Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
15 VICTORY RD - BUILDING INSPECTION
r Cr-- zs(, � The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF Massachusetts State Building Code,780 CMR SALEM Revised Mnr 2011 Building Permit Application To Construct, Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date A i d: �nw✓ 1L�%J /t7 I Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Pr�!pty f`dress: _U 1.2 Assessors Map&Parcel Numbers 1.1a Is this an accepted street?y X no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage(A) 1.5 Building Setbacks(ft) Front Yard Side Yards (tear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: L8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Check ifyes❑ Municipal❑ On site disposal system [3 SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'ofRecord: Nancy Martin SA�eM Name(Print 5 Victoryroad City,State,ZIP 978-741 -3554 Martin. corr No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK (check all that apply) New Construction Existing Building❑ Owner-Occupied ❑ 1 Repairs(,) ❑ Alteration(,) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work2: a}oV +4-IC. Solar SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1.Building. $ 00 .Co I. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ - Suppression) Total All Fees:$ Check No._Check Amount: Cash Amount:_ 6.Total Project Cost: $ .UJ 0 Paid in Full 11 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) 1_ 6U-5251-4 28 'ame< License Number Expiration a� P} ( LX Name S I r of11CSL Holder ..{-�,. �i t^U✓y (pt- List CSL Type(see below) U No.and Street pp pp Type Description SC1 WS I t A A Q19 C o Un U restricted(Buildin s u to 35,000 cu.If.) _l R Restricted 1&2 FamilyDwelling CitylTown,S ""/..IP M Mason ry RC Roofin Covenn WS Window and Sidin SF Solid FucfBunting Appliana [1LJ PV OZO(L1YQ VIVIV�'Stp�(}I I Insulation Tele hone Email address rv3 D Demolition 5.2 Registered Home Improvement Contractor(HIC) \lluly� t polar (rev IaD2Y I.L.C. t lo�4s i HIC Com any Name or HIC R gistrant Name 1-- HIC Registration Number E pirat on ale 4�3P�1 '30D V�. h�CLSoIG[r�vivtvL�Solttr No.and Yo Street 4(ODL} Ur Entail a ail address C. r"t o $ "1$13053o1p5 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ......... No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize VI V IrCl Sfl'W to act on my behalf, in all matters relative to work authorized by this building permit application. 10/8/14 Print Owner's Name(E.lec nic Signature) Date SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below, 1 hereby attest under the pains and penalties of perjury that all of the information contained in th' p Lion is true and accurate to the best of my knowledge and understanding. Prim Chv s )r riztd Agent's Name(Electronic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program), will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/do 2. When substantial work is planned,provide the information below:. Total Floor area(sq.R.) (including garage, finished basement/attics,decks or porch) Gross living area(sq,ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" A4 1I2013 CERTIFICATE OF LIABILITY INSURANCE °A�`12W°°"YYY' it/0 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICATE DOES NOT AFFIRMATIVELY ORNEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES -BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(les) must be endorsed. If SUBROGATION IS WAIVED,subject to the terns and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the - certificate holder in lieu of such endorsement(s). . PRODUCER CONTA MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHONE FAX A/C