Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
40 CIRCLE HILL ROAD - BUILDING JACKET
� �f� ���f �,i � �.� 5 m Citv of Salem 120 Washington St,3rd Floor Salem,MA 01970(978)745-9595 x5641 Return card to Building Division for Certificate of Occupancy lug Structure CITY OF SALEM BUILDING PERMIT PERMIT TO BE POSTED IN THE WINDOW r t Excavation ^ Footing INSPECTION RECORD Foundation Framing (a MechanNA Insulation $ t INSPECTION: BY DATE Chimney/Smoke Chamber - Final e d J fw Plumbing/Gas RougVIdrhbir,Lq 0, . tjA-1 I , , Rough:Gas cc✓✓�7 11 rt Final /Q t Electrical Service Rough // Final O 01 Fire Department Prelimina Final /Cl Prf"9 Health Department eliminary Final Commonwealth of Massachusetts I 3a City of Salem uv 120 Washington St,3rd Floor Salem,MA 01970(978)745-9595 x5641 { Return card to Building Division for Certificate of Occupancy Permit No. 8-17-372 PERMIT TO BUILD FEE PAID: $1,400.00 DATE ISSUED: 5/12/2017 This certifies that PEZZULO DOMINIC A PEZZULO ERIN R has permission to erect, alter, or demolish a building 40 CIRCLE HILL ROAD Map/Lot: 90255-0 as follows: New Construction - 1-2 Family NEW CONSTRUCTION (2300^SF) SINGLE FAMILY HOME. Contractor Name: ROSS DIMAMBRO , DBA: Contractor License No: CS-107473 �7 � y 5/12/2017 Building Official Date This permit shall be deemed abandoned and invalid unless the work authorized by this permit is commenced within six months after issuance.The Building Official may grant one or more extensions not to exceed six months each upon written request. All work authorized by this permit shall conform to the approved application and the approved construction documents for which this permit has been granted. All construction,alterations and changes of use of any building and structures shall be in compliance with the local zoning by-laws and codes. This permit shall be displayed in a location clearly visible from access street or road and shall be maintained open for public inspection for the entire duration of the work until the completion of the same. The Certificate of Occupancy will not be issued until all applicable signatures by the Building and Fire Officials are provided on this permit. HIC#: "Persons contracting with unregistered contractors do not have access to the guaranty fund"(as set forth in MGL c.142A). Restrictions: Building plans are to be available on site. All Permit Cards are the property of the PROPERTY OWNER. Certificate Number: B-17-372 Permit Number: B-17-372 Commonwealth of Massachusetts City of Salem This is to Certify that the Pot Land Building located at ......................................................................... ...................................................................................:....................... Building Type .............................................................40 CIRCLE HILL ROAD.-.................................................................. in the .....................................City of Salem............................................... ................................................. Address Town/City Name IS HEREBY GRANTED A PERMANENT CERTIFICATE OF OCCUPANCY New Single Family Home This Permit is granted in conformity with the Statutes and Ordinances relating thereto, and expires ............................Not APPticabte............................. unless sooner suspended or revoked. Expiration Date Issued On: Monday, October 16, 2017 ,p �110�/ /1p� \ 00 \N \ -113' v oOs N \ O F` o M M I O LOT 1 \� S 87'36'03" W / AREA = 19,448 t S.F. 24.74 / �F\ LEGEND �TRANSFO"ER oG WATER SHUT OFF ` w GAS SHUT OFF —S—S— SEWER LINE —E—R— UNDERGROUND ELECTRIC ♦� 0�' —G—G— GAS LINE 5k _ —W—W— WATER LINE at q'b S 63 � —C—C— UNDERGROUND CABLE LOT 2 P1HOFM'yG 9 O \^ ' GAILL. m SMITH J AS BUILT PLAN j 40 CIRCLE HILL ROAD, SALEM S°l SCALE 1 " = 30' OCTOBER 18, 2017 NORTH SHORE SURVEY CORP. 14 BROWN STREET, SALEM, MA 978-744-4800 #1567 �jot ZONING DISTRICT: Ri 1 A „ m \1 �a•��`# "p v I'p• RfaIRPdR A li P R� i IYMIWM LOr IhFA IS=S L \rL '♦' .3. n4 -4 1 -. ♦. .. PR DAI LOT AREA 4 ,• n n REA DMQING, IS.fLO SF � 3 \ / \ NHIWMLOT`NIH: IN RR .1. , _e .. .