Loading...
9 WHEATLAND ST - BUILDING INSPECTION (2) >3 (4 - G �1 -7 -:5 AVg0-3 The Commonwealth of Massachusetts ° Board of Building Regulations and Standards CITY OF Massachusetts State Building Code,780 CMR SALEM Revised Mar 2011 Building Permit Application To Construct,Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Nu be Date pplie gill ding Official( nl N e) Sign ur ate SECTION 1:SITE INFORMATION _ 1 Property Address: 1.2 Assessors Map&Parcel Numbers l.l a Is this an accepted street?yes x no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(11) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.QL c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Check if yes❑ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner of Re rd: �YIC�h nv 2a. A I A Salem MAk 0Q10 Name(Print) City,State,ZIP ��LDOA$(arlpl5t GjR'1u5i5 {��_ �c�l»c�S� No.and Street Telephone marl Address SECTION 3:DESCRIPTION OF PROPOSED WORK (check all that apply) New Construction Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work: 5+VA p p DbJa- v0kk-aiG Solar ySFpyyls -61- c2E Ac4 SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: (Labor and Materials Official Use Only 1.Building $ 0 )o 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ 0 ❑Standard City/Town Application Fee 0' ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire -Suppression) $ Total All Fees: $ Check No. Check Amount: Cash Amount:_ 6.Total Project Cost: $ .� ❑Paid in Full ❑Outstanding Balance Due: �( �VIP[UI�778r1 -- -,'0s SECTION 5: CONSTRUCTION SERVICES 5.1Construction Supervisor License(CSL) 0 2_5 4 C8 1 2$ 9 �1 avve_s -=L�t?_I ryLa,r) License Number Exp ation ate Name of CSL Holder 2 I �ka�Y\ S� ^� List CSL Type(see below) U No.and Street �C" I Type Description S`cL us I k 7A OI9 Q W U Unrestricted Buildings u to 35,000 cu.ft.) City/1'0",Stas ZIP R Restricted 1&2 FamilyDwelling M Masonry RC RoofingCovering WS Window and Siding SF Solid Fuel Burning Appliances �1�51�J fll.QS Y1 0 S�0Lar� VIVIV��p'Qf I Insulation Telephone Email address COwI D Demolition 5.2 Registered Home Improvement Contractor(HIC) \1o/IV± Solar �evelopeY lLC I-'o�ra18 t ) HIC Registration Number Expiration Date HIC Com any Name or HIC R gistrant Name '-Ia3Pet ?,oD V� . rnaso0-Jr vtVln-Fs0hVr No.and Street Pt OYO 1?I- `64100!4 1$1305301Q5 Email address tam Ci /Town,State,ZIP Tele hone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........A No........... ❑ . SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize VI V 1✓1t Sfl ICL.I— to/acttt on my behalf, in all matters relative to work authorized by this building permit application. t Print O er's Name ame( rct rol1m(Rc dig. mre) ate SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in th' p ' tion is true and accurate to the best of my knowledge and understanding. V t OLr 2/2_&)4 Print O s r rind Agent's Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at wLv .mass. oe v/oca Information on the Construction Supervisor License can be found at www.mass. ovg /dns Z. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" CERTIFICATE OF LIABILITY INSURANCE oA,E/2013 YYY) 111co • THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy((es)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endomement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 vxONE Fax IN rt AIC Not: DENVER,CO 80202-5534 E11-ADDRESS:o ABn:Denwe.cerrequest@mamh.com,Fax:212.948.4381 INSURE S AFFORDING COVERAGE MAID# 462738-STND-GAWUE-13-14 INSURER A:Evanston Insurance Company 35378 INSURED INSURER B:National Union Fire Insurance Goof PA Vivint Solar,Inc. 4931 N 300 W INSURER C:New Hampshire Insurance Company 23841 Prow,UT 84604 INSURER D: W SURER E INSURER F COVERAGES CERTIFICATE NUMBER: SEA-002368030-06 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILTR TYPE OF INSURANCE O L UBR POLICYNUMBER MMMIUDDYEFF M�"DDfYYYY LIMITS A GENERAL LIABILITY 13PKGWED0274 11/01/2013 11/01/2014 EACH OCCURRENCE $ 1,654000 X COMMERCIAL GENERAL LIABILITY PIEM 50,000 PREMISES Ea occurrence $ CLAIMS-MADE F9 OCCUR - MED UP(Any one person) $ 5,000 