Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
28 SABLE RD - BUILDING INSPECTION (3)
cl� jXZg C3- ED i �} - 1 s �� I%,,EC1Io%AL SERVICES' The Commonwealth of Massachusetts I q A 08 Board of Building Regulations and Standards CITY OF Massachusetts State Building Code,780 CMR SALERevised Mnr4201/ Building Permit Application To Construct,Repair, Renovate Or Demolish a One-or Two-Family Dwelling This Section For Official Ug Only Building Permit Number: Date Ap ied: to ay/ 4f Building Official(Print Name) Signature Dale SECTION 1:SITE INFORMATION 1.1 g`operty Ad re s: 1.2 Assessors Map&Parcel Numbers L la Is this aan accepted street?yes-- no Map Number Parcel Number 1.3 Zoning Information: 1.4 Property Dimensions: Zoning District Proposed Use _ Lot Area(sq h) Frontage(it) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply:(M.G.L c.40,§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: Public❑ Private❑ Zone: _ Outside Flood Zone?Check ifyes0 Municipal❑ On site disposal system ❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'ofRecord:Julle KIricopleS Salem MA. Name(Print) Cil ,Stale,ZIP 28 Sable Rd. 978-740028 JuIie.kiricoples@yahoo.com No.and Street Telephone Email Address SECTION 3:DESCRIPTION OF PROPOSED WORK''(check all that apply) New Construction j8( Existing Building Owner-Occupied Cl I Repairs(,) ❑ Alteration(,) ❑ Addition ❑ Demolition ❑ Accessory Bldg.❑ Number of Units_ I Other ❑ Specify: Brief Description of Proposed Work': S OUVOCd DVlO'�DynL�-QIG SolQt' .SyS —t A O (?a— SECTION 4:ESTIMATED CONSTRUCTION COSTS Item Estimated Costs: Official Use Only labor and Materials) I.Building $" .00 1. Building Permit Fee:$ Indicate how fee is determined: 2.Electrical $ - ❑Standard City/Town Application Fee ❑Total Project Cost'(Item 6)x multiplier x 3. Plumbing $ 2. Other Fees: $ 4.Mechanical (HVAC) $ List: 5.Mechanical (Fire Suppression) $ Total All Fees:$ Check No._Check Amount: Cash Amount:_ 6.Total Project Cost: $�, C r'vl 0 Paid in Full 0 Outstanding Balance Due: SECTIONS: CONSTRUCTION SERVICES 5.11_Construction Supervisor License(CSL) O�S 2`5 4 2$ lA .Jct-me �' V\PXY�Qi'1 License Number ExpV anon at Name of CSL Holder List CSL l"ype(see below) y No.and Street "IYPe Desc iplion S--114 S � �`�l A I A QI C]l W Q 1 _' U Unrestricted(Buildings u to 35,000 cu.R. _ R Restricted 1&2 Famil Dwellin City/Town,S t' %1P M Mason ty RC Roofing Covering WS Window and Siding ',�e���`ttl'lAru" SF Solid Fuel Burning Appliances Vn lY,�tiCf�jarp—VIVt. , I Insulation Tele hone Email address Corn D Demolition 5.2 Registered Home Improvement Contractor(HIC) l.vLVLt H4 . S . D2Ve 1W?Y HIC Registration Number HIC R gistranl Name gC3m a. NAeDO �t E,pirat on ate Yv�0.SolascQ. vwtvlFso r. Nn.and Street Entail address (_Drvt �oVo L?'� 56`4'(DOI{ -l$13053o(g5 City/Town,State,ZIP Telephone SECTION 6:WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152.g 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building permit. Signed Affidavit Attached? Yes ..........A No...........❑ SECTION 7a:OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT 1,as Owner of the sub ject property,hereby authorize y1 V 1✓r Sfl 1GLr to act on my behalf,in all matters relative to work authorized by this building permit application. tG✓ 9/15/14 Print Owner's N to(Electro tgm lure) Date SECTION 7b:OWNER'OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in IN pl lion is true and accurate to the best of my knowledge and understanding. VIVIInt n, q. I Print Ow s r rued Agent's Namee(Electronic Signature) 'Date NOTES: I. An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered contractor (not registered in