Loading...
18 SAUNDERS ST - BPA 15-1162 7�/�� t,K S Zs1 . 1 RECEIVED The Commonwealth of Massachusetts 1 u i E R V I C E S Board of Building Regulations and Standards CITY OF Massachusetts State Building Code,780 CMR Idil�Sel r4'011 ( 9 a Building Permit Application To Construct,Repair,Renovate Or I lemolish a �C One-or Two-Family Dwelling This Section For Official se Only ( Building Permit Number: Date*lied: —� Building Official(Prim Name) - Signature Vate SECTION 1:SITE INFORMATION Pro rty Addreea: 1.2 Assessors Map&P eel Numbers L! 187Saunders Street 1 LL la Is this an accepted street?yes_ no Map Numb Parcel Number I` 13 Zoning Information: 1A Property Dimension : Zoning District Proposed Use Lot Area(sq 11) Frontage(R) 1.5 Building Setbacks 00 Front Yard Side Yards i Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone? Muti(ipal❑ On site disposal system O Check if yeaO SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Sumathi Athuluri Salem MA 01970 Name(Print) City,State,ZIP 18 Saunders Street 978=908-0001 No.and Street - Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORIO(cheek all that apply)- New Construction❑ Existing Building 12 Owner-Occupied ❑ 1 Repans(s) ❑ 11 Altetation(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units Other 6d pecify: Solar Brief Description of Proposed Wore: 1 Installation of a 7.25 kw(29 panels) rooftop solar array I I SECTION 4:ESTIMATED CONSTRUCTION CO TS Item Estimated Costs: I OtHeial Use Only (Labor and Materials 1.Building $ 12 000 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ 23,127 ❑Standard City/Town Applica ion Fee ❑Total Project Cost'(Item 6)x�multiplier x 3.Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire Suppression) $ Total All Fees:$ I - Check No.I Check Amo t: Cash Amount:_ 6.Total Project Cost: $ 35,127 . O Paid in Full O Cum inding Balance Due: rVlla���� t" slag,=. loln i i SECTION 5: CONSTRUCTION SERVICES , 5.1 Construction Supervisor License(CSL) 096385t(s,,bl,.) 10/8/2016 Romain Strecker License NumExpiration Date Namc of CSL Holder - j J List CSL 55 Sixth Rnad Type Description No.and Street U Unreshicted(Buildings to 35.000 cu.ft.) Woburn MA 01801 R Restr red lee F Dwe " City/Town,State,ZIP M Maso RC Roos Coverio WS Wind w and Siding SF Solid Fuel Burning Appliances 781-462-8702 _permitsobostonsolanus I bs"htim Telephone Email address D Demdlitim 5.2 Registered Home Improvement Contractor(HIC) 169 98 7/27/2017 Boston Solar/Romain Strecker HIC—Reg tmtionNumber Expiration Date HIC Name INC Registrant Name 555 SLxt�i Roaa perinitspbostonsolar.us No.and 3trat 781-462-8702 Email address Woburn MA 01801 Ci /Town State ZIP Tel hone F SECTION 6:WORKERS'COMPENSATION INSURANCE AFFMA (M.G.L.e.152.$ 25C(6)); Workers Compensation Insurance affidavit must be completed and submitted with d is application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit Signed Affidavit Attached? Yes..........® No...........0 111 SECTION 7s:OWNER AUTHORIZATION TO BE COMP TED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUD DING PERMIT L as Owner of the subject property,hereby authorize Romain Strecker to act on my behalf,in all matters relative to work authorized by this building peffm application. Sumathi Athuluri 10/20/2015 Print Owner's Name(Electronic Signature) I IDace SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true and accurate to the best of my knowledge and orderstanding. Romain Strecker 10/20/2015 Print Owner's or Authorved Agent's Name(Electronic Signatem) Date NOTES: 1. An Owner who obtains a building permit to do his/her own work,or an owner i iho hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program),will not{lave access to the arbitration program or guaranty fund under M.G.L.c.142A.Other important information n the HIC Program can be found at www.mass.eov/oca Information on the Construction Supervisor License can belfound at www.njKs aov/dos t 2. When substantial work is planned,provide the information below: - - - Total floor area(sq.R) (including garage,finished;asement/attics,decks or porch) Gross living area(sq.ft.) Habitable room oust _ Number of fireplaces - Number of bedr wDO r Number of bathrooms Number of half/paths Type of heating system Number of deeps/porches Type of cooling system Enclosed Open 3. `Total Project Square Footage"may be substituted for'Total Project Cost" I a CITY OF SALEh1, �LkSSACHUSEM BUHMING DEP kRTsw.