Loading...
43 VALLEY ST - BUILDING INSPECTION (3) 5L55 G1= 4z-rg The Commonwealth of Massachusetts / Board of Building Regulations and Standards CITY� M/ Massachusetts State Building Code, 780 CMR S Revised Mar 2011 Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only Building Permit Number: Date Appf14 Building Official(Print Name) Signature a DaYefl SECTION 1: SITE INFORMATION c c-t 470 1.1 Property Address: � p 1.2 Assessors Map&Parcel Numbers r �t 1.1 a Is this an accepted street?yes no Map Number Parcel Number Nm 1 j� 1.3 Zoning Information: 1.4 Property Dimensions: _ u_ Zoning District Proposed Use Lot Area(sq ft) Frontage(ft) ran 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Zone: _ Outside Flood Zone? Public❑ Private ❑ Check if yes❑ Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 owbcottDanford Q 1076 Name(Print) I City,State,ZIP �' \I 3�h 1. 0 3 No.and Street ,� Telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORIe(check all that apply) New Constructio Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ 1 Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units Other ❑ Specify: Brief Descripfi of r osed W kz: In SECTION 4: ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only Labor and Materials 1. Building $ 1. Building Permit Fee: $ Indicate how fee is determined- 2. ❑ Standard City/Town Application Fee 2. Electrical $ V ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4. Mechanical (HVAC) $ List: 5. Mechanical (Fire Suppression) $ Total All Fees: $ S Go Check No. Check Amount: Cash Amount: 6. Total Project Cost: $ 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Cons ruction Sup isor License(CSL) 4 16 License Number Ex iration Date Name of L e List CSL Type(see below) No.and Street Type Description U Unrestricted(Buildings up to 35,000 cu. ft. .�IAAV�. 1 R Restricted l&2 Family Dwelling City/Town,State,`$ M Maxonry RC Roofing Covering WS Window and Siding SF Solid Fuel Burning Appliances u L,f�ii I Insulation Telephone Email address D Demolition 5.2 Registered Monne Impro y�nt ntractor(HIC) HIC Registration Number Expiration Date HIC Compan a IC a is t Name No.and Street Email address City/Town,Sta Telephone SECTION 6: WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance f the building permit. Signed Affidavit Attached? Yes .......... No........... ❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the subject property,hereby authorize Vivi nt Solar to act on my behalf, in all matters relative to work authorized by this building permit application. Sip -4- 9& 7-6-2015 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application,,A 75ed accurate to the best of my knowledge and understanding. I1 Print Owner's or Authorized Agprs Name(Electronic Signature) Date NOTES: l. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L. c. 142A. Other important information on the HIC Program can be found at www.mass.gov/oca Information on the Construction Supervisor License can be found at www.mass.gov/d�s 2. When substantial work is planned,provide the information below: Total floor area(sq. ft) (including garage,finished basement/attics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" The Commonwealth of Massachusetts Department of IndustrialAccidents p ice of Investigations I Congress Street,Suite 100 V" / Boston,MA 02114-2017 www maass.gov/dia Workers' Compensation Insurance davit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibiv, er, LLC Name (Business/Organization/Individual): Vivint Solar Developer, Address:3301 North Thanksgiving Way, Suite 500 City/Statei.Z_ip: Lehi, UT 84043 Phone#:801-377-9111 Are you an employer? Check theappropriate box: Type of project(required): 1.® I am a employer with 1® 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition working for me in any capacity. employees and have workers' coin insurance. 9. ❑ Building addition [No workers' comp. insurance P� required.] 5. We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 L❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no 13. Other Solar Installation employees. [No workers' comp. insurance required.] 'Any applicant that checks box NI must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins. t . WC 509601300 /1/2015 Expiration Date: (' Job Site Address: �r City/State/Zip: Am OX17 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofperjury that the information provided gLayg g tr a and correct. Si-anature: /� �i 7?