3 Smith St Layout PlansSHEET: SCALE: DATE: 05/01/2024 THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY A-1 PROJECT ADDRESS: 3 SMITH ST. SALEM, MA NO SCALE GENERAL NOTES: DRAWINGS ARE REPRESENTATIVE DOCUMENTS TO FACILITATE CONSTRUCTION. CONTRACTOR SHOULD FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO CONSTRUCTION. THE HEIGHTS OF GRADE INDICATED ON THE DRAWINGS ARE APPROXIMATE AND ARE PROVIDED FOR INFORMATION ONLY. THE ACTUAL GRADE ELEVATIONS SHOULD BE IDENTIFIED IN A SITE PLANS BY A REGISTERED LAND SURVEYOR. NOTIFY DESIGNER OF ANY ALTERATIONS OR DISCREPANCIES BEFORE PROCEEDING WITH WORK AND IMMEDIATELY UPON DISCOVERY. SECTIONS AND DETAILS SHOWN, WHILE DRAWN FOR SPECIFIC LOCATIONS ARE INTENDED TO ESTABLISH THE GENERAL TYPES OF DETAILS TO BE USED THROUGHOUT. WORK NOT INDICATED ON A PART OF THE DRAWINGS BUT REASONABLY IMPLIED TO BE SIMILAR TO THAT SHOWN AT CORRESPONDING PLACES, SHALL BE REPEATED. SHOULD THE CONTRACTOR AND/OR OWNER DESIRE ANY ALTERATIONS TO THIS SET OF PLANS, OR IF ANY DISCREPANCIES OR OMISSIONS ARE IDENTIFIED, THE SAME MUST BE PRESENTED/ COMMUNICATED IN WRITING IMMEDIATELY. UNDER NO CIRCUMSTANCE SHALL THE WORK CONTINUE UNTIL A REASONABLE SOLUTION IS AGREED UPON BETWEEN ALL STAKEHOLDERS. CONTRACTOR TO VERIFY AND/OR ESTABLISH ALL EXISTING CONDITIONS AND DIMENSIONS AT THE SITE AND TO NOTIFY OWNER/DESIGNER OF ANY DISCREPANCIES AND/OR DEVIATIONS FROM DRAWINGS. PROPOSED REMEDIES, IF REQUIRING ADDITIONAL WORK, ARE TO BE SUBMITTED FOR APPROVAL IN THE FORM OF WRITTEN CHANGE ORDERS TO THE OWNER IN ACCORDANCE WITH THE TERMS OF THE CONTRACT BEFORE ORDERING MATERIAL OR COMMENCING WITH WORK. CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINNING OR FABRICATING ANY WORK. DRAWINGS SHALL NOT BE SCALED BY HAND. USE ONLY PRINTED DIMENSIONS TO IDENTIFY SIZE AND DIMENSION OF MATERIALS AS SHOWN. CONTACT THE DESIGNER TO VERIFY ANY DIMENSION THAT HAS BEEN OMITTED FROM THESE PLANS. CONTRACTOR AND SUB-CONTRACTORS SHALL PERFORM ALL CUTTING AND PATCHING REQUIRED TO COMPLETE WORK, OR MAKE PARTS FIT TOGETHER PROPERLY WITHOUT COMPROMISING QUALITY OF WORK. MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION SYSTEM ARE INDICATED ON ARCHITECTURAL DRAWINGS FOR COORDINATION ONLY. BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. ALL NAILS AND FASTENERS IN AREAS PRONE TO MOISTURE SHALL BE "HOT DIPPED GALVANIZED" UNLESS OTHERWISE NOTED. THE CONTRACTOR AND SUBCONTRACTORS SHALL KEEP SUFFICIENT WORKMEN ON THE JOB SITE AT ALL TIMES TO PERFORM WORK IN THE MOST EXPEDITIOUS MANNER CONSISTENT WITH GOOD WORKMANSHIP, SOUND BUSINESS PRACTICE AND IN THE BEST INTEREST OF THE OWNER. INCOMPETENT WORKERS WILL NOT BE RETAINED ON THE JOBSITE. FIRE SAFETY: STORE ALL CONSTRUCTION MATERIALS