6 UGO RD - BUILDING INSPECTION
� O- 715—I t4 —I Z-(-lSs ;� The Commonwealth of Massachusetts Board of Building Regulations and Standards CITY OF Massachusetts State Building Code, 780 CMR SALEM Revised Mar 1011 Building Permit Application To Construct,Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Use Only ( Building Permit Number: Date A lied: W /u p UZ �— Building Official(Print Name) Signature SECTION 1:SITE INFORMATION LI Pr,open Address: 1.2 Assessors Map&Parcel Numbers la( nA 1.1 a Is this an accepted street?yes no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: _ Zoning District Proposed Use Lot Area(sq It) Frontage(a) y. 1.5 Building Setbacks(It) z c Front Yard Side Yards Rear Yard C p R Provided Required Provided Required Proi)—*d 3> equired Cn 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone information: 1.8 Sewage Disposal System• M ap Public❑ Private❑ Zone: Outside Flood Zone? Municipal❑ On site disposal s stem 13 Check if es❑ n SECTION 2: PROPERTY OWNERSHIP' r 2.1 Owner'of Record: Antonio Gonzales Salem, MA. 01970 Name(Print) City,State,ZIP 6 Ugo Rd 978-744-4486 Jiv_gonzales@yahoo.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK'(check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repairs(s) ❑ Alteration(s) ❑ 1 Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work: S(ABIA 5;14CMVv-) as •11 0 �rar�a IJ SS• s IM SECTION 4: ESTI ATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only (Labor and Materials) 1. Building $IbI'.W 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical gafj-'I�„Q ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire $ Suppression) Total All Fees: Check No. Check Amount: Cash Amount: 6.Total Project Cost: $ail?11"i S,oL> 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5.1 Construction Supervisor License(CSL) LO J GImks- SYI¢r�l P�Y� 1�25� P n e License Number Expiration Dale Name of CSL Holder ' " Vk _ MCk 'C/e- `A List CSL Type(see below) U No.and Street ` 1� Type Description Gj _ x� , r p U Unrestricted(Buildings u to 35,000 cu.ft.)_mod R Restricted 1&2 FamilyDwelling Cityflown,Stale, I/l/�✓ M Mason ry RC Roofing Covering WS Window and Siding _ c `,.1 SF Solid Fuel Burning Appliances nbl3DSWWS (�l(> so"etv@\1\VI>r14�\Ur<oq I Insulation Telephone Email address D Demolition 5.2 Registered Home Improvement Contractor(HIC) .J\\J \nt Scxat� \COSs�-1 HIC CoN me or,,��--III��C��R��e ts[an[Name HIC Registration Number Expiratioonn Date No.an tree[ \ U, y ,L,A x. Email address City/Town,State,ZIP L Telephone Y� SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152.§ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........❑ No...........❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property,hereby authorize y wy l t S6,Ck- to act on my behalf, in ve to work authorized by this building permit application. alt ers re fi �j - 11 /21/14 Print Owner's Name(Electronic Signature) Date SECTION 7b:OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and understanding.� l'..ty�-< �-=50 7 -Y� �I l Print Owner's or Authorized Agent' a(Elec nic Signature) Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G.L.c. I42A.Other important information on the HIC Program can be found at www.mass.eov/oca Information on the Construction Supervisor License can be found at wwwxr ass.eov/dns 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/attics,decks or porch) Gross living area(sq.ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substituted for"Total Project Cost" A CERTIFICATE OF LIABILITY INSURANCE DATE127tothe 1 013 7/2 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDCERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTREPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies) must be endorsed. If SUBROGATION IS WAIVED,the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rig certificate holder in lieu of such endoneement(s). PRODUCER CONTACT MARSH USA INC. NAME' 1225171H STREET,SUITE 1300 ac°RN Ert: NC No,. DENVER,CO 80202-5534 E-MAIL Attn:Denver.certrequest@marsh.cem,Fax:212.948,4381 ADDRESS: INSURERS AFFORDING COVERAGE NAIC d 462738-STND-GAWUE-14-15 INSURER A:Evanston Insurance Company 35378 INSURED YrvIOi Solar,Inc: INSURER B Zurich American Insurance Company 16535 Vivint Solar Developer LLC INSURER C:American Zurich Insurance Company 40142 3301 North Thanksgiving Way INSURER D: Suite 500 - Lehi,UT 84043 INSURER E NSURER F COVERAGES CERTIFICATE NUMBER: SEA-002368030-08 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR TYPE OF INSURANCE ADOL SUER POLICY NUMBER MMM LICY EFF MWDDII'1 YY LIMITS L R A GENERALLABILITY 14PKGWE00274 11/01/2014 11/01/2015 EACH OCCURRENCE $ 1,000,000 NIA CONT X COMMERCIAL GENERAL LIABILITY PREMISES EaEc rrence $ 501000 CLAIMS-MADE 1XI OCCUR MED UP(Any one person) $ 5,000 X $5,000 Ded.BI&PD PERSONAL BADV INJURY $ 1,000,000 GENERALAGGREGATE $ 2,000,000 . GEN'L AGGREGATE LIMIT APPLIES PER: PRODUCTS-COMP/OP AGG $ 2,OGD,000 POLICY X jpERCTF ILOC $ B AUTOMOBILE LIABILITY BAP509601500 11/01M14 11/01/2015 COMBINED SINGLE LIMIT 1000000 Ea acadent X ANY AUTO BODILY INJURY(Per person) $ ALL OWNED SCHEDULED BODILY INJURY(Per accident) $ AUTOS AUTOS X X NON-OWNED PROPERTY DAMAGE $ HIREDAUTOS AUTOS Peracadem A UMBRELLA IJAB X OCCUR 14EFXWE00088 . 11/01/2014 11/01/2015 EACH OCCURRENCE $ 5,000,000 X EXCESSLIAB CLAIMS-MADE AGGREGATE $ 5,000,000 DIED RETENTIONS I$ C WORKERS COMPENSATION WC509601300 11/01/2014 11/01/2015 X WCSTATU- OTH- AND EMPLOYERs'LIABILITY B ANY PROPRIETOR/PARTNER/EXECUTIVE YIN WC509601400 11/01/2014 11/01/2015 E.L.EACH ACCIDENT g 1,000,000 OFFICER/MEMBER EXCLUDED? NrA (Mandatary In NH) E.L.DISEASE-EA EMPLOYE $ 1,000,000 If ac..denbe under 1,000,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ A Enors&Omissions& 14PKGWE00274 11/01/2014 11/01/2015 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (Aaach ACORD 101,Additional Remarks Schedule,H mare apace Is required) The Gerflfcate Holder and others as defined in the written agreement are included as additional insured where required by written contract with respect to General Liability.This insurance is primary and non- contributory over any exisfing insurance end limited to liability arising out of the operators of the named insured and where required by written contract Waiver of subrdgafion is applicable where required by written contract with respect to General Liability and Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORQED REPRESENTAME. of Marsh USA Inc. Kathleen M.Pamloe ire-,e..71r. 44Z&i— ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 26(2010/05) The ACORD name and logo are registered marks of ACORD The Commonwealth of Massachusetts Department of Industrial Accidents GOffice of Investigations I Congress Street,Suite 100 -` Boston,MA 0211 4-2 01 7 ' www mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/ElectriciansMumbers Applicant Information Please Print Leeibly Name (Business/Organization/individual): Vivint Solar Developer, LLC Address:3301 North Thanksgiving Way,Suite 500 City/State/Zip:Lehi, UT 84043 Phone #:801-377-9111 Are you an employer? Check the appropriate box: Type of project(required): 1.0 1 am a employer with 10 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. ❑New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. Demolition working for me in any capacity. employees and have workers' [No workers' comp. insurance comp. insurance.t 9. El Building addition required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their I LE] Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no Solar Installation employees. [No workers' 13.