��� Date Phone#: 801-2296459 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Flealth 2. Building Department 3. City/'town CI®rk 4. Electrical inspector 5.Plumbing Inspector 6.Other Contact Person:, Phone#: I (77he Office of Consumer Affairs ftnd Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Dome Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card_Mark reason for change. scA 1 G 20M-MlI Address Renewal Employment Lost Card Massachusetts -Department of Public Safety Board of Building Regulations and Standards Construction Supen'isor 0 License: CS-W254 ' JAIMES R smw*4 N 6 Fox Hollow " {I ' SAUGUS MA MR* i Expiration OS/28/2016 Commissioner (MWD A CERTIFICATE OF LIABILITY INSURANCE DATE 1013,201412014 YYYI THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHONE FAX rt: A/C No: DENVER,CO 80202-5534 E- L Attn:Denver certrequest@marsh.com,Fax:212.948.43BI ADDRESS: INSURE S AFFORDING COVERAGE NAICIf 46273B-STNDGAWUE-14-15 INSURER A:Evanston Insurance Company 35378 INSUREDVivint Solar,Inc: INSURER B:Zurich American Insurance Company 653 15 Mvint Solar Developer LLC INSURER c:American Zurich Insurance Company 40142 3301 North Thanksgiving Way Suite 500 wsuRER D Lehi,UT 94043 wsUREa E: INSURER F: COVERAGES CERTIFICATE NUMBER: SEA-00236803G-08 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUBR POUCYEFF POLICY EXP LTR TYPE OF INSURANCE IO POLICY NUMBER MMDIYYYY MMID LIMITS A GENERAL LIABILITY 14PKGWE00274 11/01/2014 11/01/2015 EACH OCCURRENCE $ 1,000,000 X DAM—AGE RENT D 50,000 COMMERCIAL GENERAL LIABILITY PREMISES Ea oocunence $ CLAIMS-MADE M OCCUR NED EXP(Any one person) $ 5,000 X $5,000 Ded.BI&PD PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMPIOPAGG $ 2,000,000 POLICY X PR0. LOC $ B AUTOMOBILE LIABILITY BAP509601500 11/012014 IV012015 COMBINED SINGLE LIMIT 1,000,000 Ea accident Ix ANY AUTO BODILY INJURY(Per person) S ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS HIRED AUTOS X NON-OWNED PROPERTY DAMAGE $ AUTOS Per acddem $ A UMBRELLA,4AB X OCCUR 14EFXWE00088 11/012014 111012015 EACH OCCURRENCE $ 5,000,000 X EXCESS LIAR AGGREGATE AGGREGATE $ 5,000,000 DED I I RETENTIONS $ C WORICERS COMPENSATION WC509601300 11/0112014 11/01/2015 w>:sraru- EB B AND EMPLOYERS•LIABILITY YIN WC509601400 11/01/2014 11/01/2015 1,000,000 ANY PROPRIETORPARTNER/EXECUTIVE E.L.EACH, E OFFICERIMEMBER EXCLUDED? NIA (Mandatory In NH) EL DISEASE-EA EMPLOYE S 1,000,000 D es,describe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Ertors&Omissions& 14PKGWE00274 11/0112014 11/01/2015 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (Adaeh ACORD 101,AddWorul Ru m ria Schedule,R more apace Is required) The Certificate Holder and others as defined in the written agreement ale included as additional insured where required by written contract with respect to General Lability.This insurance is primary and non- contributory over any existing insurance and limited to liability arising out of the operations of the named insured and where required by written contract.Waiver of submgadon is applicable where required by written wnbect with respect to General Liability and Workers Compensation. _ CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTIIOWED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsloe ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD .M 3301 N.Thanksgiving Way,Ste.500,Lehi,UT84043 Employer Identification No.: 80-0756438 VIV'nt• O Phone:.(8777 4044--4129 Fax:(801)765-5758 Massachusetts HIC License No.: 170848 E-Mail: su o vivintsolaccom Ly, ^ l o�O S . --• www.vivintsolac :com - AR No. RESIDENTIAL POWER PURCHASE AGREEMENT This RESIDENTIAL POWER PURCHASE AGREEMENT(this "AgreemenP) is entered into by and betweenVIVINT SOLAR DEVELOPER, LLC, a Delaware limited liability company("We","Us","Our")and the undersigned Customer(s)("You", `Pour"),as of the Transaction Date tforth ow. Full Name(Frrv,no.Last h' ProP er 0.er: Yes' No (/�a/ l�///Y Full Name(First.MI LasQ CBSIOIiler(S). Property Owmer: Yes ❑No Telephone No.: -� E-Mail: , M/ Property Street Address: t Address: City,County,State,Zip: r 1.SERVICES A. N. solar panels,reverterIt s Nmete-rs,and It it comeponen[s on (�o�lecUwe install service the"System"maintain, sutther d solar escribed in photovoltaic system Customer Your Packet Property, which will Work Order thateWe WithpYourecooperratone Werw l llO design'install aI the SystemheiS ytemsinIlcd by Oterialur mpl