Loading...
PB_160 Federal Street - Approved plan set (1)CONSULTANT TITLE:CONSULTANT TITLE:CONSULTANT TITLE:MECHANICAL, PLUMBING, ELECTRICAL & FIRE PROTECTION ENGINEER:CIVIL ENGINEER:STRUCTURAL ENGINEER:PROJECT TEAM:LOCUS MAP:OWNER/DEVELOPER:ARCHITECT:PLOTTED ON:ISSUE DATE:ICON ARCHITECTURE101 Summer Street, Boston, MA 02110617.451.33332/12/2020 4:03:14 PM160 FEDERAL STREETSALEM HISTORIC SCHOOLSFEBRUARY 13, 2020NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.SITE PLAN REVIEWNORTH SHORE COMMUNITY DEVELOPMENT COALITION96 LAFAYETTE STREET, SALEM, MA 01970LIM CONSULTANTS, INC6 PLEASANT ST, MALDEN, MA 02148NITSCH ENGINEERING, INC2 CENTER PLZ #430, BOSTON, MA 02108WOZNY BARBAR & ASSOCIATES INC1076 WASHINGTON ST, HANOVER, MA 02339VHB99 HIGH ST #10, BOSTON, MA 02110IRWIN ENGINEERS INC33 W CENTRAL ST, NATICK, MA 01760XX WG6"7.0' WIDEApprox.buriedwells.DNDNDN7.0' WIDEWG544 SF1BRG05ELEV592 SF1BRG06749 SF2BRG04559 SF1BRG03462 SFSTUDIOG02440 SFSTUDIOG01167 SFLAUNDRY002A487 SFWELLNESS/ACTIVITY003UUUUUUNEW RESILIENT FLOORING AT CORRIDORSHISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN POSITION, TYP HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE. HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.PROTECT & MAINTAIN HISTORIC GLAZING SYSTEM; REMOVE RETROFIT METAL DOOR AND PROVIDE NEW RATED ENTRY DOOR & VESTIBULEMAINTAIN EXISTING CLASSROOM DEMISING WALLS WHERE POSSIBLE; HISTORIC TRIM TO BE RETAINED & RESTORED WHERE POSSIBLE.REMOVE EXISTING RETROFIT DOOR & TRANSOM ASSEMBLY; PROVIDE NEW GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP.HISTORIC TRIM [INC WAINSCOT, FLOOR BASE, SCOTIA MOULDINGS] TO BE RETAINED & RESTORED AS HIGHLIGHTED, TYPPAINT/REFINISH EXISTING PAINTED MASONRY CORRIDOR WALLSINFILL EXISTING BOILER ROOM TO MEETCORRIDOR FLOOR ELEVATIONPROTECT & MAINTAIN EXPOSED BRICK ARCH & HISTORIC MASONRY WHERE POSSIBLEEXTERIOR SUBGRADE MASONRY WALL TO RECEIVE INTERIOR WATERPROOFING ASSEMBLYHISTORIC MASONRY TO BE EXPOSED WHERE POSSIBLE, TYPEXISTING DOOR TO BE REMOVED; NEW HISTORICALLY SENSITIVE OPAQUE GLAZING SYSTEM TO INFILL EXISTING MASONRY OPENINGPROVIDE NEW METAL DOORSYSTEMA-202.3A-202.5A-2012A-2011A-202.4OPEN AREAWAY TO PROVIDE NEW WINDOW IN EXISTING HISTORIC MASONRY OPENING, WINDOW SYSTEM TO REPLICATE ORIGINAL CONFIGURATION PER DWGS, TYPBUILDINGSERVICEPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMREMOVE RETROFIT INFILL MATERIAL & PROVIDE NEWWINDOW SYSTEM TO REPLICATE ORIG. CONFIG. TYP PROVIDE OPENING FOR NEW ELEVATOR DOORCOFFEE STOP179 SFCOMMONLOUNGE001MAIL335 SFCOMMONLOUNGE002WCWASHELEV: 18.95VESTELEV: 17.72PATIOSLOPED WALK 1:20PATIOB.O. STAIR21.7ELEV: 17.61ELEV: 17.72ZERO CURBELEV: 18.95NEW COVERED ENTRYPLANTERSDNTRASHB.O. RISER ELEV: 19.8T.O. RISER/WALKWAY ELEV: 21.1EQEQEQUPDNUPDN597 SF1BR106560 SF1BR105797 SF2BR104796 SF2BR103462 SFST102457 SFST101ELEVINFILL EXISTING STAIR OPENING TO MEET CORRIDOR FLOOR ELEVATIONRETROFIT EXISTING RAMP FOR COMPLIANT ACCESSIBLE SECONDARY ENTRY FROM STREETREMOVE EXISTING RETROFIT DOOR & TRANSOM ASSEMBLY; PROVIDE NEW GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP.REMOVE EXISTING RETROFIT DOOR & TRANSOM ASSEMBLY; PROVIDE NEW GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP.HISTORIC TRIM [INC WAINSCOT, FLOOR BASE, CHALK RAILS, SCOTIA MOULDINGS] TO BE RETAINED & RESTORED AS HIGHLIGHTED, TYPHISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN POSITION, TYP HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.UUUUUU HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.INSTALL NEW RATED DOOR INEXISTING OPENING; HISTORIC CLASSROOM ENTRY DOOR TO BE RETAINED & FIXED IN OPEN POSITION; EXISTING DOOR TRIMTO BE REINSTALLED. HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.MAINTAIN EXISTING CLASSROOM DEMISINGWALLS WHERE POSSIBLE; HISTORIC TRIM TOBE RETAINED & RESTORED WHERE POSSIBLE.FEDERAL STHISTORIC TRIM [INC WAINSCOT, FLOOR BASE, SCOTIA MOULDINGS] TO BE RETAINED & RESTORED AS HIGHLIGHTED, TYPA-202.3A-202.5A-2012A-2011A-202.4NEW RESILIENT FLOORING AT CORRIDORSPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMPROTECT, MAINTAIN & RESTORE EXISTING HARDWOOD FLOORS AT CLASSROOMS WHERE POSSIBLE, TYPENLARGE EXISTING CLASSROOM OPENING FOR NEW ELEVATOR DOOR; REPLICATE TRIM AT OPENING, PTD, TYPA-6013QUIET STOP LIBRARYHISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN POSITION, TYP536 SF1BR107363 SFST108560 SF1BR109NEW ROOF OUTLINE BELOWPROPOSED TRASH CHUTE ACCESSLEGENDAREA OF FLOOR INFILLAREA OF HISTORIC TRIMAREA OF HISTORIC CHALK BOARDS & RAILSARCHITECTCONSULTANTSTAMPKEY PLANSHEET TITLEPROJECT NUMBER:DRAWN BY:CHECKED BY:2/12/2020 4:02:39 PMA-101GARDEN