Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
7 COTTAGE STREET - BUILDING JACKET
L.. _ f �� -,, ,V REPORT DATE: 7—/7^ 7 S ADDRESS: 77 Co'/ Si'jeEc,T, NA41ki I%L /9ow,A om d7 k le k� � OWNER: - USE' GROUP: NUMBER-OF-STORIES: NUMBER OF"ROOMS (BY STORY) : HOW-HEATED: T. /�/9fiE�P GAS: YES N0: /V� ke NUMBER OF SANITARIES: . // ///"" NUMBER OF APPROVED EGRESS DOORWAYS: REMARKS:- FEE RECEIVED: YESlz NO: i C4 (L The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF Massachusetts State Building Code,780 CMR SALEM Revised Mar 2011 Building Permit Application To Construct,Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: J Date p n e Building Official(Print Na a gnature Da SECTION I: SITE INFO TION 1.1 Property Address: 1.2 Assessors Map&Parcel Numbers L la Is this an accep ed street?yes x no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq m Frontage(it) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone?Check if yes[3 Municipal❑ On site disposal system ❑ �`� f SECTION 2: PROPERTY OWNERSHIP' rn.,, �p� 2.``lJ[ ��rTrd• \ Salem Nlk V�G Iv Name(Print) /I City,State,ZIP lCAA� Q �� �l`a QaL]� No.and Street Telephone Email Address l/ SECTION 3:DESCRIPTION OF PROPOSED WORK (check all that apply) New Construction t Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ AI[eration(s) ❑ Addition ❑ Demolition ❑ 1 Accessory Bldg. ❑ 1 Number of Units Other ❑ Specify: Brief Description of Proposed Work2: ', S'fQX p Dlrtai•DV n l-FatL Sour ,SySlp r1F �Y1 D 5 � SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1.Building $ iativ,.o0 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $30 ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire Soppression) $ Total All Fees:$ Check No. Check Amount: Cash Amount:_ 6.Total Project Cost: $ 31 1!�D. 00 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES r Supervisor License(CSL) VyP�1�QXl License Number Exp anon ate r S_y_, List CSL Type(see below) U ' t' Type Description SCL LY 1,1_S , A 1 A O 101 O� U Unres c ed(Buildin s u to 35,000 cu.ft. r"l _l R Restricted 1&2 Famil Dwelling CityITown,Sy�t ZIP M Maso (/ RC RoofingCovering WS Window and Siding ',�C.� SF Solid Fuel Burning Appliances lat3 l rVloLsolar� VIVt.u snp Lir. 1 Insulation Tele hone Email address Corn D Demolition 5.2 Registered Home Improvement Contractor(HIC) I\/I nzt 0k0.Y �y21op2Y L LC. HIC Registration Number Exxp-i`r`atio—n Date HIC Company Name or HICK egistrant Name t-1�3 1 et ADO hnaSOlGu�J V tvtvL}solar. No.and Street Email address C,Dyvt Provo uF S4(oo4 q$130530LOS Ci /Town,State,ZIP Tel hone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.¢ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes.......... No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize V IV IV_t Sfl I W to act on my behalf,in all matters relative to work authorized by this building permit application. �D(o. 2 2R-1D . Print wner's am (Electronic Signature) Date r' SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in th' p . tion is true and accurate to the best of my knowledge and understanding. v t a r a- �� Print O s r rized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.eov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of halfibaths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" �`� CERTIFICATE OF LIABILITY INSURANCE °A'�'12013 Y"' nrovzDl3 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHONE FAX DENVER,CO 10202-5534 e ali ac No Attn:Denver.cerbequest@marsh.com,Fax:212.948.4381 ADDRESS: INSURE $ AFFORDING COVERAGE NAICd 462738-STNDGAWUE-13-14 INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:National Union Fire Insurance Go of PA Vivinf Solar,Inc. 4931 N 300 W INSURER C:New Hampshire Insurance Company 23841 Provo,UT 84604 INSURER 0: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-00236BO30-06 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSR WVO POLICY NUMBER JMNyGcrYyyyIMMID LIMnS A GENERAL LUIBXITY 13PKGWE00274 11101/2013 11101/2014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY AMAG x 50,000 PREMISES(Ea occurrence) E CLAIMS-MADE M OCCUR - MED ExP(Any one person) $ 5,000 PFRSONAI RAM INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OPAGG $ 2,000,000 X POLICY PRO- LOCI I $ B AUTOMOBILE LIABILITY 9701087 11ro112013 111OW014 COMBINED SINGLE LIMIT 1,000,000 Ea accident) B % ANY AUTO 9701088 11101/2013 1%1/2014 BODILY INJURY(Per person) S ALL OWNED6AUTOS BODILY INJURY(Per accident) $ X HIRED AUTOS XNED PROPER DAMAGE $ S A UMBRELLA LIAB 13EFXWE00088 11/0112013 11ro1/2014 EACH OCCURRENCE $ 10,0M,000 X EXCESS Me