the Home Improvement Contractor(HIC)Program); will not have access to the arbitration program or guaranty fund under M.G.L.c. 142A. Other important information on the HIC Program can be found at www.mass.pov/oca Information on the Construction Supervisor License can be found at www.mass eovfdos 2. When substantial work is planned,provide the information below: Total floor area(sq.ft.) (including garage,finished basement/atties,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths 'Type of heating system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"maybe substituted for"Total Project Cost" '' CERTIFICATE OF LIABILITY INSURANCE °Alro1no 3° """ THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the poliey(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTA MARSH USA INC. NAME: 122517TH STREET,SUITE 1300 PHGNE FAX DENVER,CO 80202-5534 E+aAIL Arc No: Attn:Denvar.certrequest@marsh.com,Fax:212.948A381 ADDRESS: INSURE AFFORDING COVERAGE NAICS 462738-STND-GAWUE-13-14 INSURERA:Evanston Insurance Company 3r,O7a INSURED INSURER a:National Union Fire Insurance Go of PA Vivint Solar,Inc. 4931 N 300 W INSURER C:New Hampshire Insurance Company 23841 Provo,UT 84604 INSURER D: INSURER E: INSURER F: ' COVERAGES CERTIFICATE NUMBER: SEA-002368030-06 REVISION NUMBER:0 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED-BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR DOL SUM POUCYEFF POLICY EXP LTR TYPE OF INSURANCE POLICY NUMBER MM/D MMID UMn3 A GENERAL LIABILITY 13PKGWE00274 11/01/2013 110/2014 EACH OCCURRENCE $ 1,000.000 X COMMERCIAL GENERAL LIABILITY PREMISES Ea aneme !I50�000 ccu CLAIMS-MADE M OCCUR MED EXP(Any one person) $ 5,000 PERSONAL&ADV INJURY $ 1,000,000 GENERAL AGGREGATE $ 2,000,000 GENL AGGREGATE LIMIT APPLIES PER: PRODUCTS-OOMP/OPAGG S 2,00g= X POLICY PRO-1pr.TLOC $ B AUTOMost-E LIABILITY 9701087 1110112013 IV0112014 FOMaBrJEDi[SINGLE LIMIT 1,000,000 8 X ANY AUTO 9701088 11/01/2013 11/012014 BODILY IWURY(Perperson) E ALL OWNED SCHEDULED AUTOS AUTOS BODILY INJURY(Perathadem) S X HIRED AUTOS N AUUTOS�ED PROPERTY DAMAGE E Per actldem A UMBRELLA LJAS % OCCUR 13EFXWE00088 1110112013 11101/2014 EACH OCCURRENCE $ 10,000,000 X EXCESS LIAR CI-AIMS-MAD AGGREGATE $ 10,000,000 DELI RETENTION$ $ C WORKERS COMPENSATION 029342334; 029342335 11M12013 11/0112014 X NYETATLIMU OTH- C AND EMPLovERS wIallm YIN .02934233fi; 029342337 11/012013 11/0112014 ANY PROPRIETOR/PARTNER/EXECUTIVE E.L.EACH ACCIDENT $ 1,000,000 D OFFICERIMEMBER EXCLUDED? � N/A (Mandatory In NH) 029342338 11/01/2D13 11/01/2014 E.L DISEASE-EA EMPLOYE $ 1,000,000 d Yea,deaaibe coder DESCRIPTION OF As below E.L.DISEASE-POLICY OMIT E 1,000,000 A Enars&Omissions& 13PKGW00029 11/01/2013 11/alM14 LIMIT 1,000,000 Contractors Pollution DEDUCTIBLE 5,000 DESCRIPTION OF OPERATIONS/LOCATIONS/VEHICLES(Attach ACORD 101,Additional Remade Schacht.,a more apace is required) The Certificate Holder and others as defined in the written agreement me included as additional insured where required by written contract wiN respect to General Liability.This insurance is primary end non- ntributory over any existing insurance and limited to liability arising out of the operations of the named insured end where required by written contract Waiver of subrogation is applicable where required by written Iract with respect to General Liability end Workers Compensation. CERTIFICATE HOLDER CANCELLATION City of Salem SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 93 Washington Street THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Salem,MA 01970 ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE of Marsh USA Inc. Kathleen M.Parsbe ©1988-2010 ACORD CORPORATION. All rights reserved. ACORD 25(2010/05) The ACORD name and logo are registered marks of ACORD L The Commonwealth of Massachusetts Department of IndustrialAccidents Office of Investigations I Congress Street, Sitite 100 Boston,MA 02114-2017 wwwmass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organization/Individual): Vivint Solar Developer LLC Address: 4931 North 300 West City.