• y •. / ,y `\ y •.. \ \ (MEASURE)AT iR(Wi YIN SffBAIX) NN(MVY LOT CO"fRACE: ]a2 aa. 1 0.., P aaa \ ( (Au 9unar14s) 4 6 Yn ", - yH � / NNIYUY FAWi YIRp: IS iF£r MNINUM SCE YARD: 10 FEET '. •4 1. 1, /\ \MINIMUM BEAR YARD: ]a iFFE MANIMUM BLDG HpCHi: JS FEET (ET>=T1 MAOMUM BURG HEIGHT 2.5 .4 1 - F,/✓' 1 �.4 +�\qa (STORIESI ae /� d + MA%IMUM FENCE HpGHi: p FEET yVP GJUB'Ci MINIMUM olsrnxaE .w FEET 1 ..♦. ��. I r enLOEN eulLvxcs / e .,..✓ FOS 1�'I �/n ® - ON LOT: ITE l0 a o L N _ _- �� III \ A .fy�' LOOMS PI.,W FROM LOCUS " � ,nrHx Go w ' � o �I I SALEM CIS O 5 F• _.. L- I 20a e N- LEGEND E—cp ' CATCH BAS \/ _ .®'. H 0 n 1 / 'END WALL Z - - f Q / ( ///// .0o- R � 1RMl 9 .� - t .Z„3 MAIMAf£YANIQE /// 2 \ y —J�aRMN PIPE �12•D� W / { // / \' \ 10+ �,i fy� — - _ —- TBI TO BE YflaFlpl By TAE SITE -"`� .♦ I ✓ CONTRACTOR PROR TO CONSTRUCTOR FOR LOCATION, _ ? SUE.Ru Aro InwRr ELEVATIONS __ ` 111• ` �. M M BE REMOVED TR TO REMAIN g 111HAWNCAP RAMP ��MAX.BLOPE�&DIET, co PER MB SPE[5 O Q,IlVilll IJ .. t \ a � MCMnGRANITE Iw RBND wM�BG 9NMMOJS CUBING EM EDGE OF PAVEMENT(NO CU RBING) - � V 'I III y - xc 3 V UW V .T �+• ry L ELECTRIC �ELF ON ME(IBV) RATES NAE(TBR —M,4 F`7 / - '+4p�.n1'� 7� -;2 o d" RATES TATE(Tev)'I yt i9,571tSF __ _ 4 ,„ „W NT TINEwl P♦j \ =SENIOR ME(TBV) -CGS 1 +. PfLIX.11E � SEMER MANHOLE SIRIICTURE. • OMERNED ,ME _ -TAB, / � .O LasSRS UTutt POLE R, \\\\// _S aR wTHDur sTRECT IxalT _ // \ I 1 I C FIFE MBHFD FLOOR EIE.. U r /'_. ' (11 J RBF F1 NO TNSELET[IT�F�IEVAnM / V Y •: \1 ,S� A�-'. ExSTINC TREE r a+) is J5J =PRINTEDixPCurn O SPar' PER AcnI4 w TKE-GGNuvAw 'RT.T BExp1MAP1(B FOR W / /V! \ \ `i �G MMIR sERncAi CORNET CONTROL J 0 \J Q / CONTOJPB OF EWAL EIEVATM-7Z-_"' h. V.\ \ wMuw FORCE sF rnT(Tev)-Fu_ E ' ¢¢¢ S ��/✓/i I' F"e.-tzt z - IELECTRIC.-�,y``4 \ N 1{\I 11 wsTEF GRANITEBOUND SE GRANITE eouxD s(O $� ! #2 LSI v I I AIRW CONa EPS (ax CONCRETE PAD) ��\ ./ l II 1 { c.sws CON�G�SiEPS E0 1 ;� J \. \o.o+ 1 1 I S conD CONCRETE STEAM. / 20.593iSF SPH. ,HALT SIDEwAI% MB AS O. PR FF'P.=120.'2 \ P.1 GAS PROPANE TANK \ / // / - cA9 unE(TBI GAS DATE VALSE(TBV) O I \ �/ / / // ♦ GAS NETFR(1BV) 1 A %LI IOMNG DISTRICT SNE E IBMG PR)PFAIY ME NUIAIMNC PMBIG Pfi6ERIY LNE I - SETBACK JNF. SID NIS\ P�o.no' d # PRELIMINARY 3 ,� RE11"2 \ / 17,111tSITE PLAN SF ;r �� 4, C1 o r , ; SHOWING LAND SUBDIVISION h, 0 ��� \R I= 2� (TWO ADDITIONAL LOTS) / / r v q ` N 40 Circle Hill Road \3j it „.{!�o° o° Y ,R- / $ ?f E GENERAL NOTE � � 5 N`� / 4) \ Salem, Massachusetts a i LOCUS IS W ON SALEM ASSESSOR MAP B,LOT 255. THE LAND Is PRESENTLY S MIS N O H ! ,( �u / (SCAue-CAowTx) LA N &IIFLOOOPUDINM THE ROYAL COMMUNITY AREA IS D5,48B31 LOCUS DOES NOT \ O x ry �GJq ` 1 \ Date: NoVeNIber 13, 2007 ReAsed. January 15, 2008 E Y]ST M1NIN A FENA ZONE A Fll%IJPWN PER FIRM cONMUNILT PNiEL/2SOC91 OOOPB DATED JJLT J, \ 7+ J \ PLDEJ07-31 Scale: 1' 20' Sh.t 1 of 1 V t9BS. �zj A / ry 3. ASSUME LOCUS EXISTSENTIRELY WTIIN TKfl-1 RESIDENTIALCNE-FAMILY ZONINGDISTRICT. THE Land Owner: DeIulis Brothers Construction Co., Inc. M OIMENRCN L REWIREMENR PER TABU£ I ARE SHORN W THIS PLAN. S3 - t••t c/o Patrick DeIulis, 31 Collins Street Terrace, a PROPERTY ONE AND TONOGRAPHY PER AORTAL CN-THE-QiWND SUR4ET BY NORTH SHORE SURVEY vI / Lynn, MAL 01902-2205 CORPORATION,NOVEMBER,2007. DATUM: NGM OF 1929 C{ N 4. SEED REFERENCE FOR LDCN3: LAND MUT PLAN \ v PATROWICZ /essc(Cors R+B, v, Ba x AND Ba} r LANDra. Street, PItNT ENGINEERING 14 Grown Street, Salem. MA 01970 (978) 836-6400 c r N NORTH SHORE SURVEY CORPORATION d E \ 4 BroAr, Street,744-µ800 A 01970 (978) U O O THIS PLAN HAS BEEN REDUCED FROM THE ORIGINAL THE SCALE 0F THIS PLAN IS: / OtL�o O 2C) Q LOT 1 ^ o AREA m 19.448* S.F. 