oyed tec hnicia all s and elec alwsnss,and not subcontractors. quired inspections;and(iii)obtain al]required certaielifications and Permits. In order to design a System that meets Your needs,You agree that We may oallbtain Your electrical usage history from Your electric utility(the"Utility")and You shall provide Us with copies of Your Utility bills as We may reasonably request. .O'ther than the activation fee described in Section LB,We will design and install the System at no cost to You. B. to You agree to pay Us a one-time activation fee in the amount of$ cause the System to generate energyy measured in kilowatt hours (`kWh")) (the "Enerrgygy• . Installation of ll the System tgenerhe allymtakeshone days ar)and d is anticipated to begin and be subsrannally complete between two(2)and six(6)weeks tin eatter. fic C. OWNERSHIP A SYSTEM. We shall own the System as Our sole personal property. You will have no property interest in the System. in OPERATIONS AND MAINTENANCE. We will operate and maintain the System(i)at Our sole cost and expense;(ii)in good condition;and(iii)in material compliance with all applicable laws and permits and the Utility's requirements. in INSURANCE. We carry commercial general liability insurance,workers' compensation insurance,and properrt[yy insurance on the System. For more information containing Our insurance,and to obtain a copy of Our certificate of insurance,please visit: www.vivintsolar.com/insurance. 2.TERM,PR[CE,PAYMENTS,AND FINANCIAL DISCLOSURES A. ENERGY PRICE. For all Energy produced by the System,You shall a $0.The Energy Price shall increase each year by two and nine-tenths cite per kWh the"Energy Price") plus applicable taxes. will be provided to You in the Customer Packet. THIS AGREE p A oo fart estimate of the System output,measured in kilowatt hours A SOLAR ENERGY DEVICE. MENT IS HE SALE OF ENERGY BY US TO YOU AND NOT FOR THE SALE OF B. TERM, This Agreement shall be effective as of the Transaction Date and continue until the twentieth(20th)anniversary of the In-Service Date(the "Term'). The`In-Service Date"shall be the first day after all of the following have been achieved: (i)the System has been installed and is capable of generating Energy,(ii)all permits necessary to operate the System have been obtained,(iii)the System has been interconnected with the Utility,and(iv)all inspections and certificates required under applicable law or by the Utility have been completed or received. C. PAYMENTS. Beginningg with the first month following the In-Service Date and throughout the Term, We will send You an invoice reflecting the charges for Energy produced by the System in the previous month. You shall make monthly payments to Us by automatic payment deduction from Your designated checking account or credit card. It its yYour responsibility to ensure that there are adequate funds or adequate credit limit. There is no financin5g) and sorest associated with annual Ira c of ten per ant(1eement. For 10°/P),plus apPl cab more le taxe ten sl0)dayon cons past tinue to failto make myose a tpay payment within to(10)days Twenty-FivefterlaWe give You written notice,then We may exercise all remedies available to Us pursuant to Section 13lb1. D. RENEWAL. At the end of the Term,You may elect to O continue with this Agreement on a year-to-year basis;(ii)enter into a new Agreement with Us and cancel this Agreement; (iii)purchase the System at the end of the Teri and cancel this Agreement the "Purchase Option"), or(iv)cancel this A reement and have the System removed at pt cost to You. You will need to notify Us in writing conceming the election sixty(60)days prior to the end o£the Tenn. If You elect the Purchase Option, the "Purchase Option Price" will be the then-curent flair market value of the System based on an rode endem a%miser's valuation of similar) sized photovoltaic systems in Your geographic region. The appraiser's valuation will be provided to You in writing n °Wih'b-C+Bind'tngrlFWe 'OUT -of-the•P.urchase O We will transf, ptionXiee costs of=the appraisal,applicable taxes,and all other amounts then and We will re'move the er System from Your Propper System within mnetyt the(90)enJ its ysfthe after the on an of the Term.WhereF YOU DONOT NOTIFY have US OF YOUR ELECTION TO CANCEL BY SENDING A WR TEN NOTICE TO US, THEN THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS UNTIL YOU NOTIFY US IN WRITING OF YOUR ELECTION TO CANCEL AT LEAST SIXTY(60) DAYS PRIOR TO THE END OF THE RENEWAL TERM. E. CREDIT CHECK. In connection with the execution of this Agreement and at any time during the Tern,You hereby authorize Us to(i)obtain Your credit rating and report from credit reporting aggencies;-(ii)to report Your payment performance under this Agreement to credit reporting.agencies;.and (iii)disclose this and other information to Our affiliates and actual or prospective lenders,financing parties,investors,insurers,and acquirers. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING "PRESCREENED" OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE (888) 567-8688. SEE PRESCREEN & OPT-OUT NOTICE (SECTION 29)BELOW FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. 3.LIMITED WARRANTY A. LIMITED INSTALLATION WARRANTY. We provide a workmanship warranty that the System shall be free from material defects in design and workmanship under normal operating conditions for the Term. We further warrant that all rooftop penetrations We install shall be watertight as of the date of installation. We do not provide any warranty to You with respect to any component of the Syystem. Any manufacturer's warranty is in addition to,not in lieu of, this limited installation warranty This warranty does not cover problems resulting from exposure to harmful materials and chemicals, fire, Flood, earthquake,or other acts of god,vandalism,alteration of system by anyone not authorized by Us,or any other cause beyond Our control. B. MANUFACTURERS'y WARRANTIES. The System's solar modules carry a minimum manufacturer's warranty of twenty (20)) years as follows: a during the first ten(10)years of use,the modules'electrical output will not degrade by more than ten Percent(10%)from the on malCy rated output;and u during the first twenty(20)years of use,the modules' electrical output will not degrade by more than twenty percent from the originally rated output. The System's inverters carry a minimum manufacturer's warranty often(10)years against defects or component breakdowns. During the Term,We will enforce these warranties to the fullest extent possible. C. DISCLAIMER OF WARRANTY. EXCEPT AS SET FORTH IN THIS SECTION 3, WE MAKE NO OTHER WARRANTY TO YOU OR ANY OTHER PERSON, WHETHER EXPRESS, IMPLIED OR STATUTORY *AS TO THE MERCHANTABILITY OR FITNESS FOR ANY PURPOSE OF THE EQUIPMENT, INSTALLATION, DESIGN, OPERATION, OR MAINTENANCE OF THE SYSTEM, THE PRODUCTION OR DELIVERY OF ENERGY, OR ANY OTHER ASSOCIATED SERVICE OR MATTER HWARRANTY IS LIMITED TO EREUNDER, ALL OF WHICH WE HEREBY EXPRESSLY DISCLAIM. OUR LIABILITY FOR AN EXTENT Y BREACH OF ANY AGREEMENT. YOU ACKNOWLEDGE THAT WE ARE G THE SYSTEM OR THIS SECTION 3.CUR PROPERTY TO EAS A CONDITION AND MATERIAL INDUCEMENT TO ENTER INTO THIS AGREEMENT. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. - - - 4.REMOVAL OF THE SYSTEM p the temporary removal of the Styistem or that could mteriere with its perfomiamicelor ooper[ion tYouamustpgave or Usiat leas[thirty(to Your sProperty p or y that ha nreq require (a"Customer-Requested Shutdown"). You agree that any repair or improvement to Your Pro e shall Y mstalle m ensa[ion for Our removal,storage,and reinstallation of the System You agre Le oppay to Uss cater equal to Four Hundred and Ninety-Nine Dollars $499 afore We remove the System. You shall be required to ay the Shutdown Payment(as defined in Section IS o the System is not reinstalled within tmRy(30) days of removal. In the event of an emergency affechn the System, You shalt) contact Us imme late y. h We are unable reinstalled timely , respond,You may(at Your own expense)contract with a licensed and qualif ed solar installer to remove the System as necessary to make repairs required by the emergency. You shall be responsible for any damage to the System that results from actions taken by Your contractor. 