Not DENVER,CO 80202-5534 EED IL -L - Attn:Denver.certrequest@malsh.rum,Fax:212.948.4381 INSURE S AFFORDING COVERAGE MAIC w 462738-STND-GAWUE-13.14 INSURER A:Evanston Insurance Company 35378 INSURED National Union Fire Insurance Co of PA Vivid!Solar,Inc. INSURER B 4931 N 300 W INSURER C:New Hampshire Insurance Company 23841 Provo.UT W04 INSURER o: INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SFA-002368030-06 REVISION NUMBER:O THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOL SUBR POLICY EFF POLICY EXP POUCYNUNBER MMn) MMI° LIMITS A GENERAL LIABILITY 13PKGWE00274 11/0112013 11101/2014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL UABIUTY R NT 50,000 PREMISES Eaa rmnoe $ CLAIM&MADE 111 OCCUR MED EXP(Any one person) $ 5,000 PERSONAL a AOV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,g00 GEN'L AGGREGATE LIMIT APPLIES PER: - PRODUCTS-COMP/OP AGO $ 2,000,000 X POLICY JFCT PRO- LOC $ B AUTOMOBILE LIABILITY 9701087 11/0112013 11/01/2014 COMBINED SINGLELIMIT 1,000,000 Ea accident E S X ANY AUTO 9701088 - 11/01/2013 11101/2014 BODILY INJURY(Perperson) E ALL OWNED SCHEDULED BODILY INJURY Per accident) $ AUTOS AUTOS ( i X N NON-OWNED PROPERTY DAMAGE HIRED AUTOSAUTOS Peracdderl $ E A UMBRELLA Line X OCCUR 13EFXWE00088 11/01/2013 11101/2014 EACH OCCURRENCE $ 10,000,000 X EXCESS LAB CLAIMS-MADE AGGREGATE S 10,000,000 DED I I RETENTIONS g C WORKERS COMPENSATION 029342334; 029342335 11101/2013 1110112014 X I ICSTATU- OTH- AND EMPLOYERS'LIABILITY C ANY PROPRIETOWPARTNER/EXECUnVE YIN p29342336; 029342337 711012013 11101/2014 1,000,000 G OFFICERIMEMBER EXCLUDED? 7 MIA 029342338 11/0112013 IVOI12014 E.L.EACH ACCIDENT EA $ 1,0D0,000 (Mandatary In NH) E.L.DISEASE-EA EMPLOYE E I yes,desrnbe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Errors&Omissions& 13PKGW00029 11/01/2013 11101/2014 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS I V MCLES(Artaeh ACOND tat,A Moral Remarks Schedule,X mare span h m4eimdl e Certiticale Holder and others as defined in the written agreement are incWded as additional insured where required by written wwrad with respect to General Uablity.This insurance is primary and non- nbibubry over any e)dsdng insurance and limited to liability arising out of the operations of the named insured and where required by written comma Waiver of subrogation is applicable where required by written ntract with respect to General Uabibty and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Pafsloe .r .S,lldylc7n. JQIa/sG ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of IndustrialAccidents Office of Investigations I Congress Street, Suite 100 Boston,MA 02114-2017 'f www.mass.gov/dia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Vivint Solar Developer LLC Address: _4931 North 300 West_ CitV/Srate/``Zi Provo _UT 84604 Phone 4: 801-704-9389 Are you an employer?Check the appropriate box: Type of project(required): I.[K I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time)."' have hired the sub-contractors 6. ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. I 7. ❑ Remodeling shipand have no employees Phase sub-contractors have 8. ❑ Demolition working for me in any capacity. employees and have workers' (No workers' comp. insurance comp. insurance. 9. ❑ Building addition required.] 5. ❑ We are a corporation and its 10.0 Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I LEI Plumbing repairs or additions myself. (No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.