13 PLEASANT ST - BUILDING INSPECTION (2)
c K 51.1 '�?�CEIVEt� The Commouwealth of Massachusetts r"I SE ilf� rim l Board of Building Regulations and Standards CITY OF Massachusetts State Building Code_780 CMR Zfiifs ; (I� - I �• evr dd �YU _ Building Permit Application To Construct, Repair, Renovate Or Demolish a One-or Two-Fatnily Dwelling This Section For Official Use Outs- Building Permit Number: I)dIc Applied: Building Official(Print Name) Signature Date SECTION 1: SITE INFORMATION 1.1 Property Address: 1.2 Assessors Map & Parcel Numbers 13 Pleasant Street Apt S1 1,1 a Is this an accepted street?ves no Map Number Parcel Number 1.3 boring Information: LA Property"Dimensions: Zonim,District Proposed Use Lot Area(sq ft) Frontage(ft) 1.5 Building Setbacks(ft) Front Yard Side Yards Rear Yard Required Provided Required Provided Required Provided 1.6 Water Supply: (M.G.L c.40.§54) 1.7 Flood Zone Information: 1.8 Sewage Disposal System: public❑ Private❑ Zone: _ Outside Flood Zone? Municipal ❑ On site disposal.system ❑ Check if yes❑ SECTION 2: PROPERTY OWNERSHIP' 2.1 Owner'of Record: Susan Engelke Salem, MA 01970 Name(Print) City,State.ZIP 13 Pleasant Street Apt S1 781-535-1422 No.and Street telephone Email Address SECTION 3: DESCRIPTION OF PROPOSED WORK' (check all that apply) New Construction❑ Existing Building❑ Owner-Occupied ❑ Repanr (s) ❑ Alteration(s) ❑ Addition ❑ Demolition ❑ Accessory Bldg. ❑ Number of Units Other N(spaify: Solar Brief Description of Proposed Work`: Install 3.12 kw solar panels on roof. Will not exceed roof panel, but will add 6" to roof height. 12 panels total. SECTION 4: ESTIMATED CONSTRUCTION COSTS Estimated Costs: Item (Labor and Materials) Official Use Only L Building $ 1,000 1. Building Permit Fee: $ Indicate how fee is determined: ❑ Standard Citv/Town Application Fee 2. Electrical $ 10,000 ❑Total Project Costs(Item 6)x multiplier x 3.Plumbing $ 2. Other Fees: $ C) 4. Mechanical (1--N _/ AC) $ List: Q 5.Mechanical (Fire $ Su Iressionl Total All Fees: $ Check No. Check Amount: Cash Amount: 6. Total Project Cost: $ 11,000 0 Paid in Full 0 Outstanding Balance Due: SECTION 5: CONSTRUCTION SERVICES 5A Construction Supervisor License(CSL) 103631 8/30/17 - Gregg LaCasse License Number Expiration Date Name of CSL Holder List CSL"Cype(see below) U 20 Patterson Brook Rd. Unit 1 Type Description No.and Street U Unrestricted(Buildings up to 35,000 cu.ft. W.Wareham,PA 02576 R Restricted 1&2 Family Dwelling City/town_State i" P M Masomv RC Roofing CoN ering W S Window and Siding SF Solid Fuel Burning Appliances (508)291-0007 1 hrsulation te-le hone Email address D Demolition 1.2 Registered Home Improvement Contra for(HIC) 170355 10/12/17 Gregg LaCasse/Trinity Solar HIC Registration Number Expiration Datc HIC Company Name or HIC Registrant Name 20 Patterson Brook Rd. Unit 1 laurie.avery@trinitysolarsystems.com No.and Street Email address W. Wareham, MA 02576 (508)291-0007 Citv/Town,State,LIP Telephone SECTION 6: WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c. 152. ¢ 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the Issuance of the building peanut. Signed Affidavit Attached? Yes ..........1sr No_____. ❑ SECTION 7a: OWNER AUTHORIZATION TO BE COMPLETED WHEN OWNER'S AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I,as Owner of the subject property;hereby authorize Gregg LaCasse to act on my behalf,in all matters relative to work authorized by this building pennit application. Please see attached letter. 3/29116 Print Owner's Name(Electronic Signature) Date SECTION 7b: OWNER' OR AUTHORIZED AGENT DECLARATION By entering my name below,I hereby attest under the pains and penalties of perjury that all of the information contained in this application is true an a curate to the best of my knowledge and understanding. Gregg LaCasse 3/29/16 Print Owner's or Authorized Agent's Name(Electronic Signature) I)ate NOTES: L An Owner who obtains a building permit to do his/her own work,or an owner who hires an unregistered Contractor (not registered in the Home Improvement Contractor(HIC)Program),will not have access to the arbitration program or guaranty fund under M.G-L-c. 742A. Other important information on the HIC Program can be found at 1L w.mass. ovg /oca Information on the Construction Supeii isor License can be found at www.massaov/dps 2-7 When substantial work is planned,provide the information below: Total floor area('sq. ft.) (including garage,finished bascmcnUattics,decks or porch) Gross living area(sq. ft.) Habitable room count Number of fireplaces Number of bedrooms Number of bathrooms Number of half/baths Type of hearing,system Number of decks/porches Type of cooling system Enclosed Open 3. "Total Project Square Footage"may be substihrted for"Total Project Cost" CERTIFICATE OF LIABILITY INSURANCE DATE IMMID Y)2015 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER($), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must be endorsed. If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Barbara Hayden NAME: HOE o (732)462-2343 ac Na: (732)TSo-9tl1n DITTMAR AGENCY P 78 Court Street AIL ADDRESS:bahayden@dittrnarinsurance.corn P.O. BOX 1180 INSURERS AFFORDING COVERAGE NAIC# Freehold NJ 07728 INSURERA HDI-Gerlinq America Insurance Co. INSURED INSURER B:Llo d''3 London Trinity Heating & Air Inc. , DBA: Trinity Solar INSURERC:North River Insureance Co. BPTP Future Holdings, LLC INSURER D: 2211 Allenwood Road INSURER E: Wall Twp NJ 07719 INSURER F COVERAGES CERTIFICATE NUMBER:2015-16 Liab Master REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR ADDL SUER POLICY EFF POLICY EXP TYPE OF INSURANCE LTR POLICY NUMBER MIDDIYYYY) (MM/DDfYYYY1l LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 2,000,000 A CLAIMS-MADE FxIOCCUR PREMISES E ToEa aceENT amoe S 500,000 E00130000065615 11/1/2015 11/1/2016 MED EXP(Any one person) S PERSONAL B ADS INJURY S 1,000,000 GEN L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE S 2,000,000 X POLICY JEC LOC PRODUCTS-COMP/OP AGO $ 2,000,000 OTHER: Employee Benefits S 11000,000 AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 2,000,000 Ea accident A X ANY AUTO BODILY INJURY(Per Person) S ALL OWNED SCHEDULED EAGCC000065715 11/1/2015 11/1/2016 BODILY INJURY(Per accident) $ AUTOS AUTOS NON-OWNED PROPERTY DAMAGE $ HIRED AUTOS AUTOS Per accident PIP-Extended S 8,000 A UMBRELLA LIAB OCCUR ERAGC000065615 11/1/2015 11/1/2016 EACH OCCURRENCE $ 3,000,000 C X EXCESS LIAB CLAIMS-MADE AGGREGATE $ 3,000 000 DED RETENTION$ 5227985133 11/1/2015 11/1/2016 Limes x of$3,000,000 S 21,000,000 WORKERS COMPENSATION PER OTH- AND EMPLOYERS*LIABILITY YIN STATUTE ER ANY PROPRIETORIPARTNERIEXECUTIVE ❑ NIA E.L EACH ACCIDENT $ 1 000 000 OFFICEWMEMBER EXCLUDED4 A (Mandatary In NH) ENGCC000056515 11/1/2015 11/1/2016 E.L.DISEASE-EA EMPLOYEE S 1,000,000 If yes,describe under DESCRIPTION OF OPERATIONS below ELDISEASE-POLICYLIMIT $ 1,000,000 B Errors & Omissions PGIARICO201903 5/30/2015 6/30/2016 Per Occurrence $2,000,000 Pollution Liability Aggregate $2,000,000 DESCRIPTION OF OPERATIONS I LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be ettachetl if more space is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE Trinity Heating & Air, Inc. THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN 20 Patterson Brook Road ACCORDANCE WITH THE POLICY PROVISIONS. Wareham, MA 02571 AUTHORIZED REPRESENTATIVE Barbara Y.ayden/LP.H - '--� ©1988-2014 ACORD CORPORATION. All rights reserved. ACORD 26(2014/01) The ACORD name and logo are registered marks of ACORD INS025(201401) '\ The Conintitit Ivealth of Massach useli s Department of IndnslrialAccidents Ulkirkers' I Congress Street,Suite 100 Boston,AIA 02114-2017 wwlvinass.gat✓diir Compensation Insurance Affidavit:Builders•/C,anh•aetors/Eleetricimts/Plumbers. TO BE FILED WITH TITE PE2WHTPLNG AUTHORITY. Aunlicant Information Please Print Leeib Name (BusWess/OrganizalfosJlndividual): Tnn) y .Solar Address: 2211 Allenwood Road City/State/zip: Wall, NJ 07719 phone#: 732-780-3779 Are you an employer?Chick the appropria to has: Type of project(required): 1ariamsemployr,vilh 300 cmployccs(tultandrorpan-time).' 7. ❑New construction 2.❑I:.m a sole propnen ror panaershipand have no employees working for me in 8. ❑Remodeling any capacity.(No workers'comb.insurance required.] 9. ❑Demolition 3.❑1am ahomeowmer doing all work myseiC pJu workrrs'cortp,insurance requireJ.li 11.01 am a homwnmerand will he hiring contractors to conduct all work on my property. 1 will 10❑Building addition ensure that all conlroctorsenher have workers'compensaton insurance or we sole It.vElectrical repairs or additions purprictons with ao employees. 12.❑Plumbing repairs or additions 5.E]I am a general connector and I have hired the sub-contractors listed ma llre anached sheet. 1$.❑Roof repairs These sub.conuactors have employees and have workers'comp.insurances 6E]Iva smacorpoalion and its officers have exercised their right of exemption per MGL c. 14.❑Other _ 152,§I(q),and t o have no employees.[No workers'comp.insurance required.) *Any applicant that checks box 81 must also fill out the section below shaving Their workers'compensation policy information. t Homeowners who subodt(his affidavit indicating they we doing all work eid then hire outsidu conlruetnrs must submit a new a0ldavi(indicating such. lContractors that cluck this box oust anached an additional sheet showing the name of the subcontractors and stale whether or not those entities have employees. If the subcontractors have employees,(hey most provide their workeri comp.policy number. I am an employer that is provlifing workers'compensation insurancefor try ensployees. Below is the policy and jab site hifonnation. Insurance Company Name: The Dittmar Agency _ Policy#or Self-ins,Lic,#:�656.1.5 Expiration Date: 1 1/111 6 Job Site Address: 13 Pleasant Street Apt 31 City/State/Zip: Salem, MA 01970 Attach a copy ofthe workers'compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under MGL c. 152,§25A is a criminal violation punishable by a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cerU 22under the paias and peneddec of perjury that the information provided above Is true and correct. $(gnature:. AJ,Qd Pl.". Dale: 3/29/16 Phone#' Offlciai use only. Do not write In this area,to be completed by eity or town offleta. City or Town: PermitiLicense# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.Cityfrown Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: Office of Consumer Affairs ifnd{ ,Business Regutatio.n se; 10 Park Ptaza - Suite 5170 Boston, Massachusetts 02116 Home Improvement Contractor Registration Registration: 170355 Type: Supplement Card TRINITY HEATING & AIR, INC. Expiration: 1 011 2/2 01 7 GREGG-L-ACASSE 20 PATTERSON BROOK ROAD UNIT 10 WEST WAREHAM, MA 02576 Update Address and return card.Nlark reason for change. 9CA 1 '11 2JA1.95111 Address ❑ Renewal E] Employment Lost Card /"�a�annrnnl« cur.///c�'^zr�.c�at/uanC/ ue ofConsamer Affairs&Business Regalarioa License or registration valid for individul use only ME-IMPROVEMENT CONTRACTOR before the expiration date. H found return to: Rag e i : Office of Consumer Affairs and Business Regulation 9 170355 Type: 10 Park Plaza-Suite 5170 Expiration: 1 0/1 212 01 7 Supplement Card Boston,MA 02116 TRINITY HEATING&AIR,INC. GREGG LACASSE 20 PATTERSON BROOK ROAD .�,.--.-�_�__�,•--- WEV WAREHAM,MA 02576 undersecretary N 6va 'th0ut sir ature Massachusetts Department of Public Safety ® Board of Building Regulations and Standards License: CS-103631 Construction Supervisor GREGG LACASSE� 14 PINE ISLANDRo, MATTAPOISETT MA, y rJZ7 -Expiration: Commissioner 0813012017 uocuaiyn ❑nveiape iu:of rui coo� rooao One-Roof Energy's residential power purchase arwee � n x. oneroof. one sun. zero surprises. ONER®CIF' 6 N 6 R O Y Dsh ORf SOlee uocuajgn znve,ope w: or rwcoo-v ior- rou-ooeo-aroe ivn iaoao ®NERCI®F• E N E R G Y D81 ORE SOLAR OneRoof Energy's Residential Power Purchase Agreement Date: 3/19/2016 Here are the key terms of your OneRoof Energy Power Purchase Agreement System installation cost _ $0 Initial Electricity rate per kWh _ $0 . 105 Agreement term 20 years OneRoof Promises to You 7 • We insure, maintain,and repair the System (including the inverter) at no additional cost to you, as specified in the agreement. • We provide 24/7 web-enabled monitoring at no additional cost to you,as specified in the agreement. • We warranty your roof against leaks and restore your roof if the system is removed, as specified in the agreement. • The rate you pay for electricity, exclusive of taxes,will never increase by more than 2.9% per year. Homeowner's Name & Service Address Homeowner Name and Address Co-Owner Name(If Any) Susan W Engelke 13 PLEASANT ST APT S1 SALEM, MA 01970 Options for System purchase and transfer: Options at the end of the 20 year term: • If you move, you may transfer this agreement to the • You can upgrade to a new System with the latest solar purchaser of your Home, as specified In the agreement. technology under a new contract • At certain times, as specified in the agreement,you may • You may purchase the System fromOneRoof as specified in purchase the System. the agreement • These options apply during the term of our agreement and • You may renew this agreement as specified in the not beyond that term. agreement THE SYSTEM IS OWNED BY ONEROOF ENERGY, INC.AND/OR ITS AFFILIATES OR ASSIGNEES. ONEROOF ENERGY, INC.14445 Eastgate Mall Road, Suite 240, San Diego, CA 92121 i (855)697-2348 MA HOME IMPROVEMENT CONTRACTOR REGISTRATION NUMBER: 172197 2014102103 D0CUMEN7SERIALNUMBER 184413 umuaign cnvewpe iu:wruicoo-v or-vroi,-0000-arni v,o iaoaa t. Introduction. Payments due upon installation, if any,are due This Power Purchase Agreement(this "Power Purchase immediately prior to commencement of installation. Agreement" or"PPA") is the agreement between you and OneRoof Energy, Inc. (together with its successors and (c) Estimated Production. If(i)the System is shut down assigns,"OneRoof'or"we"),covering the sale to you of the for more than seven (7)full twenty-four(24)hour days power produced by the solar panel system(the"System") cumulatively during the Term because of%'our actions we will install at your home. OneRoof agrees to sell to you, (including any removal of the System at your request); and you agree to buy from OneRoof,all of the power (ii)you