Loading...
5 VICTORY RD - BUILDING INSPECTION -� 1 RECEIVED IN8PECTIGRAL,$ERVICES, The Commonwealth of Massachusetts Board of Building Regulations and Standards �� I�E 3 rj8 Massachusetts State Building Code,780 CMR Revised Mar 2011 Building Permit Application To Construct, Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official lied:Only Building Permit Number: Date ApVlied. �(yr Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION 1.1 Pro erty Address• 1.2 Assessors Map& Parcel Numbers Lla Is this an accepted street. yes .x no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Froposd Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Check if yes❑ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Own�e�.f Decor Name(Print) City,State,ZIP S v c QkM4 rct C1 3 � No.and Street el hone ep Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction X Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ Other ❑ Specify: Brief Description of Proposed Work: S p YW+DV n 1+dtC- Sbl0.r SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: (Labor and Materials) Official Use Only ].Building $ I. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ (a-L� ❑Standard City/Town Application Fee ❑Total Project Cost (Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire Suppression) $ Total All Fees:$ 6.Total Project Cost: $�p I�t Check No. Check Amount: Cash Amount 1 0 l - , ❑Paid in Full ❑Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 -Construction Supervisor License(CSL) 3aw(e,s ��rtPXY�/14Y1 0ense N�J1-� � 2on l9 Exp anon ate Name of CSL Holder 2 I t I cu n List CST,Type(see below) U No.and Street 1 Type Description Sa-u� LCS (\,l Tc Q)9 c)t . U Unrestricted(Buildings u to 35,000 cu.ft. Cityrrown,Star ZIP w R Restricted 1&2 Famil Dwellin (/ M Mason RC Roo fin Coverm WS Window and Sidin � "C ',�L� SF Solid Fuel Burning Appliances flty,_7ry`~D(QY� VIULV�<pn 1 Insulation E Email address Corn D Demolition tered Home Improvement Contractor(HIC) v� r oto_r ve.lo 2Y LAC any Name or HIC Registrant Name HIC Registration Number E pirat on ate N oDeet l� $�D47$13D530 Les Email address Cprvt ,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes.......... No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize VI V I✓1'F SD JCLY' to act on my behalf, in all matters relative to work authorized by this building permit application. Print Owners Nam (Elearonic Signature) Dale SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,1 hereby attest under the pains and penalties of perjury that all of the information contained in th' p i' tion is true and accurate to the best of my knowledge and understanding. v t 0-r- (e -2-1( Print O s r rized Agent's Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.goy/oca Information on the Construction Supervisor License can be found at www.mass.gov/di)s 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number ofdecks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" I CERTIFICATE OF LIABILITY INSURANCE °A n101pMM 01°°"""' ro12o13 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS .CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder Is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHONE FAX No Ert: AIC No: DENVER, 80 34 Attn:Denwrccertrequest@marsh.cem,FaX:212.948.4381 ADDESS INSURE INS)AFFORDING COVERAGE NAIC0 462738-STNDGAWUE-13-14 INSURER A:Evanston Insurance Company 35378 INSURED INSURER a:National Union Fire Insurance Co of PA Vivint Solar,Inc. 4931 N 300 W INSURER C:Navy Hampshire Insurance Company 23841 Prove,UT 84604 INSURER 0: i INSURER E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-002368030-06 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADOL USR POLICY EFF POLICY EXP LTR TYPE OF INSURANCE POLICY NUMBER jMNrGDNYYYj MIMUDYyYyj LIE1nS A GENERAL LIABILITY 13PKGWE00274 11/01/2013 1%1/2014 EACH OCCURRENCE $ 1,000,000 X COMMERCIAL GENERAL LIABILITY 50,000 PREMISES Ea occurrence $ CLAIMS-MADE rxi OCCUR - MED EXP(Any one person) $ 5,000 PERSONAL B ADV INJURY $ 1,000,000 GENERALAGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER - PRODUCTS-COMPX)PAGG $ 2,000,000 X I POLICY PIPCT RO- LOC I $ B AUTOMOBILE LtABIUTY - 9701087 11/01/2013 11/01/2014 COMBINED SINGLE LIMIT 1,000,000 Ea accident E B JX ANY AUTO 9701088 11/01/2013 11/01/2014 BODILY INJURY(Per person) $ AU OS SCHEDULED BODILY INJURY Per acddent $ AUTOS AUTOS ( )HIRED AUTOS N NON-OWNED PROPERTY DAMAGE AUTOS Per acddent $ $ A UMBRELLA UAB X OCCUR 13EFXWE00088 11/01/2013 11/01/2014 EACH OCCURRENCE $ 10,000,000 X EXCESS LIAR CLAIMS-MADE AGGREGATE S 10,000,000 DED RETENT I$ C WORKERS COMPENSATION 029342334; 029342335 111012013 111012014 X WC STATU- OTH- AND EMPLOYERS'LIABILITY C ANY PROPRIETOR/PARTNEWEXECUTIVE YIN .029342336: 029342337 11/01/2013 11/01/2014 1,000,000 OFFICERIMEMBER EXCLUDED? ® NIA E.L.EACH ACCIDENT E C (Mandatory in NH) 029342338 1110112013 1110112014 EL.DISEASE-EAEMPLOYE $ 1,000,000 n yea,descflhe Under DESCRIPTION OF OPERATIONS MI. E.L.DISEASE-POLICY LIMIT $ 1,000,000 A Errors&Omissions& 