❑ Other, — comp. insurance required.] •Any applicant that checks box 41 must also till out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such. :Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they most provide their workers'comp.policy number I am an employer that is providing workers'compensation insurancefor my employees. Below is the policy and job site information. k Insurance Company Name:._ New Hampshire Insurance CompanyPolicy#or Self-ins. Lic. #: 029342228_ _ Expiration Date: 11/01/14 Job Site Address:_A�l �). City/State/Zip:_ Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify�under pains r ut penaltie'ujperjurp r r the information provided1 rab��ovef is true andcorrect -- -- — Date: Phoncoit 01-704-9389 Official use only. Do not write in this area,to be completed by city or town official. City or Town: — _Permit/License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other_ Contact Person: ___ _ _ Phone#: 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLO. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, UT 84604 Update Address and return card.Mark reason for change. SCA 1 0 2OM-05/11 Address Renewal Employment Lost Card lit Massachusetts --Department of Public Safety Board of Building Regulations and Standards Construction Supen'isor - License: CS-0452¢4 JAMES R SHERMAN -- 6 Fox Hollow Drive s x SAUGUS MA O1"6 s Expiration Commissioner 08/28/2016 a vivio t, so a i� 4931 North 300 West Structural Group Provo,UT84604 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scott.wysslingCa vivintsolar.com September 18,2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Martin Residence 15 Victory Road, Salem MA S- 3987741 8.00 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of assumed 2 x 6 dimensional lumber at 16"on center. The attic space is partially finished and photos indicate that there was limited access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 12 and 43 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure 'B", Zone 2 per (ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. viv!nt. s. U - a r Page 2 of 2 B. Loading Criteria 10 PSF= Dead Load roofing/framing 40 PSF=Live Load(ground snow load) 5 PSF= Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual',which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2' with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four(4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. ery truly yours, �tN OF c Scott E.V ling, ciw MA License No. ; so 9pF, FGISTEPE FSSIONAL blblD9�. '. a� U C o 1 I En EI- -I- Ny�z I C' n o JUNCTION BOX ATTACHED TO 1 ARRAY USING ECO HARDWARE TO KEEP JUNCTION BOX OFF ROOF I FIEWIA j I I I I PV SYSTEM SIZE: T 8.00 kW DC I I li 30'OF PVC CONDUIT I w FROM JUNCTION BOX TO ELEC PANEL I PV INTERCONNECTION POINT, I LOCKABLE DISCONNECT SWITCH, I ANSI METER LOCATION, I •� 2 &UTILITY METER LOCATION I I - - - - - - - - I m (32)TUna Solar TSM-250 PA05.18 MODULES WITH A Enphase M215-60-2LL-S2x-ZC MICRO-INVERTER = M < MOUNTED ON THE BACK OF EACH MODULE I h I I I I z z SHEET NAME: I I W Z I I I zJ5g - ----L------ --------J SHEET ' NUMBER: 15 Victory Rd, Salem MA 01970 IPV SYSTEM SITE PLAN C) SCALE: 3/32"= T-0" > d m _ m� �m On qm a up Cy m ma C C 3 m 2 4] 0 m O z � N 1) 2 m m \10\0 O O N�N ID o_O acID J w52 N D r CD m w U) m m I m o X O OA O C� T N~ T � 1 V r D Z C= Di INSTALLER VIVINTSO AR . J� Martin Residence P\/ 2 0 m y ROOF m y INSTALLER NUMBER:1.877.404.4129 �/O�/�1Y11� 1 ry V m m MA UGENSE:MAHIC 170868 15 Victo Rd p PLAN DRAWN BY:Laura AR 3234351 ast Mo lifatl:9111/2014 UTILITY ACCOUNT NUMBER:1309191009 CLAMP MOUNTING SEALING U PV3.0 DETAIL WASHER C o m LOWER -0 o^p SUPPORT '(n z�f m a ® s°�z �>E Zm PV MODULES, TYP. MOUNT "'".