%-r 130 W.iSH1Ne;,TON S ,3 F[.00R TEi.(978)145 9595 FAX(97>I)74 48" 103,IB UEY DRWOLL T MAYOR ttol►us ST. DIRECTOR OF PLBLIC PROPERLY IDUUMING CONISQSSIONER Construction Debris Disposal Affidavit (required for all demolition and renovat on work) In accordance with the sixth edition of the State Building Cc de.780 CUR section 111.5 Debris,and the provisions of MGL c 40,S 54; Building Permit# is issued with the condii ion that the debris resulting from this work shall be disposed of in a properly licensed waste disposal facility as defined by MGL c 111,S 150A. The debris will be transported by: Boston Solar (name of hauler) The debris will be disposed of in : Roston Solar ' (name of facility) 55 Sixth Road Woburn MA (address of facility) Signature of p rmit applicant 10/20 2015 hate dcbrisull:doe _ - OB ce of Co".."Affairs&Business Regulation License or registration valid for individul use only 410ME IMPROVEMENT CONTRACTOR before the expiration data If found return to: g— egistration: 169698 Type: Office of Consumer Affairs and Business Regulation WExpiration: 7/27Y2017 LLC 10 Park Plaza-Suite 5170 s .; Boston.MA 02116 THE BOSTON SOLAR COMPANY LLC ROMAIN STRECKER 3 ' 10 CHURCHILL PLACE LYNN,MA 01902 Undersecretary Not valid without signature s t Massachusetts Department of Public Safety Board of Building Regulations and Standards CoBctruction Supenicor License: CS-096385 ROMAIN D STRE.MER f 10 CHIJRCHQ L KAr, LYNN MA 0190f , Expiration Commissioner 10/08/2016 '\ The Commonwealth of Massachusetts Department of Industrial Accidents I Congress Street,Suite 100 Boston,MA 02114-2017 www.mass.gov/dia Wivorkers'Compensation Insurance Affidavit:Builders/ContractorstElectricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name(Business/Organiration/Individua4:The Boston Solar Company Address:55 Sixth Road City/State/Zip:Woburn MA 01801 Phone#:617-858-1645 Are you an employer?Check the appropriate box: Type of project(required): LE]1 am a employer with 20 employees(full and/or part-time).- 7. ❑New construction 2.❑1 am a sole proprietor or partnership and have no employees working for me in 8. ❑Remodeling any capacity.(No workers'comp.insurance required.) 9. El Demolition 3.[][am a homeowner doing all work myself.[No workers'comp.insurance required.]! 10❑Building addition 4.01 ern a homeowner and will be hiring contractors to conduct all work an my property. 1 will ensure that all contractors either have workers'compensation insurance or are sole 1 I.❑Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5. 1 am a general contractor and 1 have hired the sub-contractors listed on the attached sheet. ❑ 1 .❑Roof repairs These sub-contractors have employees and have workers'comp.insurances 14.❑I Other solar 6.❑We are a corporation and its officers have exercised their right of exemption per MGL c. 152,§I(4),and we have no employees.(No workers'comp.insurance required.] Any applicant that checks box kl must also fill out the section below showing their workers'compensation policy information. +Homeowners who submit this affidavit indicating they are doing all work and then hive outside contractors must submit a new affidavit indicating such. 'Contractors that check this box must attached an additional sheet showing the name of the sub<orr actors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I ant an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:HDI-Gerling America Insurance Company Policy#or Self-ins.Lic.