PFR50NA1'.A ADV INJURY $ 1,000,000 GENERALAGGREGATE $ 2,000,000 GENL AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OPAGG $ 2,000,000 X POLICY PIPCTRP LOC $ B AUTOMOBILE LIABILITY 9701087 11/01/2013 11/01/2014 COMBINED SINGLE LIMIT 1 Ea weddem ,000,000 B X ANY AUTO 9701088 11/01/2013 11/01/2014 BODILY INJURY(Per person) S ALL OS SCHEDULED BODILY INJURY(Par accident $ AUTOS AUTOS ) X HIREDAUTOS X AUTOSNON-O PROPERTY acedemDAMAGE $ 8 A UMBRELLA LUM; X OCCUR 13EFXWE00088 11/0112013 11MV2014 EACH OCCURRENCE g 10,000,000 X EXCESS LUIB CLAIMS-MADE AGGREGATE $ 10,000,000 DELI RETENTION$ $ C WORKERS COMPENSATION 029342334; 029342335 11101n013 11101014 X I N,CSTATU- OTH. AND EMPLOYERS'LIABILITY C ANY PROPRIETOR/PARTNEWEXECUTIVE Y/N 029342336; 029342337 11/01/2013 11/01/2014 1,000,000 FR OFFICERIMEMBER EXCLUDED? Q N/A E.L.EACH ACCIDENT E C (Mandatory In NH) 029342338 11101/2013 11101n014 E.L.DISEASE-EA EMPLOYE E 1,000,000 R DESC yes,tlescribe under 1,000,000 RIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Errors B Omissions 8 13PKGW00029 11/01/2013 11/01/2014 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ANach ACORD 101,Additional RenarNa Schedule,K mom apace Is mqulmd) he Certificate Holder and others as defined in the written agreement ale included as additional insured where required by written contract with respect to General Liability.This insurance is primary and non- nt ibutory over any existing insurance and limited to liability arising out of the operators of the named insured and where required by written contract.Waiver of subrogation is applicable where required by written ntract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Mamh USA Inc. Kathleen M.Parsloe .{�x,((�.ic 1lt. fia,46— 01988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD t' ? C 021 C.ot¢ton, l�� s.9P .SdttPCSPd9ll BosPotMA ���14-2®1 7 44rww.mass.govIdia NVorkers' Compensation Insurance Affidavit: Builders/Contractors[Electriciaus/Plumbers Applicant Ianformation Please Print Legibly Name (Business/Organization/Individual): Vivint Sour Developer, LLC Address:4931 North 300 West City/State/Zip:Provo, UT 84604 Phone#:801-704-9389 Are you an employer? Check the appropriate box: Type of project(required): 1.0 I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ❑ New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.+ required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ i am a homeowner doing all work officers have exercised heir 11.❑ Plumbing repairs or additions No workers' myself. kers' cam right of exemption per MGL y [ P l2.❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' l3.❑ Other comp. insurance required.] *Any applicant that checks box#lk must also fih out the section below showing their workers'compensation policy information. r Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. !Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees, they must provide their workers'comp.policy number. d am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:New Hampshire Insurance Comany Policy# or Self-ins. Lic. #:029342228 Expiration Dat(e::1'1-01-14 Job Site Address: q wll(wj l m�-/' �� City/State/Zip:�,(lQM IMPA pw— Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL a 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. P do hereby cet under tlta paiM and penalties of perjury that the information provided above is true and correct. �/ 3 � Sign ature: %/ % Date Phone #: 801-70 9889 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1. Board of Health 2. Building Department 3. City/'Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone#: U&e cv c.