+'State,//i :_Provo _UT84604 _ Phone#; 801-704-9389 Are you an employer?Check the appropriate box: Type of project(required): ' 1. XX I am a employer with 10 4. ❑ I am a general contractor and 1 employees (full and/or part-time).* have hired the sub-contractors 6. ❑ New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees Ihcse.sub-contractors have g, ❑ Demolition working for me in any capacity. employees and have workers' 9 ❑ Building addition [No workers' comp. insurance comp. insurance.$ required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ 1 am a homeowner doing all work officers have exercised their 1 LE] plumbing repairs or additions myself. o workers' com right of exemption per MGL y � P 12.❑ Roof repairs insurance required.] t c. 152, §1(4),and we have no employees. [No workers' 13.❑ comp. insurance required.] *Any applicant that checks box 41 must also till out the section below showing their workers'compensation policy information. r Homeowners who submit this affidavit indicating they are doing at work and then hire outside contractors must submit anew affidavit indicating such. tContractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they most provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. i Insurance Company Name:___New Hampshire Insurance Company________ Policy#or Self-ins. Lie. #: 029342228 Expiration Date: 11/01/14 — ---------- Job Site Address:_ City/State/Zip:_ r r J Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify under pains r ❑l penrdtic of perjury t t the information provided above is true and correct. Phone??: 01.704-9389 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License Issuing Authority(circle one): 1. Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector 5.Plumbing Inspector 6.Other_ Contact Person: — — Phone#: kiiii 0 V1 �VY15U111G1 till0.11J aliu 13115111G55 17v�Ulat,W11 A� 10 Park Plaza - Suite 5170 Roston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170848 Type: Supplement Card VIVINT SOLAR DEVELOPER LLC. Expiration: 1/5/2016 JAMES SHERMAN 4931 NORTH 300 WEST PROVO, LIT 84604 Update Address and return card.Mark reason for change. scn 1 0 2OM-05/11 ❑ Address ❑ Renewal Employment Lost Card Massachusetts -Department of Public Safety �✓ Board of Building Regulations and Standards Construction Supen'isor License:CS-045254 JAWS R SHERMAN �w 6 Fox Hollow Drive c, - SAUGUS MA 01"6 PJ Expiration Commissioner 08/2 812 0 1 6 ` Cl i Cl oll t. solar 4931 North 300 West Structural Group Provo,UT84604 P: (801)234-7050 Scott E. Wyssling, PE Head of Structural Engineering scott.wyssling@vivintsolar.com September 15, 2014 Mr. Dan Rock, Project Manager Vivint Solar 24 Normac Road Woburn MA 01801 Re: Structural Engineering Services Kiricoples Residence 28 Sable Road, Salem MA AR#3229771 5.5 kW System Dear Mr. Rock: Pursuant to your request, we have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site VisitNerification Form prepared by a Vivint Solar representative identifying specific site information including size and spacing of rafters for the existing roof structure. 2. Design drawings of the proposed system including a site plan, roof plan and connection details for the solar panels. This information was prepared by the Design Group and will be utilized for approval and construction of the proposed system. 