#:EWGCC000153815 Expiration Date:1/14/2016 Job Site Address: 18 Saunders Street City/State/Zip: Salem MA 01970 Attach a copy of the workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. .917 I do hereby certify under the pain n hies ofperjury that the information provided above is true and correct Signature, Date: 10/20/2015 i Phone 4.617-858-1645 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.CitylTown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: THE BOSTON SOLAR Solar System Purchase and Installation Agreement Overview Installer Owner The Boston Solar Company,LLC Sumathi Athulun 55 Sixth Rd 18 Saunders St. Woburn,MA 01801 Salem,MA 01970 Major Components System Size: SPWR-250 29 7.3 kW Inverter SunPower Estimated Year l Production Production Monitoring Automated 8,939 kWh Total System Cost $35,226.25 Payment Schedule Federal Tax Credit' $10,537.88 At Signing $10,537.88 State Tax Credit' $1,000.00 At Installation $21,075.75 MASolar or Utility Rebate' $4,200.00 At System Commissioning $3,512.63 Final System Cost $19,388.38 Total of Payments $35,126.25 Payment Type Loan 'These financial estimates are provided for illustrative purposes. For actual financial and tax advice,please consult an independent tax advisor. Overview. As part of this Agreement,The Boston Solar Company will: • Handle all aspects of the project from initial paperwork through to installation and activation of your Solar System • Secure State or Utility rebates(if applicable),permits,and utility interconnection approval • Install revenue grade monitoring,giving you real time insight into your system's performance,and allowing you enjoy automatic production reporting to generate your SRECs(Owner is required to have secure and stableinternet connection on the Property) • Handle SPEC aggregation and sell your SRECs quarterly on your behalf(starting approximately six months after your system is activated) • Provide you with all related manufacturer warranties Timefor Completion: The Work to be performed by Contractor pursuant to this Agreement,starting with preparation and submission of a full permitting package, shall be commenced within 30 days of contract signing. It is expected that installation should start within 60-90 days after contract signing. The actual Installation is expected to take 2-3 days.Once installation is completed,the Owner will need to make the Property available for electrical and building inspections within two weeks after installation.After inspections,the utility is expected to give us final approval to turn on the system within 2-4 weeks. The entire process from contract signing to system commissioning is expected to take 3-4 months,but may take longer depending on town and utility approvals,weather and equipment availability. Additional Contract Provisions: All payments are due immediately upon completion of each stage of the project.quoted system price includes permit costs and utility interconnection fees. This Solar System includes a 10-year labor warranty,25-year Inverterwarranty and 25-year panel power warranty. Agreement: This Attachment forms part of the Solar Purchase and Installation Agreement. Boston Solar Representative Signature: FF(( �•1 1 - - Date: Owner's Signature: C _ If�/� 1 �1�/ Date: Signature Certificate RightSipature n Document Reference: LAWNK212VJ33UHS5DRXZ6F Easy Online Document Signing t Sumathi Athuluri Elactal5y ¢tore. Party DLIKLA1664T9KF3J5FHCD4 IP Address:41.206.1.3 ' vsalrlso emal�: jkmakam@me.com Digital c12c2e95242360d13ae4f3b5e34996e833991500 FIBROMA! YAA'llll 1 Digital Fingerprint Checksum 1'NYIR'iL I■Y �{'i�11�5HYr I Timestamp Audit 2015-10-08 21:59:26-0700 All parties have signed document.Signed copies sent to:Sumathi Athuluri and j Michael Lazzaro. 2015-10-08 21:59:26-0700 Document signed by Sumathi Athuluri akmakam@me.com)with drawn signature.- r 105.112.18.232 ! 2015-10-08 21:54:28-0700 Document viewed by Sumathi Athuluri Qkmakam@me.com).