LEVEL andFIRST FLOOR PLAN160 FEDERAL STREETSALEM HISTORIC SCHOOLSNORTH SHORE COMMUNITY DEVELOPMENTCOALITION, INC.218010.1BDChecker4'08'16'1/8" = 1'-0"1PROPOSED GARDEN LEVEL FLOOR PLAN1/8" = 1'-0"2FIRST FLOOR PLANNORTHMARK DATE DESCRIPTION8/31/2018 MHC SUBMISSION UPDNUPDN818 SF2BR204818 SF2BR203568 SF1BR205474 SFST202463 SFST201601 SF1BR206ELEV539 SF1BR207363 SFST208563 SF1BR209A-500STA-5002BRA-5001BRINFILL EXISTING STAIR OPENING TO MEET CORRIDOR FLOOR ELEVATIONUUUUUUUUUHISTORIC TRIM [INC WAINSCOT, FLOOR BASE, CHALK RAILS, SCOTIA MOULDINGS] TO BE RETAINED & RESTORED AS HIGHLIGHTED, TYPHISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN POSITION, TYP HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE. HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.INSTALL NEW RATED DOOR INEXISTING OPENING; HISTORIC CLASSROOM ENTRY DOOR TO BE RETAINED & FIXED IN OPEN POSITION; EXISTING DOOR TRIMTO BE REINSTALLED. HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.MAINTAIN EXISTING CLASSROOM DEMISINGWALLS WHERE POSSIBLE; HISTORIC TRIM TOBE RETAINED & RESTORED WHERE POSSIBLE.HISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN POSITION, TYPHISTORIC TRIM [INC WAINSCOT, FLOOR BASE, SCOTIA MOULDINGS] TO BE RETAINED & RESTORED AS HIGHLIGHTED, TYPA-2012A-2011A-202.4NEW RESILIENT FLOORING AT CORRIDORSPROTECT & MAINTAIN HISTORIC GLAZING SYSTEM; REMOVE RETROFIT METAL DOOR AND PROVIDE NEW RATED ENTRY DOOR & VESTIBULEPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMENLARGE EXISTING CLASSROOM OPENING FOR NEW ELEVATOR DOOR; REPLICATE TRIM AT OPENING, PTD, TYPPROPOSED TRASH CHUTE ACCESS818 SF2BR304818 SF2BR303568 SF1BR305475 SFST302464 SFST301539 SF1BR307600 SF1BR306356 SFST308570 SF1BR309ELEVUPDNDNINFILL EXISTING STAIR OPENING TO MEET CORRIDOR FLOOR ELEVATIONHISTORIC TRIM [INC WAINSCOT, FLOOR BASE, CHALK RAILS, SCOTIA MOULDINGS] TO BE RETAINED & RESTORED AS HIGHLIGHTED, TYPHISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN POSITION, TYP HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE. HISTORIC DOOR TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND, TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.INSTALL NEW RATED DOOR INEXISTING OPENING; HISTORIC CLASSROOM ENTRY DOOR TO BE RETAINED & FIXED IN OPEN POSITION; EXISTING DOOR TRIMTO BE REINSTALLED; INSTALL RATED (PTD GWB) ASSEMBLY BEHIND ETR TRANSOM WINDOW HISTORIC DOOR & TRANSOM TO BE FIXED IN PLACE IN SAME LOCATION ON ONE SIDE OF DEMISING WALL W/ RATED GWB INFILL WALL BEHIND (PTD), TYP. ALL HISTORIC TRIM & HARDWARE TO BE RETAINED/REINSTALLED WHERE POSSIBLE.MAINTAIN EXISTING CLASSROOM DEMISINGWALLS WHERE POSSIBLE; HISTORIC TRIM TOBE RETAINED & RESTORED WHERE POSSIBLE.HISTORIC CLASSROOM ENTRY DOORS TO BE RETAINED & FIXED IN OPEN POSITION, TYPHISTORIC TRIM [INC WAINSCOT, FLOOR BASE, SCOTIA MOULDINGS] TO BE RETAINED & RESTORED AS HIGHLIGHTED, TYPUUUUUUUUUA-202.3A-2012A-2011A-202.4NEW RESILIENT FLOORING AT CORRIDORSPROTECT & MAINTAIN HISTORIC GLAZING SYSTEM; REMOVE RETROFIT METAL DOOR AND PROVIDE NEW RATED ENTRY DOOR & VESTIBULEPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMPROTECT & MAINTAIN EXISTING CORRIDOR DOOR & GLAZING SYSTEMENLARGE EXISTING CLASSROOM OPENING FOR NEW ELEVATOR DOOR;REPLICATE TRIM AT OPENING; PTD, TYPLOW ACCESS GATEPROPOSED TRASH CHUTE ACCESSLEGENDAREA OF FLOOR INFILLAREA OF HISTORIC TRIMAREA OF HISTORIC CHALK BOARDS & RAILSARCHITECTCONSULTANTSTAMPKEY PLANSHEET TITLEPROJECT NUMBER:DRAWN BY:CHECKED BY:2/12/2020 4:02:43 PMA-102SECOND and THIRDFLOOR PLAN160 FEDERAL STREETSALEM HISTORIC SCHOOLSNORTH SHORE COMMUNITY DEVELOPMENTCOALITION, INC.218010.1BDChecker1/8" = 1'-0"1SECOND FLOOR PLAN1/8" = 1'-0"2THIRD FLOOR PLAN4'08'16'NORTHMARK DATE DESCRIPTION DNA-202.3A-202.5A-2012A-2011A-202.4ELEVATOR OVER RUNELEVATORCONTROLROOMUNASSIGNED; NOCOMMON USEUNASSIGNED; NOCOMMON USEREMOVE EXISTING HARDWARE & PROVIDE NEWPROTECT & MAINTAIN EXISTING HISTORIC GLAZED PARTITION & DOOR ASSEMBLYA-202.3A-202.5A-2012A-2011VENT FOR ELEVATOR BELOWEXISTING SLATE ROOF TO REMAIN;REPAIR IN KINDEXISTING COPPER ROOFING & FLASHINGTO BE REFURBISHED WHERE POSSIBLE, TYPEXISTING COPPER FLASHING & GUTTERS TOBE REFURBISHED WHERE POSSIBLE, TYPREFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYPARCHITECTCONSULTANTSTAMPKEY PLANSHEET TITLEPROJECT NUMBER:DRAWN BY:CHECKED BY:2/12/2020 4:02:44 PMA-103ATTIC and ROOFPLAN160 FEDERAL STREETSALEM HISTORIC SCHOOLSNORTH SHORE COMMUNITY DEVELOPMENTCOALITION, INC.218010.1BDChecker4'08'16'1/8" = 1'-0"1UNDERSIDE OF TRUSS1/8" = 1'-0"2ROOFMARK DATE DESCRIPTION LEVEL 131' -2 51/128"LEVEL 244' -4 51/128"ROOF95' -3 51/128"THIRD FLOORPLAN57' -6 