�I%Gajjac (IjW4 Office of Consumer Affairs d Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. son 1 G 20ra-0511t Address Renewal Employment Lost Card Vlze U�Nn�mza�xuie�Ld�a�V�U[d1¢L�dGId t rice of Consumer Affairs&Business Regulation License or registration valid for individul use only ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation egistration: 170848 Type: 10 Park Plaza-Suite 5170 1/5/2016 Supplement Gerd Boston,MA 02116 VIVINT SOLAR DEVELOPER LLC. JAMES SHERMAN r 4931 NORTH 300 WEST � _— PROVO, UT 84604 Undersecretary Not valid without signature }�f Massachusetts -Department of Public Safety W Board of Building Regulations and Standards C)nstrurtion Supci"i isor License: CS-045254 --A c JAMES R WERMAN 1 81 MAIN ST SAUGUS MA 01406 r Expiration Commissioner 08/28/2014 2781 Fries Mill Road,Williamstown,NJ 08094 Tel: 856.770.4473; rdcipolla@verizon.net Vivint Solar February 26, 2014 24 Normac Road Woburn MA, 01801 Attn: Mr. Paul Greene, Operations Manager Re: Structural Assessment Report for Roof Mounted Photovoltaic (Solar)Panel Installations—Valenzuela Residence,9 Wheatland Street, Salem,MA AR# 3578827 Dear Paul: We are providing you with this structural assessment report of Vivint Solar's photovoltaic (solar) roof installations to be completed at the above referenced dwelling. The assessment criteria are based upon Vivint's recent dwelling site visit including roof framing photographs and field notes. We have also reviewed Vivint's PV Solar Permit Submittal, calculations, installation layouts and notes, PV 1.0 "Site Plan", PV 2.0 "Roof Plan", and PV 3.0, "Mounting Details". All were supplied for information on the proposed solar panels installation on the dwelling's roof framing members for our assessment summary. The dwelling is timber framed of older construction age with an"A" framed main roof, 4'- 3"+/- high, built from nominal 2" x 4" full cut dimensional lumber joists at 21" +/- o/c, typical. There is a low sloped attached rear roof assumed to be similarly framed and receiving solar panels. The maximum roof joist span length is 15' — 9" +/- with no reductions for collar ties supports. Two layers of roof shingles are assumed. Materials are assumed as minimum Hem-Fir #2 grade, conservatively (low allowable stresses), with standard construction components (better grade lumber may have been used). No collar ties are installed on the joists, below the 2" x 8" ridge beam in the main "A" roofs'/attic's full length, in panel installations areas, for roof reinforcing. There are 2" x 4" ridge beam supports at 30" to 62" o/c, the full length of roof posted down to framing below. The main attic and roof framing were mostly accessible by access panels at the site inspection and evaluation, so a complete assessment and confirmation of framing spacing, sizes and condition was able to be performed for this roof. The rear roof received a partial assessment due to lack of confirmed framing. No architectural drawings were available at the time of this report preparation. Refer to plans and documents prepared by Vivint for dwelling dimensions, locations and sizes of solar panel units. The roof framing members were reviewed and checked for their capacity of new loadings. A. CAPACITY OF EXISTING ROOF TO SUPPORT PROPOSED SOLAR PANELS: 1. Our assessment included using the proposed solar panels dead load that were given to us in the ZEP calculation sheets and the live and dead loads described below. Our review of the roof information shows that there are no visible undulations or unevenness, indicating that the roof framing members are not visibly overstressed or weakened by past heavy snow loads. Mr. Paul Greene February 26, 2014 Page 2 2. Given the dwelling's roof construction and condition, the existing roof joists' load carrying capacity will be able to carry the added dead and redistributed live loads from the new solar panels if installed correctly. The dwelling's roof members will also redistribute the snow live loads, and additional solar panels dead load to the adjacent framing members. These additional loads should not produce stresses beyond the allowable stress range for roof framing members assumed as Hem-Fir#2 materials. Considering the low roof slopes, array sizes; full/limited access to confirm roof joists' size, spacing, condition; posts and no collar ties, the panel supports shall be set/ attached to second joist for lateral installations over joists. No panel supports acin shall be greater than two(2)roof joist spaces, or 