5.ARBITRATION OF DISPUTES Most customer concerns can be resolved quick)y and amicably by calling Our customer service department at (877) 404-4129. If Our customer service department is unable to resolve Your concern,You and We agree to resolve any Dispute(as defined below)through binding arbitration or small claims court instead of courts of general.l'urisdiction. BY SIGNING BELOW, YOU ACKNOWLEDGE AND AGREE f THAT(I)YOU ARE HEREBY WAIVING THE RIGHT TO A TRIAL BY JURY;AND(II)YOU MAY BRING CLAIMS AGAINST US ONLY IN YOUR INDIVIDUAL CAPACITY, AND NOT AS A PLAINTIFF OR CLASS MEMBER IN ANY PURPORTED CLASS OR REPRESENTATIVE PROCEEDING. You and We agree to arbitrate all disputes, claims and controversies arising out of or relating to oPYriEM L+)01?Vfvini S°Wr f>rvcleper,U.C.All Nlr)nx R�rvcA. MASIAL UlKI T1 PPA/n_.Rl (i)any aspect of the relationship between You and Us,whether based in contract,tort,statute or any other legal theory;(ii)this Agreement or any other agreement concerning the subject matter :hereof; (iii) any breach, default, or termination of this Aggreement; and (iv)the interpretation,validity,or enforceability-of this.Agreement,including the determination of the scope or applicability of�this Section 5(each,a "Dispuze"). Prior to commencing arbitration,a party must first send a written"Notice of Dispute"via certified mail to the oft rep party. The Nohce of ispute must describe the nature and basis for the Dispute and the relief sought. If You and We are unable to resolve the Dispute .within thirty (30) days, then either party.may commence arbitration. The arbitration shall be administered by JAMS pursuant to its Streamlined Arbitration Rules and Procedures available at: http://www.jamsadr.com/rules-streamlined-arbitration,the"JAMS Rules") and under the.rules set forth in this Agreement. The arbitrator shall be bound by the terms of this Agreement. No matter the circumstances,the arbitrator shall not award punitive, sppecial, exemplary, indirect, or consequential damages to either party. If You initiate arbitration You shall be responsible to pay $250. All attorneys' fees, travel expenses, and other costs of the arbitration shall be home by You andUs in accordance with the JAMS Rules and appplicable law. The arbitration shall be conducted at a mutually agreeable location near Your Property. Judgment on an arbitration award may be entered-in any court of competent jurisdiction. Nothing in this Section 5 shall preclude You or We from seeking provisional remedies in aid of arbitration from a court of competent jurisdiction. NOTICE:BY INITIALING IN THE SPACE BELOW YOU ARE AGREEING TO HAVE ANY DISPUTE ARISING OUT OF THE MATTERS INCLUDED IN THE "ARBITRATION OF DISPUTES"PROVISION DECIDED BY NEUTRAL ARBITRATION AS PROVIDED BY APPLICABLE LAW AND YOU ARE GIVING UP ANY RIGHTS YOU MIGHT POSSESS TO HAVE THE DISPUTE LITIGATED IN A COURT OR JURY TRIAL. BY INITIALING IN THE SPACE BELOW YOU ARE GIVING UP YOUR JUDICIAL RIGHTS TO DISCOVERY AND APPEAL. IF YOU REFUSE TO SUBMIT TO ARBITRATION AFTER AGREEING TO THIS PROVISION, YOU MAY BE COMPELLED TO ARBITRATE. YOUR AGREEMENT TO THIS ARBITRATION PROVISION IS VOLUNTARY. YOU HAVE READ AND UNDERSTAND THE FOREGOING AND AGREE TO SUBMIT DISPUTES ARISING OUT OF THE MATTERS INCLUDED IN THE "ARBITRATION OF DISPUTES" PROVISION TO NEUTRAL ARBITRATION. FINE AGREE TO ARBITRATION AND WAIVE THE RIGHT TO A JURY TRIAL: Cnst mens initials: 6.NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT: (i)this Agreement, (ii) the A rd, Terms and Conditions,(iii)the Customer Packet,and(iv)the Work Order. These documents are expressly incorporated into this Agreement and apply to the relationship between You and Us. B. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISES UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS.AGREEMENT. C. DO NOT SIGN THIS AGREEMENT BEFORE YOU HAVE READ ALL OF ITS PAGES. You acknowledge that You have read and received a legible copy of this Agreement, that We have signed the Agreement, and that You have read and received a legible copy of every document that We have signed during the negotiation. D. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both You and Us,before any work may be started. (E. YOU MAY CANCEL THIS TRANSACTION AT ANY TIME((PRIOR TO THE LATER OF: (I))MIDNIGHT OF THE THIRD THE NOTICE OF USINESSCANCELLATION AY AFTER BELOW OR AN EXNSACTION P A NATION O**i THIS THE START OF INSTALLATION OF THE SYSTEM SEE VIVINT SOLAR DEVELO R,LLC CUSTOMER By: By:Printed Name: Printed NameTitle: 6r By:Printed Name Transaction Date: FOR INFORMATION ABOUT CONTRACTOR REGISTRATION REQUIREMENTS, CONTACT THE MASSACHUSETTS OFFICE OF CONSUMER AFFAIRS AND BUSINESS REGULATION: TEN PARK PLAZA, SUITE 5170, BOSTON, MA 02116, (617)973-8700 OR 888-283-3757. - -X----------------------------- NOTICE OF CANCELLATION Transaction Date: AR No.: YOU MAY CANCEL THIS TRANSACTION, WITHOUT ANY PENALTY OR OBLIGATION, WITHIN/THREE (3) BUSINESS DAYS OF THE ABOVE DATE, OR (IF LATER) UNTIL THE START