AGGREGATE $ 10,000,000 LIED RETENTI It C WORKERS COMPENSATION 029342334; 029342335 11/01/2013 11/01/2014 % I WC STATU- OE 1,000,000 EMPLOYERS'LUUIWTYDRY LIM D ANY PROPRIETOR/PARTNEWEXECUTIVE YIN 029342336; 029342337 11/01/2013 11101/2014 1,000,000 OFFICERAAEMBER EXCLUDED? NIA E.L.EACH ACCIDENT E C (Mandatary In NH) 029342338 11/01/2013 11/01/2014 E.L.DISEASE-EA EMPLOYE $ 1,000,000 N yes,describe under 1 000 000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Enors&Omissions& 13PKGW00029 11101/2013 11/01/2014 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Attach ACORD 101,Additional Remarks Schedule,N more space Is required) he Certificate Holder and others as defined in the written agreement are included as additional insured where required by written contract with respect to General Liability.This insurance is primary and non. nbibutory over any existing insurance and limited to liability arising out of the operations of the named insured and where required by written centraci Waiver of subrogation is applicable where required by written ntracl with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEJIN 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERE Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe > X,(/�x. r-hr. IQrelsri ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD i Y Long Tess oitreet, owite I UU VIM Boston, MA 027I4-2017 www.Yn as's.go v1didt NVorkers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Vivint Solar Developer, LLC Address:4931 North 300 West City/State/Zip:Provo, UT 84604 Phone #:801-704-9389 Are you an employer? Check the appropriate box: Type of progect(regenired): 1.9 I am a employer with 10 4. I am a general contractor and I employees (full and/or part-time)." have hired the sub-contractors 6. ❑ New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. Remodeling ship and have no employees These sub-contractors have 8_ Demolition working for me in any capacity. employees and have workers' [No workers' comp. insurance comp. insurance.t 9. Building addition ` required.] 5. 0 We are a corporation and its ME] Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I LEI Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4), and we have no (3.❑ Other employees. [No workers' comp. insurance required.] 'Any applicant that checks box#I must also lilt out the section below showing their workers'compensation policy information. T Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such. Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. [f the sub-contractors have employees, they must provide their workers'comp.policy number. I am an employer that is providing wonders'compensatioA insurance for my employees. Below is the policy and job site information. insurance Company Name:New Hampshire Insurance Comany Policy# or Self-ins. Lic. #:029342228 Expiration Date:1,11I-,0`1-14 Job Site Address:a cc CTC QQ��\i City/State/Zip:�kJ�lm � Q�� Attach a copy of the workers' compe cation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required Linder Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to 11,500.00 and/or one-year imprisonment, as well as civil penalties in the form of STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do Hereby Certi ander.thp paieT and penalties of perjupy that the information provided above is true and COPPCC't; / y�e i . Siarlature: %"/ �� i/ � � Date (a Phone#: 801-704-9389 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/I.ieense # Issuing Authority (circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: Office of Consumer Affairs ftnd Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card. Mark reason for change. sCn t 0 20M-05111 Address Renewal Employment E Lost Card Cl�ze�amvmwazure«rC�i,a��mtrc�tunn/10 gRegistration: ice of Consumer Affairs&Business Regulation License or registration valid for individul use only MEIMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation . 170848 Type: 10 Park Plaza-Suite 5170 Expiration: 1/5/2016 Supplement Gard Boston,MA 02116 VIVINT SOLAR DEVELOPER LLC. JAMES SHERMAN 4931 NORTH 300 WEST � _— PROVO, UT 84604 Undersecretary Not valid without signature -- t Massachusetts -Department of Public Safety Board of Building Regulations and Standards - Construction Supemsur License: CS-045254 t JAMES R SHERMAN d 81 MAIN ST SAUGUS MA 01406 , Expiration Commissioner 08/28/2014 2781 Fries Mill Road,Williamstown,NJ 08094 Tel: 856.770.4473; rdcipolla@verizon.net Vivint Solar February 26, 2014 24 Normac Road Woburn MA, 01801 Attn: Mr. Paul Greene, Operations Manager Re: Structural Assessment Report for Roof Mounted Photovoltaic (Solar)Panel Installations—Lavoie Residence, 7 Cottage Street, Salem,MA AR#3552330 ` Dear Paul: We are providing you with this structural assessment report of Vivint Solar's photovoltaic (solar) roof installations to be completed at the above referenced dwelling. The assessment criteria are based upon Vivint's recent dwelling site visit including roof framing photographs and field notes. We have also reviewed Vivint's PV Solar Permit Submittal, calculations, installation layouts and notes, PV 1.0 "Site Plan",PV 2.0 "Roof Plan", and PV 3.0, "Mounting Details". All were supplied for information on the proposed solar panels installation on the dwelling's roof framing members for our assessment summary. The dwelling is timber framed of older construction age with an"A"framed main roof, 8'- 2" +/- high, built from nominal 2" x 6" dimensional lumber joists at 16" o/c, typical. There is an attached "A" framed garage roof assumed to be similarly framed. The maximum roof joist span length is 15' — 6" +/- excluding reductions for collar ties supports. Two layers of roof shingles are assumed. Materials are assumed as minimum Hem-Fir #2 grade, conservatively (low allowable stresses), with standard construction components (better grade lumber may have been used). 2" x 8" collar ties are installed at 32" +/- o/c spacing on the joists, set 24" +/- below the top of the 2" x 8" ridge beam in the main "A" roofs'/attic's full length, in panel installations areas, for adequate roof reinforcing. There are no other roof joists or ridge beam supports, the full length of roof, down to framing below. The main attic and roof framing were mostly accessible by access panels at the site inspection and evaluation, so a complete assessment and confirmation of framing spacing, sizes and condition was able to be performed for this roof. The garage roof received a partial assessment No architectural drawings were available at the time of this report preparation. Refer to plans and documents prepared by Vivint for dwelling dimensions, locations and sizes of solar panel units. The roof framing members were reviewed and checked for their capacity of new loadings. A. CAPACITY OF EXISTING ROOF TO SUPPORT PROPOSED SOLAR PANELS: 1. Our assessment included using the proposed solar panels dead load that were given to us in the ZEP calculation sheets and the live and dead loads described below. Our review of the roof information shows that there are no visible undulations or unevenness, indicating that the roof framing members are not visibly overstressed or weakened by past heavy snow loads. r Mr. Paul Greene February 26, 2014 Page 2 2. Given the dwelling's roof construction and condition, the existing roof joists' load carrying capacity will be able to carry the added dead and redistributed live loads from the new solar panels if installed correctly. The dwelling's roof members will also redistribute the snow live loads,and additional solar panels dead load to the adjacent framing members. These additional loads should not produce stresses beyond the allowable stress range for roof framing members assumed as Hem-Fir 42 materials. Considering the low roof slopes, array sizes; full/limited access to confirm roof joists' size, spacing, condition; and collar ties, the panel supports shall be set/attached to every third joist for lateral installations over joists. No panel supports ap cing shall be greater than three(3)roof joist spaces, or 48" o/c,to be shown in the PV 2.0 Roof Layout plan(s). Note—Layout Array Drawings#1, #2  submitted for review, shows every four joists, 64" o/c maximum panel support spacing, and which need to be revised to the above spacing. The panel supports shall be installed in staggered patterns to ensure the proper load distribution, and with no more than three supports placed on any single roof joist, except at ends of layouts. After revising,these layouts can be used for permit submittals and installations. All panels shall be installed as shown on the layout plans with 48" o/c maximum support spacing, or three joist spaces and staggered, to be shown in the final revised PV 2.0 Roof Layout plan(s), as stated above. Framing member sizes, spacing and condition must be properly verified by Vivint's installers, prior to any installations. Send any differing information to this engineer for review and approval, prior to continuing with any installations. 