3. Photovoltaic Rooftop Solar System Permit Submittal identifying design parameters for the solar system. 4. Photographs of the interior and exterior of the roof system identifying existing structural members and their conditions. Based on the above information we have evaluated the structural capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: Description of Residence: The existing residence is typical wood framing construction with the roof system consisting of 2 x 6 dimensional lumber at 16" on center with 1 x 8 collar ties every 32". The attic space is unfinished and photos indicate that there was free access to visually inspect the size and condition of the roof rafters. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir #2 or better with standard construction components. Our review of the photos of the exterior roof does not indicate any signs of settlement or misalignment caused by overstressed underlying members. Stability Evaluation: A. Wind Uplift Loading 1. Refer to attached Ecolibrium Solar calculations sheet for ASCE/SE17-10 Minimum Design Loads for Buildings and other Structures, wind speed of 100 mph based on Exposure Category "B" and 23 degree roof slopes on the dwelling areas. Ground snow load is 40 PSF for Exposure"B", Zone 2 per (ASCE/SE17-10). 2. Total area subject to wind uplift is calculated for the Interior, Edge and Corner Zones of the dwelling. vivint. solar •� Page 2 of 2 B. Loading Criteria • 10 PSF= Dead Load roofing/framing 40 PSF=Live Load (around snow load) • 5 PSF=Dead Load solar Panels/mounting hardware Total Dead Load=15 PSF The above values are within acceptable limits of recognized industry standards for similar structures. Analysis performed of the existing roof structure utilizing the above loading criteria indicates that the existing rafters will support the additional panel loading without damage, if installed correctly. C. Roof Structure Capacity 1. The photographs provided of the attic space and roof rafters show that the framing is in good condition with no visible signs of damage caused by prior overstressing. D. Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent "Ecolibrium Solar Installation Manual', which can be found on the Ecolibrium Solar website (ecolibriumsolar.com). It during solar panel installation, the roof framing members appear unstable, deteriorated, structurally compromised or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. Maximum allowable pullout per lag screw is 235 Ibs/inch of penetration as identified in the National Design Standards (NDS) of timber construction specifications for Hem-Fir (North Lumber) assumed. Based on our evaluation, the pullout value, utilizing a penetration depth of 2 Yz', is less than what is allowable per connection and therefore is adequate. Based on the variable factors for the existing roof framing and installation tolerances, using a thread depth of 2 Yz' with a minimum size of 5/16" lag screw per attachment point for panel anchor mounts should be adequate with a sufficient factor of safety. 