44" +/- o/c to be shown in the PV 2.0 Roof Layout plan(s). Note—Layout Array Drawings#I and#2 submitted for review, show this maximum panel support spacing, and need no spacing revisions. The panel supports shall be installed in staggered patterns to ensure the proper load distribution,and with no more than three supports placed on any single roof joist except at ends of layouts. These layouts can be used for permit submittals and installations, with the staggering of supports being done in the field. All panels shall be installed as shown on the layout plans, with 44"+/- o/c maximum support spacing, or two ioist spaces and staggered, to be shown in the final PV 2.0 Roof Layout plan(s), as stated above. Framing member sizes, spacing and condition must be properly verified by Vivint's installers, prior to any installations. Send any differing information to this engineer for review and approval, prior to continuing with any installations. 3. This assessment meets current Massachusetts Building Code, 81'Edition—Residential —Amendments to International Residential Code, (IRC), 2009 Edition, for one and two family dwellings. B. SOLAR PANEL ATTACHMENT TO ROOF STRUCTURE: I. The solar panels shall be mounted in accordance with the latest"ZEP Company's Code Compliant Installation Manual" found on the ZEP website and not included herein. No additional reinforcing requirements are required for these installations. However, if during solar panel installations, the roof framing members feel unstable, or show interior or exterior evidence of minor or excessive movement,then this engineer should be notified as soon as possible prior to proceeding with installations. 2. Vivint should notify the homeowners that long term build-up of accumulated snow in the event of extreme snowfall conditions, may produce some roof deflections. These deflections will be temporary in nature and will not affect the roof's structural integrity. The solar panels do not need to be cleared of such accumulated snow. C. WIND UPLIFT LOAD: F 1. Refer to attached ZEP calculation sheet for ASCEISEI 7-10 Minimum Design Loads Mr. Paul Greene February 26, 2014 Page 3 For Buildings and Other Structures, for wind speed at this location of 100 miles per hour* for Exposure Category `B", and 8 &23 degree roof slopes on dwelling's roof areas. Ground snow load is 40 p.s.f.* for Exposure `B",Zone 1 (per ASCEISEI 7- 10) of the roof's interior portion, and effective wind speed of 100 mph*, uplift is shown. 2. Total area subject to wind uplift is calculated for the Interior,Edge and Corner Zones. A maximum and user selected support(foot) spacing is shown for each location zone. D. PANEL ANCHORAGES: 1. Maximum allowable pullout per lag screw=235 #/inch from National Design Standards(NDS)timber construction specifications for Hem-Fir -North lumber (assumed). Using 4 lag screws, the pullout value is less than 235 #/inch of screw thread and OK. Considering the variable factors for the existing roof framing members, and installation tolerances, use a 2 ''/z"threaded depth with a minimum 5/16" lag screw per attachment points in roof joists ("rafters") components for panel anchor mounts. This should give a sufficient factor of safety. E. LIVE,DEAD AND SNOW LOADS: 1. Live load=40 p.s.f. ground snow load; 10 p.s.f. attic storage(trusses only) Dead Load= 10 p.s.f-roofing/framing; 5 p.s.f. - panels, mounting hardware Total Live Load=40 p.s.f.; Total Dead Load= 15 p.s.f. 2. These values are within acceptable limits of recognized industry standards for similar structures. The roof members will be able to sustain the solar panel attachments without damage, if installed in a workmanship like manner according to the above criteria. We have based our structural capacity determination on applicable building codes, professional engineering inspection and design experience, opinions and judgments. This report covers this dwelling's assessment for only the areas for solar panel installations that were made according to generally recognized structural analysis standards and