❑ Other comp. insurance required.] 'Any applicant that checks box#1 most also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit anew affidavit indicating such. Tcontractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. lam an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Zurich American Insurance Company Policy#or Self-ins,��Lic. #:VIC/509601300 Expiration Date: 11/1/2I015 VL Job Site Address: U Jl J rd- City/State/Zip: S ,\� Q Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year 'imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under the pains and penalties ofperjury that the information provided above is true and correct. Sipnature: i Date Phone#: 801-2296459 Official use only. Do not write in this area,to be completed by city or town official. - City or Town: Permit/License # Issuing Authority(circle one): 1. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Office ofConsumer Affairs find Business Regulation 10 Park Plaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card.Mark reason for change. SCA i r, 2CM-05/11 Address ❑ Renewal Lj Employment Lost Card 1� Massachusetts -Department of Public Safety Board of Building Regulations and standards ConstructioSupenisor n License: CS-0452-045254 t JAMESRSHERMAN --" 6 Fox Hollow Drife SAUGUS MA 015M Expiration 08/28/20'16 Commissioner veV o tl Y o solar 3301 North Thanksgiving Way,Suite 500 Structural Group Lehi,UT84043 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scoff.wyssfingr?a vlvintsolar.com November 20,2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Gonzales Residence 6 Ugo Road, Salem MA S-4062767 5.355 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site VisitNerification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 6 dimensional lumber at 16" on center with 1 x 8 collar ties every 64". The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SEI 7-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 20 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per (ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. dabont. solar Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 40 PSF= Live Load (around snow load) • 5 PSF= Dead Load solar panels/mountina hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). If during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 1/2", is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 1/2" with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four (4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ver `r-ulyyours, �ytN0F .5Sy�yc� - P. CM y Scott E. Wyssl' PE ° 50 MA License N . 50 90 FGls r FFSSI ON A- vavunt. solar 6 Ugo Rd , Salem MA 01970 U C U � o (A o p 0 m (1) Ez mO (� U FROM JUNCTION BOX TO ELEC PANEL 2 O 5 PV SYSTEM SIZE: I ED TO 0 JUNCTION BO%ATTACH 5.355 kW DC ARRAY USING ECO HARDWARE TO KEEP JUNCTION BOX OFF ROOF I L_ M I I O V INTERCONNECTION POINT, I LOCKABLE DISCONNECT SWITCH, y ANSI METER LOCATION, y` &UTILITY METER LOCATION n I I wMI I a m m I a m m o 0 7 K m K U Q z m a � E az wm z NN � 3 (21)Yinali Enemy YL25SP-29h MODULES WITH A a Enphase M215E0-2LL-S2x-ZC MICRO-INVERTER ( SHEET MOUNTED ON THE BACK OF EACH MODULE I NAME: —————————————————————J ~ J d SHEET NUMBER: PV SYSTEM SITE PLAN SCALE: 3/32"= 1'-0" a N U C N "C 8 U) o� mw a)52 a o�z Roof Section 1 mz Roo(Azimuth:130 'o Roof Tilt 20 N C - TIE INTO METER O r OMP.SHINGLE HIMNEY 218B3168 '^ OOF VENT(S) V V1 N •C •G V ❑ ❑ e a gmoa uOi ¢ ' a PVCIRCUIT#2. ROOF VENTS V CIRCUIT#1: z m i 10 MODULES 11 MODULES > E mm PLUMBING VENTS m y J w w m Q3 V N y Q � z E O SHEET NAME: LL Z ofa SHEET NUMBER: PV SYSTEM ROOF PLAN o N SCALE: 3/16"= 1'-0" d CLAMP MOUNTING SEALING !