Or. rn ION HF YSTEM IF YOU CANCEL,ANY PROPERTY TRADED IN,ANY PTT`TS-fGCA"QE t3Y YUU UNDER THE C NTRA TOR ,AND ANY NEGOTIABLE INSTRUMENT EXECUTED BY YOU WILL BE RETURNED WITHIN TEN '(10) BUSINESS DAYS FOLLOWING. RECEIPT BY THE SELLER OF YOUR CANCELLATION NOTICE, AND ANY SECURITY INTEREST ARISING OUT OF THE TRANSACTION WILL BE CANCELLED. IF YOU CANCEL, YOU MUST MAKE AVAILABLE TO THE SELLER AT YOUR RESIDENCE, IN SUBSTANTIALLY AS GOOD CONDITION AS WHEN RECEIVED, ANY GOODS DELIVERED TO YOU UNDER THIS CONTRACT OR SALE, OR YOU MAY, IF YOU WISH, COMPLY WITH THE INSTRUCTIONS OF THE SELLER REGARDING THE RETURN SHIPMENT OF THE GOODS AT THE SELLER'S EXPENSE AND RISK. IF YOU DO MAKE THE GOODS AVAILABLE TO THE SELLER AND THE SELLER DOES NOT PICK THEM UP WITHIN TWENTY (20) DAYS OF THE DATE OF YOUR NOTICE OF CANCELLATION, YOU MAY RETAIN OR DISPOSE OF THE GOODS WITHOUT ANY FURTHER OBLIGATION. IF YOU FAIL TO MAKE THE GOODS AVAILABLE TO THE SELLER, OR IF YOU AGREE TO RETURN THE GOODS TO THE SELLER AND FAIL TO DO SO, THEN YOU REMAIN LIABLE FOR PERFORMANCE OF ALL OBLIGATIONS UNDER THE CONTRACT. TO CANCEL THIS TRANSACTION, MAIL OR DELIVER A SIGNED AND DATED COPY OF THIS CANCELLATION NOTICE NC ANY OTHER WRITTEN NOTICE,OR SEND A TELEGRAM,TO VIVINT SOLAR DEVELOPER,LLC,AT 4931 N 300 W PR ANVO,UT HER PRIOR TO THE LATER OF: (I) MIDNIGHT OF THE THIRD (31dD) BUSINESS DAY AFTER THE TRANSACTION DATE, OR (II) THE START OF INSTALLATION OF THE SYSTEM. I HEREBY CANCEL THIS TRANSACTION: Date: Customer's Signature: Z�onr;lhi k'2i113 Vivini Solnr lA:veloper,ei.C_ Ml Nlgha Reserves, Mns'se:'i NseriA PFA{4.E CI' i C7 oll {I tl o so I a r 3301 North Thanksgiving Way, Suite 500 Structural Group Lehi, LIT 84043 P: (801) 234-7050 Scott E. Wyssling, PE Head of Structural Engineering sco tt.wyssfingC&vivin tsolar.com June 22, 2015 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Hanford Residence 43 Valley St, Salem MA S-4410203 13 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit/Verification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2x6 dimensional lumber at 24" on center. Based on the span of the existing rafters, a knee wall or purlin must be installed prior to the installation of the solar panels. The interior knee wall or purlin shall be placed within 12" of an interior wall below the attic space. The attic space is unfinished and the photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. The existing roofing material consists of composite asphalt shingles. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 22 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure "B", Zone 2 per (ASCE/SE17-10). vivi t. solar Page 2 of 2 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. B. Loading Criteria 10 PSF = Dead Load roofing/framing 40 PSF = Live Load (ground snow load) 5 PSF = Dead Load solar panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures and in accordance with the 2009 International Residential Code. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manua!', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable or deflect non- uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1 I/V thick and mounted 4 1/2' off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher that 6" above the existing plane of the roof. 3. Maximum allowable pullout per lag screw is 205 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Spruce-Pine-Fir assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/z", is less than the maximum allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2"with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts will be adequate with a sufficient factor of safety. 4. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every other roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than two (2) rafter spaces or 48" o/c, whichever is less. 5. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, with appropriate panel anchors being utilized and the addition of a knee wall or a purlin, the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is in conformance with the 2009 International Residential Code, current industry standards and practice, and based on information supplied to us at the time of this report. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. A ly yours, ZN OF� t � ir Scott E. Wyssli PE avI MA License No. 505 0 50 - FGISTEQ� FSSIONM- eudont. solar PV INTERCONNECTION POINT,INVERTER, 5'OF 1"PVC CONDUIT a) o m LOCKABLE DISCONNECT SWITCH, FROM JUNCTION BOX TO ELEC PANEL y Q 2 I A , ANSI METER LOCATION, I A f z 'V B UTILITY METER LOCATION JUNCTION BOX ATTACHED TO .