IN A SECURE AND LOCKED AREA CONTROLLED BY THE CONTRACTOR. AT NO TIME DURING THE WORK SHALL STORED MATERIALS OR TOOLS BLOCK OR IMPEDE A PATH OF EMERGENCY MEANS OF EGRESS. DO NOT ALTER OR NEGATE THE FIRE-RATING OF EXISTING CONSTRUCTION TO REMAIN. MAINTAIN FULL AND PROPER OPERATION OF THE BUILDING FIRE ALARM SYSTEM FOR THE DURATION OF THE WORK. PROVIDE FIRESAFING AT ALL PENETRATIONS MADE THROUGH NEW AND ETR FIRE-RATED CONSTRUCTION TO PROVIDE/MAINTAIN REQUIRED FIRE SEPARATION RATING. PROJECT ADDRESS: 3 SMITH ST. - SALEM, MA LICENSES: PLUMBING, FIRE PROTECTION, ELECTRICAL AND TELEDATA WORK SHALL BE PERFORMED BY QUALIFIED, EXPERIENCED PERSONS CURRENTLY LICENSED IN THEIR RESPECTIVE TRADE. WORK HOURS: COORDINATE THE SCHEDULING OF ALL WORK WITH THE OWNER, OR BUILDING MANAGER TO MINIMIZE DISRUPTIONS TO THE BUILDING OPERATIONS, AND ITS OCCUPANTS. OBTAIN AND FOLLOW AVAILABLE RULES AND PROCEDURES FOR WORK PERFORMED WITHIN THE BUILDING. COORDINATE WORK PROCEDURES WITH THE REQUIREMENTS OF THE LOCAL AUTHORITIES (WHERE APPLICABLE). PROTECTION OF FURNISHINGS: PROTECT ETR FURNITURE AND EQUIPMENT FROM DAMAGE AND DUST. COORDINATE TEMPORARY REMOVAL AND STORAGE OF FURNITURE AND EQUIPMENT WITH THE OWNER. CONTROLS: TAKE ALL REASONABLE MEASURES TO LIMIT DEMOLITION AND CONSTRUCTION NOISE FROM DISRUPTING EXISTING BUILDING OCCUPANTS. MAINTAIN OR PROVIDE APPROPRIATE EXITS AND EXITWAYS THROUGHOUT CONSTRUCTION. PLUMBING, MECHANICAL AND ELECTRICAL (PME) NOTES: TYPICAL TO ALL CONDITIONS UNLESS OTHERWISE INDICATED OR SPECIFIED: 1)STRUCTURAL MEMBERS SHALL NOT BE IMPAIRED OR UNDERMINED BY IMPROPER CUTTING OR DRILLING. 2)ALL PME WORK SHALL COMPLY WITH ALL APPLICABLE CODES, BE PERFORMED BY A LICENSED TRANSPERSONAL AND BE COMPLETED IN ACCORDANCE WITH THE DIRECTION OF ALL LOCAL BUILDING CODE OFFICIALS. SUB-CONTRACTORS AND TRADES-PERSONS ARE RESPONSIBLE FOR OBTAINING REQUIRED PERMITS FOR THEIR TRADE, SCHEDULING AND COMPLETING REQUIRED INSPECTIONS AND OPERATING ON A REASONABLE AND EFFICIENT SCHEDULE THAT DOES NOT DELAY THE WORK OF OTHER TRADES. 3)ALL MATERIALS SHALL BE SIZED IN ACCORDANCE WITH THE PROPOSED PLANS, ALLOWING FOR FUTURE EXPANSION IF INDICATED. ALL WORK SHALL BE INSTALLED SO THAT REQUIRED PARTS ARE READILY AVAILABLE AND ACCESSIBLE FOR INSPECTION, OPERATION, MAINTENANCE AND REPAIR. 4)ALL PRODUCTS, MATERIALS AND FIXTURES SHALL BE INSTALLED IN A MANNER CONSISTENT WITH SOUND PRACTICE AND QUALITY WORKMANSHIP. PROPOSED HEATING AND AIR CONDITION SYSTEM: AIR SOURCE HEAT PUMP WITH A HYDRONIC DUCTED AIR HEATING SYSTEM. DESIGN AND BUILD BY LICENSED HVAC CONTRACTOR ON SEPARATE PERMIT FRAMING NOTES: (USE BELOW UNLESS OTHERWISE NOTED) 1- USE STRONG DRIVE CONNECTORS AT ALL COLUMN TO BEAM CONNECTIONS. 