- PV3.0 DETAIL WASHER 0 LOWER fn �¢ SUPPORT �m g' (n z mD PV MODULES, TYP. MOUNT "Q OF COMP SHINGLE ROOF, FLASHING C PARALLEL TO ROOF PLANE / 2 1/2" MIN 0 5 5/16"0 x 4 1/2" L MINIMUM STAINLESS (TS PV ARRAY TYP. ELEVATION STEEL LAG SCREW u NOT TO SCALE TORQUE=13t2 ft-Ibs O CLAMP ATTACHMENT V) NOT TO SCALE 0 •o ? CLAMP+ 8 ATTACHMENT CANTELEVER U4 OR LESS *© COUPLING J L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. o ;, � m N PERMITTED COUPLING c m g CLAMP+ CLAMP CLAMP o 7 ATTACHMENT SPAC NG i m = �d COUPLING PHOTOVOLTAIC MODULE a; � � m ww w m z 6 ? ? E O SHEET NAME: L=PORTRAIT W CLAMP SPACING F- zt7 Q O ECO 2 p COMPATIBLE SHEET L=LANDSCAPE MODULE PV SYSTEM MOUNTING DETAIL NUMBER: CLAMP SPACING (MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE a Inverter Ratings(Guide Section 4) hi Mamisheel sachems M21560.2LL52x-ZC O Conduit and Conductor Schedule MODULE DETAIL Max DC Vat Rating 45 Volk ran pevapem w,re Gage pW.1. tor Witsle Max Pi@4o-C 215 Walt I Fnpax a111.race-TnWN-] 12xWG cek wA-vreear U ^ Nominal AC Voltage 240 Vole t Bert cam,..(s...eco °PWG t WP-Free Nr WA-Fax Mr C O Yingli Energy YL255P-29b Max AC Cmmm 09 Amps 2 T"WN2 le.o s we a-r m SOLAR MODULE Max Oi KampKamp20 AmPe n Max Numcer of PaneNLimail 17 2 THWW2-anxi aAw6 I Ic .7 o ] TIWN1 a. g PVe V-1' NOTES FOR INVERTER CIRCUITS(Guide Section 8 and 9), s THWll (ae.e I Pvc a-,- i mW om 1.)IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH,DOES THIS IY¢, PV Module Ratings @STC(Guide Section 5) p z EOphase M215.60-2LLS2x-ZC SWITCH MEET THE REQUIREMENTS? 72 Z MICRO-INVERTER AT YES NO XNA Model MakelMotlel Yingli Energy YL255P-29b tn.mj EACH MODULE,ATTACHED Max Power-Point Conant(imp) 8.32 Amps A� 2.)IF GENERATION METER REQUIRED,DOES THIS METER Max Power-Point Voltage(Vmp) 30.6 Volta �✓ WITH ECO HARDWARE SOCKET MEET THE REQUIREMENTS? Open-Ciwit Voitage(Voq 31 Volts � �O YES NO XNA Shod-Circuit Current(Isc) 8.88 Amps N >Q> 3.)SIZE PHOTOVOLTAIC POWER SOURCE DC)CONDUCTORS Max Series Fuse(OCPO) 15 Ampa C F BASED ON MAX CURRENT ON NEC 690.53 SIGN OR OCPD Nominal Maximum Power at STC IPmax) 1 255 Walls MICROI INVERTER CON NECTION _ RATING AT DISCONNECT. Maximum Sloop.Voltage loeo(IEE7y6 (Uy O D TO ENGAGE TRUNK CABLE 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING one Temperature Coefficient ^ TO INVERTER OCPD AMPERE RATING(See Guide Section 9). V 5.)TOTALOF ] INVERTER OCPD(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING(Guide Section 6 and 8 and Appendix Du PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY ,, WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean extreme p6 BARE CU GROUND NECE90.134(8)(2)(e)? XYES NO dry bulb temperature for ASHRAE location most similar to installaton location: -19-C (GROUNDING ARRAY) Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%dry bulb temperature for ASHRAE location most similar to installation location: 39-C Sign for inverter OCPD and AC Disconnect: 3.)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47°0 in the 0 United States(Palm Springs,CA is 44 A'C).For less than 9 cunent,carrong conductors Solar PV System AC Point of Connection in roofanounted sunlit conduit at least 0.5'above mot and using the outdoor design AC Output Cunent 18900000 Amps temperature of 47'C or less(all of United States). o Nominal AC VO4890 2411 Volts or less AWG,prof companies by a rs are generally acceptable for modules with Isc IN 7.68 Amps or less Wnen protected by a 12-Amp or smaller fuse. 