142 CANAL STREET ASBESTOS INSPECTION REPORTLg Logo P1 Header Mark Livesey Symes Associates 50 Dodge Street Beverly, Massachusetts 01915 RE:FLI Project #:22-2576 Inspection for Asbestos Containing Materials at Dear Mr. Livesey: Inspection Summary: Asbestos Inspector:Samantha Lopez License #:AI900988 Date of Inspection: Total Materials Sampled:3 Samples Analyzed At: NIST/NVLAP Certification#:200919-0 MassDLS Lab Certification#:AA000208 FLI Environmental, Inc. performed an inspection for asbestos containing materials (ACMs) at the property located at the address noted above. This report outlines the initial visual survey, sample collection and summary of analytical results provided by FLI. Asbestos Identification Laboratory, Inc. Scope and Approach: FLI provided a state licensed and EPA AHERA accredited asbestos inspector to perform an inspection of the subject area(s). The purpose of the inspection was to identify and sample building materials suspected to contain asbestos. Suspect materials include thermal system insulation, fireproofing, soundproofing, plasters, skimcoating, spray-applied or trowel applied finishes, ceiling & floor tiles, sheet flooring, caulking, glazing, mastics, adhesives, cement board products, roofing materials and numerous other products. Materials having the same function/application, similar color, texture or other observed similar characteristics were grouped together and sampled as one homogeneous material. A minimum of 2 samples of each homogenous material were collected. December 13, 2022 December 22, 2022 142 Canal Street (Back Section at Left Rear) Salem, MA Sm Logo P2 Header 142 Canal Street (Back Section at Left Rear) Asbestos Inspection Page 2 Bulk Sampling: Asbestos Containing Materials: Non-Asbestos Containing Materials: Remarks and Limitations: 1. Bulk samples were collected in a random manner and submitted via chain of custody to the analytical laboratory. The samples were analyzed by Polarized Light Microscopy per EPA Method 600/R-93-116, July 1993. The detection limit of the EPA recommended method is one percent asbestos by weight. Materials containing greater than one percent asbestos are treated as asbestos-containing as required by the EPA. The laboratory is accredited by the National Institute of Standards and Technologies NIST/NVLAP Program and licensed by the Massachusetts Department of Labor Standards (DLS) for asbestos analysis in bulk materials. Homogeneous materials determined to be non-suspect by the inspector (if observed), include concrete floors, wood flooring/joists, concrete block, black/brown vinyl flexible duct connectors, fiberglass insulation, armaflex (neoprene) insulation, rubber, plastic, ceramic tile, glass and metal. Any homogeneous material having at least one (1) sample analytically identified as containing one percent (1%) asbestos or greater is categorized as an asbestos containing material. Any material analytically identified as containing any asbestos fibers is categorized as an asbestos containing waste material. A summary of materials identified to contain asbestos is provided in Appendix A including approximate location(s) of the material and estimated quantities. Laboratory Analytical Data Sheets for each sample analyzed are included in Appendix C. Homogeneous materials where each sample analyzed was determined not to contain asbestos are categorized as non-asbestos. A summary of non-asbestos materials is provided in Appendix B. Laboratory Analytical Data Sheets for each sample analyzed are included in Appendix C. December 22, 2022 If present, areas within walls, drywall encased columns and above ceilings were inspected where possible in accessible representative locations. However, each individual enclosed area was not inspected. Accessible areas beneath such surfaces were examined and sampled, and material quantities were estimated based on these observations. Additional suspect materials may be present beneath surfaces (multiple layers) or within chases or crawlspace areas that were unknown or unaccessible at the time of the inspection but may be discovered during demolition, renovation or maintenance activities. Any additional suspect materials not identified in this report that become exposed during building renovation, maintenance or demolition should be sampled and analyzed for asbestos content prior to disturbing. Sm Logo P3 Header 142 Canal Street (Back Section at Left Rear) Asbestos Inspection Page 3 2. 3. Should you have any questions or need additional information, please contact our office at (781) 251-0040. Thank you for the opportunity to provide you with our services and we look forward to working together in the future. None of the suspect materials sampled were determined to have asbestos fibers present when analyzed by Polarized Light Microscopy This report is not meant to be used as an asbestos abatement plan or abatement specification. Material quantities and locations are estimates and approximations and should not be used to obtain pricing from contractors. FLI recommends contracting for abatement after an abatement specification is prepared by a licensed Asbestos Project Designer. December 22, 2022 142 Canal Street (Back Section at Left Rear) Asbestos Inspection Appendix A APPENDIX A Asbestos Containing Materials Summary Table December 22, 2022 NONE OF THE MATERIALS SAMPLED WERE IDENTIFIED AS ASBESTOS CONTAINING 142 Canal Street (Back Section at Left Rear) Asbestos Inspection Appendix B Sample # ('s)Material Sample Location A Sample Location B Sample Location C 2576-01A,B White Door Exterior Caulking Left Facing Left Facing 2576-02A,B Perimeter Flashing Left Side Right Side 2576-03A,B,C Vent Flashing Roof Roof Roof APPENDIX B Suspect Materials Found Not to Contain Asbestos December 22, 2022 142 Canal Street (Back Section at Left Rear) Asbestos Inspection Appendix C December 22, 2022 APPENDIX C BULK SAMPLE LABORATORY DATA SHEETS Asbestos Identification Laboratory. 