-41.206.1.3 2015-10-07 09:41:45-0700 Document created b Michael La=o michael.lazzaro bostonsolar.us .- Y I @ ) 50.169.65.188 I a � } A i I 1 i J i 1 1 0 Ok�AI This signature page provides a record of the online activity executing this contract. Page 1 of 1 BOSTON SOLAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT D�wne1 Sumathi Athuluri (the "owner") �site A�dqe s, 18 Saunders St. Salem, MA 01970 .._,�, (the "Property") =Date3 07/09/2015 This Solar System Purchase and Installation Agreement("Agreement") is entered into effect as of the latest date of signature of the parties below by and between The Boston Solar Company LLC, 55 Sixth Rd, Woburn,MA 01801("TBSC") and the Owner, who is the owner of the Property.All capitalized terms used in this Agreement but not defined herein shall have the meanings set forth in The Boston Solar Company Proposal attached hereto(the "Attachment"). 1. THE WORK TBSC shall perform work,provide the Services,supply such Equipment and furnish such other materials, supplies and other items as it determines are required to install the System described in the Attachment(the "Work").TBSC will perform or cause its subcontractors to perform the Work in a good and workmanlike manner,in accordance with prudent industry standards and practices.TBSC shall not make any changes in the Work unless agreed to in writing by the Owner. 2. REQUIRED PERMITS TBSC shall be responsible for acting as the Owners agent to secure any permits required for the installation. All permit costs are included in the price for the Work.If you secure your own permits,you will be excluded from the Guaranty Fund provisions of Chapter 142A of the Massachusetts General Laws. 3. WARRANTIES TBSC warrants that,under normal use and service conditions,the System will be free from defects in workmanship and/or materials for ten(10)years after the date of the Work being completed(this"Limited Warranty").This Limited Warranty includes servicing manufacturer warranties free of charge.TBSC warrants any damage to Owner's roof within a five(5)inch radius of roof penetrations during performance of the Work. If a defect is discovered,TBSC will,at no additional cost to Owner,provide such labor and materials as required to restore the System to its originally installed state. If TBSC finds that the problems were not caused by the Work,or if the problems are not an actual problem of the System(e.g.shade or unauthorized alterations to the System),Owner will pay for any new parts and materials,and TBSC reserves the right to charge Owner a service charge of$100 per hour with the minimum service charge equal to$200. 1 BOSTON SOLAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT Effective immediately upon Owner making the final payment under this Agreement,TBSC hereby assigns to Owner,to the extent assignable,any and all manufacturer warranties covering the Equipment and shall deliver copies of such warranties after its receipt of such final payment. 4. TIME FOR PERFORMANCE TBSC shall perform the Work diligently,without unnecessary delays or interruptions and in a timely manner until completed.TBSC shall use reasonable efforts to start and complete the Work according to the timing described in the Attachment. 5. INSURANCE AND LICENSING TBSC represents and warrants to the Owner that TBSC or any subcontractors performing the Work shall be licensed and hold insurance coverage as required by applicable laws. TBSC is registered as a Home Improvement Contractor with the Massachusetts Office of Consumer Affairs and Business Regulation, under registration#169698. 6. OWNER CANCELLATION RIGHTS If Owner delivers a completed Notice of Cancellation within three(3)business days after the date of this Agreement,TBSC shall refund and return the Deposit in full to the Owner within ten(10)business days after its receipt of such Notice of Cancellation(attach to this Agreement). Owner acknowledges that TBSC will spend time and money evaluating the Property,designing the System and preparing the Work.If Owner cancels this Agreement after ten(10)business days,a cancellation fee of $1,000 will be deducted from the Deposit.Any permit costs and unrecoverable equipment costs incurred by TBSC will be added to the cancellation fee and deducted from the Deposit. 