take some action that significantly reduces the produced by the System. The System will be installed by output of the System; (iii)you don't trim your bushes or OneRoof,or an approved third parry installer at the trees to their appearance when you signed this PPA to address you listed above(the"Property'or your"Home.") avoid foliage growth from shading the System; or(iv) OneRoof provides you with a OneRoof Energy Limited your System is not reporting production to OneRoof Warranty(the`Limited Warranty"). The Limited (e.g.you have disconnected or made inoperable your Warranty is attached as Exhibit 2. By signing this Power monitoring system),then OneRoof will reasonably Purchase Agreement you represent that you are either a estimate the amount of power that would have been citizen of the United States or not exempt from paying delivered to you during such System or reporting Federal income taxes. If you have any questions regarding outages or reduced production periods ("Estimated this Power Purchase Agreement,please ask your OneRoof Production")and shall consider Estimated Production sales consultant. as actual production for purposes of this paragraph. In the first year of the Term, Estimated Production will be 2. Term. based on our production projections. After the first OneRoof agrees to sell you the power generated by the year of the Term, Estimated Production will be based on System for twenty(20)years(240 months),plus,if the historical production for that month in the prior year. If Interconnection Date is not on the tilt day of your billing we bill you for Estimated Production because your cycle,the number of days prior to the start of you initial System is not reporting production to OneRoof,and we billing date. We refer to this period of time as the"Term." subsequently determine that we have either The Term begins on the Interconnection Date. The overestimated or underestimated the actual production, "Interconnection Date"is the date that the System is then we will adjust the next bill downward(to refund turned on and generating power. OneRoof will notify you overbilling)or upward(to make up for lost billing). You when your System is ready to be turned on. will not be charged for Estimated Production when the System is not producing electricity due to OneRoofs 3. Intentionally Left Blank. fault,or if it's due to grid failure or power outages caused by someone other than you. ONEROOF DOES 4. Power Purchase Agreement Payments :Amounts. NOT WARRANT OR GUARANTEE THE AMOUNT OF (a) Power Price. You are purchasing all of the power ENERGY PRODUCED BY THE SYSTEM FOR ANY the System produces. During the first year of the PERIOD OR THAT YOU WILL REALIZE ANY term,the purchase price is $0.105 per kWh. After SAVINGS AS COMPARED TO THE COSTS OF the first year,the price per kWh will increase by PURCHASING YOUR POWER FROM THE LOCAL 2.9%of the previous year's price.There are no UTILITY. installation costs to you. g. Power Purchase Agreement Obligations. (b) Payments.Your monthly payments will be the product of(A)the price per kWh multiplied by(B) (a)System, Home and Property Maintenance the actual kWh output for the calendar month ("Monthly Payments"). Invoices for Monthly You agree to: Payments will be mailed or emailed at OneRoofs (i) only have the System repaired pursuant to the sole discretion no later than ten (1o) days alter the Limited Warranty and reasonably cooperate when end of a calendar month. If you are paying your repairs are being made; invoice by automatic debit from your checking or (ii) keep trees,bushes and hedges trimmed so that the savings account(ACH)we will debit your bank System receives as much sunlight as it did when account on or about the rst day of the next month OneRoof installed it; following invoice(e.g.January invoices are sent in (iii) not modify your Home in a way that shades the early February and debited on or about March 1). System; Monthly Payments will change as your price per (iv) be responsible for any conditions at your Home that kWh changes over the Term of this PPA and as affect the installation(e.g.,blocking access to the System production varies (e.g.,summer has higher roof,or removing a tree that is in the way,or prior production).You will have regular access to the work you have done on your Home that was not System's production via your OneRoof online permitted); account. (v) not remove any markings or identification tags on the System; OneRoof Energy Residential Power Purchase Agreement- 2 2014102103 DOCUMENT SERIAL NUMBER 184411 u000aiyn urveiope iu: i vro Ieoeo (vi) As set forth in 5(g)(i),permit OneRoof, its designees, do not make automatic Monthly Payments through or its financing parties, after we give you reasonable your checking or savingsaccount; notice, to inspect the System for proper operation as (ii) Returned Check Fee: $25 (or such lower amount as we reasonably determine necessary; required by law)for any check or withdrawal light that (vii) use the System primarily for personal,family or is returned or refused by your bank; and household purposes,but not to heat a swimming pool; (iii)Late Payments: are charged a 5%late fee(or the (viii) not do anything, permit or allow to exist any maximum late fee allowed by law,if less than 5%) and condition or circumstance that would cause the may accrue interest at the lesser of twelve percent System not to operate as intended at the Property; (12%) annually or the maximum percentage allowable (ix) notify OneRoof if you think the System is damaged or by applicable law. appears unsafe; if any part of the System is stolen; and prior to changing your power supplier; (e)Taxes (x) have everyone who has an ownership interest and Your OneRoof electricity rate of$o.lo5 per kWh is requisite authority in your Home sign this Power composed of an electricity rate of$o.ro5 plus current Purchase Agreement; taxes of$o.00.You agree to pay any changes in the (xi) return any documents we send you for signature(like applicable taxes related to this PPA. Thus, if tax rates incentive claim forms)within seven(7)days of change, the amount you pay will change to reflect this rate receiving them; and change.If this PPA contains a purchase option,you agree to pay any applicable tax on the purchase price for the (b) System Construction,Repair, Insurance and System. You also agree to pay as invoiced any applicable OneRoofs obligations: taxes on the System that your local jurisdiction may levy. OneRoof agrees to: (f) No Alterations (i) schedule the installation of the System at a mutually You agree that you will not make any modifications, convenient date and time; improvements, revisions or additions to the System or (ii) construct the System according to written plans you take any other action that could void the Limited review; Warranty on the System without OneRoofs prior written (ii) provide you with a monitor to accurately measure the consent. If you make any modifications, improvements, amount of power the System delivers to you; revisions or additions to the System,they will become part (iv) notify you if the System design has to be materially of the System and shall be OneRoofs property. changed so that you can review any such changes; (v) clean up after ourselves during the construction of the (g) Access to the System System; (i) You grant to OneRoof, its designees, its financing (vi) insure the System against all damage or loss unless parties and their employees, agents and contractors (A)that damage or loss is caused by your gross the right to reasonably access all of the Property as negligence: or(B)you intentionally damage the necessary for the purposes of(A) installing, System. Upon damage or destruction to the System, constructing,operating,maintaining,owning, you will not be entitled to receive or retain any repairing, removing and replacing the System or insurance proceeds. In cases where we bear the risk of making any additions to the System or installing loss,our sole obligation to you will be to repair or complementary technologies on or about the location replace the System to the extent required by the of the System; (B)enforcing OneRoof or its financing Limited Warranty; and parties'rights as to this Power Purchase Agreement (vii) repair the System pursuant to the Limited Warranty and the System; (C) installing,using and maintaining and reasonably cooperate with you when scheduling electric lines and inverters and meters, necessary to repairs. interconnect the System to your electric system at the Property and/or to the utility's electric distribution (c) Home Renovations or Repairs system; or(D)taking any other action reasonably If you want to make any repairs or improvements to the necessary in connection with installing, constructing, Property that could interfere with the System(such as operating,maintaining, owning,repairing, removing repairing the roof where the System is located),you may and replacing the System.This access right shall only have the System removed and replaced pursuant to continue for up to ninety(go) days after this Power the Limited Warranty. Purchase.Agreement expires to provide OneRoof with time to remove the System at the end of the (d)Automatic Payment, Late Charges Power Purchase Agreement. OneRoof shall provide In addition to the other amounts you agree to pay in this you with reasonable notice of its need to access the Power Purchase Agreement,you agree to pay the Property whenever commercially reasonable. following: (i) Automatic Payment Discount: All prices include a (ii) During the time that OneRoof has access rights you $7.50 monthly discount for using automatic payment. shall ensure that its access rights are preserved and You will not receive a $7.50 monthly discount if you shall not interfere with or permit any third party to OneRoof Energy Residential Power Purchase Agreement-3 2014102103 DOCUMENT SERIAL NUMBER 184413 vocuaign envelope iu:oe rut Lon-ti nor-tiro..-0000-orai i.vn ieaas interfere with such rights or access. You agree that 6. Conditions Prior to Installation of the System: the System is not a fixture,but OneRoof has the right Change Orders. to file any UCC-i financing statement,or fixture filing (a) OneRoof Is obligation to install the System and sell that confirms its interest in the System.Neither this you the power it produces is conditioned on the PPA nor any UCC-1 financing statement we may file in following items having been completed to its connection with this PPA constitutes or imposes a reasonable satisfaction: consensual lien on your Home or Property. (i) completion of(A) the engineering site audit(a thorough physical inspection of the Property, (h) Indemnity including,if applicable,geotechnical work), (B) To the fullest extent permitted by law,you shall indemnify, the final System design, and(C) real estate due defend,protect, save and hold harmless OneRoof,its diligence to confirm the suitability of the Property employees, officers. directors, agents,financing partners, for the construction, installation and operation of successors and assigns from any and all third party claims, the System; actions,costs, expenses(including reasonable attorneys' (ii) approval of this Power Purchase Agreement by fees and expenses),damages,liabilities,penalties,losses, OneRoofs financing parties; obligations,injuries, demands and liens of any kind or (iii) your meeting the applicable credit criteria; nature arising out of, connected with,relating to or (iv)confirmation of rebate,tax credit and renewable resulting from your negligence or willful misconduct; energy credit payment availability in the amount provided,that nothing herein shall require you to used to calculate the Monthly Payments set forth indemnify OneRoof for its own negligence or willful in this Power Purchase Agreement; misconduct.The provisions of this paragraph shall survive (v)confirmation that OneRoof will obtain all termination or expiration of this Power Purchase applicable benefits referred to in Section 9; Agreement. (vi)receipt of all necessary zoning,land use and building permits; and (i) Payments (vii)completion of any renovations,improvements or SUBJECT TO SECTION 4(b)ABOVE,YOU AGREE THAT changes at your Home or on the Property which THE OBLIGATION TO PAY ALL PAYMENTS AND ALL have been agreed upon in writing(e.g., removal of OTHER AMOUNTS DUE UNDER THIS PPA SHALL BE, a tree or necessary roof repairs to enable us or our ABSOLUTE AND UNCONDITIONAL UNDER ALL designee to safely install the System). CIRCUMSTANCES AND SHALL NOT BE SUBJECT TO OneRoof may terminate this Power Purchase Agreement ANY ABATEMENT, DEFENSE,COUNTERCLAIM, without liability if,in its reasonable judgment, any of the SETOFF, RECOUPMENT OR REDUCTION FOR ANY above listed conditions (i)through (vii)will not be REASON WHATSOEVER, IT BEING THE EXPRESS satisfied for reasons beyond its reasonable control. Once INTENT OF THE PARTIES THAT ALL AMOUNTS OneRoof or its approved third-party installer starts PAYABLE BY YOU HEREUNDER SHALL BE,AND installation,however,it may not terminate this Power CONTINUE TO BE, PAYABLE IN ALL EVENTS Purchase Agreement for your failure to satisfy conditions INCLUDING BY YOUR HEIRS AND ESTATE AND, (i)through(vii) above. EXCEPT AS SET FORTH BELOW IN SECTIONS 6, 22 AND 23,YOU HEREBY WAIVE ALL RIGHTS YOU MAY (b) Amendments. HAVE TO REJECT OR CANCEL THIS PPA,TO REVOKE The System's production will be documented in an ACCEPTANCE OF THE SYSTEM,OR TO GRANT A amendment to this PPA. You authorize OneRoof to make SECURITY INTEREST IN THE SYSTEM. corrections to the utility paperwork to conform to this PPA or any amendments to this PPA we both sign.In the (j) Credit Check event that you reject the amendment or otherwise fail to OneRoof may have prescreened your credit. Prescreening sign and deliver it for seven days after receiving it,either of credit does not impact your credit score.You can choose you or OneRoof may terminate this PPA within the to stop receiving"prescreened"offers of credit from this fourteen-day period beginning on the date you received and other companies by calling toll-free, 1-888-5- the proposed amendment. OPTOUT(1-888-567-8688).You authorize OneRoof, or its designee,to obtain your credit report now and in the 7. Warranty. future, check your credit and employment history,answer YOU UNDERSTAND THAT THE SYSTEM