'V THIS PANEL FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) or)less AWG,prof conductors by a I are generally acceptable for modules wlth Isc of 9.6 Amps or less when protected b e 1SAm or smaller fuse. NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY •� ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR Mo �J PV CIRCUIT 1: 11 MODULES/PARALLEL ENVOY BOX S. mse ^ a g be e [to tore KT Z rea be E 1.0 MURRAY POINT OF DELIVERY ' 0 m COMBINER AND INTERCONNECTION w w z m \y0�0EL 125A/240V SIEMENS a a W 3 \G GLWO04NR 60A1240V l- I- - \tc<`20 EQUIVALENT UNFUSED NEMA3 M Z Z"T\� <[<` 1 SREC/ANSI LNF222R OR SHEET PV CIRCUIT 2: 10 MODULES/PARALLEL EQUIVALENT Oq\6,p METER NAME: \O EXISTING zoo 240V1200A LU 1 I \ lsA LOAD-CENTER Z ✓` • • • J. f E 1.0 I \\ 30A SHEET O 4 NUMBER: \\ MILBANK VISIBLE/LOCKABLE 4— JUNCTION BOX 2 \\ 3 100A OR 3 'KNIFE'A/C 3 O WITH IRREVERSIBLE \ EQUIVALENT DISCONNECT NEC 2014 Compliant GROUND SPLICE E 1.0 \ E 1.0 U5934-XL-BLG E 1.0 E 1.0 LU Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Jeaneath Gonzales Project Address: 6 UGO RD,SALEM MA A. System Description: The array consists of a 5.355 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(21) 255-watt modules and (21) 215-watt micro-inverters,mounted on the back of each PV module.The array includes (2) PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecolibrium Solar, B.Site Design Temperature: (From Boston Logan INT'L ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C. Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2. Structural Review of PV Array Mounting System: A.System Description: 1. Roof type: EcoX Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing B. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2. For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecolibrium Solar b.Product Name: Ecorall c.Total Weight of PV Modules and mounting hardware: 884.2 Ibs d.Total number of attachment points: 70 e.Weight per attachment point: 12.63 Ibs f.Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 369.26 square feet It. Array pounds per square foot 2.39 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (21)modules,(70)attachments 12.63 pounds vivint. solar 3. Electrical Components: A. Module (UL 1703 Listed) Qty Yingh Energy YL255P-29b 21 modules Module Specs Pmax-nominal maximum power at STC - 255 watts Vmp-rated voltage at maximum power - 30 volts Voc-rated open-circuit voltage - 37.7 volts Imp-rated current at maximum power - 8.49 amps Ise-rate short circuit current - 9.01 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-21 J S22 21 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max. start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max. units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 11 modules/inverters (15) amp breaker PV circuit 2 - 10 modules/inverters (15) amp breaker 2011 NEC Article 705.60(B) vivint. soIar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 9.9 amps Continuous current adjustment factor 125% 2011 NEC Arricle 705.60(B) PV circuit continuous current rating 12.375 amps 2.Overcurrent protection device rating PV circuit continuous current rating 12.375 amps Next standard size fuse/breaker to protect conductors 15 amp breaker . Use 15 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC Article 705.60(B) Adjusted maximum ambient temperature 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 60.4°C (140.72°F) 71% 2011 NEC Arrtkk 705.60(B) Adjusted PV circuit continuous current 17.4 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill Berate factor 80% 2011 NEC Arricle 705.60(B) Final Adjusted PV circuit continuous current 13.9 amps Total derated ampacity for PV circuit 13.9 amps Conductors (tag2 on 1-line)must be rated for a minimum of 13.9 amps THWN-2(90°C) #14AWG conductor is rated for 25 amps (Use#14AWG or larger) 2011 NEC Article 705.60(B) 4.Voltage drop (keep below 3%total) 2 parts: 1.Voltage drop across longest PV circuit micro-inverters (from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1,Mirco-inverter voltage drop: 0.18% The largest number of micro-inverters in a row in the entire array is 6 inCircuit 1.According to manufacturer's specifications this equals a voltage drop of 0.18%. 