7. TAX CREDITS, REBATES AND SRECS The Owner may be entitled to certain financial benefits related to the ownership and use of the System, including state or utility rebates("Rebates"),solar renewable energy certificates("SRECs"),state and federal income tax credits and net metering credits("Net Metering")(collectively defined as"Benefits").TBSC shall prepare, process and submit applications on behalf of Owner for Rebates,SRECs and Net Metering.TBSC is acting purely as an administrative agent and cannot guarantee the outcome of such applications. The Attachment includes an estimate of the Benefits that may be available to the Owner.TBSC makes no representation or warranty with respect to the Owner's eligibility to receive such Benefits. In all cases,Owner agrees to consult with the relevant governmental officials and Owner's accountant when evaluating Owner's eligibility for and the financial and tax consequences of receiving Benefits. 2 { BOSTON SOAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT 8. PRE-EXISTING CONDITIONS AND PROPERTY PROTECTION TBSC shall not be responsible for any damages as a consequence of the Work performed on the site due to pre-existing conditions(e.g.cracked or broken shingles,faulty electrical wiring,etc.) TBSC reserves the right to suspend performance of the Work or terminate this Agreement with no liability to TBSC whatsoever if it discovers unanticipated site conditions that will increase the cost to perform the Work. If such termination occurs,TBSC shall refund all monies paid to TBSC reduced by any expenses actually incurred.However, if Owner and TBSC agree,the price may be renegotiated to reflect the true cost of the Work. TBSC will make best efforts to protect any property of the Owner,but the Owner is responsible for removing and replacing appliances,floor coverings,and any other obstacles or hazards required to perform the Installation.TBSC is not responsible for replacement of or damage to these items if they are removed by TBSC. 9. CUSTOMER OBLIGATIONS Owner agrees to:(a)notify TBSC immediately upon discovery of an emergency condition relating to the System,damage to the System,or theft of the System;(b)only have the System repaired pursuant to the Limited Warranty(as defined herein);(d)not modify the Property in a way that shades the System;(e)not do anything,permit or allow to exist any condition or circumstance at the Property which would cause the System not to operate as intended;and(g)permit TBSC,after providing reasonable notice,to inspect the System for proper operation,and to make any necessary repairs.Customer agrees to not make any modifications,improvements,revisions or additions to the System or take any other action that could void the Limited Warranty(as defined herein)without TBSCs prior written consent.If Owner fails to comply with the provisions of this paragraph,Owner's Limited Warranty shall be automatically voided. 10. GENERAL PROVISIONS - Any disputes which may arise between the Owner and TBSC shall not impede or interfere with the diligent performance by TBSC of the Work.This Agreement shall be subject to and interpreted in accordance with the laws of the State of Massachusetts. Title,ownership and risk of loss to the System shall pass to Owner immediately upon Owner's payment of the final payment required under this Agreement.Owner shall provide all insurance necessary for the coverage of the System and risks to the Property related thereto after such payment. 