IS questions others may ask regarding your credit and share WARRANTED SOLELY UNDER THE LIMITED your credit information with OneRoofs financing WARRANTY ATTACHED AS EXHIBIT 2,AND THAT partners. You certify that all information you provide to us THERE ARE NO OTHER REPRESENTATIONS OR in connection with checking your credit will be true and WARRANTIES, EXPRESS OR IMPLIED,AS TO THE understand that this information must be updated upon MERCHANTABILITY, FITNESS FOR ANY PURPOSE, request if your financial condition changes. CONDITION, DESIGN,CAPACITY, SUITABILITY OR PERFORMANCE OF THE SYSTEM OR ITS INSTALLATION. OneRoof Energy Residential Power Purchase Agreement-4 2014202103 DOCUMENT SERIAL NUMBER 184413 uocuatgn❑nveiope w: o r r w co0-4 Iar-4r oa,-ooaororn t van I aoyo 8. Transfer. (ii) at any time after the five(5)year anniversary of the OneRoof will assign this PPA to one of its financing beginning of the Term, when you sell your Home; and partners. You agree that OneRoof may assign,sell or (iii)if OneRoof ever ceases its operations and fails to transfer the Svstem and this Power Purchase Agreement, provide for a substitute provider. or any part of this Power Purchase Agreement or the In each of(i), (ii)and (iii) above,the price you will pay for exhibits,without your consent. This assignment does not the System will the greater of(a) the amount set forth in change OneRoofs obligation to maintain and repair your the Agreement Amendment for the year in which the System as set forth in the Warranty.Any assignment of purchase is requested and(b)the System's fair market OneRoofs rights and/or obligations under this value as determined by an independent appraiser. Agreement shall not result in any change to vour rights OneRoofs maintenance and repair obligations under the and obligations under this Agreement. Limited Warranty(Exhibit z)will end when you purchase the System. q. Ownership of the System: Tax Credits and Rebates. ii. Renewal. You agree that the System is OneRoofs personal property If you are in compliance with your PPA,you have the under the Uniform Commercial Code. You understand option to renew your PPA in five (5)year renewal and agree that this PPA is not a contract to sell or lease the periods. We will send you renewal forms three(3) System to you. OneRoof owns the System for all months prior to the expiration of the T erm,which forms purposes, including any data generated from the System. shall set forth the new Monthly Payments due under the You shall at all times keep the System free and clear of all renewal PPA. If you want to renew,complete the renewal liens,claims,levies and legal processes not created by forms and return them to us at least one (i) month prior OneRoof, and shall at your expense protect and defend to the end of the PPA. In the event that you notify us in OneRoof against the same. writing at least one(1)month prior to the end of the PPA that you do not want to renew this PPA,this PPA shall You understand and agree that any and all tax credits, expire by its terns on the termination date. If you don't incentives,renewable energy credits,green tags,carbon send us anything in writing after we send you the renewal offset credits,utility rebates,Commonwealth Solar or forms,then this PPA shall renew for an additional six(6) other state or city rebates, or any other non-power month term at ten percent(1o%)less than the then- attributes of the system("Additional Attributes")are the current average rate charged by your local utility and property of and for the benefit of OneRoof,usable at its shall continue to renew for six(6) month terms at the sole discretion. OneRoof shall have the exclusive right to same rate as vour first renewal until(i)you give us notice enjoy and use all such benefits,whether such benefits at least thirty(3o)days prior to a renewal term that you exist now or in the future. You agree to refrain from do not wish to renew; or(ii) we send you a notice entering into any agreement with your utility that would terminating the PPA. entitle your utility to claim any Additional Attributes. You agree to reasonably cooperate with OneRoof so that it 12. Selling Your Home. may claim any Additional Attributes from the system.This (a)If you sell your Home you can: may include to the extent allowable by law,entering into (i) Transfer this Power Purchase Agreement and net metering agreements,interconnection agreements, the Monthly Payments and tiling renewable energy/carbon offset credit If the person buying your Home meets OneRoofs registrations and/or applications for rebates from the credit requirements,then where permitted by the local federal, state or local government or a local utility and utility,the person buying your Home can sign a transfer giving the resulting Additional Attributes to OneRoof. If agreement assuming all of your rights and obligations you receive directly any such Additional Attributes or under this Power Purchase Agreement. payment therefor as a result of an application submitted (ii)Prepay this Power Purchase Agreement and by you or by OneRoof,then you will promptly notify Transfer only the Use of the System OneRoof and pay over or assign to OneRoof the value of You can prepay this Power Purchase Agreement in full the Additional Attributes. by paying OneRoof the expected remaining payments (estimated future production during the rest of the io. Purchasing the System. Term multiplied by the average kWh rate during the In addition to having the option to purchase the System at rest of the Term)at a five percent(5%)discount rate. the end of the Term,you have the option to purchase the The person buying your Home will only need to sign a System prior to the end of the Term as detailed below. To transfer agreement to assume your rights and non- exercise this option you must be in good standing under Monthly Payment obligations under this PPA. The this Power Purchase Agreement and you need to give us at System stays at your Home,the person buying your least one(1)month's,but not more than three(3)months' Home does not make any Monthly Payments and has prior written notice. You can purchase this System: only to comply with the non-Monthly Payment portions (i) on the five(5)year anniversary of the beginning of the of this PPA. Term and every annual anniversary after the five(5) (iii) Purchase the System year anniversary; and At any time after the five(5)year anniversary of the OneRoof Energy Residential Power Purchase Agreement-5 2014102103 DOCUMENT SERIAL NUMBER 184413 uocuaiyn cnveiope iu:or rutcoo�iar-yrou-Donn-aror ivo iv"J beginning of the Term,you can purchase the System have undertaken in this PPA (which includes doing _ under Section to of this PPA something you have agreed not to do,like alter the (b)You agree to give OneRoof at least fifteen(15)days but System)and such failure continues for a period of not more than three(3) months prior written notice if fourteen(14)days after written notice; you want someone to assume your PPA obligations. In (c) you or your guarantor have provided any false or connection with this assumption,you,your approved misleading financial or other information to obtain buyer and OneRoof shall execute a written transfer of this Power Purchase Agreement; this PPA. (d) you assign,transfer, encumber,sublet or sell this PPA (c) If you sell your Home and do not comply with any of the or any part of the System without OneRoofs prior options in subsection (a)above,you will be in default written consent;or under this Power Purchase Agreement. Section 12(a) (e) you or any guarantor makes an assignment for the includes a Home sale by your estate or heirs. benefit of creditors,admits in writing its insolvency, (d) EXCEPT AS SET FORTH IN THIS SECTION,YOU WILL files or there is filed against you or it a voluntary NOT ASSIGN, SELL, PLEDGE OR IN ANY OTHER WAY petition in bankruptcy, is adjudicated bankrupt or TRANSFER YOUR INTEREST IN THIS PPA WITHOUT insolvent or undertakes or experiences any OUR PRIOR WRITTEN CONSENT,WHICH SHALL substantially similar activity. NOT BE UNREASONABLY WITHHELD. 16. Remedies in Case of Default. 13. Loss or Damage. If this Power Purchase Agreement is in default,we may (a) Unless you are grossly negligent or you intentionally take any one or more of the following actions. If the law damage the System, OneRoof will bear all of the risk of requires us to do so,we will give you notice and wait any loss,damage,theft,destruction or similar occurrence period of time required before taking any of these actions. to any or all of the System. Except as expressly We may: provided in this PPA,no loss, damage,theft or (a) terminate this PPA; destruction will excuse you from your obligations (b) take any reasonable action to correct your default or under this PPA,including Monthly Payments. to prevent our loss; any amount we pay will be added (b) If there is loss, damage,theft,destruction or a similar to the amount you owe us and will be immediately occurrence affecting the System, and you are not in due; default of this PPA,you shall continue to timely make (c) require you, at your expense,to return the System or all Monthly Payments and pay all other amounts due make it available to us in a reasonable manner; under the PPA and,cooperate with OneRoof, at (d) proceed,by appropriate court action, to enforce Onelloofs sole cost and expense,to have the System performance of this PPA and to recover damages for repaired pursuant to the Limited Warranty. your breach; (e) disconnect,turn off or take back the System by legal 14. Limitation of Liability. process or self-help; (a)No Consequential Damages (f) report such non-operational status of the System to ONEROOF'S LIABILITY TO YOU UNDER THIS your utility,informing them that you are no longer POWER PURCHASE AGREEMENT SHALL BE net metering; LIMITED TO DIRECT,ACTUAI.DAMAGES ONLY. (g) charge you a reasonable reconnection fee for YOU AGREE THAT IN NO EVENT SHALL EITHER reconnecting the System to your utility or turning PARTY-BE LIABLE TO THE OTHER FOR your System back on after we disconnect or turn off CONSEQUENTIAL,INCIDENTAL,PUNITIVE, the System due to your default; EXEMPLARY,SPECIAL OR INDIRECT DAMAGES. (h) recover from you(i)a payment equal to the purchase (b)Actual Damages price as set forth in this agreement plus(ii)all taxes, EXCEPT FOR CLAIMS UNDER SECTION 5(Ho, late charges,penalties, interest and all or any other NEITHER PARTY S LIABILITY TO THE OTHER WILL sums then accrued or due and owing; or EXCEED AN AMOUNT EQUAL TO THE MAXIMUM (i) use any other remedy available to us in this PPA or by AMOUNT THAT COULD BE PAYABLE BY YOU law. UNDER SECTION 16(H) . DAMAGES TO YOUR HOME, BELONGINGS OR PROPERTY RESULTING We may submit to credit reporting agencies(credit FROM THE INSTALLATION OR OPERATION OF bureaus)negative credit reports that would be reflected THE SYSTEM ARE COVERED IN SUCTION 6(C)OF on your credit record if you do not pay any amounts due THE LIMITED WARRANTY. under this PPA as required. 15. Default. You agree to repay as for any reasonable amounts we pay You will be in default under this Power Purchase to correct or cover your default.You also agree to Agreement if any one of the following occurs: reimburse us for any costs and expenses we incur relating (a) you fail to make any payment when it is due and such to the System's return resulting from early termination. failure continues for a period of ten(ro)days; By choosing any one or more of these remedies, OncRoof (b) you fail to perform any material obligation that you does not give up its right to use another remedy. By OneRoof Energy Residential Power Purchase Agreement-6 2014102103 DOCUMENT SERIAL NUMBER 184413 uucuaign cnveope iu:or iro iaoyo deciding not to use any remedy should this Power If you initiate the arbitration,you will be required Wpay Purchase Agreement be in default, OneRoof does not give the first$125 of any tiling fee. We will pay any filing fees up our right to use that remedy in case of a subsequent in excess of$125 and we will pay all of the arbitration fees default. and costs. If we initiate the arbitration,we will pay all of the filing fees and all of the arbitration fees and costs. We 17. System Removal. will each bear all of our own attorneys fees and costs At the end of the Term or the termination of this PPA,if except that you are entitled to recover your attorney's fees you have not renewed this PPA or exercised your purchase and costs if you prevail in the arbitration and the award option (if any), then OneRoof shall have the right to you receive from the arbitrator is higher than OncRoofs remove the System if we notify you within ninety(go) last written settlement offer. When determining whether days of the end of the Term or termination of this PPA. your award is higher than OneRoofs last written You agree to cooperate with us to schedule a convenient settlement offer your attorney''s fees and costs will not be time for OneRoof to remove the System from your Home included. at no cost to you, if OneRoof elects to so remove the System. If OneRoof does not elect to remove the System, Only Disputes involving you and OneRoof may be title to the System shall be transferred to you. addressed in the arbitration. Disputes must be brought in the name of an individual person or entity and must 18. Applicable Law, Arbitration. proceed on an individual(non-class, non-representative) THIS SECTION 18 CONTAINS AN ARBPI'RATION basis.The arbitrator will not award relief for or against PROVISION. BY INITIALING SECTION 18 WHERE anyone who is not a party. If either of us arbitrates a INDICATED BELOW,YOU AND ONEROOF MUTUALLY Dispute, neither of us,nor any other person,may pursue AGREE IN ADVANCE TO SUBMIT CERTAIN DISPUTES the Dispute in arbitration as a class action,class IDENTIFIED IN THIS SECTION 18 TO A PRIVATE arbitration,private attorney general action or other ARBITRATION SERVICE WHICH HAS BEEN representative action, nor may any such Dispute be APPROVED BY THE DIRECTOR OF THE EXECUTIVE pursued on your or our behalf in any litigation in any OFFICE OF CONSUMER AFFAIRS AND BUSINESS court.Claims regarding any Dispute and remedies sought REGULATIONS AS PROVIDED IN CHAPTER 142A OF as part of a class action,class arbitration,private attorney THE MASSACHUSETTS GENERAL.LAWS. PLEASE general or other representative