2.AC conductor voltage drop: =I x R x D (=240 x 100 to convert to percent) _ (Nominal current of largest circuit)x (Resistance of#14AWG copper)x(Total wire run) _ (Circuit 1 nominal current is 9.9 amps) x(0.0031952)x(130) _(240 volts)x(100) 1.71% Total system voltage drop: 1.89% v®vint. solar EcolibriumSolar Customer Info Name: Email: Phone: Project Info Identifier: 16171 Street Address Line 1: 6 Ugo Rd Street Address Line 2: City: Salem State: MA Zip: 01970 Country: United States System Info Module Manufacturer: Yingli Solar Module Model: YL255P-29b Module Quantity: 21 Array Size (DC watts): 5355.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 40.8 Ibs Module Length: 65.0 in Module Width: 39.0 in Basic Wind Speed: 100.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: 11 Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Wind Directionality Factor: 0.85 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load- Upward: 820 Ibf Lag Bolt Design Load- Lateral: 288 Ibf EcoX Design Load - Downward: 493 Ibf EcoX Design Load - Upward: 568 Ibf EcoX Design Load - Downslope: 353 Ibf EcoX Design Load - Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 EcolibriumSolar .20 Plane Calculations (ASCE 7-05): 1 Roof Shape: Gable Edge and Corner Dimension: 3.2 ft Roof Type: Composition Shingle Stagger Attachments: No Average Roof Height: 25.0 ft Include Snow Guards: No Least Horizontal Dimension: 32.0 ft Roof Slope: 20.0 deg Truss Spacing: 16.0 in Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.91 0.91 0.91 Roof Snow Load 30.6 30.6 30.6 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Net Design Wind Pressure Downforce 9.4 9.4 9.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -16.0 -26.4 -39.6 psf Design Wind Pressure Downforce 16.0 16.0 16.0 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 30.6 30.6 30.6 psf Downslope: Load Combination 3 10.6 10.6 10.6 psf Down: Load Combination 3 29.2 29.2 29.2 psf Down: Load Combination 5 18.2 18.2 18.2 - psf Down: Load Combination 6a 34.4 34.4 34.4 psf Up: Load Combination 7 -14.7 -25.1 -38.3 psf Down Max 34.4 34.4 34.4 psi Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 52.9 52.9 52.9 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 48.0 48.0 48.0 in Max Cantilever from Attachment to Perimeter of PV Array 17.6 17.6 17.6 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 31.7 31.7 31.7 in Max Spacing Between Attachments With Rafter/Truss Spacing of 16.0 in 16.0 16.0 16.0 in Max Cantilever from Attachment to Perimeter of PV Array 10.6 10.6 10.6 in EcolibriumSolar Layout Skirt e Coupling o Clamp Warning: PV Modules may need to be shifted with respect to roof trusses to comply with ® Bonding Jumper maximum allowable overhang. EcolibriumSolar Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 857 Ibs Weight of Mounting System: 140 Ibs Total System Weight: 997 Ibs Total Array Area: 370 ft2 Distributed Weight: 2.7 psf Number of Attachments: 70 Weight per Attachment Point: 14 Ibs Bill Of Materials Part Name Quantity ECO-001_101 EcoX Clamp Assembly 70 ECO-001_102 EcoX Coupling Assembly 31 ECO-001_105B EcoX Landscape Skirt Kit 7 ECO-001 105A EcoX Portrait Skirt Kit 1 ECO-001_103 EcoX Composition Attachment Kit 70 ECO-001_109 EcoX Electrical Assembly 1 ECO-001_106 EcoX Bonding Jumper Assembly 5 ECO-001_104 EcoX Inverter Bracket Assembly 21 ECO-001 338 EcoX Connector Bracket 21