3 f: BOSTON SOLAR SOLAR SYSTEM PURCHASE AND INSTALLATION AGREEMENT This Agreement,including the documents incorporated into this Agreement,forms the complete integrated agreement between TBSC and the Owner.The parties represent and warrant that in executing this Agreement,they are not relying on representations other than as expressly contained herein.There are no other terms or conditions that form a binding agreement between the parties other than this Agreement and its incorporated documents.This Agreement supersedes all prior agreements between the Owner and TBSC and may not be altered absent a subsequent written agreement signed by both parties.Both parties have reviewed this Agreement and represent that they understand and agree to the terms herein. ;Own��er� s Signature; Co-Owner's Signature: O er's Name: Sumathi Athuluri Co-Owner's Name: iDate:: 7/na/2.ni s Date: tTBSC Authorized Representative Signature: �.L 2 iiil B SC Authorized Representative a Michael Lazzaro Date: 7/1/201 4 0- 11 BOSTON SOLAR Homeowner's Agent Authorization Form 1, Sumathi Athuluri (Prnt.Name). am the owner of the property located at address: 18 Saunders St. Salem, MA 01970 CPrint Address) I herebyauthorized The Boston Solar Company to act a p y s my Agent for the limited purpose of applying for obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. Print Name:; Sumathi Athuluri l (Customer Signatu e Date 07/09/2015 The Boston Solar Company 55 Sixth Road Woburn,MA 01801 BostonSolar.us (617)858-1645 S EAH Structural Consulting 11 Ponvhronk Lane Lexington, MA 02421 PHONE 1.978.406.8921 9A COW]9u LING .Elaine@EAHstructural.com October 15, 2015 To: Boston Solar 55 Sixth Road Woburn, MA 01801 Subject: Structural Certification for Installation of Solar Panels Athuluri Residence - 18 Saunders Street Salem, MA.01970 To Whom It May Concern, A design check for the subject residence was done on the existing roofing and framing systems for the installation of solar panels over the roof. From a field inspection of the property,the existing roof support structures were observed by the client's auditors as follows: The roof structure of(MP1)consists of composition shingle on roof plywood that is supported by nominal 2x10 rafters @ 16"o.c., paired with nominal 2x10 ceiling joists @ 16"o.c..The rafters have a max projected horizontal span of 13'-0", with a slope of 36 degrees.The rafters are connected at the ridge to a continuous double 2x12 ridge board and are supported at the eave by a load bearing wall. There are 2x8 collar ties @ 16"o.c.for structural stability.. The existing roof framing system of(MP1) is judged to be adequate to withstand the loading imposed by the installation of the solar panels. No reinforcement is necessary. The spacing of the solar standoffs should be kept at 48"o.c.with a staggered pattern to ensure proper distribution of loads. I further certify that all applicable loads required by the codes and design criteria listed below were applied to the Invisimount solar rail system and analyzed. Furthermore,the installation crews have been thoroughly trained to install the solar panels based on the specific roof installation instructions developed by Invisimount for the racking system and Sunmodo for the roof connections. Finally, I accept the certifications indicated by the solar panel manufacturer for the ability of the panels to withstand high wind and snow loads. Design Criteria: • Applicable Codes=Massachusetts Residential Code,8th Edition,ASCE 7-05,and 2005 NDS • Roof Dead Load=9 psf(MP1) • Roof Live Load=20 psf • Wind Speed=100 mph, Exposure C • Ground Snow Load =40 psf - Roof Snow Load =28 psf Please contact me with any further questions or concerns regarding this project. Sincerely, l rya TH OF Q4,p`r0[, 2� EtAINE A. yew o HUANG CIVIL �+ Elaine Huang,P.E. q N0.4929 Project Engineer S/ONAL EHG i Athuluti Residence, Salem 1 EAH Structural Consulting 11 P, . Lane Lexingtonton,, M h1A 02421 PHONE 1.978.406.6921 EA CE H Cil]N{dU LTINGt ElainegEAHstructu-al.com Gravity Loading F Rrof Snow Load Calculations p9=Ground Snow Load= 40 psf pf=0.7 Ca CI I p9 (ASCE7-Eq 7-1) CQ=Exposure Factor= 1 (ASCE7-Table 7-2) CI=Thermal Factor= 1 (ASCE7-Table 7-3) 1=Importance Factor= 1 pf=Flat Roof Snow Load= 28.0 psf ps=Cspf (ASCE7-Eq 7-2) Cs=Slope Factor= 1 ps=Sloped Roof Snow Load= 28.0 psf PV Dead Load=4 psf(Per Boston Solar Roof Dead Load(MP1) Composition Shingle 4.00 Roof Plywood 2.00 2x10 Rafters @ 16"o.c. 2.90 Vaulted Ceiling 0.00 (Ceiling Not Vaulted) Miscellaneous 0.10 Total Roof DL(MP1) 9.0 psf DL Adjusted to 36 Degree Slope 11.1 psf Athuluti Residence, Salem 2 EAH Structural Consulting it E.