25 CONGRESS STREET - BUILDING JACKET .-
,.
`'�l
1
`'�
��
CITY OF SALEM Fee Paid$......5.....O 0
FIRE DEPARTMENT - FIRE PREVENTION BUREAU
" Salem, Massachusetts 01970
a
ryy�e
Date, Aug. 13, 1980
rr.0IT'
In accordance with the provisions of Chapter 148, G.I. as provided in 10A
this permit is granted to
Name Wayne Strout for Pi cker•=n� Wharf Marina
(Full name of pereon,firm or corpnm granted permit)
to remove one 1,000 gal , steel tank from present location
State clearly
purpose for and to store same aboveground for un to six months
l —
which permit _ Tank is scheduled to be used for waste oil
is granted
�1 As per Fire Prevention Regulations.
f( Restrictions: P €'
at C
(Give location by street and no., or describe in such manner- t pro d adequ a deAlih of location)
This permit will expire
2/13/81 sibal(sl official permit)
(Title)
(THIS PERMT MUST BE CONSPICUOUSLY POSTED UPON THE PREMISES.) "%
Form #90 (7/77)
r,
J
1
�t
eHY�yy�m
.'{i $. � ,
XXXXXXXXXX One Salem Green
May 10, 1977
Salem Marine Basin
P.O. Box 566
Salem, Massachusetts 01970
RE: 25 Congress Street
Gentlemen:
At the request of the Salem Fire Department this Department
inspected the premises known as Salem Marine Basin, located
at 25 Congress Street , on May 39 1977•
The inspection revealed the following violations that require
correction prior to the idduance of a Certificate of Occupancy.
1 . The windows presently installed in the block wall sepOrating
the addition from the shop -area must be removed and blocked with
two (2) hour fire rated material.
2. The garage type overhead door separating the addition from
the shop area must be replaced with a two (2) hour fire raged
door or shutter.
3. The two (2) openings at the first lending of the interior
stairway to the store area requires class "B" doors and assemblies.
4. All wood and Joists exposed in new addition will be covered
with two (2) hour fire rated materials.
5. The top of the interior stairway at the second floor level of
the new addition shall be enclosed in two (2) hour rated partitions
and ceiling. A class "B" fire rated door and assembly will be
requited.
6. Decorative glass in the dividing wall between the addition and
the store area will be replaced with two (2) hour rated material.
-2-
7. The boiler in the shop area will be enclosed with two (2)
hour partitions and ceiling. A class "B" fire rated door and
assembly will be required.
8. In addition, ag per the Ordinances of the City of Salem, a
Certificate of Inspection is required prior to occupancy. You
will find an application enclosed, please fill it out and return
it to us with a check for $25.00 made out to the City of Salem.
Very truly yours,
John B. Powers, Superintendent of Public Property,
Inspector of Buildings
JBP/mlr
itLj of
"ke a��� 3�ixt 4�zpurYsnznY "zFtza��u�rYzrg ��'
�ames �. �Rxrnnxn
May 4, 1977
Salem Marine Basin Re: 25 Congress Street
25 Congress Street
P. O— Box- 566
Salem, Mass. 01970
Sirs:
As a result of . an inspection made by this office on May 4, 1977
in connection with the requested approval for increased storage
of Class I flammables (Gasoline ) ; the following conditions were
.found at the time of inspection.
1. Inspection was conducted jointly with Ass ' t Building; Inspector
viilliam Munroe, (Wire Inspector Paul Tuttle and Fire Inspector
Raymond T. Dansreau.
2. Application for License as submitted to this office on April 28,
1977 is hereby returned unsigned, as it does not meet the require-
ments of this office, due to conditions existing at the site.
a. Failure to renew by application for a service station, under
provisions of the Salem Fire Code, as of March 1 , 1977. This
office mailed original application in February of 1977 and
a follow-up notice was mailed in March of 1977; with no response
forthcoming,
b. It has been found that a portable oxygen./acetvlene unit is
being used on the premises, without first obtaining a permit
for same. This is a violation of the Salem Fire Code.
c. Storage of Class A flammables in mercantile occupancy without
a permit and out in the open. (Acetone based cleaner)
d, Storage of Class B flammables in mercantile occupancy without
a permit. (Paints)
e. Operation of mixed occupancies without proper enclosures. ewalls ,
doors and open stairways.
f. No lock provided on the dispensing pump for gasoline.
g. Several electrical deficiencies which are to be noted in the
report from the 'Wire inspector.
h. Requesting the plumbing inspector to determine the drain
requirements for the floor drains.
Report of inspection at 23-25 Conrre:;s Stree:i;, Salem on 5/4/77
Paget
i. Fuel oil burner, shall be encloF. rj rer Section lil3. o
of the State Building, Code. A duoolicate permit for
storage of fuel oil and operation of the oil burner will
be issued upon compliance with above order:
-- j. One 10,T" ABC fire extinguisher st:a.11 be mounted on bracket
in the retail occupancies, ( eaci' shriviroom) within 10 feet
of egress door. One 10;r ABC f_.re ex onguisher shall be
mounted on bracket in. present loser level work area, within
10 feet of egress door. One 204 A-_—: fire extinguisher shall
be mounted on bracket in nee: io,ser level. workshop areas,
each exting 1,i.sher to be til. ='_."_r. l-(I fce .. of each -egress. This
will re wire U 201T A'_51" •e:: s yr
q .ingui.s:;: because of -the
concrete block, divider wall to be installed.
It--is to be noted that the correct address for this occupancy
per City of Salem Assessors records is s25 0ongress Street, Salem.
The application for increased st:orac= shall show this address.
Thirty days from the date of tills 1 t-, r, ."e- owners of the Salem
Purine Basin may resubmit the ap;oltcati.cn for increased storage
of Class A flammables , for Fire Chief' s anpl,oval. The progress
made on the violations listed by •th� vari ol_;s code officers, will
be noted and it may be possible? at that time to start the license
process for increased storage; . Ivo permit will be issued however
for the installation of a new tank until substantial compliance
with the code deficiencies has been complied with.
Enclosed for the owners are applications for operation of a service
station, use of portable welding and cutting tank operation outside
the repair areas, and an application for License increase to 5, 000
gallons total for Class A flammables (gasoline ) ; also permits for
storage of Class A and Class B flammables. for ordinary use in the
mercantile occupancy and for storage of fuel, tanks for customers.
These permits will not be issued until full compliance with the
code deficiencies are found to be corrected,
As of this date you are hereby notified that your occupancy is
operating on a temporary basis, - limited to sixty days from this
date of May 4, 1977.
These recommendations and notifications of violation of law are
made in the interest of fire prevention and to correct conditions
that are or may become dangerous as a fire hazard , may be required
for legal occupancy of the premises or are in direct violation of
law.
If at the expiration of the time allowed above „ these conditions
have not been remedied and no cause aforesaid be shown, such
furthur action will be taken as the law requires.
cc : Building Inspector Per or'er: G/
Electrical Inspector )� � �JU t
Plumbing Inspector L(/�` id J. —�'Y
file Salem Fire Dlarshal