'Z S 87'36'03" W 24.74' J O 1 /,y010^� Zysp3p' Y, s ra LOT 2 PROPOSED PLOT PLAN LOT 1 CIRCLE HILL ROAD, SALEM 1" = 40' APRIL 28, 2017 NORTH SHORE SURVEY CORP. N i F 0 �o i / LOT 1 �^ o / / o AREA 19,4481 S.F. - ✓/ ��� S 87'36'03" W 24.74' LOT 2 PROPOSED PLOT PLAN LOT 1 CIRCLE HILL ROAD, SALEM 1" = 40' APRIL 28, 2017 NORTH SHORE SURVEY CORP. N i O / LOT 1 ° AREA 19,4481 S.F. - ✓ ��� S 87'3603" W 24.74' / O � LOT 2 PROPOSED PLOT PLAN LOT 1 CIRCLE HILL ROAD, SALEM 1" = 40' APRIL 28, 2017 NORTH SHORE SURVEY CORP. m i LOT 1 o % AREA 19.44a* &F. S 87'36'03° W 24.74' LOT 2 PROPOSED PLOT PLAN LOT 1 CIRCLE HILL ROAD, SALEM 1" = 40' APRIL 28, 2017 NORTH SHORE SURVEY CORP. O CSrZccE HLu �2� �uperTab. Tsb Fd 90%LargerLabelArea /// I S M E A D KEEPING YOU ORGANIZED No. 10301 PlaWFEM xa ,� IVA Pose MADEaMA GET ORGANI7F!)AT SMEAD.COM AIR LEAKAGE REPORT Date: October 17,2017 Rating No.: EH0820 Building Name: SALE CircleHiURd 40 Rating Org.: The Energy Hound Owner's Name: Phone No.: 978-233-1433 Property. 40 Circle Hill Rd Rater's Name: Ian Rex Address: Salem,MA 01970 Rater's No.: 1454792 Builder's Name: Dom Pezzulo Weather Site: BeverlyAP,MA Rating Type: Confirmed File Name: SALE CircleHillRd 40 CONF.BLG Rating Date: 2017-10-15 Blower door test Whole House Infiltration Heating Coding NaturalACH: 0.17 0.13 ACH @ 50 Pascals: 2.69 2.69 CFM @ 25 Pascals: 781 781 CFM @ 50 Pascals: 1225 1225 Eff.LeakageArea: [sq.in] 67.3 67.3 Specific LeakageArea: 0.00014 0.00014 EW100sfshell: [sq.in] 0.94 0.94 Duct Leakage Leakage to Outside Units Warts Bsmt CFM @ 25 Pascals: 28 CFM25/CFMfan: 0.0227 CFM25/CFA: 0.0081 CFM per Std 152: WA CFM per Std 152/CFA: WA CFM @ 50 Pascals: 44 Eff.LeakageArea: [sq.in] 2.41 Thermal Efficiency: WA Total Duct Leakage Units CFM251CFA Total Duct Leakage: 0.0180 Ventilation Mechanical: Exhaust Only ASHRAE ASHRAE Sensible Recovery Eff.(%): 0.0 62.2.2010 62.2-2013 Total Recovery Eff.(%): 0.0 Rate(cfrn): 72 72 92 Hours/Day. 24.0 24 24 Fan Watts: 8.3 Cooling Ventilation: Natural Ventilation Regarding ASHRAE 62.2 Ventilation Compliance TheASHRAE 62.2 flow rates shown above are the CONTINUOUS mechanical fresh air ventilation which will meet the Wvhole-building'requirement under that version of the standard. Both values incorporate any appropriate'infi@ration credit'. Intermittent mechanical ventilation may be used tithe flow rate is adjusted accordingly.For example,the runtime can be reduced to 12 hours per day using a doubled flow rate,as long as the system provides ventilation at least once every 3 hours. For more detail,refer to the appropriate standard. REM/Rate-Residential Energy Analysis and Rating Software v15A.2 This information does not constitute any v minty of energy cost or savings. ©1985-2017 Noresm,Boulder,Colorado. BUILDING FILE REPORT File Name:SALE CircleHillRd 40 CONF.BLG Date:October 17,2017 Property/Builder. Organization Building Name: SALE CircleHillRd 40 Org.Name: The Energy Hound Owners Name: Address: 11 Broadway,Suite 3 PropertyAddress: 40 Circle Hill Rd City,St,Zip: Beverly,MA 01915 City,St,Zip: Salem,MA01970 Phone No: 978-233-1433 Phone No: Website: www TheEnergyHound.com Builders Name: Dom Pezzulo Rater's Name: Ian Rex Phone No: 978-317-7785 Rater's Email: Info@TheEnergyHound.com EmailAddress: pezzuloda@gmail.com Rater's ID 1454792 Model: Provider ID: Development: Sample Set ID: Permit Date/Number: Last Field Insp: 2017-10-15 Rating Type: Confirmed Reason: New Home Rating No.: EHO820 Registry ID: 125055267 Registry Date: 10/17/2017 Verifier's Name: Verifiers ID: Verifiers Name- Verifiers ID: Verifiers Name:: Verifiers ID: Verger's Name: Verifiers ID: General Building Information Area of Cond.Space(sq ft): 3440 Volume of Cond.Space: 27344 Year Buift: 2017 Housing Type: Single-fatuity detached Level Type(Apartments Only): None Floors on or Above-Grade- 2 Number of Bedrooms: 4 Foundation Type: Conditioned basement Enclosed Crawl Space Type: NIA Number of Stories Including Conditioned Basement: 3 Thermal Boundary Location: NIA REM/Rate-Residential Energy Analysis and Rating Software v15.4.2 @ 1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 2 Foundation Walllnfo: �_ �. _ - ®�_1._ 2 Name CBsmtFwall CBsmt Fwall gar Library Type R10i ISO^4+shelf R10i ISO"4+shelf Length(ft) 128.0 24.0 Total Height(ft) 9.0 9.0 Depth Below Grade(ft) 7.5 7.5 HeghlAbove Grade(ft) 1.5 1.5 Location Cond->ambienttgrnd Cond->garagelgrnd Uo Value(wall,airfilm,&soil) 0.081 0.081 Uo value(wall assembly only) 0.710 0.710 Foundation Wall:R701 ISO"++shelf Type: Solid concrete or stone Thickness(in): 10.0 Studs: None Interior Insulation: Continuous R-Value: 10.0 Frame Cavity R-Value: 0.0 Cavity Insulation Grade: 1 Ins top: 0.0 ft from top of wall Ins Bottom: 4.0 It from top of wall Exterior Insulation: R-Value: 0.0 Ins top: 0.0 It from lop of wall Ins bottom: 0.0 It below grade Note: 1.5'ISO Slab Floor Info: 1 Name Slab>Ambiant Library Type Uninsulated` Area(sq ft) 920 Depth Below Grade(ft) 7.5 Full Perimeter(ft) 128 Exposed Perimeter(ft) 128 On-Grade Perimeter(ft) 0 REMIRate-Residential Energy Analysis and Rating Software v15A.