action are subject to READ THIS SECTION CAREFULLY.ARBITRATION arbitration on an individual (non-class, non- REPLACES THE RIGHT TO GO TO COURT, representative)basis,and the arbitrator may award relief INCLUDING THE RIGHT TO A JURYAND THE RIGHT only on an individual (non-class,non-representative) TO PARTICIPATE IN A CLASS ACTION OR SIMILAR basis.This means that the arbitration may not address PROCEEDING. IN ARBITRATION,A DISPUTE IS disputes involving other persons with disputes similar to RESOLVED BY AN ARBITRATOR INSTEAD OF A the Disputes between you and OneRoof. JUDGE OR JURY. The arbitrator shall have the authority to award any legal The laws of the state where your Home is located shall or equitable remedy or relief that a court could order or govern this PPA without giving effect to conflict of laws grant under this agreement.The arbitrator, however,is principles. We agree that any dispute,claim or not authorized to change or alter the terms of this disagreement between us(a "Dispute")shall be resolved agreement or to make any award that would extend to any exclusively by arbitration. transaction other than yours.All statutes of limitations that are applicable to any dispute shall apply to any The arbitration, including the selecting of the arbitrator, arbitration between us. The arbitrator will issue a will be administered by JAMS,under its Streamlined decision or award in writing, briefly stating the essential Arbitration Rules(the"Rules")by a single neutral findings of fact and conclusions of law. arbitrator agreed on by the parties within thirty(3o) days of the commencement of the arbitration,or another BECAUSE YOU AND WE HAVE AGREED TO arbitration service approved by the Director of the ARBITRATE ALL DISPUTES,NEITHER OF US WILL Massachusetts Executive Office of Consumer Affairs and HAVE THE RIGHT TO LITIGATE THAT DISPUTE IN Business Regulation.The arbitration will be governed by COURT, OR TO HAVE A JURY TRIAL ON THAT the Federal Arbitration Act(Title q of the U.S.Code). DISPUTE,OR ENGAGE IN DISCOVERY EXCEPT AS Either party may initiate the arbitration process by filing PROVIDED FOR IN THE RULES.FURTHER,YOU WILL the necessary forms with JAMS.To learn more about NOT I-LAVE THE RIGHT TO PARTICIPATE AS A arbitration,you can call any JAMS office or review the REPRESENTATIVE OR MEMBER OF ANY CLASS materials at ww-w.jamsadr.com.The arbitration shall be PERTAINING TO ANY DISPUTE.THE ARBITRATOR'S held in the location that is most convenient to your Home. DECISION WILL BE FINAL AND BINDING ON THE If a JAMS office does not exist within 50 (fifty)miles of PARTIES AND MAY BE ENTERED AND ENFORCED IN your Home,then we will use another accredited ANY COURT HAVING JURISDICTION, EXCEPT TO arbitration provider with offices close to your Home. THE EXTENT IT IS SUBJECT TO REVIEW IN ACCORDANCE WITH APPLICABLE LAW GOVERNING OneRoof Energy Residential Power Purchase Agreement- 2014102103 DOCUMENT SERIAL NUMBER 184413 uocuaiyn❑nveiope iu:or ru i eoow i ar-wroi.-aoao-orn r i ao i aoyj ARBITRATION AWARDS. OTHER RIGHTS THAT YOU OR WE WOULD HAVE IN COURT MAY ALSO NOT BF. AVAILABLE IN ARBITRATION. ONEROOF AND CUSTOMER ACKNOWLEDGE AND AGREE THAT THEY HAVE READ AND UNDERSTAND THE PROVISIONS OF THIS SECTION 19 AND BY THEIR INITI.ALS BELOW AGREE TO BE BOUND BY ITS TERMS. 1571"Customer's Initials Date 3/19/2016 OncRoofs Initials Date 19. Waiver. Any delay or failure of a parry to enforce any of the provisions of this PPA,including but not limited to any remedies listed in this PPA, or to require performance by the other party of any of the provisions of this PPA,shall not be construed to(i)be a waiver of such provisions or a party's right to enforce that provision;or(ii)affect the validity of this PPA. 2o. Notices. All notices under this PPA shall be in writing and shall be by personal delivery,facsimile transmission, electronic mail,overnight courier,or certified or registered mail, return receipt requested. 21. Entire Agreement: Changes. This PPA contains the parties'entire agreement regarding the sale and purchase of power generated by the System. There are no other agreements regarding this PPA, either written or oral. Any change to this PPA must be in writing and signed by both parties. If any portion of this PPA is determined to be unenforceable,the remaining provisions shall be enforced in accordance with their terms or shall be interpreted or re- written so as to make them enforceable. 22. NOTICE OF RIGHT TO CANCEL. YOU MAY CANCEL THIS CONTRACT AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE YOU SIGN THIS CONTRACT. SEE EXHIBIT t,THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. 23. ADDITIONAL RIGHTS TO CANCEL. IN ADDITION TO ANY RIGHTS YOU MAY HAVE TO CANCEL THIS PPA UNDER SECTION 22, UNLESS INSTALLATION OF YOUR SYSTEM HAS AI READY COMMENCED,YOU 1%,1AY ALSO CANCEL THIS PPA AT NO COST AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER YOU SIGN THE FIRST AMENDMENT TO THIS PPA DETAILING YOUR ESTIMATED PRODUCTION. One Roof Energy Residential Power Purchase Agreement-8 2014102103 DOCUMENT SERIAL NUMBER 184423 uocuaiyn o iveiope tu:or ru r cao-•t i nr-vroi,-neon-orn i uio i eaa� I have read this Power Purchase Agreement and the Exhibits in ONEROOP ENERGY,INC. their entirety and I acknowledge that I have received a complete copy of this Power Purchase Agreement. Power Purchase Agreement Susan W dtliVigned by Signature: PBy: Fd1A9A0i11]n49F Title: Date: 3/19/2016 Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do nor sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: OneRoof Energy Residential Power Purchase Agreement-9 2014102103 DOCUMENT SERIAL NUMBER 194413 UOcu Jlgn GnVeIONe IU:O(rl I cJO-4 I IAD I&O&J EXHIBIT I (ONEROOF ENERGY, INC. COPY) NOTICE OF CANCELLATION STATUTORILY-REQUIRED LANGUAGE M.G.L. c.93 §48 Notice of Cancellation Date of Transaction: 3/19/2016 You may CANCEL this transaction, without any penalty or obligation,within THREE BUSINESS DAYS from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN BUSINESS DAYS following receipt by the seller (OneRoof Energy, Inc. ("Oneltoof'))of your cancellation notice, and any security interest arising out of the transaction will be canceled. If you cancel, you must make available to the seller(OncRoof)at your residence,in substantially as good condition as when received, any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the seller(OncRoof)regarding the return shipment of the goods at the seller's (OneRoofs) expense and risk. If you do make the goods available to the seller(OneRoof) and the seller(OneRoof)does not pick them up within 20 days of the date of your notice of cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller(OneRoof), or if you agree to return the goods to the seller(OneRoof) and fail to do so,then you remain liable for performance of all obligations under the contract. To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice, or any other written notice, or send a telegram to OneRoof Energy, Inc., 4445 Eastgate Mall Road, Suite 240,San Diego,CA 92121 NOT LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS from the date you signed the Power Purchase Agreement. I,SUSAN W ENGELKE , HEREBY CANCEL THIS TRANSACTION on (Date). Owner's Signature: Co-Owner's Signature: OneRoof Energy Residential Power Purchase Agreement-io 2014102103 DOCUMENT SERIAL NUMBER 194413 uocoaign envelope iu:o r rw eoo-v wr-wroi,-onoo-oro �n rooaa EXHIBIT i (CUSTOMER COPY) NOTICE OF CANCELLATION STATUTORILY-REQUIRED LANGUAGE M.G.L. c.93 §48 Notice of Cancellation Date of Transaction: 3/19/2016 You may CANCEL this transaction,without any penalty or obligation,within THREE BUSINESS DAYS from the above date. If you cancel, any property traded in, any payments made by you under the contract or sale and any negotiable instrument executed by you will be returned within TEN BUSINESS DAYS following receipt by the seller (OneRoof Energy, Inc. ("OneRoof'))of your cancellation notice, and any security interest arising out of the transaction will he canceled. If you cancel,you must make available to the seller(OneRoof) at your residence,in substantially as good condition as when received, any goods delivered to you under this contract or sale, or you may, if you wish, comply with the instructions of the seller(OneRoof)regarding the return shipment of the goods at the seller's (OneRoofs)expense and risk. If you do make the goods available to the seller (OneRoof) and the seller(OneRoof) does not pick them up within 20 days of the date of your notice of cancellation,you may retain or dispose of the goods without any further obligation. If you fail to make the goods available to the seller(OncRoof), or if you agree to return the goods to the seller (OncRoof)and fail to do so,then you remain liable for performance of all obligations under the contract. To cancel this transaction, mail or deliver a signed and dated copy of this cancellation notice, or any other written notice, or send a telegram to OneRoof Energy,Inc., 4445 Eastgate Mall Road, Suite 240, San Diego,CA 92121 NOT LATER THAN MIDNIGHT of the date that is THREE BUSINESS DAYS from the date you signed the Power Purchase Agreement. I, SUSAN W ENGELKE , HEREBY CANCEL THIS TRANSACTION on (Date). Owner's Signature: Co-Owner's Signature: OneRoof Energy Residential Power Purchase Agreement-11 201410210E DOCUMENT SERIAL NUMBER 184413 vocuaign Cnveiope 1U. or rue eoo-a iar-vro�,-nnoo-oroi irn i aaao EXHIBIT 2 PERFORMANCE GUARANTEE AND LIMITED WARRANTY 1. INTRODUCTION This Performance Guarantee and Limited Warranty(this "Limited Warranh")is OneRoofs agreement to provide you warranties on the System you are hosting pursuant to our PPA. The System will be professionally installed by OneRoof(or an approved third-party installer)at the address you listed in the PPA.We will refer to the installation location as your "Property"or your"Home." This Limited Warranty begins when we(or our designee) start installing the System at your Home. 2. LIMITED WARRANTIES (a) Limited Warranties OneRoof warrants the System as follows: (i) System Warranty During the entire Power Purchase Agreement Term, under normal use and service conditions,the System will be free from defects in workmanship or defects in,or a breakdown of,materials or components(the "System Warranty"); (ii) Roof Warranty When we(or our designee) penetrate your roof during a System installation we warrant the sealing of the roof penetrations we make to mount the Solar System and the fleshings installed by us with such penetrations. This roof warranty will run the longer of(A) one(n)year following the completion of the System installation; and(B) the least of the length of anv existing installation warranty, manufacturer warranty,or new home builder performance standard for your roof(the"Roof Warranty Period'); and (iii) Repair Promise During the entire Power Purchase Agreement Term, OncRoof will honor the Svstem Warranty and will repair or replace any defective part,material or component or correct any defective workmanship,at no cost or expense to you (including all labor costs),when you submit a valid claim to us under this Limited Warranty. If we damage your Home,your belongings or your Property we will repair the damage we cause or pay you for the damage we cause as described in Section 6. OneRoof may use new or reconditioned parts when malting repairs or replacements. OneRoof may also,at no additional cost to you,upgrade or add to any part of the System to ensure that it performs according to the guarantees set forth in this Limited Warranty. Cosmetic repairs that do not involve safety or performance shall be made at OneRoofs discretion. (b) Warranty Length (i) The warranties in Sections 2(a)(i)and 2(a)(iii) above will start when we (or our designee)begin installing the System at your Home and continue through the entire Power Purchase Agreement Term but never less than ten (1o)years.Thus,for as long as you host the System from Onel3oof under a PPA,you will have a System Warranty and our Repair Promise. (ii) The Roof Warranty Period may be shorter than the System Warranty,as described in Section 2(a)(ii) above. (iii) If you have assumed an existing PPA,or purchased the System during the Term of your PPA,then this Limited Warranty will cover you for the remaining balance of the existing PPA Term. (c) Performance Warranties and Guarantee (i) Performance Guarantee OneRoof guarantees that during the Power Purchase Agreement Term the System will operate within manufacturer's specifications and if it does not that OneRoof will repair or replace any defective part or otherwise restore System performance. (ii) Monitoring System During the Power Purchase Agreement Term,we will provide you with a Monitoring System at no additional cost OneRoof Energy Residential Power Purchase Agreement- r2 20 1 110210 3 DOCUMENT SERIAL NUMBER 184413 uocuaign enveioUe iu. otrurcoo-4 arwroi,-onao-orar iNo iaoao to you. The monitoring system captures power generation data over a cellular network from a System Monitor located on site. You will be able to view your historical power generation on OneRoofs Homeowner Portal. OneRoof will monitor you system's performance and if the System is not operating within normal ranges,we will remedy any material issues. (d) Maintenance and Operation (i) General When the System is installed,OneRoof will provide you with a System Operation Guide.This Guide provides you with System operation instructions, answers to frequently asked questions,troubleshooting tips and service information. OneRoof will perform all required System maintenance. In addition, this Agreement contains disclosures required by Massachusetts law, including without limitation the Home Improvement Contract Disclosures set forth on Exhibit 3 attached hereto (e) Making a Claim; Transferring this Warranty (i) Claims Process You can make a claim by: A. emailing us at the email address in Section 7 below;or B. writing us a letter and sending it overnight certified mail. (ii) Transferable Limited Warranty OneRoof will accept and honor any valid and properly submitted Warranty claim made during any Term by any person who either purchases the System from you or to whom you properly transfer the PPA. (f) Exclusions and Disclaimer The limited warranties and guarantee provided in this Limited Warranty do not apply to any lost power production or any repair, replacement or correction required due to the following: (i) someone other than OneRoof or its approved service providers installed, removed, re-installed or repaired the System; (ii) destruction or damage to the System or its ability to safely produce power not caused by OneRoof or its approved service providers while servicing the System(e.g., if a tree falls on the System we will replace the System per the Power Purchase Agreement,but we will not repay you for power it did not produce); (iii) your failure to perform,or breach of,your obligations under the Power Purchase Agreement(e.g.,you modify or alter the System); (iv) your breach of this Limited Warranty,including your being unavailable to provide access or assistance to us in diagnosing or repairing a problem; (v) any Force Majeure Event(as defined below); (vi) shading from foliage that is new growth or is not kept trimmed to its appearance on the date the System was installed; (vii) any system failure or lost production not caused by a System defect(e.g.,the System is not producing power because it has been removed to make roof repairs or you have required us to locate the inverter in a non-shaded area); and (viii) theft of the System(e.g.,if the System is stolen we will replace the System per the Power Purchase Agreement,but we will not repay you for the power it did not produce). This Limited Warranty gives you specific rights,and you may also have other rights which vary from state to state.This Limited Warranty does not warrant any specific electrical performance of the System other than that described above. THE LIMITED WARRANTIES DESCRIBED IN SECTIONS 2(a) and(c)ABOVE ARE THE ONLY EXPRESS WARRANTIES MADE BY ONEROOF WITH RESPECT TO THE SYSTEM. ONEROOF HEREBY DISCLAIMS,AND ANY BENEFICIARY OF THIS Lim rrED WARRANTY HEREBY WA1VL'S,ANY WARRANTY WITH RESPECT TO ANY COST SAVINGS FROM USING TILL' SYSTEM. OneRoof Energy Residential Power Purchase Agreement- 13 2014102103 DOCUMENTSERIAL NUMBER 194413 uocuaign onveiope w:orrw too-4 iarwroi.