3. This assessment meets current Massachusetts Building Code, 8t'Edition—Residential —Amendments to International Residential Code, (IRC), 2009 Edition, for one and two family dwellings. B. SOLAR PANEL ATTACHMENT TO ROOF STRUCTURE: 1. The solar panels shall be mounted in accordance with the latest"ZEP Company's Code Compliant Installation Manual"found on the ZEP website and not included herein. No additional reinforcing requirements are required for these installations. However, if during solar panel installations, the roof framing members feel unstable, or show interior or exterior evidence of minor or excessive movement, then this engineer should be notified as soon as possible prior to proceeding with installations. 2. Vivint should notify the homeowners that long term build-up of accumulated snow in the event of extreme snowfall conditions, may produce some roof deflections. These deflections will be temporary in nature and will not affect the roof s structural integrity. The solar panels do not need to be cleared of such accumulated snow. C. WIND UPLIFT LOAD: 1. Refer to attached ZEP calculation sheet for ASCEISEI 7-10 Minimum Design Loads Mr. Paul Greene February 26, 2014 Page 3 For Buildings and Other Structures, for wind speed at this location of 100 miles per hour* for Exposure Category `B", and 19 degree roof slopes on the dwelling's roof areas. Ground snow load is 40 p.s.f.* for Exposure `B",Zone 1 (per ASCE/SE17- 10) of the roof's interior portion, and effective wind speed of 100 mph*, uplift is shown. 2. Total area subject to wind uplift is calculated for the Interior,Edge and Corner Zones. A maximum and user selected support(foot) spacing is shown for each location zone. D. PANEL ANCHORAGES: 1. Maximum allowable pullout per lag screw= 235 #/inch from National Design Standards (NDS)timber construction specifications for Hem-Fir-North lumber (assumed). Using 4 lag screws, the pullout value is less than 235 #/inch of screw thread and OK. Considering the variable factors for the existing roof framing members, and installation tolerances, use a 2 '/2"threaded depth with a minimum 5/16"lag screw per attachment points in roof joists ("rafters") components for panel anchor mounts. This should give a sufficient factor of safety. E. LIVE, DEAD AND SNOW LOADS: 1. Live load=40 p.s.f ground snow load; 10 p.s.f. attic storage (trusses only) Dead Load= 10 p.s.f.-roofing/framing; 5 p.s.f - panels, mounting hardware Total Live Load=40 p.s.f; Total Dead Load= 15 p.s.f. 2. These values are within acceptable limits of recognized industry standards for similar structures. The roof members will be able to sustain the solar panel attachments without damage, if installed in a workmanship like manner according to the above criteria. We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. This report covers this dwelling's assessment for only the areas for solar panel installations that were made according to generally recognized structural analysis standards and procedures. The normal structural engineering industry standard of care utilized for this type of work was used during this report preparation. The assessments and recommendations in this report were reviewed to ensure a proper level of quality and uniformity. This report adheres to accepted State and National practices for current building code standards and can be used for construction purposes. If you have any questions or require further information, please do not hesitate to contact me. Respect y submitte Russell D. ipol ,R st d Structural Engineer, Owner Sao Mass. License No. EN-47478-S �� RUSSELL D. yu CIPOLLA > STRUCTURAL c * or as specified locally per the State Board of Bldg. Regs. and Stds., whichever go No.47470 RDC/rdc 90 9FGISTS q, `ASS/ONALEe��'\ 7 Cottage St, Salem MA c �N. LO�Z U-Z N�"o 40'OF PVC CONDUIT �2 O FROM JUNCTION BOX TO ELEC PANEL .O T Q PV SYSTEM SIZE: J 6.25 kW DC JUNCTION BOX ATTACHED TO ARRAY USING ZEP ZS-GAB TO KEEP JUNCTION BOX OFF ROOF 0 INTERCONNECTION POINT, d LOCKABLE DISCONNECT SWITCH, n ANSI METER LOCATION, - &UTILITY METERERLOCATION TION ry •`Cy a am o K¢ (25)Tnna Solar TSM-250 PA05.16 MODULES WITH A m 4 Enohase M21 S60-21-1--S2z ZC MICRO,INVERTER m C MOUNTED ON THE BACK OF EACH MODULE j E Z w wrc w > w w 2 m Z F F Q N w Q K SHEET NAME: Lu Z ~ J d SHEET NUMBER' PV SYSTEM SITE PLAN o SCALE: 3/32"= V-0" a a m N O 0 0 N A 00 �< T OO < 0A z m� [n II �n 0p AAA OC! 00 C 0y y� M 8�m ;o o� N m w � m u � � o 0 O m� �m n y HO r m D m Z >i INSTALLER VIVINTSOLAR Lavoie Residence mm ROOF mmINSTALLER NUMBER:1.877404.4129 �odu�� solar 7Cettage St PV 2.