165 New Boston St., Ste 227 Woburn, MA 01801 781-932-9600 Web: www.asbestosidentificationlab.com Email: mikemanning@asbestosidentificationlab.com Batch: 89051 Dear Samantha Lopez, Thank you Samantha Lopez for your business. Michael Manning Owner/Director Asbestos Identification Laboratory has completed the analysis of the samples from your office for the above referenced project. The Analysis Method is BULK PLM ANALYSIS, EPA/600/R-93/116The information and analysis contained in this report have been generated using the EPA /600/R-93/116 Method for the Determination of Asbestos in Bulk Building Materials. Materials or products that contain more than 1% of any kind or combination of asbestos are considered an asbestos containing building material as determined by the EPA. This Polarized Light Microscope (PLM) technique may be performed either by visual estimation or point counting. Point counting provides a determination of the area percentage of asbestos in a sample. If the asbestos is estimated to be less than 10% by visual estimation of friable material, the determination may be repeated using the point counting technique. The results of the point counting supersede visual PLM results. Results in this report only relate to the items tested. This report may not be used by the customer to claim product endorsement by NVLAP or any other U.S. Government Agency. Samantha Lopez FLI Environmental 69 Bridge Street Dedham, MA 02026 Project Information 22-2576 142 Canal Street (Back Section at Left Rear) Method: BULK PLM ANALYSIS, EPA/600/R-93/116 • NVLAP Lab Code: 200919-0 • Massachusetts Certification License: AA000208 • State of Connecticut, Department of Public Health Approved Environmental Laboratory Registration Number: PH-0142 • State of Maine, Department of Environmental Protection Asbestos Analytical Laboratory License Number: LB-0078(Bulk) LA-0087(Air) • State of Rhode Island and Providence Plantations. Department of Health Certification: AAL-121 • State of Vermont, Department of Health Environmental Health License AL934461 Laboratory results represent the analysis of samples as submitted by the customer. Information regarding sample location, description, area, volume, etc., was provided by the customer. Asbestos Identification Laboratory is not responsible for sample collection activities or analytical method limitations. Unless notified in writing to return samples, Asbestos Identification Laboratory discards customer samples after 30 days. Samples containing subsamples or layers will be analyzed separately when applicable. Reports are kept at Asbestos Identification Laboratory for three years. This report shall not be reproduced, except in full, without the written consent of Asbestos Identification Laboratory. Samantha Lopez FLI Environmental 69 Bridge Street Dedham, MA 02026 Project Information 22-2576 142 Canal Street (Back Section at Left Rear) Method: BULK PLM ANALYSIS, EPA/600/R-93/116 Asbestos %Material Color Non-Asbestos %LocationFieldID LabID white Non-Fibrous 100 979546 2576 -01A Left FacingWhite Door Exterior Caulking None Detected white Non-Fibrous 100 979547 2576 -01B Left FacingWhite Door Exterior Caulking None Detected black Non-Fibrous 100 979548 2576 -02A Left SidePerimeter Flashing None Detected black Non-Fibrous 100 979549 2576 -02B Right sidePerimeter Flashing None Detected black Non-Fibrous 100 979550 2576 -03A RoofVent Flashing None Detected black Non-Fibrous 100 979551 2576 -03B RoofVent Flashing None Detected black Non-Fibrous 100 979552 2576 -03C RoofVent Flashing None Detected Sampled:Received:December 15, 2022December 13, 2022 Analyzed:December 13, 2022 Analyzed by:89051Batch: Thursday 15 December Page 2 of 2 142 Canal Street (Back Section at Left Rear) Asbestos Inspection Appendix D December 22, 2022 APPENDIX D LICENSES AND CERTIFICATIONS THE COMMONWEALTH OF MASSACHUSETTS EXECUTIVE OFFICE OF LABOR AND WORKFORCE DEVELOPMENT DEPARTMENT OF LABOR STANDARDS 19 STANIFORD STREET, BOSTON, MASSACHUSETTS 02114 ASBESTOS CONSULTING SERVICE PROVIDER LICENSE F.L.I. ENVIRONMENTAL INC 69 BRIDGE ST DEDHAM, MA 02026 LICENSE: AF000049 EXPIRES: NOVEMBER 15, 2023 IN ACCORDANCE WITH MGL CH. 149 § 6B AND 454 CMR 28.00 THIS CERTIFICATE IS ISSUED BY THE DEPARTMENT OF LABOR STANDARDS TO THE CONTRACTOR ABOVE FOR THE PURTPOSE OF ENTERING INTO OR ENGAGING IN ASBESTOS WORK. THIS LICENSE IS VALID FOR A PERIOD OF ONE (1) YEAR. ______________________________________________ MICHAEL FLANAGAN, DIRECTOR United States Department of Commerce National Institute of Standards and Technology Certificate of Accreditation to ISO/IEC 17025:2017 NVLAP LAB CODE: 200919-0 Asbestos Identification Laboratory Woburn, MA is accredited by the National Voluntary Laboratory Accreditation Program for specific services, listed on the Scope of Accreditation, for: Asbestos Fiber Analysis 2022-07-01 through 2023-06-30 Effective Dates For the National Voluntary Laboratory Accreditation Program This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2017. This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communique dated January 2009).