51/128"UNDERSIDE OFTRUSS73' -3 51/128"VIF15' - 9"VIF13' - 2"VIF13' - 2"REMOVE EXISTING RETROFIT DOORASSEMBLY; PROVIDE NEW GLAZED METALDOOR SYSTEM TO REPLICATE ORIGINALCONFIGURATIONS PER ORIG. DWGS, TYPREMOVE INFILL AT PREVIOUS TRANSOM OPENINGTO ACCOMODATE NEW TRANSOM WINDOW SYSTEMTO REPLICATE ORIGINAL CONFIGURATIONS, TYPREMOVE EXISTING WINDOW AND CASING TRIM,CATALOGUE & STORE ONSITE, REFINISH & REINSTALLIN LOCATION OF REMOVAL-TYP. REFERENCE SPECIFICATIONS FOR REFINISHING PROCEDURES.REMOVE INFILL AT PREVIOUS TRANSOM OPENINGTO ACCOMODATE NEW TRANSOM WINDOW SYSTEMTO REPLICATE ORIGINAL CONFIGURATIONS, TYPOPEN AREAWAYEXISTING SLATE ROOF TO BE REMAIN; REPAIR IN KINDEXISTING COPPER ROOFING, FLASHING & GUTTERSTO REMAIN; REFURBISH WHERE POSSIBLEREFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYPA-800B4A-8001SimREFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYPLEVEL 131' -2 51/128"LEVEL 244' -4 51/128"GARDEN LEVELFLOOR PLAN18' -11 51/128"THIRD FLOORPLAN57' -6 51/128"UNDERSIDE OFTRUSS73' -3 51/128"REMOVE EXISTING WINDOW AND CASING TRIM,CATALOGUE & STORE ONSITE, REFINISH & REINSTALLIN LOCATION OF REMOVAL-TYP. REFERENCE SPECIFICATIONS FOR REFINISHING PROCEDURES.REFERENCE SPECIFICATIONS FOR STONE RESTORATIONS, TYPEXISTING COPPER ROOFING, FLASHING & GUTTERS TO REMAIN, REFURBISH WHERE POSSIBLE, TYPEXISTING SLATE ROOF TO REMAIN; REPAIR IN KINDA-8001ELEVATOR VENTREFERENCE SPECIFICATIONS FOR STONE RESTORATIONS, TYPPARKING LOT17' -8 41/64"NEW COVERED ENTRY BYNDARCHITECTCONSULTANTSTAMPKEY PLANSHEET TITLEPROJECT NUMBER:DRAWN BY:CHECKED BY:2/12/2020 4:02:55 PMA-201PROPOSED BUILDINGELEVATIONS160 FEDERAL STREETSALEM HISTORIC SCHOOLSNORTH SHORE COMMUNITY DEVELOPMENTCOALITION, INC.218010.1BDChecker4'08'16'1/8" = 1'-0"2SOUTH ELEVATION -PROPOSED1/8" = 1'-0"1WEST ELEVATION - PROPOSED21MARK DATE DESCRIPTION LEVEL 131' -2 51/128"LEVEL 244' -4 51/128"GARDEN LEVELFLOOR PLAN18' -11 51/128"THIRD FLOORPLAN57' -6 51/128"UNDERSIDE OFTRUSS73' -3 51/128"REMOVE EXISTING RETROFIT DOORASSEMBLY; PROVIDE NEW GLAZED METALDOOR SYSTEM TO REPLICATE ORIGINALCONFIGURATIONS PER ORIG. DWGS, TYPREMOVE EXISTING WINDOW AND CASING TRIM,CATALOGUE & STORE ONSITE, REFINISH & REINSTALLIN LOCATION OF REMOVAL-TYP. REFERENCE SPECIFICATIONS FOR REFINISHING PROCEDURES.EXISTING SLATE ROOF TO BE REMAIN; REPAIR IN KINDEXISTING COPPER ROOFING, FLASHING & GUTTERSTO REMAIN; REFURBISH WHERE POSSIBLEPROVIDE NEW METAL DOOR SYSTEMREMOVE EXISTING RETROFIT INFILL MATERIAL. REMOVE EXISTING WINDOW & CASING TRIM, CATALOGUE & STORE ONSITE, REFINISH & REINSTALL IN LOCATION OF REMOVAL WHERE POSSIBLE, TYP. REFERENCE SPECIFICATIONS FOR REFINISHING PROCEDURES.A-800B3REMOVE EXISTING INFILL MATERIAL; PROVIDE NEW WINDOW SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYPPARKING LOT17' -8 41/64"NEW COVERED ENTRY CANOPYLEVEL 131' -2 51/128"LEVEL 244' -4 51/128"GARDEN LEVELFLOOR PLAN18' -11 51/128"THIRD FLOORPLAN57' -6 51/128"UNDERSIDE OFTRUSS73' -3 51/128"BOILER ROOM16' -8 51/128"REMOVE EXISTING WINDOW AND CASING TRIM,CATALOGUE & STORE ONSITE, REFINISH & REINSTALLIN LOCATION OF REMOVAL-TYP. REFERENCE SPECIFICATIONS FOR REFINISHING PROCEDURES.EXISTING SLATE ROOF TO BE REMAIN; REPAIR IN KINDEXISTING COPPER ROOFING, FLASHING & GUTTERSTO REMAIN; REFURBISH WHERE POSSIBLEREMOVE EXISTING RETROFIT DOOR & TRANSOM ASSEMBLY; PROVIDE NEW GLAZED METAL DOOR & TRANSOM SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP.PARKING LOT17' -8 41/64"NEW COVERED ENTRY BYNDEXISTING DOOR TO BE REMOVED;NEW HISTORICALLY SENSITIVE DOOR ORGLAZING SYSTEM TO INFILL EXISTING MASONRY OPENINGREMOVE EXISTING WINDOW AND CASING TRIM,CATALOGUE & STORE ONSITE, REFINISH & REINSTALLIN LOCATION OF REMOVAL-TYP. REFERENCE SPECIFICATIONS FOR REFINISHING PROCEDURES.ARCHITECTCONSULTANTSTAMPKEY PLANSHEET TITLEPROJECT NUMBER:DRAWN BY:CHECKED BY:2/12/2020 4:03:07 PMA-202.PROPOSED BUILDINGELEVATIONS160 FEDERAL STREETSALEM HISTORIC SCHOOLSNORTH SHORE COMMUNITY DEVELOPMENTCOALITION, INC.218010.1BDChecker1/8" = 1'-0"5NORTH ELEVATION1/8" = 1'-0"3EAST ELEVATION1/8" = 1'-0"4PARTIAL NORTH ELEVATION4'08'16'435MARK DATE DESCRIPTION EXISTING WOOD WINDOW RESTORATION SCOPE:• REMOVE EXISTING WINDOW & CASING TRIM; CATALOGUE & STORE ONSITE DURING DEMOLITION• REMOVE EXISTING PAINT; COORDINATE ALL PROCEDURES PER ENVIRONMENTAL CONSULTANT• REGLAZE• PROVIDE NEW HARDWARE INCLUDING POWER ASSIST• PAINT AND REFINISH PER SPECIFICATIONS• REINSTALL IN LOCATION OF REMOVAL• PROVIDE NEW INTERIOR ENERGY STORMSETR STONE SILL; REFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYP.3' - 8" MO, VIF8' - 1 3/8" MO, VIF4"1 1/4"5"13/16"2"4"ARCHITECTCONSULTANTSTAMPKEY PLANSHEET