� p MA LICENSE:MAHIC 170848 • Salem,MA-- PLAN DRAWN BY:mk AR 3552330 Last Modified:21242014 UTILITY ACCOUNT NUMBER:5068501016 U C N o MOUNTING PV3.0 DETAIL m A16'61Ba1'STAINLE66 rV EZ LEVE4IZ&C.AI STEEL M.B.;TORQUE=1611 HIM. U_Z N "o COMP MO V WASHER PACKAGED •O Q WATERPROOFING BE WITH COMP MOUNT PV MODULE,TYP.MOUNT AS NEEDED TO RAFTERS OF COMP. (O SHINGLE ROOF,PARALLEL J j WITH PLANE OF ROOF PV ARRAY TYP. ELEVATION STAINLESS TAINL SS MINIMUM E 6TAINLE666TEEL LAG SCREW Lv TORQUE=1]SZ flAb. NOT TO SCALE 0 V/ • (LEVELING FOOT ON COMP MOUNT PERMITTED LEVELING NOT TO SCALE FOOT SPACING •0 N •Q LEVELING FOOT(ZSLFB) J IIII III III FRVAING BELOW SHOIII W N OASHEOFOROARITZEE COMPATIBLE ATIBLE PV MODULE HYBRID I In II NTEI RLODH II CPNTLEVER= N FR ED5"IK<- nEDWK Q OIRL IAL E PACING B6pSEE CODE COMPLPEMTERBOALLOWABLE SPACNG PHOTOVOLTAIC MODULE > Z N <""SHEET TEOK RLocRIzle) HY9RIDNR NAME: LEVELING FOOT(Z FBI ROOF FRAMING ~�IW"Ws` m LEVELING FOOT(ZSLFB) I23E Z J ow INTERLOCK(ZB,LB) PERMITTEDLEVELING FOOT SPACING IPV SYSTEM MOUNT DETAIL SHEET❑ NUMBER' (MODULES IN PORTRAIT/LANDSCAPE SCALE:3/8°_1•-0• ch NOT TO SCALE a Inverter Ratings(Guide Section 4) Inverter Mekewerew Enphase M215-60,21-b5211-W MODULE DETAIL Max DC Von Rem, 45 vela O Conduit and Conductor Schedule Max Pdwerigill 215 Wens Tat Des none Wire Gouge eofeoneucres Condugryve Coneun slee Nomma ACVbxmge NO Volts 1 scone,engage pole-TXWN-2 4AWG 4 N.-Free.. fil-Free ear Tons Solar TSM-250 PA05.76 Max AC Cunent 09 PmOe 1 co eere Coppm GmundcN.GEO) fiPWG 1 MP-Freees hwN Freeeir L) uh SOLAR MODULE Mee oc.D Rating 20 Ampe 2 THwN-2 1g AwG s we o'-1. be a Max Number of Penelocceit tT 2 THWW2-Gwnd AWG 1 PVC 0-1. ^, J TXWN-E AWG I PVC e'-1' V N J TH.2-Gani BAWG 1 NL 0'-1' NOTES FOR INVERTER CIRCUITS(Guide Section 8 and 9), to 1J IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS PV Module Ratings@ STC(Guide Section 5) �rf�. SWITCH MEET THE REQUIREMENTS? a z Emphatic M215-60.2LL-S2x-2C YES NO XNA Model MekelModel Tnna Solar TSM-250 PA05.18 ��yF Max Power-Polat Current(imp) 7.89 Amps 2 MICRO-INVERTER AT 2J IF GENERATION METER REQUIRED,DCES THIS METER Max Power-Point Voltage(Val 30A Volta 0'�.7p EACH MODULE,ATTACHED SOCKET MEET THE REQUIREMENTS? U WITH ZEP HARDWARE oven-Ciwit voltage 37Z Volta YES NO XNA Shon-C'vcuit Current Ism 8.37 Amps 0 ><> 3.)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS Max Saves Fuse s0CPm 15 Amps F BASED ON MAX CURRENT ON NEC 690.53 SIGN OR CCPD Nominal Maximum Power at STC lProso 240 Watts RATING AT DISCONNECT. Maximum System Voltage 1000(IECy600(UL) j 4L SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Vop Temperature CoaRcient -0.32 %'C #6 BARE CU GROUND TO INVERTER OCPD AMPERE RATING(See Guide Season 9), (GROUNDING MODULE v 5.)TO1ALOF 2 INVERTER OCPO(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WRING(Guide Section 6 and 8 and Appendix Dl: S INVERTER) PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY 1 WITH I2D%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean extreme NEC69064(13)(2)(a)? XYES NO dry bulb temperature for ASHRAE location most similar to installation location: -19-C MICROINVERTER CONNECTION Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb O TO ENGAGE TRUNK CABLE temperature for ASHRAE location most similar to installation locabon: 39-C Sign for inverter DICED and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47-C in the 0 United Slates(Palm Springs,CA is 44.PC).For less than 9 current-carl conductors Solar PV System AC Point of Connection in mcf.mounted sunlit conduit at least 0.5-above met and using the outdoor design AD Output Current 22500000 I Amps tempereure of 47-C or less(all of United States). v Nominal AC voltage ..I Volts a.)12 AWG,90-C conductors are generally acceptable for modules with Ise of 7.68 Amps par less when premb ed by 12-Amp or smaller fuse. THIS PANEL FED BY MULTIPLE SOURCES v (UTILITY AND SOLAR) b.)10 AWG,90-C conductors are generally acceptable for modules went Ise of 9.6 Amps E" or less when probeactedb a1SAm or smaller fuse. re a m PV CIRCUIT 1: 16 MODULESIPARALLEL pre 0 POINT OF DELIVERY be 2 N AND INTERCONNECTION c m o m e Or- n J` • • • Js Js F W (J Q 2_ be Q -- VISIBLE/LOCKABLE M > i w E I COMBINER SREC/ANSI 'KNIFFA/C PV CIRCUIT 2: 9 MODULESIPARALLEL 'I i PANEL METER DISCONNECT al LU z E 1.0 200� p~1 N Q Q e e Q O 20A ? ? � o I SHEET NAME: ✓` • • • N N 1 30A UJ ____ ___ _ _______ __ ___ ______ _ _ _ Z ____ ____ _____ _______ VisionMetedng Siemens 240V/200A Q 2 3 V2S-26 3 #LNF222R 3 1 LOAD-CENTER p 60A/240V JUNCTION BOX SHEET E 1.0 WITH IRREVERSIBLE E 1.0 E 1,0 E 1.0 UNFUSED E 1.0 NUMBER: GROUND SPLICE NEMA3 O NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY T_ 'ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR W OMP.SHINGLE V •�mQm I O m z o THIS ROOF SECTION NOT USED.USAGE- WAS REACHED WITH OTHER SECTIONS. �,m'.,{! '* �' { �� ��� 6MOWlE5 AT 100125 SUN HOURS � c 'Yy d d fr �a. '" vinance'.6.91 Feet �r THIS ROOF SECTION NOT USED.USAGE a 5�� �' WAS REACHED WITH OTHER SECTIONS. • I A {� _�� I 1 •0 8 MODULES AT 1041.33 SUN HOURS � �• k �h y:.,•re 1 y .., o ' � �a > i w E K K N > Z m a Z a a3 N Q y USAGE CONSTRAINT SHEET NAME: Z U C7 — C7 W 0 O SHEET NUMBER: C) N Q. Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Gerard Lavoie Project Address: 7 Cottage St,Salem MA A.System Description: The array consists of a 6.25 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(25) 250-watt modules and(25)215-watt micro-inverters,mounted on the back of each PV module_The array includes(2)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Zep Solar. B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Zep Solar b.Product Name: ZS Comp c.Total Weight of PV Modules and mounting hardware: 1075 Ibs d.Total number of attachment points: 34 e.Weight per attachment point: 31.61 Ibs/square foot f Maximum spacing between attachment points: * See attached Zep engineering talcs g.Total surface area of PV array: 440.25 square feet h. Array pounds per square foot: 2.44 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (16)modules,(22)attachments 31.27 pounds per square foot -Roof section 2: (9)modules,(12)attachments 32.25 pounds per square foot vivint. solar 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 250-PA05.18 25 modules Module Specs Pmax-nominal maximum power at STC - 250 watts Vmp-rated voltage at maximum power - 30.3 volts Voc-rated open-circuit voltage - 37.6 volts Imp-rated current at maximum power - 8.27 amps Ise-rate short circuit current - 8.85 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-21.L-S22 25 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 1. Input Data (DC in) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters I Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 16 modules/inverters (20)amp breaker PV circuit 2 - 9 modules/inverters (15)amp breaker vivint. s©Iar D. Electrical Calculations 1. PV Circuit current PV circuit nominal current 14.4 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(B) PV circuit continuous current rating 18 amps 2.Cvercurrent protection device rating PV circuit continuous current rating 18 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amo AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity,derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NGC Table 310.15(B)(3)(e) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Table 310.15(B)(2)(a) Adjusted PV circuit continuous current 25.3 amps c. PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 80% 2011 NEC Table 310.15(B)(3)(a) Final Adjusted PV circuit continuous current 31.6 amps Total derated ampacity for PV circuit 31.6 amps Conductors(tag2 on 1-line)must be rated for a minimum of 31.6 amps THWN-2(90°C)#10AWG conductor is rated for 40 amps (Use#10AWG or larger) 2011 NEC Table 310.15(B)(16) 4.Voltage drop(keep below 3%total) 2 parts: 1.Voltage drop across longest PV circuit micro-inverters (from modules to j-box) 2. Voltage drop across AC conductors(from j-box to point of interconnection) 1.\hrco-inverter voltage drop: 0.39% The largest number of micro-inverters in a row in the entire array is 9 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.39%. 2.AC conductor voltage drop: =I x R x D (+240 x 100 to convert to percent) = (Nominal current of largest circuit)x(Resistance of#10AWG copper)x(Total wire run) = (Circuit 1 nominal current is 14.4 amps)x(0.0012652)x(120�*(240 volts)x(100) 0.9% Total system voltage drop: 1.29% vivint. scalar 2/25t2014 3552330-Zepulator 0. ZepSolar Engineering Calculations 3552330 Name:Gerard Lavoie Street Address:7 Cottage St. Email: Suite/PQ#: Phone: City,State,Zip:Salem, Massachusetts Country:United States System Details Module Manufacturer Trina Solar Mounting System Zap Solar PV Module TSM-250-PA05.18 Manufacturer Quantity of PV Modules 10 Mounting System Type ZS Comp Array Size (W) 2.500 Roof type Composition Shingle Attachment Type Comp Mount,Type C Module-level Enphase Energy-M215-Z electronics http:/A a 2epulator.con-Vprojects/46561/sumna Vwgineering_print 1/4 2/2512014 3552330-Zepulator Engineering Calculations Design Variables