13PKGW00029 11/01/2013 11/012014 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (Attach ACORD 101,Additional Rerrwrlu Schedule,X more apace Is required) he Cedificata Holder and others as defined in the written agreement ale included as additional insured where required by written contract with respect to General Uability.This insurance is primary and non. ninbutory over any eXisfing insurance and limited 0 liability arising out of the operations of the named insured and where required by written contract.Waiver of submgation is applicable where required by wn8en retract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORUMD REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe ,c hr. fQro/ir� ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 26(2010/05) The ACORD name and logo are registered marks of ACORD 4911 North 30(1 Wes[,Provo,UT 14604 Employer Identification No.: 80-0756438 VIV Ilt. solar.Phone:(377)4044129 Fax:(801)765-5758 Massachusetts HIC License No.: 170848 E-Mail: suppon@vivintwdarcom ij•'j/ ��fn wwwMvintso o' J /Ila'.xm, AR Nli 7T5 .. RESIDENTIAL POWER PURCHASE AGREEMENT This RFSIDF NTIAL POWER PURCHASE AGREEMENT Ithis"AgeremenP)is entered into by and between VIVINT SOLAR DEVELOPER,LLC',a • Delaware lint led liability company('We'."UP',"Our")and the ern tomcpa)CTpau,•Your"),as oflhc Transaction Date set forth below. Full Name(Fbv,xn tau Full Name IFr a..m,m,p Customer(): P' Pryo.�.r:or.,o,vo n„Mint o.�.. ow.ono Telephone No.: 6Mail: Prope Street Address: - Address City,County,State,Zip: )� 1.SERVICES A. DESIG:i AND INSTALLATION. We will design,install,service and maintain a velar planuvollme system on Your Property,which will include all solar panels, nveners,meters,and other components(collectively,the''SysKm'),a further described m the Cuvtmner Packet and the Work Order that We will provide Vou hereafter. All material Poniuns 'I the System will be insmlleJ by Our employed technicians and electricians.and not subcontractors. With Your c operation,We will(i)desgel,install and connect the System in material compliance with all applicable laws;(ii)complem all put sputions;' d(iii)obain all required sanifcanuns and permits. In eider to design a 5yslam that meets Your needs,You agree that We may obtain Vom elmtncal usa a history(rain Your elmtnc utility(the"Udtity')and You shall pmvidc lfs with enpi<s of Your Utility bills as We may reasonably request. Other than th activatinn fee desaihed in Section LB,We will)ddesign and install the System at no cost[o You. B. ACFAV, TI(Irv. ran agree tin pay us a n -time activatinn Cec in the amount ofS We will interconnect the System with[be Utility,and cause the Sv tam m generate are,g�measured in kilowatt hears('kWA"))(the"£tie nsmllxtion of Nis Sysmm generally takes one day and is anticipated w begin and be sidemen ly complete between two(2)and six(6)weeks hared err. C. OWNE SHIP OF SYSTEM. We shall own the System as Our sole personal property. You will have no property interest in the System. D. OPERA PIONS AND MAIN"PENANCE. We will opcmte and maintain the SystemU)at Our vile cost and expense:(if)in good condition;and in material core fiance with all applicable laws and permits and the Utility's requirements. E. INSUR NCE. We carry commercial general liability insurance,workers'compensation insurance,and pmperry instuance on the Sysmm. for more information nceming Ounnsumnec and to obtain acopy ol'Our certificate ofinswaneq pleue visit: www.vrvapsolar.emminsuranec 2.TERYYM,PRICE,PAYMENTS, 2,AANNND�FIN6ANCIAA. T.DISCLOS neir kWhURES p y produced by the System,You us SO wplicable taxes. ill Energy fire dPRICE. shall Y Ein the Cu each cr Paear n, et.Tand 3AfRFFNF.NT ISaIF�ICTTIESALE OF F.NFRC ofme y�emOl1 ND NOT FOR measured inTHE SALEflowalt upF ASOLRRE ERGYDEVICE. T B. TERM. This Agreement shall be effective as of the Transaction Date and continue until the twentieth s)anniversary of the In-Service Data(the v "Term"). Th "1nService Dare"shall be the first Jay alter all of the following have been achieved. (t)the yaem has been installed and is capalife of genennng E rgy,(n)p11 Permits necessary to operate the System have been obmined,(iii)the System has been interconnected with the Utility,tat (iv)all mspecuons a d cendicmes required under applicable law or by the Utility have been completed or remiveJ. C. PAYM NTS. Beginning with the first month following the In-Service Date and throughout the Term We will send You an invoice reflecting the charges for F. ergy produced by the System m the previous month. You shall make monthly payments to Us by automatic ppay�mnent deduction from Your designated ch ckmg=.act err credit card. It is Your responsibility to ensure that there are adequate funds or adequate aedit limit. There is no torment charge same i red with this Agreement For all pa meats more than ten(10)Ron due,We may impose a late charge qua)mTwenty-Five Wllars(S25) and interest a an annual rate of ten percent(I %,,plus applicable taxes. R n continue m fail m make any payment within ten HO)days after We give You written ofirt,Oren We may exe oc all remedies available to Us pursuant to Section 13(b). D. RENEN AT, At the end of the Term,You may elect to fit continue with this Agreement On a year-m-year basis;(it)enter into a new Agreement with Us and cane this Agreema.