TITLEPROJECT NUMBER:DRAWN BY:CHECKED BY:2/12/2020 4:03:09 PMA-800WINDOW DETAILSRESTORATION -HISTORIC APPROACH160 FEDERAL STREETSALEM HISTORIC SCHOOLSNORTH SHORE COMMUNITY DEVELOPMENTCOALITION, INC.218010.1BDChecker1 1/2" = 1'-0"1WINDOW ELEVATION, TYPEXISTING WOOD CLASSROOM WINDOW TO BE RESTORED, TYPMARK DATE DESCRIPTION ETR STONE SILL; REFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYP.REMOVE EXISTING INFILL MATERIAL; PROVIDE NEW WINDOW SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP4 1/2"1 1/2"4"4' - 8 23/256"1 1/4"3' - 8"CDAETR EXTERIOR WALLREUSE EXISTING WINDOWCASING OR MATCH EXISTING, TYPPT WD BLOCKING AS REQ'DETR STONE SILL, TYP; REF SPECS FOR STONE RESTORATIONETR EXTERIOR WALLNEW JAMB FLASHING BYNDNEW ALUM WINDOW SYSTEM, TYPMEETING RAILBRICK BEYONDAPPLIED VERT MUNTIN BYNDFILL VOIDS WITH LOWEXPANDING FOAM INSUL (NEW)NEW JAMB FLASHING BYNDNEW SELF ADHEREDMEMBRANE FLASHINGNEW MTL SILL PAN FLASHINGW/ UPTURNED LEGNEW ALUM PANNING1 1/2"REVEAL WINDOW UNIT VARIES, VIFINTERIOREXTERIORINTERIOR WINDOW SCREENINTERIOR WINDOW SCREENNEW PT WD BLOCKING, TYPFINISH/SEAL & PAINT ETRMASONRY RETURNBRICK BEYONDFINISH/SEAL & PAINT ETRMASONRY RETURNFINISH/SEAL & PAINT ETRMASONRY RETURNFILL VOIDS W/ LOW EXPANSION FOAM INSULEXISTING STEEL LINTEL TO BE PRIMED/PAINTED, AS REQ'D4"5"FINISH/SEAL & PAINT ETR MASONRY WALLAPPLIED VERT MUNTIN BYNDNEW WD STOOL TO MATCHEXISTING, TYPSPACER BAR AT APPLIED MUNTINAPPLIED MUNTINSPACER BAR AT APPLIED MUNTINAPPLIED MUNTIN13/16"13/16"ABCBD• REMOVE EXISTING INFILL MATERIAL AT HISTORIC TRANSOM OPENING• COORDINATE ALL PROCEDURES PER ENVIRONMENTAL CONSULTANT• PROVIDE NEW WINDOW SYSTEM TO REPLICATE ORIGINAL CONFIGURATIONS PER ORIG. DWGS, TYP• PROVIDE NEW INTERIOR ENERGY STORMSRE-OPEN EXISTING AREAWAY8"4' - 10"5' - 0"4"13/16"1 3/4"4"13/16"1 3/4"4"REFERENCE SPECIFICATIONS FOR MASONRY RESTORATION, TYPETR STONE BANDING; REFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYPDBCBAINTERIOREXTERIOR4"1 1/2"4 1/2"13/16"13/16"ARCHITECTCONSULTANTSTAMPKEY PLANSHEET TITLEPROJECT NUMBER:DRAWN BY:CHECKED BY:2/12/2020 4:03:14 PMA-800BWINDOW DETAILSREPLACEMENT -HISTORIC APPROACH160 FEDERAL STREETSALEM HISTORIC SCHOOLSNORTH SHORE COMMUNITY DEVELOPMENTCOALITION, INC.218010.1BDChecker3/4" = 1'-0"3REPLICATED WINDOW ELEVATION3" = 1'-0"1PROPOSED WINDOW SECTIONEXISTING WOOD WINDOW RESTORATION SCOPE:• REMOVE EXISTING INFILL MATERIALS & EXISTING METAL SCREENS• REMOVE EXISTING WINDOW & CASING TRIM; CATALOGUE & STORE ONSITE DURING DEMOLITION• REMOVE EXISTING PAINT; COORDINATE ALL PROCEDURES PER ENVIRONMENTAL CONSULTANT• REGLAZE• PROVIDE NEW HARDWARE INCLUDING POWER ASSIST• PAINT AND REFINISH PER SPECIFICATIONS• REINSTALL IN LOCATION OF REMOVAL• PROVIDE NEW INTERIOR ENERGY STORMSETR STONE SILL; REFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYP.3/4" = 1'-0"4REPLICATED WINDOW ELEVATION3" = 1'-0"2EXISTING WINDOW SECTIONREMOVE EXISTING RETROFIT INFILL MATERIAL;REPLACE W/ NEW WINDOW SYSTEM TO MATCHORIGINAL CONFIGURATIONS; COORDINATE ALL PROCEDURES PER ENVIRONMENTAL CONSULTANTETR STONE SILL; REFERENCE SPECIFICATIONS FOR STONE RESTORATION, TYP.ORIGINAL CONFIGURATIONOF INFILLED WINDOW TO BE REPLICATED[AT INFILLED AREAWAY]MARK DATE DESCRIPTION GENERAL NOTES:DEMOLITION NOTES:EROSION AND SEDIMENT CONTROL NOTES: UTILITY NOTES: EARTH MOVING AND GRADING NOTES: ABBREVIATIONSPROPOSED LEGEND ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-100 NOTES, LEGEND, AND ABBREVIATIONS ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-200 DEMOLITION PLAN ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-200 SITE PLAN DN DN DN ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION 12/30/2019 1:23:51 PMC-400 GRADING PLAN ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION 12/30/2019 1:23:51 PMC-500 UTILITY PLAN DN DN DN HC 6 CA 31 AR 1 PK 1 RG 3 MC 21 RG 4 JS 11 JS 13RB 13 VM 50 JS 7 IG 2 BG 4 JS 13 CA 4 IG 2 AG 1 RG 5 RH 6 VM 2 M&P EX. TREES & SHRUBS. REMOVE GROUNDCOVER. PLANT WITH 100 LIRIOPE PLUGS @ 8" O.C. RG 3 VM 3 AG 2 BG 4 CA 3 RG 5 CF 1 JS 3 JS 2 CA 3 RB 6 IG 1 JS 4 TO 1 CA 3 HC 1 HC 1 IG 1 JS 6 JS 6 VM 714 VM 135 VM 58 VM 1051' DEEP - 180 SF NATIVE DETENTION AREA SEED MIX (ERNST CONSERVATION SEEDS OR EQUIVALENT) 1,500 SF LOW GROWING WILDFLOWER & GRASS SEED MIX (ERNST CONSERVATION SEEDS OR EQUIVALENT) RG 2 RH 9 ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION PLANTING AND MATERIALS PLAN PLANT SCHEDULE KEY COMMON NAME LATIN NAME QUANTITY SIZE SPACING TREES AND SHRUBS AR RED MAPLE 'OCTOBER GLORY'ACER RUBRUM 1 3-3.5" CAL. B&B AS SHOWN AG AUTUMN BRILLIANCE SERVICEBERRY AMELANCHIER GRANDIFOLIA 'AUTUMN BRILLIANCE'3 2.5" - 3" CAL