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 3 Slab Floor..Uninsulated' Slab Covering Hardwood Perimeter Insulation(R-Value): 0.0 Perimeter Insulation Depth(ft): 0.0 Under-Slab Insulation(R-Value): 0.0 Under-Slab Insulation Width(ft): 0.0 Slab Insulation Grade: 1 Radiant Slab: No Note: Floor info: 1 2- Name Floor>Garage Floor>Ambiant Library Type R30,FG110-16 R30,FG110-16 Area(sq ft) 576 107 Location Btwn cond&garage Btwn cond&ambient Uo Value 0.035 0.035 REM/Rate-Residential Energy Analysis and Rating Software v15A.2 ©1985-2017 Noresm,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 4 Floor.R30,FG1 7416 Information From Quick Fill Screen: Continous Insulation R-Value 0.0 Cavity Insulation R-Value 30.0 Cavity Insulation Thickness(in.) 9.3 Cavity Insulation Grade 1.0 Joist Size(w x h,in) 1.5 x 9.3 Joist Spacing(in oc) 16.0 Framing Factor- (default) 0.1300 Floor Covering HARDWOOD Note: Layers Paths Cavity Framing Grade Inside Air Film 0.920 0.920 0.920 Floor covering 0.680 0.680 0.680 Subfloor 0.820 0.820 0.820 Cavity ins 30.000 0.000 0.000 Continuous ins 0.000 0.000 0.000 Framing 0.000 11.625 0.000 0.000 0.000 0.000 Outside Air Film 0.455 0.455 0.455 Total R-Value 32.875 14.500 2.875 U-Value 0.030 0.069 0.348 Relative Area 0.870 0.130 0.000 UA 0.026 0.009 0.000 Total Component UA: 0.035 Total Component Area: 1.0 Component Uo:0.035 REM/Rate-Residential Energy Analysis and Rating Software vi 5A.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd40 Page 5 Rim and Band Joist: _ _ 1 Name Bands>Ambient Area(sq ft) 207.0 Continuous Ins 0.0 Framed Cavity Ins 21.0 Cavity Ins Thk(in) 5.5 Joist Spacing 16.0 Insulation Grade 1 Location Cond->ambient Uo Value 0.047 Above-Grade Name Cond>Ambient Cond>Garage Library Type R21,FG16-16 R21,FG16-16 Gross Area(sq ft) 2121.00 192.00 Exterior Color Medium Medium Location Cond->ambient Cond->garage Uo Value 0.058 0.058 REM/Rate-Residential Energy Analysis and Rating Software v15A.2 ©1985-2017 Noresoo,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 6 Above-Grade Wall:R21,FG1 6.16 Information From Quick Fill Screen: Standard Wood Frame Continuous Insulation(R-Value) 0.0 Frame Cavity Insulation(R-Value) 21.0 Frame Cavity Insulation Thickness(in) 5.5 Frame Cavity Insulation Grade 1 Stud Size(w x d,in) 1.5 x 5.5 Stud Spacing(in o.c.) 16.0 Framing Factor- (default) 0.2300 Gypsum Thickness(in) 0.5 Note: R-21 FGbatt Gt,x6 Layers Paths Cavity Framing Grade Inside Air Film 0.680 0.680 0.680 Gyp board 0.450 0.450 0.450 Air GapiFrm 0.000 0.000 0.000 Cavity ins/Frm 21.000 6.875 1.030 Continuous ins 0.000 0.000 0.000 _ Ext Finish 0.940 0.940 0.940 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 23.240 9.115 3.270 U-Value 0.043 0.110 0.306 Relative Area 0.770 0.230 0.000 UA 0.033 0.025 0.000 Total Component UA: 0.058 Total Component Area: 1.0 Component Uo:0.058 REM/Rate-Residential Energy Analysis and Rating Software v15A.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 7 Window Infon ation: 1 2 3 Name F-DR-aside F 213.02.0 F 3,442.74.0 Library Type DbVLoE/Argon-Wood 27-25 27-25 LI-Value 0.360 0.270 0.270 SHGC 0.450 0.250 0.250 Area(sq ft) 4.00 6.00 43.00 Orientation North North North Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None Wall Assignment AGWall 1 AGWall 1 AGWall 1 Windowlnformation: 4 '1-5--1 _ 6 Name F 923.35.2 F 11,1216.45.2 F 1319.33.7 Library Type 27-25 27-25 27-25 U-Value 0.270 0.270 0.270 SHGC 0.250 0.250 0.250 Area(sq ft) 34.00 13.00 34.00 Orientation North North North Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None WaDAssignment AGWall 1 AGWall 1 AGWall 1 REM/Rate-Residential Energy Analysis and Rating Software A5.4.