[,(iii)purchase the System at the end of the Term and cancel the Agncment)the"Purchase Oyrfon"d)or(rvo cancel this Agreement d have r e System removed a[tin mst to You. You will need to notify Us in writing cunceming mr election vixty(60)days prior on, the end of the Term. If You elect Nis Purchase Option,the"Purchase ODdon Price"will be the then-current lair market value oC the System based on an independent pP s is valuation of simiWrly sized phomvulmic s stems in Your eogmphic re ' v. The appraiser's valuation will be provided to You in writing and II be binding. IC We receive Vour per,mrnt of[he Irchase Option rice cosrs oNe appraisal,applicable taxes,and all otM:r amounts then owing and ern aid hereunder We will transfer ownership of ilm System m You at the end of the'ferm on an"As Is,Where Is basis. If Yone lu:r to have the System rcrmr eel,W e will mmove the System from Your Pmppccnyy 'thin ninesy(911)dayys after the end of the Term. IF YOU DO NOT NOTIFY US OF YOUR F.LF. TION TO CANCEL BY SENDING A WWI'TEN NOTICE TO US,THEN THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-T0.VF.AR BASIS UNTIL YOU NOTIFY US IR WRITING OF YOUR RLF.CTION TO CANCF.I.AT LEAST SIXTY(60) DAYS PRIO TO THE END OF THE RENEWAL TERM. E. CREDI 'CHECK. fv connection with the execution of this Agreement and at any time during the"Perm,You hereby authorize Us to(i)obtain Your credit rating it repon from credit reporting aggencies;(it)to report Your payment performance under this Agreement to credit reporting agencies;and (iii)disclose t is and other information m Our ettiliates and actual or prospective lenders,financing parties,investors,insurers,and acquirers. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE (888) 567-8688. SEE PRESCREEN & OPT-OUT NOTICE SECTION 29)BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. 3.LIMITED WARRANTY A. LIMIT4 D INSTALLATION WARRANTY. We mvide a workmanship warranttyy that the System shall be Dec from material dcfmts in design and workmanship wJer nomwl operating conditions for the Term. We further warrant that id, flop penetrations We install shall be watertiPit ht as of the date of installation. c do tut provide any warranty to You with respect to any component of the Syy[cm. Any manufacturer's warranty is mail inn m,not m lieu of,this limi d mstalUnit warranty. This warranty does not cover problems resulting tram exposure to harmful matenafs and chemicals, fire, flood, earthquake,o other acts afgod,vandalism,alteration of system by anyone not militarized by Us,or any other cause beyond Our control. B. MANUFACTURERS'WARRANTIES. The Srlari s solar modules carry a minimum manufacturer's warranty of twenty(20)years as follows: ((a))eluting the first ten(10)Tears of use,the modules'electrical ou[pat will not degrade by more than ten percent(10%)from the originally rated output;and (b)dunnp th first twenty(20)years of use,the modules'electrical output will not det,'rade by more than twenty percent(20%)ttom the onginally rated output. The stem'sinvprers tarty i minimum manufacturer's warranty ofma(10)years against defects or comparison breakdowns. During the Tenn,We will enforce t are warranties m the fullest extent possible. C. DISCL USHER OF WARRANTY. EXCEPT AS SET FORTH IN THIS SECTION 3,WE MAKE NO OTHER WARRANTY TO YOU OR Y NY OTHER PERSON, WHETHER EXPRESS, IMPLIED ORS A'I ­T6'IORY, AS TO THE MERCHANTABILITY OR. FITNESS FOR ANY PURPOSE OF THE EQUIPMENT, INSTALLATION, DESIGN, OPERATION, OR MAINTENANCE OF THE SYSTEM. CHE PRODUCTION OR DELIVERY OF ENERGY, OR ANY OTHER ASSOCIATED SERVICE OR MATTER HERF,UND.R, ALL OF WHICH WE HEREBY EXPRESSLY DISCLAIM. OUR LIABILITY FOR ANY BREACH OF ANY WARRANTY IS LIMITED TO REPAIRING THE SYSTEM OR YOUR PROPERTY TO THE EXTENT REpUIRED UNDER THIS AGREEMENT. YOU ACKNOWLEDGE THAT WE ARE RELYING ON THIS SECTION 3.C.AS A CONDITION AND MATERIAL INDUCEMENT TO ENTER INTO THIS AGREEMENT. THERE ARE NO ACES WHICH EXTEND BEYOND THE DESCRIPTI ON OF THE FACE HEREOF. 