B&B MULTI-STEM AS SHOWN HC CAROLINA SILVERBELL HALESIA CAROLINA 8 2.5-3" CAL. B&B AS SHOWN TO AMERICAN ARBORVITAE THUJA OCCIDENTALIS 1 2.5-3" CAL. B&B AS SHOWN CF FLOWERING DOGWOOD CORNUS FLORIDA 1 2.5-3" CAL. B&B AS SHOWN IG INKBERRY HOLLY ILEX GLABRA 7 4-5' B&B AS SHOWN BG BOXWOOD BUXUS 'GREEN MOUND'8 4-5' B&B AS SHOWN PERENNIALS AND GROUNDCOVERS CA SWEET PEPPERBUSH CLETHRA ALNIFOLIA 55 2 GAL.AS SHOWN MC MUHLENBERGIA CAPILLARIS HAIRAWN MUHLY GRASS 21 2 GAL.AS SHOWN RB RHODODENDRON 'BLUE TIT'RHODODENDRON 'BLUE TIT'19 2 GAL.AS SHOWN RG RHODODENDRON 'GOLDEN LIGHTS'RHODODENDRON 'GOLDEN LIGHTS'22 2 GAL.AS SHOWN RH FRAGRANT LOW GRO SUMAC RHUS AROMATICA 'LOW-GRO'15 1 GAL AS SHOWN VD ARROWWOOD VIBURNUM DENTATUM 5 5 GAL.AS SHOWN LIRIOPE MUSCARI LILY TURF 100 6" PLUGS 8" O.C. JS BLUE STAR JUNIPER JUNIPERUS SQUAMATA 'BLUE STAR'65 2 GAL.AS SHOWN VM LESSER PERIWINKLE VINCA MINOR 750 6" PLUGS 1PSF C-600 PES/BC/AG C-700 SOIL EROSION AND SEDIMENTATION CONTROL PLAN ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION TYPICAL PAVEMENT AND HOT MIX ASPHALT BERM SECTION DETAIL FLUSH GRANITE CURB SETTING DETAIL VERTICAL GRANITE CURB SETTING DETAIL ACCESSIBLE PARKING DETAIL ACCESSIBLE PARKING STENCIL DETAIL TYPICAL PARKING STRIPING DETAIL SECTION A-A SPEED TABLE DETAIL PLAN SPEED TABLE SPEED TABLE TRAFFIC SIGN PLAN TYPICAL DRIVEWAY WITH 3' CURB RETURN DETAIL SECTION A-A CONCRETE DRIVEWAY ACCESSIBLE PARKING SIGN POST SETTING DETAIL TIMBER GUARD RAIL W/ STEEL POST DETAIL PLANSECTION · · · RETAINING WALL AND GUARDRAIL DETAIL ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-800 SITE DETAILS HOT MIX ASPHALT PAVING (TWO COURSES) DETAIL CONCRETE SIDEWALK DETAIL CONTROL JOINT DETAIL EXPANSION JOINT DETAIL TYPICAL BRICK WALK DETAIL TYPICAL CONCRETE UNIT PAVER DETAIL FLUSH CONCRETE STONE LEVEL SPREADER DETAIL SECTION A-A SECTION VIEW 12" AREA DRAIN DETAIL DOMED GRATE ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-801 SITE, MATERIAL, AND UTILITY DETAILS TYPICAL CATCH BASIN DETAIL TYPICAL DRAIN MANHOLE DETAIL STANDARD TRENCH DETAIL FOR UTILITY PIPE CATCH BASIN INSERT STORMWATER BUFFER ZONE PLAN VIEW WATER QUALITY INLET PLAN SECTION TAPPING SLEEVE, VALVE & BOX DETAIL WATER TRENCH DETAIL SECTION A-A OUTLET CONTROL STRUCTURE PLAN 8 FOOT DIAMETER DRY WELL DETAIL ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-802 UTILITY AND STORMWATER DETAILS SIDE VIEWSECTION A-A A A NOTE: PART NUMBERS WILL VARY BASED ON INLET PIPE MATERIALS. CONTACT STORMTECH FOR MORE INFORMATION. CHAMBER MAX DIAMETER OF INSERTA TEE HEIGHT FROM BASE OF CHAMBER (X) SC-310 6" (150 mm)4" (100 mm) SC-740 10" (250 mm)4" (100 mm) DC-780 10" (250 mm)4" (100 mm) MC-3500 12" (300 mm)6" (150 mm) MC-4500 12" (300 mm)8" (200 mm) INSERTA TEE FITTINGS AVAILABLE FOR SDR 26, SDR 35, SCH 40 IPS GASKETED & SOLVENT WELD, N-12, HP STORM, C-900 OR DUCTILE IRON (X) INSERTA-TEE SIDE INLET DETAIL CONVEYANCE PIPE MATERIAL MAY VARY (PVC, HDPE, ETC.) INSERTA TEE CONNECTION PLACE ADS GEOSYNTHETICS 315 WOVEN GEOTEXTILE (CENTERED ON INSERTA-TEE INLET) OVER BEDDING STONE FOR SCOUR PROTECTION AT SIDE INLET CONNECTIONS. GEOTEXTILE MUST EXTEND 6" (150 mm) PAST CHAMBER FOOT INSERTA TEE TO BE INSTALLED, CENTERED OVER CORRUGATION DO NOT INSTALL INSERTA-TEE AT CHAMBER JOINTS 6 A A B B SECTION A-A SECTION B-B FOUNDATION STONE BENEATH CHAMBERS FOUNDATION STONE BENEATH CHAMBERS UNDERDRAIN DETAIL STORMTECH CHAMBER STORMTECH END CAP OUTLET MANIFOLD ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE STORMTECH END CAP ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE STORMTECH CHAMBER DUAL WALL PERFORATED HDPE UNDERDRAIN NUMBER AND SIZE OF UNDERDRAINS PER SITE DESIGN ENGINEER 4" (100 mm) TYP FOR SC-310 & SC-160LP SYSTEMS 6" (150 mm) TYP FOR SC-740, DC-780, MC-3500 & MC-4500 SYSTEMS 5 SC-740 TECHNICAL SPECIFICATIONS PART #STUB A B C SC740EPE06T / SC740EPE06TPC 6" (150 mm)10.9" (277 mm)18.5" (470 mm)--- SC740EPE06B / SC740EPE06BPC ---0.5" (13 mm) SC740EPE08T /SC740EPE08TPC 8" (200 mm)12.2" (310 mm)16.5" (419 mm)--- SC740EPE08B / SC740EPE08BPC ---0.6" (15 mm) SC740EPE10T / SC740EPE10TPC 10" (250 mm)13.4" (340 mm)14.5" (368 mm)--- SC740EPE10B / SC740EPE10BPC ---0.7" (18 mm) SC740EPE12T / SC740EPE12TPC 12" (300 mm)14.7" (373 mm)12.5" (318 mm)--- SC740EPE12B / SC740EPE12BPC ---1.2" (30 mm) SC740EPE15T / SC740EPE15TPC 15" (375 mm)18.4" (467 mm)9.0" (229 mm)--- SC740EPE15B / SC740EPE15BPC ---1.3" (33 mm) SC740EPE18T / SC740EPE18TPC 18" (450 mm)19.7" (500 mm)5.0" (127 mm)--- SC740EPE18B / SC740EPE18BPC ---1.6" (41 mm) SC740EPE24B*24" (600 mm)18.5" (470 mm)---0.1" (3 mm) ALL STUBS, EXCEPT FOR THE SC740EPE24B ARE PLACED AT BOTTOM OF END CAP SUCH THAT THE OUTSIDE DIAMETER OF THE STUB IS FLUSH WITH THE BOTTOM OF THE END CAP. FOR ADDITIONAL INFORMATION CONTACT STORMTECH AT 1-888-892-2694. * FOR THE SC740EPE24B THE 24" (600 mm) STUB LIES BELOW THE BOTTOM OF THE END CAP APPROXIMATELY 1.75" (44 mm). BACKFILL MATERIAL SHOULD BE REMOVED FROM BELOW THE N-12 STUB SO THAT THE FITTING SITS LEVEL. NOTE: ALL DIMENSIONS ARE NOMINAL NOMINAL CHAMBER SPECIFICATIONS SIZE (W X H X INSTALLED LENGTH)51.0" X 30.0" X 85.4" (1295 mm X 762 mm X 2169 mm) CHAMBER STORAGE 45.9 CUBIC FEET (1.30 m³) MINIMUM INSTALLED STORAGE*74.9 CUBIC FEET (2.12 m³) WEIGHT 75.0 lbs.