Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
83 VALLEY ST - BUILDING INSPECTION (3)
�t. rs,5w _ c The Commonwealth of Massachusetts ;Y' Board of Building Regulations and Standards CITY OF iR Massachusetts State Building Code,780 CMR SALEM Revised Mar 1011 i Building Permit Application To Construct, Repair,Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only ._ Building Permit Number: Date Applied: Building Official(Print Name) Signature Date SECTION 1:SITE INFORMATION - yy1..1�1 Property Address• 1.2 Assessors Map&Parcel Numbers I.1 a Is this an accepted stree� no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use Lot Area(sq ft) Frontage In) 1.5 Building Setbacks(R) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Municipal❑ On site disposal system ❑ Check if yesO SECTION 2: PROPERTY OWNERSHIP' 2.1 owlnfo�ia Trmerson Salem MA 01979 Name(Print) City,State,ZIP 83 valley st 9782994534 Robensu@gmail.com No,and Street Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK2(check all that apply) New Construction Existing Building❑ Owner-Occupied ❑ 1 Repairs(s) ❑ 1 Alteration(s) ❑ I Addition ❑ Demolition ❑ I Accessory Bldg.❑ Number of Units_ Other ❑ Specify: Brief g es ription of Proposed Work': U SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials) 1.Building $ l (0 -(O Q 1. Building Permit Fee:$ Indicate how fee is determined: ❑Standard City/Town Application Fee 2.Electrical ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5. Mechanical (Fire $ -Suppression) Total All Fees:$ Check No._Check Amount: Cash Amount:_ 6.Total Project Cost: $ l 0 Paid in Full 11 Outstanding Balance Due: 9 f SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) — k tivLicense Number Exmt lc Na g UT ' S�er I I G ULisl CSL Type(see below) ll No.it treet ` Type Description 1 I o o/'�!+�{�'I k A'LLl �, J) U Unrestricted(Buildings u to 35.000 cu.ft.) City/�Fown,State,/IP ' l A,S //UU - vts R Restricted 1&2 FamilyDwelling M Masonry RC Roofing Coveting WS Window and Siding SF Solid Fuel Burning Appliances I Insulation Telephone I Email address D Demolition 5.2 Registered Home' Immpprovv/e�1`mvent Contractor(HIC) 1' q/ - I I� \1-,1 _l-1 U�^- r HIC I/Reeggisstration Number Expiration Date HIC Company Nan r}I IC R istrant Nam 1` o- ywlfl{:CO�tf r014 No.and Street , ,I,,f l`I .-�ti s Email address City/Town,State,ZIP 1 �Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ........ No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize )h VL :_\Q/.i!.0 to act on my behalf,in all matters relative to work authorized by this building permit application. —,4� � 10/19/2016 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNEW OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding. Print O ers or Authorize Agent' Name(Electronic Signature) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A.Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/dps 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basementlattics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost' t AC40 CERTIFICATE OF LIABILITY INSURANCE o127=66DYYYn THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT NAME: MARSH USA INC. 122517TH STREET,SUITE 1300 acNr o M No DENVER,CO 60202-5534 ADDRESS: Attn:Denver.Cer Request@marsh.com I Fax:212-946-4361 INSURE S AFFORDING COVERAGE NAIC0 WSURERA:ADs Specialty Eumpe INSURED Vvint Solar,Inc: INSURERS:Zurich American Insurance Company 1653$ Vvint Solar Developer LLC INSURER C:American Zurich Insurance Company 40142 Vvint Solar Provider LLC INSURER D:NIA WA 3301 North Thanksgiving Way,Suite 500 Lehi,UT 64043 INSURER E NSUPeR F: COVERAGES CERTIFICATE NUMBER: SEA-G02920007-12 REVISION NUMBER:O THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL UBR POLICY EFF POLICYEXP LmR TYPE OFINSURIINCE POLICY