�evj O ARRAV USING ECO HARDWARE TO KEEP JUNCTION BOX OFF ROOF O m 0 r CQ c I PV SYSTEM SIZE: E 13.000 kW DC I I • m r � . ^, (50)Tnna Solar TSM-260 PD05.08 MODULE a W ^ o a m 0 I I gm � S 0 U Q U K Z M I i wwz � U $Z FQ- h J Q 2_ Kim U I I SHEET NAME: Lug t, SHEET d NUMBER: - ---------- -- --- ---- -- --� PV SYSTEM-SITE PLAN q SCALE: 1/16"= 1'-0" > d U N �rmE m vap mvz LPyO PV STRING k3. ROOF VENT(S Q c0i 18 MODULES � PLUMBING VENTS) ti COMP.SHINGLE Roof Section 2 Rod Azmlh:68 RodTL22 m —�/ O •� a •�TIE INTO METER 3884628 0 0 0 V a m Q K z W p K K N W W 2 m Roof Section 1 F Roof Azimuth:248 ,A m Roof Tilt:22 STRING VSTRING Y2. �_ z E p 17 MODULES 17 MODULES SHEET NAME: LLZ Of iZ SHEET NUMBER. PV SYSTEM ROOF PLAN 4 N SCALE: 3/32"= 1'-0" > ' a CLAMP MOUNTING SEALING U PV3.0 DETAIL WASHER LOWER 'Nmmm SUPPORT mz Oa-m PV MODULES, TYP. MOUNT "`"""" ''``' ' p N o OF COMP SHINGLE ROOF, FLASHING c � PARALLEL TO ROOF PLANE / 2 1/2 MIN = 5/16"0 x 4 112" L MINIMUM STAINLESS PV ARRAY TYP. ELEVATION STEEL LAG SCREW NOT TO SCALE TORQUE=13±2 fl-Ibs O CLAMP ATTACHMENT (/) NOT TO SCALE •e CLAMP+ ATTACHMENT CANTELEVER U4 OR LESS �G COUPLING j L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE w' MODULE CLAMP SPACING. g a PERMITTED COUPLING w gma CLAMP+ CLAMP CLAMP 0 ATTACHMENT SPACING w COUPLING PHOTOVOLTAIC MODULE > E a z u .. ww z m U 6 2_ 2_ min mt77 U H M SHEET NAME: L=PORTRAIT CLAMP SPACING EE Z J 7 Q O ECO Wp ' L=LANDSCAPE MODULEIBLE PV SYSTEM MOUNTING DETAIL SHEET NUMBER: CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 co NOT TO$CALE o_ DC Safety Switch Notes: Rated for max operating condition of inverter NEC 690.35 compliant *opens all ungrounded conductors U C Notes: SE1000OA-US-U Inverter Spec: -0 o" CEC Efficiency 97.50k (n- ALL CONDUCTORS tea= AC Operating Voltage 240V Continuous Max Output 42A 4�zz' SHALL BE COPPER DC Maximum Input Current 30.5A 'o C Solar Edge Optimizer Specs: P300 DC Input Power 30OW J DC Max Input Voltage 8-48V = ' Design COrldItI0f1S: DC Max Input Current 12.5A 9 DC Max Output Current 15A ASHRAE 2013 Max String Rating 525OW Highest Monthly 2%DB Design Temp 35.6°C. Module Specs: 50 PV MODULES PER INVERTER=13000 WATTS STC Lowest Min.Mean Extreme DB -17°C 1 STRING OF 17 PV MODULES VOC Temp coefficient V/°C Trina Solar TSM-260PDO5.08 O 1 STRING OF 17 PV MODULES SOI.AREDGE Short Circuit Current(Isc) 9.00A N N sE,OO Usu Open Circuit Voltage(Voc) 38.2V 1 STRING OF 16 PV MODULES INVERTER System Specs: Operating Current(Imp) 8.50A a Max DC Voltage 500V Operating Voltage(Vmp) 30.6V G 0 0 o G 7 ti DC�E:E Nominal DC Operating Voltage 350V Max Series Fuse Rating 15A SIMicH Max. DC Current per String 15A STC Rating(Pmax) 26OW 61 Nominal AC Current 47.5A Power Tolerance -0/+3% J Itm EXISTING souaeoGE _ _ SUPPLY-SIDE ""N ENTRANCE P300 OPTIMIZERS m SOLAR TAP CONDUCTORS 1 NEC 705.12(A) M RATED: 100A 5 g ML, —, S 4WFUEEDNRRfifl OPPOUVATNT O0.EDUIVAIENiSOLARE — VlelonMKW,m Q U PB000PTI.IZERS V0S35 N Q SHEET EXISTING NAME WERS 240V1125AAC w < LOAD-CENTERSRECANBIVISIBLE M a METER LOCKABLE KNIFE'ISCON.ECT .( SHSOLAREDNUMBERP3000PTM PV WIRE IN FREE AIR INTO THWNB IN 3/0"EMT O CONDUIT.KEEP UNDER Z%VOLTAGE DROP.MINIMUM 0 MINIMUM 6AWG CU WIRE(RATED IN 3/4'EMT O MINIMUM 6AWG CU WIRE iRATE0900fGQIN 3/WI .1OAWG CU WIRE EACH IflATE0900EG Q.6AWG BARE CONOUIi.POSITIVE,NEGATIVE;8 AWE G ROUND WIRE LONOUIT.LI,LZ,AND NEUTRALS AWG GROUND WI RE. COPPER EGO OR BAWG INSULATED DEC IN CON DUIT. KEEP UNDER 1.5%VOLTAGE DROP. KEEP UNDER I.5%VOLTAGE DROP. w mom . J (n Be m m c 0 1n zD N o OX n 0 m0 �o XZ mzCn N x (C/) A s D G) D mz 0 � m T1 m d - a 1 d -0 i0 0' O N Cm m, .0 Z mN KM INSTALLER'.VIVINTSOLAR ��a�� solar Hanford Residence 3m m DESIGN m m INSTALLER NUMBER:1.9]].4044129 43 Valle St PV 4.0 x LOGIC MA LICENSE:MAHIC I]0846 . Salem,MA 01970 DRAWN BY'RBR AR 441021 Last Motlified 6/1 912 0 1 5 UTILITY ACCOUNT NUMBER: 1330731006 EcolibriumSolar Customer Info Name: 4410203 Email: Phone: Project Info Identifier: 39199 Street Address Line 1: 43 Valley St Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model: TSM 260-PD05.08 Module Quantity: 50 Array Size (DC watts): 13000.