(33.6 kg) *ASSUMES 6" (152 mm) STONE ABOVE, BELOW, AND BETWEEN CHAMBERS PRE-FAB STUBS AT BOTTOM OF END CAP FOR PART NUMBERS ENDING WITH "B" PRE-FAB STUBS AT TOP OF END CAP FOR PART NUMBERS ENDING WITH "T" PRE-CORED END CAPS END WITH "PC" 90.7" (2304 mm) ACTUAL LENGTH 85.4" (2169 mm) INSTALLED LENGTH BUILD ROW IN THIS DIRECTION A A C B 51.0" (1295 mm) 30.0" (762 mm) 45.9" (1166 mm)12.2" (310 mm) 29.3" (744 mm) OVERLAP NEXT CHAMBER HERE (OVER SMALL CORRUGATION) START END 2 SC-740 CROSS SECTION DETAIL ACCEPTABLE FILL MATERIALS: STORMTECH SC-740 CHAMBER SYSTEMS PLEASE NOTE: 1.THE LISTED AASHTO DESIGNATIONS ARE FOR GRADATIONS ONLY. THE STONE MUST ALSO BE CLEAN, CRUSHED, ANGULAR. FOR EXAMPLE, A SPECIFICATION FOR #4 STONE WOULD STATE: "CLEAN, CRUSHED, ANGULAR NO. 4 (AASHTO M43) STONE". 2.STORMTECH COMPACTION REQUIREMENTS ARE MET FOR 'A' LOCATION MATERIALS WHEN PLACED AND COMPACTED IN 6" (150 mm) (MAX) LIFTS USING TWO FULL COVERAGES WITH A VIBRATORY COMPACTOR. 3.WHERE INFILTRATION SURFACES MAY BE COMPROMISED BY COMPACTION, FOR STANDARD DESIGN LOAD CONDITIONS, A FLAT SURFACE MAY BE ACHIEVED BY RAKING OR DRAGGING WITHOUT COMPACTION EQUIPMENT. FOR SPECIAL LOAD DESIGNS, CONTACT STORMTECH FOR COMPACTION REQUIREMENTS. NOTES: 1.SC-740 CHAMBERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM F2418 "STANDARD SPECIFICATION FOR POLYPROPYLENE (PP) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS", OR ASTM F2922 "STANDARD SPECIFICATION FOR POLYETHYLENE (PE) CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 2.SC-740 CHAMBERS SHALL BE DESIGNED IN ACCORDANCE WITH ASTM F2787 "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 3."ACCEPTABLE FILL MATERIALS" TABLE ABOVE PROVIDES MATERIAL LOCATIONS, DESCRIPTIONS, GRADATIONS, AND COMPACTION REQUIREMENTS FOR FOUNDATION, EMBEDMENT, AND FILL MATERIALS. 4.THE SITE DESIGN ENGINEER IS RESPONSIBLE FOR ASSESSING THE BEARING RESISTANCE (ALLOWABLE BEARING CAPACITY) OF THE SUBGRADE SOILS AND THE DEPTH OF FOUNDATION STONE WITH CONSIDERATION FOR THE RANGE OF EXPECTED SOIL MOISTURE CONDITIONS. 5.PERIMETER STONE MUST BE EXTENDED HORIZONTALLY TO THE EXCAVATION WALL FOR BOTH VERTICAL AND SLOPED EXCAVATION WALLS. 6.ONCE LAYER 'C' IS PLACED, ANY SOIL/MATERIAL CAN BE PLACED IN LAYER 'D' UP TO THE FINISHED GRADE. MOST PAVEMENT SUBBASE SOILS CAN BE USED TO REPLACE THE MATERIAL REQUIREMENTS OF LAYER 'C' OR 'D' AT THE SITE DESIGN ENGINEER'S DISCRETION. MATERIAL LOCATION DESCRIPTION AASHTO MATERIAL CLASSIFICATIONS COMPACTION / DENSITY REQUIREMENT D FINAL FILL: FILL MATERIAL FOR LAYER 'D' STARTS FROM THE TOP OF THE 'C' LAYER TO THE BOTTOM OF FLEXIBLE PAVEMENT OR UNPAVED FINISHED GRADE ABOVE. NOTE THAT PAVEMENT SUBBASE MAY BE PART OF THE 'D' LAYER ANY SOIL/ROCK MATERIALS, NATIVE SOILS, OR PER ENGINEER'S PLANS. CHECK PLANS FOR PAVEMENT SUBGRADE REQUIREMENTS. N/A PREPARE PER SITE DESIGN ENGINEER'S PLANS. PAVED INSTALLATIONS MAY HAVE STRINGENT MATERIAL AND PREPARATION REQUIREMENTS. C INITIAL FILL: FILL MATERIAL FOR LAYER 'C' STARTS FROM THE TOP OF THE EMBEDMENT STONE ('B' LAYER) TO 18" (450 mm) ABOVE THE TOP OF THE CHAMBER. NOTE THAT PAVEMENT SUBBASE MAY BE A PART OF THE 'C' LAYER. GRANULAR WELL-GRADED SOIL/AGGREGATE MIXTURES, <35% FINES OR PROCESSED AGGREGATE. MOST PAVEMENT SUBBASE MATERIALS CAN BE USED IN LIEU OF THIS LAYER. AASHTO M145¹ A-1, A-2-4, A-3 OR AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57, 6, 67, 68, 7, 78, 8, 89, 9, 10 BEGIN COMPACTIONS AFTER 12" (300 mm) OF MATERIAL OVER THE CHAMBERS IS REACHED. COMPACT ADDITIONAL LAYERS IN 6" (150 mm) MAX LIFTS TO A MIN. 95% PROCTOR DENSITY FOR WELL GRADED MATERIAL AND 95% RELATIVE DENSITY FOR PROCESSED AGGREGATE MATERIALS. ROLLER GROSS VEHICLE WEIGHT NOT TO EXCEED 12,000 lbs (53 kN). DYNAMIC FORCE NOT TO EXCEED 20,000 lbs (89 kN). B EMBEDMENT STONE: FILL SURROUNDING THE CHAMBERS FROM THE FOUNDATION STONE ('A' LAYER) TO THE 'C' LAYER ABOVE. CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57 NO COMPACTION REQUIRED. A FOUNDATION STONE: FILL BELOW