detector MissingY/ Y/ Y/ N
Vermiculite Y/ Y/ Y/ Y/ Structl Concern Y/N Y N YM Other(indicate unit)
Notes:
Plaster walls
KW WALL AND KW FLOOR Blind Spec? ❑ OR KW SLOPE AND GABLE END Blind Spec? ❑
Why? Unit: Why? Unit:
F R A MJNG EXISTING SPEC'ING SO.FT. FRAMING EXISTING SPEC'ING SQ.FT.
WALL X X tF--C�n
SLOPE X XFLOOR X X GABLE X X
ACCESS X TRANS
TRANS X X -meV" ATTIC
ATTIC C-er9Y" SLOPE X X
SLOPE X X EXISTING VENTING?
EXISTING VENTING? EXISTING PIPES? Y/N
KW Ventin Vent BF BF Hose Damming Sheathing Access pAccess KW Venting Vent BF Temp Access
A.)W.Clapboard DPC 4" 150sgft
ATTIC NO SPEC, CONDITIONED LIVING SPACE.
HEATING SOURCE IS PREVALENT.
OPENINGS AND CRACKS IN ATTIC SLOPE.
KNEE WALL LESS THAN 2 1/2 FEET HEADROOM.
Gable Wall SPEC
2.8ft
4.3ft
C 6.8ft
1
2.5 ft
J
14ft
DUCI Ducts Insulated?EX
Duct Linear Ft. Duc ation
Duct Square Ft. 46uct Insulatio emoval
Duct Air Sealing Hours Unit. —
x x ATTIC 1 Blind Spec?El x ATTIC 2 Blind Spec? ❑ -
Unit: EXISTING SPEC'ING FT. Unit: TING SPEC'ING SQ. FT.
Unfloored Unfloored Unit 1 1 DS s
Floored Floored Mixed ation
• Cath Slope at Slope Unit "Loos
Walls Walls ross Battin
Access Access WHF Box Unit:
Sheathing Access Unit:
Venting Propavents Venf F Hose Damming Venting Propavents Vent BF BF Ho Damming R.L.Covers Unit:
Temp Access Unit:
Q Q Roof Type: Asphalt