STATHERS_PROP_Wed_Jan_4_2023_15-20-39 ------—-------
D11
R PQ, Y
HEATINGit-CHANICAL
NI, & AIR
C 0 I T I O N I N G fi)
InvLntedforlife GOOLING A NRATING
3 Milton Way Georgetown I MA 101833
0 1,b I
LyylhGWTR
Name: MICHELLE STATHERS Proposal#:
16 RIVER ST.
Site Address! 11301202022074608-3. Date. 01/10/2022
Billing Address: 3.6 RIVER ST.City: SALEM Consultant; ALLAN BERRY
City: SALEM
State; MIA State: MIA Email: allan@berrYrnechanical.com
Cell Phone:Phone: (860) 806-3602 ZIP Code: 01970 Homeowner Email:M ICHELLE.STATHERSOGMAIL.COM
(978)352-5500
—Zone 1
M574..-NDOOR MITSU...ENSER
SY5ten, Investment
�Investment Type:Cash/Check
Base System
Optional items Total $6602.53
Discount Total(Before Any Rebate) $0.00
j System Total b,Q)0.2 E5
e�� Initial Investment $5942.27
Balance $0
NET INVESTMENT AFTER DISCOUNTS $5942.27$5942.27
Discounts
ON LINE DISCOUNT
$660.25
By signing this agreement I acknowledge that I have read and
understand each page, including the terms and conditions. Representative: Date:
Custom Date:
Approved By: Date:
ERRY
S7izqd4 d I. Merv' MECHANICAL BOSCH &MWI
HEATING & AIR Invented for
Co NDITIONING co
3 Milton Way Georgetown I MA 101833
Where Your comfort is our Business
Name: MICHELLE STATHERS Proposal#: R301102022074608-1 Date: 01/10/2022
Component In Base System Investment Inclusions
Qty Model# Description
MITSUBISHI MSZ-FS9NA INDOOR HEAD W/ADVANCED • EQUIPMENT PAD FOR OUTDOOR UNIT
2 MSZ-FS09NA-U1 • COPPER REFRIGERANT LINES
i-SEE SENSOR DOUBLE VEIN LOUVERS • COMPLETE SYSTEM START UP AND CHECK
MITSUBISHI MUZ-FS09NAH 9000 BTU OUTDOOR • ENSURE PROPER AMOUNT OF
1 MUZ-FS09NA-U1 CONDENSER HYPER HEAT WITH OUT DRAIN PAN REFRIGERANT FOR AC OR HP
HEATER. • ENSURE PROPER CONDENSATE
- WARRANTY: I YEAR
INSTALL DUCTLESS SPLIT INDOOR AND OUT DOOR FROM BERRY MECHANICAL PARTS&LABOR
1 INSTALLDUCTLESS25FTLIN UNIT. PIPE IN START UP AND CHECK OUT. GROUND • MITSUBISHI DIAMOND CONTRACTOR ONLY
EAR FLOOR UP TO 25 LINEAR FEET OF PIPE. INCLUDES PIPE LTD WARRANTY(12)YEAR ON
FROM INDOOR TO OUTDOOR UNIT AND DRAIN. COMPRESSOR(12)ON PARTS
WIRE 1/2 INCH OF CABLE WITH 3 CONDUTORS AND A • QUOTED PRICING IN THIS PROPOSAL IS
1 1/21NCHUF-4COND25 GROUND FROM DUCT LESS AIR HANDLER TO GOOD FOR 30 DAYS AFTER
RECEIPT
CONDENSER UP TO 25 FEET • EVACUATE REFRIGERANT SYSTEM
2 20LBBAG-CRUSHEDSTONE 20 POUND BAG OF CRUSHED STONE • PROVIDE MECHANICAL/SHEETMEATAL
1 36X40 ULTRALITE PAD
CLADLITE PRE-CAST PAD FOR CONDENSERS HEAVY PERMIT
DUTY POUR OVER RESISTS CRACKING 36x40
2 LD-92 STRAIGHT FORTRESS COVERING 92 STRAIGHT PEICE 8FT. Exclusions
LENGTH • ELECTRICAL POWER WIRNG
1 LJ-92 COUPLER FORTRESS COVERING 92 COUPLING • ELECTRICAL PERMIT
1 LW-92 WALL INLET FORTRESS COVERING 92 WALL INLET
QUICKSLING MINISPLIT OUTDOOR UNIT STAND 18
1 QSMS1801 INCH ELEV-17 INCH MAX BOLT WIDTH SINGLE HEAD
CONDENSER
6 SALEMMARESD- SALEM MA RESIDENTIAL SHEETMETAL/MECH PERMIT
MECHMETAL 7.00 PER 1000.00
Installation Instructions
HANG A MITSUBISHI FS 9,000 HEAD ON THE SIDE WALL NEXT TO THE DOOR. RUN THE LINE SET,THE DRAIN,AND THE 14/3 WIRE OUT
UNDER FORTRESS COVER THROUGH THE DECK THEN DOWN UNDER THE DECK. LEVEL THE GROUND WITH CRUSHED STONE AND PLACE A
PAD DOWN.SIT A STAND ON THE PAD AND THE CONDENSER ON THE STAND. CONNECT THE LINE SET AND THE 14/3 WIRE.TERMINATE
THE DRAIN UNDER THE DECK. PRESSURE TEST THEN EVACUATE,AND CHARGE. (CUSTOMERS ELECTRICAIN TO POWER WIRE THE
CONDENSER AND ADD NEEDED OUTLET PER CODE. START UP AND CHECK OUT.
By signing this agreement I acknowledge that I have read and
understand each page, including the terms and conditions. Representative: Date:
Customer: Date: Approved By: Date:
MUNd •