2- ALL MULTI PLY BEAMS SHALL BE FASTENED PER MANUFACTURER'S RECOMMENDATION, UNLESS OTHERWISE SPECIFIED. 3- 3/4" T&G SUBFLOORING SHALL BE GLUED AND NAILED TO FRAMING MEMBERS AT 6" O.C.MIN. USE RING SHANK 8(d) NAILS. 4- USE STRONG DRIVE JOIST HANGERS AT ALL FLUSH CONNECTIONS TO BEARING BEAMS 5- COLUMNS SHALL BE CONTINUOUS TO FOUNDATION OR FOOTINGS IN BASEMENTS. CONSULT WITH DESIGN PROFESSIONAL IF CONTINUITY IS NOT POSSIBLE 6- SEE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ENGINEERED STRUCTURAL COMPONENTS. NO HOLES OR NOTCHES SHALL BE MADE TO ANY BEAM WITHOUT APPROVAL OF DESIGN PROFESSIONAL UNLESS ALLOWED IN MANUFACTURER'S INSTALLATION INSTRUCTIONS. 7- USE SIMPSON® METAL CONNECTORS AT ALL COLUMN TO BEAM CONNECTIONS AS WELL AS AT ALL COLUMN BOTTOM ATTACHMENTS. ALSO USE SIMPSON METAL CONNECTORS AT ALL JOIST TO BEAM AND BEAM TO BEAM CONNECTIONS. CONSULT WITH DESIGN PROFESSIONAL IF ANY CONNECTOR IS NOT SPECIFIED IN PLANS. 8- ALL STEEL BEAMS AND COLUMNS TO CONSIST OF Fy=50KSI STEEL GRADE 9- ALL KD & PT WOOD SHALL SET ALL CONSIST OF SPF#2 OR BETTER 10- INSTALL FIRE BLOCKING BETWEEN STORIES PER IRC R302.11, R602.8 11- ALL COLUMNS WHICH PENETRATE ANY HORIZONTAL FRAMED ASSEMBLY SHALL BE SOLID BLOCKED WITH GLUE AND NAILED KD 2X'S BLOCKING TO INSURE LOAD PATH CONTINUITY BETWEEN STORIES. ALL LOAD BEARING COLUMNS SHALL EVENTUALLY REACH A FOUNDATION WALL, FOOTING AND/OR A TRANSITIONAL BEAM. ANY DISCREPANCIES, IF ENCOUNTERED MUST BE COMMUNICATED WITH DESIGN PROFESSIONAL BEFORE PROCEEDING. 12- REPLACE EXISTING DAMAGED JOISTS/STUDS/RAFTERS. 13- ALL WINDOWS WITH THE EXPOSED FRAMING MUST BE REPLACED AS HEADER FOR A MINIMUM DBL 1 1/2" X 9 1/4" WITH DBL JACK STUDS. 14- BUILD TEMPORARY WALLS TO SUPPORT FLOORS AND BEAM SYSTEMS DURING REMOVAL AND REINSTALLATION OF NEW BEAMS, COLUMNS AND JOISTS 15- ALL STAIRCASE, HANDRAILS AND GUARDRAILS TO COMPLY WITH PROVISIONS OF IRC2015 CHAPTER 3 SECTIONS R311 AND R312 AND MA/CMR780 9th EDITION AMENDMENTS. **** IT IS THE CONTRACTOR'S AND/OR SUBCONTRACTOR'S RESPONSIBILITY TO UNDERSTAND THE INTENDED LOAD PATHS AND ENSURE VERTICAL ALIGNMENT OF ALL LOAD BEARING COMPONENTS BEFORE PERMANENT INSTALLATION. THE CONTRACTOR/SUBCONTRACTOR MUST ALSO NOTIFY THE DESIGN PROFESSIONAL IN WRITING OF SUCH CHANGES/VARIATIONS. IF THE ACTUAL SITE DIMENSIONS VARY/CHANGE MORE THAN 1" TO 2" FROM WHAT HAS BEEN DESIGNED AT ANY LOCATION, THE CONTRACTOR/SUBCONTRACTOR MUST OBTAIN WRITTEN PERMISSION FROM DESIGN PROFESSIONAL BEFORE EXECUTING THE WORK. ADDITIONALLY CONCRETE SLABS SHALL NOT BE POURED UNTIL ALL COLUMN BEARING FOOTINGS HAVE BEEN POURED AT THEIR DESIGNATED LOCATIONS**** FINISH NOTES: RENDERINGS ARE NOT TO SCALE; ALL RENDERINGS ARE FOR ARTISTIC DEPICTION ONLY. PLAN UPDATES MAY NOT BE REFLECTED