NUMBER MMIDD/YYYY MMU LIMITS A X COMMERCIAL GENERAL LIABILITY 3776500116EN 011292016 0112912017 EACH OCCURRENCE s 25,000.000 DAMAGE TO RENTED CLAIMS-MADE L-J OCCUR PREMISES Ea ocaunence $ 1,000,000 MED EXP(Arty one pare m) $ 10,000 PERSONAL B ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 25,000,ODO X POLICY PRO F7 LOC PRODUCTS-COMP/OP ADD $ 25,000,000 OTHER $ B AUTOMOBILE UIBILITY BAP509601601 11/0112015 11"1/2,1, COMBINED SINGLE LIMIT s 1,000,000 Eaacadent X ANY AUTO BODILY INJURY(Per person) S ALL OWNED SCHEDULED AUrOS AUTOS BODILY INJURY(Per accident) S X HIREDAUTOS % NON-OWNEDPROPERTY DAMAGE S AUTOS Per amicant Comp/Coll Dad $ 1,000 OCCUR UMBRELLA ULB EACH OCCURRENCE $ EXCESS UAB CLAIMS-MADE AGGREGATE s DEO I I RETENTION$ Is C WORKERS COMPENSAMON WC509601301 11/0112015 111012016 X PER orH- ANDEMPLOYERS'DABILfTY YINOFFICE STATUTE ER ANY PROPRIETOR/PARTNER/EXECUTIVE AZ,CA,CT,HI,MD,NJ,NY,NV,NM, E.L.EACH ACCIDENT $ 1,000,000 (Mandatory InN )EXCLUDED? � NIA (Mandatory In NH) OR,PA,UT E.nd .L.DISEASE-EA EMPLOYE E 1,D00,000 B Uyes RIPTdescIOe OF WC509601401 MA 11/01/2015 11/01/2016 Or OF OPERATIONS OeIow ( I E.L.DISEASE-POLICY LIMIT $ 1,W0,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES (ACOflD 101,AddlUonal Remarks Schedule,nay ba attached U more apace b mquire0) The Certificate Holder and others as defined in the written agreement are included as additional insured where required by writen contract with respect to General Liability.This insurance is primary and non- contributory over any exlsbng insurance and limited to liability arising out of the operations of the named insured and where required by written contract.Waiver of subrogation s applicable where required by within contract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem - SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe ,7Zr, JQEalso @ 1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014101) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachasens Department of IndustrialAccidents Office of Investigations 1 Congress Street,Suite 100 Boston,MA 02114-1017 www.massgov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Aaolicant Information Please Print L@Wbly Name(Business/Organization/Individual): V I V i n-t S Q G Y— Address: k 80O W A-9, fh-t( Lon City/State/Zip: ��'l� � I�Phone#: �0 ` �Z �y Are you an employer?Check the appropriate box: Type of protect(required): I.X I am a employer with �3(o 4. ❑ I am a general contractor and I employees(full and/or part-time). a have hired the sub-contractors 6. ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees These sub-contractors have g. ❑Demolition working for me in any capacity. employees and have workers' [No workers'comp. insurance comp. insurance? 9• ❑Building addition required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their I I.❑ Plumbing repairs or additions myself. [No workers'comp. right of exemption per MGL insurance required.]t c. 152,§I(4),and we have no 12.❑ Roof repairs employees.[No workers' l3�Other sO comp.insurance required.] *Any applicant that checks box e 1 must also till out the section below showing their workers'compensation policy information t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit Indicating such. tContrachus that check this box must attached an additional sheet showing the name of the sub•convactors and state whether or not than entoies have employees. If the subcontmcmrs have employees,they most provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below Is the policy and fob site information. Insurance Company Name:` n ,M� S t( `\ ,^,�n S./y-'cam Policy#or Self-ins.Lic.