procedures. The normal structural engineering industry standard of care utilized for this type of work was used during this report preparation. The assessments and recommendations in this report were reviewed to ensure a proper level of quality and uniformity. This report adheres to accepted State and National practices for current building code standards and can be used for construction purposes. If you have any questions or require further information,please do not hesitate to contact Respe ly sub e Russell �. Cipolla, gist e o F Kjl/llY/1 Structural Engineer, Owner t cy Mass. License No. EN-47478-5 RUSSELLD. CIPOLLA STRUCTURAL * or as specified locally per the State Board of Bldg. Regs. and Stds., whichever go No.47478 RDC/rdc tsTEP`�°��`Q ass/ONALE���'\ Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Kristen Valenzuela Project Address: 9 Wheatland St,Salem MA A.System Description: The array consists of a 4.75 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There arc(19) 250-watt modules and (19)215-watt micro-inverters,mounted on the back of each PV module.The array includes(2)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Zep Solar. B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4 OF (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Zep Solar b.Product Name: ZS Comp c.Total Weight of PV Modules and mounting hardware: 817 Ibs d.Total number of attachment points: 33 e.Weight per attachment point: 24.75 Ibs/square foot f.Maximum spacing between attachment points: *See attached Zep engineering talcs g.Total surface area of PV array: 334.59 square feet h.Array pounds per square foot: 2.44 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (13)modules,(21)attachments 26.61 pounds per square foot -Roof section 2: (6)modules,(12)attachments 21.5 pounds per square foot vivW. solar 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 250-PA05.18 19 modules Module Specs Pmax-nominal maximum power at STC - 250 watts Vmp-rated voltage at maximum power - 30.3 volts Voe-rated open-circuit voltage - 37.6 volts Imp-rated current at maximum power - 8.27 amps Ise-rate short circuit current - 8.85 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-2LL-S22 19 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 1. Input Data (DC in) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 10 modules/inverters (15) amp breaker PV circuit 2 - 9 modules/inverters (15)amp breaker vivint. solar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 9 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(B) PV circuit continuous current rating 11.25 amps 2.Overcurrent protection device rating PV circuit continuous current rating 11.25 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4 cC (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Table 310.15(B)(3)(c) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.7VF) 71% 2011 NBC Table 310.15(8)(2)(a) Adjusted PV circuit continuous current 15.8 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 80% 2011 NEC Table 310.15(B)(3)(a) Final Adjusted PV circuit continuous current 19.8 amps Total derated ampacity,for PV circuit 19.8 amps Conductors (tag2 on 1-line)must be rated for a minimum of 19.8 amps THWN-2(90°C) #14AWG conductor is rated for 25 amps (Use#14AWG or larger) 2011 NEC Table 310.15(B)(16) 4.Voltage drop (keep below 3%total) 2 parts. 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.18% The largest number of micro-inverters in a row in the entire array is 6 inCircuit 2.According to manufacturer's specifications this equals a voltage drop of 0.18%. 