-ooco-ara, iro roaeo g. ONEROOF'S STANDARDS For the propose of this Limited Warranty the standards for our performance will be(i)normal professional standards of performance within the solar photovoltaic power generation industry in the relevant market; and(ii)Prudent Electrical Practices. `'Prudent Electrical Practices"means those practices, as changed from time to time,that meet local and state codes and are engaged in or approved by a significant portion of the solar power electrical generation industry operating in the United States to operate electric equipment lawfully and with reasonable safety, dependability,efficiency and economy. 4. SYSTEM REPAIR, RELOCATION OR REMOVAL (a) Repair. You agree that if(i)the System needs any repairs that are not the responsibility of OneRoof colder this Limited Warranty, (ii)the system needs to be removed and reinstalled to facilitate remodeling of your Home or(iii)the system is being relocated to another home you own pursuant to the Power Purchase Agreement,you will have OneRoof, or another similarly qualified service provider, at your expense,perform such repairs,removal and reinstallation,or relocation. (b) Temporary Removal. OneRoof will remove and replace the System from your roof while roof repairs are being made for a payment of$1499. You will need to provide storage space for the System during such time. (c) Return. If at the end of the Term you want to return the System to OneRoof under Section 17 Of the PPA then OneRoof will remove the System at no cost to you. OneRoof will remove the posts,waterproof the post area and return the roof as close as is reasonably possible to its original condition before the System was installed(e.g. ordinary wear and tear and color variances due to placement of equipment or manufacturing changes are excepted). OneRoof will warrant the waterproofing for one(1)year after it removes the System.You agree to reasonably cooperate with OneRoof in removing the System including providing necessary space,access and storage, and we will reasonably cooperate with you to schedule removal in a time and manner that minimizes inconvenience to you. 5. Force Majeure If OneRoof is unable to perform all or some of its obligations under this Limited Warranty because of a Force Majeure Event, OneRoof will be excused from whatever performance is affected by the Force Majeure Event,provided that: (a) OneROof, as soon as is reasonably practical, gives you notice describing the Force Majeure Event; (b) OneRoofs suspension of its obligations is of no greater scope and of no longer duration than is required by the Force Majeure Event(i.e.,when a Force Majeure Event is over,we will make repairs); and (c) No OneRoof obligation that arose before the Force Majeure Event that could and should have been fully performed before such Force Majeure Event is excused as a result of such Force Majeure Event. "Force Majeure Event"means any event,condition or circumstance beyond the control of and not caused by OneRoofs fault or negligence. It shall include,without limitation,failure or interruption of the production,delivery or acceptance of power due to: an act of god;war(declared or undeclared); sabotage; riot;insurrection; civil unrest or disturbance; military or guerilla action;terrorism; economic sanction or embargo; civil strike,work stoppage,slow-down, or lock-out; explosion;fire; earthquake; abnormal weather condition or actions of the elements; hurricane;flood;lightning;wind; drought;the binding order of any governmental authority(provided that such order has been resisted in good faith by all reasonable legal means); the failure to act on the part of any governmental authority(provided that such action has been timely requested and diligently pursued); unavailability of power from the utility grid,equipment,supplies or products (but not to the extent that any such availability of any of the foregoing results from OneRoofs failure to have exercised reasonable diligence);power or voltage surge caused by someone other than OneRoof including a grid supply voltage outside of the standard range specified by your utility; and failure of equipment not utilized by OneRoof or under its control. 6. Limitations on Liability (a) No Consequential Damages YOU MAY ONLY RECOVER DIRECT DAMAGES INCLUDING THOSE AMOUNTS DUE PURSUANT TO SECTIONS 2 (c)AND 6(C) UNDER THIS LIMITED WARRANTY,AND IN NO EVENT SHALL OneRoof OR ITS AGENTS OR SUBCONTRACTORS BE LIABLE TO YOU OR YOUR ASSIGNS FOR SPECIAL, INDIRECT,PUNITIVE,EXEMPLARY, OneRoof Energy Residential Power Purchase Agreement-14 2014102103 DOCUMENT SERIAL NUMBER 184413 uocuaigu cnveiope w:or rw coo-4 tHo iaoyj INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. (b) Limitation of Duration of Implied Warranties A/NY IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARISING UNDER STATE LAW, SHALL IN NO EVENT EXTEND PAST THE EXPIRATION OF ANY WARRANTY PERIOD IN THIS LIMITED WARRANTY. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. (c) Limit of Liability Notwithstanding any other provision of this Limited Warranty to the contrary, One Roofs total liability arising out of relating to this Limited Warranty shall in no event: (i) For System Replacement: exceed the greater of(a)the sum of the Monthly Payments over the Term of the Power Purchase Agreement and (b)the original cost of the System; and (ii) For damages to your Home,Belongings and Property: exceed two million dollars ($2,000,000). 7. Notices All notices under this Limited Warranty shall be made in the same manner as set forth in the Power Purchase Agreement to the addresses listed below: To ONEROOF: OneRoof Energy 4445 Eastgate Mall San Diego,CA 92121 Attention: Warranty Claims Telephone: 855-785-9554 Email: customercare@ oneroofenergy.com To You: At the billing address in the Power Purchase Agreement or any subsequent billing address you give us. 8. Assignment and Transfer of this Limited Warranty OneRoof may assign its rights or obligations under this Limited Warranty to a third party without your consent,provided that any assignment of OneRoofs obligations under this Limited Warranty shall be to a party professionally and financially qualified to perform such obligation. This Limited Warranty protects only the person who hosts the System. Your rights and obligations under this Limited Warranty will be automatically transferred to any person who purchases the System from you or to whom you properly transfer the Power Purchase Agreement.This Limited Warranty contains the parties'entire agreement regarding the limited warranty of the System. OneRoof Energy Residential Power Purchase Agreement- 15 2014102103 DOCUMENT SERIAL NUMBER 184413 uocuaign cnveiope w:o rrurcoe-v iorwrot.-onoa-oror into Iaayo EXHIBIT 3: BILLING INFORMATION Terms and Conditions for Recurring Payments THIS .AUTHORIZES LESSOR TO AUTOMATIC-ILLY DEDUCT YOLK NIONTIILY PAYMENT FROM YOUR BANK ACCOUNT. 1. OneRoof will provide you with a monthly electronic statement of your account. You agree to review each invoice you receive for any errors.Under federal law,you have the right to hold up or stop an electronic funds transfer provided you give your financial institution not of at least three business days before the scheduled payment date. If you inform OneRoof that an error exists on your statement,we will attempt to correct that envr before the payment date and prior to your next statement. We shall bear no liability or responsibiliy tor any losses of any kind that you may incur as a result of an erroneous statement wherein you failed to give timely notice or due to any delay in the actual date on which your account is debited. 2. If any changes occur in the bank account or email address information on your application,you must immediately notify OncRoof of such changes in writing at the following address: c/o Lease Dimensions,P.O.Box 43,87,Portland,OR 97208. IfOneRoof incurs charge-back fees as a result of inaccurate information you provide,then OneRoof will bill you for those fees. 3. If you either do not notify OncRoof in writing of such changes or do so in an untimely fashion,OneRoof shall bear no liability or responsibility for any losses incurred to the extent permitted by law. OneRoofs sole liability to you shall be OrwRoofs obligation to make any appropriate changes once in receipt of your written notification. The actual settlement date((it date the ACH transaction occurs against your checking or savings account)will be no earlier than the invoice due date. 4. OneRoof reserves the right to change these conditions at any time. Notice may be given on or with your bill or by other methods. Either party may terminate this arrangement at any time by giving the other party written notice reasonably in advance of the date of termination or any scheduled settlement date. If you terminate this arrangement,you agree to send payments directly to OncRoof as set forth in this agreement.Termination shall not prevent a debit transaction authorized before any notice of termination. 5. You agree to be bound by any rules your financial institution requires for pre-authorized electronic funds transfer. 6. Check with your financial institution to see if there are arty fees associated with the pre-authorized payment option. You will be responsible for all such fees. 7. You authorize regularly scheduled charges to your checking or savings account. You will be charged for the amount you owe per your invoice each billing period which will fluctuate consistent with your power usage. os Accepted by(Initials) Please provide Lessor with the following information: Please provide Lessor with the following information: Valid personal email address Checking account and bank routing number A voided copy of a check for the account that shall be deducted OneRoof Energy Residential Power Purchase Agreement-16 2014102103 DOCUMENT SERIAL NUMBER 184413 uocaoign orveiope lu: Nut 0a6 Consent to Disclose or Share Non-Public Information with Affiliates and Non-Affiliates By signing this form,you consent to the disclosure or sharing of your nonpublic personal information('including but not limited to your Social Security Number)to affiliates and to non-affiliated lenders and other financing parties who provide consumer credit or financing in connection with solar lease agreements or solar power purchase agreements(each a"Financing Party-)and each Financing Parry's creditors,lenders and financing parties. You acknowledge that this authorization and consent extends to information contained in your cmTent credit report.as well as any future credit report if a greement with you. This consent shall remain in effect until revoked of modified by Financing Part}enters into a lease agreement or power purchase a you,which may be done at any time. To revoke your consent,contact OneRoof Energy,Inc,at(855)697-2 348. You understand that OaeRoof Energy, Inc,will niainuai❑the true and correct copy of this consent. You are entitled to a copy of the document upon request. To request a copy,call(355)697-2348. You may want to make a copy of this document for your records. Property Owner's Nam7tCAM03117049F e Susan w $Signet by: Signature: �-.at rrr Date: 3/19/2016 Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: Not applicable. Do not sign here. Signature: Date: OneRoof Energy Residential Power purchase r�greetnent-1'7 2014102103 DOCUMENT SERIAL NUMBER 184413 uocuaign cnvoupe iu: or ri,r�co®a-w or-w(ro�].-onao-arar ra a0a0 OUR V FF� Project ID: 85718 lk BY 0,4ER40F ENERGY Serial Number: 184413 Homeowner Design Approval Susan W Engelke 13 PLEASANT ST APT S1 SALEM, MA 01970 Plane 1 r1 682 sgfeet 350 pitch 81% sun rF 2460 azimuth Initial I, Susan W Engelke hereby accept and confirm that I have reviewed the roof design layout. I am also aware that the installation team, based on may do minor corrections. Susan W Engelke £ 3/19/2016 Homeowner name F.- Date uocuaign cnveiope lu:or coo-v orwrou-cons-orar vo iaoao �., [IN`rrrr EICIFs E N E R 0 Y DEA. DN:E SCIL4A PROPERTY OWNER CONSENT Property Owner: Susan Engelke Property Address: 13 PLEASANT ST APT S1 City: SALEM State: MA Zip: 01970 Phone: (781) 535-1422 1 hereby give permission to One Roof Energy, Inc. DBA ORE Solar and its contractors to pull the required permits for a photovoltaic solar installation on my property. �OocuSigned by: ' Signature: Date: 3/19/2016 uocuaign envelope iu:otri,r000� fAO iaaao Page 2 Who is providing this notice' OncRoof Energy. Inc.