4.REMOVAL OF THE SYSTEM You shall not make any Alterations(m defined in gepti�n 9 to the System. If You want to make repairs or improvements to Your Property that require the temporary removal ofthe System or that could inter'fee wrtlt its performance or operation,You must g ve Us at least thirty (30)days'poor written nonce {a"Cusrome Requested Shur own ). Vou agree that any reps"v or improvement to Your Property shall not materially alter Your roo(where the System is install: mtpensatto.for Our removal,storage,and reinstallation of the S stem.You agree to pay m Us a fee equal to Four Hundred and Ninety-Nine Doll (549. be are W e remove the System. You shall be required to pay the hundown Paymant tas defined m Seaton I S)if the S rem is not rcinsnallcd within 0)days of removal In the event of an emergency affecting the System,You shall conWa Us _me tote y. If Resare unable[o timely respond,You yy(at Your own expense)contmet with a licensed and quad. ed solar installer to remove the System as necessary m make repa"vs required by the emergent . Yan shall he responsible for any damage to the Sysmm[hat results from actions taken by Your contractor. S.ARBITRATION OF DISPUTES Most customer concerns can be resolved quick)y and amicably by calling Our customer service department 1 877)4044129. f Our customer se ice de artment is unable to resolve Your concern,You and We agree to resolve any Dis ute as define oug mdrng arbitration o small claims court instead ofcourts of general jurisdiction. BY SIGNING BELOW,YOU(ACKNOWLEDGE AND AGREE THAT(1)Y U ARE HEREBY WAIVING THE RIGHT Tel A TRIAL BY JURY;AND(11)YOU MAY BRING CLAIMS AGAINST US ONLY IN UR INDIVIDUAL CAPACITY,AND NOT AS A PLAINTIFF OR CLASS MEMBER IN ANY PURPORTED CLASS OR REPRESEN ATIVE PROCEEDING. You and We agree toarbitrate all disputes,claims and controversies arising out of or relating to ,a.:nn t'- ai .mrv:.w n'tan�w. pt. -vrn f3ar (i)any aspec of the relationship between You and Us,whdher based in contract,tort,statute or any other legal theorryy;(ii)this Agreement or any other a ement concemmg the sub'ect matter hereof ( ) any breach, default, or termination of this A' cement; and (iv)the mterpretatio validity,or enforceabJity of phis Agreement,including the determination of the scope or applicability of this'Section 5(each,a "Dispute'). nor m commencing arbitratiuo,a patty must first send a written"Notice of Dispute'via certified mad to the ot—cepp rty. The ..�{ r Net of Di pate must describe the nature and asps fur the Dispute and the relief sought If You and We are unable to resolve the Dispute within thirty (30) days, dren either parry may commence arbitration. The arbitration shall be administered by JAMS pursuant to its Streamhne rhrtration Rules and Proce tires availn6le ar. httpp://www.amsadr.cam/mles-streamlined-mbitration,the"JAMS Rules")and under the ml s set forth in this Agreement The arbitrator shall be boun�by the terms of this Agreement No matter the circumstances,the arbitrator shi ntial damages to either party. If You initiate arbitration,You shall be resp nsrble to pa $250. All attorneyys'fees,navel expenses,and other costs of the arbitration shall be bomc by You and Us in accordance vith the IAMS Rules and applicahle law. The arbitmnon shall be conducted at a mutually agreeable location near Your Propertyy. Judgment on an arbitration award maybe entered in any court of competentjurisdietion. Nothing in this Section 5 shall preclude You or We from seeking pmvrsional remedies in aid ufarbitra[ion hum a court o competent jurisdiction. NOTICE:B INITIALING IN THE SPACE,BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE MATTERS INCLUDED IN THE"ARBITRATION OF DISPUTES"PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING LP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE I ITIGA'FED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP YOUR JULICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS ARBITRAI ION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO I SUBMIT D SPUTES ARISING OUT OF THE MA'I"TERS INCLUDED IN THE"ARBITRATION OF DISPUTES"PROVISION TO NEUTRAL ARBITRATION. a:mnrq»m��a: {E UWE AGREE TO ARBITRA"LION AND WAIVE THE RIGHT TO A JURY TRIAL: �,S 6.NOTICE TO CUSTOMERS K 191 A. LISTC F DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement,(ii)the Additional Terms and I Conditions, in the Customer Packet,and IN)the Work Order. These documents are expressly incorporated into this Agreement and apply E to the relatio sip between You and Us. B. IT IS N DT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOTE GOODS INSTALLED UNDER THIS AGREEMENT. C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and receive a legible copy of this Agreement,that We have signed the Agreement,and that You have read and received a legible copy of every docu nt that We have signed during the negotiation. D. DO N(T SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely Bled in copy of this Agreement,signed by both You and Us,before any work may be started. E. YOU N AV CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO THE LATER OF: (1)MIDNIGHT OF THE,THIRD (3ma)BUST qESS DAY AFTER THE TRANSACTION DACE,OR(11)THE START OF INSTALLATION OF THE SYSTEM. SEE THE NOTI E OF CANCELLATION BELOW FOR AN EXPLANATION OF THIS RIGHT. VIVINTS LARD 'LOP L CUSTOMER(S): By: By: Y Printed Na �fl'✓Rf/1 C�'1 _ Printed Name: > d Title: �6�Qr ri �'fClh+ By: V •. ( G-' Printed Name: Transaction Dow: FOR INF RMATION ABOUT CONTRACTOR REGISTRATION REQUIREMENTS, CONTACT THE MASSACHUSETTS OFFICE O CONSUMER AFFAIRS AND BUSINESS REGULATION:TEN PARK PLAZA,SUITE 5170,BOSTON.MA 03116, (617)973-8 00 OR 888-283-3757. .. . _-_-__- -------------------------------------- —---------------------------------------------------------- . NOTICE