2.AC conductor voltage drop: =I x R x D (+240 x 100 to convert to percent) _ (Nominal current of largest circuit)x (Resistance of#14AWG copper)x(Total wire run) Total system voltage drop: # vivant. solar 2/2512014 3578827 roof 1-Zepulator ZepSolar Engineering Calculations 3578827 roof 1 Name: Street Address:9 Wheatland St. Email: Suite/PO#: Phone: City,Slate,Zip:Salem,Massachusetts 01970 Country:United States System Details Module Manufacturer Trina Solar Mounting System Zap Solar PV Module TSW250-PA05.18 Manufacturer Quantity of PV Modules 13 Mounting System Type ZS Comp Array Size (kW) 3.250 Roof type Composition Shingle Attachment Type Comp Mount,Type C Module-level Enphase Energy-M215-Z electronics http:/Aw .zepulator.con✓pro'1 is/45650/summar en ineerin� 9 9_wint 1/4 2/25I2014 3578827 roof 1-Zepulator Engineering Calculations Design Variables Description (Symbol) Value Unit Module Orientation Portrait Module Weight 44.8 Ibs Average Roof Height(h) 30.0 ft Least Horizontal Dimension(Ihd) 25.0 ft Edge and Corner Dimension"a" 3.0 ft Roof Slope(0) 23.0 deg Rafter(f russ spacing 21.0 in Rafter/Truss dimension Min.nominal framing member depth of 4" Basic Wind Speed(V) 110 mph E)posure Category B Ground Snow Load(P9) 40 psf Risk Category I Topographic Factor(Kit) 1.0 Thermal Factor for Snow Load(Ct) 1.2 E)posure Factor for Snow Load(Ce) 0.9 Effective wind Area 10 ft2 Snow Load Calculations (Using calculation procedure of ASCE 7-10 Chapter 7) Description(Symbol) Interior Edge Corner Unit Flat Roof Snow Load(Pt) 24.2 24.2 24.2 psf Slope Factor(Cs) 0.9 0.9 0.9 Roof Snow Load 20.7 20.7 20.7 psf Wind Pressure Calculations (Using simplified procedure of ASCE 7-10 Chapter 27) Description(Symbol) Interior Edge Corner Unit Net Design Wind Pressure uplift(P,et30_up) -19.9 -34.7 -51.3 psf Net Design Wind Pressure downforce(Pnet3o down) 12.5 12.5 12.5 psf http:/AA , .zepulata.con✓projects/46650/suniroymgineering_prird 2/4 2/25/2014 3578627 roof 1-Zepulatcr Adjustment Factor for Height and Exposure Category(A) 1.0 1.0 1.0 Design Wind Pressure uplift(Wup) -19.9 -34.7 -51.3 psf Design Wind Pressure downforce(W&wn) 16.0 16.0 16.0 psf ASD Load Combinations (Using calculation procedure of ASCE 7-10 Section 2.4) Description (Symbol) Interior Edge Corner Unit Dead Load(D) 2.5 2.5 2.5 psf Snow Load(S) 19.0 19.0 19.0 psf Load Combination 1 (D+0.75"(0.6"Wdowu)+0.75'S) 22.7 22.7 22.7 psf Load Combination 2(D+0.6Vdown) 11.9 11.9 11.9 psf Load Combination 3(D+S) 19.9 19.9 19.9 psf Uplift Design Load(0.6'D+0.6'Wup) -10.5 -19.4 -29.4 psf Maximum Absolute Design Load(Pabs) 22.7 22.7 22.7 psf Spacing Calculations Description(Symbol) Interior Edge Corner Unit Max allowable spacing between attachments 72.0 72.0 49.0 in User selected spacing between attachments given a rafter/truss spacing of 21.0 in 42.0 63.0 42.0 in Max cantilever from attachments to perimeter of PV array 24.0 24.0 16.0 in Distributed Weight and Weight per Attachment Point Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)) Description(Symbol) Value Unit Weight of Modules 582.4 Ibs Weight of Mounting System 51.13 Ibs Total System Weight 633.53 Ibs Total Array Area 228.97 ftZ Distributed Weight 2.77 psf Total Number of Attachments 21 Weight per Attachment Point 30.17 psf http:/Aw .zepulator.coNprojects/46650/summa Vwgineering_print 3/4 2/2512014 3578827 root 1-Zepulator http:/Aw .zepulatu.cortVprcjmts/46650/sunmm ywgineering_print 4/4 2/2512014 3578827 roof 2-Zepulator ZepSolar Engineering Calculations 3578827 roof 2 Name: Street Address:9 Wheatland St. Email: Suite/PO#: Phone: City,Slate,Zip:Salem,Massachusetts 01970 Country:United States System Details Module Manufacturer Trina Solar Mounting System Zep Solar PV Module TSM-250-PA05.18 Manufacturer Quantity of PV Modules 6 Mounting System Type ZS Comp Array Size (kW) 1.500 Roof type Composition Shingle Attachment Type Comp Mount,Type C Module-level Enphase Energy-M21 5-Z electronics http:/Av .zepulator.conitprcjmts/46652JsummarVengineering-print 1/4 2/25t2014 3578827 roof 2-Zepulator Engineering Calculations Design Variables Description (Symbol) Value Unit Module Orientation Landscape Module Weight 44.8 Ibs Average Roof Height(h) 30.0 ft Least Horizontal Dimension(Ihd) 25.0 ft Edge and Corner Dimension"a" 3.0 ft Roof Slope(0) 8.0 deg Rafter/Truss spacing 21.0 in Rafter/Truss dimension Min.nominal framing member depth of 4" Basic Wind Speed(V) 110 mph Exposure Category B Ground Snow Load(Pg) 40 psf Risk Category I Topographic Factor(Kit) 1.0 Thermal Factor for Snow Load(Ct) 1.2 Exposure Factor for