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: SolarEdge Technologies Inverter Model: SE10000A-US (240V) Project Design Variables Module Weight: 43.0 Ibs Module Length: 65.0 in Module Width: 37.0 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load - Upward: 820 Ibf Lag Bolt Design Load - Lateral: 288 Ibf EcoX Design Load - Downward: 722 Ibf EcoX Design Load - Upward: 765 Ibf EcoX Design Load - Downslope: 297 Ibf EcoX Design Load - Lateral: 233 Ibf Module Design Moment— Upward: 3655 in-lb Module Design Moment— Downward: 3655 in-lb Effective Wind Area: 20 11:2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar Plane Calculations (ASCE 7-05): 1 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 15.0 ft Include Snow Guards: No Least Horizontal Dimension: 15.0 ft Roof Slope: 22.0 deg Truss Spacing: 24.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.88 0.88 0.88 Roof Snow Load 29.6 29.6 29.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.6 2.6 2.6 psf Snow Load 29.6 29.6 29.6 psf Downslope: Load Combination 3 11.2 11.2 11.2 psf Down: Load Combination 3 27.8 27.8 27.8 psf Down: Load Combination 5 12.4 12.4 12.4 psf Down: Load Combination 6a 29.0 29.0 29.0 psf Up: Load Combination 7 -14.6 -25.0 -38.2 psf Down Max 29.0 29.0 29.0 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 62.7 62.7 54.6 in Max Spacing Between Attachments With Rafter/Truss Spacing of 24.0 in 48.0 48.0 4&0 in Max Cantilever from Attachment to Perimeter of PV Array 20.9 20.9 18.2 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 47.3 47.3 41.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 24.0 in 24.0 24.0 24.0 in Max Cantilever from Attachment to Perimeter of PV Array 15.8 15.8 13.7 in EcolibriumSolar Layout Skirt e Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal O Clamp expansion and contraction. See Installation Guide for details. Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 28 Weight of Modules: 1204 Ibs Weight of Mounting System: 240 Ibs Total Plane Weight: 1444lbs Total Plane Array Area: 468 ft2 Distributed Weight: 3.09 psf Number of Attachments: 120 Weight per Attachment Point: 12 Ibs EcolibriumSolar Plane Calculations (ASCE 7-05): 2 Roof Shape: Gable Edge and Corner Dimension: 3.0 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 15.0 ft Include Snow Guards: No Least Horizontal Dimension: 15.0 ft Roof Slope: 22.0 deg Truss Spacing: 24.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.88 0.88 0.88 Roof Snow Load 29.6 29.6 29.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 10.0 10.0 10.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.6 2.6 2.6 psf Snow Load 29.6 29.6 29.6 psf Downslope: Load Combination 3 11.2 11.2 11.2 psf Down: Load Combination 3 27.8 27.8 27.8 psf Down: Load Combination 5 12.4 12.4 12.4 psf Down: Load Combination 6a 29.0 29.0 29.0 psf Up: Load Combination 7 -14.6 -25.0 -38.2 psf Down Max 1 29.0 29.0 29.0 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 62.7 62.7 54.6 in Max Spacing Between Attachments With Rafter/rruss Spacing of 24.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 20.9 20.9 18.2 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 47.3 47.3 41.2 in Max Spacing Between Attachments With Rafter/Truss Spacing of 24.0 in 24.0 24.0 24.0 in Max Cantilever from Attachment to Perimeter of PV Array 15.8 15.8 13.7 in EcolibriumSolar L_1yout Skirt e Coupling Note: If the total width of a continuous array exceeds 35 ft, break array to allow for thermal expansion and contraction. See Installation Guide for details. O Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with 0 Bonding Jumper maximum allowable overhang. EcolibriumSolar Roof Weights In Conformance with Solar ABC's Expedited Permit Process Module Quantity: 22 Weight of Modules: 946 Ibs Weight of Mounting System: 240 Ibs Total Plane Weight: 1186 Ibs Total Plane Array Area: 367 ft2 Distributed Weight: 3.23 psf Number of Attachments: 120 Weight per Attachment Point: 10 Ibs EcolibriumSolar Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 120 ECO-001_102 EcoX Coupling Assembly 76 ECO-001_1058 EcoX Landscape Skirt Kit 15 ECO-001 105A EcoX Portrait Skirt Kit 3 ECO-001_103 EcoX Composition Attachment Kit 120 ECO-001_116 EcoX Flat-Tile Flashing 0 ECO-001_117 EcoX S-Tile Flashing 0 ECO-001_118 EcoX W-Tile Flashing 0 ECO-001_363 EcoX Lower Support-Tile 0 ECO-001_109 EcoX Electrical Assembly (optional) 2 ECO-001_106 EcoX Bonding Jumper Assembly 9 ECO-001_104 EcoX Inverter Bracket Assembly 0 ECO-001 338 EcoX Connector Bracket 0 ECO_001-359 EcoX Lower Support- Low Slope 0