(OneRoot) is providing rhis privacy notice. How does OncRoca To protect your personal information from unauthorized access- and use,we use security measures that protect my personal comply with federal law-_ These measures include computer safeguards and secured files and buildings. information? How does Oneftoot collect we collect your personal information,for example,when you my personal information? ■ Apply for financing ■ Apply for a lease ■ Provide account information ■ Give us your contact information ■ Give us your wage statements We also collect your personal information lirom others,such as credit bureaus,affiliates or other companies. Whv can't I limit all Federal law gives you the right to limit only sharing? ■ sharing for affi liates'everyday business purposes—information about your creditworthiness ■ affiliates from using your information to market to you ■ sharing for nonaffiliates to market to you State laws and individual companies may give you additional rights to limit sharing. See below for more on your rights under state law. 1 • Affiliates Companies related by common ownership or control.They can be financial and nonfinancial companies. Nonaffiliales Companies not related by common ownership or control. They can be financial and nonfinancial companies. Joint marketing A formal agreement between nonaffiliated financial companies that together market financial products or sen ices to you. ' ■ ■ California Residents: We will not share information we collect about you with nonaffiliated third parties, except as permitted by California law, such as to process your transactions or to maintain your account, or with vour authori=ation. In addition, we will not share infbraration with our affiliates except us permitted by California law or with your-authorization ■ Vermont Residents:We will not share information we collect about you with nonuffiliated third parties, e.rcept as permitted by Vermont law, such as to process your transactions or to maintain your account, or with vour anthori-ation. In addition, we will not share infoivnation with our affiliates except as permitted by Vermont law or with your authorization 2014102103 DOCUMENT SERIAL NUMBER 184413 uucuaiyn cnveope tu:o r ru r coo-w Ior-vroi.-ooao-pror No eoao Page [ Rev, May 2013 wHA'r DOES ONEROOF ENERGY,INC.(^ONEROOF")DO WITH YOUR PERSONAL INF'ORtNATION? Financial companies choose how they share your personal information Federal law gives consumers the right to hour soma but not all sharing. Federal law also requires us m tell you how we collect,share,and pmtrct yom personal information. Please read this nonce carefidbv to understand what we do. w` The types or personal inrunnarion we collect and share depend on the product or service you have with us. This information cart include: ■Social Security number and checking account information ■paynncnr history and income ■credit scares and credit history r �7 All financial companies need to share customers'personal information to run their everyday business. In the section below,we list the reasons financial companies can share their customers'personal information;the reasons OncRoof chooses to share;and whether you can limit this sharing. Nil 1 For our zveryday business purposes—such as to process your transactions,maintain your account(s). Yes No respond to coon orders and legal investigations,of report to credit bureaus For our marketing purposes—to offer our products and services to you Yes No Nor Joint matkcting with other financial companies Yes No For our afti hates'everyday lost ness purposes—information about your transactions and experiences Yes No For our affiliates'everyday business purposes—infonuation about your cteditworthiness No We don't share For our affiliates to market to you No We don't share For nonaffiliates to market to you No We don't share To limit our sharing, Call(855)697-2348-our menu will prompt you through your ehoice(s).Visit us online:www.oneroofenergy.com or mail the form below.Please note: If you are a them-customer,we can begin sharing your information[301 days from the date we sent this notice. When you are no longer our customer,we continue to share your information as described in this notice.However,you can contact us at any time to Timm our sharing. r Call(855)697 2348 or go to www.oneroofe-nergy.eom r Leave Blank Mark any/alt you want to limit. OR ❑ Do not share intbrnration about my creditworthiness with your affiliates for their everyday business purposes. [If you have a joint account, ❑ Do not allow your affiliates to use my personal information to market to me. your choice(s) will apply to o Do not share my personal information with nonaftiliates to market their products and services to me. everyone on your account unless you mark below, Mail to: ❑Apply my choices only to 4445 Eastgate Mall Rd, OncRoof II me] .:; _ Suite240 San Diego,CA 92121 Ys:a 2014102103 DOCUMENT SERIAL NUMBER 184413 uocuzngn envelope iu:or rut 000-v ior- ,rDu-ooao-orot iro iaaaa y� E N E 6i 6 Y DBA DP5 .D Lag Y Power Purchase Agreement Production Estimate Addendum Schedule of Termination Amounts - M 5 $7,133 6 $5,980 7 $5,925 8 $5,859 9 $5,778 10 $5,681 11 $5,567 12 $5,435 13 $5,286 14 $5,117 15 $4,928 16 $4,717 17 $4,484 18 $4,225 19 $3,938 20 $3,622 As soon as you acknowledge the above design and production details by signing below, we will schedule your installation. If you have any questions or concerns please contact your Sales Representative. Susan W Engelke D000slyoed by-. Not applicable. Do not sign here. Signature: S—, E`-},.,t Signature: Date: 3/19/2016 Date: Not applicable. Do not sign here. Not applicable. Do not sign here. Signature: Signature: Date: Date: Not applicable. Do not sign here. Not applicable. Do not sign here. Signature: Signature: Date: Date: Not applicable. Do not sign here. Not applicable. Do not sign here. Signature: Signature: Date: Date: PPA Amendment Dated 3/17/2016 Page 2 of 2 2014102103 DOCUMENT SERIAL NUMBER 194413 uocuaign=nve,ope iu.or ru r 000w ar-vroL.-n0000ro i I r o I y"j ONEROOF' E N E R 0 Y aex ORE WLPR Power Purchase Agreement Production Estimate Addendum Congratulations ! Homeowner Name and Address Co-Owner Name(If Any) Susan W Engelke 13 PLEASANT ST APT S1 SALEM, MA 01970 You are on your way to clean, more affordable energy. We estimate that your System's first year annual production will be 2,807 kWh. Over the next 20 years we estimate that your System will produce 52,445 kWh. We also confirm that your energy rate will be $0.105 per kWh, (i.e. electricity rate $0.105 and tax rate $0.00). Your energy rate, exclusive of taxes, will never increase more than 2.9%per year. We estimate that your average first year monthly payments will be$24.56, however actual monthly payments may fluctuate throughout the year based on natural changes in sun exposure. The following is an example of how power production and monthly payments may vary through the year based for your region. 1 183.40 $19.26 2 184.33 $19.35 3 264.46 $27.77 4 254.96 $26.77 5 288.78 $30.32 6 292.64 $30.73 7 304.42 $31.96 8 355.34 $37.31 9 267.00 $28.04 10 179.66 $18.86 11 123.46 $12.96 12 108.53 $11.40 PPA Amendment Dated 3/17/2016 Page 1 of 2 2014102103 DOCUMENT SERIAL NUMBER 184413 uocuaign cnverope w:or rut coow i Ho i aoa3 EXHIBIT 5 HOME IMPROVEMENT CONTRACT DISCLOSURES 1. Registered Contractor.Each contractor and subcontractor performing home improvements in the Commonwealth of Massachusetts must be registered with the Office of Consumer Affairs and Business Regulation ("Office"). OneRoof s home improvement contractor registration number with the Office is 172197. 2. Subcontractor. The name, business address and home improvement contractor registration number of any subcontractor that OneRoof intends to engage in connection with the mounting of the System at the Property is set forth below: Name: Address: Registration Number: Taxpayer Identification Number: 3. Inquiries. Any inquiry about OneRoof or the subcontractor(if any) should be directed to: Office of Consumer Affairs and Business Regulation Home Improvement Contractor.Registration 10 Park Plaza, Room 5170 Boston, MA 02116 (617) 973-8700 4. Start and Completion Dates. The approximate start date for mounting the System and the approximate completion date for mounting the System are as follows: Start Date: Completion Date: 5. Copy of Signed Agreement. OneRoof will provide you with a copy of the Agreement after it is signed by you and by OneRoof, prior to commencement of the mounting of the System on the Property. 6. Permits. It shall be the obligation of OneRoof to obtain any permits necessary for the mounting of the System on the Property. If you secure your own permits, you will be excluded from the Guaranty Fund provisions of Chapter 142A of the Massachusetts General Laws. The following permits are required and will be secured by OneRoof as your agent: OneRoof L"nergy Residential Power Purchase Agreement- is 2014102103 DOCUMENTSERIAi_NUMBER 184413 SOLAR HOMEOWNERS AUTHORIZATION FORM Engelke, Susan (print name) am the owner of the property located at address: 13 Pleasant St. Apt S1 (print address) I hereby authorize Trinity Solar, and their subcontracting company , to act as my Agent for the limited purpose of applying for and obtaining local building and other permits from the Authority Having Jurisdiction as required for the installation of a Photovoltaic System located on my Property. This authorization includes the transfer/re-administering, and/or cancellation oj any existing permits on file for the purpose of updating/app ing with an alternate subcontractor. Customer Signature: Date: 3/19/16 Print Name: Engelke, Susan Optimize Engineering Co., LLC P.O. Box 264.Farmville•VA 23901 Ph: 434.574.6138.E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President April 1,2016 Salem Building Dept. Salem, MA Re: Solar Electric Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure, roof loading, and proposed site location of installation: 1. Existing roof framing: Conventional framing true 2x7 at 24" o.c.with 6'span(horizontal rafter projection). This existing structure is definitely capable to support all of the loads that are indicated below for this photovoltaic project. 2. Roof Loading 4.33 psf dead load(modules plus all mounting hardware) • 30 psf snow live load (50 psf ground snow live load reference) 4.5 psf dead load roof materials Exposure Category B, 105 mph wind uplift live load of 16.29 psf(wind resistance) 3. Address of proposed installation: Residence of Susan Engelke, 13 Pleasant St.Apt St. Salem,MA 01970 This installation design is in general conformance to the manufacturer's specifications,and is in compliance with all applicable laws, codes, and ordinances,and specifically, International Residential Code/IRC 2009. The spacing and fastening of the mounting brackets is to have a maximum of 64" o.c.span between mounting brackets and secured using 5/16"x 3 Ys' length corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter &min. 2" penetration of lag bolt per bracket,which is adequate to resist all 105 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters for better distribution of roof load. Penetration of anchors for modules mounted within 18" of ridge and edges of roof is to be a minimum of 3". Very truly yours, Optimize Engineering Co.,kLC ��F MASS', 9 Richard B.,'Gordon, P.E. ° o m Massachusetts P.E. License No.49993 aicORDON GOftDO �. ` G I,AECHPNICAL �, t U NO 49993 CIVIL, MECHANICAL, &ELECTRICAL ENGINEERING ,_l� '''-c sTE�`�o� '! G �j SSOW- INSTALLATION OF NEW ROOF MOUNTED PLEASANT ST.APT S1:o 3. 12kW PV SYSTEM � F 13 PLEASANT ST. APT S1, _ , SALEM, MA 01970 IS.�;.a r wl.isoae VICINITY MAP SUSAN . SITE a. SCALE NTS Proleal Tue: ENG ELKn.xnnrrnem E, lEMrtuccT IEDF 1 PrecO.AtlamSs ES PLEASANT ST.APT SI, SALEM,MA I)19J0 a D SHEET INDEX PV-1 COVER SHEET W/SITE INFO&NOTES DITR nn.. s o' -a RI O e ` `r�""""L5 PV-2 ROOF PLAN W/MODULE LOCATIONS PPovoseo a.5zkw DIRE TO4SAPOINSTRUILIOUT "PRIORo u 0..t. SOIAP SYSTEM a or O O d' u o PV-3 ELECTRICAL 3 LINE DIAGRAM .o0o was eP 0 r rum FIFNIUTUUTK E S 00 e a. TP�-1 .AA A ox�:Kn: rtl.vzn. O O 0 0 OSOT.P.60 B E RK, q00 w5 E B C O k5 FEAprx." EU D'F..nr:FU 1T Oli s u.,0.; -1nP.ALLlr`.rllrllN6:k:, w.a"aim SEEP.A"a� 'ei1 IIEsw.r Ssre�n o-rormanom I. ALE r.: .1 DO.T.E ssL nsrior.rs a J ruTEc O" TOOTALL D5TNM SEE s-¢Ew 6 w.M L 0 E IMF.FI+; a D O 1. r.E .ururv. Thl - HTrEuuTs °n a oD a0 oS FAR ITO-1 q 55 S AIDE I' 111.DJ E CF .�[[I. vE[ F EF iYrE ASD"� _ 6 1.E x I�A PER 11 iPOVEN"u rrtarin.i,[SR. URAIFN rrh � EILE1 11 111111INDEATE1 NA sc w O w NOT ll.�NDIIIER o a- rI.NERPERROF.Nn. Shxl q e Onau w ,,, v . �.': Aeo EFI Su-D F.00?O". . A a P1 PV - 1 TEu 11 1. 01h p5 MT ��F TROAL SYSTEM �` . TE VT_ COuiau�5-1 FE Tw TV[n0 O FIFIIEE"I 5 CO F0 5 O NFUUL Il S[Ex i IEN h q E T 'nr �® 0 A111 SP 0 CA OTS fi` .ESA a, RU wTr,. 5 .x'OTE., I.E. REFU ATn.nE..um..xu AETEI Or1E.T FRO r, PLEASE eEAmIS PDear I I RAL maFUEnr ANUu Ill E,wwnT TI AT I.I O.e.TT ww,:r Ill O_;ALk 11Or IOU w.E1T. nn ram.roe Pom en-m-lsn vnIEIFL FLAN. T Ei6 �, MP .x cPlC9 FIIDOWNTTEfl N Wi111UT96N4H11 1 myl.LT TIP0.1 TO.FCING :4Lu4 LlnouLE SnnN fcoul,e E `3 5' FI.K'[LF xT NW NFACN AII' N ui. e , \ Iv. 1 " - IX HT ( AFN AC U6 WO G 0 EI.'T uy , ' [EI 5 IN* RF H[SEA ,,�J ELAYER ASFHFLT SHINO.�$ E ////// W XECTI9 a. I.Wi POIi AP{h;SEFUNIeam rcrrc V . /\ SG tlo LFR MUCULE381NLLNOT '/I,NvTOL U iT TASAEETFTl ='tlsTIrvN RA6TER ExGEEo i'IF ll.0 l ♦1 1 1\=\ }TATTAG LM RCLIP DETAIL N ACTLAL PU[aawPxduls^ TPV MOOULEATTACHMENi ON ASPHALT SHINGLE ROUF T:'EIGHTFLOTRGM GRGIINULEVEL TOPEAK OF ROOF NO7 IseuOtl/Rw,,,IrP oc M No P c 1—'ll D 111 11t HhcN TxIxERNOEIXE Ne e1a1 Proca ANtlTss ' 13 PLEASANT ST.APT S1, C$= _ SAIfM,MA019)0 rri Orav/In Ttlle'. FRONT' -� BACK PRUPOSE03.l2kVJ SOLAR SVAEM zm ITT; OL .e . smlT ITITTme.P. I ITAII.T�E, R1 n a R7NO ShLUI 4) ROOFTOP SOLAR INSTALLATION ONLY PV ARRAY WILL NOT EMEND BEYOND THE EXISTING BUILDING ENVELOPE ARRAY SCHEDULE SYMBOL LEGEND PLUMBING SCHEDULE- EQUIPMENT SCHEUULE P1 PV - 2 ® EFa LUN V Ecpa.MI1E1FORA41ipN VD T. O iN Ei Ru.ccxlECT TORE NA + (FM360?005Od1 aF EF IN I'L O E '.L p OTHER OBSTRUCTIONS G. ro I e0 +L16R TO L ix6If q�'�OTE. q .1103E 0 =1.NnyOi RMOT)-M7-DTO © .ul YS C u sCNIOIT I'll S111 I MY4 Nn MYy O)R9TrINt Eng:rcor/Gccnsc HOlticr'. 