OF CANCELLATION Transaction ate: AR No.: MAY CANT' NSACCI BLIGATION,WITHIN THREE(3)BUSINESS AY OVE DA E, LATER) N OF TH£ SYSTEM. IF YOU CANCEL, NY PROPERTY TRADED IN,ANY PAYMENT ADE BY YOU UNDER T RACT OR SALE,AND ANY NEGOTIA LE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN (10) BUSINESS DAYS FOLLOW[ 'G RF.CF.IPI' BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING UT OF 1'HE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL,YOU MUST MAKE AVAILABLE.TO THE SELL ,R AT YOUR RESIDF,NCE,IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED,ANY GOODS DELIVER D TO YOU UNDF,R THIS CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUC IONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE'SELLER'S EXPENSE AND RISK IF YOU DO MAKE THE CUODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN ENTY(20)DAYS OF 1'HE DATE OF YOUR NOTICE OF CANCELLATION,YOU MAY RETAIN OR DISPOSE OF THE G ODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GWDS AVAILABLE TU THE SELLER, R IF VOU AGREE TO RETURN TIIF.GOODS TO THE SELLER AND FAIL TO DO SO,TNEN YOU REMAIN LIABLE F R PERFOILMANCE OF ALL OBLIGATIONS UNDER THE.CONTRACT. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNF,D AND DATED COPY OF THIS CANCELLATION NOTICE OR ANY OTHER WRITTEN NOTICE, R SEND A TELEGRAM,TO VIVINT SOLq�t DEVELOPER,LLC,AT 4931 N 300 W,PROVO,UT 84604 PRIOR TO THE LAT R OF: (1)MIDNIGHT OF THE TNIRD(3"'T BUSINESS DAY AFTER THE TRANSACTION DATE,OR(II)THE START U INSTALLATION OF THE SYSTEM. I HEREBY CANCEL THIS TRANSACTION: Date: Customer's Signature: imsm Boston, MA 02114-2017 " wwwv.inass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Vivint Solar Developer, LLC Address:4931 North 300 West City/State/Zip:Provo, UT 84604 Phone#:801-704-9389 Are you an employer? Check the appropriate box: Type of project(required): I I am a employer with 10 4. ❑ I am a general contractor and I employees (full and/or part-time). have hired the sub-contractors 6. ❑ New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have 8. Demolition working for me in any capacity. employees and have workers' [No workers' comp. insurance camp. insurance. t 9. Building addition required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12 ❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.7 Other comp. insurance required.] 'Any applicant that checks box#1 must also Eli out the section below showing their workers'conipensatian policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. •Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees, they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insu,ante for my employees. Below is the policy and job site information. Insurance Company Name:New Hampshire Insurance Comany Policy# or Self-ins. Lic. #:1029�3422l28 ^` Expiration Date:11-01-14 Job Site Address:S � C o � nA City/State/Zip:,j L&I � dq-7-6 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. Pdo hereby cer " under.th-?pai and penalties ofperjury that the information provided above is true and correct. Signature: f Date: Phone#: 801-704-9389 Official use only. Do not write in this area, to be completed by city or town official. City or Town: Permit/License # Issuing Authority(circle one): 1.Board of Health 2. Building(Department 3. City/Town Clerk 4. )Electrical Inspector 5. Plumbing Inspector 11. Other Contact Person: Phone#: Office of Consumer Affairs�d Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Dome Improvement Contractor Registration Registration: 170848 Type: Supplement Card - VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card.Mark reason for change. scot cs 20W0s(11 Address ❑ Renewal Ej Employment Lost Card t�/rC 1(JantmoouOealUi.o�V4Lai9rrM40N.td *F'P"atio ficcofConsumer Affairs&Business Regulation License or registration valid for individul use only ME IMPROVEMENT CONTRACTOR before the expiration date. If found return to: Office of Consumer Affairs and Business Regulation gistration: 170848 Type: 10 Park Plaza-Suite 5170 n: 1/6/2016 Supplement Card Boston,MA 02116 VIVINT SOLAR DEVELOPER LLC. JAMES SHERMAN 4931 NORTH 300 WEST PROVO. UT 84604 Undersecretary Not valid without signature LTM Massachusetts -Department of Public Safety Board of Building Regulations and Standards Construction Sulicrt i.cnr License: CS-045254 JAWS R SfIL,IUMAN 81 MAIN ST t SAUGUS NIA 0106 - Expiration Commissioner 08/28/2014 I WC.ONSULTING Wyssling Consulting 321 West Main Street Boonton, NJ 07005 Scott E. Wyssling, PE, PP, CME office (973) 335-3500 cell(201) 874-3483 fax(973)335-3535 swyssling@wysslingconsulting.com May 30, 2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Reardon Residence 5 Victory Road, Salem MA AR#3147246 9.69 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by Vivint Solar and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal prepared by Vivint Solar identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 8 dimensional lumber at 16" on center. The attic space is partially finished and photos indicate that there was limited