#:�V�Cy; 50q �0-(O' ( ?0 )- Expiration Date: ZO��A� Job Site Address:��lJ1 �,� �I \ City/State/Zip. 1 "\q Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as requu ed under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insulance coverage verification. /do hereby cacti er the nand enaBJes ofperu that the in ormadon provided above Is true and correct Signtire: IDatel one#' 2 Z� Offlclal use only. not w ihLs area,to be completed by city or town off7ciaL City or Town: Permit(License# Issuing Authority(circle one): 1.Board of Health 2. Building Department 3.CityfTown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: &Xe. anz iz,��trltC>6rcc�c�ellr O#rice of Consumer Affairs end-8usinessRegulation 10 park Plaza-Suil: 5170 Boston, Massachusetts 02, 116 Home Improvement,*Contractor Registration e• •; �; Repletratlon: 170848 Type: Supplement Card s�VIVINT SOLAR DEVELOPER LLC.,,)° - Expiration: 1/5/2018 a KYLE GRE ENE 3301 N THANKSGIVING WAY,SUl. S.6.1 17, 70 -- — - LEHI, UT 94943' ;UpdpleA'JJress and reruru nerd:Il7arR eaesoa far chap OCA1 0 2M-0911 [I AJrfrep Ij Renewal ❑Empleyment El Lost Card 1 6r =settsDepartment of Fubfic Safety , uildi►a Regulations � .t� !15 and $t�,,f�1ff/s Jcense: CS-108068 KYLE GREENE r 44 MAIN STREET ° North Reading MR 0� Ajl r � E.Xptr7t141' * ConvOissioner 01120/2018 p M RESIDENTIAL SOLAR POWER PURCHASE AGREEMENT �� V �Y IiY���ly��'J��r.Solar� Customer Name and Contact Information: Transaction Date Name(s) Gloria Emerson Service No.2016-10-08 Installation Location Address 83 Valley St Approximate Start and 83 Valley St Salem MA 01970 Completion Date Salem Home Phone 9794760339 2017-04-06 MA 01970 Cell Phone 9784760339 E-Mail melrose1414@aim.com Our Promises + We will design,install, maintain,repair, + We will not place a lien on Your Property. monitor,and insure the System at no additional cost to You. + You are free to cancel this Agreement any time prior to Our commencement of + We warranty all of Our work,and that Our installation work at Your Property. roof penetrations will be watertight,for the initial 20 year term. + The Energy Price includes a$5 monthly discount for paying by automatic debit + Your Energy Price will not increase by more from Your bank account. than 2.9%per year. + You will not be responsible for any + After five years,if You need to make property tax assessed on the System. Property repairs,We will remove and + We will fix or pay for any damage We may reinstall the System if You pay Our estimated costs. cause to Your Property or belongings. Your Commitment • Pay for the Energy produced by the System. • Maintain a broadband internet connection. • Keep Your roof in good condition throughout • Continue service with Your Utility for any the Term. energy used above and beyond the System's production. • Respond to Our sales and support teams when scheduling and completing paperwork. At the End of Your Initial Term ' You can renew the Agreement • You can request that We remove the System for a subsequent term; at no additional cost. • You can purchase the System;or If You Move ' We guarantee You can transfer the • You can relocate the System to Your Agreement to the new owner,regardless of new home;or credit rating; • After the sixth anniversary,You can purchase _ • You can prepay the Agreement; the System. Vivint Solar Developer, LLC(EIN: 80-0756438) is a licensed contractor in each state in which we operate,for information about our contractor licenses please visit www.vivintsolar.com/licenses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN &OPT-OUT NOTICE BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: support@vivintsolar.com I vivintsolar.com 1800 W Ashton Blvd., Lehi, UT 84043 Phone 87T404.4129 I Fax 801.765.5758 ) Cipyright O 2016 Vivint Solar Developer,LLC All Rights Reserved PPA(8/2016,v3.2.2`,I Page 1 SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. INCORPORATED