IN RENDERINGS. RENDERINGS SHALL NOT BE USED FOR CONSTRUCTION. BASE BOARDS SHALL BE 6" IN ALL ROOMS, UNO. FINAL FINISHES SHALL BE CONFIRMED WITH THE HOME OWNER PRIOR TO APPLICATION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DISTRIBUTION OF DRAWINGS TO THE SUB-CONTRACTORS UNDER HIS JURISDICTION. THE CONTRACTOR IS TO COORDINATE THE WORK OF ALL SUB-CONTRACTORS, INCLUDING THE TIMING AND SCHEDULING OF THEIR WORK AND THE LAYOUT OF THEIR SYSTEMS. THE CONTRACTOR SHALL PROVIDE ALL SUB-CONTRACTORS WITH NECESSARY POWER AND ACCESS AND CONNECTIONS THROUGH FOUNDATION WALLS AS REQUIRED. THE CONTRACTORS SHALL ACKNOWLEDGE THAT CONSTRUCTION SITES ARE DIFFICULT AND DANGEROUS PLACES TO WORK BY NATURE. AS SUCH, ALL NECESSARY PRECAUTIONS WILL BE TAKEN TO ENSURE SAFETY AND GENERAL WELL BEING OF HIS EMPLOYEES. CONTRACTOR SHALL PROVIDE GUARDS, RAILS, BARRICADE, FENCES, CATCH PLATFORMS, BRIDGING, ETC., AS REQUIRED. CONTRACTORS AND SUB-CONTRACTORS SHALL FURNISH SAMPLES OF ALL MATERIALS, AND/OR FINISHES AS SPECIFIED FOR CONSTRUCTION AT THE REQUEST OF THE DESIGNER, OWNER OF GENERAL CONTRACTOR. SHEET, NOTES AND LEGENDS LIST OF DRAWINGS: A-1 PROJECT INFORMATION SHEET NOTES AND LEGENDS ILLUSTRATIVE IMAGES A-2 EXISTING SECOND FLOOR PLAN EXISTING ROOF PLAN EXISTING EXTERIOR ELEVATIONS A-3 DEMOLITION SECOND FLOOR PLAN DEMOLITION ROOF PLAN PROPOSED SECOND FLOOR PLAN PROPOSED ROOF PLAN PROPOSED CEILING FRAME PROPOSED ROOF FRAME PROPOSED CROSS SECTION NOTES, DETAILS, TABLE A-4 PROPOSED EXTERIOR ELEVATIONS PROPOSED PERSPECTIVES TABLES EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR 2368 9'-6" 14'-3" 1'-6" 3'-4" 9'-7" 9'-4" 3'-1" 2'-7" 4'-5" 9'-9" 11'-3" 11'-1 1/2" 14'-3" X 4'-8" 4'-3" X 8'-4" 9'-7" X 9'-4" 6'-11" X 4'-5" 10'-2" X 5'-6" BATH HALL BEDROOM BEDROOM MASTER BEDROOM EXISTING STAIRS EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 20'-6'' ROOF LEVEL EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOW EXISTING WINDOW 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 20'-6'' ROOF LEVEL EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOW EXISTING WINDOW 2 1/2 : 12 9 : 12 9 : 12 1 1/2 : 12 4 : 12 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 20'-6'' ROOF LEVEL EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWEXISTING WINDOW 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 20'-6'' ROOF LEVEL EXISTING WINDOWEXISTING WINDOW SHEET: SCALE: DATE: 05/01/2024 THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY A-2 PROJECT ADDRESS: 3 SMITH ST. SALEM, MA INDICATED EXISTING PLANS, EXISTING ELEVATIONS EXISTING SECOND FLOOR PLAN SCALE: 1/4" = 1'-0" EXISTING FRONT ELEVATION SCALE: 1/4" = 1'-0" EXISTING LEFT ELEVATION SCALE: 1/4" = 1'-0" EXISTING REAR ELEVATION SCALE: 