„.L,, '.' "..:-.. m'o OF COMP SHINGLE ROOF, FLASHING PARALLEL TO ROOF PLANE / 2 1/2" MIN 5116"0 x 4 1/2" PV ARRAY TYP. ELEVATION S EIMUM EL LAG SCREWS NOT TO SCALE TORQUE= 13±2 ft-Ibs r CLAMP ATTACHMENT NOT TO SCALE •e .CLAMP+ ATTACHMENT �p CANTELEVER U4 OR LESS COUPLING L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. e pmA PERMITTED COUPLING 5 m o m CLAMP+ CLAMP CLAMP w a ATTACHMENT SPACING COUPLING PHOTOVOLTAIC MODULE > j > z w m m i � w z m w z a F 3 N z a � SHEET NAME Z : L=PORTRAIT F- W CLAMP SPACING Z Q O W ECO 2 0 L= COMPATIBLE PV SYSTEM MOUNTING DETAIL NUMBE LANDSCAPE MODULE R: CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 cc+i NOT TO SCALE a Inverter Ratings(Guide Section 4) m.ener Makammdel Enpbeaa M215-or LL-sex-zc Conduit and Conductor Schedule MODULE DETAIL Max DCvel Begna 4s Va. Tag Description Wire Gauge 4ofcondueore Conduit Type Conduit sae Maa Power�40°C 215 Wet6 I Enthuse engage Penn-THAN-4 t2AWG • CON NIA-Free Nr /1� ce Nominal AC Voltage 240 Vets W p Trine Solar TSM-250 PA05.16 Max A.Cunenl 0.9 Amps I Sore Copper Gmund IEGCIGE01 6AWG 1 Wb Fina Air NIA-Free Nr U SOLAR MODULE Mex 01 Raring 20 Ampe 2 THWM-2 10AWG a %'C 0'-t' Max Numoar of PenelP/Clrtvil 1] $ THWN-2-Gmund 6AWG I PJC e'-1' 3 Tri 8Neu 3 PVC 0'1' NOTES FOR INVERTER CIRCUITS(Guide Section 8 anal 9), m w 3 THWN-2-Gmund BAWG I PVC 0'-1' 7�'m 1.)IF UTILITY REQUIRES A VISIBLE BREAK SWITCH,DOES THIS PV Module Ratings @ STC(Guide Section 5) �o Q D Enphass M215-60�2LL-S2x-ZC SWITCH MEET THE REQUIREMENTS? U z Modq Make04adel Trina Spar TSM-250 PAMAS MICRO-INVERTERMODULE ATTACHED YES NO XNA Max Pourer-Point Current(imp) 8.27 Amps n ZD EACH MODULE,ATTACHED 2.)IF GENERATION METER REQUIRED,DOES THIS METER Mex Power-Point Voltage Vap) 30.3 Vulte �`so WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS? O Open Vptage(Voc) W.6 Vgts y O YES NO XNA Short-Circuit Cunent gsc) 8.85 Ames L Q 3.)SIZE PHOTOVOLTAIC POWER SOURCE DC)CONDUCTORS Max Series Fuse(OCPD) 15 Amps (6 BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum P.,at STC(Pori 250 Wags S � MICROINVERTER CONNECTION RATING AT DISCONNECT. Maximum System Voltage IDW(IEC4600(UL) L TO ENGAGE TRUNK CABLE 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Vac Temperature CDeRpient -O.J2 %PC TO INVERTER OCPD AMPERE"TING(Sea Guide Section 9). S.)TOTALOF 2 INVERTER OCPDhG.ONE FOR EACH NOTES FOR ARRAY CIRCUIT WRING(Guide Section 6 and 8 and Appendix 01, PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY WITH 120%BUSBAR EXCEPTION IN 1.)Lawast expected ambient temperature based on ASHRAE minimum mean extreme NEC 890.64(8)(2)(a)? XYES NO dry bulb temperature for ASHRAE IocaOon most similar to installation location: -19°C . M6 BARE CU GROUND (GROUNDING ARRAY) Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb temperature for ASHRAE location most similar to installation location: 39°C Sign for inverter OCPD and AC Disconnect: 3J 2005 ASHRAE fundamentals 2%design temperatures do not exceed 47°C in the United States(Palm Springs,CA is 44A°C).For less than 9 cument-carrying conductors Solar PV System AC Point of Connection in roof-mounted sunlit conduit at least os above roof and using the outdoor design x AC Output Current 28.800000 1 Amps temperature of 47"C or less(ell of United States). _ • e Nominal AC Voltage 24UI Vale a.)12 AWG,90°C conluUom am generally acceptable for modules with lsc of 7.68 Amps or less when protectecl by a 12-Amp or smaller fuse. Ce THIS PANEL(UTILITY BAND LTIPLESOLAR SOURCES b.)10 AWG,90°C conductors are generally acceptable for modules with Isc of 9.6 Amps (UTILITY AND SOLAR) or less when passadedb a 1 5-Amp or smaller fuse. as 16 NOTE: NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY no ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR an pe PV CIRCUIT 1: 16 MODULES/PARALLEL ENVOY Box $ s S A, 16 • • • O (D ///��� N G, p Q 1 IMPZ m Q } I{ g @ '_.n • -_,� __�, E 1.0 MURRAY POINT OF DELIVERY > p N COMBINER AND INTERCONNECTION H w w m \�O iO PANEL 125A/240V SIEMENS ¢ ¢ J 3 ---- --- \G, G LWO04NR 60N240V m y < qa 'A\ 7' UNFUSED NEMA3 Z Z o I (J \t�s OR EQUIVALENT LNF222R OR M SHEET PV CIRCUIT 2: 16 MODULES/PARALLEL aaT\ 6L SREC/ANSI EQUIVALENT NAME: METER I \O7 EXISTING is • 2O tQ j \P InD LOAD- EN Z 1 i oA LOAD-CENTER J U I MA-1 S • • • s/x f E to I \\ 4pA SHEET 'r NUMBER: ___ _ ____ ______A__ _____ ____ ____ _ ___ _____ _____ \\ MILBANK VISIBLE/LOCKABLE p JUNCTION BOX 2 \\ 3 100A OR 3 'KNIFE'A/C '3 � NEC 2.�14 Compliant ' WITH IRREVERSIBLE E 1.0 \\ EQUIVALENT DISCONNECT GROUND SPLICE E 1.0 U5934-XL-BLG E 1.0 E 1.0 LJ.I Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: NANCY MARTIN Project Address: 15 VICTORY RD,SALEM MA A.System Description: The array consists of a 8 kW DC roof mounted Photovoltaic power system operating in parallel with the utility grid.There are(32)250- watt modules and(32)215-watt micro-inverters,mounted on the back of each PV module.The array includes(2) PV circuit(s).The array is mounted to the roof using the engineered racking solution from Eeolibrium Solar. B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Comp. Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B.Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Eeolibrium Solar b.Product Name: Ecorail c.Total Weight of PV Modules and mounting hardware: 1376 Ibs d.Total number of attachment points: 75 e.Weight per attachment point: 18.34 Ibs f.Maximum spacing between attachment points: 'See attached engineering talcs g.Total surface area of PV array: 563.52 square feet h.Array pounds per square foot: 2.44 lbs/square foot i.Distributed weight of PV array on roof sections: -Roof section l: (20)modules,(48)attachments 17.91 pounds -Roof section 2: (12)modules,(27)attachments 19.11 pounds per square foot vivint. 5()i:�I r 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 250-PA05.18 32 modules Module Specs Pmax-nominal maximum power at STC - 250 watts Vmp-rated voltage at maximum power - 30.3 volts Voc-rated open-circuit voltage - 37.6 volts Imp-rated current at maximum power - 8.27 amps Ise-rate short circuit current - 8.85 amps 8. Inverter (UL 1741 listed) Qty Enphase M215-60-21:.hS22 32 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits - 2 PV circuit 1 - 16 modules/inverters (20)amp breaker PV circuit 2 - 16 modules/inverters (20)amp breaker 2011 NEC Article 705.60(B) vivint. r D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 14.4 amps Continuous current adjustment factor 125% 2011 NEC Mdcle 705.60(B) PV circuit continuous current rating 18 amps 2.Overcurent protection device rating PV circuit continuous current rating 18 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4 cC (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Arude 705.60(B) Adjusted PV circuit continuous current 25.3 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 800X� 2011 NEC Aredc 705.60(B) Final Adjusted PV circuit continuous current 31.6 amps Total derated ampacity for PV circuit 31.6 amps Conductors(tag2 on l4ine)must be rated for a minimum of 31.6 amps THWN-2(90°C) #lOAWG conductor is rated for 40 amps (Use#10AWG or larger) 2011 NEC Arudc 705.60(B) 4.Voltage drop(keep below 3%total) 2 parts: 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors(from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.41% The largest number of micro-inverters in a row in the entire array is 12 inCircuit 2.According to manufacturers specifications this equals a voltage drop of 0.41 %. 