Description(Symbol) Value Unit Module Orientation Landscape Module Weight 44.8 Ibs Average Roof Height(h) 25.0 ft Least Horizontal Dimension(Ihd) 20.0 ft Edge and Corner Dimension"a" 3.0 ft Roof Slope(0) 19.0 deg Rafterfrruss spacing 16.0 in Rafter/Truss dimension Min.nominal framing member depth of 4" Basic Wind Speed(V) 100 mph E)posure Category B Ground Snow Load(Pg) 40 psf Importance Factor(1) 1.0 Topographic Factor(Kit) 1.0 Thermal Factor for Snow Load(Ct) 1.2 F)yosure Factor for Snow Load (Ce) 0.9 Effective Wind Area 10 ft2 Snow Load Calculations (Using calculation procedure of ASCE 7-05 Section 7) Description(Symbol) Interior Edge Corner Unit Flat Roof Snow Load(Pt) 30.2 30.2 30.2 psf Slope Factor(Ce) 0.9 0.9 0.9 Roof Snow Load 28.0 28.0 28.0 psf Wind Pressure Calculations (Using simplified procedure of ASCE 7-05 Section 6.4) Description(Symbol) Interior Edge Corner Unit Net Design Wind Pressure uplift(Pnet3o_up) -16.5 -28.7 -42.4 psf Net Design Wind Pressure downforce(Pnet3o down) 10.4 10.4 10.4 psf http:ltw .zepulator.conVprojmts/46561/summer engineering_print 214 2/2512014 3552330-Zepulator Adjustment Factor for Height and Exposure Category(A) 1.0 1.0 1.0 Net Design Wind Pressure uplift(W„p) -16.5 -28.7 -42.4 psf Net Design Wind Pressure downforce(Wdmn) 10.4 10.4 10.4 psf ASD Load Combinations (Using calculation procedure of ASCE 7-05 Section 2.4) Description(Symbol) Interior Edge Corner Unit Dead Load(D) 2.5 2.5 2.5 psf Snow Load(S) 26.5 26.5 26.5 psf Load Combination 1 ((D+075'S)'cos(0)+0.75'Wdmn) 29.0 29.0 29.0 psf Load Combination 2(D-cos(0)+Wd.w ) 12.8 12.8 12.8 psf Load Combination 3((D+S)'cos(0)) 27.5 27.5 27.5 psf Uplift Design Load(0.6'D'cos(0)+WuP) -15.1 -27.3 -41.0 psi Maximum Absolute Design Load(Pabs) 29.0 29.0 41.0 psf Spacing Calculations Description(Symbol) Interior Edge Corner Unit Max allowable spacing between attachments 72.0 72.0 59.0 in User selected spacing between attachments given a rafter/truss spacing of 16.0 in 64.0 64.0 48.0 in Max cantilever from attachments to perimeter of PV array 24.0 24.0 19.0 in Distributed Weight and Weight per Attachment Point Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)) Description(Symbol) Value Unit Weight of Modules 448.0 Ibs Weight of Mounting System 41.93 Ibs Total System Weight - 489.93 Ibs Total Array Area 176.13 ft2 Distributed Weight 2.78 psf Total Number of Attachments 18 Weight per Attachment Point 27.22 psf http:/Mn ..zepulator.coni/projects/46561/suarnary'engineeringjrint 3/4 2/25/2014 3552330-Zepulator http:/AmNw2epulator.coriVprojects/46561/sunwwVenginmring_print 4/4 2/25/2014 3552330 rl port-Zepulator ZepSolar Engineering Calculations 3552330 r1 port Name:Gerard Lavoie Street Address:7 Cottage St. Email: SuitelPO#: Phone: City,State,Zip:Salem,Massachusetts Country:United States System Details Module Manufacturer Trina Solar Mounting System Zap Solar PV Module TSM-250-PA05.18 Manufacturer Quantity of PV Modules 6 Mounting System Type ZS Comp Array Size (kW) 1.500 Roof type Composition Shingle Attachment Type Comp Mount,Type C Module-level Enphase Energy-M215-Z electronics http:/Mw ..zepulator.cc"proj is/46562/summerylengineeringyrint 1/4 2/25/2014 3552330 rl port-Zepulator Engineering Calculations Design Variables Description (Symbol) Value Unit Module Orientation Portrait Module Weight 44.8 Ibs Average Roof Height(h) 25.0 ft Least Horizontal Dimension(Ihd) 20.0 it Edge and Corner Dimension"a" 3.0 it Roof Slope(0) 19.0 deg Rafter/Truss spacing 16.0 in Rafter/Truss dimension Min.nominal framing member depth of 4" Basic Wind Speed(V) 100 mph E)posure Category B Ground Snow Load(Pg) 40 psf Importance Factor(1) 1.0 Topographic Factor(Kit) 1.0 Thermal Factor for Snow Load(Ct) 1.2 E)posure Factor for Snow Load(Ce) 0.9 Effective Wind Area 10 ft2 Snow Load Calculations (Using calculation procedure of ASCE 7-05 Section 7) Description(Symbol) Interior Edge Corner Unit Flat Roof Snow Load(Pf) 30.2 30.2 30.2 psf Slope Factor(Cs) 0.9 0.9 0.9 Roof Snow Load 28.0 28.0 28.0 psf Wind Pressure Calculations (Using simplified procedure of ASCE 7-05 Section 6.4) Description(Symbol) Interior Edge Corner Unit Net Design Wind Pressure uplift(Pnet30_up) -16.5 -28.7 -42.4 psf Net Design Wind Pressure downforce(Pnet30 down) 10.4 10.4 10.4 psf Lhttp://w .zepulata.com/projects/46562/summarVmgineering_print 214 2/252014 3552330 ri port-Zepulator Adjustment Factor for Height and Exposure Category(A) 1.0 1.0 1.0 Net Design Wind Pressure uplift(Wup) -16.5 -28.7 -42.4 psf Net Design Wind Pressure downforce(W&o n) 10.4 10.4 