access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached ZEP calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B'• and 12, 19 and 40 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B••, Zone 2 per(ASCE/SEI7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 40 PSF=Live Load (ground snow load) • 5 PSF=Dead Load solar Panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "ZEP Code Compliant Installation Manual', which can be found on the ZEP website (zepsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir(North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2', is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 IlF with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four(4) rafter spaces or 64" o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. 4,eryofScott IN tr y N C v r o GIVI y MA Licens 0,50 9O,r FGISTEe FrS10NAL W CONSULTING U C N fn m w mom oQ'z ly_�z NEz C NO Q y0 cu I 1 PV SYSTEM SIZE: I 09.69 kW DC I s OF r PVC CONDUIT N FROM JUNCTION BOX TO ELLC PANEL JUNCTION BOX ATTACHED TO ARRAY USING ZEP ZS-GAB TO ry KEEP JUNCTION BOX OFF ROOF PV INTERCONNECTION POINT, LOCKABLE SWITCH, ANSI METER LOCATION, I I n a 8 UTILITY METER LOCATION o m m p I I vO p v a z m a _—_—_ —___ ___— > a rc a m w w z m 38)Trina Solar TSM-255 PA05.18 MODULES WITH A MIN EnoNase M215-60-2LL-82%ZC MICRO-INVERTER - MOUNTED ON THE BACK OF EACH MODULE SHEET NAME: l U) J a SHEET NUMBER: 5 Victory Rd , Salem MA 01970 PV SYSTEM SITE PLAN o SCALE: 1/16" = T-0" d U LUMBING VENT(S) •� mw IyyEz NEi O y0 Q L Roof Section 3 m RoofAmn :320 N P: R,dM 12 LL �V CHIMNEY V CIRCUIT#1: O 15 MODULES Y l Roof Section 1 •� Roof Azimuth:140 *c= Roof Tilt 40 � J a TIE INTO METER# y. 16416296 V CIRCUIT#2: OMP.SHINGLE 13 MODULES g m o w f W V � E a IL R' K J J � m W Z J Roof Section 2 a RoofA olf,140 0 Raa1TJt 19 SHEET awm NAME: LL- Z VCIRCUIT#3: 1 J 10 MODULES of it SHEET NUMBER: PV SYSTEM ROOF PLAN o • i N SCALE: 1/8"= V-0" d U ao MOUNTING y A ED PV3.0 DETAIL NZ¢2 5ItB'015n1'STAINLESS lif F) LEVELINA(Z�LFSTEEL MR.TOR°UE=1&1 Mhs. > EZMoCOMP MOUN ONOWITHER COMEM UNT U WATERPROORNG SEALWITH COMP MOUNT Q PV MODULE,TYP.MOUNT As nEEoeo TO RAFTERS OF COMP. d SHINGLE ROOF,PARALLEL j WITH PLANE OF ROOF PV ARRAY TYP. ELEVATION STAINLESS STAINLESS STEEL LAG SCREW i TORpUE=15t2 flJhs �'V} NOT TO SCALE A� a U) 909 , �I LEVELING FOOT ON COMP MOUNT PERMITTE°LEVELING I NOT TO SCALE FOOT SPACING �© vF LEVELING FOOT(ZSLFBI •� FRAMING BELOW SHOWN OASHEGFORC—HY SEP COMPATIBLE n WMO°ULE XTBRI°INTERLOCK n Q m o I I I I 0 I B CANTILEVER-L9 L=PERMITTED SPACING Q O l 55 SEE L°OE COMPLIANCE LETTER FORALLOWABLESPACING pXOTOVOLTAIC MODULE > Z Of C n I I I I JJLO I I I zZ � � SHEET INTERLOCK(2SIlB( HYBRID INTERLOCK NAME: LEVELING F°°T(ZS{FB) �ROOFFGAMUNG N LEVELING F00T USA-FB) Z J V 0 w INTERLOCK a LLB, FOOT IPV SYSTEM MOUNT DETAIL SHEET FOOT SPACING NUMBER: ( : '� O MODULES IN PORTRAIT/LANDSCAPE SCALE 3I8"=1'-0" C) 1 NOT TO SCALE a Inverter Ratings(Guide Section 4) Conduit and Conductor Schedule nvetler MakelModel Enphase M21S6[i S2r-ZC Tag Deam ion W. Gauge pot ConEutlon ConEun Type ConEUX Sax, DETAIL IMo.DC van Rating <s Vmte Max PI lg<0-C 215 were t Enphase engage able-THWN-2 12 AwG a NIA-Fedor NIA-Frea a, Nominal AC Voltage 2.0 vice 1 Bart Copper Ground lEGUGEC) 6AWG 1 NIA-Free Air NIA-Free Pit V Trine Solar TSM-255 PAO5.18 Max AC current 0.9 Amps 2 THwrv2 10AWG g Pvc g•-1• no SOLAR MODULE Max ocl=o sating 20 Ampe Mao Number of PanelalCiavil 17 2 THWN.2-Ground BAWG 1 PVC 0'-1' 3 THWN2 aAWG 3 PVC 0'-1' NOTES FOR INVERTER CIRCUITS(Guido Secppnfiand 9l: BAWG W. 0'-1' C^A`ymW 3 THWN2-Ground 1 Wi 1.)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS PV Module Ratings @ STC(Guide Section 6) W 2<i SWITCH MEET THE REQUIREMENTS? Model MakelModdl TMa solar TSM-255 PACS 18 0 l— EnphasaM21&60.2LL-52x-ZC YES NO %NA Max Power PointCurrent(imp) 8.36 Amps ��m, MICRO-INVERTER AT 2)IF GENERATION METER REQUIRED.DOES THIS METER Max Power-Point Voltage loom) 30S Volts 0 h O EACH MODULE,ATTACHED SOCKET MEET THE REQUIREMENTS] Open Circuit (Vac) 3T7 vans -0 WITH ZEP HARDWARE YES NO %NA Shon-Circuit Cermot Ine) 0.92 Amps L >> 3.)SIZE PHOTOVOLTAIC POWER SOURCE DO)CONDUCTORS Max Sends F.. OCPO) 15 Amps F BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power at STO Pmax) 255 Wafts RATING AT DISCONNECT. Maximum System Voltage tDMIECN600(UL) N aJ SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Vac Temperature Coefficient -0.32 MICROINVERTER CONNECTION TO INVERTER OCPD AMPERE RATING(See Guide Section 9). TO ENGAGE TRUNK CABLE V 5JTOTAL OF 3 INVERTER OCPD(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Appendix DI: PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY �! WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean scheme NEC 690 NSX2ga)] RYES NO dry bulb temperature for ASHRAE location most similar to installation location: -19-C Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb (GROUNDING ARRAY) xrr 66BARE GROUND l temperature for ASHRAE location most simllarto installation location: 39°C Sign for inverter OCPO and AC Discerned: 3J 2005 ASHRAE fundamentals Springs. 