10 1- "N.NDILIt E3'At/t ITI EDGE PILSN Nu t'IUEE IEJSPGC MxI PEP SraWG � I SSwW YP t]uOXUIP.S MSExNz.3f0Vma ______ B'P8" ____________________________________________________________ _ ______________________ \ JYNCIICN , P F eox I i I 1 I I ISEYee/RxmsrOns I I I I I II PnDN EOEDEIL RmlecliTle r:Pccr n: MEN.LNlo N[sunlP mnPNPnoNix PttOEam¢wrtx x[Uov< Nc ENGElkE,505AN E.IL,"SETENJERiu AMP1EKTTEMPgPN.hP EASEEOX ]Ix 41u4141 11 INS El MEALTEL Y NIO E 6a ME—TARE PIa oG NemoSS Ewsnuc 'o sA eREMER 'P 13O/]WV 2,oV Iq 1n IN E. I ^ A I e s E M IDOA MNNOUee NR6A 13 PLGSNrvr sr.APi si. cPE l N-111 xt;tEi IIIXOO<nEn A SSLeM,Mnolv]o 1 LoolAele ew ul� - P O E 1 olsrANxEEI Nsm w/ 1 1 - J 20A NSE5 PROPOSEC 3.11kW (ApIPW w/MAIN JDA UNNYO pEWVLnOx SOLhR 5Y4[Id Ul ONS G 8REM2R LOAD ENTER OSSO I NCRR 0 IX0 G 0 E L of xrt s ai 2wv tw z,av t _ o t -W OIL �� ]PL iD s. DarD tO. vLx1 L 1 ¢ t��� wE II r•'-- s 1 r 6 ZI lE uis-aSDxD EOeYs POsi OXZOP `( E 5TRIO NNN DREAHER LOAD sOUARE D sWARE O �� ______J -Lt CT— IS y CE34MR INSILAIED LINE TAPS PN. D222N _------- V LI11z4m rx1111E4 U FD On OF In 6UIILxIGE IxSTANF➢ON NAN FFIDWS 9 TALIN� CxPp USh�UIM WlI PIXCII ONINAI K 690.W I.I.W O 1LNNL WNiOt6lfl AESONOPx@ WiM LETEs¢IIinIPDusI�Rl CAIEUUIIONE.EUPREMI IAANEING LIA.T.S. 0 IS INEccm ILL IE,aJ¢iSAll tatia.I All, rt 9t2o Pccswl ,ATE _1 Rev.ND Slt<rl )I IJ t EN:RGIN IREE IE , , P1 PV - 3 W[.ENtE11lr. CLTI nM PP<I, S 1L11�.SLl1lHA11,11Ll I'll - ® A tut FE N[ MEEIS ALD,DA� .1 EA .„FDA nn A9Nt.om Revean-99)-29n -,E.^A ovss-vRR1Nr PFDi_almN Isv.YD wVl x.w J�Nn Dma Optimize Engineering Co., LLC P.O. Box 264.Farmville•VA 23901 Ph: 434.574.6138.E-mail: grichardpe@aol.com Richard B. Gordon, P.E. President April 1, 2016 Salem Building Dept. Salem, MA Re: Solar Electric Panels Roof Structural Framing Support To Whom It May Concern: I hereby certify that I am a Licensed Professional Engineer in the State of Massachusetts. Please note the following conclusions regarding framing structure, roof loading,and proposed site location of installation: 1. Existing roof framing: Conventional framing true 2x7 at 24" o.c.with 6' span (horizontal rafter projection). This existing structure is definitely capable to support all of the loads that are indicated below for this photovoltaic project. 2. Roof Loading 4.33 psf dead load (modules plus all mounting hardware) • 30 psf snow live load (50 psf ground snow live load reference) 4.5 psf dead load roof materials • Exposure Category B, 105 mph wind uplift live load of 16.29 psf(wind resistance) 3. Address of proposed installation: Residence of Susan Engelke, 13 Pleasant St.Apt S1, Salem,MA 01970 This installation design is in general conformance to the manufacturer's specifications,and is in compliance with all applicable laws,codes,and ordinances, and specifically, International Residential Code/IRC 2009. The spacing and fastening of the mounting brackets is to have a maximum of 64"o.c.span between mounting brackets and secured using 5/16" x 3%" length corrosive resistant steel lag bolts. In order to evenly distribute the load across the roof rafters,there shall be a minimum of 2 mounting brackets per rafter &min.2" penetration of lag bolt per bracket,which is adequate to resist all 105 mph wind live loads including wind shear. The mounting brackets shall alternate between adjacent rafters for better distribution of roof load. Penetration of anchors for modules mounted within 18"of ridge and edges of roof is to be a minimum of 3". Very truly yours, Optimize Engineering Co., LLC Richa� d B,,Gordon,Rtl. OF MAS c e Massachusetts P.E. License No.49993 �2�aPH sq yGN O RICHARD B. a ' CIVIL, MECHANICAL, &ELECTRICAL ENGINEERING o DORDON v U MECHANICAL NO.49993 Pg.•-.P INSTALLATION OF NEW ROOF MOUNTED PLEASANT ST.APT S3.• 3. 12kW PV SYSTEM � `�''�= 13 PLEASANT ST. APT S1, SALEM, MA 01970 IssuRtl,RovlslOfts VICINITY MAP FO. w - I,�!fiox scale nlrs SITE N" Pmle.t TlU, EN6FLttE,SUSAN TwuuRvnccf.11IF-PRAT Prol<Gt All 13 PLEASANT ST.APT 51. SALEM,MA 01170 SHEETINDEX m m f O :m rme: G RLTEE FFCR ALE PANELS IS Ill LE TIFFIN T % PV-1 COVER SHEET W/SITE INFO&NOTES ofa. EPTIFOINT ARE - AF<. o Ts F,T!ns PV-2 ROOF PLAN W/MODULE LOCATIONS Paovoseo 3lzkw b _ EI yISAF-RFALI RESSFISw' a°^TTF"J^ PV-3 ELECTRICAL 3 LINE DIAGRAM somasysrEM APEONALL ¢ u JLNE R . Ges EO -u 0 pO Oku s E - - FINATTLEENSAND E O 060 SHF B E 5Fo 5! ARE FILE I HARTAT T9N J<NE[P.Y 1111ORJCf�E Nmf GOxSTRUC Nlx lCOiM1 IEY. R kG+O- HE aau RRGwIJE+Rnu- 'A SlImc,mrofinenonEFIFIFFNIFTEINI : 69a'RTO TFE NSHTALLATEFI OF TRs ^: L MVO 6 s IFTI_T On O C O. OAS IT. clPAR,f P ITS.FUNIONITAT I11 A.TENIN ALI I, -.uF<oxruT y a o w,Reuu s s. . oATHRE OFm-R "E ES c s s s ul°Fv,;:fs Re w°_ .1 ISm- _. .SEE. on.f: C 0 I. El �FMPn OF E vVC 11 V ,FRO A. RIIEIIIAFR E E CO CJCfM1' C C 6 O" AA�jo Oe u T. O O O O .O a Rn.NO. Stn:<t w E11L.AFFEASSFER..AIR O OAT pVy M R80.cN "_o'!.A E-. eEA, AFF, LPAP R ' P1 PV — 1 91(K, O 5 O XrtGnufKT6 nuISTIEf REFRIE ALL 5. O.. F:R AT C L tP,I O >Ei IS NOTER '3 hC GLC A I,LISTED PI F(OLPHENTE�ILL NE ArIAP PGEEI aurtui 'Al, 0. !x 5 ,-sot" iTh i..dAASEE Eunt. RE Om IR RAE.TT ::EJUE O-\AfA. T.or SHILIVE"T. vtt w.f.00a xom an-M-leTe omn UpJ. F E .VIE NN r. 'RCKL A•AP�Mb Y � nnGEW IMn'rtv pOnErII - I 5 i F�Op P/,CINO SOLAR LIOpVLE !ILIA MO0VLE FT IF'OP _ XV NPACRrvI_FOuF NA NFAC:PAIL r REENR 6. Ex FLA L ;1 C:F 5 1 G •y ERFOF 1 $N' PA KEA'E �JNE OVEP ASPINLT$UNCLE$ { 5 0 G RFOn -urlA 60LT E.yTh+AFlaim •—� ur N.45 cRFOv SOLAR MOD VEES SFIEFT,f E lSilr PP}[. EYLEO PEAK HEIGHT. A� 1 N L EN IOMOII6FEESFOP. T�ATTAQIM=NT&CLIP DETAIL AML -[DOGULE OlDcN1W5 Er MC DULEATTACHMENTQY ASPHALT FHINGLE ROOF pHEISHT FROM GRCUND LE'✓EL TO PEAK OF ROOF .aE.ROD�c SCN� ♦/;wFrcT*oscuF- IssueO/Revlcions M uD P a< D PrILN�� 3 ENGELKE.SUSFN . T61NR A cT 1C11116,DI T Pry O^,Atltl ns' 1't�tL� SHLEN,MA Ol!l)0 FRONT SACK PROPOSED 31)kVV 50 AR SYSTEM `1+ L O ZF ln formation /6 + I a,zcr. . SICIi1 FIIII IRi8+I0i V Ifi+IN11'r'M1ryaIW+1 R9 'Ia s s a O Roc No. ShO01 a)'ROOFTOP SOLAR INSTALLATION ONLY PV ARMY WILL NOT EXTEND BEYOND THE EXISTING BUILDING ENVELOPE ARRAY SCHEDULE SYI.eOL LEGEND PLUMBING SCHEDULE EQUIPMENT SCHEDULE r V L 5 ® . F.r.[,Ir E-11 LI0,F OPUITtla UD T I vl rY PLFQMIECI 106E 0 SpECY L I� 5 lE !'IN4'FJIISM660PWEW 1� Iry11 E C .US f J 5. z�I O I HEH 09GI HUC PIONS en .rE C u sE a >nL. e-,Ea rr sE L I n FIv r a , L O [„TE Y6EONNEGI OSE ® 'IF- 6 S11I All";RRI all-M-RIVI I+tF FTo OT1Y E.RF IEF.D),E a wL rM J•Ml TM Eng.NcorI Liernsn Holder. x M09ULEsMWrvr.....Cr"e tI I I rsx% [951NGC.-v[A M9FNtF — :e]SA9CN .0.a J r PxIn40E rl rnOrY!IES IN SExX531n'✓me< JYNCLAION -r �I \ jIII Revisions I I I I I won nsalou cNwxo °uleclralxe I nuAnilox iry PccaaoucrwrzN x2]ou ENGELKE,SUSFN I ry I nvnLcx soEsmmm ]'Sr�E��u iLe F61BIENrreuPEAPruxe LPifL ory I F 6cl BREMf1£ Pra a:E Aeernis E,/,AL LOU NRf/MER I'll !z9/zwv s+av io +�'N.cJee 5.- i e M uaC eASEo ETR M IO]AUAIN RREIJffR 13 rLEasANr sr.APrs1. 'GALIPOIA. "y MERR tWn BUSBM rr- 1-1 SALEM,MA 01970 siuPraxEmLOONO ElxfriINIXLam wp- 1 0 Es ks LwuRE£6YA f XA '1 pgrpm /Nix WA UNNSE MRIERH 0 0 f ISCMNELi R OULT ION L M BPEMSR OAd Cf NIEP 0 11 o m.o .1. xw i l , ItlYF86B.J1 D p BW I.to 1 n IG I J N L- — `I � x .� � AL AIINI OIL." 1�1IALNA1NN1.1I.1NHd1.1 P eI A. TO fiPLf U LLI L _7NIA r--- ) IL -M----r. � B B _ - E :+U $ l I Io aRe EMISTNG NNN BREN(ER LOA➢ I 1<)5 ry L nlw x11OE. .AAAA..l cf N< ♦1p rv( s.n a mP ra soi 90UARED SWAREO :_J LD'O"YEcnu!. J y C£N1fR IN$ON MA I1NE rM$ PN: p�32N URRIRB J MOu!LFiusFo. 9Jv11SI,c£N1AAAI151NS.ro,.Orr Oalry euu9Nr65 IXSrpLIID ON MAIN fFmFRS 90,WUIAII EttrrlrErNaollli lCY lro�.Slirn(EOp9PNrtWIiX LALNLAIII 1.ILARINT dANNI AAANNJCF.. Loci. E "'Ho.N YI?DC:! do IxEcem.Ele101L Ns mvSM•re'sA J ,Nv o .yAPre 1. -IN o.111 Roc No. 9M1imr M[1AI OIIAII� .Wl _ I E SYA119 3L2 A I., -111.111.1;4dLIA1 NO, ,Py °new 'v Pmrx ry y..pcxliror we a adEOA11S'I'll "A r w• u w a 20 I'll"INIVNI �S{?LAR e>iW w5E¢cuaFEf➢FxmECTaNIS VPUU v11.10mvM RM1err-rp)-981e rul.NNN J.«E omE Snap rack- Solar Mounting Solutions Series 100 Residential Roof Mount System The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic (PV) module installation system. Series 100 UL is listed to the UL 2703 for grounding/bonding and fire Classification. The System's components provide an adequate bonding path which has eliminated the need for grounding lugs and wash- ers at each module, and bonding jumpers between splices. In addition to grounding and bonding, the roof mount system, Series 100 UL, is Class A Fire Rated when in- stalled with Type I and Type II Modules. SnapNrack's UL 2703 Certification and Com- pliance ensures that SnapNrack installers can continue to provide the best in class installations in quality, safety and efficiency. • Appealing design with built-in aesthetics • No grounding lugs required for modules • All bonding hardware is fully integrated into J i the components • Rail splices bond rails together, no rail jump ers required • Proprietary SnapNrack grounding lug snaps t KT in the rail channel n- • No drilling of rail or reaching for other toolsf required a " • Class A Fire Rating for Type 1 and 2 modules System Features Include Or Snap in Single Tool Easy No Cutting Hardware Installation Leveling or Drilling Integrated Wire Preassembled Integrated bonding UL 2703 Certified Management hardware Resources snapnrack.com/resources Design configure.snapnrack,corn Where to Buy snapnrack.com/buy Snap rack- Solar Mounting Solutions B . Ste s!e 51ae1 soe I.t] dill, — nP 1 ack;I—J id lad t tl -"'fit $pl -nt L F y IYs SIA." e reck o jI 1 @td: htt I p A Nxk i apMe ABG rPr! g9 d J ^'+tll+rWblalea NnNI PLL,t .Ciamp BeltdaIts,lit l—k dome eh, B t L Sn tashnrs P ILC<S r SnapNrack 8an', .al Adiusteba End Clamp SnapNrack Bantling SnapNrack Bonding Mid Clamp St. d d Auul spll a tapu J :upper Wee I SnapNrack Ground Lug Assembly (ONE REQUIRED PER ROW OF MODULES) �" I k Eonciny Unrv=_rzal Entl ClamP!UEC)wa.2 i-VECPUII SGap 41EC W=dge Stamlesa St�J 0M[ .mm Flat mash", SnapNrack Bonding Universal End Clamp sndpNrach Bantling Stando Clamp Assatnbly 7 snapnhapkl� Semate65lmnere J' .-5naprlreeft SnapNrack Bonding Public, Staat Fbva¢Nut Bondupg Cnennel Nut Lt@nn¢r •'roimeza Rags Cdtaf senuted 5tacrte5s Me i Flange wut steel Reege San SnapNrack I Scainles. SnepNrttk-�.. 9_Degra � MITI Flnah Foot Bolt 5landou y -SnapN2ck SnupN a[Y IIO pose MJIFnKh� LF t standdr Bmi(I Nae <�aFNrxF s p 1 -k SaS45hown) Foot MMel9 f MIIIF e �o FLahrn9 B A x'nbl'p L Fcic. B SnapNrack Bonding SnapNrack Bonding SnapNrack Metal Standoff Assembly L Foot Base with Flashing Boor Base with Bonding L Foot SERIES 100 TECHNICAL DATA 6.u. -° - • 6000 Series aluminum `• ,. .I. ` '" r ' Materials • Stainless steel • Galvanized steel and aluminum flashing • Clear and black anodized aluminum Material Finish • Mill finish on select components • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification Calcs.&Certifications • Class A Fire Rating Type 1 and Type 2 modules • Stamped Structural Engineering Reports for all 50 States • SnapNrack Grounding Lug (One lug per individual row of modules) Grounding • Integrated bonding components Warranty - 10 year limited product warranty; 5 year limited finish warranty 877-732-2860 www.snapnrack.com contactta_,snapnrack.com . ',u.. --, w"cn - In Iny _;I„ i i , All t ,h c It'Ot 't . SNAPNRACK SERIES 100 ON FLASHED L-FEET RevlsiGN• FLASHED L-FEET ARE OPTIMIZED FOR QUICK AND ROBUST INSTALLATION ON STANDARD COMPOSTIION SHINGLE ROOF SURFACES FOR OTHER ROOF TYPES STANDOFFS ARE RECOMMENDED 0031cinm�! C=..HLrrinrrrrnCrC e SNAPNRACK STANDARD RAIL .. 1 5` ROOF RAFTER TYP(ROOF ATTACHMENTS SHOULD ALWAYS BE EMBEDDED INTO ROOF RAFTERS OR STRUCTURAL MEMBERS SUCH AS STEEL PURLINSO ROOF SHEATHING,UNDERLAYMENT, I AND ROOFING MATERIAL® i ITTfI IIEDED ULLI ILBif i I sM j�(j,\'J P� r MAINSTREAM ENERGY CORP DESIGNER: G McPheelers SCALE. ® PARTNUMBER: DESCRIPTICN REV U�yillGiN T`a'V`Ll�. rtp�'""�" a""���'° "�" � DRAFTER' oR>'d" 8100 DOI SERIES 1000VERVI E4V. ON FLASHED NNJ P9k+seFaEFR $jr1'1$e"06� .-'.,.,.... ••r„ APPROVED BY: DATE'. ® L-FEET F REJISION. SNAPNRACK MODULE ` ATTACHMENT HARDWARE SNAPNRACK STANDARD RAIL L I R AND ROOFING MATERIALIAL OOF SHEATHING,UNDERI NT, �•_` r ® I ROOF RAFTER TYP(ROOF ATTACHMENTS SHOULD ALWAYS BE EMBEDDED INTO ROOF RAFTERS OR STRUCTURAL MEMBERS SUCH AS STEEL PURLINS EElEFl TITK=7iF nrrmrrrT WIGIE•� `O\ MAINSTREAM ENERGY CORP. DESIGNER: GVkRMM.a SCAL MB E: ® PARTIAIIER. DESCRIPTION P-y &VS�%(7 1(a ' oRRETea: DRr. 5700002 SERIES 100 OVERVIEW.ON STANDOFFS l ( @6TT5$Skti �5 .g7Jt'. •^.;:,r:�a; :x�A-•a::.s: APPROVED BY'. DATE: ® F SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT REVISION NOTES: -STANDARD LAG BOLT SPEC ASSUMES 5/16"LAG BOLTS WITH 2.5" EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS -TORQUE ALL, "HARDWARE TO THE FOLLOWING: ROOF RAFTERS OR -SILVER S.S. 10-16 FT-LBS STRUCTURAL MEMBERS -BLACK S.S.7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF POST(UPSLOPE CE DOWNSLOPE) -FOR UNEVEN ROOF SURFACES, USE MID DAPCNRA MODULE MODULE OVERHANG UP TO TWO LEVELING SPACERS PER L FOOT OR STANDOFF.SEE DRAWING (NOT TO EXCEED 300 "STANDARD RAIL LEVELING"FOR \,+ \",. OR MANUFACTURER'S DETAILS AND LIMITATIONS �� RECOMMENDATIONS) r MODULE OVERHANG . STANDOFFS ARE BOLTED INTO ROOF RAFTERS OR STRUCTURAL MEMBER "RAILSPAN" DMANCE BETWEEN ROOF ATTACHMENTS i "RAIL END OVERHANG"(NOT TO EXCEED- 34%OF ACCEPTABLE RAIL SPAN) rrtnlr? hWINSTRERM ENERGY CORP. DESIGNER: GMcPlreaer SCALE DNS PART NUMBER: DESCRIPTION- REV sinxa�'lrrack DRAF ER D Rye" DATE S100 D05 SERIES 100 TYPICAL LAYOUT PyInoa I6j^.0n� APPROVED er 120113 - 1X SNAPNRACK -2X SNAPNRACK LEVELING REVISIo.