1/4" = 1'-0" EXISTING RIGHT ELEVATION SCALE: 1/4" = 1'-0" EXISTING ROOF PLAN SCALE: 1/4" = 1'-0" EXISTING WINDOW DEMOLITION WINDOW DEMOLITION WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR 2368 9'-6" 14'-3" 1'-6" 3'-4" 9'-7" 9'-4" 3'-1" 2'-7" 4'-5" 9'-9" 11'-3" 11'-1 1/2" 14'-3" X 4'-8" 4'-3" X 8'-4" 9'-7" X 9'-4" 6'-11" X 4'-5" 10'-2" X 5'-6" BATH HALL BEDROOM BEDROOM MASTER BEDROOM EXISTING STAIRS EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN 2 1/2 : 12 9 : 12 9 : 12 1 1/2 : 12 4 : 12 DEMOLITION ROOF DEMOLITION ROOF DEMOLITION ROOF EXISTING ROOF TO REMAIN EXISTING WINDOW W01W01 W01W01 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISITNG DOOR EXISTING WINDOW 2368 S1S1 9'-6" 14'-3" 1'-6" 3'-4" 9'-7" 3'-1" 2'-7" 4'-5" 9'-9" 11'-3" 11'-1 1/2" 14'-3" X 9'-6" 4'-3" X 8'-4" 9'-7" X 9'-4" 6'-11" X 4'-5" 11'-2" X 11'-3" BATH HALL BEDROOM BEDROOM MASTER BEDROOM EXISTING STAIRS EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN PROPOSED WINDOW PROPOSED WINDOW 22 A-8 22 A-8 W1 A-3 W1 A-3 10 : 12 8'-5"9'-4" 25'-2 1/16" PROPOSED SHINGLE ROOF PROPOSED SHINGLE ROOF EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN 22 A-8 22 A-8 03 A-3 03 A-3 01 A-3 01 A-3 ROOF DORMER 04 A-3 04 A-3 1 1/2 : 12 2 1/2 : 12 10 : 126 : 12 EXISTING CEILING TO REMAIN PROPOSED CATHEDRAL CEILING NEW HEADERS: SEE TABLE 780 CRM - 5502.5 (2) ON PAGE A-3 EXISTING HEADERS 11 STAIRCASE NOTE: ALL STAIRCASE, HANDRAILS AND GUARDRAILS TO COMPLY WITH PROVISIONS OF IRC 2015 CHAPTER 3 SECTIONS R311AND R312 AND MA/CMR780 9th EDITION AMENDMENTS HEADERS: SEE TABLE 780 CRM - 5502.5 (2) ON PAGE A-8 COLUMN PADS: 24"x24"x12" CONCRETE FOOTING W/5 #5 BARS EACH WAY W/ CONTROL JOINTS PLEASE, SEE DETAIL 16 ON PAGE A-8 SONOTUBE: 12'' SONOTUBE W/4'' DEEP PSL SCHEDULE 2D SYMBOL TYPE PSL POST 4X4 PSL POST 6X6 HSS COLUMN 6X6 22 9'-4" EXISTING ROOF TO REMAIN EXISTING ROOF TO REMAIN 01 A-3 01 A-3 COLLAR TIE ON EACH RAFTERS (2X6) CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 12" LVL RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 6" PITCH CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 12" LVL RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 10" PITCH CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 12" LVL RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 10" PITCH 02 A-3 02 A-3 22 A-8 22 A-8 03 A-3 03 A-3 04 A-3 04 A-3 PD (2X4) PD (2X4) VIF POST DN TO (E) LALLY IN BASEMENT OR ADD NEW AT THIS LOCATION WITH A FOOTING VIF POST DN TO (E) LALLY IN BASEMENT OR ADD NEW AT THIS LOCATION WITH A FOOTING 2X10'' RAFTERS @16'' O.C. 2X10'' RAFTERS @16'' O.C. BEAM (2X12) RIDGE BOARD (2X12) 2X10'' RAFTERS @16'' O.C. For SI: 1 inch = 25.4 mm 01 - RIDGE DETAIL 02 - COLLAR TIE W1 - (TYP. EXTERIOR WALL) EXISTING WINDOW 10'-6" 9' 24'' MASTER BEDROOM EXISTING ROOF TO REMAIN PROPOSED NEW ROOF CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 12" RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 6" PITCH CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 12" RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 10" PITCH CONSTRUCTION ROOF · ASPHALT SHINGLES · ROOF UNDERLAYMENT · 5/8" CDX PLYWOOD · 12" RIDGE BOARD · SIMPSON RAFTER HANGERS · 2X10 RAFTERS @16". O.C. · SIMPSON H2.5A HURRICANE TIE · INSULATION, MIN R60 · 1X3 STRAPPING · 1/2" GWB · 10" PITCH 01 A-3 01 A-3 COLLAR TIE ON EACH RAFTERS (2X6) 03 A-3 03 A-3 EXISTING FLOOR JOISTS TO REMAIN P R O J E C T I O N R O O F 1 2 '' P I T C H W1W1 CATHEDRAL CEILING EXISTING ROOF TO REMAIN PROPOSED HEADER (3) 2" X 8" CONSTRUCTION WALL ·BUILDING UNDERLAYMENT ·1/2" CDX PLYWOOD SHEATHING ·2X6 #2 SPF STUDS, @ 16" OC ·INSULATION, MIN R30 ·1/2" GWB PD (2X4) BEAM 2X12 EXISTING WINDOW 03 - SOFFIT DETAIL EXISTING STAIRS EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN EXISTING WALL, TO REMAIN WINDOW SCHEDULE 3D EXTERIOR ELEVATION NUMBER QTY FLOOR R/O WIDTH HEIGHT EGRESS DESCRIPTION W01 2 2 30 1/2"X48 1/2"29 1/2 "47 1/2 "DOUBLE HUNG PROPOSED WINDOW PROPOSED WINDOW 04 - RAFTER HEAD DETAIL EXISTING NEW EXISTING RAFTERS EXISTING LEDGER 2X10 RAFTERS BEAM 2X12 SHEET: SCALE: DATE: 05/01/2024 THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY A-3 PROJECT ADDRESS: 3 SMITH ST. SALEM, MA DEMOLITION SECOND FLOOR PLAN SCALE: 1/4" = 1'-0" PROPOSED ROOF PLAN SCALE: 1/4" = 1'-0" PROPOSED ROOF FRAME SCALE: 1/4" = 1'-0" DEMOLITION ROOF PLAN SCALE: 1/4" = 1'-0" PROPOSED SECOND FLOOR PLAN SCALE: 1/4" = 1'-0" NOTES: CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT BUILDING MEETS ALL REQUIRED LOCAL, STATE AND FEDERAL BUILDING CODES. ANY DISCREPANCIES/ CONFLICTS IN PLANS AND WITH LOCAL, STATE AND FEDERAL BUILDING CODES SHOULD BE BROUGHT TO THE ATTENTION OF THE CLIENT AND/ OR DESIGNER IMMEDIATELY. CONTRACTOR IS RESPONSIBLE FOR MEANS AND METHODS OF CONSTRUCTION CONTRACTOR RESPONSIBLE FOR ALL FLASHING DETAILS. CONTRACTOR TO VERIFY LOCATION OF ALL MECHANICAL EQUIPMENT, VENT LOCATIONS W/ CLIENT. ALL THROUGH WALL VENTS SHOULD BE LOCATED OFF FRONT ELEVATION WHERE POSSIBLE CONTRACTOR IS RESPONSIBLE FOR MAKING SURE ALL LOAD PATHS ARE CORRECTLY ESTABLISHED AND DIRECTED TO APPROPRIATE BEARING LOCATIONS. FRAMING PLANS MAY REQUIRE HEADERS/ GIRDERS NOT DESCRIBED. ANY PROBLEMS/DISCREPANCIES PLEASE BRING TO IMMEDIATE ATTENTION OF DESIGNER. CONTRACTOR TO PROVIDE CONTINUOUS SOLID BLOCKING BETWEEN ALL STUDS AND POSTS CARRYING STRUCTURAL LOADS WHERE REQUIRED. CONTRACTOR TO CONFIRM LOCATIONS OF GIRDER POCKETS FOR DROPPED GIRDERS DEMOLITION