DOCUMENTS. These documents G. You have the right to require Us to have a are incorporated into this Agreement and apply to the performance and payment bond. relationship between You and Us: (1) Residential Solar H. CUSTOMER'S RIGHT TO CANCEL. YOU MAY Power.Purchase Agreement, (2) Exhibit A: Notice of CANCEL THIS CONTRACT AT ANY TIME BEFORE THE Cancellation, (3) Exhibit B: State Notices and LATER OF: (1) MIDNIGHT OF THE THIRD (31RD) Disclosures, (4) Exhibit C: Certificates of Insurance, BUSINESS DAY AFTER THE TRANSACTION DATE, OR and (5) Customer Packet. (II) THE START OF INSTALLATION OF THE SYSTEM OR B. WE HAVE NOT GUARANTEED, PROMISED OR ANY OTHER WORK WE PERFORM ON YOUR OTHERWISE REPRESENTED ANY REDUCTION IN PROPERTY. IF YOU WISH TO CANCEL THIS CONTRACT, ELECTRICITY COSTS IN RELATION TO THE SYSTEM YOU MUST EITHER: (1) SEND A SIGNED AND DATED THAT WILL BE INSTALLED ON YOUR PROPERTY. WRITTEN NOTICE OF CANCELLATION BY MAIL, E-MAIL, C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES OR FAX; OR (2) PERSONALLY DELIVER A SIGNED AND UNLAWFULLY OR COMMIT ANY BREACH OF THE DATED WRITTEN NOTICE OF CANCELLATION TO: PEACE TO REMOVE GOODS INSTALLED UNDER THIS VIVINT SOLAR DEVELOPER, L-C, 1800 W ASHTON AGREEMENT. BLVD, LEHI, UT 84043, ATTN: PROCESSING D. DO NOT SIGN THIS AGREEMENT BEFORE YOU DEPARTMENT. IF YOU CANCEL THIS CONTRACT HAVE READ ALL OF ITS PAGES. You acknowledge that WITHIN SUCH PERIOD, YOU ARE ENTITLED TO A FULL You have read and received a legible copy of this REFUND OF YOUR MONEY. REFUNDS MUST BE MADE Agreement, that We have signed the Agreement, and WITHIN 10 DAYS OF OUR RECEIPT OF THE g g that You have read and received a legible copy of every CANCELLATION NOTICE. SEE THE ATTACHED NOTICE document that We have signed during the OF CANCELLATION FOR AN EXPLANATION OF THIS negotiation. RIGHT. DO NOT SIGN BELOW UNLESS WE HAVE GIVEN E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TO YOU THE"NOTICE OF CANCELLATION". A SALES REPRESENTATIVE. I. Unless You are provided with a longer period in F. DO NOT SIGN THIS AGREEMENT IF THIS Exhibit A,You may not terminate this Agreement after AGREEMENT CONTAINS ANY BLANK SPACES. You are three(3) business days of the Transaction Date. If You entitled to a completely filled in copy of this seek to cancel thereafter, then You will forfeit any Agreement, signed by both You and Us, before any amounts previously paid and You may owe Us the work may be started. Default Payment. VIVINT SOLAR DEVELOPER, L^LC CUSTOMER(S): Signature: Signature: Q �~-I Printed Name: Serge Didenko Printed Name Gloria Emerson Salesperson No.: Date: 2016-10-08 Date: 2016-10-08 Signature: Printed Name: Date: 2016-10-08 Copyright© 2016. Vivint Solar Developer, LLC. All Rights Reserved. PPA(812016,v3.2.2)JPage 18 N_ pp� C7 0ry� {I 0 1800 W Ashton Blvd. CC77 Stt7rulc�ltllllural Group Lehi, UT 84043 Jon A Ward, SE, PE Clint C. Karren, PE Structural Engineering Manager Structural Engineering Manager Jon.wardL7a vivintsolar.com clint.karren@vivintsolar.com October 28, 2016 Mr. Dan Rock, Project Manager Vivint Solar 1800 W Ashton Blvd. Lehi, UT 84043 Re: Structural Engineering Services Emerson Residence 83 Valley St, Salem, MA S-5289128; 4.24 kW; MA-01 6.47 kW Existing System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a representative from our office under my supervision identifying specific site information including size and spacing of members for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. 5. Previous structural evaluation for the existing solar system completed by Vivint Solar on April, 8 2015. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of the following: • Roof Section 1: Roof section is composed of 2x8 dimensional lumber at 16" on center with 2x6 collar ties every 32" and a single layer of roofing. The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof members. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. The existing roofing material consists of composite shingle. Stability Evaluation: A. Wind Uplift Loading 1. Calculations for uplift are based on ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, a wind speed of 100 mph based on Exposure Category B and 30 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure B, Zone 2 per(ASCE/SEI 7-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. Page l of V v v iv 1n0. B. Loading Criteria 8 PSF = Dead Load (roofing/framing) 40 PSF=Ground Snow Load 3 PSF = Dead Load (solar Panels/mounting hardware) Total Dead Load= 11 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code with Massachusetts Amendments. Analysis performed on the existing roof structure utilizing the above loading criteria indicates that the existing members will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual", which can be found on the Ecolibrium Solar website (www.ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 Yi' thick and mounted 41/2" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the National Design Specifications (NDS) of timber construction specifications for Spruce-Pine-Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than the maximum allowable per connection and therefore is adequate. 4. Roof Section 1: Considering the roof slopes, the size, spacing, condition of the roof, the panel supports shall be placed at and attached no greater than every fourth roof member as panels are installed perpendicular across members and no greater than the panel length when installed parallel to the members (portrait). No panel supports spacing shall be greater than four (4) spaces or 64"o/c,whichever is less. 5. Panel support connections shall be staggered to distribute load to adjacent members. Based on the above evaluation, with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code with Massachusetts Amendments, current industry standards and practice, and the information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. �AA4 OF { ' Regards, N P G Jon P. Ward, SE, PE AN MA License No. 52584 A " No. 525 e RFQI5TE ►�SS/ONAL Page 2ol2 ) vivint. I EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 5289128 Street Address Line 1: Street Address Line 2: City: State: Zip: Country: System Info Module Manufacturer:Jinko Solar Module Model: JKM265P-60 Module Quantity: 16 Array Size (DC watts):4240.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: SolarEdge Technologies Inverter Model: v.SE3800A-US (240V) Project Design Variables Module Weight: 41.88778lbs Module Length: 64.960665 in Module Width: 39.0551392 in Basic Wind Speed: 100.0 mph Ground Snow Load:40.0 psf Seismic: 1.5 Exposure Category: B Importance Factor: I Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load - Upward: 820 Ibf Lag Bolt Design Load-Lateral: 288 IV Module Design Moment—Upward: 3655 in-lb Module Design Moment— Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 ) • EcolibriumSolar Plane Calculations (ASCE 7-10): North East Roof 3 Roof Shape: Edge and Corner Dimension:4.075600479902856 ft Attachment Type: Stagger Attachments: Yes Average Roof Height: 25.0 ft Include Snow Guards:Yes Least Horizontal Dimension: 40.7560047990286 ft Include North Row Extensions: No Roof Slope: 30.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 26.9 26.9 26.9 psf Slope Factor 1.0 1.0 1.0 Roof Snow Load 26.9 26.9 26.9 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift . -20.7 -24.3 -24.3 psf Net Design Wind Pressure Downforce 19.4 19.4 - 19.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -20.7 -24.3 -24.3 psf Design Wind Pressure Downforce 19.4 19.4 19.