�Lane Lexington, MA 02421 .PHONE 1.978.406.8921 EA M CON3uLTINC Elaine CaEAHstructu ral.com Wind Calulations Per ASCE 7-05 Components and Cladding `Input Variables!'�} Wind Speed 100 mph Exposure Category C Roof Shape Gable/Hip Roof Slope 36 degrees Mean Roof Height 20 ft Building Least Width 40 ft Effective Wind Area 17.5 ft ` Design Wind Pressure Calculations I Wind Pressure P=gh'(G'Cp) qh=0.00256'Kz"Kzt'Kd'V^2'I (Eq_6-15) Kz(Exposure Coefficient)= 0.9 (Table 6-3) Kzt(topographic factor)= 1 (Fig.6-4) Kd(Wind Directionality Factor)= 0.85 (Table 6-4) V(Design Wind Speed)= 100 mph I Importance Factor= 1 (Table 6-1) qh= 19.58 r Standoff Uplift Calculations' ) Zone 1 Zone 2 Zone 3 Positive GCp= -0.90 -1.10 -1.10 0.85 (Fig.6-11) Uplift Pressure= -17.63 psf -21.54 psf -21.54 psf 16.6 psf X Standoff Spacing= 4.00 4.00 4.00 Y Standoff Spacing= 2.75 2.75 2.75 Tributary Area= 11.00 11.00 11.00 Footing Uplift= -194Ib -237 Ib -237Ib r _---Staridoff Uplift Check Maximum Design Uplift= -237 lb Standoff Uplift Capacity = 400 Ib 400 lb capacity>237 lb demand Therefore,OK Fastener Capacity Check'— -1 Fastener= 1 -5116"dia Lag Number of Fasteners= 1 Embedment Depth= 2.5 Pullout Capacity Per Inch= 250 lb Fastener Capacity= 625 lb w/F.S.of 1.5= 417 lb 417 lb capacity>237 lb demand Therefore,OK Athuluti Residence, Salem 3 EAH Structural Consulting 11 igton'.�.L. Lane Lexington, MAA 02421 PHONE 1.978.406.3921 EA H CONSULTING, Elaine(DEAHstructural.com Framing Check (MP1) PASS w=57 plf Dead Load 11.1 psf PV Load 4.0 psf Snow Load 28.0 psf 2x10 Rafters @ 16"o.c. 0 Governing Load Combo=DL+SL Member Span=13'-0" Total Load 43.1 psf Member Properties Member Size S(inA3) I(inA4) Lumber Sp/Gr Member Spacing 2x10 21.39 98.93 SPF#2 @ 16"o.c. f Check Bending Stress Fb(psi)= fb x Cd x Cf x Cr (NDS Table 4.3.1) 875 x 1.15 x 1.1 x 1.15 Allowed Bending Stress= 1272.9 psi Maximum Moment = (wL.A2)/8 = 1214.68 ft# = 14576.1 in# Actual Bending Stress=(Maximum Moment)/S =681.5 psi Allowed>Actual--53.6%Stressed -- Therefore,OK - Check Deflection Allowed Deflection(Total Load) = U180 (E=1400000 psi Per NDS) = 0.866 in Deflection Criteria Based on = Simple Span Actual Deflection(Total Load) _ (5*w*LA4)/(384*E*1) = 0.267 in = U585 > U180 Therefore OK Allowed Deflection(Live Load) = U240 0.65 in Actual Deflection(Live Load) _ (5*w*LA4)/(384*E*1) 0.174 in U897 > U240 Therefore OK Check Shear i Member Area= 13.9 inA2 Fv(psi)= 135 psi (NDS Table 4A) Allowed Shear = Fv*A = 1873 lb Max Shear(V)=w*L/2 = 374 lb Allowed>Actual--20%Stressed -• Therefore,OK Athuluti Residence, Salem 4 Project Data Codes MA CMR 780 51.00 IBC-2009,ASCE 7-05 2005 NOS,NEC-2016 / N Inverter: Integrated / - W Panel: (29)Sunpower=-250-BLK-AC Racking: Invisimount-Flush To Roof / System Rating: 7.25 kW DC-STC tat Year Production:8,939 kM / Design Factors / Ground Snow Load 40 psf Wnd Speed 100 mph A 3 A f (/\ V Load Center � ' Rooftop Setback ' f unpower Monitor Roof 1 V UtI(Ity Disconnect \ � Azimuth: 190° N Tilt: 36° -Utility Meter Solar Access:96% ✓' 29 Panels- 1.233 Map \ Q BOSTONESOLAR Drawing Name Site Plan Date June 26,2015 CLIENT INFORMATION: Drawn by TP Sumathi Athuluri Checked by 18 Saunders St. REva 00 Salem, MA 01970 PV- 2.0 (978)908-0001 Seale As Noted d.r Module Structure Module Specs Army B.