44.1'Cn temperatures do not exceed aT°C in the United States(Palm Springs.CA is least 0 Y a For less than 9csnent-carrying design tors Sutler um System AC Point ofConnection oar-mur of 7-mitrless(at Iaaslted above nor and wing and outdoor design AC OutpN cunent as z9ggo0 Amps temperature of 4)°C or less(all of United States). • Nominal AC Voltage xvi value a.)12 AWG,90°C conductms are generally acceptable for modules with Ise of 7,68 Amps PV CIRCUIT 1: 15 MODULES/PARALLEL THIS PANEL FED BY MULTIPLE SOURCES or less when protected by a 12-Amp or smaller rose. N ItIr a are erally (UTILITY AND SOIAR) b.)10 an Pro ca by 15-Amp or smaller for modules with Ise of 9.5 Amps 5 a • • O O or less when Pro a15-Am p mailer fuse. •� a 1 ENVOY BOX da i PV CIRCUIT 2: 13 MODULES/PARALLELed e RwP ¢ ed no m v 13 Q i POINT OF DELIVERY o C E 1.o I AND INTERCONNECTION z m J` • • • �` �' > E U HOUSE EXTERIOR of of m ---- ----y COMBINER VISIBLE/LOCKABLE to w z m 1 PANEL J J w z 1 SREC/ANSI 'KNIFE'A/C r r a PV CIRCUIT 3: 10 MODULESIPARALLEL METER DISCONNECT EXISTING ENTRANCE z z , a 20A CONDUCTORS SHEET t0 • .t k11A RATED:2p0A NAMEE 1.0SUPPLY-SIDE NOLAR TAP Z 2 J` • • • N J` j Ec 70512P) J Ut 240V/200A Q ____ ____ _____ _______ _________ _______ ______ __ _ ___ • K PANEL p VisionMetenng Siemens I SHEET V2S-25 IfLNF222R _ NUMBER 2 3 3 60AI240V 3 TO EXISTING E 1.0 E1.0 E1.0 FUSED E1.0 LOAD-CENTER O JUNCTION BOX NEMA3 NOTE-NEUTRAL CONDUCTOR(S)OMITTED FOPoVI)INyRI&YjERSIBLE N80-2T1WFFff9$IOUTPUT CIRCUITS WILL HAVE APd21111MULMNDUCTOR UU Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: David Reardon j Project Address: 5 Victory Rd,Salem VIA A.System Description: The array consists of a 9.69 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(38) 255-watt modules and(38)215-watt micro-inverters,mounted on the back of each PV module.The array includes (3)PV circuit(s).The array is mounted to the roof using the engineered racking solution from Zep Solar. B.Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98`F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A. System Description: 1.Roof type: Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Zep Solar b.Product Name: ZS Comp c.Total Weight of PV Modules and mounting hardware: 1786 Ibs d.Total number of attachment points: 77 e.Weight per attachment point. 23.19 Ibs/square foot E.Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 669.18 square feet h.Array pounds per square foot: 2.66 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (13)modules,(27)attachments 22.62 pounds per square foot -Roof section 2: (10)modules,(18)attachments 26.11 pounds per square foot -Roof section 3: (15)modules,(32)attachments 22.03 pounds per square foot vivinw#. solar 3. Electrical Components: A. Module (UL 1703 Listed) Qty Trina TSM 255-PA05.18 38 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp-rated voltage at maximum power - 30.5 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.36 amps Ise-rate short circuit current - 8.92 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-2LL-S22 38 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max. start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 3 PV circuit 1 - 15 modules/inverters (20) amp breaker PV circuit 2 - 13 modules/inverters (15) amp breaker PV circuit 3 - 10 modules/inverters (15)amp breaker vivint. solar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 13.5 amps Continuous current adjustment factor 125% 2011 NEC Article 705.60(B) PV circuit continuous current rating 16.875 amps 2. Overcurrent protection device rating PV circuit continuous current rating 16.875 amps Next standard size fuse/breaker to protect conductors 20 amp breaker Use 20 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampaciry derate) a.Temperature adder Average high temperature 38.4'C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Table 310.15(B)(3)(c) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Table 310.15(B)(2)(a) Adjusted PV circuit continuous current 23.7 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 9 conductors Conduit fill derate factor 70% 2011 NEC Tzblc 310.15(B)(3)(a) Final Adjusted PV circuit continuous current 33.9 amps Total derated ampacity for PV circuit 33.9 amps Conductors(tag2 on 1-line)must be rated for a minimum of 33.9 amps THWN-2(90°C) 410AWG conductor is rated for 40 amps (Use#tOAWG or larger) 2011 NEC Table 310.15(B)(16) 4.Voltage drop(keep below 3%total) 2 parts. 1.Voltage drop across longest PV circuit micro-inverters (from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.31"/o The largest number of micro-inveners in a row in the entire array is 8 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.31 %. 