Snow Load(Ce) 0.9 Effective wind Area 10 ft2 Snow Load Calculations (Using calculation procedure of ASCE 7-10 Chapter 7) Description(Symbol) Interior Edge Corner Unit Flat Roof Snow Load(Pf) 24.2 24.2 24.2 psf Slope Factor(C.) 1.0 1.0 1.0 Roof Snow Load 24.2 24.2 24.2 psf Wind Pressure Calculations (Using simplified procedure of ASCE 7-10 Chapter 27) Description (Symbol) Interior Edge Corner Unit Net Design Wind Pressure uplift(Pnet30_up) -19.9 -34.7 -51.3 psf Net Design Wind Pressure dovmforce(Pnet30 down) 12.5 12.5 12.5 psf http://wow.zepulator.condFrojects/46652/surrmiaryfengineeringyrint 24 2I25/2014 3578827 roof 2-Zepulator Adjustment Factor for Height and Exposure Category(A) 1.0 1.0 1.0 Design Wind Pressure uplift(WuP) -19.9 -34.7 -51.3 psf Design Wind Pressure downforce(Wdown) 16.0 16.0 16.0 psf ASD Load Combinations (Using calculation procedure of ASCE 7-10 Section 2.4) Description (Symbol) Interior Edge Corner Unit Dead Load(D) 2.5 2.5 2.5 psf Snow Load(S) 24.0 24.0 24.0 psf Load Combination 1 (D+0.75'(0.8'Wdown)+0.75"S) 27.5 27.5 27.5 psf Load Combination 2(D+0.6'Wdown) 12.1 12.1 12.1 psf Load Combination 3(D+S) 26.2 26.2 26.2 psf Uplift Design Load(0.6'D+0.6'WPp) -10.4 -19.3 -29.3 psf Maximum Absolute Design Load(Pab) 27.5 27.5 27.5 psf Spacing Calculations Description(Symbol) Interior Edge Corner Unit Max allowable spacing between attachments 72.0 72.0 72.0 in User selected spacing between attachments given a rafter/truss spacing of 21.0 in 42.0 63.0 63.0 in Max cantilever from attachments to perimeter of PV array 24.0 24.0 24.0 in Distributed Weight and Weight per Attachment Point Calculations (In conformance with Solar ABC's Expedited Permit Process for PV System (EPP)) Description(Symbol) Value Unit Weight of Modules 268.8 Ibs Weight of Mounting System 25.75 Ibs Total System Weight 294.55 Ibs Total Array Area 105.68 ft2 Distributed Weight 2.79 psf Total Number of Attachments 12 Weight per Attachment Point 24.55 psf http:/A w ..zepulator.con/projects/46652]summa Vy gineering_print 3/4 2/25/2014 3578827 roof 2-Zepulator http./Aw .zepulator.cortVprojects/46652/summa Vl gineerirg_print 414 m U C N m "ate F— �tE� N PV SYSTEM SIZE: I Imo 4.75 kW DC L I I Q I I f^ I I � •e r I I •� E 65"OF 1°PVC CONDUIT I J FROM JUNCTION BOX TO ELEC PANEL I I 19)Tnna Solar TSM-250 PA05.18 MODULES WITH A g m Enohasa M21560-21-1--S2x-ZC MICRPINVERTER ¢ MOUNTED ON THE BACK OF EACH MODULE O f I I s w i m z � a � � E rcKvwi > m z m JUNCTION BOXATTACHED T U z ARRAY USING ZEP ZS-GAB TO I I ¢ F e3e KEEP JUNCTION BOX OFF ROOF i i o V INTERCONNECTION POINT, SHEET LOCKABLE DISCONNECT SWITCH, NAME: ANSI METER LOCATION, B UTILITY METER LOCATION W Z a 9 Wheatland St, Salem MA 01970 SHEET NUMBER: PV SYSTEM SITE PLAN o SCALE: 3/32"= V-0" > 0- 00 Z1 og0 y�0 iN ?n �O a> J y mm vz .a K m MIN m A 3 3 OA _, Ty Ntt n x 0< On M p M n m= NZi II M U 2 n Qy, m 0 yY yN.M 0 m3 cn N , n 65 N n D � r C m rn M m O O in 6�//� O/Z m r m D m A Z c2 Di NSTALLER:VIVINTSOLAR Valenzuela Residence P\/ o m y ROOF 7 y MA LICENSE MAHIC 1708484044129 Salem,MA 01970 V L PLAN DRAWN BY:Jerry S1 AR 3578B27 Last Modified 2/2512014 UTILITY ACCOUNT NUMBER 7562751005 m U C b 1 MOUNTING rn m w PV3.0 DETAIL 'mEZ STEEL Bi;STAINLESS Z LEVELING FOOT I23LF SiEELM 9.:TOROVE=t631 fl{pa, M a~ COMP MOUNT(ZSCMA) N 0 WAGNER PACKAGED A, Q WATERPROOFING T WRM COMP MOUNT N PV MODULE,TYP.MOUNT AS NEEDED c TO RAFTERS OF COMP. SHINGLE ROOF,PARALLEL PC WITH PLANE OF ROOF cu PV ARRAY TYP. ELEVATION SIUFB�TAINL SSUIEMININUM STEEL LAO Z STAINLESS STEELLAG SCREW C TORQUE=13i3 fl{pa, cu NOT TO SCALE _ V/ (LEVELING FOOT ON COMP MOUNT " PERMITTED LEVEUNc NOT TO SCALE Y' FOOT SPACING •V`GJ ry LEVELING FOOT RZ FIU I�1 FRAMING BELOW SIR r DASXED FOR CLARITY II ZEP COMPATIBLE P r PV MODULE INTERLOCK n C J r m m I I I I 0 7 SC moli. v K Z 0 I LPNTILEVER=V3 L=PERMIRE°SPACING j R L56EE CODE COMPLIANE LETTR FOR ALLOWABLE SPACING OTOVCLTAIL MODULEuJ W W WI Ib I4 I I I I I HTBWGINTERLOGK SHEET LEVELING FOOT(ZSiFB) INTERLOCK GCMI-B) NAME: ROOF FRAMING LEVELING FO°T(Z&LFBI ~ N I Z J I 0 UU W LATER