3. Considering the roof slopes, the size, spacing, condition of roof, the panel supports shall be placed at and attached to no greater than every fourth roof rafter as panels are installed perpendicular across rafters and no greater than the panel length when installed parallel to the rafters (portrait). No panel supports spacing shall be greater than four (4) rafter spaces or 64"o/c, whichever is less. 4. Panel supports connections shall be staggered to distribute load to adjacent rafters. Based on the above evaluation, it is the opinion of this office that with appropriate panel anchors being utilized the roof system will adequately support the additional loading imposed by the solar panels. This evaluation is based on information supplied to us at the time of this report and current industry standards and practices. Should you have any questions regarding the above or if you require further information do not hesitate to contact me. Ve truly yours, SNOFSfy � cy Y CIVI N ScottE. Wyssl' PE a.so MA License N . 50 9oF FCIsl FSSIONAk vivi t. so 1 d r 28 Sable Rd_ , Salem— MA_ 01970 U PV INTERCONNECTION POINT, 3'OF 1'PVC CONDUIT LOCKABLE DISCONNECT SWITCH, I FROM JUNCTION BOX TO ELEC PANEL I ANSI METER LOCATION, &UTILITY METER LOCATION (n mw mfz I I fnmmz "Ao Q U I I U Y 5 I I JUNCTION BOX ATTACHED TO- ARRAY USING ECO HARDWARE TO KEEP JUNCTION BOX OFF ROOF I I C •O m 22)Tnna Solar TSM-250 PA05.1B MODULES WITH A I m Enohase M215-60-2LL-S2z ZC MICRO-INVERTER MOUNTED ON THE BACK OF EACH MODULE m n n I I 5 m y � U f w Z m 3 z J w � z W . I I W W Z m J J W Z F F � 3 m m ¢ z_ z � SHEET NAME: PV SYSTEM SIZE: 5.5kWDC ___-_-_-_ _ -_ __-_ ___--- PV SYSTEM SITE PLAN SCALE: 1/8"= 1'-0" f 0 00 om 0c z Cy bO yN O m T E A a �J o °o O y�0 =N �.5O O m� O c � � N D7 2 Z N N m m Z ti N n V D � r � m { rn M N n 01 01 o ; cc m� O u O T T r D Z �= Di INSTALLER'VIVINTNR . . Kirico les Residence m m ROOF m m INSTALLER NUMBER:1.877.404.4129 `a 28 Sable Rd PV 2.� y MA LICENSE:MANIC 1]0848 vhvin . t� �A � Salem,MA 01970 PLAN DRAWN BY:EF I AR 3229771 Last Motli6etl:9IBY2014 UTILITY ACCOUNT NUMBER:8810690001 CLAMP N MOUNTING c: SEALING C PV3.0 DETAIL WASHER (D $ LOWER fn �� SUPPORT N�om ® U)2E� PV MODULES, TYP. MOUNT " ""'`" """` d u OF COMP SHINGLE ROOF, FLASHING p PARALLEL TO ROOF PLANE V J 2 1/2" MIN Y S 5116"0 x 4 1/2" MIN PV ARRAY TYP. ELEVATION STEIEL MUM LAG SCREWS NOT TO SCALE TORQUE= 13±2 ft-Ibs O CLAMP ATTACHMENT ul NOT TO SCALE 0 R •o W CLAMP+ `9 ATTACHMENT CANTELEVER L/4 OR LESS COUPLING j L=PERMITTED CLAMP ECO SPACING SEE CODE COMPLIANT COMPATIBLE LETTER FOR MAX ALLOWABLE MODULE CLAMP SPACING. PERMITTED COUPLING ¢ ^ o m Sm CLAMP+ CLAMP CLAMP y ATTACHMENT SPACING z m r COUPLING PHOTOVOLTAIC MODULE ; w z w w w z m 0w z �a � o 3 SHEET NAME: L=PORTRAIT � CLAMP SPACING Zo Q o F ECO O Mo ULEPATIBLE PV SYSTEM MOUNTING DETAIL SHEET L=LANDSCAPE NUMBER CLAMP SPACING MODULES IN PORTRAIT/LANDSCAPE NOT TO SCALE 1 M NOT TO SCALE a Inverter Ratings(Guide Section 4) Conduit and Conductor Schedule Inuerler Volt Ratio,on. EnpM1au M21S60.2LLe2x-ZC Ti Oeacnplion Wm Gauge pot Contlutton ConEuil Type Condor elze MODULE DETAIL Max DO Volt Rmma 4s vale Max Powera40'C 215 Wetls 1 Enpbase engage®de-THWN1 12 AWG 4 C.ob NIA-Frog Air U Nominal AC VWage 2. vats I Bare Copper Ground EGCIGEC) 6AWG I Nirea Air NIA-Fme Air ^` Tona S.lar.TSM-250 PA05.18 Max AC Cument 08 Amps 2 THWN2 1p AWG 6 PVC 0'-I' W SOLAR MODULE MaxOi mon, 20 Amps OAWG PVC 0'-1' T re Max Number of ParmahGoruil 17 2 THWN2-Ground 1 y 3 THWN2 BAWG 3 PVC ow p NOTES FOR INVERTER CIRCUITS(Guide Section Band 91: 3 THWN2-Ground 8AWG 1 Pvc o-f' row �moM 1.)IF UTILITY REQUIRES AIREMELE-BREAK SWITCH,GOES THIS a PV Module Ratings @ STC(Guide Section 5) Enphase M215TER AT SWITCH MEET THE REQUIREMENTS? n E z YES NO XNA Motlel Mak-Pointl Trine Solar TSM 250 PA05.iff V) F MICRO-INVERTER AT (n m�z Max PowerPONt Currtnt(Imp) 82] Am s EACH MODULE,ATTACHED p `"—7 WITH ECO HARDWARE 2.)IF GENERATION METER REQUIRED,GOES THIS METER Max Power-POlot Voltage(Vmp) 30.J Volb y0 SOCKET MEET THE REQUIREMENTS2 Open-Circuit V0ltage(Voc) 37.6 vec Q VES NO XNA SM1otl-CVcuil Current 1.) 