CHAMBERS FROM THE SUBGRADE UP TO THE FOOT (BOTTOM) OF THE CHAMBER. CLEAN, CRUSHED, ANGULAR STONE AASHTO M43¹ 3, 357, 4, 467, 5, 56, 57 PLATE COMPACT OR ROLL TO ACHIEVE A FLAT SURFACE.2,3 18" (450 mm) MIN* 8' (2.4 m) MAX 6" (150 mm) MIN D C B A 12" (300 mm) MIN ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE ALL AROUND CLEAN, CRUSHED, ANGULAR STONE IN A & B LAYERS 12" (300 mm) MIN51" (1295 mm)6" (150 mm) MIN *TO BOTTOM OF FLEXIBLE PAVEMENT. FOR UNPAVED INSTALLATIONS WHERE RUTTING FROM VEHICLES MAY OCCUR, INCREASE COVER TO 24" (600 mm). EXCAVATION WALL (CAN BE SLOPED OR VERTICAL) PERIMETER STONE (SEE NOTE 5) SC-740 END CAP SUBGRADE SOILS (SEE NOTE 4) PAVEMENT LAYER (DESIGNED BY SITE DESIGN ENGINEER) 30" (762 mm) DEPTH OF STONE TO BE DETERMINED BY SITE DESIGN ENGINEER 6" (150 mm) MIN 1 INSPECTION & MAINTENANCE STEP 1)INSPECT ISOLATOR ROW FOR SEDIMENT A.INSPECTION PORTS (IF PRESENT) A.1.REMOVE/OPEN LID ON NYLOPLAST INLINE DRAIN A.2.REMOVE AND CLEAN FLEXSTORM FILTER IF INSTALLED A.3.USING A FLASHLIGHT AND STADIA ROD, MEASURE DEPTH OF SEDIMENT AND RECORD ON MAINTENANCE LOG A.4.LOWER A CAMERA INTO ISOLATOR ROW FOR VISUAL INSPECTION OF SEDIMENT LEVELS (OPTIONAL) A.5.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. B.ALL ISOLATOR ROWS B.1.REMOVE COVER FROM STRUCTURE AT UPSTREAM END OF ISOLATOR ROW B.2.USING A FLASHLIGHT, INSPECT DOWN THE ISOLATOR ROW THROUGH OUTLET PIPE i)MIRRORS ON POLES OR CAMERAS MAY BE USED TO AVOID A CONFINED SPACE ENTRY ii)FOLLOW OSHA REGULATIONS FOR CONFINED SPACE ENTRY IF ENTERING MANHOLE B.3.IF SEDIMENT IS AT, OR ABOVE, 3" (80 mm) PROCEED TO STEP 2. IF NOT, PROCEED TO STEP 3. STEP 2)CLEAN OUT ISOLATOR ROW USING THE JETVAC PROCESS A.A FIXED CULVERT CLEANING NOZZLE WITH REAR FACING SPREAD OF 45" (1.1 m) OR MORE IS PREFERRED B.APPLY MULTIPLE PASSES OF JETVAC UNTIL BACKFLUSH WATER IS CLEAN C.VACUUM STRUCTURE SUMP AS REQUIRED STEP 3)REPLACE ALL COVERS, GRATES, FILTERS, AND LIDS; RECORD OBSERVATIONS AND ACTIONS. STEP 4)INSPECT AND CLEAN BASINS AND MANHOLES UPSTREAM OF THE STORMTECH SYSTEM. NOTES 1.INSPECT EVERY 6 MONTHS DURING THE FIRST YEAR OF OPERATION. ADJUST THE INSPECTION INTERVAL BASED ON PREVIOUS OBSERVATIONS OF SEDIMENT ACCUMULATION AND HIGH WATER ELEVATIONS. 2.CONDUCT JETTING AND VACTORING ANNUALLY OR WHEN INSPECTION SHOWS THAT MAINTENANCE IS NECESSARY. SUMP DEPTH TBD BY SITE DESIGN ENGINEER (24" [600 mm] MIN RECOMMENDED) CATCH BASIN OR MANHOLE SC-740 END CAP OPTIONAL INSPECTION PORT SC-740 CHAMBER COVER ENTIRE ISOLATOR ROW WITH ADS GEOSYNTHETICS 601T NON-WOVEN GEOTEXTILE 8' (2.4 m) MIN WIDE STORMTECH HIGHLY RECOMMENDS FLEXSTORM PURE INSERTS IN ANY UPSTREAM STRUCTURES WITH OPEN GRATES 24" (600 mm) HDPE ACCESS PIPE REQUIRED USE FACTORY PRE-FABRICATED END CAP PART #: SC740EPE24B TWO LAYERS OF ADS GEOSYNTHETICS 315WTK WOVEN GEOTEXTILE BETWEEN FOUNDATION STONE AND CHAMBERS 5' (1.5 m) MIN WIDE CONTINUOUS FABRIC WITHOUT SEAMS ELEVATED BYPASS MANIFOLD SC-740 ISOLATOR ROW DETAIL3 STORMTECH CHAMBER SPECIFICATIONS 1.CHAMBERS SHALL BE STORMTECH SC-740 OR SC-310. 2.CHAMBERS SHALL BE MANUFACTURED FROM VIRGIN POLYPROPYLENE OR POLYETHYLENE RESINS. 3.CHAMBER ROWS SHALL PROVIDE CONTINUOUS, UNOBSTRUCTED INTERNAL SPACE WITH NO INTERNAL SUPPORT PANELS THAT WOULD IMPEDE FLOW OR LIMIT ACCESS FOR INSPECTION. 4.THE STRUCTURAL DESIGN OF THE CHAMBERS, THE STRUCTURAL BACKFILL, AND THE INSTALLATION REQUIREMENTS SHALL ENSURE THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET FOR: 1) LONG-DURATION DEAD LOADS AND 2) SHORT-DURATION LIVE LOADS, BASED ON THE AASHTO DESIGN TRUCK WITH CONSIDERATION FOR IMPACT AND MULTIPLE VEHICLE PRESENCES. 5.CHAMBERS SHALL MEET ASTM F2922 (POLYETHYLENE) OR ASTM F2418-16 (POLYPROPYLENE), "STANDARD SPECIFICATION FOR THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 6.CHAMBERS SHALL BE DESIGNED AND ALLOWABLE LOADS DETERMINED IN ACCORDANCE WITH ASTM F2787, "STANDARD PRACTICE FOR STRUCTURAL DESIGN OF THERMOPLASTIC CORRUGATED WALL STORMWATER COLLECTION CHAMBERS". 7.ONLY CHAMBERS THAT ARE APPROVED BY THE SITE DESIGN ENGINEER WILL BE ALLOWED. THE CHAMBER MANUFACTURER SHALL SUBMIT THE FOLLOWING UPON REQUEST TO THE SITE DESIGN ENGINEER FOR APPROVAL BEFORE DELIVERING CHAMBERS TO THE PROJECT SITE: a.A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE SAFETY FACTORS ARE GREATER THAN OR EQUAL TO 1.95 FOR DEAD LOAD AND 1.75 FOR LIVE LOAD, THE MINIMUM REQUIRED BY ASTM F2787 AND BY AASHTO FOR THERMOPLASTIC PIPE. b.A STRUCTURAL EVALUATION SEALED BY A REGISTERED PROFESSIONAL ENGINEER THAT DEMONSTRATES THAT THE LOAD FACTORS SPECIFIED IN THE AASHTO LRFD BRIDGE DESIGN SPECIFICATIONS, SECTION 12.12, ARE MET. THE 50 YEAR CREEP MODULUS DATA SPECIFIED IN ASTM F2418 OR ASTM F2922 MUST BE USED AS PART OF THE AASHTO STRUCTURAL EVALUATION TO VERIFY LONG-TERM PERFORMANCE. c.STRUCTURAL CROSS SECTION DETAIL ON WHICH THE STRUCTURAL EVALUATION IS BASED. 