OLKa3-ILB) FOOT "LAG IPV SYSTEM MOUNT DETAIL $HEEEET❑ FOOT SPACING NUM( SCALE:3I0"=1'-0' C)MODULES IN PORTRAIT/LANDSCAPE M NOT TO SCALE - n a L Inverter Ratings(Guide Section 4) Iol MANMMN Enphase M215K(LOL-Stri MODULE DETAIL Max DC Vat Feang 45 Vass O Conduit and Conductor Schedule (..) Max Pourer®40-C 215 Wafts Tap Deectlplon Wire Gauge «a Conaoctnrs nal Tro• Cal allor Nnminel An Vall 210 Von. 1 Gnpnase engage raMe-Tri 12 AWG 4 HIA-Free Ar WA-Fora Ar III-♦ Trials Solar TSM-250 PA05.16 Max AC Cur,enl 0.9 Ain, 1 Sere Coppar Ground IEGCIGECI 6AWG 1 WA-Free A, N/A-Free Ar y/ an SOLARMODULE Max GCPG Rating 20 A,nps 2 THWN-2 10 AWG 6 PVC ft'-1 Max Number of PanalYCittuil 17 2 THWN-2-Ground 8AWG 1 PVC 0'-1•� ] THWN-2 BAWD ] PVC 0'-1 W r �p NOTES FOR INVERTER CIRCUITS(Guide Section ] Troyl-Ground aAND 1 PVC oilien B and BI: m 1.)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS m¢f PV Module Ratings Q STC(Guide Section 5) � SWITCH MEET THEREQUIREMENTS? 250 PA05.18 r Moral Meke44otlel Tons Solar T9M- uE Enphase M21S61)2LL-52x-ZC Max power-poim Current(Imp) 7,89 Amps 3vz MICRO-INVERTER AT 2.)IF GENERATION METER REQUIRED.DOES THIS METER Max power-Point Voters p/mp) 30.4 Volts jp1NO EACH MODULE,ATTACHED SOCKET MEET THE REQUIREMENTS? Open-Cinuit Voltage(Voc) 37.2 Volts WITH ZEP HARDWARE YES NO XNA shorbCinait Current(Ise) 8.37 Amps N 3)SIZE PHOTOVOLTAIC POWER SOURCE(DC)CONDUCTORS Max Series Fees(OCPD) 15 Amps C BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Norman Pover at STC(Pmal 240 Watts RATING AT DISCONNECT. Maximum System Voltage 1000(IEC)1600(111 j 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Vol,Temporal CidefSdent \ #6 BARE CU GROUND 7-� TO INVERTER OCPD AMPERE RATING(Sao Guide Section 9). / (GROUNDING MODULE v S)TOTALOF 2 INVERTER OCPD(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Gold.Isadlonfi antl B antl Appendix DO, S INVERTER) PV CIRCUIT.ODES TOTAL SUPPLY BREAKERS COMPLY I WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient territorial based on ASHRAE minimum mean extreme NEC 690.64(a)(2)(a)? XYES NO on,bulb temperature for ASHRAE location most similar to Installation location: -19°C MICROINVERTER CONNECTION , Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb l TO ENGAGE TRUNK CABLE temperature for ASHRAE location most similar to installation location: 39°C l '� Sign for inverter OCPD and AC Disconnect 3.)2005 ASHRAE kn C damentals 2%design temperatures do not exceed 47°C in the United States(Palm Springs,CA is 44.1°0),For less than 9 current-carrying conductors ul Solar PV System AC Point of Connection in mof-mounted sunlit¢ooduit at least 0.5-above hoof and using the outdoor design ACONput Current I 17.100000 Amps temperature of47°C or less(all p/United Stales). J{�• Nominal AC Voltage I 2Xml Volta a.)12 AWG Sol conductors are generally acceptable for modules With Ise of 7.68 Amps •1r < or less When preferred by a 12-Amp or smaller fuse. THIS PANEL FED BY MULTIPLE SOURCES b)10 AWG,90°C condudme are generally acceptable for modules With Ise of 9.6 Amps (UTILITY ANp SOLAR) or less when vouteeftedb a15-Am or smeller fuse. •� •� 15 15 re PV CIRCUIT 1: 10 MODULES/PARALLEL ad adce 10 - POINT OF DELIVERY 5 m orm AND INTERCONNECTION y a 1 ¢ J` • • • J` f 2 m S m ¢ > od a ar W —T VISIBLE/LOCKABLE Ii: a m COMBINER SREC/ANSI 'KNIFE'A/C aft ad ad aft PV CIRCUIT 2: 9 MODULES/PARALLEL 1 PANEL METER DISCONNECT aZi E 1.0 1sor� z = o Q • • • O O SHEET 5A NAME: tsA � J` • • • ___ OJUNCTO 30AZJ 0 MV2�,_2S Siemens t 240V/150A#LNF222R _ LOAD-CENTER SHEET E?0 60A/240V NUMBERLE UNFUSED E 1.0 GROUND SPLICE NEMA3 p NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR LU y_ m N m A O O zm p C 0 cz O N N mx D 0m 0 0 m o 0 N ZEn y �J O Z N z 0 j 0 m m rr, m N ia� m 1FiY Y f. ]I a4. 0 v c m N D y W N C z O C A N zN zN INSTALLER:VMNTSOLAR w. •M'r ''Jn}�r Valenzuela Residence 3m DESIGN �^ INSTALLER NUMBER:1.877.404.4729 V O V aY YY Co PV 2.0 p" LOGIC my MA LICENSE MARIC 1T0848 v u• J� / Salem MA 01970 l St DRAWN BY:Jerry SI AR 35781 Last Modified:2/25/2014 UTILITY ACCOUNT NUMBER:7562751005