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 8 Window Infomlation: 7 7 8 9 Name L 11,1216.45.2 B 512.33.5 B 612.03.5 Library Type 27-25 27-25 27-25 U-Value 0.270 0.270 0.270 SHGC 0.250 0.250 0.250 Area(sq ft) 33.00 8.00 7.00 Orientation East South South Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Writer Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Wnter Shading None None None Adjacent Summer Shading None None None WallAssignment AGWall 1 AGWall 1 AGWall 1 Window Information: 10 11 12 Name B I-slider 10.50 B 923.35.2 B 1014.03.5 Library Type 27-25 27-25 27-25 1.1-Value 0.270 0.270 0.270 SHGC 0.250 0.250 0.250 Area(sq ft) 40.00 34.00 14.00 Orientation South South South Overhang Depth 0.0 0.0 0.0 Overhang To Top 0.0 0.0 0.0 Overhang To Bottom 0.0 0.0 0.0 Interior Winter Shading 0.85 0.85 0.85 Interior Summer Shading 0.70 0.70 0.70 Adjacent Winter Shading None None None Adjacent Summer Shading None None None WallAssignment AGWall 1 AGWall 1 AGWall 1 REM/Rate-Residential Energy Analysis and Rating Software v1 5A.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE QrcleHiIIRd 40 Page 9 Window Infomiation: 13 14 Name R 7,832.04.0 R Bsmt-Sm 21.32. Library Type 27-25 27-25 U-Value 0.270 0.270 SHGC 0.250 0.250 Area(sq ft) 24.00 5.00 Orientation West West Overhang Depth 0.0 0.0 Overhang To Top 0.0 0.0 Overhang To Bottom 0.0 0.0 Interior Winter Shading 0.85 0.85 Interior Summer Shading 0.70 0.70 Adjacent Winter Shading None None Adjacent Summer Shading None None WallAssignment AGWaII 1 AGWaII 1 Window:DbIILoE/Argon-Wood U-Value: 0.360 Solar Heat Gain Coefficient: 0.450 Note: Window:27-25 U-Value: 0.270 Solar Heat Gain Coefficient: 0.250 Note: boor Infomretionc 1 2 Name Front Therma R-7 garage OpaqueArea(sq ft) 14.0 14.0 Library Type R7 composite R7 composite WallAssignment AGWaII 1 AGWall2 Uo Value 0.126 0.126 Door.R7 composite R-Value of OpaqueArea: 7.0 Storm Door: No Note: REM/Rate-Residential Energy Analysis and Rating Software v15A.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE Circlel-lillRd 40 Page 10 [Rooflnformation: .__..__...__ .__.__ _.-.. Z.-_._��..__ _. 3.. Name Flat(less Hatch) Hatch Slope 10"DCE,vent V Library Type R-45 BFG x1012"Aft R3 hatch R-35 DBFG x10 vent V Ceiling Area(sq ft) 1317.00 10.00 350.00 RoofArea(sq ft) 1646.25 13.00 350.00 Color Medium Medium Medium Radiant Barrier No No No Type(Attic) Attic Attic Vaulted Uo Value 0.025 0.237 0.033 Clay or Cement Tiles: No No No Sub Roof Ventilation: No No No REM/Rate-Residential Energy Analysis and Rating Software 05A.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 11 Ceiling:R-45 BFG x1017'Att Information From Quick Fill Screen: Continous Insulation(R-Value) 7.0 Cavity Insulation(R-Value) 38.0 Cavity Insulation Thickness(in) 10.0 Cavity Insulation Grade 1 Gypsum Thickness(in) 0.500 Insulated Framing S¢e(w x h,in) 1.5 x 9.3 Insulated Framing Spacing(in o.c.) 16.0 Framing Factor- (default) 0.1412 Ceiling Type Attic Note: 12"BFG in x10 Layers Paths Framing Cavity Grade Inside Air Film 0.610 0.610 0.610 Gyp board 0.450 0.450 0.450 Cavity Ins/Fnn 11.625 38.000 0.000 Continuous ins 7.000 7.000 7.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.610 0.610 0.610 Total R-Value 20.295 46.670 8.670 U-Value 0.049 0.021 0.115 Relative Area 0.141 0.859 0.000 UA 0.007 0.018 0.000 Total Component UA: 0.025 Total Component Area: 1.0 Component Uo:0.025 REM/Rate-Residential Energy Analysis and Rating Software v15.4.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd40 Page 12 Ceiling:R3 hatch Information From Quick Fill Screen: Continous Insulation(R-Value) 3.0 Cavity Insulation(R-Value) 0.0 Cavity Insulation Thickness(in) 0.7 Cavity Insulation Grade 1 Gypsum Thickness(in) 0.000 Insulated Framing S¢e(wx h,in) 0.0x 11.3 Insulated Framing Spacing(in o.c.) 24.0 Framing Factor- (defined) 0.0020 Ceiling Type Attic Note: Layers Paths Framing Cavity Grade Inside Air Film 0.610 0.610 0.610 Gyp board 0.000 0.000 0.000 Cavity Ins/Frm 0.825 0.000 0.000 Continuous ins 3.000 3.000 3.