8.CHAMBERS AND END CAPS SHALL BE PRODUCED AT AN ISO 9001 CERTIFIED MANUFACTURING FACILITY. IMPORTANT - NOTES FOR THE BIDDING AND INSTALLATION OF THE SC-310/SC-740 SYSTEM 1.STORMTECH SC-310 & SC-740 CHAMBERS SHALL NOT BE INSTALLED UNTIL THE MANUFACTURER'S REPRESENTATIVE HAS COMPLETED A PRE-CONSTRUCTION MEETING WITH THE INSTALLERS. 2.STORMTECH SC-310 & SC-740 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH SC-310/SC-740/DC-780 CONSTRUCTION GUIDE". 3.CHAMBERS ARE NOT TO BE BACKFILLED WITH A DOZER OR AN EXCAVATOR SITUATED OVER THE CHAMBERS. STORMTECH RECOMMENDS 3 BACKFILL METHODS: ·STONESHOOTER LOCATED OFF THE CHAMBER BED. ·BACKFILL AS ROWS ARE BUILT USING AN EXCAVATOR ON THE FOUNDATION STONE OR SUBGRADE. ·BACKFILL FROM OUTSIDE THE EXCAVATION USING A LONG BOOM HOE OR EXCAVATOR. 4.THE FOUNDATION STONE SHALL BE LEVELED AND COMPACTED PRIOR TO PLACING CHAMBERS. 5.JOINTS BETWEEN CHAMBERS SHALL BE PROPERLY SEATED PRIOR TO PLACING STONE. 6.MAINTAIN MINIMUM - 6" (150 mm) SPACING BETWEEN THE CHAMBER ROWS. 7.EMBEDMENT STONE SURROUNDING CHAMBERS MUST BE A CLEAN, CRUSHED, ANGULAR STONE 3/4-2" (20-50 mm). 8.THE CONTRACTOR MUST REPORT ANY DISCREPANCIES WITH CHAMBER FOUNDATION MATERIALS BEARING CAPACITIES TO THE SITE DESIGN ENGINEER. 9.ADS RECOMMENDS THE USE OF "FLEXSTORM CATCH IT" INSERTS DURING CONSTRUCTION FOR ALL INLETS TO PROTECT THE SUBSURFACE STORMWATER MANAGEMENT SYSTEM FROM CONSTRUCTION SITE RUNOFF. SC-740 6" (150 mm) INSPECTION PORT DETAIL CONCRETE SLAB 8" (200 mm) MIN THICKNESS * THE PART# 2712AG6IPKIT CAN BE USED TO ORDER ALL NECESSARY COMPONENTS FOR A SOLID LID INSPECTION PORT INSTALLATION 6" (150 mm) INSERTA TEE PART# 6P26FBSTIP* INSERTA TEE TO BE CENTERED ON CORRUGATION CREST FLEXSTORM CATCH IT PART# 6212NYFX WITH USE OF OPEN GRATE PAVEMENT CONCRETE COLLAR CONCRETE COLLAR NOT REQUIRED FOR UNPAVED APPLICATIONS 12" (300 mm) NYLOPLAST INLINE DRAIN BODY W/SOLID HINGED COVER OR GRATE PART# 2712AG6IP* SOLID COVER: 1299CGC* GRATE: 1299CGS 6" (150 mm) SDR35 PIPE SC-740 CHAMBER 18" (450 mm) MIN WIDTH 4 NOTES FOR CONSTRUCTION EQUIPMENT 1.STORMTECH SC-310 & SC-740 CHAMBERS SHALL BE INSTALLED IN ACCORDANCE WITH THE "STORMTECH SC-310/SC-740/DC-780 CONSTRUCTION GUIDE". 2.THE USE OF CONSTRUCTION EQUIPMENT OVER SC-310 & SC-740 CHAMBERS IS LIMITED: ·NO EQUIPMENT IS ALLOWED ON BARE CHAMBERS. ·NO RUBBER TIRED LOADERS, DUMP TRUCKS, OR EXCAVATORS ARE ALLOWED UNTIL PROPER FILL DEPTHS ARE REACHED IN ACCORDANCE WITH THE "STORMTECH SC-310/SC-740/DC-780 CONSTRUCTION GUIDE". ·WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT CAN BE FOUND IN THE "STORMTECH SC-310/SC-740/DC-780 CONSTRUCTION GUIDE". 3.FULL 36" (900 mm) OF STABILIZED COVER MATERIALS OVER THE CHAMBERS IS REQUIRED FOR DUMP TRUCK TRAVEL OR DUMPING. USE OF A DOZER TO PUSH EMBEDMENT STONE BETWEEN THE ROWS OF CHAMBERS MAY CAUSE DAMAGE TO THE CHAMBERS AND IS NOT AN ACCEPTABLE BACKFILL METHOD. ANY CHAMBERS DAMAGED BY THE "DUMP AND PUSH" METHOD ARE NOT COVERED UNDER THE STORMTECH STANDARD WARRANTY. CONTACT STORMTECH AT 1-888-892-2694 WITH ANY QUESTIONS ON INSTALLATION REQUIREMENTS OR WEIGHT LIMITS FOR CONSTRUCTION EQUIPMENT. ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-803 STORMWATER DETAILS TYPICAL SHRUB DECIDUOUS TREE PLANTING & STAKING PLAN TYPICAL GROUNDCOVER PLAN SECTION BIORETENTION BASIN ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-804 LANDSCAPE DETAILS BALLAST BASE ELEVATION SECTION A-A TEMPORARY CONSTRUCTION CHAIN LINK FENCE WITH BALLAST BASE DOUBLE GATE ELEVATION GATE PLAN 24' WIDE DOUBLE GATE CATCH BASIN W/ SILTATION SACK INLET PROTECTION PLAN VIEW SECTION A-A SIDE ELEVATION SECTION B-B STABILIZED CONSTRUCTION ENTRANCE PERSPECTIVE VIEW SECTION PERIMETER PROTECTION BARRIER PERSPECTIVE VIEW SECTION SILT FENCE DETAIL WITH WATTLES PERIMETER PROTECTION BARRIER · · · ARCHITECT CONSULTANT STAMP KEY PLAN SHEET TITLE PROJECT NUMBER: DRAWN BY: CHECKED BY: 160 FEDERAL STREET SALEM HISTORIC SCHOOLS NORTH SHORE COMMUNITY DEVELOPMENT COALITION, INC.218010.1 PES/BC SV MARK DATE DESCRIPTION2 Center Plaza, Suite 430 Boston, MA 02108 T: (617) 338-0063 F: (617) 338-6472 Civil Engineering Land Surveying Transportation Engineering Structural Engineering Planning GIS Green Infrastructure 02-13-2020 SITE PLAN REVIEW NITSCH PROJECT NO. 13928 04-28-2020 SITE PLAN RESUBMISSION 05-14-2020 SITE PLAN RESUBMISSION C-805 SOIL EROSION AND SEDIMENT CONTROL DETAILS