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load. 2.4 2.4 2.4 psf Snow Load 26.9 26.9 26.9 psf Downslope: Load Combination 3 12.8 12.8 12.8 psf Down: Load Combination 3 22.2 22.2 22.2 psf Down: Load Combination 5 13.7 13.7 13.7 psf Down: Load Combination 6a 25.9 25.9 25.9 psf Up: Load Combination 7 -11.2 -13.3 -13.3 psf Down Max 25.9 25.9 25.9 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 64.5 64.5 64.5 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 64.0 64.0 64.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.5 21.5 21.5 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 49.7 49.7 49.7 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 16.6 16.6 16.6 in EcolibriumSolar Layout Skirt o Coupling End Coupling Note: If the total width of a continuous array exceeds 35 ft, break *o Clamp array to allow for thermal expansion and contraction. See © End Clamp Installation Guide for details. ® North Row Extension Warning: PV Modules may need to be shifted with respect to roof 0 Row-to-Row Bonding Clip/Bonding Jumper trusses to comply with maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 16 Weight of Modules: 670 Ibs Weight of Mounting System: 60 Ibs Total Plane Weight: 730 Ibs Total Plane Array Area:282 ft2 Distributed Weight: 2.59 psf Number of Attachments: 30 Weight per Attachment Point: 24 Ibs Roof Design Variables Design Load - Downward: 918 Ibf Design Load - Upward: 720 Ibf Design Load - Downslope:460 Ibf Design Load -Lateral: 252 Ibf EcolibriumSolar Bill Of Materials Part Name Quantity ES10260 EcoX Row-to-Row Bonding Clip 4 ES10121 EcoX Coupling Assembly 15 ES10146 EcoX End Coupling 8 ES10103 EcoX Clamp Assembly 18 ES10136 EcoX End Clamp Assembly 12 ES10144 EcoX Junction Box Bracket 1 (Optional) ES10132 EcoX Power Accessory Bracket 16 ES10333 PV Cable Clip 80 ES10334 4 PV Cable Clip 32 ES10195 EcoX Base, Comp Shingle 30 ES10197 EcoX Flashing, Comp Shingle 30 PV SYSTEM SIZE: 4.240 kW DC JUNCTION BOX ATTACHED TO ARRAY USING ECOX TO m 30'OF 1"PVC CONDUIT KEEP JUNCTION BOX OFF ROOF a a FROM JUNCTION BOX TO ELEC PANEL �_—_ _ O __ —_—_—___ _—_— PV INTERCONNECTION POINT,INVERTER, f— &LOCKABLE DISCONNECT SWITCH,& I _� C) UTILITY METER LOCATION;TIE INTO Q METER#25066390 c } F E i 0 i •; m F cn♦♦�� 8 co . O I I spa 00 I GF SHEET NAME: (16)Jinko Solar JKM265P-60 MODULES WITH (16)SolarEdge P300 Optimizer EXISTING ON THE BACK OF EACH MODULE. F J SOUR N a SHEET NUMBER' O PV SYSTEM SITE PLAN SCALE:118"=1'-0" d tl E TIE INTO METER# 25066390 OMP.SHINGLE ♦ 4 NM EM e 1 s ' ssa z C PLUMBING VENT(S IRCUIT#1: Roof Section 1 y a 16 MODULES Roof Azimuth:51 _ Roof Tilt:30 SHEET„ NAME. LL Z i 0a SHEET NUMBER: O i PV SYSTEM ROOF PLAN (V SCALE:1W"I-0" d MOUNTING oJUDER LEAP SPRING DETAILGLIDER TRUT PUT ~ PV MODULES,TVP.MOUNT LEASHER OF COMP SHINGLE ROOF, .uS" SHINGLES PARALLEL TO ROOF PLANE PV ARRAY TYP. ELEVATION HOT TO SCALE MOUNT DETAIL - ECOX WITH METAL FLASHING 0�q NOT TO SCALE wI c CLAMP+ CANTELEVER U4 OR LESS ATTACHMENT a COUPLING L=PERMITTED CLAMP e SPACING SEE CODE COMPLIANT E ECO LETTER FOR MAX ALLOWABLE COMPATIBLE CLAMP SPACING. MODULE _ COUPLING � CLAMP+ PERMITTED e s a CLAMP CLAMP ATTACHMENT SPACING COUPLING PHOTOVOLTAIC MODULE 's m � u g C w a SHEET L=PORTRAIT NAME: -- — CLAMP SPACING ECO Z COMPATIBLE O w L=LANDSCAPE MODULE 2 p CLAMP SPACING SHEET (MODULES IN PORTRAIT/LANDSCAPE PV SYSTEM MOUNTING DETAIL NOMOBER NOTTOSCALE NOT TO SCALE M a Conduit Conductor Schedule(ALL CONDUCTORS MUST BE COPPER) Tag# Wire Conduit Conduit Description Gauge #of Conductors/Color Type Size I� rve,m��� U,stIn9 mwrterTvx 1 PV Wire 10 AWG N/A-Free. N/A-Free g� 2E a T.pll e.111a.n�Sz.ze zBA 2(V+,V-) Air Air Mneu,e m.