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Outside Air Film 0.610 0.610 0.610 Total R-Value 5.045 4.220 4.220 U-Value 0.198 0.237 0.237 Relative Area 0.002 0.998 0.000 UA 0.000 0.236 0.000 Total Component UA: 0.237 Total Component Area: 1.0 Component Uo:0.237 REMIRate-Residential Energy Analysis and Rating Software v15.4.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 13 Ceiling:R-35 DBFG x10 vent V Information From Quick Fill Screen: Continous Insulation(R-Value) 0.0 Cavity Insulation(R-Value) 34.9 Cavity Insulation Thickness(in) 9.3 Cavity Insulation Grade 1 Gypsum Thickness(in) 0.500 Insulated Framing S¢e(w x h,in) 1.5 x 9.3 Insulated Framing Spacing(in o.c.) 16.0 Framing Factor- (default) 0.1412 Ceiling Type Vaulted Note: x10 10"DBFG @R-4.1 vent V - Layers Paths Framing Cavity Grade Inside Air Film 0.610 0.610 0.610 Gyp board 0.450 0.450 0.450 Cavity Ins/Frm 11.625 34.900 0.000 Continuous ins 0.000 0.000 0.000 Plywood 0.930 0.930 0.930 Shingles 0.400 0.400 0.400 0.000 0.000 0.000 Outside Air Film 0.170 0.170 0.170 Total R-Value 14.185 37.460 2.560 LI-Value 0.070 0.027 0.391 Relative Area 0.141 0.859 0.000 UA 0.010 0.023 0.000 Total Component UA: 0.033 Total Component Area: 1.0 Component Uo:0.033 Mechanical Equipment:General Number of Mechanical Systems: 2 Heating SetPoint(F): 68.00 Heating Setback Thermostat: Present Cooling SetPoint(F): 78.00 Cooling Setup Thermostat: Present REM/Rate-Residential Energy Analysis and Rating Software v15A.2 ©1985-2017 Norasco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 14 Heat:GaF AUHiBO60A9N31C SystemType: Fuel-fired air distribution Fuel Type: Natural gas Rated Output Capacity(kBtuh): 57.0 Seasonal Equipment Efficiency. 95.0 AFUE Auxiliary Electric: 635 Eae Note: American AUMB060A9H31C` 60/57 95 351e #10273053 Location: Conditioned area Performance Adjustment: 100 Percent Load Served: 100 Number Of Units: 1 Water Hiking Equipment:Gains NavNPE-2105 99 Water Heater Type: Instant water heater Fuel Type: Natural gas Energy Factor: 0.99 Recovery Efficiency: 0.00 Water Tank Size(gallons): 0 Extra Tank Insulation(R-Value): 0.0 Note: NavNPE-210S .99 #6478772 Location: Conditioned area Percent Load Served: 100 Performance Adjustment: 100 Number Of Units: 1 DHW Efficiencies All bath faucets&showers<=2gpm: false All DHW pipes fully insulated>=R-3: false Recirculation type: None(standard system) Farthest fixture to DHW heater 30 TOTAL Pipelongth for longest DHW run: 60 DWHR unit present?: false REMIRate-Residential Energy Analysis and Rating Software v15.4.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHiIIRd 40 Page 15 Duct System Infomration: Name Warm Bsmt Heating System GaFAUH1B060A9H31C Cooling System NIA SuppyArea(sq R) 696.6 Return Area(sq ft) 645.0 Conditioned FloorArea(sq ft) 3440.0 #of Registers 5 Duct Leakage Qualitative Assessment-Not Applicable Duct Leakage to Outside: 28.00 CFM @ 25 Pascals Supply Duct Leakage-NotApplicable Return Duct Leakage-NolApplicable Total Duct Leakage: 62.00 CFM @ 25 Pascals Duct Tightness Test: Postconstruction Test Duct Infomtat on: 1 2 3 771 Type m supply Return supply PercentArea 50.0 50.0 50.0 R-Value 6.0 6.0 6.0 Location Conditioned basement Conditioned basement Conditioned space Duct IrrformaGon: 4 Type Return PercentArea 50.0 R-Value 6.0 Location Conditioned space REM/Rate-Residential Energy Analysis and Rating Software v16.4.2 ©1985-2017 Noresoo,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd40 Page 16 Infiltration and Mechanical Ventilation Whole House Infiltration Measurement Type: Blower door test Heating Season Infiltration Value: 1225 CFM @ 50 Pascals Cooling Season Infiltration Value: 1225 CFM @ 50 Pascals Shelter Class 4 Code Verification: Tested Mechanical Ventilation for IAQ Type: Exhaust Only Rate(cfm): 72 Sensible Recovery Efficiency(%): 0.00 Total Recovery Efficiency(%): 0.00 Hours per Day. 24.00 Fan Power(watts): 8.30 ECM Fan Motor: false Ventilation Strategy for Cooling Cooling Season Ventilation: Natural Ventilation Lights and Appliances SimplfiedAudit Refrigerator KWh: 563 Refrigerator Location: Conditioned Dishwasher EF: 0.00 Dishwasher kWh/yr: 260 Dishwasher Capacity: 12 Dishwasher kWh/Year, 260 Range/Oven Fuel Type: Natural gas Induction Range: No Convection Oven: No Clothes Dryer Fuel Type: Electric