Loading...
Owens_Corning Fiberglass SpecsECOTOUCH® PINK® FIBERGLAS™ INSULATION™ Data Sheet | EcoTouch ® Pink® Fiberglas™ Insulation | June 2020 Description Owens Corning ® EcoTouch ® PINK® Fiberglas™ Insulation with PureFiber® Technology is a preformed, flexible blanket insulation. It is produced in R-values from 11 to 49, with thicknesses ranging from 3 1/2 inches to 14 inches. It is available unfaced, or faced with either a kraft or foil vapor retarder. Features •Excellent thermal control •Effective acoustical control •Long term performance and will not settle nor slump within wall cavities •With less dust than other fiberglass products, EcoTouch ® PINK® Fiberglas™ insulation has excellent stiffness and recovery characteristics1 •Compression packaging from Owens Corning speeds job site handling and installation 1. According to 2010 clinical trial conducted in Toronto, Canada by Ducker Worldwide on behalf of Owens Corning Insulation Systems, LLC. Applications •Wood-framed wall, floor and roof/ceiling cavity wall assemblies •Metal-framed wall and floor cavity wall assemblies •Furring strips installed on the interior surface of basement walls •Interior surfaces of basement and unvented crawl space foundation walls Standards, Codes Compliance •Manufactured in compliance with ASTM C 665 •Federal Specification HH-I-521F has been canceled and is replaced by ASTM C 665 •Classified non-combustible when tested in accordance with ASTM E 136 •Unfaced EcoTouch® PINK® Fiberglas™ insulation is acceptable for use in ICC building construction types I through V; kraft and foil faced EcoTouch® PINK® Fiberglas™ insulation are acceptable for use in ICC building construction types III, IV and V •Certified to meet California Code of Regulations, Title 24, Chapter 12-13, Article 3, “Standards for Insulating Material” Physical Properties PROPERTY (UNIT)TEST VALUE Thermal Resistance ASTM C518 See “Availability” table for R-values Surface Burning Characteristics2 (flame spread / smoke developed) Unfaced Kraft faced Foil faced ASTM E 84 / UL 723 25 / 50 NR / NR 75 / 150 Critical Radiant Flux (W/cm2)ASTM E970 >0.12 Water Vapor Permeance (perms) Kraft faced Foil faced ASTM E96 1.0 0.5 Water Vapor Sorption (by weight)ASTM C1104 <5% Odor Emission ASTM C1304 Pass Corrosion Resistance ASTM C665, part 13.8 Pass Fungi Resistance ASTM C1338 Pass 2. The surface burning characteristics of EcoTouch® Insulation were derived from products tested in accordance with ASTM E84. This standard is used solely to measure and describe properties of products in response to heat and flame under controlled laboratory conditions, and should not be used to describe or approve the fire hazard of materials under actual fire conditions. However, the results of these tests may be used as elements of a fire risk assessment that takes into account all of the factors pertinent to an assessment of the fire hazard of a particular end use. Values are reported to the nearest five rating. Availability WIDTH LENGTH THICKNESS R-VALUE Metal Frame Construction 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 3 1/2" (89mm)11 16" (406mm) 24" (609mm) 48" (1,219mm) 96" (2,438mm) 3 1/2" (89mm)13 16" (406mm) 24" (609mm) 96" (2,438mm) 3 1/2" (89mm)15 16" (406mm) 24” (609mm) 48" (1,219mm) 96" (2,438mm) 6 1/4" (159mm)19 16" (406mm) 24" (609mm) 96" (2,438mm) 6" (152mm)21 24” (609mm) 48” (1,219mm) 6 3/4" (171mm)22 16” (406mm) 24” (609mm) 96” (2,438mm) 8" (203mm)25 16” (406mm) 24” (609mm) 48” (1,219mm) 9 1/2” (241mm)30 Wood Frame Construction Walls 11" (406mm) 93" (2,362mm) 105" (2,667mm) 3 1/2" (89mm)11 11" (406mm) 93" (2,362mm) 3 1/2" (89mm)13 11" (406mm) 105" (2,667mm) 3 1/2" (89mm)15* 11" (406mm) 93" (2,362mm) 6 1/4" (159mm)19** 12" (406mm) 48" (1,219mm) 9 1/2" (241mm)30* 15" (381mm) 23" (584mm) 48" (1,219mm) 93" (2,362mm) 3 1/2" (89mm)11 15" (381mm) 23" (584mm) 48" (1,219mm) 93" (2,362mm) 3 1/2" (89mm)13 15" (381mm) 23" (584mm) 93" (2,362mm) 3 1/2" (89mm)15 