2.AC conductor voltage drop: = 1 x R x D (+240 x 100 to convert to percent) = (Nominal current of largest circuit)x (Resistance of#10AWG copper)x(Total wire run) =(Circuit 1 nominal current is 14.4 amps)x(0.00126Q)x(60� +(240 volts)x(100) 0.45% Total system voltage drop: 0.86% vivint. ) r,, Wp EcolibriumSolar Customer Info Name: 3234350 Email Phone: Project Info Identifier: 10840 Street Address Line 1: 15 Victory Rd Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model:TSM-250 PA05.18 Module Quantity: 32 Array Size (DC watts): 8000.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 41.0 Ibs Module Length: 64.95 in Module Width: 39.05 in Basic Wind Speed: 110.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward: 820 Ibf Lag Bolt Design Load- Lateral: 300 Ibf EcoX Design Load -Downward: 493 Ibf EcoX Design Load - Upward: 568 Ibf EcoX Design Load -Downslope: 353 Ibf EccX Design Load -Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-10): R2 Roof Type: Composition Shingle Average Roof Height: 18.0 ft Least Horizontal Dimension: 13.0 ft Roof Slope: 12.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 1.06 1.06 1.06 Roof Snow Load 35.6 35.6 35.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 11.4 11.4 11.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 35.6 35.6 35.6 psf Downslope:Load Combination 3 7.7 7.7 7.7 psf Down: Load Combination 3 36.4 36.4 36.4 psf Down: Load Combination 5 9.1 9.1 9.1 psf Down: Load Combination 6a 33.0 33.0 33.0 psf Up:Load Combination 7 -10.3 -17.8 -27.4 psf Down Max 36.4 36.4 36.4 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 50.0 50.0 50.0 in Max Spacing Between Attachments With Rafterffruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.7 16.7 16.7 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 30.1 30.1 30.1 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 16.0 16.0 16.0 in Max Cantilever from Attachment to Perimeter of PV Array 10.0 10.0 10.0 in Layout R Skirt o Coupling Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Clamp maximum allowable overhang. Plane Calculations (ASCE 7-10): R1 Roof Type: Composition Shingle Average Roof Height: 18.0 ft Least Horizontal Dimension: 13.0 ft Roof Slope: 43.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.5 0.5 0.5 Roof Snow Load 16.8 16.8 16.8 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 16.8 16.8 16.8 psf Downslope:Load Combination 3 10.0 10.0 10.0 psf Down: Load Combination 3 10.7 10.7 10.7 psf Down: Load Combination 5 13.3 13.3 13.3 psf Down: Load Combination 6a 17.2 17.2 17.2 psf Up:Load Combination 7 -11.4 -13.6 -13.6 psf Down Max 17.2 17.2 17.2 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 79.2 79.2 79.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 26.4 26.4 26.4 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 61.4 61.4 61.4 in Max Spacing Between Attachments With RafterlTruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 20.5 20.5 20.5 in Layout q.. Al a� 4A4 6 V 17 .r [r 10 Skirt e Coupling Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Clamp maximum allowable overhang. Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1312 Ibs Weight of Mounting System: 150 Ibs Total System Weight: 1462 Ibs Total Array Area: 564 ft2 Distributed Weight: 2.59 psf Number of Attachments: 75 Weight per Attachment Point: 19 Ibs Bill Of Materials Part Name Quantity ESEG01CLASA EcoX Clamp Assembly 75 ESEG01 COASA EcoX Coupling Assembly 45 ESEGOISKKTA EcoX Landscape Skirt Kit 4 ESEG01 SKKTA EcoX Portrait Skirt Kit 12 ESEG01CPKTA EcoX Composition Attachment Kit 75 ESEG01 ELASA EcoX Electrical Assembly 2 I