�� E.aa"B MneU.T,P Bare Copper Ground N/A-Free N/A-Free & 3a xs TU.IT5MxS5POW.W 1 Bond(EGC/GEC) 6AWG 1BARE Air Air e ' € S `E m 2 THWN-2 30 AWG 2(1V+,1V-)R/B PVC 1" _ 1 2 15 2 THWN-2-Ground Bond 8AWG SGRN PVC 1" 3 THWN-2 10 AWG 3(111,1L2 IN)B/R/W PVC 1" N 3 THWN-2-Ground Bond 8AWG 1GRN PVC 1" G 4 THWN-2 2/0 AWG 3(11-1,1L2 IN)B/R/VJ PVC 11/2" rn.. 10 125Ax240V 4 THWN-2-Ground Bond 6AWG 1GRN PVC 11/2" Combiner Panel y_ O � 16 PV MODU LES PER INVERTER=4240 WATTS STC (n o_ 1 STRING OF 16 PV MODULES HOUSE EXTERIOR } m VISIBLE/LOCKABLE MILBANK EXTERIOR 'KNIFE'A/C 100AOR VISIBLEILOCKABLE DISCONNECT �� v JUNCTION SDI( AI EQUIVALENT 'KNIFE' C WITH RRFAERSIBLE U5934-XL.BLG DISCONNECT �� c GROUND SPLICE — REM 9 M I 30A � EXISTING SoIAREOGE LI�N ENTRANCE F300 OPTIMIZERS L - n E --- -- -- CONDUCTORS SOLAREOGE SREC/ANSI SIEMENS60AI240V SIEMENS60AI240V - I M g 8 P m RATED:200A I.RIAm METER UNFUS 22 NEMA3 FUSED NE IVAGF222R R g e p 1 w Rrea- NF222R OR OR EQUIVALENT POINT OF z W ? EQUIVALENT Tm, INTERCONNECTION w SIX EDGE S,,..OpomNRe i OCS"PETv z.ovmnEuseorvEM"B LOAD-SIDE $ M' rCH OR EOUI KENT i SOLAR TAP SWI NEC 705.12(D)(2) I � _ EXISTING SHEET N 240V/200A AC wNAME. LOAD-CENTER o � v¢IRLE WITH 1-20A FUSED w 4 2 _ `NNNIIEN ///��E 1z5" DISCONNECT 4 Z 3 DW.NNECT = TO BUS S4 JO J Q MINIMUMGEL SSE N 4 AWGCQPPER SHEET NUMBER'. CD "CONFORMS TO ANSI C32.1-2008 CONFORMS TO NEC 2014 :<e o�slvza LLI Design Conditions: Calculations: ROOFTOP CONDUCTOR AMPACITIES DESIGNED IN COMPLIANCE WITH NEC 690.8,TABLES Breaker calculations dependent upon inverter Continuous Maximum Output. a 310.15(B)(2)(a), 310.15(B)(3)(a), 310.15(B)(3)(c), Wire Gauge Calculated from NEC code 310.15(B)(16)with ambient temperature calculations from NEC 310.15(2)(a) a s 310.15(B)(16),CHAPTER 9 TABLE 4, 5,&9. using the 90*C column(On Roof)or 75*C column(Off Roof),*310.15(B)(3)(c)for 1/2" minimum clearance of the a LOCATION SPECIFIC TEMPERATURE OBTAINED conduit above the roof and 310.15(B)(3)(a)Adjustment factor for current-carrying conductors in a raceway. r f' FROM ASHRAE 2013 DATA TABLES. -When a wire is upsized in the conduit conductor table,voltage drop adjustments were made w i SE380OA-US-U Max Output= 15.83A x 1.25(NEC code 210.19(A)(1)(a))=19.80A. ASHRAE 2013 (on roof): 10 gauge wire rated for 40A x 0.76 (ambient+*22*C)x 1 (fill derate of 2 current-carrying conductors)= 30.40 > Highest Monthly 2% DB Design Temp 32.5°C. 18.75A(Max optimizer output per circuit 15A x continuous duty uprating 125%). Lowest Min. Mean Extreme DS -23.9°C (off roof): 10auge g wire rated for 35A x(Off roof temperature derate; Only applies if derate is< .85) 35.00A> 19.80 (ma DC Safety Switch: System Specs: Solar PV System AC Point Of Connection Rated for max operating condition of Max DC Voltage 500V AC Output Current t6 p g 9 Acceding to Nec 19.8 Amps O inverter NEC 690.35 compliant Nominal DC Operating Voltage 350V 690.8(B)(1) `opens all ungrounded conductors Max. DC Current per String 15A Nominal AC Voltage 240 Volts y Nominal AC Current 15.8A THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) Cc .> Optimizer Solar Edge P300 PV Module Rating @ STC DC Input Power 300 Watts �' e 8 Model Make/Model JKM265PP-60 DC Max Input Voltage qg Volts s Max Power-Point Current(Imp) 8.44 Amps DC Max Input Current 12.5 Amps Max Power-Point Voltage(Vmp) 31.4 Volts DC Max Output Current 15 Amps Open-Circuit Voltage(Voc) 38.6 Volts Max String Rating 5250 Watts ' Short-Circuit Current(ISE) 9.03 Amps Inverter Make/Model SE380OA-US 9 § R Max Series Fuse(OCPD) 15 Amps CEC Efficiency 98 % z w = Nominal Maximum Power at STC(Pmax) 265 V%/C Continuous Max Output Current 16 Amps AC Operating Voltage 240 Volts Maximum System Voltage 1000 V DC(IEC) = DC Maximum Input Current 13 Amps - Voc Temperature Coefficient -0.3 s Am Short Circuit Current 17.5 P rNUMBER. Max Output Fault Current 17.5 A/20ms Other Notes W