8,85 Am Q ps BASED N CURRENT TON NEC6SOURCE.53 SIG CONDUCTORS Max Series Five Maximum Favor IS Amps V BASED ON MAXMACONNECT. ON NEC 890.5351GN OR OCPO Nominal Maximum Power at STC Proof) 250 Watt% MICROINVERTER CONNECTION _ RATING AT DISCONNECT. Maximum system voltage I0000EC)Is00(u1 L_ TO ENGAGE TRUNK CABLE 4.)SIZE INVERTER OUTPUT(AC)CONDUCTORS ACCORDING Voc Temperature CoeBmienr -O.J2 %I'C Y ^ TO INVERTER OCPO AMPERE RATING(So.Guide Section 9). V 5JTOTALOF 2 INVERTER OCPD(s).ONE FOR EACH NOTES FOR ARRAY CIRCUIT WIRING fGulde Section Sand Band Appendix Dc PV CIRCUIT.DOES TOTAL SUPPLY BREAKERS COMPLY S WITH 120%BUSBAR EXCEPTION IN 1.)Lowest expected ambient temperature based on ASHRAE minimum mean extreme #6 BARE CU GROUND NEC690.64(B)(2$a)? XVES NO dry bulb temperature for ASHRAE location most similar to installation location: -19°C (7 ' (GROUNDING ARRAY) Signs(See Guide Section 7) 2.)Highest continuous ambient temperature based on ASHRAE highest month 2%diy bulb temperature for ASHRAE location most similar to Installation location 39°C • �� Sign for inverter OCPD and AC Disconnect: 3)2005 ASHRAE fundamentals 2%design temperatures do not exceed 47°C in the al Unfol Slates,(Palm Springs,CA is 44.1 Of For less than 9 cunent-cam conductors r� Solar PV System AC Point of Connection in roof-mounted sums conduit at least 3.5'above roof and using the outdoor draign AOOutput Current 19600000 1 Amps temperature of 47"C or less(all of United States), Nominal AG Voltage 2hot Volts a)12 AWG,90°C conductors are generally acceptable for modules with Ise of 768 Amps a .I less when pro90-C co tl by a s am g or smaller fuse. THIS PANEL FED BAND LTIPLE SOLAR) p,)10 AWG.90°C conductors era generally acceptable for modules with lap of 9.6 Amps UTILITY AND SOLAR) or less when protectedb a 151 or smaller fuse. NOTE:NEUTRAL CONDUCTOR(S)OMITTED FOR CLARITY a ALL INVERTER OUTPUT CIRCUITS WILL HAVE A NEUTRAL CONDUCTOR �>> e M PV CIRCUIT 1: 12 MODULES/PARALLEL $ ENVOY BOX S as n U - m < Le./s • • • s s \ C I MURRAY SIEMENS w w z m ---- ---T \\y0 BOG COMBINER UNFUSED 6aA/240V a a 3 6O40V SIEMENS PO\NN'/Q PANEL 125A1240V NEMA3 FUSED NEMA3 z z PV CIRCUIT 2: 10 MODULES/PARALLEL I O\K e LWO04NR SREC/ANSI LNF222R OR GF222R OR EXISTING TO\A�PG( OR EQUIVALENT METER EQUIVALENT EQUIVALENT O ENTRANCE NAME i t M CONDUCTORS j \0 RATED:100A W 10 • • • Q2 O 1 \\ 15A Z J (� \ 15A SUPPLY-SIDEQ . . . E 1.0 1 \\ 30A SOLAR TAP I xec 2ps.1zµ1 SHEET ___ —_ ___ ___ __ ______ ____ _ _______ _ NUMBER' \ 240V/100A \ MILBANK VISIBLE/LOCKABLE �_ PANEL JUNCTION BOX 2 \\ 3 100A OR 3 'KNIFE'A/C 3 3 NEC 2014 Compliant WITH IRREVERSIBLE \ EQUIVALENT DISCONNECT TO EXISTING GROUND SPLICE E 1.0 \ E 1.0 U5934-XL-BLG E 1.0 E 1.0 E 1.0 LOAD-CENTER I.1.1 I Vivint Solar - PV Solar Rooftop System Permit Submittal 1. Project Information Project Name: Julie Kiricoples Project Address: 28 Sable Rd,Salem MA A.System Description: The array consists of a 5.5 kW DC roof-mounted Photovoltaic power system operating in parallel with the utility grid.There are(22)250- watt modules and(22)215-watt micro-inverters,mounted on the back of each PV module.The array includes(2) PV circuit(s).The array is mounted to the roof using the engineered racking solution from Ecohhrium Solar. B.Site Design Temperature: (From Boston Logan INTL ARPT weather station) Average low temperature: -21.1 °C (-5.98°F) Average high temperature: 38.4°C (101.12°F) C.Minimum Design Loads: Ground Snow Load: 40 psf (State Board BR&S) Design Wind Speed: 100 mph (State Board BR&S) 2.Structural Review of PV Array Mounting System: A.System Description: 1.Roof type: Comp.Shingle 