10.4 psf ASD Load Combinations (Using calculation procedure of ASCE 7-05 Section 2.4) Description(Symbol) Interior Edge Corner Unit Dead Load(D) 2.5 2.5 2.5 psi Snow Load(S) 26.5 26.5 26.5 psf Load Combination 1 ((D+0.75*S)*cos(@)+0.75*Wdmn) 29.0 29.0 29.0 psf Load Combination 2(D*cos(@)+Wdo,,,,,,) 12.8 12.8 12.8 psf Load Combination 3((D+S)*cos(@)) 27.5 27.5 27.5 psf Uplift Design Load(0.6*D*cos(@)+Wup) -15.1 -27.3 -41.0 psf Maximum Absolute Design Load(Pabs) 29.0 29.0 41.0 psf Spacing Calculations Description(Symbol) Interior Edge Corner Unit Max allowable spacing between attachments 67.0 53.0 35.0 in User selected spacing between attachments given a rafter/truss spacing of 16.0 in 64.0 48.0 32.0 in Max cantilever from attachments to perimeter of PV array 22.0 17.0 11.0 in Distributed Weight and Weight per Attachment Point Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)) Description(Symbol) - Value Unit Weight of Modules 268.8 Ibs Weight of Mounting System 25.13 Ibs Total System Weight 293.93 Ibs Total Array Area 105.68 ft2 Distributed Weight 2.78 psf Total Number of Attachments 10 Weight per Attachment Point 29.39 psf http:/Av zepulator.corrJprojects/46562Isummart/engineeringyrint 314 2/25/2014 35523W r1 part-Zepulator http:/Av ..zepulator.con✓projects/46562/su�rVengineering_print 4/4 2/25/2014 3552330 r2-Zepulatcr ZepSolar Engineering Calculations 3552330 r2 Name:Gerard Lavoie Street Address:7 Cottage St. Email: Suite/PO#: Phone: City,State,Zip:Salem,Massachusetts Country:United States System Details Module Manufacturer Trina Solar Mounting System Zap Solar PV Module TSM-250-PA05.18 Manufacturer Quantity of PV Modules 9 Mounting System Type ZS Comp Array Size (kith 2.250 Roof type Composition Shingle Attachment Type Comp Mount,Type C Module-level Enphase Energy-M215-Z electronics http:/A v .zepulator.caNpro mts/46563/sun mwVengince ing_jxint 1/4 2125/2014 3552330 r2-2epulator Engineering Calculations Design Variables Description(Symbol) Value Unit Module Orientation Landscape Module Weight 44.8 Ibs Average Roof Height(h) 25.0 ft Least Horizontal Dimension(Ihd) 20.0 ft Edge and Corner Dimension"a" 3.0 ft Roof Slope(0) 19.0 deg Rafter/Truss spacing 16.0 in Rafter(rruss dimension Min.nominal framing member depth of 4" Basic Wind Speed (V) 100 mph Exposure Category B Ground Snow Load (Pg) 40 psf Importance Factor(I) 1.0 Topographic Factor(Kit) 1.0 Thermal Factor for Snow Load(Ct) 1.2 Exposure Factor for Snow Load(Ce) 0.9 Effective Wind Area 10 ft2 Snow Load Calculations (Using calculation procedure of ASCE 7-05 Section 7) Description(Symbol) Interior Edge Corner Unit Flat Roof Snow Load(Pt) 30.2 30.2 30.2 psf Slope Factor(Cs) 0.9 0.9 0.9 Roof Snow Load 28.0 28.0 28.0 psf Wind Pressure Calculations (Using simplified procedure of ASCE 7-05 Section 6.4) Description(Symbol) Interior Edge Corner Unit Net Design Wind Pressure uplift(Pnet30_up) -16.5 -28.7 -42.4 psf Net Design Wind Pressure downforce(PneQ0 down) 10.4 10.4 10.4 psf http:/Am .zepulata.con✓projects/46563/summa Vwgineering_pint 214 i 2125/2014 3552330 r2-2epulator Adjustment Factor for Height and Exposure Category(A) 1.0 1.0 1.0 Net Design Wind Pressure uplift(Wup) -16.5 -28.7 -42.4 psf Net Design Wind Pressure downforce(Wdown) 10.4 10.4 10.4 psf ASD Load Combinations (Using calculation procedure of ASCE 7-05 Section 2.41 Description(Symbol) Interior Edge Corner Unit Dead Load(D) 2.5 2.5 2.5 psf Snow Load(S) 26.5 26.5 26.5 psf Load Combination 1 ((D+0.75"S)'cos(6)+0.75'Wdmn) 29.0 29.0 29.0 psf Load Combination 2(D'cos(8)+Wdown) 12.8 12.8 12.8 psf Load Combination 3((D+S)`cos(6)) 27.5 27.5 27.5 lost Uplift Design Load(0.6"D'cos(6)+Wup) -15.1 -27.3 -41.0 psf Maximum Absolute Design Load(Pabs) 29.0 29.0 41.0 psf Spacing Calculations Description (Symbol) Interior Edge Corner Unit Max allowable spacing between attachments 72.0 72.0 59.0 in User selected spacing between attachments given a rafter/truss spacing of 16.0 in 64.0 64.0 48.0 in Max cantilever from attachments to perimeter of PV array 24.0 24.0 19.0 in Distributed Weight and Weight per Attachment Point Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)) Description(Symbol) Value Unit Weight of Modules 403.2 Ibs Weight of Mounting System 35.8 Ibs Total System Weight 439.0 Ibs Total Array Area 158.52 ft2 Distributed Weight 2.77 psf Total Number of Attachments 16 Weight per Attachment Point 27.44 psf http:/hw.w2epulator.caWprojects/46563/sunwayengineerirg_jxint 314 2/25/2014 3552330 r2-Zepulator http:/A+ ..zepulatu.conVprojmis/46%NsurrmiarV gineering_print 414.