15" (381mm) 19 1/4"23" (584mm) 48" (1,219mm) 93" (2,362mm) 6 1/4" (159mm)19** 15" (381mm) 23" (584mm) 93" (2,362mm) 5 1/2" (139mm)20 15" (381mm) 23" (584mm) 93" (2,362mm) 5 1/2" (139mm)21 15" (381mm) 23" (584mm) 105" (2,667mm) 5 1/2" (139mm)21 23" (381mm) 23" (584mm) 93" (2,362mm) 5 1/2" (139mm)21 Floor/ Ceiling 15" (381mm) 19 1/4″23" (584mm) 48" (1,219mm) 93" (2,362mm) 6 1/4" (159mm)19 15" (381mm) 23" (584mm) 48" (1,219mm) 6 3/4" (171mm)22 15" (381mm) 23" (584mm) 48" (1,219mm) 8" (203mm)25 15 1/2" (394mm) 23 3/4" (603mm) 48" (1,219mm) 8 1/4" (209mm)30C 16" (406mm) 19 1/4"24" (609mm) 48" (1,219mm) 9 1/2" (241mm)30 15 1/2" (394mm) 23 3/4" (603mm) 48" (1,219mm) 10 1/4" (260mm)38C 16" (406mm) 24" (609mm) 48" (1,219mm) 12" (305mm)38 16" (406mm) 24" (609mm) 48" (1,219mm) 14" (356mm)49 *Made to order product **Delivers R18 value when installed in 5.5" deep cavity. Disclaimer of Liability Technical information contained herein is furnished without charge or obligation and is given and accepted at recipient’s sole risk. Because conditions of use may vary and are beyond our control, Owens Corning makes no representation about, and is not responsible or liable for the accuracy or reliability of data associated with particular uses of any product described herein. SCS Global Services provides independent verification of recycled content in building materials and verifies recycled content claims made by manufacturers. For more information, visit www.SCSglobalservices.com. LEED® is a registered trademark of the U.S. Green Building Council. Pub. No. 10013811-F. Printed in U.S.A. June 2020. © 2020 Owens Corning. All Rights Reserved. OWENS CORNING INSULATING SYSTEMS, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 www.owenscorning.com Design Considerations •For optimum insulation performance the building thermal barrier (insulation) should be in continual alignment with the building air barrier. In framed cavities, the product thickness should match the depth of the framing members. •Follow the local, applicable building code(s) to determine the need for and placement of a vapor retarder. •Do not install insulation on top, or within 3 inches of a recessed light fixture unless the fixture is labeled as “insulation contact” (IC) rated. •Kraft and standard foil facings will burn and cannot be left exposed. Install facings in substantial contact with the assembly finish material. Protect from open flame or other heat source. Installation See Owens Corning publication “Installation Guide for Light Density Insulation” (Pub. No. 10017858) for more information. Environmental and Sustainability Owens Corning is a worldwide leader in building material systems, insulation and composite solutions, delivering a broad range of high-quality products and services. Owens Corning is committed to driving sustainability by delivering solutions, transforming markets and enhancing lives. More information can be found at www.owenscorning.com. Certifications and Sustainable Features •Certified by SCS Global Services to contain an average of 65% with minimum 47% post-consumer and balance 18% pre-consumer recycled glass content •GREENGUARD Certified products are certified to GREENGUARD standards for low chemical emissions into indoor air during product usage. GREENGUARD validated to be Formaldehyde free. For more information, visit ul.com/gg •Environmental Product Declaration (EPD) has been certified by UL Environment Notes Fiberglass products may cause temporary skin and mucous membranes itching due to the mechanical abrasion effects of fibers, a condition which is completely reversible. Owens Corning does not recommend the use of unfaced EcoTouch® PINK® Fiberglas™ Insulation in exposed applications where it will be subject to routine human contact due to this potential temporary irritation. For additional information, refer to the Safe Use Instruction Sheet (SUIS) found in the SDS Database via http://sds.owenscorning.com. *