PLANS, PROPOSED PLANS, PROPOSED FRAME PLANS, DETAILS, NOTES & TABLE INDICATED PROPOSED CROSS SECTION - S1 SCALE: 1/2" = 1'-0" EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOW W01W01W01W01 24'' 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 22'-7'' ROOF LEVEL EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOW W01W01W01W01 EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOWEXISTING WINDOW 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 22'-7'' ROOF LEVEL EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING DOOR EXISTING WINDOWEXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 22'-7'' ROOF LEVEL EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOW EXISTING WINDOWEXISTING WINDOW 1'-8'' FIRST FLOOR LEVEL 9'-10'' SECOND FLOOR LEVEL 22'-7'' ROOF LEVEL EXISTING WINDOWEXISTING WINDOW SHEET: SCALE: DATE: 05/01/2024 THE PAPER SIZE NEEDS TO BE 24" X 36" TO SCALE PROPERLY A-4 PROJECT ADDRESS: 3 SMITH ST. SALEM, MA INDICATED PROPOSED EXTERIOR ELEVATIONS, PROPOSED PERSPECTIVES, NOTES & TABLES PROPOSED FRONT ELEVATION SCALE: 1/4" = 1'-0" PROPOSED LEFT ELEVATION SCALE: 1/4" = 1'-0" PROPOSED REAR ELEVATION SCALE: 1/4" = 1'-0" PROPOSED RIGHT ELEVATION SCALE: 1/4" = 1'-0" PROPOSED PERSPECTIVES NO SCALE DEAD LOAD = 10 psf DEAD LOAD = 20 psf MAXIMUM RAFTER SPANSa 2x4 2x6 2x8 2x10 2x12 2x4 2x6 2x8 2x10 2x12 SPECIES AND GRADE RAFTER SPACING (inches) DOUGLAS FIR-LARCH SS DOUGLAS FIR-LARCH #1 DOUGLAS FIR-LARCH #2 DOUGLAS FIR-LARCH #3 HEM-FIR SS HEM-FIR #1 HEM-FIR #2 HEM-FIR #3 SOUTHERN PINE SS SOUTHERN PINE #1 SOUTHERN PINE #2 SOUTHERN PINE #3 SPRUCE-PINE-FIR SS SPRUCE-PINE-FIR #1 SPRUCE-PINE-FIR #2 SPRUCE-PINE-FIR #3 (feet - inches) (feet - inches) (feet - inches) (feet - inches) (feet - inches) (feet - inches) (feet - inches) (feet - inches) (feet - inches) (feet - inches) 7-8 7-1 6-9 5-2 7-3 7-0 6-7 5-0 7-6 7-1 6-1 4-8 7-1 6-8 6-8 5-0 15-11 13-2 12-6 9-7 15-0 13-0 12-2 9-4 15-7 13-5 11-7 8-9 14-8 12-4 12-4 9-4 12-1 10-5 9-10 7-7 11-5 10-3 9-7 7-4 11-10 10-7 9-2 6-11 11-2 9-9 9-9 7-4 19-9 16-1 15-3 11-8 19-1 15-11 14-10 11-5 19-11 15-9 13-9 10-7 18-0 15-1 15-1 11-5 22-10 18-8 17-9 13-6 22-1 18-5 17-3 13-2 23-7 18-8 16-2 12-6 20-11 17-6 17-6 13-2 7-8 6-7 6-3 4-9 7-3 6-6 6-1 4-8 7-6 6-7 5-8 4-4 7-1 6-2 6-2 4-8 11-10 9-8 9-2 7-0 11-5 9-6 8-11 6-10 11-10 9-10 8-5 6-5 10-9 9-0 9-0 6-10 14-11 12-2 11-7 8-10 14-5 12-10 11-3 8-8 15-7 12-5 10-9 8-1 13-8 11-5 11-5 8-8 18-3 14-11 14-2 10-10 17-8 14-9 13-9 10-6 18-6 14-7 12-9 9-10 15-11 13-11 13-11 10-6 21-2 17-3 16-5 12-6 20-5 17-1 15-11 12-3 21-10 17-3 15-0 11-7 19-4 16-2 16-2 12-3 TABLE R802.5.1(4) RAFTER SPANS FOR COMMON LUMBER SPECIES (Ground snow load = 50 psf, ceiling not attached to rafters, l/A = 180) 16