° rcn@rree Structure Type: Rafter Model: SPWR-250-BLK Number of Modules: 29 Rafter Size: 2z10' Length: 61° Total Module Weight: 1122.0 Lbs unino°O�_cao� Rafter Spacing: 16• Width: 31' Total Racking Weight: 97.72 Lbs "mmo Femme ®1OOL Rafter Span: 167' Weight: 38.7 Lbs Amay Area: 388.31 SOFT •"d Mm"' P _".sm"am. M Roof Pitch: 38° Amay Weight: 122.02 Lbs Decking Type: Sheathing Racking Specs Anay Dead load: 3.14 Lbs/SOFT i."x Il � Roof Material: ILyr-Shingle Type: Invisimount Number of Mounts: 57 re'va Bell �6T Number of Floors: 2 Weight: 0.56 Lbs/Ft Load Per Mount; 21.40 Lbs MOUNTING DETAIL kfe+eh.rw Yle�e 8" Fire Lane Boundary 2s yr ZZ s sra• N a Elaine A.Huang MA Professional Engineer License M 49029 wwdnlw Ylonisto Spatlrq Q THI BOST SOLAR i wm.Eoelwuolacue IMc®BO�ena"le,.o. Drawing Name Layout Date October 13,2015 CLIENT INFORMATION: Drawn by MC SumathiAthuluri Checked by 18 Saunders St. Revs 91 Salem, MA 01970 PV - 3.1 (978)908-0001 Scale AsN.Fd Solar Module Intecrated Micro-lmerter Design Conditions Sunpower X20-250-aLR-&AC Rated Output Power 238W Annual extreme temperature 0 high tear 4% 35°C Output Voltage 240V Nominal Output Voltage 240V 9 p t ' Output Freq 60.OHz Nominal Output Current .99A 2%Average high temperature:32°C Output Current .99A Inverter Efficiency 95% Annual extreme low temperature:-17°C CEC Efficiency Rating 95% Max Per Circuit 16 Temperature at 3.5"above roof:49°C (a)eefIWN-2 GmuM wra (3)B4 THWH-2 Wire 111N10T- MT MT (t)tt10 TI-EMT GmuM I-EMT O Met 8 20Q 2 e StriW of Modules 8 Stang of Mraubafl MI..-I.n,xa in Parallel.14 Mlrn Inert..In Parallel:14 j Pnit of l4 ,=— Pn114 o114r= 20A j '•—•-- —•_•_ Solaoeck-Pea TtimUBh Box r••_- 20A $UnPower anibnng I j 1� WABus j Lora Cantor M I 1 Pnitot l5 r w Nmt - Pnl 15 of 15r I Solar Load125 Center ................414 �Salrvke String of Matlules ll Sldne of Moauks 8 125p Mlw-Inveaere In Parallel:l5 Mlao-Inverien in Pere0el:15 Diamnned Diswnnad Raver"Je BUAS,Wcli BOA Swi1cll Monitoring System 40A Fuses SPWR AC Oeble (e)kte THWN-2 Wire (1)910 THWW2 GmUM 1•EMTOUMoor QBOcb.ISOLAR wm�.5aelonaaleru> I Info®BosmScler.us Drawing Name Line Diagram Data October 13,2015 CLIENT INFORMATION: Drawn by MC SumathiAthuluri Cbecked11 18 Saunders St. REva cB Salem, MA 01970 PV - 4.0 (978)908-0001 Scale ABNptea ALL LABELS SHALL BE OUTDOOR RATED WEATHER RESISTANT,UV AND WATER RESISTANT BASE SHEET,INKS, CAUTION Q PV SYSTEM Q AND ADHESIVES. SOLAR ELECTRIC ALL LABELS SHALL BE A RED BACKGROUND WITH WHITE SYSTEM CONNECTED GENERATIONMETER LETTERING PROVIDED. ALL LABELS SHALL BE REFLECTIVE MATERIAL/LETTERING. PHOTOVOLTAIC SYSTEM WARNING DANGER DISCONNECT FOR ELECTRIC SHOCK HAZARD! UTILITY OPERATION Q DO NOT TOUCH TERMINALS Q Q DO NOTDISCONOLTAICNECT DISCONNER LOADECT Q TERMINALS ON BOTH LINE AND LOAD SIDES TURN OFF PHOTOVOLTAIC DISCONNECT SWITCH PRIOR TO SERVING MAY BE ENERGIZED IN THE OPEN POSITION / WARNING /N ELECTRIC SHOCK HAZARD! DO NOT TOUCH TERMINALS.TERMINALS ON WARNING WARNING BOTH THE LINE AND LOAD SIDES MAY BE I Q PV DISCONNECT BACKFED O ENERGIZED IN THE OPEN POSITION - Q ELECTRIC SHOCK HAZARD. Q INTERacnvEsouRPv SYSTEM RanNG BREAKER DO NOT REMOVE OR IF A GROUND FAULT IS INDICATED, RELOCATE CONTINUOUS OUTPUT CURRENT 29 AMP I NORMALLY UNGROUNDED CONDUCTORSMA Y BE GROUNDED AND ENERGIZED NORMAL OPERA TING AC VOLTAGE 1 240V SYSTEM INSTALLER: FOR SERVICE CALL: UTILITY DISCONNECT WARNING LABEL CAUTION WARNING Q Q THIS METER IS ALSO SOLAR ELECTRIC SYSTEM SERVED BYA WARNING WARNING CONNECTED PHOTOVOLTAIC SYSTEM DC SOLAR CIRCUIT INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS DC CIRCUIT LABEL OVERCURRENT DEVICE UTILITY DISCONNECT LABEL Q B09ON`SOLAR WARNING www.msloneoiecue I inkt3eaelonEaler.u. PV SYSTEM DISCONNECT ELECTRIC SHOCK HAZARD Drawing Name Labels Page THE DIRECT CURRENT OIRLUITCONUUCTORSOF Data October 13,2015 FOR UTILITY OPERATION THIS PHOTOWLTAIC=ER SYSTEM ARE CLIENT INFORMATION: Q UNGROUNDEOaUTMAYNEENERGI2EOWITH OlaWl1 by RESPECTIOGROUNDDUETOLEAMCEPATHS Sumathi Athuluri IChec Mby MC AND/OR GROUND FAULTS 18 Saunders St. REV# 00 DC WARNING LABEL Salem, MA 01970 PV - 5.0 (978)908-0001 Scale AS Noted