� USE CARE DURING LEVELING SPACER SPACER - INSTALLATION TO ENSURE THAT THE SET SCREW IS -1X X 1"LONG -2X T'V-18 X 1"LONG ROUGHLY CENTERED BETWEEN g SEI SCREW R SET SCREW THE TWO PIECES BEING[DINED Yl Li n' ,I ANDARD SERIES 100 ATTACHMENTS FEATURE 3"OF ' - l VERTICAL ADI-USTABILTIY ON ALL MOUNTING POINTS WITH I HE USE OF I"LEVELING C® -m SPACERS ® ® THE FIRST INCH OF ADQUSTABILITY IS ACCOMPLISHED WITH SLIDING DETAIL A FEATURES BUILT INTO HOIH L SCALE 5:8 FOOT AND STANDOFF CLAMP COMPONENTS r I I I RAIL HEIGHT 07.5" =RAIL HEIGHT M.5" g RAIL HEIGHT C9.5" RAIL HEIGHT[10.5" FOR AN ADDITIONAL INCH OF i.ABOVE ROOF SURFACE ABOVE ROOF SURFACE ABOVE ROOF SURFACE ,r ABOVE ROOF SURFACE HEIGHT ADF ST MENT,ADD 7"STANDOFF 7"STANDOFF 7"STANDOFF 7"STANDOFF ONE LEVELING SPACER. USE i PLUS ONE SPACER PLUS TWO SPACERS OF SINGLE LEVELING SPACER ON TOP OF STANDOFF ON TOP OF STANDOFF NOT TO EXCEED 30Q OF A-TACHMENT PCINIS ON L-FEET OR 10" STANDOFFS. N FOR A SECOND ADDITIONAL INCH OF HEIGI IT va _ ADUYSTMENT,ADD ANOTHER �FVEDNG SPACER. USE DF I e -All TWO LEVELING SPACERS NOT _ I 0 EXCEED 100 OF Q2 _ 6 - ATTACHMENT POINTS ON { CFII L-FEET OR 10"STANDOFFS. RAIL HEIGHT(73.Q RAIL HEIGHT Q70 RAIL HEIGHT L3.C171 71 RAIL HEIGHT 05.0 ,i ABOVE ROOF SURFACES ABOVE ROOF SURFACE _ ABOVE ROOF SURFACE I�_ABOVE ROOF SURFACE`-ONE L FOOT ONE L FOOT ONE L FOOT "' ONE L FOOT F PLUS ONE SPACER " PLUS TWO SPACERS UNDER L FOOT UNDER.L FOOT MAINSI PG M ENERGY CORE DE6IGNER OMCPpCEICn NCAIE m PART NUMBER DESCRIPTION REV ti �� U Q�i - -• DRAFTER c Rr"" S100 DOS SERIES 100 RAIL LEVELING F LV LNI'os'[ionq 5$�.93¢d}ts _ _ AYPRUVEU BY UAIE kEVI51GN USE TILT KIT OPTION FOR INSTALLATIONS THAT REQUIRE MODULES TO BE TILTED ABOVE THE EXISTING ROOF SLOPE i SYSTEM SHOWN 15 DESIGNED FOR TILT ANGLES FROM 10 TO U DEGREES ABOVE ROOF SURFACE 4 l \ USE OF ANTI-SEIZE ON TILT HARDWARE IS RECOMMENDED(PARTICULARLY FOR MAX LENGTH: ®" 4 STAINLESS TO STAINLESS HARDWARE) WITH STANDARD .T ENGINEERING REFER TO 5100 TKT SERIES 170 TILT KIT TOOL FOR A SIMPLE TOOL THAT DRAMATICALLY SIMPLIFIES TILT KIT INSTALLATION BY — SNAPNRACK SUPPORTING THE UPPER RAIL AHEAD OF I RAIL STANDARD MODULE INSTALLATION SNAPPIRACK MID CLAMP ASSEMBLY CUT REAR TILT LEG FROM SCRAP OF STANDARD RAIL s " SNAPNRACK CHANNEL NUTS, TORQUE TO 10-16 FT-LBS WHEN SNAPHRACK L-FOOT USING WEEK&WHEN USING ALL-PURPOSE OP. SNAPNRACK BONDING CHANNEL 1 t, L-FOOT COMPOSMON NOTES: NUTS,TORQUE TO 1416 FT-LBS. WEEBS ARE NOT REQUIRED WITH f -TORQUE 16" HARDWARE TO THE FOLLOWING UNLESS OTHERWISE NOTED: BONDING CHANNEL NUTS. -SILVER S.S. 10-16 FT-LBS - BLACK S.S. 7-9 FT-LEIS - REFER TO ENGINEERING CHARTS FOR RAIL SPAN BASED ON MODULE TILT "X 1"(OR 1.25")S.S. BOLT ANGLE, WIND SPEED,AND SNOW LOAD - BACK SUPPORT"LEG"IS FABRICATED FROM A SCRAP OF RAIL.CALCULATE WITH SPLIT LOCK WASHER REQUIRED TILT LEG LENGTH. USE WEEB GROUNDING WASHERS AT®INTS BETWEEN L-FEET AND SNAPNRACK STANDARD RAIL SCRAP PIECE - FOR LOWER TILT APPLICATIONS SEE"SERIES 100 TILT KIT 0-15 DEG" -SNAPNRACK RAIL COVER CAN BE USED TO COVER CHANNEL IN REAR TILT LEG 5z��,-�n(��I7��, ,9 MAINY'TREAM ENERGY CORP DESIGNER GMNPheeters SCALE DNS PART NUMBER DESCRIPTION REV L' b°.u..)'MSO':JU�J& "'` ORAFTeR D R,., S100 010 SERIES IOU TILT KITS 1045 DEC WITH L 9T?lfk:t� .'�ayatw,= _ ..- APPROVWDe CAIE 120113 FOOT MOUNT F USE TILT KIT OPTION FOR INSTALLATIONS THAT REQUIRE MODULES TO BE TILTED ��4 ABOVE THE EXISTING ROOF SLOPE SYSTEM SHOWN IS DESIGNED FOR TILT ANGLES FROM 10 TO 13 DEGREES \ ABOVE ROOF SURFACE ON STANDING MAX LENT THt LB" ; SEAM METAL ROOFS WITH STANDARD \ SNAPNRACK USE OF ANTI-SEIZE ON TILT HARDWARE ENGINEERING ' RAIL STANDARD IS RECOMMENDED(PARTICULARLY FOR STAINLESS TO STAINLESS HARDWARE) y REFER TO S1D0 TKT SERIES 170 TILT KIT TOOL _ FOR A SIMPLE TOOL THAT DRAMATICALLY ' ' SIMPLIFIES TILT KIT INSTALLATION BY SNAPNACK CHANNEL NUTS, SNAPNRACK SUPPORTINGTHE UPPER RAIL AHEAD OF TORQUE TO 10-16 FT-LBS WHEN 1 CHANNEL NUT MODULE INSTALLATION USING WEEBS.WHEN USING SNAPNRACK BONDING CHANNEL YS5°X 1" (OR 1 25")S-S. BOLTS NUTS,TORQUE TO 14-16 FT-LBS. WITH SPLIT LOCK WASHERS W EEBS ARE NOT REQUIRED WITH BONDING CHANNEL NUTS. - \�\ CUT REAR TILT LEG FROM SCRAP �\ OF STANDARD RAIL NOTES: \~ SNAPNRACK SNAPNRACK SEAM CLAMP -TORQUE HARDWARE HARDWARE TO THE \, ' MID CLAMP ASSEMBLY WIDE OR STANDARD BASE FOI LOWING UNLESS OTHERWISE ~ NOTED: -SILVER S.S. 10-26 FT-LBS - BLACK S.S. 7-9 FT-LBS - REFER TO ENGINEERING CHARTS }\ FOR RAIL SPAN&ABED ON MODULE -f5" FLANGE NUT TILT ANGLE,WIND SPEED,AND a, SNOW LOAD L SNAPNRACK L FOOT ALL-PURPOSE - BACK SUPPORT"LEG"IS OR L FOOT COMPOSITION FABRICATED FROM A SCRAP OF n:"X 1"5,5. BOLT RAIL. CALCULATE REQUIRED TILT . WITH SPLIT LOCK WASHER LEG LENGTH. CUT RAIL AND DRILL TWO j" HOLES AS SHOWN SNAPNRACK SEAM CLAMP - FOR LOWER TILT APPLICATIONS WIDE OR STANDARD BASE SEE"SERIES 100 TILT KIT 0-15 ' DEG" X 1" (OR 1.25")S.S. 80LT i -SNAPNRACK RAIL COVER CAN BE WITH SPLIT LOCK WASHER USED TO COVER CHANNEL IN REAR TILT LEG �y:��� �/, ^ AMIN5TREAMENEP it �� DESIGNER GMCPnEs.l SCALE DNS PAPT 14UIABEP DESCRIPTION RE �J 7t'-4� ��I �`` � o�HeR G Ryan 5100 Dt1 SERIES 100 7lLT KITS 10-05 DEG SEAM APPROVED BY DATE 120113 Cl AMP MOUNT F NOTES: REVISION. -5/16" LAG BOLTS MUST EMBED 15"INTO ROOF STRUCTURAL MEMBERS/RAFTERS STEP 3: PLACE L FOOT -TORQUE ALL 5116"HARDWARE TO 014 TOP OF FLASHING SNAPNRACK THE FOLLOWING: AND TIGHTEN NUT COMPOSITION L FOOT -SILVER S.S. 10-16 FT-LBS CAN BE MOUNTED IN S.S. FLANGE NUT -BLACK S.S. 7-9 FT-LBS STEP 2: SLIP FLASHING OVER ANY ORIENTATION -RAILS CCT(MOUN ETO ITHENS ID E L FOOT BASE AND UNDER ROW X 1" OR 1.25") � OF SHINGLES ABOVE SNAPNRACK S.S. BOLT AND •�`' CHANNEL NUT SPLIT WASHER 1 S.S. LAG SCREW WITH FLAT WASHER SNAPNRACK 2 5"MINIMUM EMBEDMENT STANDARD RAIL - 15 STANDARD , SNAPNRACK COMPOSITION ROOF FLASHING STEP 1: BOLT L FOOT BASE TO ROOF WITH LAG BOLT SNAPNRACK L FOOT BASE ROOF DECKING TYP. ROOF DECKING TYP, FLASHED L FOOT MOUNTING POINT FOR USE ON COMPOSITION ROOF SURFACES WITH LOW TO MODERATE TILT RAILS CAN BE LEVELED UP TO 3"USING 1 UP TO TWO LEVELING SPACERS AS SHOWN IN"SERIES 100 RAIL LEVELING" COMPLETED INSTALLATION RAFTER TYP. WINSTREAM ENERGY CORP DESIGNER: 0WPhe%,e SCALE PART NUMBER: DESCRIPTION REV � i-p IC�J DNS PEN DETAIL 01,FLASHED L FOOT TO '.U.,Iit%ILI���,l .�+ � DRA=lER BRYan SI00 PEN 001 F 6f3umwfitp1foWYSg.0wSfR -,,. .., APPROVEDBY: GATE: 120113 RAFTER CAMMING SEAM CLAMPS ARE a_vislon SPECIFIED WITH A BLACK OXIDE STAINLESS STEEL BOLT. IT IS IMPORTANT TO USE THE PROVIDED BOLT AND TO TIGHTEN TO 16 FT-LBS FOR FULL LOAD CAPABILITY CLAMP CAN BE USED TO SECURE RAILS OR DIRECTLY SUPPORT SOLAR MODULES TO DETERMINE BOLT SIZE ADD WITH MODULE CLAMPS 1.17"TO THE"STACK"ON TOP OF THE CLAMP(X)AND ROUND UP TO NEAREST 7j'BOLT SI2E L FOOT OR SIMILAR TILT BRACKETS CAN BE ATTACHED TO THE TOP OF THE CLAMP AND PROVIDE A MOUNTING POINT FOR RAILS OR OTHER 3: BOLT IS STRUCTURAL MEMBERS TIGHTENED, SECURING CLAMP AND L D TORQUE BOLT FOOT AT THE TO 10-16 FT-LBS SAME TIME ,X„ SEAM CLAMP BASE _ I (STD BASE SHOWN ' BUT INSTALLATION - I OF WIDE BASE IS ` - SEAM _ IDENTICAL) CLAMP "` '4 CAM 2:OPEN 1 CLAMP GETS 1: INSTALLATION STARTS SEAM LOWERED .5 TYP. WITH CLAMP IN CLAMP ONTO SEAM OPEN POSITION _ THREAD WITH BOLT LOOSE INSERT f 1 2 3 O MAINSTREAM ENERGY CORP. DESIGNER: GWPMwte SCALE: DNS PART NUMBER'. DESCRIPTION' HEv [29�()1 ] DHAF&R DRy., DATE S100 PEN D04 FEN DETAIL04,SEAM CLAMP 120113 F L�fiS a^ w;zfdn N3,wo0scu ,,..,; APPROVED BY: , r r solar=oo SolarEdge Single Phase Inverters For North America SE3000A-US / SE3800A-US/ SE500OA-USISE6000A-US/ SE7600A US / SE10000A US SE11400A US : ♦V F�• � - � R k 4 � ttr 3 F f r e - f •,yL ie. ,� rx.iw . w a a p •rl�'r~ ��C' t �-d��"�,�, s �v �. The best choice for,SolarEdge enabled systems Integrated arc fault protection(Type 1)for NEC 2011 690.11 compliance _ — Superior efficiency(98%) M — Small,lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or wireless — Outdoor and indoor installation — Fixed voltage inverter,DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 U";I _r -R\Nrc •k:'AN ,I'IN d ,� E NErII 0ANDs Single Phase Inverters for North America solar=00 SE1(IfCA-I, 1_.NOOA ;S. A7,I CO A US SEGON A,-03 SE; 00A I jS SE;01"Ofl;A-Us S11- I W SE3110RIA-LIS 5EMOCIA-US SESOMA-US SE600OA-US SE750OA-135 SE10000A-US SE11400A-Us OUTPUT 01.1,'A '010 1800 t1u,H) 10"r) 1�20111 114,10 % 00(l) 3141) rA AL P.,,: »ijci I IWZ Al I. f,41, 21't- Mo 26,1 V", A, F,q,,,Min.III,n,.M. 99 1 Ir, [A)1,I tF[11 co pit 713- 00 G(%rj 16 >4 0 2,18V S J,2()S 'I7 g' zaov Grul rhrL,ho'd t A udiiy,murqoring, -,iandm '[I)Wt 10r,I OLMUV(�,r1fig,(.HhI� InwShOld.5 (Q5 yo INPUT T'I'millum DC [%T� dj'A! u)() 6750 d1110 .10<iu 13500 IST'D .d, 111,,Sf.111-1 less,ungrounded., ye5 ma,Input Voltage S00 vdc DC fl[;Ur 24"v Vd, NIx'.Innot(","t 9.5 B 113 23 ut j Lbr5 240V "a 2401, Max. pO Short�,mwt wr,ew R......e Pd,ntv Protection Yee G,Owld I.ilt Isolation DeL,cfion M,, ni*,"I ,Effc.in. 7 98.2 95.3 �11 �18 91 .9R 131t r. % EL We,,W ,;i owleow 42 f TS 20e V 11.5 91I.S I I Q -On' 9/,s 98�,D i,ov Sim 2,1111, W ADDITIONALFEATURES SuojkorlLd cuno11,rlkj a(](,;l 111terfaces R54E5,Rb232.E.homI t, ,iWe(,IpnmwI) F`enue rade uaLa ANlY I)_I Optional, Rapid shlllda.n-NE( 201469C.12 11,m S,i "'pia'hul d..,I I'd "'tH00, STANDARD COMPLIANCE SAety .,U,L474l, CSA.2;..2. C. (.�,,n,non IEEE;5A1 Emissions ___ FC C 11 nlb clas B INSTALLATION SPECIFICATIONS 3/4"wuvrn,,r 1 16 6 MPG 8 A,k:C 3M t...nimum L-2 .,rw,, AWG,a,,Cp, C 314 a....own,I i J stings x Lo 6AlVGA'A A 1P, 11, 94 1,15 In/ 7-,Sy i11Y.2A, R1111 51.2/23.2 54,1 j 74.1 98 A/4'D.Itb/Fg. Natural COmeUinn ioollmg N,1tI,[X(1,11,ctl, lnklmterfwt [a,f�, v I apiail,,10 fan(user ep;aceablel), Nose c2e <50 -IRA Nfi,;a NlLm 6 e" -13 to-140 -2r,to10 1 40 fc,i GO ver,ov ail,ible' I i C plotecn 11,PAT", 3R Play., II 1v T4 PIX 7,,z 144� 1-11 TIM '' '7 solar,=90 SolarEdge Power Optimizer ' Module Add-On For North America . P300 / P400 f P405 ,." ty 2 I pp "� . ag �F +.°� � g: � t«r,fa °�! :«r ,�*-' al-r •�. .ir 1�' -�!, loom ry ' y yFx a w y � � q AM � � x r F A• f d�� ° 1w 1 v PV power optimization at the,module- level Up to 25%more energy -.Superior efficiency(99.5%) �'- Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading " Flexible system design for maximum space utilization Fast installation with a single bolt Nextgeneration maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety U7A :ar, 1A;I In' tN [Hji%, SFAF 9il rR.'-Lif! L1 ,J,xr S'J E CCI; =:.lab solar - 3 s SolarEdge Power Optimizer Module Add-On for North America P300 / P400 / P405 P300 T P400 P405 (tar 6Ucell modules) {for 72,&96-c01 modules) (forthin film INPUT Rated l aput DC Pow_er"' -� 300 400 1105 W Ahcolate Maximum lr)put ,rrtage 48 80 125 Vdr (Vo( al luwesc temperatu_lc) _ _ ' MPPT OPerau rig Range ( 8 48 8 8o 12.S. 105 Vdc Maximum Shari (mcuir Clm aet(kc) 10 _Ad( Maxims m Dc.Inprn Current 12.5 y hdc Maximum Efficiency 99S ,. % OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Qi rerr[ 15 Adc -. .. .. _. ... .. .. .... .. . .. ... .. .. .. _.. _ Maximum Output voltage �_ _ 60 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) pu Saety Out t Voltage per Power Optimizer_T_ _ _ I. _�_Vdc _ STANDARD COMPLIANCE EMC FCC PaMS Clais B,IEC61000 G 2 IEC61000 6 . t ... ... ., .. , ... .. .. .. _ ... Safety CC621091(,Iassl safety),UL'1t41 Yes INSTALLATION SPECIFICATIONS Maximum Allowed.System Voltage _ 1000 .. Vdc Pxxx-2seli� L_4tx21 x7!).tijs y9xA?4e1S) rnm)ill Dimensions(W x L x HI 12Nx 152x1 5/ 8x152x 5 ! 129xi2 -4'S Pxxx-5 series mm/in xS97x lC4 Sx 5.9?<t 47. ,. _ 5x5.97x 1A9 , Weight(mciudmg cables) . Pxxx-2 series s0(2 1 _ IPxxx-5,series ...l. /70/ I7 9°0''205 930/2Oa I gr(1b nput Connector NIC4 Wnpahb1 . . .. ... Output e type Connector Opprating Temper'�titi Rare 005/30 .. .. 40 +851 70 r1951auol _ I 4Vu / ' DOUbl Insulat_d,Ni(4 Comp g. -�.. :Zr39 .. m/rt Protection Rating Pe.x 25ei es. ' - IP65/NEM1\4 Pxxx 5 series IPG4(N NIACP Relative Hunirdlry 0-100 r 96 'qme�E C�ra.var a!iOe mJult Mt c�ule u!up to..'.�+very mkran[e aunu.p PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTE_R(a tM ninon SCnng Length 2 8 I,0 18 (Power Ophrn 2NrtiJ. .I .. ... I ... .. .. Maximum Stri to Length -. ... .. 25 ZS fy 50 (power Optim' els) _ .. .. .. Maximum Power per String 5750 6060 ( -'12750 .. W„ .. ... ... ... , ... .. . ... Pardlel Strings of Different Lengths or0i lentatlons Yes sou1e.c c„oux onos+�nh vsooiraomr;ioiaxw r,e;ro�x. 4,1t,hr, Mono Multi Solutions r. _ EM mm PHE Universal Immm N, ) DaL.E I 60 CELL MULTICRYSTALLINE MODULE 245-26OW _ A05.08 POWER OUTPUT RANGE 15.9 Our root verslffa pfnduct MAXIMUM EFFICIENCY r -1 370 One of the indusiry's most trusted mcduies POWER OUTPUT GUARANTEE ,�,� • ^'F•,.-rcr^,u^'��"="^a^-= �, ,.,- _ienerorlun pr'cteaOgnic. "' - Highly reliable .1 u to stringent quahiy control r Deal 4 �, r _ertif d to withstand challenging enviran men to! . r. , r. , r •• � condltons - ?ir ^niil� l= l'? 1_ LbPC' LINEAR PERFORMANCE WARRANTY -- ---- --- -- --'--' — 70 Year Product Warranty • 25 Year Linear Power Warranty $ Natl7tro„a1 yG r /rom tin. rn� '�". ry+_ '�F~ M6 olaf f Idn9ar nYlgagry Trinasalar ° ° . ,.ur r'im r;r logevrer .. THE Universal MODULE TSM -P,405 Ufa DIMENSIONS Of" h1ODU1€ uilrnm 941 Peck Power Wpb-1 11(Wd 2J5 250 255 ^_oo Power Output Tolerance-P-1%) 0-3 m o-y �o btldmum Poyel Volfol(V) 29-9 30.3 30.5 30.6 Maxlmmn Power Current-U.,.=(A) 8.20 8.27 8.0> 8.50 Open GipeaC ul V011oye�V-: VI 32.3 38.0 38.1 38.2 1 I+"•ee Short C lc.t Current-i;r.(A) 8.75 8.79 8.88 90D H � Module @f tim(%) 15.0 15.3 15.6 IS.P _ 9 3£C kICA.C.1Tn IPA::'; Maximum Pavie'P"'(VIP) 182 160 190 193 Maximum Power Voltage-Vxn(V) 27..6 28.0 28.1 28.3 Me,nnum Power Current-Ir.-+=(Al 6.59 6.65 6.74 6.84 A Open Circuit Volt.gevoo(V) 35.1 35.2 35.3 35.4 /rm�"Tr Short Clrculi Conant-Lr[A( 7.07 7.1C 117 ]J r� +r:.r.:.. I $12 F 'y0 )tEC'h.9i11C F'.^AIL Solarcells MURU, ,talline I56-156mm(6lnchee( Cellorientalbn 60ce14(6.10) rE Mad.le dinwnaioiu 1650•992•051mn(6495.39.06-1.37 inches) I11IVIIniL�' Well 18.6kg(41.0Ibs) Glav 3.2mm(0.131ncnesl,Nigh Transmission,PR Coaled Tempered Glass ]c 1000 mm S Qckiheel While Forme 81ack Anocized AluntiniUm Alloy f3 J-Box IP 65 or[P Waded Cables Pholavalfalc Technology cable 4.0 mm210.006 incl roof100o mm 1,V CURIES Cf PV 61GDU Ig25Wj Conneclol MC4 or MC4C.dn;dp role 1 1- 4ik f Rh R>.P YGS vyPl `L - I{T'�� Tominol0 arafhl Call W kh product ,h,j, T.mPara Nre N10CT) W rkma sM1lp Wananfy 1 Temperature Coefficient of P.u.. -0.41%PC 25year Lnear Power Warranty Tenlperalule Caatfc'ent of Vo; -0.32851'C �•^•r s•o- -.. .z-•••t- w•,.. 5J01T1oT _ _ Temperature Coetri lent of Isc 0.05%/'C RT- to, ^J;" :4'1: .^La. \MPogr(t'1 rn:,,c1�.n�a+R�nNcc Operctianal Temperoture -40-165-C Maximum System •600VOC(Uy Voltage Mcs San.,FVsa Rating 15A CERTFICaTICnN t �� IB Sp• PA ;A(i1E1G Cz)tJ kGU8d PCU, - Lifill - m Nwddes ar bo' s pe:30 piece N \ ( Moddlesper40 contalner:840pleces E.�Ar Trinasl • u0 .;y.<Vl'.P�'.