2.Method and type of weatherproofing roof penetrations: Flashing 8. Mounting System Information: 1.Mounting system is an engineered product designed to mount PV modules 2.For manufactured mounting systems,following information applies: a.Mounting System Manufacturer: Ecoljbrium Solar b.Product Name: Ecorall c.Total Weight of PV Modules and mounting hardware: 946 Ibs - d.Total number of attachment points: 44 e.Weight per attachment point: 21.5 Ibs E Maximum spacing between attachment points: * See attached engineering talcs g.Total surface area of PV array: 387.42 square feet h.Array pounds per square foot: 2.44 Ibs/square foot i.Distributed weight of PV array on roof sections: -Roof section 1: (22)modules,(44)attachments 21.5 pounds vivint. solar 3. Electrical Components: A.Module (UL 1703 Listed) Qty Trina TSM 250-PA05.18 22 modules Module Specs Pmax-nominal maximum power at STC - 250 watts Vmp-rated voltage at maximum power - 30.3 volts Voc-rated open-circuit voltage - 37.6 volts Imp-rated current at maximum power - 8.27 amps Ise-rate short circuit current - 8.85 amps B. Inverter (UL 1741 listed) Qty Enphase M215-60-21 J.S22 22 inverters Inverter Specs 1. Input Data (DC in) Recommended input power(DC) - 260 watts Max.input DC Voltage - 45 volts Peak power tracking voltage - 22V-36V Min./Max.start voltage - 22V/45V Max.DC short circuit current - 15 amps Max.input current - 10.5 amps 2. Output Data (AC Out) Max.output power - 215 watts Nominal output current - 0.9 amps Nominal voltage - 240 volts Max.units per PV circuit - 17 micro-inverters Max.OCPD rating - 20 amp circuit breaker C.System Configuration Number of PV circuits 2 PV circuit 1 - 12 modules/inverters (15)amp breaker PV circuit 2 - 10 modules/inverters (15)amp breaker 2011 NEC C Article 705.60(B) vivin#. solar D. Electrical Calculations 1.PV Circuit current PV circuit nominal current 10.8 amps Continuous current adjustment factor 125% 2011 NEC Amide 705.60(B) PV circuit continuous current rating 13.5amps 2.Overcurrent protection device rating PV circuit continuous current rating 13.5 amps Next standard size fuse/breaker to protect conductors 15 amp breaker Use 15 amp AC rated fuse or breaker 3.Conductor conditions of use adjustment(conductor ampacity derate) a.Temperature adder Average high temperature 38.4°C (101.12°F) Conduit is installed 1"above the roof surface Add 22°C to ambient 2011 NEC A,fide 705.60(B) Adjusted maximum ambient tcmperamre 60.4°C (140.72°F) b.PV Circuit current adjustment for new ambient temperature Derate factor for 604°C (140.72°F) 71% 2011 NEC Arude 705.W(B) Adjusted PV circuit continuous current 19 amps c.PV Circuit current adjustment for conduit fill Number of current-carrying conductors 6 conductors Conduit fill derate factor 800/ 2011 NEC Arudc 705.60(B) Final Adjusted PV circuit continuous current 23.7 amps Total derated ampacity for PV circuit 23.7 amps Conductors(tag2 on 1-line)must be rated for a minimum of 23.7 amps THWN-2(90°C) #14AWG conductor is rated for 25 amps (Use#14AWG or larger) 2011 NEC Ardde 705.60(B) 4.Voltage drop(keep below 3%total) 2 pans: 1.Voltage drop across longest PV circuit micro-inverters(from modules to j-box) 2.Voltage drop across AC conductors (from j-box to point of interconnection) 1.Mirco-inverter voltage drop: 0.48% The largest number of micro-inverters in a row in the entire array is 10 inCircuit 2.According to manufacturer's specifications this equals a voltage drop of 0.48%. 