Gothes Dryer Location: Conditioned Clothes Dryer Moisture Sensing: No Clothes Dryer CEF: 2.62 Gothes Washer Location: Conditioned Clothes Washer LER: 151.0 Clothes Washer IMEF: 2.155 Gothes Washer Capacity: 3.310 Clothes Washer Electricity Rate: 0.11 Clothes Washer Gas Rate: 1.22 REM/Rate-Residential Energy Analysis and Rating Software v15A.2 @ 1985-2017 Noresoo,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd 40 Page 17 Lights and Appliances Clothes WasherAnnual Gas Cost: 12.00 Percent CFLs: 100.0 Percent Fluorescent: 0.0 Percent Exterior Lights: 100.0 Percent Garage Lights: 100.0 Ceiling Fan CFM/Watt: 0.00 Mandatory Requirements IECC Requirements Verified IECC 04: false Verified IECC O6: false Verified IECC 09: false Verified IECC 12: false Verified IECC 15: true Verified NY-ECCC 2016: false Verified Michigan: false Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist(National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist(optional) ENERGY STAR Version 3 Appliances Refrigerators: 0 Ceiling Fans: 0 Exhaust Fans: 0 Dishwashers: 0 ENERGY STAR Version 3 Basements Basement Wall Area 50%Below Grade: false Basement Floor Area: 0 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist: false EPA Field App ID Notes REM/Rate-Residential Energy Analysis and Rating Software W 5.4.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDING FILE REPORT SALE CircleHillRd40 Page 18 WARNING CONFIRMED for.. Ceiling area-slopes NOTES for BLDR VERIFY Orientation CONF'd?? CeilingHeights CONF'd?? Bath Fan set to: CORRECTIONS NEEDED REFR (691) DISH RANGE: NG Elec Prop +Convection WASH MEF LER_ kWh/y Cap_ EI-Rate— Gas Rate_ An Gas Cost_ DRYR Gas +MoistSens T-stat x2 C-Fan (70.4)? HRV Sens% Tot% watts Fur-1 Fur-2 AC-1 coil /condenser AC-2 coil /condensor WTR REG# #ELEC #GAS REM/Rate-Residential Energy Analysis and Rating Software v15A.2 ©1985-2017 Noresco,Boulder,Colorado. BUILDER'SAFFIDAVIT Property/Builder: Owner's Name: Property Address: 40 Circle Hill Rd City,St,zip: Salem,MA 01970 Phone No.: Builder's Name: Dom Pezzulo Model: Development Phone No.: 978-317-7785 Rating Date: 2017-10-15 Rating No.: EH0820 IMPORTANT NOTICE TO BUILDER Builder affirms in this affidavitthat all components listed in the Building File Report are accurate and incorporated into this New Home. Builder agrees to permit home energy rating system(HERS)Provider and/or Rater,to randomly verify components solely for the benefit of the HERS Provider's and/or Rater's interest. The HERS Provider and Rater do not create or imply any duty or obligations to Builder or any subsequent owner. Builder is responsible for making any inspections to protect Builder's interest There is no GUARANTEE or WARRANTY,expressed or implied,from the HERS Provider or Rater as to this New Home. Builder's Signature: Date: / / HERS Index: 50 Ian Rex-Energy Rating Reason: Confirmed t•"tw 'Y, IY�Hound 11 '�e ,Broadway,Suite 3, Raters Sgriature Fnm` I Beverly,MA 01915 Date: / / HQ�/. '( 17.10.1721:1 3:15 -04-00- REM/Rate-Residential Energy Analysis and Rating Software v15A.2 This information does not constitute any warranty of energy cost or savings. ©1985-2017 Noresco,Boulder,Colorado. Registry Number. 1210820 7 (/7,',� • Rating Number. EI-Ian Rex low ,�Ap� Certified Energy Rater: Ian Rex �7r/'ry a,{/Y�� Rating Date: 2017-1415 40 Circle Hill Rd Rating Ordered For: Salem,MA01970 f� Estimated Annual Energy Cost Confirmed 5 Stars Plus Use MMBtu cost Percent Confirmed Heating 64.2 $1264 43% Cooling 0 $0 0% Uniform Energy Rating System Energy Efficient Hot Water 11.3 $214 7% 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 4 Stars Plus 5 Stars 5 Stars Plus Lights/Appliances 26.1 $1264 43% 500-401 400-301 300-251 250-201 200-151 150-101 11 100-91 1 0-86 1 85-71 1 70 or Less Photovoltaics -0.0 $_0 -0% HERS Index: 50 Service Charges $190 6% Generallnfomtation Total 102.9 $2931 1000h Conditioned Area: 3440 sq.ft. HouseType: Single-family detached Conditioned Volume: 27344 cubic ft. Foundation: Conditioned basement Bedrooms: 4 This horns meets or exceeds the minimum criteria for all of the following: Mechanical Systems Features Heating: Fuel-fired air