2.AC conductor voltage drop: =I x R x D C 240 x 100 to convert to percent) = (Nominal current of largest circuit)x (Resistance of#10AWG copper)x(Total wire run) = (Circuit 1 nominal current is 13.5 amps)x (0.0012652)x (130�-(240 volts)x(100) 0.92% Total system voltage drop: 1.23% vivint. solar p� EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 153 Street Address Line 1: 5 Vicrtory Rd Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer:Trina Solar Module Model: TSM 255-PA05.18 Module Quantity: 38 Array Size (DC watts): 9.69 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 41.0 Ibs Module Length: 64.95 in Module Width: 39.05 in Basic Wind Speed: 100.0 mph Ground Snow Load:40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Fully Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load -Lateral: 300 Ibf EcoX Design Load - Downward: 707 Ibf EcoX Design Load- Upward: 764 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load - Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 50 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-05): Section 2 Roof Type: Composition Shingle Average Roof Height: 18.0 ft Least Horizontal Dimension: 18.0 ft Roof Slope: 19.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 30.2 30.2 30.2 psf Slope Factor 0.93 0.93 0.93 Roof Snow Load 28.1 28.1 28.1 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -15.4 -23.3 -36.0 psf Net Design Wind Pressure Downforce 8.2 8.2 8.2 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -15.4 -23.3 -36.0 psf Design Wind Pressure Downforce 8.2 8.2 8.2 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 28.1 28.1 28.1 psf Downslope: Load Combination 3 9.4 9.4 9.4 psf Down: Load Combination 3 27.3 27.3 27.3 psf Down: Load Combination 5 10.4 10.4 10.4 psf Down: Load Combination 6a 27.2 27.2 27.2 psf Up:Load Combination 7 -14.1 -22.0 -34.7 psf Down Max 27.3 27.3 27.3 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 62.8 62.8 55.8 in Max Spacing Between Attachments With RafterlTruss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 20.9 20.9 18.6 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 48.7 48.7 43.2 in Max Spacing Between Attachments With Rafterrrruss Spacing of 16.0 in 48.0 32.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.2 16.2 14.4 in Layout Skirt e Coupling 0 Clamp Plane Calculations (ASCE 7-05): Section 3 Roof Type: Composition Shingle Average Roof Height: 18.0 ft Least Horizontal Dimension: 18.0 ft Roof Slope: 12.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 30.2 30.2 30.2 psf Slope Factor 1.06 1.06 1.06 Roof Snow Load 32.1 32.1 32.1 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -15.4 -23.3 -36.0 psf Net Design Wind Pressure Downforce 8.2 8.2 8.2 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -15.4 -23.3 -3fi.0 psf Design Wind Pressure Downforce 8.2 8.2 8.2 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 32.1 32.1 32.1 psf Downslope: Load Combination 3 7.0 7.0 7.0 psf Down: Load Combination 3 32.9 32.9 32.9 psf Down: Load Combination 5 10.5 10.5 10.5 psf Down:Load Combination 6a 31.4 31.4 31.4 psf Up: Load Combination 7 -14.0 -21.9 -34.6 psf Down Max 32.9 32.9 32.9 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 57.2 57.2 55.8 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 19.1 19.1 18.6 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 44.4 44.4 43.3 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 32.0 32.0 32.0 in Max Cantilever from Attachment to Perimeter of PV Array 14.8 14.8 14.4 in 1 11 1- I�I I Plane Calculations (ASCE 7-05): Section 1 Roof Type: Composition Shingle Average Roof Height: 18.0 ft Least Horizontal Dimension: 18.0 ft Roof Slope: 40.0 deg Truss Spacing: 16.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 30.2 30.2 30.2 psf Slope Factor 0.55 0.55 0.55 Roof Snow Load 16.6 16.6 16.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -15.9 -18.9 -18.9 psf Net Design Wind Pressure Downforce 15.4 15.4 15.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -15.9 -18.9 -18.9 psf Design Wind Pressure Downforce 15.4 15.4 15.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 16.6 16.6 16.6 psf Downslope: Load Combination 3 9.7 9.7 9.7 psf Down: Load Combination 3 11.5 11.5 11.5 psf Down: Load Combination 5 17.2 17.2 17.2 psf Down:Load Combination 6a 20.7 20.7 20.7 Psf Up:Load Combination 7 -14.8 -17.8 -17.8 psf Down Max 20.7 20.7 20.7 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 72.3 72.3 72.3 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 24.1 24.1 24.1 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 56.0 56.0 56.0 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 18.7 18.7 18.7 in Layout Skirt Coupling 0 Clamp Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 1558 Ibs Weight of Mounting System: 154 Ibs Total System Weight: 1712 Ibs Total Array Area: 669 ft2 Distributed Weight: 2.56 psf Number of Attachments: 77 Weight per Attachment Point: 22 Ibs Bill Of Materials Part Name Quantity ESEG01 CLASA EcoX Clamp Assembly 77 ESEG01COASA EcoX Coupling Assembly 49 ESEG01 SKKTA EcoX Landscape Skirt Kit 6 ESEG01 SKKTA EcoX Portrait Skirt Kit 17 ESEG01 CPKTA EcoX Composition Attachment Kit 77 ESEG01 ELASA EcoX Electrical Assembly 3 fit..