2.AC conductor voltage drop: = [x R x D (+240 x 100 to convert to percent) _(Nominal current of largest circuit)x(Resistance of#14AWG copper)x(Total wire run) _ (Circuit 1 nominal current is 10.8 amps) x(0.0031952)x(86) -(240 volts)x(100) 1.23% Total system voltage drop: 1.71% vivint. solar 008 EcolibriumSolar Customer Info Name: 3229771 Email: Phone: Project Info Identifier: 10901 Street Address Line 1:28 Sable Rd Street Address Line 2: City: Salem State: MA Zip:01970 Country: United States System Info Module Manufacturer: Trina Solar Module Model: TSM-250 PA05.18 Module Quantity: 22 Array Size (DC watts): 5500.0 Mounting System Manufacturer: Ecolibrium Solar Mounting System Product: EcoX Inverter Manufacturer: Enphase Energy Inverter Model: M215 Project Design Variables Module Weight: 41.0 Ibs Module Length: 64.95 in Module Width: 39.05 in Basic Wind Speed: 110.0 mph Ground Snow Load: 40.0 psf Seismic: 0.0 Exposure Category: B Importance Factor: II Exposure on Roof: Partially Exposed Topographic Factor: 1.0 Thermal Factor for Snow Load: 1.2 Lag Bolt Design Load-Upward: 820 Ibf Lag Bolt Design Load-Lateral: 300 Ibf EcoX Design Load- Downward: 493 Ibf EcoX Design Load- Upward: 568 Ibf EcoX Design Load- Downslope: 353 Ibf EcoX Design Load- Lateral: 233 Ibf Module Design Moment—Upward: 3655 in-lb Module Design Moment—Downward: 3655 in-lb Effective Wind Area: 20 ft2 Min Nominal Framing Depth: 2.5 in Min Top Chord Specific Gravity: 0.42 Plane Calculations (ASCE 7-10): 1 Roof Type: Composition Shingle Average Roof Height: 25.0 ft Least Horizontal Dimension: 19.0 ft Roof Slope: 23.0 deg Truss Spacing: 17.0 in Edge and Corner Dimension: 3.0 ft Snow Load Calculations Description Interior Edge Corner Unit Flat Roof Snow Load 33.6 33.6 33.6 psf Slope Factor 0.86 0.86 0.86 Roof Snow Load 28.9 28.9 28.9 psf Wind Pressure Calculations Description Interior Edge Corner Unit Net Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Net Design Wind Pressure Downforce 11.4 11.4 11.4 psf Adjustment Factor for Height and Exposure Category 1.0 1.0 1.0 Design Wind Pressure Uplift -19.4 -31.9 -47.9 psf Design Wind Pressure Downforce 11.4 11.4 11.4 psf ASD Load Combinations Description Interior Edge Corner Unit Dead Load 2.3 2.3 2.3 psf Snow Load 28.9 28.9 28.9 psf Downslope: Load Combination 3 11.3 11.3 11.3 psf Down: Load Combination 3 26.6 26.6 26.6 psf Down: Load Combination 5 9.0 9.0 9.0 psf Down: Load Combination 6a _ 25.6 25.6 25.6 psf Up: Load Combination 7 _ -10.4 -17.9 -27.5 psf Down Max 26.6 26.6 26.6 psf Spacing Results(Landscape) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 63.6 63.6 62.7 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 51.0 51.0 51.0 in Max Cantilever from Attachment to Perimeter of PV Array 21.2 21.2 20.9 in Spacing Results(Portrait) Description Interior Edge Corner Unit Max Allowable Spacing Between Attachments 41.0 41.0 41.0 in Max Spacing Between Attachments With Rafter/Truss Spacing of 17.0 in 34.0 34.0 34.0 in Max Cantilever from Attachment to Perimeter of PV Array 13.7 13.7 13.7 in \ Lank \ \ . 2 � < a \\< � > : : \\ \ > © ? \\� . <� . � _ Skirt _ Coupling Warning: R Modules may_de be shifted with respect to roof trusses to comply with 0 ma mom Ae»_+9 • Distributed Weight (All Planes) In Conformance with Solar ABC's Expedited Permit Process for PV System (EPP) Weight of Modules: 902 Ibs Weight of Mounting System: 88 Ibs Total System Weight: 990 Ibs Total Array Area: 387 ft2 Distributed Weight: 2.55 psf Number of Attachments: 44 Weight per Attachment Point: 23 Ibs Bill Of Materials Part Name Quantity ESEGOt CLASA EcoX Clamp Assembly 44 ESEG01 COASA EcoX Coupling Assembly 28 ESEG01 SKKTA EcoX Landscape Skirt Kit 10 ESEG01 SKKTA EcoX Portrait Skirt Kit 0 ESEG01 CPKTA EcoX Composition Attachment Kit 44 ESEG01 ELASA EcoX Electrical Assembly 1