distribution,Natural gas,95.OAFUE. Water Heating: Instant water heater,Natural gas,0.99 EF,0.0 Gal. I ECC 2015 MA Amendments Duct Leakage to Outside: 28.00 CFM25. Ventilation System: Exhaust Only:72 cfm,8.3 watts. Programmable Thermostat: Heating:Yes Cooling:Yes Building Shell Features Ceiling Flat: R-45.0 Slab: R-0.0 Edge,R-0.0 Under Sealed Attic: NA Exposed Floor: R-30.0 Vaulted Ceiling: R-34.9 Window Type: U-Value:0.270,SHGC:0.250 Above Grade Walls: R-21.0 Infiltration Rate: Htg: 1225 Cig: 1225 CFM50 Foundation Walls: R-10.0 Method: Blower door test Lights and Appliance Features TITLE Percent Interior Lighting: 100.00 Range/Oven Fuel: Natural gas Com an Ian Rex-Energy P y Hound 11 Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Address '�e Broadway,Suite 3, Refrigerator(kWhiyr): 563.00 Clothes Dryer CEF: 2.62 City,State,Zip �`. �'1'B�everly,MA 01915 Dishwasher(kWh/yr): 260.00 Ceiling Fan(cfm=aft): 0.00 oun 978333-],433 101 The Home Energy Baling Standard Disdosure for this home is available from the rating provider. 1 21:12:50-04'00' REM/Rate-Residential Energy Analysis and Rating Software 05.4.2 This information does not constitute any warranty of energy cost or savings. ©1985-2017 Nomsco,Boulder,Colorado. RESNET HERS Index Certificate HERS®Index 40 Orde Hill Rd /.� Salem,MA 01970 More Energy Rater Ian Rex 150 Registry Or 125055267 Annual Estimates': 140 Elec(kM): 7711 Gas(Therms): 710 Existing 130 002 emissions(Tons):9 Homes 120 Energy Savings($p':3541 'Based on standard operating conditions 110 "Based on U S.DOE designation of a HERS Standard 100 Index of 130 as the'Typical Existing I-lome' New Home eo 70 TITLE ('idea ene,er This Home Company it He a n 50 Address �1b0 era d r.smee 3, s �0ev r! MA01915 40 Gly State.Zip -2017,16,1721 97e-233-1433 eon v fa. 21 1241 .� 30 H 11� �.�. 20 10 This home has been inspected Zero Energy U and performance tested in �C�[ILT® Home accordance with Chapter of rtGJJ/yG 1 �^ Less Energy the RESNETstandards. w .resnet.us RESNET HOME ENERGY RATING Standard Disclosure For home located at: 40 Circle Hill Rd City: Salem State: MA 1. ❑x The Rater or the Rater's employer is receiving a fee for providing the rating on this home. 2. E] In addition to the rating,the Rater or Rater's employer has also provided the following consulting services for this home: ElA. Mechanical system design ❑ B. Moisture control or indoor air quality consulting ElC. Performance testing and/or commissioning other than required for the rating itself ❑ D. Training for sales or construction personnel ❑ E. Other(specify bebw) 3. ❑ The Rater or Rater's employer is: A. The seller of this home or their agent B. The mortgagor for some portion of the financed payments on this home C. An employee,contractor or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Rater's employer is a supplier or installer of products,which may include: Installed in this home by: OR Is in the business of: HVACsystems ❑ Rater ❑ Employer ❑ Rater ❑ Employer Thermal insulation systems Rater Employer ❑ Rater ❑ Employer Air sealing of envelope or duct systems Rater Employer ❑ Rater ❑X Employer Windows or window shading systems Rater ❑ Employer ❑ Rater ❑ Employer Energy efficient appliances Rater ❑ Employer Rater ❑ Employer Construction(builder,developer,construction Rater Employer Rater Employer contractor,etc.) Other(specify below): Rater Employer Rater Employer S. ❑X The Rater or the Rater's employer is receiving a fee for providing the rating on this home. I attest that the above information is true and correct to the best of my knowledge. As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network(RESNET). The national rating quality control provisions of the rating standard are contained in Chapter One 4.C.8.of the standard and are posted at http://resnet.us/standards/RESNET_Mortgage_Industry_National_HERS_E The Home Energy Rating Standard Disclosure for this home is available from the rating provider. Ian Rex 1454792 Rater's Printed Name (&',Br-'Ld—y,Su�te3, Ian Rex-Energy Certification# 1� Beverly,MA01915 October 17,2017 Raters Sgnature II2017.10.1721:12:23 Date RESNET Form 0300-2 6,7 -04'00'